Image not available
Illustrative purposes only
3RV2311-0GC20
Thermal Magnetic Circuit Breaker, SIRIUS 3RV2 Series, 630 mA, 3 Pole, 690 V, DIN Rail
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- No. of Poles: 3 Pole
- Product Range: SIRIUS 3RV2 Series
- Current Rating: 630mA
- Voltage Rating VAC: 690V
- Voltage Rating VDC: -
- Circuit Breaker Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 70.94 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2311-0GC20** **Data sheet** Circuit breaker size S00 for starter combination Rated current 0.63 A N-release 8.2 A Spring-type terminal Standard switching capacity |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For starter combinations| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S00| |**size of contactor can be combined company-specific**|S00, S0| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|5.5 W| |● at AC in hot operatingstateperpole|1.8 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP20| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|0.63 A| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|295g| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**type of voltage for main current circuit**|AC| |**operating voltage**|| |● rated value|690 V| |● rated value|20 ... 690 V| 3RV23110GC20 Page 1/5 Subject to change without notice © Copyright Siemens 5/31/2026 |● at AC-3 rated value maximum|690 V| |---|---| |● at AC-3e rated value maximum|690 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current rated value**|0.63 A| |**operational current**|| |● at AC-3 at 400 V rated value|0.63 A| |● at AC-3e at 400 V rated value|0.63 A| |**operating power**|| |● at AC-3|| |— at 230 V rated value|0.1 kW| |— at 400 V rated value|0.2 kW| |— at 500 V rated value|0.2 kW| |— at 690 V rated value|0.3 kW| |● at AC-3e|| |— at 230 V rated value|0.1 kW| |— at 400 V rated value|0.2 kW| |— at 500 V rated value|0.2 kW| |— at 690 V rated value|0.3 kW| |**operating frequency**|| |● at AC-3 maximum|15 1/h| |● at AC-3e maximum|15 1/h| |**Auxiliary circuit**|| |**type of voltage for auxiliary and control circuit**|AC/DC| |**number of NC contacts for auxiliary contacts**|0| |**number of NO contacts for auxiliary contacts**|0| |number of CO contacts for auxiliarycontacts|0| |**Protective and monitoring functions**|| |**product function**|| |●ground fault detection|No| |●phase failure detection|No| |**protection function thermal overloadprotection(ANSI 49)**|No| |**maximum short-circuit current breaking capacity (Icu)**|| |● at AC at 240 V rated value|100 kA| |● at AC at 400 V rated value|100 kA| |● at AC at 500 V rated value|100 kA| |● at AC at 690 V rated value|100 kA| |**operating short-circuit current breaking capacity (Ics) at AC**|| |● at 240 V rated value|100 kA| |● at 400 V rated value|100 kA| |● at 500 V rated value|100 kA| |● at 690 V rated value|100 kA| |response value current of instantaneous short-circuit trip unit|8.2 A| |**UL/CSA ratings**|| |**full-load current(FLA) for 3-phase AC motor**|| |● at 480 V rated value|0.63 A| |● at 600 V rated value|0.63 A| |**UL File Number(CCN)**|E47705(NLRV, NLRV7)| |**Short-circuit protection**|| |**product function short circuitprotection**|Yes| |**design of the short-circuit trip**|magnetic| |**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**|| |● at 690 V|gL/gG 6 A| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715| |**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes| 3RV23110GC20 Page 2/5 Subject to change without notice © Copyright Siemens 5/31/2026 |**height**|106 mm| |---|---| |**width**|45 mm| |**depth**|97 mm| |**required spacing**|| |● with side-by-side mounting|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— downwards|50 mm| |— at the side|0 mm| |● forgroundedparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— at the side|30 mm| |— downwards|50 mm| |● for liveparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— downwards|50 mm| |— at the side|30 mm| |● forgroundedparts at 400 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● for liveparts at 400 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● forgroundedparts at 500 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● for liveparts at 500 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● forgroundedparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|30 mm| |— forwards|0 mm| |● for liveparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|30 mm| |— forwards|0 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|No| |**type of electrical connection**|| |● for main current circuit|spring-loaded terminals| |**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom| |**type of connectable conductor cross-sections**|| |● for main contacts|| 3RV23110GC20 Page 3/5 Subject to change without notice © Copyright Siemens 5/31/2026 |— solid or stranded|— solid or stranded|2x(0,5 ... 4 mm²)| |---|---|---| |— finelystranded with core endprocessing||2x(0.5 ... 2.5 mm²)| |— finelystranded without core endprocessing||2x(0.5 ... 2.5 mm²)| |● for AWG cables for main contacts||2x(20 ... 12)| |**connectable conductor cross-section for main contacts**||| |● solid or stranded||0.5 ... 4 mm²| |● finelystranded with core endprocessing||0.5 ... 2.5 mm²| |● finelystranded without core endprocessing||0.5 ... 2.5 mm²| |**AWG number as coded connectable conductor cross**<br>**section for main contacts**||20 ... 12| |**design of screwdriver shaft**<br>~~———~~||Diameter 3 mm<br>~~———~~| |**size of the screwdriver tip**<br>~~———~~||3,0 x 0,5 mm<br>~~———~~| |**Safety related data**<br>~~———~~||| |product function suitable for safetyfunction<br>~~———~~||Yes<br>~~———~~| |**suitability for use**||| |● safety-related switchingon||No| |● safety-related switchingOFF||Yes| |**service life maximum**||10 a| |**test wear-related service life necessary**||Yes| |**proportion of dangerous failures**||| |● with low demand rate accordingto SN 31920||40 %| |● with high demand rate accordingto SN 31920||50 %| |**B10 value with high demand rate according to SN 31920**||5 000| |**failure rate [FIT] with low demand rate according to SN**<br>**31920**<br>~~ee~~||50 FIT<br>~~ee~~| |ISO 13849<br>~~ee~~||| |**device type according to ISO 13849-1**<br>~~ee~~<br>~~SS~~||3<br>~~ee~~<br>~~SS~~| |**overdimensioning according to ISO 13849-2 necessary**<br>~~SS~~||Yes<br>~~SS~~| |IEC 61508<br>~~SS~~||| |**safety device type according to IEC 61508-2**<br>~~SS~~||Type A<br>~~SS~~| |**T1 value**||| |● for proof test interval or service life according to IEC<br>61508<br>~~ee~~||10 a<br>~~ee~~| |Electrical Safety<br>~~ee~~||| |**protection class IP on the front according to IEC 60529**<br>~~ee~~||IP20<br>~~ee~~| |**touch protection on the front according to IEC 60529**||finger-safe, for vertical contact from the front| |**Display**<br>~~|~~||| |displayversion for switchingstatus<br>~~|~~||Handle<br>~~|~~| |**Approvals Certificates**<br>~~ee~~||| |**Environment**<br>~~ee~~|**General Product Approval**<br>~~ee~~|| ~~ee~~ **Approvals Certificates Environment General Product Approval** Environmental Confirmations **General Product Approval** ## **Test Certificates** **Maritime application** |Special Test Certific-<br>ate|Type Test Certific-<br>ates/Test Report| |---|---| ||**other**| ||Confirmation<br>~~~~~| 3RV23110GC20 Page 4/5 Subject to change without notice © Copyright Siemens 5/31/2026 **other Railway** Miscellaneous Confirmation Miscellaneous Confirmation Special Test Certificate ~~_ _ ss~~ | an ert ~~rs~~ ~~OO—C™rSC“‘CNCéiéCs~~ **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2311-0GC20 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2311-0GC20 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2311-0GC20&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2311-0GC20 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **==> picture [263 x 335] intentionally omitted <==** **----- Start of picture text -----**<br> -F<br>||<br>ae<br>I> I> I><br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3<br>2 4 6<br>**----- End of picture text -----**<br> **last modified:** 5/5/2026 3RV23110GC20 Page 5/5 Subject to change without notice © Copyright Siemens 5/31/2026
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →