3RV2011-1BA25
Thermal Magnetic Circuit Breaker, MPCB, 3RV2, 3P, 100 kA, 400 V, 2 A, Auxiliary Switch 1NO+1NC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 97.44 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2011-1BA25** **Data sheet** circuit breaker frame size S00 for motor protection, Class 10 thermal release 1.4...2 A short-circuit release 26 A spring-loaded terminal standard switching capacity with transverse auxiliary switch 1 NO+1 NC |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S00| |**size of contactor can be combined company-specific**|S00, S0| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|7.25 W| |● at AC in hot operatingstateperpole|2.4 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP20| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|2 A| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|382g| |**Ambient conditions**|| Subject to change without notice © Copyright Siemens 3RV20111BA25 Page 1/7 5/29/2026 |installation altitude at height above sea level maximum|2 000 m| |---|---| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**<br>**dependent overload release**|1.4 ... 2 A| |**type of voltage for main current circuit**|AC| |**operating voltage**|| |● rated value|690 V| |● rated value|20 ... 690 V| |● at AC-3 rated value maximum|690 V| |● at AC-3e rated value maximum|690 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current rated value**|2 A| |**operational current**|| |● at AC-3 at 400 V rated value|2 A| |● at AC-3e at 400 V rated value|2 A| |**operating power**|| |● at AC-3|| |— at 230 V rated value|0.4 kW| |— at 400 V rated value|0.75 kW| |— at 500 V rated value|0.8 kW| |— at 690 V rated value|1.1 kW| |● at AC-3e|| |— at 230 V rated value|0.4 kW| |— at 400 V rated value|0.75 kW| |— at 500 V rated value|0.8 kW| |— at 690 V rated value|1.1 kW| |**operating frequency**|| |● at AC-3 maximum|15 1/h| |● at AC-3e maximum|15 1/h| |**Auxiliary circuit**|| |**design of the auxiliary switch**|transverse| |**type of voltage for auxiliary and control circuit**|AC/DC| |**number of NC contacts for auxiliary contacts**|1| |**number of NO contacts for auxiliary contacts**|1| |number of CO contacts for auxiliarycontacts|0| |**operational current of auxiliary contacts at AC-15**|| |● at 24 V|2 A| |● at 120 V|0.5 A| |● at 125 V|0.5 A| |● at 230 V|0.5 A| |**operational current of auxiliary contacts at DC-13**|| |● at 24 V|1 A| |● at 60 V|0.15 A| |**Protective and monitoring functions**|| |**product function**|| |●ground fault detection|No| |●phase failure detection|Yes| |**trip class**|CLASS 10| |**design of the overload release**|thermal| |**protection function thermal overloadprotection(ANSI 49)**|Yes| |**maximum short-circuit current breaking capacity (Icu)**|| |● at AC at 240 V rated value|100 kA| Subject to change without notice © Copyright Siemens 3RV20111BA25 Page 2/7 5/29/2026 |● at AC at 400 V rated value|100 kA| |---|---| |● at AC at 500 V rated value|100 kA| |● at AC at 690 V rated value|10 kA| |**operating short-circuit current breaking capacity (Ics) at AC**|| |● at 240 V rated value|100 kA| |● at 400 V rated value|100 kA| |● at 500 V rated value|100 kA| |● at 690 V rated value|10 kA| |response value current of instantaneous short-circuit trip unit|26 A| |**UL/CSA ratings**|| |**full-load current(FLA) for 3-phase AC motor**|| |● at 480 V rated value|2 A| |● at 600 V rated value|2 A| |**yielded mechanicalperformance[hp]**|| |● for single-phase AC motor|| |— at 230 V rated value|0.13 hp| |● for 3-phase AC motor|| |— at 460/480 V rated value|1 hp| |— at 575/600 V rated value|1 hp| |**contact rating of auxiliary contacts according to UL**|C300 / R300| |**UL File Number(CCN)**|E47705(NLRV, NLRV7), E156943(NKJH, NKJH7)| |**Short-circuit protection**|| |**product function short circuitprotection**|Yes| |**design of the short-circuit trip**|magnetic| |**design of the fuse link**|| |● for short-circuit protection of the auxiliary switch required|Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400<br>A)| |**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**|| |● at 400 V|gL/gG 25 A| |● at 500 V|gL/gG 25 A| |● at 690 V|gL/gG 20 A| |certificate of suitabilityaccordingto ATEX directive 2014/34/EU|DMT 02 ATEX F 001| |**type of protection according to ATEX directive 2014/34/EU**|Ex II(2)GD| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715| |**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes| |**height**|106 mm| |**width**|45 mm| |**depth**|97 mm| |**required spacing**|| |● with side-by-side mounting|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— downwards|50 mm| |— at the side|0 mm| |● forgroundedparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— at the side|30 mm| |— downwards|50 mm| |● for liveparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| Subject to change without notice © Copyright Siemens 3RV20111BA25 Page 3/7 5/29/2026 ||— downwards|50 mm|| |---|---|---|---| ||— at the side|30 mm|| ||● forgroundedparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 400 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● for liveparts at 500 V||| ||— downwards|30 mm|| ||— upwards|30 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||● for liveparts at 690 V||| ||— downwards|50 mm|| ||— upwards|50 mm|| ||— backwards|0 mm|| ||— at the side|30 mm|| ||— forwards|0 mm|| ||**Connections/ Terminals**||| ||**product component removable terminal for auxiliary and**<br>**control circuit**|No|| ||**type of electrical connection**||| ||● for main current circuit|spring-loaded terminals|| ||● for auxiliaryand control circuit|spring-loaded terminals|| ||**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom|| ||**type of connectable conductor cross-sections**||| ||● for main contacts||| ||— solid or stranded|2x(0,5 ... 4 mm²)|| ||— finelystranded with core endprocessing|2x(0.5 ... 2.5 mm²)|| ||— finelystranded without core endprocessing|2x(0.5 ... 2.5 mm²)|| ||● for AWG cables for main contacts|2x(20 ... 12)|| ||**connectable conductor cross-section for main contacts**||| ||● solid or stranded|0.5 ... 4 mm²|| ||● finelystranded with core endprocessing|0.5 ... 2.5 mm²|| ||● finelystranded without core endprocessing|0.5 ... 2.5 mm²|| ||**connectable conductor cross-section for auxiliary contacts**||| ||● solid or stranded|0.5 ... 2.5 mm²|| ||● finelystranded with core endprocessing|0.5 ... 1.5 mm²|| ||● finelystranded without core endprocessing|0.5 ... 1.5 mm²|| ||**type of connectable conductor cross-sections**||| ||● for auxiliarycontacts||| ||— solid or stranded|2x(0.5 ... 2.5 mm²)|| ||— finelystranded with core endprocessing|2x(0.5 ... 1.5 mm²)|| ||— finelystranded without core endprocessing|2x(0.5 ... 1.5 mm²)|| ||● for AWG cables for auxiliarycontacts|2x(20 ... 14)|| ||**AWG number as coded connectable conductor cross**<br>**section for main contacts**|20 ... 12|| Subject to change without notice © Copyright Siemens 3RV20111BA25 Page 4/7 5/29/2026 |**AWG number as coded connectable conductor cross**<br>**section for auxiliary contacts**<br>~~re~~|20 ... 14<br>~~re~~| |---|---| |**design of screwdriver shaft**<br>~~re~~|Diameter 3 mm<br>~~re~~| |**size of the screwdriver tip**<br>~~re~~|3,0 x 0,5 mm<br>~~re~~| |**Safety related data**|| |product function suitable for safetyfunction|Yes| |**suitability for use**|| |● safety-related switchingon|No| |● safety-related switchingOFF|Yes| |**service life maximum**|10 a| |**test wear-related service life necessary**|Yes| |**proportion of dangerous failures**|| |● with low demand rate accordingto SN 31920|40 %| |● with high demand rate accordingto SN 31920|50 %| |**B10 value with high demand rate according to SN 31920**|5 000| |**failure rate [FIT] with low demand rate according to SN**<br>**31920**<br>~~a~~|50 FIT<br>~~a~~| |ISO 13849<br>~~a~~|| |**device type according to ISO 13849-1**<br>~~a~~<br>~~by~~|3<br>~~a~~<br>~~by~~| |**overdimensioning according to ISO 13849-2 necessary**<br>~~by~~|Yes<br>~~by~~| |IEC 61508<br>~~by~~|| |**safety device type according to IEC 61508-2**<br>~~by~~|Type A<br>~~by~~| |**T1 value**|| |● for proof test interval or service life according to IEC<br>61508<br>~~Cnn~~|10 a<br>~~Cnn~~<br>~~SS~~<br>~~SSSSS)~~| |Electrical Safety<br>~~Cnn~~<br>~~SS~~<br>~~SSSSS)~~|| |**protection class IP on the front according to IEC 60529**<br>~~Cnn~~|IP20<br>~~Cnn~~<br>~~SS~~<br>~~SSSSS)~~| |**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front| |**Display**<br>~~a~~|| |displayversion for switchingstatus<br>~~a~~|Handle<br>~~a~~| |**Approvals Certificates**<br>~~——————EEE~~|| |Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing<br>1.98 kg<br>● global warming potential [CO2 eq] / during sales<br>0.134 kg<br>● global warming potential [CO2 eq] / during operation<br>72.7 kg<br>● global warming potential [CO2 eq] / after end of life<br>-0.116 kg<br>● global warming potential [CO2 eq] / total<br>74.698 kg<br>**Environment**<br>**General Product Approval**<br>~~——————EEE~~|| - global warming potential [CO2 eq] / during manufacturing 1.98 kg ● global warming potential [CO2 eq] / during sales 0.134 kg ● global warming potential [CO2 eq] / during operation 72.7 kg ● global warming potential [CO2 eq] / after end of life -0.116 kg ● global warming potential [CO2 eq] / total 74.698 kg - **Environment** **General Product Approval** Environmental Confirmations ## **General Product Approval** |**For use in hazardous locations**|**Test Certificates**||**Maritime application**| |---|---|---|---| ||Special Test Certific-|Type Test Certific-|| ||ate|ates/Test Report|| |**Maritime application**|||**other**| Subject to change without notice © Copyright Siemens 3RV20111BA25 Page 5/7 5/29/2026 Confirmation Miscellaneous **other Railway** Miscellaneous Confirmation Special Test Certificate ~~—_—~~ i aes ~~OO~~ ~~e~~ **Further information** ~~s~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2011-1BA25 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2011-1BA25 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2011-1BA25&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2011-1BA25 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> Subject to change without notice © Copyright Siemens 3RV20111BA25 Page 6/7 5/29/2026 **==> picture [384 x 260] intentionally omitted <==** **----- Start of picture text -----**<br> -F<br>|| _<br>L | | o f a f a<br>I> I> I><br>| [tt]<br>1/L1 3/L2 5/L3 13 21<br>/T1 /T2 /T3 14 22<br>2 4 6<br>**----- End of picture text -----**<br> **last modified:** 5/5/2026 Subject to change without notice © Copyright Siemens 3RV20111BA25 Page 7/7 5/29/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →