- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: 3 Pole
- Power Rating: 15kW
- No. of Phases: Three Phase
- Product Range: 3RA6120
- Current Rating: 32A
- IP / NEMA Rating: IP20
- Motor Starter Type: Direct-on-Line (DOL) Starter
- Supply Voltage Max: 690VAC
- Supply Voltage Min: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 513.53 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RA6120-0EB30** **Data sheet** SIRIUS Compact load feeder DOL starter 690 V 24 V AC/DC 50...60 Hz 8...32 A IP20 Connection main circuit: plug-in, without terminals Connection auxiliary circuit: plug-in, without terminals ||SIRIUS Compact load feeder DOL starter 690 V 24 V AC/DC 50...60 Hz 8...32 A<br>IP20 Connection main circuit: plug-in, without terminals Connection auxiliary circuit:<br>plug-in, without terminals| |---|---| |**product brand name**|SIRIUS| |**product designation**|compact starter| |**design of theproduct**|direct starter| |**product type designation**|3RA61| |**General technical data**<br>~~|~~|| |product function control circuit interface toparallel wiring<br>~~|~~|Yes<br>~~|~~| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|5.4 W| |● at AC in hot operatingstateperpole|1.8 W| |● without load current share typical|3.5 W| |**insulation voltage rated value**|690 V| |**degree ofpollution**|3| |**surge voltage resistance rated value**|6 000 V| |**maximumpermissible voltage forprotective separation**|| |● between main and auxiliarycircuit|400 V| |● between auxiliaryand auxiliarycircuit|250 V| |● between control and auxiliarycircuit|300 V| |**degree ofprotection NEMA rating**|other| |**shock resistance**|a=60 m/s2(6g)with 10 msper 3 shocks in all axes| |**vibration resistance**|f = 4 ... 5.8 Hz, d = 15 mm; f = 5.8 ... 500 Hz, a = 20 m/s²; 10 cycles| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|10 000 000| |● of auxiliarycontacts typical|10 000 000| |● of the signalingcontacts typical|10 000 000| |**electrical endurance(operating cycles) of auxiliary contacts**|| |● at DC-13 at 6 A at 24 V typical|30 000| |● at AC-15 at 6 A at 230 V typical|200 000| |**type of coordination**|continous operation accordingto IEC 60947-6-2| |**reference code according to IEC 81346-2**|Q| |**Substance Prohibitance(day/month/year)**|05/01/2012| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-(2H-benzotriazol-2-yl)-4-(1,1,3,3-tetramethylbutyl)phenol (UV-329) CAS-No.<br>3147-75-9<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1| |**Net Weight**<br>~~OO~~|1.399 kg| |**Ambient conditions**<br>~~OO~~<br>~~—“C:isSCSC—i‘“CSNC(C(‘(]KNSCOis~~|| Subject to change without notice © Copyright Siemens 3RA61200EB30 Page 1/7 5/30/2026 ||installation altitude at height above sea level maximum|2 000 m|| |---|---|---|---| ||**ambient temperature**||| ||● duringoperation|-20 ... +60 °C|| ||● duringstorage|-55 ... +80 °C|| ||● duringtransport|-55 ... +80 °C|| ||relative humidityduringoperation|10 ... 90 %|| ||**Main circuit**||| ||**number ofpoles for main current circuit**|3|| ||**adjustable current response value current of the current-**<br>**dependent overload release**|8 ... 32 A|| ||**formula for making capacity limit current**|12 x Ie|| ||**formula for limit current breaking capacity**|10 x Ie|| ||**yielded mechanicalperformance for 4-pole AC motor**||| ||● at 400 V rated value|15 kW|| ||● at 500 V rated value|11 kW|| ||● at 690 V rated value|11 kW|| ||operatingvoltage at AC-3 rated value maximum|690 V|| ||**operational current**||| ||● at AC at 400 V rated value|32 A|| ||● at AC-3 at 400 V rated value|32 A|| ||● at AC-43||| ||— at 400 V rated value|29 A|| ||— at 500 V rated value|17.6 A|| ||— at 690 V rated value|12.8 A|| ||**operating power**||| ||● at AC-3 at 400 V rated value|15 kW|| ||● at AC-43||| ||— at 400 V rated value|15 000 W|| ||— at 500 V rated value|11 000 W|| ||— at 690 V rated value|11 000 W|| ||**no-load switching frequency**|3 600 1/h|| ||**operating frequency**||| ||● at AC-41 accordingto IEC 60947-6-2 maximum|750 1/h|| ||● at AC-43 accordingto IEC 60947-6-2 maximum|250 1/h|| ||**Control circuit/ Control**||| ||**type of voltage**|AC/DC|| ||**control supply voltage 1 at AC**||| ||● at 50 Hz rated value|24 V|| ||● at 50 Hz|24 V|| ||● at 60 Hz rated value|24 V|| ||● at 60 Hz|24 V|| ||**control supply voltage frequency**||| ||**● 1 rated value**|50 Hz|| ||**● 2 rated value**|60 Hz|| ||**control supply voltage 1 at DC rated value**|24 V|| ||**control supply voltage 1 at DC**|24 V|| ||**holding power**||| ||● at AC maximum|3.5 W|| ||● at DC maximum|3.1 W|| ||**Auxiliary circuit**||| ||**number of NC contacts for auxiliary contacts**|1|| ||**number of NO contacts for auxiliary contacts**|1|| ||number of NO contacts of instantaneous short-circuit trip unit for<br>signalingcontact|1|| ||number of CO contacts of the current-dependent overload<br>release for signalingcontact|1|| ||**operational current of auxiliary contacts at AC-12 maximum**|10 A|| ||operational current of auxiliarycontacts at DC-13 at 250 V|0.27 A|| ||**Protective and monitoring functions**||| ||**trip class**|CLASS 10 and 20 adjustable|| ||3RA61200EB30<br>Page 2/7<br>5/30/2026<br>Subject to change without notice<br>© Copyright Siemens||| ||**operating short-circuit current breaking capacity (Ics)**||| |---|---|---|---| ||● at 400 V rated value|53 kA|| ||● at 500 V rated value|1 kA|| ||● at 690 V rated value|1 kA|| ||**UL/CSA ratings**||| ||**full-load current(FLA) for 3-phase AC motor**||| ||● at 480 V rated value|32 A|| ||yielded mechanicalperformance[hp]for 3-phase AC motor||| ||● at 200/208 V rated value|7.5 hp|| ||● at 220/230 V rated value|10 hp|| ||● at 460/480 V rated value|20 hp|| ||**contact rating of auxiliary contacts according to UL**|contacts 21-22, 13-14, 43-44 Q600 / A600, contacts 77-78 R300 / B300,<br>contacts 95-96-98 R300 / D300|| ||**Short-circuit protection**||| ||**product function short circuitprotection**|Yes|| ||**design of short-circuitprotection**|electromagnetic|| ||**design of the fuse link**||| ||● for short-circuitprotection of the auxiliaryswitch required|fusegL/gG: 10 A|| ||● for short-circuit protection of the signaling switch of the<br>short-circuit release required|6A gL/gG/400V|| ||● for short-circuit protection of the signaling switch of the<br>overload release required|4A gL/gG/400V|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|any|| ||**mounting position recommended**|vertical, on horizontal standard DIN rail|| ||**fastening method**|screw and snap-on mounting|| ||**height**|170 mm|| ||**width**|45 mm|| ||**depth**|165 mm|| ||**Connections/ Terminals**||| ||**product component removable terminal for main circuit**|Yes|| ||**product component removable terminal for auxiliary and**<br>**control circuit**|Yes|| ||**type of electrical connection**||| ||● for main current circuit|plug-in without terminals|| ||● for auxiliaryand control circuit|plug-in without terminals|| ||**Safety related data**||| ||**proportion of dangerous failures**||| ||● with low demand rate accordingto SN 31920|40 %|| ||● with high demand rate accordingto SN 31920|50 %|| ||**B10 value with high demand rate according to SN 31920**|2 000 000|| ||**failure rate [FIT] with low demand rate according to SN**<br>**31920**|100 FIT|| ||IEC 61508||| ||T1 value for proof test interval or service life according to IEC<br>61508|20 a|| ||Electrical Safety||| ||**protection class IP on the front according to IEC 60529**|IP20|| ||**touch protection on the front according to IEC 60529**|finger-safe|| ||**Communication/ Protocol**||| ||**product function bus communication**|No|| ||**protocol is supported**||| ||● AS-Interfaceprotocol|No|| ||● IO-Linkprotocol|No|| ||product function control circuit interface with IO link|No|| ||**Electromagnetic compatibility**||| ||**conducted interference**||| ||● due to burst accordingto IEC 61000-4-4|4 kV main contacts, 2 kV auxiliarycontacts|| ||● due to conductor-earth surge accordingto IEC 61000-4-5|4 kV main contacts, 2 kV auxiliarycontacts|| ||● due to conductor-conductor surge according to IEC<br>61000-4-5|2 kV main contacts, 1 kV auxiliary contacts|| Subject to change without notice © Copyright Siemens 3RA61200EB30 Page 3/7 5/30/2026 ● due to high-frequency radiation according to IEC 610000.15-80Mhz at 10V 4-6 **field-based interference according to IEC 61000-4-3** 10 V/m **electrostatic discharge according to IEC 61000-4-2** 8 kV **conducted HF interference emissions according to** 150 kHz ... 30 MHz Class A **CISPR11** ~~re~~ **field-bound HF interference emission according to CISPR11** 30 ... 1000 MHz Class A **Supply voltage Supply voltage required Auxiliary voltage** No ~~et~~ **Display number of LEDs** 2 ~~ee~~ **Approvals Certificates Environment General Product Approval** Environmental Confirmations ~~—~~ Qu EAL =Cé **General Product ApEMV Functional Saftey Test Certificates Maritime application other proval** Type Examination CerType Test CertificConfirmation tificate ates/Test Report caUK & ~~——_ =~~ a ~~——~~ **other Dangerous goods** Confirmation ~~_ a~~ Transport Information QC PASS ~~e~~ **Further information** ~~e~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RA6120-0EB30 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RA6120-0EB30 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RA6120-0EB30&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RA6120-0EB30 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> Subject to change without notice © Copyright Siemens 3RA61200EB30 Page 4/7 5/30/2026 **==> picture [511 x 360] intentionally omitted <==** Subject to change without notice © Copyright Siemens 3RA61200EB30 Page 5/7 5/30/2026 Subject to change without notice © Copyright Siemens 3RA61200EB30 Page 6/7 5/30/2026 **last modified:** **==> picture [350 x 365] intentionally omitted <==** **----- Start of picture text -----**<br> 33 43<br>1L1 3L2 5L3<br>96 98<br>34 44<br>95<br>13 21 31 41<br>el<br>14 22 32 42<br>I>> I>> I>><br>77<br>31 43<br>A th ri i e L b<br>78 A1 A2<br>32 44<br>2T1 4T2 6T3<br>4/4/2026<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3RA61200EB30 Page 7/7 5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 420,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →