3RV2011-1DA15
Thermal Magnetic Circuit Breaker, MPCB, 3RV2, 3P, 100 kA, 400 V, 3.2 A, Auxiliary Switch 1NO+1NC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 97.44 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2011-1DA15** **Data sheet** circuit breaker frame size S00 for motor protection, Class 10 thermal release 2.2...3.2 A short-circuit release 42 A screw terminal standard switching capacity with transverse auxiliary switch 1 NO+1 NC |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S00| |**size of contactor can be combined company-specific**|S00, S0| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|7.25 W| |● at AC in hot operatingstateperpole|2.4 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP20| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|3.2 A| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|362g| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**|2.2 ... 3.2 A| |**dependent overload release**|| |**type of voltage for main current circuit**|AC| Subject to change without notice © Copyright Siemens 3RV20111DA15 Page 1/6 5/30/2026 ||**operating voltage**||| |---|---|---|---| ||● rated value|690 V|| ||● rated value|20 ... 690 V|| ||● at AC-3 rated value maximum|690 V|| ||● at AC-3e rated value maximum|690 V|| ||**operating frequency rated value**|50 ... 60 Hz|| ||**operational current rated value**|3.2 A|| ||**operational current**||| ||● at AC-3 at 400 V rated value|3.2 A|| ||● at AC-3e at 400 V rated value|3.2 A|| ||**operating power**||| ||● at AC-3||| ||— at 230 V rated value|0.6 kW|| ||— at 400 V rated value|1.1 kW|| ||— at 500 V rated value|1.5 kW|| ||— at 690 V rated value|2.2 kW|| ||● at AC-3e||| ||— at 230 V rated value|0.6 kW|| ||— at 400 V rated value|1.1 kW|| ||— at 500 V rated value|1.5 kW|| ||— at 690 V rated value|2.2 kW|| ||**operating frequency**||| ||● at AC-3 maximum|15 1/h|| ||● at AC-3e maximum|15 1/h|| ||**Auxiliary circuit**||| ||**design of the auxiliary switch**|transverse|| ||**type of voltage for auxiliary and control circuit**|AC/DC|| ||**number of NC contacts for auxiliary contacts**|1|| ||**number of NO contacts for auxiliary contacts**|1|| ||number of CO contacts for auxiliarycontacts|0|| ||**operational current of auxiliary contacts at AC-15**||| ||● at 24 V|2 A|| ||● at 120 V|0.5 A|| ||● at 125 V|0.5 A|| ||● at 230 V|0.5 A|| ||**operational current of auxiliary contacts at DC-13**||| ||● at 24 V|1 A|| ||● at 60 V|0.15 A|| ||**Protective and monitoring functions**||| ||**product function**||| ||●ground fault detection|No|| ||●phase failure detection|Yes|| ||**trip class**|CLASS 10|| ||**design of the overload release**|thermal|| ||**protection function thermal overloadprotection(ANSI 49)**|Yes|| ||**maximum short-circuit current breaking capacity (Icu)**||| ||● at AC at 240 V rated value|100 kA|| ||● at AC at 400 V rated value|100 kA|| ||● at AC at 500 V rated value|100 kA|| ||● at AC at 690 V rated value|10 kA|| ||**operating short-circuit current breaking capacity (Ics) at AC**||| ||● at 240 V rated value|100 kA|| ||● at 400 V rated value|100 kA|| ||● at 500 V rated value|100 kA|| ||● at 690 V rated value|10 kA|| ||response value current of instantaneous short-circuit trip unit|42 A|| ||**UL/CSA ratings**||| ||**full-load current(FLA) for 3-phase AC motor**||| ||● at 480 V rated value|3.2 A|| Subject to change without notice © Copyright Siemens 3RV20111DA15 Page 2/6 5/30/2026 |● at 600 V rated value|3.2 A| |---|---| |**yielded mechanicalperformance[hp]**|| |● for single-phase AC motor|| |— at 110/120 V rated value|0.1 hp| |— at 230 V rated value|0.25 hp| |● for 3-phase AC motor|| |— at 200/208 V rated value|0.5 hp| |— at 220/230 V rated value|0.75 hp| |— at 460/480 V rated value|2 hp| |— at 575/600 V rated value|2 hp| |**contact rating of auxiliary contacts according to UL**|C300 / R300| |**UL File Number(CCN)**|E47705(NLRV, NLRV7), E156943(NKJH, NKJH7)| |**Short-circuit protection**|| |**product function short circuitprotection**|Yes| |**design of the short-circuit trip**|magnetic| |**design of the fuse link**|| |● for short-circuit protection of the auxiliary switch required|Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400<br>A)| |**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**|| |● at 400 V|gL/gG 25 A| |● at 500 V|gL/gG 32 A| |● at 690 V|gL/gG 25 A| |certificate of suitabilityaccordingto ATEX directive 2014/34/EU|DMT 02 ATEX F 001| |**type of protection according to ATEX directive 2014/34/EU**|Ex II(2)GD| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715| |**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes| |**height**|97 mm| |**width**|45 mm| |**depth**|97 mm| |**required spacing**|| |● with side-by-side mounting|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— downwards|50 mm| |— at the side|0 mm| |● forgroundedparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— at the side|30 mm| |— downwards|50 mm| |● for liveparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— downwards|50 mm| |— at the side|30 mm| |● forgroundedparts at 400 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● for liveparts at 400 V|| |— downwards|30 mm| |— upwards|30 mm| Subject to change without notice © Copyright Siemens 3RV20111DA15 Page 3/6 5/30/2026 |— at the side|9 mm| |---|---| |● forgroundedparts at 500 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● for liveparts at 500 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● forgroundedparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|30 mm| |— forwards|0 mm| |● for liveparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|30 mm| |— forwards|0 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|No| |**type of electrical connection**|| |● for main current circuit|screw-type terminals| |● for auxiliaryand control circuit|screw-type terminals| |**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom| |**type of connectable conductor cross-sections**|| |● for main contacts|| |— solid or stranded|2x(0,75 ... 2,5 mm²), 2x 4 mm²| |— finelystranded with core endprocessing|2x(0.5 ... 1.5 mm²), 2x(0.75 ... 2.5 mm²)| |● for AWG cables for main contacts|2x(18 ... 14), 2x 12| |**connectable conductor cross-section for main contacts**|| |● solid or stranded|0.75 ... 4 mm²| |● finelystranded with core endprocessing|0.5 ... 2.5 mm²| |**connectable conductor cross-section for auxiliary contacts**|| |● solid or stranded|0.5 ... 2.5 mm²| |● finelystranded with core endprocessing|0.5 ... 2.5 mm²| |**type of connectable conductor cross-sections**|| |● for auxiliarycontacts|| |— solid or stranded|2x(0.5 ... 1.5 mm²), 2x(0.75 ... 2.5 mm²)| |— finelystranded with core endprocessing|2x(0.5 ... 1.5 mm²), 2x(0.75 ... 2.5 mm²)| |● for AWG cables for auxiliarycontacts|2x(20 ... 16), 2x(18 ... 14)| |**AWG number as coded connectable conductor cross**<br>**section for main contacts**|18 ... 12| |**AWG number as coded connectable conductor cross**<br>**section for auxiliary contacts**|20 ... 14| |**tightening torque**|| |● for main contacts with screw-type terminals|0.8 ... 1.2 N·m| |● for auxiliarycontacts with screw-type terminals|0.8 ... 1.2 N·m| |**design of screwdriver shaft**|Diameter 5 to 6 mm| |**size of the screwdriver tip**|Pozidriv size 2| |**design of the thread of the connection screw**|| |● for main contacts|M3| |● of the auxiliaryand control contacts|M3| |**Safety related data**|| |product function suitable for safetyfunction|Yes| |**suitability for use**|| Subject to change without notice © Copyright Siemens 3RV20111DA15 Page 4/6 5/30/2026 |● safety-related switchingon|No||||||| |---|---|---|---|---|---|---|---| |● safety-related switchingOFF|Yes||||||| |**service life maximum**|10 a||||||| |**test wear-related service life necessary**|Yes||||||| |**proportion of dangerous failures**|||||||| |● with low demand rate accordingto SN 31920|40 %||||||| |● with high demand rate accordingto SN 31920|50 %||||||| |**B10 value with high demand rate according to SN 31920**|5 000||||||| |**failure rate [FIT] with low demand rate according to SN**|50 FIT||||||| |**31920**|||||||| |ISO 13849<br>**device type according to ISO 13849-1**<br>3<br>~~ee~~|||||||| |**overdimensioning according to ISO 13849-2 necessary**<br>Yes<br>IEC 61508<br>~~Ee~~|||||||| |**safety device type according to IEC 61508-2**|Type A|e A|||||| |**T1 value**|||||||| |● for proof test interval or service life according to IEC|10 a||||||| |61508|||||||| |Electrical Safety<br>**protection class IP on the front according to IEC 60529**<br>IP20<br>~~|~~|||||||| |**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front|||||er-safe, for vertical contact from the front|| |**Display**<br>~~ee~~|||||||| |displayversion for switchingstatus|Handle||||||| |**Approvals Certificates**<br>Environmental Product Declaration<br>~~————~~|||||||| |● global warming potential [CO2 eq] / during manufacturing|1.98 kg||||||| |● global warming potential [CO2 eq] / during sales|0.134 kg||||||| |● global warming potential [CO2 eq] / during operation|72.7 kg||||||| |● global warming potential [CO2 eq] / after end of life|-0.116 kg||||||| |● global warming potential [CO2 eq] / total|74.698 kg||74.698 kg||||| |**Environment**|||**General Product Approval**||||| |Environmental Con-<br>firmations<br>~~—————~~<br>@®|||||@||| |**General Product Approval**|||||||| |[¢<br>FAL ARY||||||ce|UK| |**For use in hazardous locations**<br>**Test Certificates**||||||**Maritime application**|| |Special Test Certific-<br>ate<br>Type Test Certific-<br>ates/Test Report<br>® ~~=~~~@|||||||PenTTA| |**Maritime application**<br>=<br>9|||||@|**other**<br>Miscellaneous<br> ~~— ~~|Confirmation<br> ~~—~~| |**other**<br>**Railway**|||||||| Subject to change without notice © Copyright Siemens 3RV20111DA15 Page 5/6 5/30/2026 Miscellaneous Confirmation Special Test Certific- ~~sd~~ Fant ~~rs~~ ate **Further information** ~~OO~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2011-1DA15 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2011-1DA15 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2011-1DA15&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2011-1DA15 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **last modified:** 5/5/2026 g Subject to change without notice © Copyright Siemens 3RV20111DA15 Page 6/6 5/30/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →