- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: 3 Pole
- Power Rating: 60W
- No. of Phases: Three Phase
- Product Range: SIMATIC ET 200S
- Current Rating: 200mA
- IP / NEMA Rating: IP20
- Motor Starter Type: Reversing Starter
- Supply Voltage Max: 440VAC
- Supply Voltage Min: 200VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 241.5 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RK1301-0BB00-1AA2** **Data sheet** RS1-X for ET 200S Standard reversing starter expandable Setting range 0.14...0.2 A, AC-3, up to 0.06 kW / 400 V Electromechanical starter for brake control module ||<br>Lit<br>Figure similar|RS1-X for ET 200S Standard reversing starter expandable Setting range 0.14...0.2<br>A, AC-3, up to 0.06 kW / 400 V Electromechanical starter for brake control module| |---|---| |**product brand name**|SIMATIC| |**product designation**|Motor starters| |**design of theproduct**|reversingstarter| |**product type designation**|ET 200S| |**General technical data**|| |product function on-site operation|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|9 W| |● at AC in hot operatingstateperpole|3 W| |● without load current share typical|4.12 W| |**insulation voltage rated value**|500 V| |**degree ofpollution**|3 at 400 V, 2 at 500 V accordingto IEC60664(IEC61131)| |**surge voltage resistance rated value**|6 kV| |maximum permissible voltage for protective separation between<br>main and auxiliarycircuit|400 V| |**shock resistance**|5g/ 11 ms| |**vibration resistance**|2g| |**operating frequency maximum**|750 1/h| |mechanical service life (operating cycles) of the main contacts<br>typical|100 000| |**type of coordination**|2| |**reference code according to IEC 81346-2**|Q| |**Substance Prohibitance(day/month/year)**|10/26/2016| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1| |**Net Weight**|1.277 kg| |**product function**|| |● direct start|No| |● reverse starting|Yes| |**product component motor brake output**|Yes| |**product feature**|| |● brake control with 230 V AC|No| |● brake control with 24 V DC|No| |● brake control with 180 V DC|No| |● brake control with 500 V DC|No| |**product extension braking module for brake control**|Yes| |**product function short circuit protection**|Yes| Subject to change without notice © Copyright Siemens 3RK13010BB001AA2 Page 1/5 5/31/2026 ||**design of short-circuitprotection**|circuit-breakers|| |---|---|---|---| ||**maximum short-circuit current breaking capacity (Icu)**||| ||● at 400 V rated value|50 kA|| ||**Electromagnetic compatibility**||| ||EMC emitted interference accordingto IEC 60947-1|CISPR11, ambience A(industrial sector)|| ||EMC immunityaccordingto IEC 60947-1|corresponds to degree of severity3, ambience A(industrial sector)|| ||**conducted interference**||| ||● due to burst accordingto IEC 61000-4-4|2 kV on voltage supply, inputs and outputs|| ||● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV(U > 24 V DC)|| ||● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV (U > 24 V DC)|| ||**field-based interference according to IEC 61000-4-3**|80 MHz ... 1 GHz 10 V/m, 1.4 GHz ...2 Hz 3 V/m, 2 GHz ... 2.7 GHz 1 V/m|| ||**Safety related data**||| ||**proportion of dangerous failures**||| ||● with low demand rate accordingto SN 31920|50 %|| ||● with high demand rate accordingto SN 31920|75 %|| ||**B10 value with high demand rate according to SN 31920**|1 000 000|| ||**failure rate [FIT] with low demand rate according to SN**<br>**31920**|100 FIT|| ||IEC 61508||| ||T1 value for proof test interval or service life according to IEC<br>61508|20 a|| ||Electrical Safety||| ||**protection class IP on the front according to IEC 60529**|IP20|| ||**touch protection on the front according to IEC 60529**|finger-safe|| ||**Main circuit**||| ||**number ofpoles for main current circuit**|3|| ||**design of the switching contact**|electromechanical|| ||**adjustable current response value current of the current-**<br>**dependent overload release**|0.14 ... 0.2 A|| ||**type of the motorprotection**|bimetal|| ||operatingvoltage rated value|200 ... 400 V|| ||**operating frequency 1 rated value**|50 Hz|| ||**operating frequency 2 rated value**|60 Hz|| ||**relativepositive tolerance of the operating frequency**|10 %|| ||**relative negative tolerance of the operating frequency**|10 %|| ||operatingrange relative to the operatingvoltage at AC at 50 Hz|200 ... 440 V|| ||**operational current**||| ||● at AC-3 at 400 V rated value|0.2 A|| ||operating power at AC-3 at 400 V rated value|0.06 kW|| ||operatingpower for 3-phase motors at 400 V at 50 Hz|0.06 kW|| ||**Inputs/ Outputs**||| ||**product function**||| ||● digital inputsparameterizable|No|| ||● digital outputsparameterizable|No|| ||**number of digital inputs**|0|| ||**number of sockets**||| ||● for digital output signals|0|| ||● for digital input signals|0|| ||**Supply voltage**||| ||**type of voltage of the supply voltage**|DC|| ||**supply voltage 1 at DC**|24 V|| ||**supply voltage 1 at DC rated value**||| ||● minimumpermissible|20.4 V|| ||● maximum permissible|28.8 V|| ||**Control circuit/ Control**||| ||**type of voltage of the control supply voltage**|DC|| ||**control supply voltage at DC rated value**|20.4 ... 28.8 V|| ||**control supply voltage 1 at DC rated value**|20.4 ... 28.8 V|| ||**control supply voltage 1 at DC**|24 V|| Subject to change without notice © Copyright Siemens 3RK13010BB001AA2 Page 2/5 5/31/2026 |**power loss[W] in auxiliary and control circuit**||| |---|---|---| |**● in switching state OFF**||| |— with bypass circuit|0.3744 W|| |— without bypass circuit|0.374 W|| |**● in switching state ON**||| |— with bypass circuit|4.1184 W|| |— without bypass circuit|4.118 W|| |**Installation/ mounting/ dimensions**<br>~~|~~||| |**mounting position**<br>~~|~~|vertical, horizontal<br>~~|~~|| |**fastening method**|pluggable on terminal module|| |**height**<br>~~OS~~|265 mm|| |**width**<br>~~OS~~|90 mm|| |**depth**<br>~~OS~~|120 mm|| |**Ambient conditions**||| |installation altitude at height above sea level maximum|2 000 m|| |**ambient temperature**||| |● duringoperation|0 ... 60 °C|| |● duringstorage|-40 ... +70 °C|| |● duringtransport<br>~~a~~|-40 ... +70 °C<br>~~a~~|| |relative humidityduringoperation<br>~~a~~|5 ... 95 %<br>~~a~~|| |**Communication/ Protocol**||| |**protocol is supported**||| |● PROFIBUS DPprotocol|Yes|| |● PROFINETprotocol|Yes|| |design of the interface PROFINETprotocol|Yes|| |**product function bus communication**|Yes|| |protocol is supported AS-Interfaceprotocol|No|| |**product function**||| |● supports PROFIenergymeasured values|No|| |● supports PROFIenergyshutdown|No|| |**address space memory of address range**||| |● of the inputs|1 byte|| |● of the outputs|1 byte|| |**type of electrical connection**||| |● of the communication interface|via backplane bus|| |● for communication transmission|via backplane bus|| |**Connections/ Terminals**<br>~~|~~||| |type of electrical connection for main current circuit<br>~~|~~|screw-type terminals<br>~~|~~|| |**type of electrical connection**||| |● 1 for digital input signals|usingcontrol module|| |● 2 for digital input signals|usingcontrol module|| |**type of electrical connection**||| |● at the manufacturer-specific device interface|plug|| |● for main energyinfeed|screw-type terminals|| |● for load-side outgoingfeeder|Screw-type terminals|| |● for main energytransmission|via energybus|| |● for supplyvoltage line-side|via backplane bus|| |● for supplyvoltage transmission|via backplane bus|| |**UL/CSA ratings**<br>~~|~~||| |operating voltage at AC at 60 Hz according to CSA and UL<br>rated value<br>~~|~~|600 V<br>~~|~~|| |**Approvals Certificates**<br>~~a~~||| |**General Product Approval**<br>~~a~~||**EMV**<br>~~a~~| ~~|~~ **UL/CSA ratings** operating voltage at AC at 60 Hz according to CSA and UL 600 V rated value ~~a~~ **Approvals Certificates General Product Approval EMV** Subject to change without notice © Copyright Siemens 3RK13010BB001AA2 Page 3/5 5/31/2026 **For use in hazardous locations Test Certificates other Dangerous goods Environment** Type Test CertificConfirmation Transport Information Environmental Conates/Test Report firmations n ~~n:~~ ~~i~~ **Further information** ~~‘~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RK1301-0BB00-1AA2 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RK1301-0BB00-1AA2 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RK1301-0BB00-1AA2 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RK1301-0BB00-1AA2&lang=en **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> Subject to change without notice © Copyright Siemens 3RK13010BB001AA2 Page 4/5 5/31/2026 **==> picture [240 x 336] intentionally omitted <==** **----- Start of picture text -----**<br> -Q1<br>A id<br>I> I> I><br>Logic<br>K1 K2<br>K2<br>K1<br>L1 L2 L3<br>1 2 3<br>T T T<br>**----- End of picture text -----**<br> **last modified:** 4/4/2026 Subject to change without notice © Copyright Siemens 3RK13010BB001AA2 Page 5/5 5/31/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →