Image not available
Illustrative purposes only
3RA6120-2CP32
Compact Starter, Direct On Line, 3RA6 Series, Three Phase, 4 A, 690 V, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: 3 Pole
- Power Rating: 1.5kW
- No. of Phases: Three Phase
- Product Range: 3RA6120
- Current Rating: 4A
- IP / NEMA Rating: IP20
- Motor Starter Type: Direct-on-Line (DOL) Starter
- Supply Voltage Max: 690VAC
- Supply Voltage Min: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 344.77 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RA6120-2CP32** **Data sheet** SIRIUS Compact load feeder DOL starter 690 V 110...240 V AC/DC 50...60 Hz 1...4 A IP20 Connection main circuit: Spring-type terminal Connection auxiliary circuit: Spring-type terminal ||SIRIUS Compact load feeder DOL starter 690 V 110...240 V AC/DC 50...60 Hz<br>1...4 A IP20 Connection main circuit: Spring-type terminal Connection auxiliary<br>circuit: Spring-type terminal| |---|---| |**product brand name**|SIRIUS| |**product designation**|compact starter| |**design of theproduct**|direct starter| |**product type designation**|3RA61| |**General technical data**<br>~~|~~|| |product function control circuit interface toparallel wiring<br>~~|~~|Yes<br>~~|~~| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|1 W| |● at AC in hot operatingstateperpole|0.33 W| |● without load current share typical|6 W| |**insulation voltage rated value**|690 V| |**degree ofpollution**|3| |**surge voltage resistance rated value**|6 000 V| |**maximumpermissible voltage forprotective separation**|| |● between main and auxiliarycircuit|400 V| |● between auxiliaryand auxiliarycircuit|250 V| |● between control and auxiliarycircuit|300 V| |**degree ofprotection NEMA rating**|other| |**shock resistance**|a=60 m/s2(6g)with 10 msper 3 shocks in all axes| |**vibration resistance**|f = 4 ... 5.8 Hz, d = 15 mm; f = 5.8 ... 500 Hz, a = 20 m/s²; 10 cycles| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|10 000 000| |● of auxiliarycontacts typical|10 000 000| |● of the signalingcontacts typical|10 000 000| |**electrical endurance(operating cycles) of auxiliary contacts**|| |● at DC-13 at 6 A at 24 V typical|30 000| |● at AC-15 at 6 A at 230 V typical|200 000| |**type of coordination**|continous operation accordingto IEC 60947-6-2| |**reference code according to IEC 81346-2**|Q| |**Substance Prohibitance(day/month/year)**|05/01/2012| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-(2H-benzotriazol-2-yl)-4-(1,1,3,3-tetramethylbutyl)phenol (UV-329) CAS-No.<br>3147-75-9<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1| |**Net Weight**|1.492 kg| |**Ambient conditions**<br>~~|~~|| |installation altitude at height above sea level maximum<br>~~|~~|2 000 m<br>~~|~~| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-55 ... +80 °C| |● duringtransport|-55 ... +80 °C| |relative humidityduringoperation|10 ... 90 %| |**Main circuit**<br>~~|~~|| |**number ofpoles for main current circuit**<br>~~|~~|3<br>~~|~~| |**adjustable current response value current of the current-**<br>**dependent overload release**|1 ... 4 A| |**Net Weight**|1.492 kg| |---|---| |**Ambient conditions**<br>~~|~~|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-55 ... +80 °C| |● duringtransport|-55 ... +80 °C| |relative humidityduringoperation|10 ... 90 %| |**Main circuit**<br>~~|~~|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**|1 ... 4 A| |**dependent overload release**|| 3RA61202CP32 Page 1/4 Subject to change without notice © Copyright Siemens 5/30/2026 |**formula for making capacity limit current**|12 x Ie| |---|---| |**formula for limit current breaking capacity**|10 x Ie| |**yielded mechanicalperformance for 4-pole AC motor**|| |● at 400 V rated value|1.5 kW| |● at 500 V rated value|2.2 kW| |● at 690 V rated value|3 kW| |operatingvoltage at AC-3 rated value maximum|690 V| |**operational current**|| |● at AC at 400 V rated value|4 A| |● at AC-3 at 400 V rated value|4 A| |● at AC-43|| |— at 400 V rated value|3.6 A| |— at 500 V rated value|3.9 A| |— at 690 V rated value|3.8 A| |**operating power**|| |● at AC-3 at 400 V rated value|1.5 kW| |● at AC-43|| |— at 400 V rated value|1 500 W| |— at 500 V rated value|2 200 W| |— at 690 V rated value|3 000 W| |**no-load switching frequency**|3 600 1/h| |**operating frequency**|| |● at AC-41 accordingto IEC 60947-6-2 maximum|750 1/h| |● at AC-43 accordingto IEC 60947-6-2 maximum|250 1/h| |**Control circuit/ Control**|| |**type of voltage**|AC/DC| |**control supply voltage 1 at AC**|| |● at 50 Hz rated value|240 V| |● at 50 Hz|110 ... 240 V| |● at 60 Hz|110 ... 240 V| |**control supply voltage frequency**|| |**● 1 rated value**|50 Hz| |**● 2 rated value**|60 Hz| |**control supply voltage 1 at DC rated value**|240 V| |**control supply voltage 1 at DC**|110 ... 240 V| |**holding power**|| |● at AC maximum|6 W| |● at DC maximum|5.1 W| |**Auxiliary circuit**|| |**number of NC contacts for auxiliary contacts**|1| |**number of NO contacts for auxiliary contacts**|1| |number of NO contacts of instantaneous short-circuit trip unit for<br>signalingcontact|1| |number of CO contacts of the current-dependent overload<br>release for signalingcontact|1| |**operational current of auxiliary contacts at AC-12 maximum**|10 A| |operational current of auxiliarycontacts at DC-13 at 250 V|0.27 A| |**Protective and monitoring functions**|| |**trip class**|CLASS 10 and 20 adjustable| |**operating short-circuit current breaking capacity (Ics)**|| |● at 400 V rated value|53 kA| |● at 500 V rated value|3 kA| |● at 690 V rated value|3 kA| |**UL/CSA ratings**|| |**full-load current(FLA) for 3-phase AC motor**|| |● at 480 V rated value|4 A| |● at 600 V rated value|4 A| |yielded mechanicalperformance[hp]for 3-phase AC motor|| |● at 200/208 V rated value|0.75 hp| 3RA61202CP32 Page 2/4 Subject to change without notice © Copyright Siemens 5/30/2026 |● at 220/230 V rated value|0.75 hp| |---|---| |● at 460/480 V rated value|2 hp| |● at 575/600 V rated value|3 hp| |**contact rating of auxiliary contacts according to UL**|contacts 21-22, 13-14, 43-44 Q600 / A600, contacts 77-78 R300 / B300,<br>contacts 95-96-98 R300 / D300| |**Short-circuit protection**|| |**product function short circuitprotection**|Yes| |**design of short-circuitprotection**|electromagnetic| |**design of the fuse link**|| |● for short-circuitprotection of the auxiliaryswitch required|fusegL/gG: 10 A| |● for short-circuit protection of the signaling switch of the<br>short-circuit release required|6A gL/gG/400V| |● for short-circuit protection of the signaling switch of the<br>overload release required|4A gL/gG/400V| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**mounting position recommended**|vertical, on horizontal standard DIN rail| |**fastening method**|screw and snap-on mounting| |**height**|191 mm| |**width**|45 mm| |**depth**|165 mm| |**Connections/ Terminals**|| |**product component removable terminal for main circuit**|Yes| |**product component removable terminal for auxiliary and**<br>**control circuit**|Yes| |**type of electrical connection**|| |● for main current circuit|spring-loaded terminals| |● for auxiliaryand control circuit|spring-loaded terminals| |type of connectable conductor cross-sections for main contacts|| |● solid|2x(1.5 ... 6 mm²), 1x 10 mm²| |● finelystranded with core endprocessing|2x(1.5 ... 6 mm²)| |● finelystranded without core endprocessing|2x(1.5 ... 6 mm²)| |**type of connectable conductor cross-sections**|| |● for auxiliarycontacts|| |— solid|2x(0.25 ... 1.5 mm²)| |— finelystranded with core endprocessing|2x(0.25 ... 1.5 mm²)| |— finelystranded without core endprocessing|2x(0.25 ... 1.5 mm²)| |● for AWG cables for auxiliarycontacts|2x(24 ... 16)| |**Safety related data**|| |**proportion of dangerous failures**|| |● with low demand rate accordingto SN 31920|40 %| |● with high demand rate accordingto SN 31920|50 %| |**B10 value with high demand rate according to SN 31920**|3 000 000| |**failure rate [FIT] with low demand rate according to SN**<br>**31920**|100 FIT| |IEC 61508|| |T1 value for proof test interval or service life according to IEC<br>61508|20 a| |Electrical Safety|| |**protection class IP on the front according to IEC 60529**|IP20| |**touch protection on the front according to IEC 60529**|finger-safe| |**Communication/ Protocol**|| |**product function bus communication**|No| |**protocol is supported**|| |● AS-Interfaceprotocol|No| |● IO-Linkprotocol|No| |product function control circuit interface with IO link|No| |**Electromagnetic compatibility**|| |**conducted interference**|| |● due to burst according to IEC 61000-4-4|4 kV main contacts, 2 kV auxiliary contacts| 3RA61202CP32 Page 3/4 Subject to change without notice © Copyright Siemens 5/30/2026 ● due to conductor-earth surge according to IEC 61000-4-5 4 kV main contacts, 2 kV auxiliary contacts ● due to conductor-conductor surge according to IEC 2 kV main contacts, 1 kV auxiliary contacts 61000-4-5 ● due to high-frequency radiation according to IEC 610000.15-80Mhz at 10V 4-6 **field-based interference according to IEC 61000-4-3** 10 V/m **electrostatic discharge according to IEC 61000-4-2** 8 kV **conducted HF interference emissions according to** 150 kHz ... 30 MHz Class A **CISPR11** ~~re~~ **field-bound HF interference emission according to CISPR11** 30 ... 1000 MHz Class A **Supply voltage Supply voltage required Auxiliary voltage** No ~~a~~ **Display number of LEDs** 2 ~~a~~ **Approvals Certificates Environment General Product Approval** Environmental Confirmations ~~—~~ Qu EAL =Cé **General Product ApEMV Functional Saftey Test Certificates Maritime application other proval** Type Examination CerType Test CertificConfirmation tificate ates/Test Report caUK & ~~——_ =~~ a ~~——~~ **other Dangerous goods** Confirmation ~~_ a~~ Transport Information QC PASS ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RA6120-2CP32 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RA6120-2CP32 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RA6120-2CP32&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RA6120-2CP32 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **last modified:** 4/4/2026 3RA61202CP32 Page 4/4 Subject to change without notice © Copyright Siemens 5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →