Image not available
Illustrative purposes only
3RV2011-1CA40
Thermal Magnetic Circuit Breaker, MPCB, 3RV2, 3P, 100 kA, 400 V, 2.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 73.07 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2011-1CA40** **Data sheet** Circuit breaker size S00 for motor protection, CLASS 10 A-release 1.8...2.5 A N- release 33 A ring cable lug connection Standard switching capacity |Siemens~~@~~<br>EcoTech|Circuit breaker size S00 for motor protection, CLASS 10 A-release 1.8...2.5 A N-<br>release 33 A ring cable lug connection Standard switching capacity| |---|---| |**product brand name**|SIRIUS| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection| |**product type designation**|3RV2| |**General technical data**<br>~~ee~~|| |**Product equipment of circuit breaker for motor protection**<br>**complete unit withprotection device**<br>~~ee~~|Yes<br>~~ee~~| |**size of the circuit-breaker**|S00| |**size of contactor can be combined company-specific**|S00, S0| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|7.25 W| |● at AC in hot operatingstateperpole|2.4 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and<br>auxiliarycircuit|400 V| |● in networks with grounded star point between main and<br>auxiliarycircuit|400 V| |**protection class IP**|| |● on the front accordingto IEC 60529|IP00| |● on the front|IP00| |● of the terminal|IP00| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|2.5 A| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**<br>~~EP~~|0.341 kg<br>| |**Ambient conditions**<br>~~EPti(‘(i*zr~~|| 3RV20111CA40 Page 1/7 Subject to change without notice © Copyright Siemens 6/3/2026 |installation altitude at height above sea level maximum|2 000 m| |---|---| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**<br>**dependent overload release**|1.8 ... 2.5 A| |**type of voltage for main current circuit**|AC| |**operating voltage**|| |● rated value|690 V| |● rated value|20 ... 690 V| |● at AC-3 rated value maximum|690 V| |● at AC-3e rated value maximum|690 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current rated value**|2.5 A| |**operational current**|| |● at AC-3 at 400 V rated value|2.5 A| |● at AC-3e at 400 V rated value|2.5 A| |**operating power**|| |● at AC-3|| |— at 230 V rated value|0.4 kW| |— at 400 V rated value|0.75 kW| |— at 500 V rated value|1.1 kW| |— at 690 V rated value|1.5 kW| |● at AC-3e|| |— at 230 V rated value|0.4 kW| |— at 400 V rated value|0.75 kW| |— at 500 V rated value|1.1 kW| |— at 690 V rated value|1.5 kW| |**operating frequency**|| |● at AC-3 maximum|15 1/h| |● at AC-3e maximum|15 1/h| |**Auxiliary circuit**|| |**type of voltage for auxiliary and control circuit**|AC/DC| |**number of NC contacts for auxiliary contacts**|0| |**number of NO contacts for auxiliary contacts**|0| |number of CO contacts for auxiliarycontacts|0| |**Protective and monitoring functions**|| |**product function**|| |●ground fault detection|No| |●phase failure detection|Yes| |**trip class**|CLASS 10| |**design of the overload release**|thermal| |**protection function thermal overloadprotection(ANSI 49)**|Yes| |**maximum short-circuit current breaking capacity (Icu)**|| |● at AC at 240 V rated value|100 kA| |● at AC at 400 V rated value|100 kA| |● at AC at 500 V rated value|100 kA| |● at AC at 690 V rated value|10 kA| |**operating short-circuit current breaking capacity (Ics) at AC**|| |● at 240 V rated value|100 kA| |● at 400 V rated value|100 kA| |● at 500 V rated value|100 kA| |● at 690 V rated value|10 kA| |response value current of instantaneous short-circuit trip unit|33 A| 3RV20111CA40 Page 2/7 Subject to change without notice © Copyright Siemens 6/3/2026 ||**UL/CSA ratings**|**UL/CSA ratings**|| |---|---|---|---| ||**full-load current(FLA) for 3-phase AC motor**||| ||● at 480 V rated value|2.5 A|| ||● at 600 V rated value|2.5 A|| ||**yielded mechanicalperformance[hp]**||| ||● for single-phase AC motor||| ||— at 230 V rated value|0.17 hp|| ||● for 3-phase AC motor||| ||— at 200/208 V rated value|0.5 hp|| ||— at 220/230 V rated value|0.5 hp|| ||— at 460/480 V rated value|1 hp|| ||— at 575/600 V rated value|1.5 hp|| ||**UL File Number(CCN)**|E47705(NLRV, NLRV7)|| ||**Short-circuit protection**||| ||**product function short circuitprotection**|Yes|| ||**design of the short-circuit trip**|magnetic|| ||**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**||| ||● at 400 V|gL/gG 25 A|| ||● at 500 V|gL/gG 25 A|| ||● at 690 V|gL/gG 20 A|| ||certificate of suitabilityaccordingto ATEX directive 2014/34/EU|DMT 02 ATEX F 001|| ||**type of protection according to ATEX directive 2014/34/EU**|Ex II(2)GD|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|| ||**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes|| ||**height**|97 mm|| ||**width**|45 mm|| ||**depth**|97 mm|| ||**required spacing**||| ||● with side-by-side mounting||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|0 mm|| ||● forgroundedparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— at the side|30 mm|| ||— downwards|50 mm|| ||● for liveparts||| ||— forwards|0 mm|| ||— backwards|0 mm|| ||— upwards|50 mm|| ||— downwards|50 mm|| ||— at the side|30 mm|| ||● forgroundedparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for grounded parts at 500 V||| 3RV20111CA40 Page 3/7 Subject to change without notice © Copyright Siemens 6/3/2026 |— downwards|30 mm| |---|---| |— upwards|30 mm| |— at the side|9 mm| |● for liveparts at 500 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● forgroundedparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|30 mm| |— forwards|0 mm| |● for liveparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|30 mm| |— forwards|0 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|No| |**type of electrical connection**|| |● for main current circuit|Ringcable lugconnection| |● for auxiliaryand control circuit|ringterminal lugconnection| |**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom| |**tightening torque**|| |● for main contacts for ringcable lug|0.8 ... 1.2 N·m| |● for auxiliarycontacts for ringcable lug|1.2 ... 0.8 N·m| |**outer diameter of the usable ring cable lug maximum**|7.5 mm| |**design of screwdriver shaft**|Diameter 5 to 6 mm| |**size of the screwdriver tip**|size 2 and Pozidriv 2| |**design of the thread of the connection screw**|| |● for main contacts|M3| |● of the auxiliaryand control contacts|M3| |**Safety related data**|| |product function suitable for safetyfunction|Yes| |**suitability for use**|| |● safety-related switchingon|No| |● safety-related switchingOFF|Yes| |**service life maximum**|10 a| |**test wear-related service life necessary**|Yes| |**proportion of dangerous failures**|| |● with low demand rate accordingto SN 31920|40 %| |● with high demand rate accordingto SN 31920|50 %| |**B10 value with high demand rate according to SN 31920**|5 000| |**failure rate [FIT] with low demand rate according to SN**<br>**31920**|50 FIT| |ISO 13849|| |**device type according to ISO 13849-1**|3| |**overdimensioning according to ISO 13849-2 necessary**|Yes| |IEC 61508|| |**safety device type according to IEC 61508-2**|Type A| |**T1 value**|| |● for proof test interval or service life according to IEC<br>61508|10 a| |Electrical Safety|| |**protection class IP on the front according to IEC 60529**|IP00| |**Display**|| 3RV20111CA40 Page 4/7 Subject to change without notice © Copyright Siemens 6/3/2026 **==> picture [510 x 724] intentionally omitted <==** **----- Start of picture text -----**<br> display version for switching status Handle<br>Approvals Certificates<br>—— Environmental Product Declaration ————<br>● global warming potential [CO2 eq] / during manufacturing 1.98 kg<br>● global warming potential [CO2 eq] / during sales 0.134 kg<br>● global warming potential [CO2 eq] / during operation 72.7 kg<br>● global warming potential [CO2 eq] / after end of life -0.116 kg<br>● global warming potential [CO2 eq] / total 74.698 kg<br>Environment General Product Approval<br>Environmental Con-<br>firmations<br>For use in hazard-<br>General Product Approval ous locations<br>For use in hazard-<br>ous locations Test Certificates Maritime application<br>- -<br>Special Test Certific Type Test Certific<br>ate ates/Test Report<br>eo ~——e @ g<br>Maritime application other<br>Miscellaneous Confirmation Miscellaneous<br>8<br>other Railway<br>Confirmation Special Test Certific-<br>ate<br>Pa es)<br>Further information<br>ee<br>Information on the packaging<br>https://support.industry.siemens.com/cs/ww/en/view/109813875<br>Information for data generation and storage<br>https://support.industry.siemens.com/cs/ww/en/view/109995012<br>Information- and Downloadcenter (Catalogs, Brochures,…)<br>https://www.siemens.com/ic10<br>Industry Mall (Online ordering system)<br>https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2011-1CA40<br>Service&Support (Manuals, Certificates, Characteristics, FAQs,...)<br>https://support.industry.siemens.com/cs/ww/en/ps/3RV2011-1CA40<br>Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)<br>https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2011-1CA40&lang=en<br>Cax online generator<br>https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2011-1CA40<br>Characteristic curves<br>https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no><br>**----- End of picture text -----**<br> 3RV20111CA40 Page 5/7 Subject to change without notice © Copyright Siemens 6/3/2026 **==> picture [511 x 718] intentionally omitted <==** 3RV20111CA40 Page 6/7 Subject to change without notice © Copyright Siemens 6/3/2026 **==> picture [343 x 368] intentionally omitted <==** **----- Start of picture text -----**<br> -F<br>||<br>ae<br>I> I> I><br>last modified: 5/5/2026 G<br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3<br>2 4 6<br>**----- End of picture text -----**<br> 3RV20111CA40 Page 7/7 Subject to change without notice © Copyright Siemens 6/3/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →