Image not available
Illustrative purposes only
3RA6400-1BB43
Compact Starter, Direct On Line, 3RA6 Series, Three Phase, 1.25 A, 690 V, Plug-in
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: 3 Pole
- Power Rating: 370W
- No. of Phases: Three Phase
- Product Range: 3RA6400
- Current Rating: 1.25A
- IP / NEMA Rating: IP20
- Motor Starter Type: Direct-on-Line (DOL) Starter
- Supply Voltage Max: 690VAC
- Supply Voltage Min: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 518.96 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RA6400-1BB43** **Data sheet** ***phase-out type*** compact starter direct-on-line starter for IO-Link 690 V 24 V DC 0.32...1.25 A IP20 connection main circuit: plug-in, without terminals connection control circuit: screw terminal alternative 3RK1308 or 3RA8 requirement controller such as ET 200SP in use ||***phase-out type*** compact starter direct-on-line starter for IO-Link 690 V 24 V<br>DC 0.32...1.25 A IP20 connection main circuit: plug-in, without terminals<br>connection control circuit: screw terminal alternative 3RK1308 or 3RA8<br>requirement controller such as ET 200SP in use| |---|---| |**product brand name**|SIRIUS| |**product designation**|Compact starter for IO-Link| |**design of theproduct**|direct starter| |**product type designation**|3RA64| |**General technical data**<br>~~|~~|| |product function control circuit interface toparallel wiring<br>~~|~~|No<br>~~|~~| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|0.1 W| |● at AC in hot operatingstateperpole|0.03 W| |● without load current share typical|2.9 W| |**insulation voltage rated value**|690 V| |**degree ofpollution**|3| |**surge voltage resistance rated value**|6 000 V| |**degree ofprotection NEMA rating**|other| |**shock resistance**|a=60 m/s2(6g)with 10 msper 3 shocks in all axes| |**vibration resistance**|f = 4 ... 5.8 Hz, d = 15 mm; f = 5.8 ... 500 Hz, a = 20 m/s²; 10 cycles| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|10 000 000| |● of auxiliarycontacts typical|10 000 000| |● of the signalingcontacts typical|10 000 000| |**electrical endurance(operating cycles) of auxiliary contacts**|| |● at DC-13 at 6 A at 24 V typical|30 000| |● at AC-15 at 6 A at 230 V typical|200 000| |**type of coordination**|continous operation accordingto IEC 60947-6-2| |**reference code according to IEC 81346-2**|Q| |**Substance Prohibitance(day/month/year)**|05/01/2012| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-(2H-benzotriazol-2-yl)-4-(1,1,3,3-tetramethylbutyl)phenol (UV-329) CAS-No.<br>3147-75-9<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1| |**Net Weight**|1.404 kg| |**Ambient conditions**<br>~~|~~|| |installation altitude at height above sea level maximum<br>~~|~~|2 000 m<br>~~|~~| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● during storage|-55 ... +80 °C| |**Net Weight**|1.404 kg| |---|---| |**Ambient conditions**<br>~~|~~|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● during storage|-55 ... +80 °C| Subject to change without notice © Copyright Siemens 3RA64001BB43 Page 1/6 5/29/2026 |● duringtransport|-55 ... +80 °C| |---|---| |relative humidityduringoperation|10 ... 90 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**<br>**dependent overload release**|0.32 ... 1.25 A| |**formula for making capacity limit current**|38.4 x Ie| |**formula for limit current breaking capacity**|32 x Ie| |**yielded mechanicalperformance for 4-pole AC motor**|| |● at 400 V rated value|0.37 kW| |● at 500 V rated value|0.55 kW| |● at 690 V rated value|0.75 kW| |operatingvoltage at AC-3 rated value maximum|690 V| |**operational current**|| |● at AC at 400 V rated value|1.25 A| |● at AC-3 at 400 V rated value|1.25 A| |● at AC-43|| |— at 400 V rated value|1.1 A| |— at 500 V rated value|1.2 A| |— at 690 V rated value|1.1 A| |**operating power**|| |● at AC-3 at 400 V rated value|0.37 kW| |● at AC-43|| |— at 400 V rated value|370 W| |— at 500 V rated value|550 W| |— at 690 V rated value|750 W| |**no-load switching frequency**|3 600 1/h| |**operating frequency**|| |● at AC-41 accordingto IEC 60947-6-2 maximum|750 1/h| |● at AC-43 accordingto IEC 60947-6-2 maximum|250 1/h| |**Control circuit/ Control**|| |**type of voltage**|DC| |**control supply voltage 1 at DC rated value**|24 V| |**control supply voltage 1 at DC**|24 V| |**holding power**|| |● at DC maximum|2.9 W| |**Auxiliary circuit**|| |**number of NC contacts for auxiliary contacts**|0| |**number of NO contacts for auxiliary contacts**|0| |number of NO contacts of instantaneous short-circuit trip unit for<br>signalingcontact|0| |number of CO contacts of the current-dependent overload<br>release for signalingcontact|0| |**operational current of auxiliary contacts at AC-12 maximum**|10 A| |operational current of auxiliarycontacts at DC-13 at 250 V|0.27 A| |**Protective and monitoring functions**|| |**trip class**|CLASS 10 and 20 adjustable| |**operating short-circuit current breaking capacity (Ics)**|| |● at 400 V rated value|53 kA| |● at 500 V rated value|3 kA| |● at 690 V rated value|3 kA| |**UL/CSA ratings**|| |**full-load current(FLA) for 3-phase AC motor**|| |● at 480 V rated value|1.25 A| |● at 600 V rated value|1.25 A| |yielded mechanicalperformance[hp]for 3-phase AC motor|| |● at 460/480 V rated value|0.5 hp| |● at 575/600 V rated value|0.5 hp| |**Short-circuit protection**|| Subject to change without notice © Copyright Siemens 3RA64001BB43 Page 2/6 5/29/2026 |**product function short circuitprotection**|Yes| |---|---| |**design of short-circuitprotection**|electromagnetic| |**design of the fuse link**|| |● for short-circuit protection of the auxiliaryswitch required|fusegL/gG: 10 A| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**mounting position recommended**|vertical, on horizontal standard DIN rail| |**fastening method**|screw and snap-on mounting| |**height**|170 mm| |**width**|45 mm| |**depth**|165 mm| |**Connections/ Terminals**|| |**product component removable terminal for main circuit**|Yes| |**product component removable terminal for auxiliary and**<br>**control circuit**|Yes| |**type of electrical connection**|| |● for main current circuit|plug-in without terminals| |● for auxiliaryand control circuit|screw-type terminals| |type of connectable conductor cross-sections for main contacts|| |● solid|2x(1.5 ... 6 mm²), 1x 10 mm²| |● finelystranded with core endprocessing|2x(1.5 ... 6 mm²)| |**type of connectable conductor cross-sections**|| |● for auxiliarycontacts|| |— solid|0.5 ... 4 mm², 2x(0.5 ... 2.5 mm²)| |— finelystranded with core endprocessing|0.5 ... 2.5 mm², 2x(0.5 ... 1.5 mm²)| |● for AWG cables for auxiliarycontacts|2x(20 ... 14)| |**Safety related data**|| |**proportion of dangerous failures**|| |● with high demand rate accordingto SN 31920|50 %| |**B10 value with high demand rate according to SN 31920**|3 000 000| |Electrical Safety|| |**protection class IP on the front according to IEC 60529**|IP20| |**touch protection on the front according to IEC 60529**|finger-safe| |**Communication/ Protocol**|| |**product function bus communication**|Yes| |**protocol is supported**|| |● AS-Interfaceprotocol|No| |● IO-Linkprotocol|Yes| |product function control circuit interface with IO link|Yes| |**IO-Link transfer rate**|COM2(38,4 kBaud)| |**point-to-point cycle time between master and IO-Link**<br>**device minimum**|2.5 ms| |**type of voltage supply via input/output link master**|No| |**data volume**|| |● of the address range of the inputs with cyclical transfer<br>total|2 byte| |● of the address range of the outputs with cyclical transfer<br>total|2 byte| |**Electromagnetic compatibility**|| |**conducted interference**|| |● due to burst according to IEC 61000-4-4|4 kV main circuits, 2 kV auxiliary circuits, 2 kV IO-Link, 2 kV limit switches, 2 kV<br>line hand-held device| |● due to conductor-earth surge according to IEC 61000-4-5|4 kV main circuits, 0.5 kV auxiliary voltage with upstream overvoltage<br>protection| |● due to conductor-conductor surge according to IEC<br>61000-4-5|2 kV main circuits, 0.5 kV auxiliary voltage with upstream overvoltage<br>protection| |● due to high-frequency radiation according to IEC 61000-<br>4-6|0.15-80Mhz at 10V| |**field-based interference according to IEC 61000-4-3**|80 ... 3000 MHz at 10V/m| |**electrostatic discharge according to IEC 61000-4-2**|8 kV| |**conducted HF interference emissions according to**|150 kHz ... 30 MHz Class A| Subject to change without notice © Copyright Siemens 3RA64001BB43 Page 3/6 5/29/2026 **CISPR11** ~~re~~ **field-bound HF interference emission according to CISPR11** 30 ... 1000 MHz Class A **Supply voltage Supply voltage required Auxiliary voltage** Yes ~~|~~ **Display number of LEDs** 3 display version as status display of the input/output link device green/red dual LED ~~ee~~ **Approvals Certificates Environment General Product Approval** Environmental Confirmations ~~—~~ @ fA Se && **EMV Functional Saftey Test Certificates other** Type Examination CerType Test CertificConfirmation Confirmation tificate ates/Test Report QT ~~acs~~ **Dangerous goods** Transport Information ~~OO—CsrSC“‘:CC‘isCs~~ **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RA6400-1BB43 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RA6400-1BB43 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RA6400-1BB43&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RA6400-1BB43 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> Subject to change without notice © Copyright Siemens 3RA64001BB43 Page 4/6 5/29/2026 **==> picture [511 x 360] intentionally omitted <==** Subject to change without notice © Copyright Siemens 3RA64001BB43 Page 5/6 5/29/2026 **last modified:** 4/4/2026 Subject to change without notice © Copyright Siemens 3RA64001BB43 Page 6/6 5/29/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.