3RV2311-0FC20
Thermal Magnetic Circuit Breaker, SIRIUS 3RV2 Series, 500 mA, 3 Pole, 690 V, DIN Rail
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- No. of Poles: 3 Pole
- Product Range: SIRIUS 3RV2 Series
- Current Rating: 500mA
- Voltage Rating VAC: 690V
- Voltage Rating VDC: -
- Circuit Breaker Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 69.31 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2311-0FC20** **Data sheet** Circuit breaker size S00 for starter combination Rated current 0.5 A N-release 6.5 A Spring-type terminal Standard switching capacity |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For starter combinations| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S00| |**size of contactor can be combined company-specific**|S00, S0| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|5.5 W| |● at AC in hot operatingstateperpole|1.8 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP20| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|0.5 A| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|300g| |**Ambient conditions**|| 3RV23110FC20 Page 1/7 Subject to change without notice © Copyright Siemens 6/2/2026 ||installation altitude at height above sea level maximum|2 000 m|| |---|---|---|---| ||**ambient temperature**||| ||● duringoperation|-20 ... +60 °C|| ||● duringstorage|-50 ... +80 °C|| ||● duringtransport|-50 ... +80 °C|| ||relative humidityduringoperation|10 ... 95 %|| ||**Main circuit**||| ||**number ofpoles for main current circuit**|3|| ||**type of voltage for main current circuit**|AC|| ||**operating voltage**||| ||● rated value|690 V|| ||● rated value|20 ... 690 V|| ||● at AC-3 rated value maximum|690 V|| ||● at AC-3e rated value maximum|690 V|| ||**operating frequency rated value**|50 ... 60 Hz|| ||**operational current rated value**|0.5 A|| ||**operational current**||| ||● at AC-3 at 400 V rated value|0.5 A|| ||● at AC-3e at 400 V rated value|0.5 A|| ||**operating power**||| ||● at AC-3||| ||— at 230 V rated value|0.1 kW|| ||— at 400 V rated value|0.1 kW|| ||— at 500 V rated value|0.1 kW|| ||— at 690 V rated value|0.2 kW|| ||● at AC-3e||| ||— at 230 V rated value|0.1 kW|| ||— at 400 V rated value|0.1 kW|| ||— at 500 V rated value|0.1 kW|| ||— at 690 V rated value|0.2 kW|| ||**operating frequency**||| ||● at AC-3 maximum|15 1/h|| ||● at AC-3e maximum|15 1/h|| ||**Auxiliary circuit**||| ||**type of voltage for auxiliary and control circuit**|AC/DC|| ||**number of NC contacts for auxiliary contacts**|0|| ||**number of NO contacts for auxiliary contacts**|0|| ||number of CO contacts for auxiliarycontacts|0|| ||**Protective and monitoring functions**||| ||**product function**||| ||●ground fault detection|No|| ||●phase failure detection|No|| ||**protection function thermal overloadprotection(ANSI 49)**|No|| ||**maximum short-circuit current breaking capacity (Icu)**||| ||● at AC at 240 V rated value|100 kA|| ||● at AC at 400 V rated value|100 kA|| ||● at AC at 500 V rated value|100 kA|| ||● at AC at 690 V rated value|100 kA|| ||**operating short-circuit current breaking capacity (Ics) at AC**||| ||● at 240 V rated value|100 kA|| ||● at 400 V rated value|100 kA|| ||● at 500 V rated value|100 kA|| ||● at 690 V rated value|100 kA|| ||response value current of instantaneous short-circuit trip unit|6.5 A|| ||**UL/CSA ratings**||| ||**full-load current(FLA) for 3-phase AC motor**||| ||● at 480 V rated value|0.5 A|| ||● at 600 V rated value|0.5 A|| ||**UL File Number (CCN)**|E47705 (NLRV, NLRV7)|| 3RV23110FC20 Page 2/7 Subject to change without notice © Copyright Siemens 6/2/2026 ||**Short-circuit protection**|**Short-circuit protection**|| |---|---|---|---| ||**product function short circuitprotection**|Yes|| ||**design of the short-circuit trip**|magnetic|| ||**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**||| ||● at 690 V|gL/gG 4 A|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|| ||**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes|| ||**height**|106 mm|| ||**width**|45 mm|| ||**depth**|97 mm|| ||**required spacing**||| ||● with side-by-side mounting||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|0 mm|| ||● forgroundedparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— at the side|30 mm|| ||— downwards|50 mm|| ||● for liveparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|30 mm|| ||● forgroundedparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||● for liveparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| 3RV23110FC20 Page 3/7 Subject to change without notice © Copyright Siemens 6/2/2026 **==> picture [512 x 681] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |— at the side|30 mm| |— forwards|0 mm| |||Connections/ Terminals| |product component removable terminal for auxiliary and|No| |control circuit| |type of electrical connection| |● for main current circuit|spring-loaded terminals| |arrangement of electrical connectors for main current|Top and bottom| |circuit| |type of connectable conductor cross-sections| |● for main contacts| |— solid or stranded|2x (0,5 ... 4 mm²)| |— finely stranded with core end processing|2x (0.5 ... 2.5 mm²)| |— finely stranded without core end processing|2x (0.5 ... 2.5 mm²)| |● for AWG cables for main contacts|2x (20 ... 12)| |connectable conductor cross-section for main contacts| |● solid or stranded|0.5 ... 4 mm²| |● finely stranded with core end processing|0.5 ... 2.5 mm²| |● finely stranded without core end processing|0.5 ... 2.5 mm²| |AWG number as coded connectable conductor cross|20 ... 12| |section for main contacts| |design of screwdriver shaft|Diameter 3 mm| |Oo| |size of the screwdriver tip|3,0 x 0,5 mm| |Safety related data| |product function suitable for safety function|Yes| |suitability for use| |● safety-related switching on|No| |● safety-related switching OFF|Yes| |service life maximum|10 a| |test wear-related service life necessary|Yes| |proportion of dangerous failures| |● with low demand rate according to SN 31920|40 %| |● with high demand rate according to SN 31920|50 %| |B10 value with high demand rate according to SN 31920|5 000| |failure rate [FIT] with low demand rate according to SN|50 FIT| |31920| |a|ISO 13849| |device type according to ISO 13849-1|3| |overdimensioning according to ISO 13849-2 necessary|Yes| |IEC 61508| |OOOO| |safety device type according to IEC 61508-2|Type A| |T1 value| |● for proof test interval or service life according to IEC|10 a| |61508| |OOOO|Electrical Safety| |protection class IP on the front according to IEC 60529|IP20| |touch protection on the front according to IEC 60529|finger-safe, for vertical contact from the front| |||Display| |display version for switching status|Handle| |ee|Approvals Certificates| |Environment|General Product Approval| |Environmental Con-| |firmations| |sa|ge|@|[@|Ef| **----- End of picture text -----**<br> **Test Certificates** **General Product Approval** 3RV23110FC20 Page 4/7 Subject to change without notice © Copyright Siemens 6/2/2026 - - Special Test Certific Type Test Certific ate ates/Test Report ## **Maritime application** **other Railway** Miscellaneous Confirmation Miscellaneous Special Test CertificConfirmation ate QC PASS ~~es e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2311-0FC20 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2311-0FC20 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2311-0FC20&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2311-0FC20 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> 3RV23110FC20 Page 5/7 Subject to change without notice © Copyright Siemens 6/2/2026 **==> picture [511 x 718] intentionally omitted <==** 3RV23110FC20 Page 6/7 Subject to change without notice © Copyright Siemens 6/2/2026 **==> picture [343 x 368] intentionally omitted <==** **----- Start of picture text -----**<br> -F<br>|||<br>|||<br>I> I> I><br>last modified: 5/5/2026 g<br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3<br>2 4 6<br>**----- End of picture text -----**<br> 3RV23110FC20 Page 7/7 Subject to change without notice © Copyright Siemens 6/2/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →