Image not available
Illustrative purposes only
3RP15051BW30
Time Delay Relay, 0.15 min, 3 min, SIRIUS 3RP15 Series, DPDT
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Time Delay Relays - Electromechanical
- Contact Voltage VDC:-; Time Min:0.15min; Time Max:3min; Product Range:3RP1 Series; Contact Configuration:DPDT; Contact Current:-; Relay Mounting:DIN Rail; Contact Voltage VAC:-; Relay Termin
- Time Max: 3min
- Time Min: 0.15min
- Product Range: SIRIUS 3RP15 Series
- Relay Mounting: DIN Rail
- Contact Current: -
- Relay Terminals: Screw
- Nom Input Voltage: 240V
- Timing Adjustment: Rotary Switch
- Contact Voltage VAC: -
- Contact Voltage VDC: -
- Contact Configuration: DPDT
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 214.33 € |
| Current stock | 10+ |
| Lead time | 30 days |
3RP15 05-1BW30 Data sheet TIME RELAY, MULTI-FUNCTION 2 CHANGEOVER, 16 FUNCTIONS, 15 TIME SETTING RANGES AC/DC 24... 240 V, WITH LED, SCREW CONNECTION |product brand name||SIRIUS| |---|---|---| |Product designation||timing relay| |Mounting position||any| |Product function non-volatile||No| |Product component||| |● Relay output||Yes| |● semi-conductor output||No| |Installation altitude at height above sea level<br>maximum|m|2 000| |Ambient temperature||| |● during operation|°C|-25 ... +60| |● during storage|°C|-40 ... +85| |● during transport|°C|-40 ... +85| |Relative humidity during operation|%|10 ... 95| |EMC emitted interference acc. to IEC 61812-1||EN 61000-6-4(3)| |EMI immunity acc. to IEC 61812-1||EN 61000-6-2| |Conducted interference due to burst acc. to IEC<br>61000-4-4||2 kV network connection / 1 kV control connection| Changes preserved © Copyright Siemens AG 3RP15 05-1BW30 Page 1/6 16.12.2015 |Conducted interference due to conductor-earth surge<br>acc. to IEC 61000-4-5||2 kV| |---|---|---| |Conducted interference due to conductor-conductor<br>surge acc. to IEC 61000-4-5||1 kV| |Electrostatic discharge acc. to IEC 61000-4-2||4 kV contact discharge / 8 kV air discharge| |Field-bound parasitic coupling acc. to IEC 61000-4-3||10 V/m| |Surge voltage resistance rated value|V|4 000| |Power loss [W] total typical|W|2| |Equipment marking acc. to DIN 40719 extended<br>according to IEC 204-2 acc. to IEC 750||K| |Equipment marking acc. to DIN EN 81346-2||K| |Category acc. to EN 954-1||none| |Protection against electrical shock||finger-safe| |Protection class IP||IP20| |Mechanical service life (switching cycles) typical||10 000 000| |Electrical endurance (switching cycles) at AC-15 at<br>230 V typical||100 000| |Operating frequency with 3RT2 contactor maximum|1/h|5 000| |Vibration resistance acc. to IEC 60068-2-6||10 ... 55 Hz / 0.35 mm| |Shock resistance acc. to IEC 60068-2-27||11g / 15 ms| |Relative repeat accuracy|%|1| |Recovery time|ms|150| |Minimum ON period|ms|35| |Degree of pollution||3| |Insulation voltage for overvoltage category III<br>according to IEC 60664 with degree of pollution 3<br>rated value|V|300| |Relative setting accuracy relating to full-scale value|%|5| |||| |Switching Function:||| |Switching function||| |● ON-delay||Yes| |● ON-delay/instantaneous contact||Yes| |● passing make contact||Yes| |● passing make contact/instantaneous contact||Yes| |● OFF delay||No| |● flashing asymmetrically starting with interval||No| |● flashing asymmetrically starting with pulse||No| |● flashing symmetrically starting with pulse||No| |● flashing symmetrically starting with<br>pulse/instantaneous||No| |● flashing symmetrically starting with interval||Yes| |● flashing symmetrically starting with<br>interval/instantaneous||Yes| |● star-delta circuit||Yes| |||| |---|---|---| |Switching Function:||| |Switching function||| |● ON-delay||Yes| |● ON-delay/instantaneous contact||Yes| |● passing make contact||Yes| |● passing make contact/instantaneous contact||Yes| |● OFF delay||No| |● flashing asymmetrically starting with interval||No| |● flashing asymmetrically starting with pulse||No| |● flashing symmetrically starting with pulse||No| |● flashing symmetrically starting with||No| |pulse/instantaneous||| |● flashing symmetrically starting with interval||Yes| |● flashing symmetrically starting with||Yes| |interval/instantaneous||| |● star-delta circuit||Yes| Changes preserved © Copyright Siemens AG 3RP15 05-1BW30 Page 2/6 16.12.2015 |● star-delta circuit with delay time||No| |---|---|---| |Switching function with control signal||| |● additive ON delay||Yes| |● passing break contact||Yes| |● OFF delay||Yes| |● pulse-shaping||Yes| |● OFF delay/instantaneous||Yes| |● ON-delay/OFF-delay/instantaneous||Yes| |● passing break contact/instantaneous||Yes| |● additive ON delay/instantaneous||Yes| |● ON-delay/OFF-delay||Yes| |● passing make contact||No| |● passing make contact/instantaneous contact||No| |● pulse delayed||No| |● pulse delayed/instantaneous||No| |● pulse-shaping/instantaneous||Yes| |Switching function of interval relay with control signal||| |● retrotriggerable with deactivated control<br>signal/instantaneous contact||No| |● retrotriggerable with activated control signal||No| |● retrotriggerable with activated control<br>signal/instantaneous contact||No| |● retriggerable with deactivated control signal||No| |Design of the control terminal non-floating||Yes| |||| |Control circuit/ Control:||| |Adjustable time|s|0.05 ... 360 000| |Type of voltage of the control supply voltage||AC/DC| |Control supply voltage frequency 1|Hz|50 ... 60| |Control supply voltage 1||| |● at AC||| |— at 50 Hz|V|24 ... 240| |— at 60 Hz|V|24 ... 240| |● at DC|V|24 ... 240| |Operating range factor control supply voltage rated<br>value||| |● at AC||| |— at 50 Hz||0.8 ... 1.1| |— at 60 Hz||0.8 ... 1.1| |● at DC||0.7 ... 1.1| |||| |Auxiliary circuit:||| |Contact reliability of auxiliary contacts||one incorrect switching operation of 100 million<br>switching operations (17 V, 5 mA)| Changes preserved © Copyright Siemens AG 3RP15 05-1BW30 Page 3/6 16.12.2015 |Material of switching contacts||AgSnO2| |---|---|---| |Operating current of auxiliary contacts||| |● at AC-15||| |— at 24 V|A|3| |— at 250 V|A|3| |● at DC-13||| |— at 24 V|A|1| |— at 125 V|A|0.2| |— at 250 V|A|0.1| |Design of the fuse link for short-circuit protection of<br>the auxiliary switch required||fuse gL/gG: 4 A| |Thermal current|A|5| |Number of NC contacts||| |● delayed switching||0| |● instantaneous contact||0| |Number of NO contacts||| |● delayed switching||0| |● instantaneous contact||0| |Number of CO contacts||| |● delayed switching||2| |● instantaneous contact||0| |||| |Installation/ mounting/ dimensions:||| |Mounting type||screw and snap-on mounting onto 35 mm standard<br>mounting rail| |Width|mm|22.5| |Height|mm|102| |Depth|mm|91| |Required spacing with side-by-side mounting||| |● upwards|mm|0| |● forwards|mm|0| |● at the side|mm|0| |● Backwards|mm|0| |● downwards|mm|0| |Required spacing for grounded parts||| |● Backwards|mm|0| |● at the side|mm|0| |● upwards|mm|0| |● forwards|mm|0| |● downwards|mm|0| |Required spacing for live parts||| |● downwards|mm|0| |● Backwards|mm|0| Changes preserved © Copyright Siemens AG 3RP15 05-1BW30 Page 4/6 16.12.2015 ● at the side mm 0 ● forwards mm 0 ● upwards mm 0 Connections/ Terminals: Type of electrical connection for auxiliary and control screw-type terminals current circuit Type of connectable conductor cross-sections ● solid 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²) ● finely stranded — with core end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) ● at AWG conductors — stranded 2x (20 ... 14) — solid 2x (20 ... 14) Tightening torque N·m 0.8 ... 1.2 Certificates/ approvals: General Product Approval Declaration of Test Conformity Certificates spezielle Prüfbescheinigunge n ccc CSA E H [ UL EG-Konf. Shipping Approval pe SD LN fe =) a TW... J “> v, Sd = egister girs 7828 ——— Se 4 sé ~S DNV GL LRS PRS RINA Shipping other Approval Bestätigungen sonstig Umweltbestätigung RMRS Further information Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/industrial-controls/catalogs Industry Mall (Online ordering system) http://www.siemens.com/industrymall Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RP15051BW30 Changes preserved © Copyright Siemens AG 3RP15 05-1BW30 Page 5/6 16.12.2015 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RP15051BW30 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RP15051BW30&lang=en **==> picture [303 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> 86<br>65<br>23 5 36<br>4 7<br>last modified: 08.12.2015<br>92<br>87 68 120 74 83 102<br>110x15<br>**----- End of picture text -----**<br> Changes preserved © Copyright Siemens AG 3RP15 05-1BW30 Page 6/6 16.12.2015
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →