Image not available
Illustrative purposes only
3RV2011-0AA40
Thermal Magnetic Circuit Breaker, MPCB, 3RV2, 3P, 100 kA, 400 V, 0.16 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 63.28 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2011-0AA40**
**Data sheet**
Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.11...0.16 A N- release 2.1 A ring cable lug connection Standard switching capacity
|Siemens~~@~~<br>EcoTech|Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.11...0.16 A N-<br>release 2.1 A ring cable lug connection Standard switching capacity|
|---|---|
|**product brand name**|SIRIUS|
|**product designation**|Circuit breaker|
|**design of theproduct**|For motorprotection|
|**product type designation**|3RV2|
|**General technical data**<br>~~ee~~||
|**Product equipment of circuit breaker for motor protection**<br>**complete unit withprotection device**<br>~~ee~~|Yes<br>~~ee~~|
|**size of the circuit-breaker**|S00|
|**size of contactor can be combined company-specific**|S00, S0|
|product function disconnector functionality|Yes|
|product extension auxiliaryswitch|Yes|
|**power loss[W] for rated value of the current**||
|● at AC in hot operatingstate|5.5 W|
|● at AC in hot operatingstateperpole|1.8 W|
|**type of calculation ofpower loss current-dependent**|quadratic|
|insulation voltage with degree ofpollution 3 at AC rated value|690 V|
|**surge voltage resistance rated value**|6 kV|
|**maximumpermissible voltage forprotective separation**||
|● in networks with ungrounded star point between main and<br>auxiliarycircuit|400 V|
|● in networks with grounded star point between main and<br>auxiliarycircuit|400 V|
|**protection class IP**||
|● on the front accordingto IEC 60529|IP00|
|● on the front|IP00|
|● of the terminal|IP00|
|**shock resistance according to IEC 60068-2-27**|25g/ 11 ms|
|**mechanical service life(operating cycles)**||
|● of the main contacts typical|100 000|
|● of auxiliarycontacts typical|100 000|
|electrical endurance(operatingcycles)typical|100 000|
|**reference code according to IEC 81346-2**|Q|
|**continuous current rated value**|0.16 A|
|**Substance Prohibitance(day/month/year)**|10/01/2009|
|**SVHC substance name**|Lead CAS-No. 7439-92-1|
|**Net Weight**<br>~~EP~~|0.28 kg<br>|
|**Ambient conditions**<br>~~EPti(‘(i*zr~~||
Subject to change without notice © Copyright Siemens
3RV20110AA40 Page 1/7
6/2/2026
|installation altitude at height above sea level maximum|2 000 m|
|---|---|
|**ambient temperature**||
|● duringoperation|-20 ... +60 °C|
|● duringstorage|-50 ... +80 °C|
|● duringtransport|-50 ... +80 °C|
|**temperature compensation**|-20 ... +60 °C|
|relative humidityduringoperation|10 ... 95 %|
|**Main circuit**||
|**number ofpoles for main current circuit**|3|
|**adjustable current response value current of the current-**<br>**dependent overload release**|0.11 ... 0.16 A|
|**type of voltage for main current circuit**|AC|
|**operating voltage**||
|● rated value|690 V|
|● rated value|20 ... 690 V|
|● at AC-3 rated value maximum|690 V|
|● at AC-3e rated value maximum|690 V|
|**operating frequency rated value**|50 ... 60 Hz|
|**operational current rated value**|0.16 A|
|**operational current**||
|● at AC-3 at 400 V rated value|0.16 A|
|● at AC-3e at 400 V rated value|0.16 A|
|**operating power**||
|● at AC-3||
|— at 230 V rated value|0 kW|
|— at 400 V rated value|0.04 kW|
|— at 500 V rated value|0.1 kW|
|— at 690 V rated value|0.1 kW|
|● at AC-3e||
|— at 230 V rated value|0 kW|
|— at 400 V rated value|0.04 kW|
|— at 500 V rated value|0.1 kW|
|— at 690 V rated value|0.1 kW|
|**operating frequency**||
|● at AC-3 maximum|15 1/h|
|● at AC-3e maximum|15 1/h|
|**Auxiliary circuit**||
|**type of voltage for auxiliary and control circuit**|AC/DC|
|**number of NC contacts for auxiliary contacts**|0|
|**number of NO contacts for auxiliary contacts**|0|
|number of CO contacts for auxiliarycontacts|0|
|**Protective and monitoring functions**||
|**product function**||
|●ground fault detection|No|
|●phase failure detection|Yes|
|**trip class**|CLASS 10|
|**design of the overload release**|thermal|
|**protection function thermal overloadprotection(ANSI 49)**|Yes|
|**maximum short-circuit current breaking capacity (Icu)**||
|● at AC at 240 V rated value|100 kA|
|● at AC at 400 V rated value|100 kA|
|● at AC at 500 V rated value|100 kA|
|● at AC at 690 V rated value|100 kA|
|**operating short-circuit current breaking capacity (Ics) at AC**||
|● at 240 V rated value|100 kA|
|● at 400 V rated value|100 kA|
|● at 500 V rated value|100 kA|
|● at 690 V rated value|100 kA|
|response value current of instantaneous short-circuit trip unit|2.1 A|
Subject to change without notice © Copyright Siemens
3RV20110AA40 Page 2/7
6/2/2026
|**UL/CSA ratings**|**UL/CSA ratings**|
|---|---|
|**full-load current(FLA) for 3-phase AC motor**||
|● at 480 V rated value|0.16 A|
|● at 600 V rated value|0.16 A|
|**UL File Number(CCN)**|E47705(NLRV, NLRV7)|
|**Short-circuit protection**||
|**product function short circuitprotection**|Yes|
|**design of the short-circuit trip**|magnetic|
|certificate of suitabilityaccordingto ATEX directive 2014/34/EU|DMT 02 ATEX F 001|
|**type of protection according to ATEX directive 2014/34/EU**|Ex II(2)GD|
|**Installation/ mounting/ dimensions**||
|**mounting position**|any|
|**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|
|**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes|
|**height**|97 mm|
|**width**|45 mm|
|**depth**|97 mm|
|**required spacing**||
|● with side-by-side mounting||
|— forwards|0 mm|
|— backwards|0 mm|
|— upwards|50 mm|
|— downwards|50 mm|
|— at the side|0 mm|
|● forgroundedparts||
|— forwards|0 mm|
|— backwards|0 mm|
|— upwards|50 mm|
|— at the side|30 mm|
|— downwards|50 mm|
|● for liveparts||
|— forwards|0 mm|
|— backwards|0 mm|
|— upwards|50 mm|
|— downwards|50 mm|
|— at the side|30 mm|
|● forgroundedparts at 400 V||
|— downwards|30 mm|
|— upwards|30 mm|
|— at the side|9 mm|
|● for liveparts at 400 V||
|— downwards|30 mm|
|— upwards|30 mm|
|— at the side|9 mm|
|● forgroundedparts at 500 V||
|— downwards|30 mm|
|— upwards|30 mm|
|— at the side|9 mm|
|● for liveparts at 500 V||
|— downwards|30 mm|
|— upwards|30 mm|
|— at the side|9 mm|
|● forgroundedparts at 690 V||
|— downwards|50 mm|
|— upwards|50 mm|
|— backwards|0 mm|
|— at the side|30 mm|
Subject to change without notice © Copyright Siemens
3RV20110AA40 Page 3/7
6/2/2026
|— forwards|0 mm|0 mm|
|---|---|---|
|● for liveparts at 690 V|||
|— downwards|50 mm||
|— upwards|50 mm||
|— backwards|0 mm||
|— at the side|30 mm||
|— forwards|0 mm||
|**Connections/ Terminals**|||
|**product component removable terminal for auxiliary and**<br>**control circuit**|No||
|**type of electrical connection**|||
|● for main current circuit|Ringcable lugconnection||
|● for auxiliaryand control circuit|ringterminal lugconnection||
|**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom||
|**tightening torque**|||
|● for main contacts for ringcable lug|0.8 ... 1.2 N·m||
|● for auxiliarycontacts for ringcable lug|1.2 ... 0.8 N·m||
|**outer diameter of the usable ring cable lug maximum**|7.5 mm||
|**design of screwdriver shaft**|Diameter 5 to 6 mm||
|**size of the screwdriver tip**|size 2 and Pozidriv 2||
|**design of the thread of the connection screw**|||
|● for main contacts|M3||
|● of the auxiliaryand control contacts|M3||
|**Safety related data**|||
|product function suitable for safetyfunction|Yes||
|**suitability for use**|||
|● safety-related switchingon|No||
|● safety-related switchingOFF|Yes||
|**service life maximum**|10 a||
|**test wear-related service life necessary**|Yes||
|**proportion of dangerous failures**|||
|● with low demand rate accordingto SN 31920|40 %||
|● with high demand rate accordingto SN 31920|50 %||
|**B10 value with high demand rate according to SN 31920**|5 000||
|**failure rate [FIT] with low demand rate according to SN**<br>**31920**|50 FIT||
|ISO 13849|||
|**device type according to ISO 13849-1**|3||
|**overdimensioning according to ISO 13849-2 necessary**|Yes||
|IEC 61508|||
|**safety device type according to IEC 61508-2**|Type A||
|**T1 value**|||
|● for proof test interval or service life according to IEC<br>61508|10 a||
|Electrical Safety|||
|**protection class IP on the front according to IEC 60529**|IP00||
|**Display**|||
|displayversion for switchingstatus|Handle||
|**Approvals Certificates**|||
|Environmental Product Declaration|||
|● global warming potential [CO2 eq] / during manufacturing<br>1.98 kg<br>● global warming potential [CO2 eq] / during sales<br>0.134 kg<br>● global warming potential [CO2 eq] / during operation<br>72.7 kg<br>● global warming potential [CO2 eq] / after end of life<br>-0.116 kg<br>● global warming potential [CO2 eq] / total<br>74.698 kg<br>**Environment**<br>**General Product Approval**|1.98 kg||
||0.134 kg||
||72.7 kg||
||-0.116 kg||
||74.698 kg||
|||**General Product Approval**|
Subject to change without notice © Copyright Siemens
3RV20110AA40 Page 4/7
6/2/2026
Environmental Confirmations ~~—~~ & se” @ {[¢ **For use in hazardGeneral Product Approval ous locations** HE AR’ [8] ce BK **For use in hazardous locations Test Certificates Maritime application** - - Type Test Certific Special Test Certific ates/Test Report ate **Maritime application other** = ~~an~~ Miscellaneous Confirmation Miscellaneous **other Railway** Special Test CertificConfirmation ate Fagg) ~~——— — e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2011-0AA40 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2011-0AA40 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2011-0AA40&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2011-0AA40 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no>
Subject to change without notice © Copyright Siemens
3RV20110AA40 Page 5/7
6/2/2026
**==> picture [511 x 718] intentionally omitted <==**
Subject to change without notice © Copyright Siemens
3RV20110AA40 Page 6/7
6/2/2026
**==> picture [343 x 368] intentionally omitted <==**
**----- Start of picture text -----**<br>
-F<br>||<br>ae<br>I> I> I><br>last modified: 5/5/2026 G<br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3<br>2 4 6<br>**----- End of picture text -----**<br>
Subject to change without notice © Copyright Siemens
3RV20110AA40 Page 7/7
6/2/2026
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →