Image not available
Illustrative purposes only
3RV2023-4CA20
Thermal Magnetic Circuit Breaker, MPCB, 3RV2, 3P, 55 kA, 400 V, 22 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 98.25 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2023-4CA20** **Data sheet** circuit breaker frame size S0 for motor protection, Class 10 thermal overload release 16…22 A short-circuit release 286 A spring-loaded terminal switching capacity 30 kA at 600 V according to UL/CSA |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S0| |**size of contactor can be combined company-specific**|S00, S0| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|10.5 W| |● at AC in hot operatingstateperpole|3.5 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP20| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|22 A| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**Net Weight**|0.414 kg| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**|16 ... 22 A| |**dependent overload release**|| |**type of voltage for main current circuit**|AC| |**operating voltage**|| 3RV20234CA20 Page 1/5 Subject to change without notice © Copyright Siemens 5/30/2026 |● rated value|690 V| |---|---| |● rated value|20 ... 690 V| |● at AC-3 rated value maximum|690 V| |● at AC-3e rated value maximum|690 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current rated value**|22 A| |**operational current**|| |● at AC-3 at 400 V rated value|22 A| |● at AC-3e at 400 V rated value|22 A| |**operating power**|| |● at AC-3|| |— at 690 V rated value|18.5 kW| |● at AC-3e|| |— at 690 V rated value|18.5 kW| |**operating frequency**|| |● at AC-3 maximum|15 1/h| |● at AC-3e maximum|15 1/h| |**Auxiliary circuit**|| |**type of voltage for auxiliary and control circuit**|AC/DC| |**number of NC contacts for auxiliary contacts**|0| |**number of NO contacts for auxiliary contacts**|0| |number of CO contacts for auxiliarycontacts|0| |**Protective and monitoring functions**|| |**product function**|| |●ground fault detection|No| |●phase failure detection|Yes| |**trip class**|CLASS 10| |**design of the overload release**|thermal| |**protection function thermal overloadprotection(ANSI 49)**|Yes| |**maximum short-circuit current breaking capacity (Icu)**|| |● at AC at 690 V rated value|4 kA| |**operating short-circuit current breaking capacity (Ics) at AC**|| |● at 690 V rated value|2 kA| |response value current of instantaneous short-circuit trip unit|286 A| |**UL/CSA ratings**|| |**full-load current(FLA) for 3-phase AC motor**|| |● at 480 V rated value|22 A| |● at 600 V rated value|22 A| |**yielded mechanicalperformance[hp]**|| |● for single-phase AC motor|| |— at 110/120 V rated value|1.5 hp| |— at 230 V rated value|3 hp| |● for 3-phase AC motor|| |— at 200/208 V rated value|7.5 hp| |— at 220/230 V rated value|7.5 hp| |— at 460/480 V rated value|15 hp| |— at 575/600 V rated value|20 hp| |**UL File Number(CCN)**|E47705(NLRV, NLRV7)| |**Short-circuit protection**|| |**product function short circuitprotection**|Yes| |**design of the short-circuit trip**|magnetic| |**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**|| |● at 400 V|gG 63 A| |● at 500 V|gG 50 A| |● at 690 V|gG 50 A| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715| 3RV20234CA20 Page 2/5 Subject to change without notice © Copyright Siemens 5/30/2026 |**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes| |---|---| |**height**|119 mm| |**width**|45 mm| |**depth**|97 mm| |**required spacing**|| |● with side-by-side mounting|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— downwards|50 mm| |— at the side|0 mm| |● forgroundedparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— at the side|30 mm| |— downwards|50 mm| |● for liveparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— downwards|50 mm| |— at the side|30 mm| |● forgroundedparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— at the side|30 mm| |● for liveparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— at the side|30 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|No| |**type of electrical connection**|| |● for main current circuit|spring-loaded terminals| |**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom| |**type of connectable conductor cross-sections**|| |● for main contacts|| |— solid or stranded|2x(1 ... 10 mm²)| |— finelystranded with core endprocessing|2x(1 ... 6 mm²)| |— finelystranded without core endprocessing|2x(1 ... 6 mm²)| |● for AWG cables for main contacts|2x(18 ... 8)| |**connectable conductor cross-section for main contacts**|| |● solid or stranded|1 ... 10 mm²| |● finelystranded with core endprocessing|1 ... 6 mm²| |● finelystranded without core endprocessing|1 ... 6 mm²| |**AWG number as coded connectable conductor cross**<br>**section for main contacts**|18 ... 8| |**design of screwdriver shaft**|Diameter 3 mm| |**size of the screwdriver tip**|3,0 x 0,5 mm| |**Safety related data**|| |product function suitable for safetyfunction|Yes| |**suitability for use**|| |● safety-related switchingon|No| |● safety-related switchingOFF|Yes| |**service life maximum**|10 a| 3RV20234CA20 Page 3/5 Subject to change without notice © Copyright Siemens 5/30/2026 |**test wear-related service life necessary**|Yes| |---|---| |**proportion of dangerous failures**|| |● with low demand rate accordingto SN 31920|40 %| |● with high demand rate accordingto SN 31920|50 %| |**B10 value with high demand rate according to SN 31920**|5 000| |**failure rate [FIT] with low demand rate according to SN**<br>**31920**<br>~~ee~~|50 FIT<br>~~ee~~| |ISO 13849<br>~~ee~~|| |**device type according to ISO 13849-1**<br>~~ee~~<br>~~by~~|3<br>~~ee~~<br>~~by~~| |**overdimensioning according to ISO 13849-2 necessary**<br>~~by~~|Yes<br>~~by~~| |IEC 61508<br>~~by~~|| |**safety device type according to IEC 61508-2**<br>~~by~~|Type A<br>~~by~~| |**T1 value**|| |● for proof test interval or service life according to IEC<br>61508<br>~~ee~~|10 a<br>~~ee~~| |Electrical Safety<br>~~ee~~|| |**protection class IP on the front according to IEC 60529**<br>~~ee~~|IP20<br>~~ee~~| |**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front| |**Display**<br>~~ee~~|| |displayversion for switchingstatus<br>~~ee~~|Handle<br>~~ee~~| |**Approvals Certificates**<br>~~————~~|| |Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing<br>2.68 kg<br>● global warming potential [CO2 eq] / during sales<br>0.143 kg<br>● global warming potential [CO2 eq] / during operation<br>72.7 kg<br>● global warming potential [CO2 eq] / after end of life<br>-0.445 kg<br>● global warming potential [CO2 eq] / total<br>75.078 kg<br>**Environment**<br>**General Product Approval**<br>~~————~~|| |Environmental Con-|||||| |---|---|---|---|---|---| |firmations|||||| ||||||| |**General Product Approval**|||**Test Certificates**||**Maritime application**| |||VK|Special Test Certific-<br>ate<br>~~— ——_~~|Type Test Certific-<br>ates/Test Report<br> ~~—~~|| |**Maritime application**|||||**other**| |pene|ow|Regis<br>is|®<br>#|L|Miscellaneous<br>ee| |**other**|||**Railway**||| |Confirmation<br>~~—~~|Miscellaneous<br>~~—~~||Confirmation|Special Test Certific-|| |||||ate|| **Further information** ~~ee~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** 3RV20234CA20 Page 4/5 Subject to change without notice © Copyright Siemens 5/30/2026 https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2023-4CA20 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2023-4CA20 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2023-4CA20&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2023-4CA20 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **==> picture [263 x 335] intentionally omitted <==** **----- Start of picture text -----**<br> -F<br>|||<br>|||<br>I> I> I><br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3<br>2 4 6<br>**----- End of picture text -----**<br> **last modified:** 5/5/2026 3RV20234CA20 Page 5/5 Subject to change without notice © Copyright Siemens 5/30/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →