Image not available
Illustrative purposes only
3RV1011-1KA10
Thermal Magnetic Circuit Breaker, MPCB, 3RV1, 3P, 50 kA, 400 V, 12.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV1 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 94.83 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV1011-1KA10** **Data sheet** Circuit breaker size S00 for motor protection, CLASS 10 A-release 9...12 A N- release 156 A Screw terminal Standard switching capacity ||Circuit breaker size S00 for motor protection, CLASS 10 A-release 9...12 A N-<br>release 156 A Screw terminal Standard switching capacity| |---|---| |**product brand name**|SIRIUS| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection| |**product type designation**|3RV1| |**General technical data**<br>~~ee~~|| |**Product equipment of circuit breaker for motor protection**<br>**complete unit withprotection device**<br>~~ee~~|Yes<br>~~ee~~| |**size of the circuit-breaker**|S00| |**size of contactor can be combined company-specific**|S00| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|9.25 W| |● at AC in hot operatingstateperpole|3.1 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and<br>auxiliarycircuit|400 V| |● in networks with grounded star point between main and<br>auxiliarycircuit|400 V| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP00| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|12 A| |**Substance Prohibitance(day/month/year)**|01/01/2013| |**Net Weight**|270g| |**Ambient conditions**<br>~~ee~~|| |installation altitude at height above sea level maximum<br>~~ee~~|2 000 m<br>~~ee~~| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● during transport|-50 ... +80 °C| Subject to change without notice © Copyright Siemens 3RV10111KA10 Page 1/6 5/29/2026 |**temperature compensation**|-20 ... +60 °C| |---|---| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**<br>**dependent overload release**|9 ... 12 A| |**type of voltage for main current circuit**|AC| |**operating voltage**|| |● rated value|690 V| |● rated value|20 ... 690 V| |● at AC-3 rated value maximum|690 V| |● at AC-3e rated value maximum|690 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current rated value**|12 A| |**operational current**|| |● at AC-3 at 400 V rated value|12 A| |● at AC-3e at 400 V rated value|12 A| |**operating power**|| |● at AC-3|| |— at 230 V rated value|3 kW| |— at 400 V rated value|5.5 kW| |— at 500 V rated value|5.5 kW| |— at 690 V rated value|7.5 kW| |● at AC-3e|| |— at 230 V rated value|3 kW| |— at 400 V rated value|5.5 kW| |— at 500 V rated value|5.5 kW| |— at 690 V rated value|7.5 kW| |**operating frequency**|| |● at AC-3 maximum|15 1/h| |● at AC-3e maximum|15 1/h| |**Auxiliary circuit**|| |**type of voltage for auxiliary and control circuit**|AC/DC| |**number of NC contacts for auxiliary contacts**|0| |**number of NO contacts for auxiliary contacts**|0| |number of CO contacts for auxiliarycontacts|0| |**Protective and monitoring functions**|| |**product function**|| |●ground fault detection|No| |●phase failure detection|Yes| |**trip class**|CLASS 10| |**design of the overload release**|thermal| |**protection function thermal overloadprotection(ANSI 49)**|Yes| |**maximum short-circuit current breaking capacity (Icu)**|| |● at AC at 240 V rated value|100 kA| |● at AC at 400 V rated value|50 kA| |● at AC at 500 V rated value|3 kA| |● at AC at 690 V rated value|2 kA| |**operating short-circuit current breaking capacity (Ics) at AC**|| |● at 240 V rated value|100 kA| |● at 400 V rated value|12.5 kA| |● at 500 V rated value|3 kA| |● at 690 V rated value|2 kA| |response value current of instantaneous short-circuit trip unit|156 A| |**UL/CSA ratings**|| |**full-load current(FLA) for 3-phase AC motor**|| |● at 480 V rated value|12 A| |● at 600 V rated value|12 A| |**yielded mechanical performance [hp]**|| Subject to change without notice © Copyright Siemens 3RV10111KA10 Page 2/6 5/29/2026 |● for single-phase AC motor|| |---|---| |— at 110/120 V rated value|0.5 hp| |— at 230 V rated value|2 hp| |● for 3-phase AC motor|| |— at 200/208 V rated value|3 hp| |— at 220/230 V rated value|3 hp| |— at 460/480 V rated value|8 hp| |— at 575/600 V rated value|10 hp| |**Short-circuit protection**|| |**product function short circuitprotection**|Yes| |**design of the short-circuit trip**|magnetic| |**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**|| |● at 240 V|gG 80 A| |● at 400 V|gG 80 A| |● at 500 V|gG 50 A| |● at 690 V|gG 50 A| |certificate of suitabilityaccordingto ATEX directive 2014/34/EU|DMT 02 ATEX F 001| |**type of protection according to ATEX directive 2014/34/EU**|Ex II(2)GD| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715| |**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes| |**height**|90 mm| |**width**|45 mm| |**depth**|75 mm| |**required spacing**|| |● forgroundedparts at 400 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● for liveparts at 400 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● forgroundedparts at 500 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● for liveparts at 500 V|| |— downwards|20 mm| |— upwards|20 mm| |— at the side|9 mm| |● forgroundedparts at 690 V|| |— downwards|20 mm| |— upwards|20 mm| |— backwards|0 mm| |— at the side|9 mm| |— forwards|0 mm| |● for liveparts at 690 V|| |— downwards|20 mm| |— upwards|20 mm| |— backwards|0 mm| |— at the side|9 mm| |— forwards|0 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|No| Subject to change without notice © Copyright Siemens 3RV10111KA10 Page 3/6 5/29/2026 |**type of electrical connection**|**type of electrical connection**|| |---|---|---| |● for main current circuit||screw-type terminals| |**arrangement of electrical connectors for main current**<br>**circuit**||Top and bottom| |**type of connectable conductor cross-sections**||| |● for main contacts||| |— solid or stranded||2x(0,5 ... 1,5 mm²), 2x(0,75 ... 2,5 mm²), 2x(1 ... 4 mm²)| |— finelystranded with core endprocessing||2x(0.5 ... 1.5 mm²), 2x(0.75 ... 2.5 mm²)| |**connectable conductor cross-section for main contacts**||| |● solid or stranded||0.5 ... 4 mm²| |● finelystranded with core endprocessing||0.5 ... 2.5 mm²| |**type of connectable conductor cross-sections**||| |● for auxiliarycontacts||| |— solid or stranded||2x(0.5 ... 1.5 mm²), 2x(0.75 ... 2.5 mm²)| |**AWG number as coded connectable conductor cross**<br>**section for main contacts**||18 ... 14| |**tightening torque**||| |● for main contacts with screw-type terminals||0.8 ... 1.2 N·m| |● for auxiliarycontacts with screw-type terminals||0.8 ... 1.2 N·m| |**design of screwdriver shaft**||Diameter 5 to 6 mm| |**size of the screwdriver tip**||Pozidriv size 2| |**design of the thread of the connection screw**||| |● for main contacts||M3| |**Safety related data**<br>~~rr~~||| |product function suitable for safetyfunction<br>~~rr~~||Yes<br>~~rr~~| |**suitability for use**||| |● safety-related switchingon||No| |● safety-related switchingOFF||Yes| |**service life maximum**||10 a| |**test wear-related service life necessary**||Yes| |**proportion of dangerous failures**||| |● with low demand rate accordingto SN 31920||40 %| |● with high demand rate accordingto SN 31920||50 %| |**B10 value with high demand rate according to SN 31920**||5 000| |**failure rate [FIT] with low demand rate according to SN**<br>**31920**<br>~~P|~~||50 FIT<br>~~P|~~| |ISO 13849<br>~~P|~~||| |**device type according to ISO 13849-1**<br>~~P|~~||3<br>~~P|~~| |**overdimensioning according to ISO 13849-2 necessary**<br>~~ee~~||Yes<br>~~ee~~| |IEC 61508<br>~~ee~~||| |**safety device type according to IEC 61508-2**<br>~~ee~~<br>~~ee~~||Type A<br>~~ee~~<br>~~ee~~| |Electrical Safety<br>~~ee~~||| |**protection class IP on the front according to IEC 60529**<br>~~ee~~||IP20<br>~~ee~~| |**touch protection on the front according to IEC 60529**||finger-safe, for vertical contact from the front| |**Display**<br>~~a~~||| |displayversion for switchingstatus<br>~~a~~||Rocker switch<br>~~a~~| |**Approvals Certificates**<br>~~a~~||| |**Environment**<br>~~a~~|**General Product Approval**<br>~~a~~|| **General Product Approval** **For use in hazardous locations** **Test Certificates** - - Type Test Certific Special Test Certific ates/Test Report ate ~~—~~ Subject to change without notice © Copyright Siemens 3RV10111KA10 Page 4/6 5/29/2026 **Maritime application other** Miscellaneous = = fo ca inna! ABS —— Ga FaNA MRS **other Railway** Confirmation Miscellaneous Special Test Certificate ~~—_—— —_—~~ rPnas| ~~[ _—] —~~ QC PASS ~~a~~ **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV1011-1KA10 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV1011-1KA10 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV1011-1KA10&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV1011-1KA10 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> Subject to change without notice © Copyright Siemens 3RV10111KA10 Page 5/6 5/29/2026 **==> picture [343 x 368] intentionally omitted <==** **----- Start of picture text -----**<br> -F<br>|||<br>|||<br>I> I> I><br>last modified: 5/5/2026 g<br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3<br>2 4 6<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3RV10111KA10 Page 6/6 5/29/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →