3RV1611-1CG14
Thermal Magnetic Circuit Breaker, Voltage XFMR, 3RV1, 3P, 50 kA, 400 V, 2.5A, Auxiliary Switch 1CO
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV1 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 358.44 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV1611-1CG14** **Data sheet** voltage transformer circuit breaker frame size S00 2.5 A, short-circuit release 10.5 A, 1 CO with transverse auxiliary switch ||voltage transformer circuit breaker frame size S00 2.5 A, short-circuit release 10.5<br>A, 1 CO with transverse auxiliary switch| |---|---| |**product brand name**|SIRIUS| |**product designation**|Circuit breaker| |**design of theproduct**|for distanceprotection| |**product type designation**|3RV1| |**General technical data**<br>~~a~~|| |**Product equipment of circuit breaker for motor protection**<br>**complete unit withprotection device**<br>~~a~~|Yes<br>~~a~~| |**size of the circuit-breaker**|S00| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|7.25 W| |● at AC in hot operatingstateperpole|2.4 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and<br>auxiliarycircuit|400 V| |● in networks with grounded star point between main and<br>auxiliarycircuit|400 V| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP00| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|10 000| |● of auxiliarycontacts typical|10 000| |electrical endurance(operatingcycles)typical|10 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|2.5 A| |**Substance Prohibitance(day/month/year)**|01/01/2013| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|300g| |**Ambient conditions**<br>~~a~~|| |installation altitude at height above sea level maximum<br>~~a~~|2 000 m<br>~~a~~| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● during transport|-50 ... +80 °C| 3RV16111CG14 Page 1/6 Subject to change without notice © Copyright Siemens 5/31/2026 |**temperature compensation**|-20 ... +60 °C| |---|---| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**type of voltage for main current circuit**|AC| |**operating voltage**|| |● rated value|400 V| |● rated value|20 ... 690 V| |● at AC-3 rated value maximum|400 V| |● at AC-3e rated value maximum|400 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current rated value**|2.5 A| |**operational current**|| |● at AC-3 at 400 V rated value|2.5 A| |● at AC-3e at 400 V rated value|2.5 A| |**operating frequency**|| |● at AC-3 maximum|15 1/h| |● at AC-3e maximum|15 1/h| |**Auxiliary circuit**|| |**design of the auxiliary switch**|transverse| |**type of voltage for auxiliary and control circuit**|AC/DC| |**number of NC contacts for auxiliary contacts**|1| |**number of NO contacts for auxiliary contacts**|1| |number of CO contacts for auxiliarycontacts|1| |**operational current of auxiliary contacts at DC-13**|| |● at 24 V|0.3 A| |● at 60 V|0.3 A| |**Protective and monitoring functions**|| |**product function**|| |●ground fault detection|No| |●phase failure detection|Yes| |**design of the overload release**|thermal| |**protection function thermal overloadprotection(ANSI 49)**|Yes| |**maximum short-circuit current breaking capacity (Icu)**|| |● at AC at 240 V rated value|100 kA| |● at AC at 400 V rated value|50 kA| |**operating short-circuit current breaking capacity (Ics) at AC**|| |● at 240 V rated value|100 kA| |● at 400 V rated value|50 kA| |response value current of instantaneous short-circuit trip unit|10.5 A| |**UL/CSA ratings**|| |**full-load current(FLA) for 3-phase AC motor**|| |● at 480 V rated value|2.5 A| |● at 600 V rated value|2.5 A| |**Short-circuit protection**|| |**product function short circuitprotection**|Yes| |**design of the short-circuit trip**|magnetic| |**design of the fuse link**|| |● for short-circuitprotection of the auxiliaryswitch required|2A FF 250V/1.1kA| |**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**|| |● at 240 V|none required| |● at 400 V|gG 35 A| |● at 500 V|gG 25 A| |● at 690 V|gG 25 A| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715| |**Mounting method of circuit breaker for Transformer**|Yes| 3RV16111CG14 Page 2/6 Subject to change without notice © Copyright Siemens 5/31/2026 |**protection, Generator protection and system protection**<br>**optional standard bar mounting**|| |---|---| |**height**|90 mm| |**width**|45 mm| |**depth**|75 mm| |**required spacing**|| |● forgroundedparts at 400 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● for liveparts at 400 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● forgroundedparts at 500 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● for liveparts at 500 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● forgroundedparts at 690 V|| |— downwards|20 mm| |— upwards|20 mm| |— backwards|0 mm| |— at the side|9 mm| |— forwards|0 mm| |● for liveparts at 690 V|| |— downwards|20 mm| |— upwards|20 mm| |— backwards|0 mm| |— at the side|9 mm| |— forwards|0 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|No| |**type of electrical connection**|| |● for main current circuit|screw-type terminals| |● for auxiliaryand control circuit|screw-type terminals| |**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom| |**type of connectable conductor cross-sections**|| |● for main contacts|| |— solid or stranded|2x(0,5 ... 1,5 mm²), 2x(0,75 ... 2,5 mm²), 2x(1 ... 4 mm²)| |— finelystranded with core endprocessing|2x(0.5 ... 1.5 mm²), 2x(0.75 ... 2.5 mm²)| |**connectable conductor cross-section for main contacts**|| |● solid or stranded|0.5 ... 4 mm²| |● finelystranded with core endprocessing|0.5 ... 2.5 mm²| |**connectable conductor cross-section for auxiliary contacts**|| |● solid or stranded|0.5 ... 2.5 mm²| |● finelystranded with core endprocessing|0.5 ... 2.5 mm²| |**type of connectable conductor cross-sections**|| |● for auxiliarycontacts|| |— solid or stranded|2x(0.5 ... 1.5 mm²), 2x(0.75 ... 2.5 mm²)| |**AWG number as coded connectable conductor cross**<br>**section for main contacts**|18 ... 14| |**AWG number as coded connectable conductor cross**<br>**section for auxiliary contacts**|18 ... 14| |**tightening torque**|| 3RV16111CG14 Page 3/6 Subject to change without notice © Copyright Siemens 5/31/2026 ● for main contacts with screw-type terminals 0.8 ... 1.2 N·m ● for auxiliary contacts with screw-type terminals 0.8 ... 1.2 N·m **design of screwdriver shaft** Diameter 5 to 6 mm **size of the screwdriver tip** Pozidriv size 2 **design of the thread of the connection screw** ● for main contacts M3 ● of the auxiliary and control contacts M3 Electrical Safety ~~a~~ **protection class IP on the front according to IEC 60529** IP20 **touch protection on the front according to IEC 60529** finger-safe, for vertical contact from the front ~~a~~ **Display** display version for switching status Rocker switch ~~a~~ **Approvals Certificates Environment General Product Approval** Environmental Confirmations ~~—~~ o (EFA **General Product Approval Test Certificates Maritime application** - - Type Test Certific Special Test Certific ates/Test Report ate ce eS - ©& 8B **Maritime application other** Miscellaneous Confirmation Miscellaneous = © — ~~— —~~~ Fae **Railway** - Special Test Certific ate ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV1611-1CG14 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV1611-1CG14 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV1611-1CG14&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV1611-1CG14 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> 3RV16111CG14 Page 4/6 Subject to change without notice © Copyright Siemens 5/31/2026 **==> picture [379 x 334] intentionally omitted <==** **----- Start of picture text -----**<br> -F<br>| | _<br>| [[|]<br>I> I> I><br>5/5/2026 G<br>13 21<br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3 14 22<br>2 4 6<br>**----- End of picture text -----**<br> **==> picture [49 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> last modified:<br>**----- End of picture text -----**<br> 3RV16111CG14 Page 5/6 Subject to change without notice © Copyright Siemens 5/31/2026 3RV16111CG14 Page 6/6 Subject to change without notice © Copyright Siemens 5/31/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →