3RV1611-0BD10
Thermal Magnetic Circuit Breaker, Fuse Monitoring, 3RV1, 3P, 100 kA, 400 V, 0.2 A,
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Available until stocks are exhausted
- No. of Poles: 3 Pole
- Product Range: SIRIUS 3RV1 Series
- Current Rating: 200mA
- Voltage Rating VAC: 690V
- Voltage Rating VDC: -
- Circuit Breaker Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 264.71 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV1611-0BD10** **Data sheet** Circuit breaker size S00 for fuse monitoring Screw terminal A-release 0.2 A N- release 1.2 A ||Circuit breaker size S00 for fuse monitoring Screw terminal A-release 0.2 A N-<br>release 1.2 A| |---|---| |**product brand name**|SIRIUS| |**product designation**|Circuit breaker| |**design of theproduct**|for fuse monitoring| |**product type designation**|3RV1| |**General technical data**<br>~~a~~|| |**Product equipment of circuit breaker for motor protection**<br>**complete unit withprotection device**<br>~~a~~|Yes<br>~~a~~| |**size of the circuit-breaker**|S00| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|5.5 W| |● at AC in hot operatingstateperpole|1.8 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and<br>auxiliarycircuit|400 V| |● in networks with grounded star point between main and<br>auxiliarycircuit|400 V| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP00| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|0.2 A| |**Substance Prohibitance(day/month/year)**|01/01/2013| |**Net Weight**|232g| |**Ambient conditions**<br>~~a~~|| |installation altitude at height above sea level maximum<br>~~a~~|2 000 m<br>~~a~~| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| Subject to change without notice © Copyright Siemens 3RV16110BD10 Page 1/6 5/30/2026 |relative humidityduringoperation|10 ... 95 %| |---|---| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**type of voltage for main current circuit**|AC/DC| |**operating voltage**|| |● rated value|690 V| |● rated value|20 ... 690 V| |● at AC-3 rated value maximum|690 V| |● at AC-3e rated value maximum|690 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current rated value**|0.2 A| |**operational current**|| |● at AC-3 at 400 V rated value|0.2 A| |● at AC-3e at 400 V rated value|0.2 A| |**operating frequency**|| |● at AC-3 maximum|15 1/h| |● at AC-3e maximum|15 1/h| |**Auxiliary circuit**|| |**type of voltage for auxiliary and control circuit**|AC/DC| |**number of NC contacts for auxiliary contacts**|0| |**number of NO contacts for auxiliary contacts**|0| |number of CO contacts for auxiliarycontacts|0| |**Protective and monitoring functions**|| |**product function**|| |●ground fault detection|No| |●phase failure detection|Yes| |**design of the overload release**|thermal| |**protection function thermal overloadprotection(ANSI 49)**|Yes| |**maximum short-circuit current breaking capacity (Icu)**|| |● at AC at 240 V rated value|100 kA| |● at AC at 400 V rated value|100 kA| |● at AC at 500 V rated value|100 kA| |● at AC at 690 V rated value|100 kA| |**operating short-circuit current breaking capacity (Ics) at AC**|| |● at 240 V rated value|100 kA| |● at 400 V rated value|100 kA| |● at 500 V rated value|100 kA| |● at 690 V rated value|100 kA| |**short-circuit current breaking capacity (Icn)**|| |● at 1 currentpath at DC at 150 V rated value|10 kA| |● with 2 currentpaths in series at DC at 300 V rated value|10 kA| |● with 3 currentpaths in series at DC at 450 V rated value|10 kA| |response value current of instantaneous short-circuit trip unit|1.2 A| |**UL/CSA ratings**|| |**full-load current(FLA) for 3-phase AC motor**|| |● at 480 V rated value|0.2 A| |● at 600 V rated value|0.2 A| |**Short-circuit protection**|| |**product function short circuitprotection**|Yes| |**design of the short-circuit trip**|magnetic| |**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**|| |● at 240 V|none required| |● at 400 V|None required| |● at 500 V|None required| |● at 690 V|None required| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715| Subject to change without notice © Copyright Siemens 3RV16110BD10 Page 2/6 5/30/2026 |**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes| |---|---| |**height**|90 mm| |**width**|45 mm| |**depth**|75 mm| |**required spacing**|| |● forgroundedparts at 400 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● for liveparts at 400 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● forgroundedparts at 500 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● for liveparts at 500 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● forgroundedparts at 690 V|| |— downwards|20 mm| |— upwards|20 mm| |— backwards|0 mm| |— at the side|9 mm| |— forwards|0 mm| |● for liveparts at 690 V|| |— downwards|20 mm| |— upwards|20 mm| |— backwards|0 mm| |— at the side|9 mm| |— forwards|0 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|No| |**type of electrical connection**|| |● for main current circuit|screw-type terminals| |**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom| |**type of connectable conductor cross-sections**|| |● for main contacts|| |— solid or stranded|2x(0,5 ... 1,5 mm²), 2x(0,75 ... 2,5 mm²), 2x(1 ... 4 mm²)| |— finelystranded with core endprocessing|2x(0.5 ... 1.5 mm²), 2x(0.75 ... 2.5 mm²)| |**connectable conductor cross-section for main contacts**|| |● solid or stranded|0.5 ... 4 mm²| |● finelystranded with core endprocessing|0.5 ... 2.5 mm²| |**type of connectable conductor cross-sections**|| |● for auxiliarycontacts|| |— solid or stranded|2x(0.5 ... 1.5 mm²), 2x(0.75 ... 2.5 mm²)| |**AWG number as coded connectable conductor cross**<br>**section for main contacts**|18 ... 14| |**tightening torque**|| |● for main contacts with screw-type terminals|0.8 ... 1.2 N·m| |● for auxiliarycontacts with screw-type terminals|0.8 ... 1.2 N·m| |**design of screwdriver shaft**|Diameter 5 to 6 mm| |**size of the screwdriver tip**|Pozidriv size 2| |**design of the thread of the connection screw**|| Subject to change without notice © Copyright Siemens 3RV16110BD10 Page 3/6 5/30/2026 |● for main contacts<br>M3||| |---|---|---| |Electrical Safety<br>**protection class IP on the front according to IEC 60529**<br>IP20<br>~~a~~||| |**touch protection on the front according to IEC 60529**<br>finger-safe, for vertical contact from the front||| |**Display**<br>~~a~~||| |displayversion for switchingstatus<br>Rocker switch||| |**Approvals Certificates**<br>~~ee~~||| |**Environment**<br>**General Product Approval**||| |Environmental Con-<br>firmations<br>~~—~~<br>[e<br>EAL||c¢| |**General Product Ap-**<br>**proval**<br>**Test Certificates**<br>**Maritime application**||| |Type Test Certific-<br>ates/Test Report<br>Special Test Certific-<br>ate<br>UuK<br>~~a—~~<br>~~——~~<br>CA<br>©|ti<br>=|cs<br>&| |**Maritime application**<br>**other**||**Railway**| |Miscellaneous<br>Confirmation<br>Miscellaneous<br>~~re~~||Special Test Certific-<br>ate| |**Further information**<br>~~ee~~||| |**Information on the packaging**||| |https://support.industry.siemens.com/cs/ww/en/view/109813875||| |**Information for data generation and storage**||| |https://support.industry.siemens.com/cs/ww/en/view/109995012||| |**Information- and Downloadcenter (Catalogs, Brochures,…)**||| |https://www.siemens.com/ic10||| |**Industry Mall (Online ordering system)**||| |https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV1611-0BD10||| |**Service&Support (Manuals, Certificates, Characteristics, FAQs,...)**||| |https://support.industry.siemens.com/cs/ww/en/ps/3RV1611-0BD10||| |**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**||| |https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV1611-0BD10&lang=en||| |**Cax online generator**||| |https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV1611-0BD10||| |**Characteristic curves**||| |https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no>||| Subject to change without notice © Copyright Siemens 3RV16110BD10 Page 4/6 5/30/2026 **==> picture [49 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> last modified:<br>**----- End of picture text -----**<br> **==> picture [263 x 365] intentionally omitted <==** **----- Start of picture text -----**<br> -F<br>I> I> I><br>5/5/2026 a<br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3<br>2 4 6<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3RV16110BD10 Page 5/6 5/30/2026 Subject to change without notice © Copyright Siemens 3RV16110BD10 Page 6/6 5/30/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →