- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 100.92 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2021-1GA25** **Data sheet** circuit breaker frame size S0 for motor protection, Class 10 thermal release 4.5...6.3 A short-circuit release 82 A spring-loaded terminal standard switching capacity with transverse auxiliary switch 1 NO+1 NC |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S0| |**size of contactor can be combined company-specific**|S00, S0| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|7.25 W| |● at AC in hot operatingstateperpole|2.4 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP20| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|6.3 A| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|427g| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**|4.5 ... 6.3 A| |**dependent overload release**|| |**type of voltage for main current circuit**|AC| 3RV20211GA25 Page 1/6 Subject to change without notice © Copyright Siemens 5/30/2026 ||**operating voltage**||| |---|---|---|---| ||● rated value|690 V|| ||● rated value|20 ... 690 V|| ||● at AC-3 rated value maximum|690 V|| ||● at AC-3e rated value maximum|690 V|| ||**operating frequency rated value**|50 ... 60 Hz|| ||**operational current rated value**|6.3 A|| ||**operational current**||| ||● at AC-3 at 400 V rated value|6.3 A|| ||● at AC-3e at 400 V rated value|6.3 A|| ||**operating power**||| ||● at AC-3||| ||— at 230 V rated value|1.5 kW|| ||— at 400 V rated value|2.2 kW|| ||— at 500 V rated value|3 kW|| ||— at 690 V rated value|4 kW|| ||● at AC-3e||| ||— at 230 V rated value|1.5 kW|| ||— at 400 V rated value|2.2 kW|| ||— at 500 V rated value|3 kW|| ||— at 690 V rated value|4 kW|| ||**operating frequency**||| ||● at AC-3 maximum|15 1/h|| ||● at AC-3e maximum|15 1/h|| ||**Auxiliary circuit**||| ||**design of the auxiliary switch**|transverse|| ||**type of voltage for auxiliary and control circuit**|AC/DC|| ||**number of NC contacts for auxiliary contacts**|1|| ||**number of NO contacts for auxiliary contacts**|1|| ||number of CO contacts for auxiliarycontacts|0|| ||**operational current of auxiliary contacts at AC-15**||| ||● at 24 V|2 A|| ||● at 120 V|0.5 A|| ||● at 125 V|0.5 A|| ||● at 230 V|0.5 A|| ||**operational current of auxiliary contacts at DC-13**||| ||● at 24 V|1 A|| ||● at 60 V|0.15 A|| ||**Protective and monitoring functions**||| ||**product function**||| ||●ground fault detection|No|| ||●phase failure detection|Yes|| ||**trip class**|CLASS 10|| ||**design of the overload release**|thermal|| ||**protection function thermal overloadprotection(ANSI 49)**|Yes|| ||**maximum short-circuit current breaking capacity (Icu)**||| ||● at AC at 240 V rated value|100 kA|| ||● at AC at 400 V rated value|100 kA|| ||● at AC at 500 V rated value|100 kA|| ||● at AC at 690 V rated value|6 kA|| ||**operating short-circuit current breaking capacity (Ics) at AC**||| ||● at 240 V rated value|100 kA|| ||● at 400 V rated value|100 kA|| ||● at 500 V rated value|100 kA|| ||● at 690 V rated value|4 kA|| ||response value current of instantaneous short-circuit trip unit|82 A|| ||**UL/CSA ratings**||| ||**full-load current(FLA) for 3-phase AC motor**||| ||● at 480 V rated value|6.3 A|| 3RV20211GA25 Page 2/6 Subject to change without notice © Copyright Siemens 5/30/2026 ||● at 600 V rated value|6.3 A|| |---|---|---|---| ||**yielded mechanicalperformance[hp]**||| ||● for single-phase AC motor||| ||— at 110/120 V rated value|0.25 hp|| ||— at 230 V rated value|0.5 hp|| ||● for 3-phase AC motor||| ||— at 200/208 V rated value|1 hp|| ||— at 220/230 V rated value|1.5 hp|| ||— at 460/480 V rated value|3 hp|| ||— at 575/600 V rated value|5 hp|| ||**contact rating of auxiliary contacts according to UL**|C300 / R300|| ||**UL File Number(CCN)**|E47705(NLRV, NLRV7), E156943(NKJH, NKJH7)|| ||**Short-circuit protection**||| ||**product function short circuitprotection**|Yes|| ||**design of the short-circuit trip**|magnetic|| ||**design of the fuse link**||| ||● for short-circuit protection of the auxiliary switch required|Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400<br>A)|| ||certificate of suitabilityaccordingto ATEX directive 2014/34/EU|DMT 02 ATEX F 001|| ||**type of protection according to ATEX directive 2014/34/EU**|Ex II(2)GD|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|| ||**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes|| ||**height**|119 mm|| ||**width**|45 mm|| ||**depth**|97 mm|| ||**required spacing**||| ||● with side-by-side mounting||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|0 mm|| ||● forgroundedparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— at the side|30 mm|| ||— downwards|50 mm|| ||● for liveparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|30 mm|| ||● forgroundedparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| 3RV20211GA25 Page 3/6 Subject to change without notice © Copyright Siemens 5/30/2026 |● for liveparts at 500 V|| |---|---| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● forgroundedparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|30 mm| |— forwards|0 mm| |● for liveparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|30 mm| |— forwards|0 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|No| |**type of electrical connection**|| |● for main current circuit|spring-loaded terminals| |● for auxiliaryand control circuit|spring-loaded terminals| |**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom| |**type of connectable conductor cross-sections**|| |● for main contacts|| |— solid or stranded|2x(1 ... 10 mm²)| |— finelystranded with core endprocessing|2x(1 ... 6 mm²)| |— finelystranded without core endprocessing|2x(1 ... 6 mm²)| |● for AWG cables for main contacts|2x(18 ... 8)| |**connectable conductor cross-section for main contacts**|| |● solid or stranded|1 ... 10 mm²| |● finelystranded with core endprocessing|1 ... 6 mm²| |● finelystranded without core endprocessing|1 ... 6 mm²| |**connectable conductor cross-section for auxiliary contacts**|| |● solid or stranded|0.5 ... 2.5 mm²| |● finelystranded with core endprocessing|0.5 ... 1.5 mm²| |● finelystranded without core endprocessing|0.5 ... 1.5 mm²| |**type of connectable conductor cross-sections**|| |● for auxiliarycontacts|| |— solid or stranded|2x(0.5 ... 2.5 mm²)| |— finelystranded with core endprocessing|2x(0.5 ... 1.5 mm²)| |— finelystranded without core endprocessing|2x(0.5 ... 1.5 mm²)| |● for AWG cables for auxiliarycontacts|2x(20 ... 14)| |**AWG number as coded connectable conductor cross**<br>**section for main contacts**|18 ... 8| |**AWG number as coded connectable conductor cross**<br>**section for auxiliary contacts**|20 ... 14| |**design of screwdriver shaft**|Diameter 3 mm| |**size of the screwdriver tip**|3,0 x 0,5 mm| |**Safety related data**|| |product function suitable for safetyfunction|Yes| |**suitability for use**|| |● safety-related switchingon|No| |● safety-related switchingOFF|Yes| |**service life maximum**|10 a| |**test wear-related service life necessary**|Yes| |**proportion of dangerous failures**|| |● with low demand rate accordingto SN 31920|40 %| |● with high demand rate according to SN 31920|50 %| 3RV20211GA25 Page 4/6 Subject to change without notice © Copyright Siemens 5/30/2026 **==> picture [512 x 291] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |B10 value with high demand rate according to SN 31920|5 000| |failure rate [FIT] with low demand rate according to SN|50 FIT| |31920| |ISO 13849| |a| |device type according to ISO 13849-1|3| |overdimensioning according to ISO 13849-2 necessary|Yes| |IEC 61508| |a| |safety device type according to IEC 61508-2|Type A| |T1 value| |● for proof test interval or service life according to IEC|10 a| |61508| |a|Electrical Safety| |protection class IP on the front according to IEC 60529|IP20| |touch protection on the front according to IEC 60529|finger-safe, for vertical contact from the front| |re|Display| |display version for switching status|Handle| |Approvals Certificates| |Environmental Product Declaration| |a| |● global warming potential [CO2 eq] / during manufacturing|2.68 kg| |● global warming potential [CO2 eq] / during sales|0.143 kg| |● global warming potential [CO2 eq] / during operation|72.7 kg| |● global warming potential [CO2 eq] / after end of life|-0.445 kg| |● global warming potential [CO2 eq] / total|75.078 kg| |Environment|General Product Approval| **----- End of picture text -----**<br> Environmental Confirmations ~~—-—~~ **General Product Approval** **==> picture [479 x 244] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |For use in hazardous locations|Test Certificates|Maritime application| |-|-| |Special Test Certific|Type Test Certific| |ate|ates/Test Report| |ren|itas!| |Maritime application|other| |Confirmation|Miscellaneous|Confirmation| |other|Railway| |Miscellaneous|Confirmation|Special Test Certific-| |ate| |QC|PASS| |ee|i| **----- End of picture text -----**<br> **Further information** ~~ee~~ **Information on the packaging** 3RV20211GA25 Page 5/6 Subject to change without notice © Copyright Siemens 5/30/2026 https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2021-1GA25 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2021-1GA25 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2021-1GA25&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2021-1GA25 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **last modified:** 5/5/2026 3RV20211GA25 Page 6/6 Subject to change without notice © Copyright Siemens 5/30/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →