Image not available
Illustrative purposes only
3RV2021-0DA10
Thermal Magnetic Circuit Breaker, MPCB, 3RV2, 3P, 100 kA, 400 V, 0.32 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 71.17 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2021-0DA10** **Data sheet** Circuit breaker size S0 for motor protection, Class 10 A-release 0.22...0.32 A Short-circuit release 4.2 A Screw terminal Standard switching capacity |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S0| |**size of contactor can be combined company-specific**|S00, S0| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|5.5 W| |● at AC in hot operatingstateperpole|1.8 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP20| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|0.32 A| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|0.287 kg| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**|0.22 ... 0.32 A| |**dependent overload release**|| |**type of voltage for main current circuit**|AC| Subject to change without notice © Copyright Siemens 3RV20210DA10 Page 1/6 5/30/2026 ||**operating voltage**||| |---|---|---|---| ||● rated value|690 V|| ||● rated value|20 ... 690 V|| ||● at AC-3 rated value maximum|690 V|| ||● at AC-3e rated value maximum|690 V|| ||**operating frequency rated value**|50 ... 60 Hz|| ||**operational current rated value**|0.32 A|| ||**operational current**||| ||● at AC-3 at 400 V rated value|0.32 A|| ||● at AC-3e at 400 V rated value|0.32 A|| ||**operating power**||| ||● at AC-3||| ||— at 230 V rated value|0 kW|| ||— at 400 V rated value|0.1 kW|| ||— at 500 V rated value|0.1 kW|| ||— at 690 V rated value|0.1 kW|| ||● at AC-3e||| ||— at 230 V rated value|0 kW|| ||— at 400 V rated value|0.1 kW|| ||— at 500 V rated value|0.1 kW|| ||— at 690 V rated value|0.1 kW|| ||**operating frequency**||| ||● at AC-3 maximum|15 1/h|| ||● at AC-3e maximum|15 1/h|| ||**Auxiliary circuit**||| ||**type of voltage for auxiliary and control circuit**|AC/DC|| ||**number of NC contacts for auxiliary contacts**|0|| ||**number of NO contacts for auxiliary contacts**|0|| ||number of CO contacts for auxiliarycontacts|0|| ||**Protective and monitoring functions**||| ||**product function**||| ||●ground fault detection|No|| ||●phase failure detection|Yes|| ||**trip class**|CLASS 10|| ||**design of the overload release**|thermal|| ||**protection function thermal overloadprotection(ANSI 49)**|Yes|| ||**maximum short-circuit current breaking capacity (Icu)**||| ||● at AC at 240 V rated value|100 kA|| ||● at AC at 400 V rated value|100 kA|| ||● at AC at 500 V rated value|100 kA|| ||● at AC at 690 V rated value|100 kA|| ||**operating short-circuit current breaking capacity (Ics) at AC**||| ||● at 240 V rated value|100 kA|| ||● at 400 V rated value|100 kA|| ||● at 500 V rated value|100 kA|| ||● at 690 V rated value|100 kA|| ||response value current of instantaneous short-circuit trip unit|4.2 A|| ||**UL/CSA ratings**||| ||**full-load current(FLA) for 3-phase AC motor**||| ||● at 480 V rated value|0.32 A|| ||● at 600 V rated value|0.32 A|| ||**UL File Number(CCN)**|E47705(NLRV, NLRV7), E156943(NKJH, NKJH7)|| ||**Short-circuit protection**||| ||**product function short circuitprotection**|Yes|| ||**design of the short-circuit trip**|magnetic|| ||certificate of suitabilityaccordingto ATEX directive 2014/34/EU|DMT 02 ATEX F 001|| ||**type of protection according to ATEX directive 2014/34/EU**|Ex II(2)GD|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| Subject to change without notice © Copyright Siemens 3RV20210DA10 Page 2/6 5/30/2026 ||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|| |---|---|---|---| ||**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes|| ||**height**|97 mm|| ||**width**|45 mm|| ||**depth**|97 mm|| ||**required spacing**||| ||● with side-by-side mounting||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|0 mm|| ||● forgroundedparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— at the side|30 mm|| ||— downwards|50 mm|| ||● for liveparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|30 mm|| ||● forgroundedparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||● for liveparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||**Connections/ Terminals**||| ||**product component removable terminal for auxiliary and**<br>**control circuit**|No|| ||**type of electrical connection**||| ||● for main current circuit|screw-type terminals|| ||**arrangement of electrical connectors for main current**|Top and bottom|| Subject to change without notice © Copyright Siemens 3RV20210DA10 Page 3/6 5/30/2026 |**circuit**|| |---|---| |**type of connectable conductor cross-sections**|| |● for main contacts|| |— solid or stranded|2x(1 ... 2.5 mm²), 2x(2.5 ... 10 mm²)| |— finelystranded with core endprocessing|2x(1 ... 2.5 mm²), 2x(2.5 ... 6 mm²), 1x 10 mm²| |● for AWG cables for main contacts|2x(16 ... 12), 2x(14 ... 8)| |**connectable conductor cross-section for main contacts**|| |● solid or stranded|1 ... 10 mm²| |● finelystranded with core endprocessing|1 ... 10 mm²| |**AWG number as coded connectable conductor cross**<br>**section for main contacts**|18 ... 12| |**tightening torque**|| |● for main contacts with screw-type terminals|2 ... 2.5 N·m| |**design of screwdriver shaft**|Diameter 5 to 6 mm| |**size of the screwdriver tip**|Pozidriv size 2| |**design of the thread of the connection screw**|| |● for main contacts|M4| |**Safety related data**<br>~~|~~|| |product function suitable for safetyfunction<br>~~|~~|Yes<br>~~|~~| |**suitability for use**|| |● safety-related switchingon|No| |● safety-related switchingOFF|Yes| |**service life maximum**|10 a| |**test wear-related service life necessary**|Yes| |**proportion of dangerous failures**|| |● with low demand rate accordingto SN 31920|40 %| |● with high demand rate accordingto SN 31920|50 %| |**B10 value with high demand rate according to SN 31920**|5 000| |**failure rate [FIT] with low demand rate according to SN**<br>**31920**<br>~~OOOO~~|50 FIT<br>~~OOOO~~| |ISO 13849<br>~~OOOO~~|| |**device type according to ISO 13849-1**<br>~~OOOO~~<br>~~Se~~|3<br>~~OOOO~~<br>~~Se~~| |**overdimensioning according to ISO 13849-2 necessary**<br>~~Se~~|Yes<br>~~Se~~| |IEC 61508|| |**safety device type according to IEC 61508-2**|Type A| |**T1 value**|| |● for proof test interval or service life according to IEC<br>61508<br>~~OO~~|10 a<br>~~OO~~| |Electrical Safety<br>~~OO~~|| |**protection class IP on the front according to IEC 60529**<br>~~OO~~|IP20<br>~~OO~~| |**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front| |**Display**<br>~~|~~|| |displayversion for switchingstatus<br>~~|~~|Handle<br>~~|~~| |**Approvals Certificates**<br>~~ee~~|| |Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing<br>2.68 kg<br>● global warming potential [CO2 eq] / during sales<br>0.143 kg<br>● global warming potential [CO2 eq] / during operation<br>72.7 kg<br>● global warming potential [CO2 eq] / after end of life<br>-0.445 kg<br>● global warming potential [CO2 eq] / total<br>75.078 kg<br>**Environment**<br>**General Product Approval**<br>~~ee~~|| **General Product Approval** Subject to change without notice © Copyright Siemens 3RV20210DA10 Page 4/6 5/30/2026 |**For use in hazardous locations**|**For use in hazardous locations**||**Test Certificates**||**Maritime application**|| |---|---|---|---|---|---|---| |®||=|Special Test Certific-<br>ate<br>~~- ~~|Type Test Certific-<br>ates/Test Report<br> ~~—~~@||6| |**Maritime application**|||||**other**|| ||=||||Miscellaneous|Confirmation| |**other**|||**Railway**|||| |Miscellaneous<br>~~rn~~|QC|PASS|Confirmation|Special Test Certific-<br>ate||| ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2021-0DA10 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2021-0DA10 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2021-0DA10&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2021-0DA10 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> Subject to change without notice © Copyright Siemens 3RV20210DA10 Page 5/6 5/30/2026 **last modified:** 5/5/2026 Subject to change without notice © Copyright Siemens 3RV20210DA10 Page 6/6 5/30/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →