3RV1011-0AA15
Thermal Magnetic Circuit Breaker, MPCB, 3RV1, 3P, 100 kA, 400 V, 0.16 A, Auxiliary Switch 1NO+1NC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV1 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 90.48 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV1011-0AA15** **Data sheet** Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.11...0.16 A N- release 2.1 A Screw terminal Standard switching capacity with transverse auxiliary switch 1 NO+1 NC ||Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.11...0.16 A N-<br>release 2.1 A Screw terminal Standard switching capacity with transverse auxiliary<br>switch 1 NO+1 NC| |---|---| |**product brand name**|SIRIUS| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection| |**product type designation**|3RV1| |**General technical data**<br>~~Se~~|| |**Product equipment of circuit breaker for motor protection**<br>**complete unit withprotection device**<br>~~Se~~|Yes<br>~~Se~~| |**size of the circuit-breaker**|S00| |**size of contactor can be combined company-specific**|S00| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|5.5 W| |● at AC in hot operatingstateperpole|1.8 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and<br>auxiliarycircuit|400 V| |● in networks with grounded star point between main and<br>auxiliarycircuit|400 V| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP00| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|0.16 A| |**Substance Prohibitance(day/month/year)**|01/01/2013| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|240g| |**Ambient conditions**<br>~~Se~~|| |installation altitude at height above sea level maximum<br>~~Se~~|2 000 m<br>~~Se~~| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● during storage|-50 ... +80 °C| Subject to change without notice © Copyright Siemens 3RV10110AA15 Page 1/7 5/31/2026 |● duringtransport|-50 ... +80 °C| |---|---| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**<br>**dependent overload release**|0.11 ... 0.16 A| |**type of voltage for main current circuit**|AC| |**operating voltage**|| |● rated value|690 V| |● rated value|20 ... 690 V| |● at AC-3 rated value maximum|690 V| |● at AC-3e rated value maximum|690 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current rated value**|0.16 A| |**operational current**|| |● at AC-3 at 400 V rated value|0.16 A| |● at AC-3e at 400 V rated value|0.16 A| |**operating power**|| |● at AC-3|| |— at 230 V rated value|0 kW| |— at 400 V rated value|0.04 kW| |— at 500 V rated value|0.06 kW| |— at 690 V rated value|0.06 kW| |● at AC-3e|| |— at 230 V rated value|0 kW| |— at 400 V rated value|0.04 kW| |— at 500 V rated value|0.06 kW| |— at 690 V rated value|0.06 kW| |**operating frequency**|| |● at AC-3 maximum|15 1/h| |● at AC-3e maximum|15 1/h| |**Auxiliary circuit**|| |**design of the auxiliary switch**|transverse| |**type of voltage for auxiliary and control circuit**|AC/DC| |**number of NC contacts for auxiliary contacts**|1| |**number of NO contacts for auxiliary contacts**|1| |number of CO contacts for auxiliarycontacts|0| |**operational current of auxiliary contacts at AC-15**|| |● at 24 V|2 A| |● at 110 V|2 A| |● at 120 V|2 A| |● at 125 V|2 A| |● at 230 V|0.5 A| |**operational current of auxiliary contacts at DC-13**|| |● at 24 V|1 A| |● at 60 V|0.15 A| |**Protective and monitoring functions**|| |**product function**|| |●ground fault detection|No| |●phase failure detection|Yes| |**trip class**|CLASS 10| |**design of the overload release**|thermal| |**protection function thermal overloadprotection(ANSI 49)**|Yes| |**maximum short-circuit current breaking capacity (Icu)**|| |● at AC at 240 V rated value|100 kA| |● at AC at 400 V rated value|100 kA| |● at AC at 500 V rated value|100 kA| |● at AC at 690 V rated value|100 kA| Subject to change without notice © Copyright Siemens 3RV10110AA15 Page 2/7 5/31/2026 ||**operating short-circuit current breaking capacity (Ics) at AC**||| |---|---|---|---| ||● at 240 V rated value|100 kA|| ||● at 400 V rated value|100 kA|| ||● at 500 V rated value|100 kA|| ||● at 690 V rated value|100 kA|| ||response value current of instantaneous short-circuit trip unit|2.1 A|| ||**UL/CSA ratings**||| ||**full-load current(FLA) for 3-phase AC motor**||| ||● at 480 V rated value|0.16 A|| ||● at 600 V rated value|0.16 A|| ||**contact rating of auxiliary contacts according to UL**|C300 / R300|| ||**Short-circuit protection**||| ||**product function short circuitprotection**|Yes|| ||**design of the short-circuit trip**|magnetic|| ||**design of the fuse link**||| ||● for short-circuitprotection of the auxiliaryswitch required|fusegG: 10 A, miniature circuit breaker C 6 A(short-circuit current Ik < 400 A)|| ||**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**||| ||● at 240 V|none required|| ||● at 400 V|None required|| ||● at 500 V|None required|| ||● at 690 V|None required|| ||certificate of suitabilityaccordingto ATEX directive 2014/34/EU|DMT 02 ATEX F 001|| ||**type of protection according to ATEX directive 2014/34/EU**|Ex II(2)GD|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715|| ||**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes|| ||**height**|90 mm|| ||**width**|45 mm|| ||**depth**|75 mm|| ||**required spacing**||| ||● forgroundedparts at 400 V||| ||— downwards|20 mm|| ||— upwards|20 mm|| ||— at the side|9 mm|| ||● for liveparts at 400 V||| ||— downwards|20 mm|| ||— upwards|20 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 500 V||| ||— downwards|20 mm|| ||— upwards|20 mm|| ||— at the side|9 mm|| ||● for liveparts at 500 V||| ||— downwards|20 mm|| ||— upwards|20 mm|| ||— at the side|9 mm|| ||● forgroundedparts at 690 V||| ||— downwards|20 mm|| ||— upwards|20 mm|| ||— backwards|0 mm|| ||— at the side|9 mm|| ||— forwards|0 mm|| ||● for liveparts at 690 V||| ||— downwards|20 mm|| ||— upwards|20 mm|| ||— backwards|0 mm|| Subject to change without notice © Copyright Siemens 3RV10110AA15 Page 3/7 5/31/2026 |— at the side|— at the side|9 mm| |---|---|---| |— forwards||0 mm| |**Connections/ Terminals**||| |**product component removable terminal for auxiliary and**<br>**control circuit**||No| |**type of electrical connection**||| |● for main current circuit||screw-type terminals| |● for auxiliaryand control circuit||screw-type terminals| |**arrangement of electrical connectors for main current**<br>**circuit**||Top and bottom| |**type of connectable conductor cross-sections**||| |● for main contacts||| |— solid or stranded||2x(0,5 ... 1,5 mm²), 2x(0,75 ... 2,5 mm²), 2x(1 ... 4 mm²)| |— finelystranded with core endprocessing||2x(0.5 ... 1.5 mm²), 2x(0.75 ... 2.5 mm²)| |**connectable conductor cross-section for main contacts**||| |● solid or stranded||0.5 ... 4 mm²| |● finelystranded with core endprocessing||0.5 ... 2.5 mm²| |**connectable conductor cross-section for auxiliary contacts**||| |● solid or stranded||0.5 ... 2.5 mm²| |● finelystranded with core endprocessing||0.5 ... 2.5 mm²| |**type of connectable conductor cross-sections**||| |● for auxiliarycontacts||| |— solid or stranded||2x(0.5 ... 1.5 mm²), 2x(0.75 ... 2.5 mm²)| |**AWG number as coded connectable conductor cross**<br>**section for main contacts**||18 ... 14| |**AWG number as coded connectable conductor cross**<br>**section for auxiliary contacts**||18 ... 14| |**tightening torque**||| |● for main contacts with screw-type terminals||0.8 ... 1.2 N·m| |● for auxiliarycontacts with screw-type terminals||0.8 ... 1.2 N·m| |**design of screwdriver shaft**||Diameter 5 to 6 mm| |**size of the screwdriver tip**||Pozidriv size 2| |**design of the thread of the connection screw**||| |● for main contacts||M3| |● of the auxiliaryand control contacts||M3| |**Safety related data**||| |product function suitable for safetyfunction||Yes| |**suitability for use**||| |● safety-related switchingon||No| |● safety-related switchingOFF||Yes| |**service life maximum**||10 a| |**test wear-related service life necessary**||Yes| |**proportion of dangerous failures**||| |● with low demand rate accordingto SN 31920||40 %| |● with high demand rate accordingto SN 31920||50 %| |**B10 value with high demand rate according to SN 31920**||5 000| |**failure rate [FIT] with low demand rate according to SN**<br>**31920**||50 FIT| |ISO 13849||| |**device type according to ISO 13849-1**||3| |**overdimensioning according to ISO 13849-2 necessary**||Yes| |IEC 61508||| |**safety device type according to IEC 61508-2**||Type A| |Electrical Safety||| |**protection class IP on the front according to IEC 60529**||IP20| |**touch protection on the front according to IEC 60529**||finger-safe, for vertical contact from the front| |**Display**||| |displayversion for switchingstatus||Rocker switch| |**Approvals Certificates**||| |**Environment**|**General Product Approval**|| Subject to change without notice © Copyright Siemens 3RV10110AA15 Page 4/7 5/31/2026 **==> picture [489 x 316] intentionally omitted <==** **----- Start of picture text -----**<br> Environmental Con-<br>firmations<br>—<br>© » kK mH<br>General Product Approval For use in hazardous locations Test Certificates<br>- -<br>Special Test Certific Type Test Certific<br>ate ates/Test Report<br>Maritime application other<br>e 2° ® — Confirmation<br>other Railway<br>Miscellaneous Confirmation Miscellaneous Special Test Certific-<br>ate<br>PASS<br>es QC e e<br>**----- End of picture text -----**<br> ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV1011-0AA15 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV1011-0AA15 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV1011-0AA15&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV1011-0AA15 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> Subject to change without notice © Copyright Siemens 3RV10110AA15 Page 5/7 5/31/2026 **==> picture [381 x 260] intentionally omitted <==** **----- Start of picture text -----**<br> -F<br>[|| _<br>Tapas<br>I> I> I><br>13 21<br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3 14 22<br>2 4 6<br>**----- End of picture text -----**<br> **last modified:** 5/5/2026 Subject to change without notice © Copyright Siemens 3RV10110AA15 Page 6/7 5/31/2026 Subject to change without notice © Copyright Siemens 3RV10110AA15 Page 7/7 5/31/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →