Image not available
Illustrative purposes only
3RP2525-1BB30
Time Delay Relay, 24 VDC, 0.05 s, 100 h, 3RP Series, 2CO, DIN Rail
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Time Delay Relays - Electromechanical
- Product Range: SIRIUS 3RP25 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 95.7 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RP2525-1BB30** **Data sheet** Timing relay, electronic on-delay 2 change-over contacts, 7 time ranges 0.05 s...100 h 24 V AC/DC at 50/60 Hz AC with LED, screw terminal |SIEMENS<br>Res|Timing relay, electronic on-delay 2 change-over contacts, 7 time ranges 0.05<br>s...100 h 24 V AC/DC at 50/60 Hz AC with LED, screw terminal| |---|---| |**product brand name**|SIRIUS| |**product designation**|timingrelay| |**design of theproduct**|slow-operating| |**product type designation**|3RP25| |**General technical data**|| |**product featureprotective coating onprinted-circuit board**|No| |**product component**|| |● relayoutput|Yes| |● semi-conductor output|No| |**product extension required remote control**|No| |**product extension optional remote control**|No| |**power loss[W] maximum**|2 W| |insulation voltage for overvoltage category III according to IEC<br>60664 with degree ofpollution 3 rated value|300 V| |**test voltage for isolation test**|2.5 kV| |**degree ofpollution**|3| |**surge voltage resistance rated value**|4 000 V| |**shock resistance according to IEC 60068-2-27**|11g/ 15 ms| |**vibration resistance according to IEC 60068-2-6**|10 ... 55 Hz / 0.35 mm| |**mechanical service life(operating cycles) typical**|10 000 000| |electrical endurance(operatingcycles)at AC-15 at 230 V typical|100 000| |**adjustable time**|0.05 s ... 100 h| |**relative setting accuracy relating to full-scale value**|5 %; +/-| |**thermal current**|5 A| |**recovery time**|150 ms| |**reference code according to IEC 81346-2**|K| |**relative repeat accuracy**|1 %; +/-| |**influence of the surrounding temperature**|1% in the whole temperature range to the set runtime| |**power supply influence**|1% in the whole voltage range to the set runtime| |**Substance Prohibitance(day/month/year)**|09/12/2014| |**Net Weight**|0.162 kg| |**Control circuit/ Control**|| |**type of voltage of the control supply voltage**|AC/DC| |**control supply voltage at AC**|| |● at 50 Hz rated value|24 V| |● at 60 Hz rated value|24 V| |**control supply voltage 1 at AC**|| |● at 50 Hz rated value|24 V| |● at 60 Hz rated value|24 V| Subject to change without notice © Copyright Siemens 3RP25251BB30 Page 1/6 6/3/2026 |**control supply voltage frequency 1**|50 ... 60 Hz| |---|---| |**control supply voltage at DC rated value**|24 V| |**control supply voltage 1 at DC rated value**|24 V| |**operating range factor control supply voltage rated value at**<br>**DC**|| |● initial value|0.85| |● full-scale value|1.1| |**operating range factor control supply voltage rated value at**<br>**AC at 50 Hz**|| |● initial value|0.85| |● full-scale value|1.1| |**operating range factor control supply voltage rated value at**<br>**AC at 60 Hz**|| |● initial value|0.85| |● full-scale value|1.1| |**inrush currentpeak**|| |● at 24 V|2 A| |**duration of inrush currentpeak**|| |● at 24 V|1 ms| |**Switching Function**|| |**switching function**|| |● ON-delay|Yes| |● ON-delay/instantaneous contact|No| |●passingmake contact|No| |●passingmake contact/instantaneous contact|No| |● OFF delay|No| |**switching function**|| |● flashingsymmetricallywith interval start/instantaneous|No| |● flashingsymmetricallywith interval start|No| |● flashingsymmetricallywithpulse start/instantaneous|No| |● flashingsymmetricallywithpulse start|No| |● flashingasymmetricallywith interval start|No| |● flashingasymmetricallywithpulse start|No| |**switching function**|| |● star-delta circuit with delaytime|No| |● star-delta circuit|No| |**switching function with control signal**|| |● additive ON-delay|No| |●passingbreak contact|No| |●passingbreak contact/instantaneous|No| |● OFF delay|No| |● OFF delay/instantaneous|No| |●pulse delayed|No| |●pulse delayed/instantaneous|No| |●pulse-shaping|No| |●pulse-shaping/instantaneous|No| |● additive ON-delay/instantaneous|No| |● ON-delay/OFF-delay/instantaneous|No| |●passingmake contact|No| |●passingmake contact/instantaneous contact|No| |**switching function of interval relay with control signal**|| |● retrotriggerable with deactivated control<br>signal/instantaneous contact|No| |● retrotriggerable with switched-on control signal|No| |● retrotriggerable with switched-on control<br>signal/instantaneous contact|No| |● retriggerable with deactivated control signal|No| |**Short-circuit protection**|| |design of the fuse link for short-circuit protection of the auxiliary<br>switch required|fuse gL/gG: 4 A| Subject to change without notice © Copyright Siemens 3RP25251BB30 Page 2/6 6/3/2026 |**Auxiliary circuit**|**Auxiliary circuit**| |---|---| |**material of switching contacts**|AgSnO2| |**number of NC contacts**|| |● delayed switching|0| |● instantaneous contact|0| |**number of NO contacts**|| |● delayed switching|0| |● instantaneous contact|0| |**number of CO contacts**|| |● delayed switching|2| |● instantaneous contact|0| |**operational current of auxiliary contacts at AC-15**|| |● at 24 V|3 A| |● at 250 V|3 A| |**operational current of auxiliary contacts at DC-13**|| |● at 24 V|1 A| |● at 125 V|0.2 A| |● at 250 V|0.1 A| |**operating frequency with 3RT2 contactor maximum**|5 000 1/h| |**contact reliability of auxiliary contacts**|one incorrect switching operation of 100 million switching operations (17 V, 5<br>mA)| |**contact rating of auxiliary contacts according to UL**|R300 / B300| |**switching capacity current with inductive load**|0.01 ... 3 A| |**Inputs/ Outputs**|| |**product function**|| |● at the relayoutputs switchover delayed/without delay|No| |● non-volatile|No| |**ampacity of the output relay at DC-13**|| |● at 24 V|1 A| |● at 125 V|0.2 A| |**Electromagnetic compatibility**|| |EMC emitted interference accordingto IEC 61812-1|ambience A(industrial sector)| |EMC immunityaccordingto IEC 61812-1|corresponds to degree of severity3| |**conducted interference**|| |● due to burst accordingto IEC 61000-4-4|2 kV network connection / 1 kV control connection| |● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV| |● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV| |**field-based interference according to IEC 61000-4-3**|10 V/m| |**electrostatic discharge according to IEC 61000-4-2**|4 kV contact discharge / 8 kV air discharge| |**Safety related data**|| |categoryaccordingto EN 954-1|none| |Electrical Safety|| |**protection class IP on the front according to IEC 60529**|IP20| |**type of insulation**|Basic insulation| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|Yes| |**type of electrical connection**|screw terminal| |● for auxiliaryand control circuit|screw-type terminals| |**type of connectable conductor cross-sections**|| |● solid|1x(0.5 ... 4 mm²), 2x(0.5 ... 2.5 mm²)| |● finelystranded with core endprocessing|1x(0.5 ... 4 mm²), 2x(0.5 ... 1.5 mm²)| |● for AWG cables solid|1x(20 ... 12), 2x(20 ... 14)| |**connectable conductor cross-section**|| |● solid|0.5 ... 4 mm²| |● finelystranded with core endprocessing|0.5 ... 4 mm²| |**AWG number as coded connectable conductor cross**<br>**section**|| |● solid|20 ... 12| Subject to change without notice © Copyright Siemens 3RP25251BB30 Page 3/6 6/3/2026 |**tightening torque**|**tightening torque**|0.6 ... 0.8 N·m| |---|---|---| |**design of the thread of the connection screw**||M3| |**Installation/ mounting/ dimensions**<br>~~a~~||| |**mounting position**<br>~~a~~||any<br>~~a~~| |**fastening method**||screw and snap-on mountingonto 35 mm DIN rail| |**height**||100 mm| |**width**||22.5 mm| |**depth**||90 mm| |**required spacing**||| |● with side-by-side mounting||| |— forwards||0 mm| |— backwards||0 mm| |— upwards||0 mm| |— downwards||0 mm| |— at the side||0 mm| |● forgroundedparts||| |— forwards||0 mm| |— backwards||0 mm| |— upwards||0 mm| |— at the side||0 mm| |— downwards||0 mm| |● for liveparts||| |— forwards||0 mm| |— backwards||0 mm| |— upwards||0 mm| |— downwards||0 mm| |— at the side||0 mm| |**Ambient conditions**<br>~~a~~||| |installation altitude at height above sea level maximum<br>~~a~~||2 000 m<br>~~a~~| |**ambient temperature**||| |● duringoperation||-25 ... +60 °C| |● duringstorage||-40 ... +85 °C| |● duringtransport||-40 ... +85 °C| |relative humidityduringoperation||10 ... 95 %| |**Approvals Certificates**<br>~~er~~||| |**Environment**<br>~~er~~|**General Product Approval**<br>~~er~~|| Subject to change without notice © Copyright Siemens 3RP25251BB30 Page 4/6 6/3/2026 ## **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RP2525-1BB30 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RP2525-1BB30 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RP2525-1BB30 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RP2525-1BB30&lang=en **==> picture [203 x 225] intentionally omitted <==** Subject to change without notice © Copyright Siemens 3RP25251BB30 Page 5/6 6/3/2026 **==> picture [393 x 316] intentionally omitted <==** **----- Start of picture text -----**<br> -K<br>last modified: 5/29/2026<br>C C<br>A1<br>15 25<br>A2 A2 CN ON CN ON<br>16 18 26 28<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3RP25251BB30 Page 6/6 6/3/2026
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →