Image not available
Illustrative purposes only
3RV2011-1HA10-0BA0
Thermal Magnetic Circuit Breaker, MPCB, 3RV2, 3P, 100 kA, 400 V, 8 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 108.24 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2011-1HA10-0BA0** **Data sheet** Special type Circuit breaker size S00 for motor protection, CLASS 10 A-release 5.5...8 A N-release 104 A screw terminal Standard switching capacity Ambient temperature -50 °C 500 switching cycles |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S00| |**size of contactor can be combined company-specific**|S00, S0| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|9.25 W| |● at AC in hot operatingstateperpole|3.1 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP20| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|500| |● of auxiliarycontacts typical|500| |electrical endurance(operatingcycles)typical|500| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|8 A| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**Net Weight**|350g| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| Subject to change without notice © Copyright Siemens 3RV20111HA100BA0 Page 1/6 5/30/2026 |**ambient temperature**|| |---|---| |● duringoperation|-50 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**<br>**dependent overload release**|5.5 ... 8 A| |**type of voltage for main current circuit**|AC| |**operating voltage**|| |● rated value|690 V| |● rated value|20 ... 690 V| |● at AC-3 rated value maximum|690 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current rated value**|8 A| |**operational current**|| |● at AC-3 at 400 V rated value|8 A| |**operating power**|| |● at AC-3|| |— at 230 V rated value|1.5 kW| |— at 400 V rated value|3 kW| |— at 500 V rated value|4 kW| |— at 690 V rated value|5.5 kW| |**operating frequency**|| |● at AC-3 maximum|15 1/h| |**Auxiliary circuit**|| |**type of voltage for auxiliary and control circuit**|AC/DC| |**number of NC contacts for auxiliary contacts**|0| |**number of NO contacts for auxiliary contacts**|0| |number of CO contacts for auxiliarycontacts|0| |**Protective and monitoring functions**|| |**product function**|| |●ground fault detection|No| |●phase failure detection|Yes| |**trip class**|CLASS 10| |**design of the overload release**|thermal| |**protection function thermal overloadprotection(ANSI 49)**|Yes| |**maximum short-circuit current breaking capacity (Icu)**|| |● at AC at 240 V rated value|100 kA| |● at AC at 400 V rated value|100 kA| |● at AC at 500 V rated value|42 kA| |● at AC at 690 V rated value|6 kA| |**operating short-circuit current breaking capacity (Ics) at AC**|| |● at 240 V rated value|100 kA| |● at 400 V rated value|100 kA| |● at 500 V rated value|42 kA| |● at 690 V rated value|4 kA| |response value current of instantaneous short-circuit trip unit|104 A| |**Short-circuit protection**|| |**product function short circuitprotection**|Yes| |**design of the short-circuit trip**|magnetic| |**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**|| |● at 400 V|gG 50 A| |● at 500 V|gG 40 A| |● at 690 V|gG 35 A| |**Installation/ mounting/ dimensions**|| Subject to change without notice © Copyright Siemens 3RV20111HA100BA0 Page 2/6 5/30/2026 ||**mounting position**|any|| |---|---|---|---| ||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|| ||**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes|| ||**height**|97 mm|| ||**width**|45 mm|| ||**depth**|97 mm|| ||**required spacing**||| ||● with side-by-side mounting||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|0 mm|| ||● forgroundedparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— at the side|30 mm|| ||— downwards|50 mm|| ||● for liveparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|30 mm|| ||● forgroundedparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||● for liveparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||**Connections/ Terminals**||| ||**product component removable terminal for auxiliary and**<br>**control circuit**|No|| ||**type of electrical connection**||| ||● for main current circuit|screw-type terminals|| Subject to change without notice © Copyright Siemens 3RV20111HA100BA0 Page 3/6 5/30/2026 **==> picture [511 x 393] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |arrangement of electrical connectors for main current|Top and bottom| |circuit| |type of connectable conductor cross-sections| |● for main contacts| |— solid or stranded|2x (0,75 ... 2,5 mm²), 2x 4 mm²| |— finely stranded with core end processing|2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)| |connectable conductor cross-section for main contacts| |● solid or stranded|0.75 ... 4 mm²| |● finely stranded with core end processing|0.5 ... 2.5 mm²| |tightening torque| |● for main contacts with screw-type terminals|0.8 ... 1.2 N·m| |design of screwdriver shaft|Diameter 5 to 6 mm| |size of the screwdriver tip|Pozidriv size 2| |design of the thread of the connection screw| |● for main contacts|M3| |IEC 61508| |ee| |T1 value| |● for proof test interval or service life according to IEC|10 a| |61508| |ee|Electrical Safety| |protection class IP on the front according to IEC 60529|IP20| |touch protection on the front according to IEC 60529|finger-safe, for vertical contact from the front| |ee|Display| |display version for switching status|Handle| |Approvals Certificates| |l=|Environmental Product Declaration| |● global warming potential [CO2 eq] / during manufacturing|1.98 kg| |● global warming potential [CO2 eq] / during sales|0.134 kg| |● global warming potential [CO2 eq] / during operation|72.7 kg| |● global warming potential [CO2 eq] / after end of life|-0.116 kg| |● global warming potential [CO2 eq] / total|74.698 kg| |Environment|General Product Approval| **----- End of picture text -----**<br> **==> picture [489 x 271] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Environmental Con-| |firmations| |General Product Approval|Test Certificates| |-|-| |Special Test Certific|Type Test Certific| |ate|ates/Test Report| |Maritime application| |°|a|®| |EILAREES| |other|Railway| |Confirmation|Miscellaneous|Confirmation|Miscellaneous|Confirmation| **----- End of picture text -----**<br> **Railway** Subject to change without notice © Copyright Siemens 3RV20111HA100BA0 Page 4/6 5/30/2026 - Special Test Certific ate **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2011-1HA10-0BA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2011-1HA10-0BA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2011-1HA10-0BA0&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2011-1HA10-0BA0 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **==> picture [203 x 225] intentionally omitted <==** Subject to change without notice © Copyright Siemens 3RV20111HA100BA0 Page 5/6 5/30/2026 **==> picture [279 x 335] intentionally omitted <==** **----- Start of picture text -----**<br> -F<br>oo<br>oo<br>Po t e t o<br>I> I> I><br>|<br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3<br>2 4 6<br>**----- End of picture text -----**<br> **last modified:** 5/5/2026 Subject to change without notice © Copyright Siemens 3RV20111HA100BA0 Page 6/6 5/30/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →