Thermal Magnetic Circuit Breaker, MPCB, 3RV2, 3P, 65 kA, 400 V, 65 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 343.11 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2131-4JA10** **Data sheet** circuit breaker size S2 for motor protection, Class 10 with overload relay function thermal release 54...65 A short-circuit release 845 A screw terminal standard switching capacity |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection with overload relayfunction| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S2| |**size of contactor can be combined company-specific**|S2| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|26 W| |● at AC in hot operatingstateperpole|8.7 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP00| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms Sinus| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|20 000| |● of auxiliarycontacts typical|20 000| |electrical endurance(operatingcycles)typical|20 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|65 A| |**Substance Prohibitance(day/month/year)**|03/01/2017| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|1.241 kg| |**Ambient conditions**|| Subject to change without notice © Copyright Siemens 3RV21314JA10 Page 1/7 5/30/2026 |installation altitude at height above sea level maximum|2 000 m| |---|---| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**<br>**dependent overload release**|54 ... 65 A| |**type of voltage for main current circuit**|AC| |**operating voltage**|| |● rated value|690 V| |● rated value|20 ... 690 V| |● at AC-3 rated value maximum|690 V| |● at AC-3e rated value maximum|690 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current rated value**|65 A| |**operational current**|| |● at AC-3 at 400 V rated value|65 A| |● at AC-3e at 400 V rated value|65 A| |**operating power**|| |● at AC-3|| |— at 230 V rated value|18.5 kW| |— at 400 V rated value|30 kW| |— at 500 V rated value|45 kW| |— at 690 V rated value|55 kW| |● at AC-3e|| |— at 230 V rated value|18.5 kW| |— at 400 V rated value|30 kW| |— at 500 V rated value|45 kW| |— at 690 V rated value|55 kW| |**operating frequency**|| |● at AC-3 maximum|15 1/h| |● at AC-3e maximum|15 1/h| |**Auxiliary circuit**|| |**design of the auxiliary switch**|laterally| |**type of voltage for auxiliary and control circuit**|AC/DC| |**number of NC contacts for auxiliary contacts**|0| |**number of NO contacts for auxiliary contacts**|0| |number of CO contacts for auxiliarycontacts|0| |**Protective and monitoring functions**|| |**product function**|| |●ground fault detection|No| |●phase failure detection|Yes| |**trip class**|CLASS 10| |**design of the overload release**|thermal| |**protection function thermal overloadprotection(ANSI 49)**|Yes| |**maximum short-circuit current breaking capacity (Icu)**|| |● at AC at 240 V rated value|65 kA| |● at AC at 400 V rated value|65 kA| |● at AC at 500 V rated value|8 kA| |● at AC at 690 V rated value|4 kA| |**operating short-circuit current breaking capacity (Ics) at AC**|| |● at 240 V rated value|100 kA| |● at 400 V rated value|30 kA| |● at 500 V rated value|5 kA| |● at 690 V rated value|2 kA| Subject to change without notice © Copyright Siemens 3RV21314JA10 Page 2/7 5/30/2026 ||response value current of instantaneous short-circuit trip unit|845 A|| |---|---|---|---| ||**UL/CSA ratings**||| ||**full-load current(FLA) for 3-phase AC motor**||| ||● at 480 V rated value|65 A|| ||● at 600 V rated value|62 A|| ||**yielded mechanicalperformance[hp]**||| ||● for 3-phase AC motor||| ||— at 200/208 V rated value|20 hp|| ||— at 220/230 V rated value|25 hp|| ||— at 460/480 V rated value|50 hp|| ||— at 575/600 V rated value|60 hp|| ||**Short-circuit protection**||| ||**product function short circuitprotection**|Yes|| ||**design of the short-circuit trip**|magnetic|| ||**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**||| ||● at 240 V|none required|| ||● at 400 V|160|| ||● at 500 V|125|| ||● at 690 V|100|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|| ||**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes|| ||**height**|140 mm|| ||**width**|75 mm|| ||**depth**|149 mm|| ||**required spacing**||| ||● with side-by-side mounting||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|0 mm|| ||● forgroundedparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— at the side|10 mm|| ||— downwards|50 mm|| ||● for liveparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|10 mm|| ||● forgroundedparts at 400 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— at the side|10 mm|| ||● for liveparts at 400 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— at the side|10 mm|| ||● forgroundedparts at 500 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— at the side|10 mm|| Subject to change without notice © Copyright Siemens 3RV21314JA10 Page 3/7 5/30/2026 |● for liveparts at 500 V|| |---|---| |— downwards|50 mm| |— upwards|50 mm| |— at the side|10 mm| |● forgroundedparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|10 mm| |— forwards|0 mm| |● for liveparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|10 mm| |— forwards|0 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|No| |**type of electrical connection**|| |● for main current circuit|screw-type terminals| |● for auxiliaryand control circuit|screw-type terminals| |**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom| |**type of connectable conductor cross-sections**|| |● for main contacts|| |— solid or stranded|2x(1 ... 35 mm²), 1x(1 ... 50 mm²)| |— finelystranded with core endprocessing|2x(1 ... 25 mm²), 1x(1 ... 35 mm²)| |● for AWG cables for main contacts|2x(18 ... 2), 1x(18 ... 1)| |**connectable conductor cross-section for main contacts**|| |● solid or stranded|1 ... 50 mm²| |● finelystranded with core endprocessing|1 ... 35 mm²| |**AWG number as coded connectable conductor cross**<br>**section for main contacts**|18 ... 1| |**tightening torque**|| |● for main contacts with screw-type terminals|3 ... 4.5 N·m| |● for auxiliarycontacts with screw-type terminals|0.8 ... 1.2 N·m| |**design of screwdriver shaft**|Diameter 5 to 6 mm| |**size of the screwdriver tip**|Pozidriv size 2| |**design of the thread of the connection screw**|| |● for main contacts|M6| |● of the auxiliaryand control contacts|M3| |**Safety related data**|| |product function suitable for safetyfunction|Yes| |**suitability for use**|| |● safety-related switchingon|No| |● safety-related switchingOFF|Yes| |**service life maximum**|10 a| |**test wear-related service life necessary**|Yes| |**proportion of dangerous failures**|| |● with low demand rate accordingto SN 31920|40 %| |● with high demand rate accordingto SN 31920|50 %| |**B10 value with high demand rate according to SN 31920**|5 000| |**failure rate [FIT] with low demand rate according to SN**<br>**31920**|50 FIT| |ISO 13849|| |**device type according to ISO 13849-1**|3| |**overdimensioning according to ISO 13849-2 necessary**|Yes| |IEC 61508|| |**safety device type according to IEC 61508-2**|Type A| Subject to change without notice © Copyright Siemens 3RV21314JA10 Page 4/7 5/30/2026 ## **T1 value** |**T1 value**|| |---|---| |● for proof test interval or service life according to IEC<br>61508<br>~~ee~~|10 a<br>~~ee~~| |Electrical Safety<br>~~ee~~|| |**protection class IP on the front according to IEC 60529**<br>~~ee~~|IP20<br>~~ee~~| |**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front| |**Display**<br>~~ee~~|| |displayversion for switchingstatus<br>~~ee~~|Handle<br>~~ee~~| |**Approvals Certificates**<br>~~a~~|| |Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing<br>12.8 kg<br>● global warming potential [CO2 eq] / during sales<br>0.477 kg<br>● global warming potential [CO2 eq] / during operation<br>230 kg<br>● global warming potential [CO2 eq] / after end of life<br>-3.4 kg<br>● global warming potential [CO2 eq] / total<br>239.877 kg<br>**Environment**<br>**General Product Approval**<br>~~a~~|| Environmental Confirmations ~~_~~ @ @ **General Product Approval Test Certificates** - - Special Test Certific Type Test Certific ate ates/Test Report EAL a) **Maritime application** **other Railway** Confirmation Miscellaneous Confirmation Miscellaneous Special Test Certificate QC PASS ~~rr:~~ **Railway** Confirmation ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2131-4JA10 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2131-4JA10 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** Subject to change without notice © Copyright Siemens 3RV21314JA10 Page 5/7 5/30/2026 https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2131-4JA10&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2131-4JA10 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **==> picture [203 x 225] intentionally omitted <==** Subject to change without notice © Copyright Siemens 3RV21314JA10 Page 6/7 5/30/2026 **==> picture [411 x 360] intentionally omitted <==** **----- Start of picture text -----**<br> TEST<br>|<br>|<br>-F<br>| [|]<br>| [|]<br>I> I> I><br>last modified: 5/5/2026 g<br>1/L1 3/L2 5/L3 95 97<br>1T 2T 3T 96 98<br>2/ 4/ 6/<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3RV21314JA10 Page 7/7 5/30/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →