Time Delay Relay, 240 VDC, 0.05 s, 240 s, 3RP Series, SPST-NO, DIN Rail
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Time Delay Relays - Electromechanical
- Product Range: SIRIUS 3RP25 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 67.51 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RP2527-1EW30** **Data sheet** Timing relay, electronic slow-operating 1 NO (semiconductor) 2-wire 4 time ranges 0.05...240 s 12-240 V AC/DC screw terminal |Timing relay, electronic slow-operating 1 NO (semiconductor) 2-wire 4 time ranges<br>0.05...240 s 12-240 V AC/DC screw terminal<br>**product brand name**<br>SIRIUS<br>**product designation**<br>timingrelay<br>**design of theproduct**<br>slow-operating<br>**product type designation**<br>3RP25<br>**General technical data**<br>**product featureprotective coating onprinted-circuit board**<br>No<br>**product component**<br>● relayoutput<br>No<br>● semi-conductor output<br>Yes<br>**product extension required remote control**<br>No<br>**product extension optional remote control**<br>No<br>**power loss[W] maximum**<br>2 W<br>**test voltage for isolation test**<br>2.5 kV<br>**degree ofpollution**<br>3<br>**surge voltage resistance rated value**<br>4 000 V<br>**shock resistance according to IEC 60068-2-27**<br>11g/ 15 ms<br>**vibration resistance according to IEC 60068-2-6**<br>10 ... 55 Hz / 0.35 mm<br>**mechanical service life(operating cycles) typical**<br>10 000 000<br>electrical endurance(operatingcycles)at AC-15 at 230 V typical<br>100 000<br>**adjustable time**<br>0.05 ... 240 s<br>**relative setting accuracy relating to full-scale value**<br>5 %; +/-<br>**thermal current**<br>0.6 A<br>**recovery time**<br>250 ms<br>**reference code according to IEC 81346-2**<br>K<br>**relative repeat accuracy**<br>1 %; +/-<br>**influence of the surrounding temperature**<br>1% in the whole temperature range to the set runtime<br>**power supply influence**<br>1% in the whole voltage range to the set runtime<br>**Substance Prohibitance(day/month/year)**<br>09/12/2014<br>**SVHC substance name**<br>Lead CAS-No. 7439-92-1<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>**Net Weight**<br>0.119 kg<br>**Control circuit/ Control**<br>**type of voltage of the control supply voltage**<br>AC/DC<br>**control supply voltage at AC**<br>● at 50 Hz rated value<br>12 ... 240 V<br>● at 60 Hz rated value<br>12 ... 240 V<br>**control supply voltage 1 at AC**<br>● at 50 Hz<br>12 ... 240 V<br>● at 60 Hz<br>12 ... 240 V<br>Sony|Timing relay, electronic slow-operating 1 NO (semiconductor) 2-wire 4 time ranges<br>0.05...240 s 12-240 V AC/DC screw terminal|| |---|---|---| ||SIRIUS|| ||timingrelay|| ||slow-operating|| ||3RP25|| ||AC/DC|| |||| ||12 ... 240 V|| ||12 ... 240 V|| |||| ||12 ... 240 V|| ||12 ... 240 V|| Subject to change without notice © Copyright Siemens 3RP25271EW30 Page 1/6 6/2/2026 |**control supply voltage frequency 1**|50 ... 60 Hz| |---|---| |**control supply voltage at DC rated value**|12 ... 240 V| |**control supply voltage 1 at DC**|12 ... 240 V| |**operating range factor control supply voltage rated value at**<br>**DC**|| |● initial value|0.8| |● full-scale value|1.1| |**operating range factor control supply voltage rated value at**<br>**AC at 50 Hz**|| |● initial value|0.8| |● full-scale value|1.1| |**operating range factor control supply voltage rated value at**<br>**AC at 60 Hz**|| |● initial value|0.8| |● full-scale value|1.1| |**inrush currentpeak**|| |● at 24 V|0.1 A| |● at 240 V|1 A| |**duration of inrush currentpeak**|| |● at 24 V|0.01 ms| |● at 240 V|0.04 ms| |**Switching Function**|| |**switching function**|| |● ON-delay|Yes| |● ON-delay/instantaneous contact|No| |●passingmake contact|No| |●passingmake contact/instantaneous contact|No| |● OFF delay|No| |**switching function**|| |● flashingsymmetricallywith interval start/instantaneous|No| |● flashingsymmetricallywith interval start|No| |● flashingsymmetricallywithpulse start/instantaneous|No| |● flashingsymmetricallywithpulse start|No| |● flashingasymmetricallywith interval start|No| |● flashingasymmetricallywithpulse start|No| |**switching function**|| |● star-delta circuit with delaytime|No| |● star-delta circuit|No| |**switching function with control signal**|| |● additive ON-delay|No| |●passingbreak contact|No| |●passingbreak contact/instantaneous|No| |● OFF delay|No| |● OFF delay/instantaneous|No| |●pulse delayed|No| |●pulse delayed/instantaneous|No| |●pulse-shaping|No| |●pulse-shaping/instantaneous|No| |● additive ON-delay/instantaneous|No| |● ON-delay/OFF-delay/instantaneous|No| |●passingmake contact|No| |●passingmake contact/instantaneous contact|No| |**switching function of interval relay with control signal**|| |● retrotriggerable with deactivated control<br>signal/instantaneous contact|No| |● retrotriggerable with switched-on control signal|No| |● retrotriggerable with switched-on control<br>signal/instantaneous contact|No| |● retriggerable with deactivated control signal|No| |**Short-circuit protection**|| Subject to change without notice © Copyright Siemens 3RP25271EW30 Page 2/6 6/2/2026 ||design of the fuse link for short-circuit protection of the auxiliary<br>switch required|fuse gL/gG: 4 A|| |---|---|---|---| ||**Auxiliary circuit**||| ||**number of NC contacts**||| ||● delayed switching|0|| ||● instantaneous contact|0|| ||**number of NO contacts**||| ||● delayed switching|1|| ||● instantaneous contact|0|| ||**number of CO contacts**||| ||● delayed switching|0|| ||● instantaneous contact|0|| ||**operating frequency with 3RT2 contactor maximum**|5 000 1/h|| ||**switching capacity current with inductive load**|0.01 ... 0.6 A|| ||**Inputs/ Outputs**||| ||**product function**||| ||● at the relayoutputs switchover delayed/without delay|No|| ||● non-volatile|No|| ||residual current maximum|5 mA|| ||**Electromagnetic compatibility**||| ||EMC emitted interference accordingto IEC 61812-1|ambience A(industrial sector)|| ||EMC immunityaccordingto IEC 61812-1|corresponds to degree of severity3|| ||**conducted interference**||| ||● due to burst accordingto IEC 61000-4-4|2 kV network connection / 1 kV control connection|| ||● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV|| ||● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV|| ||**field-based interference according to IEC 61000-4-3**|10 V/m|| ||**electrostatic discharge according to IEC 61000-4-2**|4 kV contact discharge / 8 kV air discharge|| ||**Safety related data**||| ||categoryaccordingto EN 954-1|none|| ||Electrical Safety||| ||**protection class IP on the front according to IEC 60529**|IP20|| ||**Connections/ Terminals**||| ||**product component removable terminal for auxiliary and**<br>**control circuit**|Yes|| ||**type of electrical connection**|screw terminal|| ||● for auxiliaryand control circuit|screw-type terminals|| ||**type of connectable conductor cross-sections**||| ||● solid|1x(0.5 ... 4 mm²), 2x(0.5 ... 2.5 mm²)|| ||● finelystranded with core endprocessing|1x(0.5 ... 4 mm²), 2x(0.5 ... 1.5 mm²)|| ||● for AWG cables solid|1x(20 ... 12), 2x(20 ... 14)|| ||**connectable conductor cross-section**||| ||● solid|0.5 ... 4 mm²|| ||● finelystranded with core endprocessing|0.5 ... 4 mm²|| ||**AWG number as coded connectable conductor cross**<br>**section**||| ||● solid|20 ... 12|| ||**tightening torque**|0.6 ... 0.8 N·m|| ||**design of the thread of the connection screw**|M3|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail|| ||**height**|100 mm|| ||**width**|17.5 mm|| ||**depth**|90 mm|| ||**required spacing**||| ||● with side-by-side mounting||| ||— forwards|0 mm|| ||— backwards|0 mm|| Subject to change without notice © Copyright Siemens 3RP25271EW30 Page 3/6 6/2/2026 — upwards 0 mm — downwards 0 mm — at the side 0 mm ● for grounded parts — forwards 0 mm — backwards 0 mm — upwards 0 mm — at the side 0 mm — downwards 0 mm ● for live parts — forwards 0 mm — backwards 0 mm — upwards 0 mm — downwards 0 mm — at the side 0 mm ~~ee~~ **Ambient conditions** installation altitude at height above sea level maximum 2 000 m **ambient temperature** ● during operation -25 ... +60 °C ● during storage -40 ... +85 °C ● during transport -40 ... +85 °C relative humidity during operation 10 ... 95 % ~~ee~~ **Approvals Certificates Environment General Product Approval EMV** Environmental Confirmations **EMV Test Certificates Maritime application** - Type Test Certific ates/Test Report a ~~o~~ © i **Maritime application other** ~~—~~ Confirmation ~~—~~ Confirmation ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RP2527-1EW30 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RP2527-1EW30 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RP2527-1EW30 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RP2527-1EW30&lang=en Subject to change without notice © Copyright Siemens 3RP25271EW30 Page 4/6 6/2/2026 **==> picture [153 x 336] intentionally omitted <==** **----- Start of picture text -----**<br> -K<br>A1<br>A2<br>**----- End of picture text -----**<br> **==> picture [34 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 5/29/2026<br>**----- End of picture text -----**<br> **last modified:** Subject to change without notice © Copyright Siemens 3RP25271EW30 Page 5/6 6/2/2026 Subject to change without notice © Copyright Siemens 3RP25271EW30 Page 6/6 6/2/2026
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →