Image not available
Illustrative purposes only
3RQ2000-2CW00
Optocoupler, 3CO, 240 VAC/VDC, Relays
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Other Relay Accessories
- Product Range: SIRIUS 3RQ2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 76.12 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RQ2000-2CW00** **Data sheet** Coupling relay in industrial enclosure 3 changeover contacts Wide voltage range 24 V to 240 V AC/DC Spring-type terminals ||Coupling relay in industrial enclosure 3 changeover contacts Wide voltage range<br>24 V to 240 V AC/DC Spring-type terminals| |---|---| |**product brand name**|SIRIUS| |**product designation**|Couplingrelayin industrial enclosure| |**product type designation**|3RQ2| |**General technical data**|| |**product featureprotective coating onprinted-circuit board**|No| |**consumed activepower**|2.5 W| |insulation voltage for overvoltage category III according to IEC<br>60664 with degree ofpollution 3 rated value|300 V| |**degree ofpollution**|3| |**surge voltage resistance rated value**|4 kV| |**maximumpermissible voltage forprotective separation**|| |● between auxiliaryand auxiliarycircuit|300 V| |● between control and auxiliary circuit according to IEC<br>60947-1|300 V| |**shock resistance**|| |**● according to IEC 60068-2-27**|11g/ 15 ms| |● for railwayapplications accordingto EN 61373|Category1, Class B| |**vibration resistance**|| |**● according to IEC 60068-2-6**|10 ... 55 Hz: 0.35 mm| |● for railwayapplications accordingto EN 61373|Category1, Class B| |**switching behavior**|monostable| |**mechanical service life(operating cycles) typical**|10 000 000| |electrical endurance(operatingcycles)at AC-15 at 230 V typical|100 000| |**thermal current of the switching element with contacts**<br>**maximum**|5 A| |**reference code according to IEC 81346-2**|K| |**Substance Prohibitance(day/month/year)**|05/31/2018| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1| |**Net Weight**|0.169 kg| |**Control circuit/ Control**|| |**control supply voltage at AC**|| |● at 50 Hz rated value|24 ... 240 V| |● at 50 Hz|24 ... 240 V| |● at 60 Hz rated value|24 ... 240 V| |● at 60 Hz|24 ... 240 V| |**control supply voltage at DC rated value**|24 ... 240 V| 3RQ20002CW00 Page 1/5 Subject to change without notice © Copyright Siemens 5/29/2026 ||**control supply voltage at DC**|24 ... 240 V|| |---|---|---|---| ||**operating range factor control supply voltage rated value at**<br>**DC**||| ||● initial value|0.7|| ||● full-scale value|1.1|| ||**operating range factor control supply voltage rated value at**<br>**AC at 50 Hz**||| ||● initial value|0.7|| ||● full-scale value|1.1|| ||**operating range factor control supply voltage rated value at**<br>**AC at 60 Hz**||| ||● initial value|0.7|| ||● full-scale value|1.1|| ||**ON-delay time**||| ||● at AC maximum|10 ms|| ||● at DC maximum|10 ms|| ||**OFF-delay time maximum**|100 ms|| ||**Switching Function**||| ||**design of the switching function**|CO contact|| ||**Mechanical data**||| ||**product componentplug-in socket**|No|| ||**design of the relay operating mechanism**|poled|| ||**Short-circuit protection**||| ||design of the fuse link for short-circuit protection of the auxiliary<br>switch required|fuse gL/gG: 6 A|| ||**Auxiliary circuit**||| ||**material of switching contacts**|AgSnO2|| ||**number of NC contacts for auxiliary contacts**|0|| ||**number of NO contacts for auxiliary contacts**|0|| ||number of CO contacts for auxiliarycontacts|3|| ||**contact reliability of auxiliary contacts**|one incorrect switching operation of 100 million switching operations (17 V, 5<br>mA)|| ||**type of voltage**|AC/DC|| ||**ampacity of the output relay at AC-15**||| ||● at 24 V at 50/60 Hz|3 A|| ||● at 110 V at 50/60 Hz|3 A|| ||● at 250 V at 50/60 Hz|3 A|| ||**ampacity of the output relay at DC-13**||| ||● at 24 V|1 A|| ||● at 125 V|0.2 A|| ||● at 250 V|0.1 A|| ||**Electromagnetic compatibility**||| ||EMC emitted interference accordingto IEC 60947-1|ambience A(industrial sector)|| ||EMC immunityaccordingto IEC 60947-1|corresponds to degree of severity3|| ||**conducted interference**||| ||● due to burst accordingto IEC 61000-4-4|2 kV|| ||● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV(line toground)|| ||● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV (line to line)|| ||**field-based interference according to IEC 61000-4-3**|10 V/m|| ||**electrostatic discharge according to IEC 61000-4-2**|4 kV contact discharging, 8 kV air discharging|| ||**Display**||| ||**product component LED**|Yes|| ||**Connections/ Terminals**||| ||**product component removable terminal for auxiliary and**<br>**control circuit**|Yes|| ||**type of electrical connection**|spring-loaded terminal(push-in)|| ||**type of connectable conductor cross-sections**||| ||● solid|1x(0.5 ... 4 mm²)|| ||● finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²)|| ||● for AWG cables solid|1x(20 ... 12)|| 3RQ20002CW00 Page 2/5 Subject to change without notice © Copyright Siemens 5/29/2026 |**connectable conductor cross-section**|||| |---|---|---|---| |● solid||0.5 ... 4 mm²|| |● finelystranded with core endprocessingmaximum||2.5 mm²|| |● finelystranded without core endprocessingminimum||0.5 mm²|| |**AWG number as coded connectable conductor cross**|||| |**section**|||| |● solid||12 ... 20|| |● stranded||12 ... 20|| |stripped length of the cable for auxiliaryand control contacts||10 mm|| |**Installation/ mounting/ dimensions**<br>~~a~~|||| |**mounting position**||any|| |**fastening method**||screw and sna|screw and snap-on mountingonto 35 mm DIN rail| |**height**||100 mm|| |**width**||22.5 mm|| |**depth**||90 mm|| |**Ambient conditions**<br>~~a~~|||| |installation altitude at height above sea level maximum||2 000 m|| |**ambient temperature**|||| |● duringoperation||-40 ... +60 °C|-40 ... +60 °C| |● duringstorage||-40 ... +80 °C|-40 ... +80 °C| |● duringtransport||-40 ... +80 °C|-40 ... +80 °C| |relative humidityduringoperation||10 ... 95 %|| |**Approvals Certificates**<br>~~Oe~~|||| |**Environment**<br>**General Product Approval**|||| |Environmental Con-|||| |firmations|||| ||||| |**EMV**<br>**Test Certificates**||**Maritime application**|| |Type Test Certific-|||| |ates/Test Report|||| |**Maritime application**<br>**other**||**Railway**|| |Confirmation<br>—_<br>Beare|||Confirmation<br>oe| |**Further information**<br>~~aS~~|||| |**Information on the packaging**|||| |https://support.industry.siemens.com/cs/ww/en/view/109813875|||| |**Information for data generation and storage**|||| |https://support.industry.siemens.com/cs/ww/en/view/109995012|||| |**Information- and Downloadcenter (Catalogs, Brochures,…)**|||| |https://www.siemens.com/ic10|||| |**Industry Mall (Online ordering system)**|||| |https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RQ2000-2CW00|||| |**Cax online generator**|||| |https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RQ2000-2CW00|||| |**Service&Support (Manuals, Certificates, Characteristics, FAQs,...)**|||| |https://support.industry.siemens.com/cs/ww/en/ps/3RQ2000-2CW00|||| |**Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)**|||| |https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RQ2000-2CW00&lang=en|||| 3RQ20002CW00 Page 3/5 Subject to change without notice © Copyright Siemens 5/29/2026 **==> picture [377 x 324] intentionally omitted <==** **----- Start of picture text -----**<br> -K<br>A1 (+) 11 21 31<br>A2 (-) 12 14 22 24 32 34<br>**----- End of picture text -----**<br> **last modified:** 5/16/2026 3RQ20002CW00 Page 4/5 Subject to change without notice © Copyright Siemens 5/29/2026 3RQ20002CW00 Page 5/5 Subject to change without notice © Copyright Siemens 5/29/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →