Image not available
Illustrative purposes only
3RA2210-0CH15-2BB4
Load Feeder, Fuseless, Reversing, 3RA2 Series, Three Phase, 0.18 A to 25 A, 24 VDC, Spring Terminal
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 214.27 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RA2210-0CH15-2BB4** **Data sheet** Load feeder fuseless, Reversing duty 400 V AC, Size S00 0.18...0.25 A 24 V DC Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor) ||Load feeder fuseless, Reversing duty 400 V AC, Size S00 0.18...0.25 A 24 V DC<br>Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1)<br>Type of coordination 2, Iq = 150 kA 1 NC (contactor)| |---|---| |**product brand name**|SIRIUS| |**product designation**|Reversingstarter| |**design of theproduct**|for 60 mm busbars| |**product type designation**|3RA22| |**manufacturer's article number**|| |● of the supplied contactor|3RT2015-2BB42| |● of the supplied circuit-breakers<br>~~ee~~|3RV2011-0CA20<br>~~ee~~| |● of the supplied RS assemblykit<br>~~ee~~|3RA2913-1DB2<br>~~ee~~| |● of the supplied link module<br>~~ee~~|3RA2911-2AA00<br>~~ee~~| |**General technical data**<br>~~ee~~|| |**size of the circuit-breaker**<br>~~ee~~|S00<br>~~ee~~| |**size of load feeder**|S00| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstateperpole|2 W| |● without load current share typical|4 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**degree ofprotection NEMA rating**|other| |**shock resistance according to IEC 60068-2-27**|6g/ 11 ms| |mechanical service life(operatingcycles)of contactor typical|30 000 000| |**type of coordination**|2| |**reference code according to IEC 81346-2:2019**|Q| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|1.895 kg| |**Ambient conditions**<br>~~|~~|| |**ambient temperature**<br>~~|~~|~~|~~| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**<br>~~|~~|| |**number ofpoles for main current circuit**<br>~~|~~|3<br>~~|~~| |**design of the switching contact**|electromechanical| |**adjustable current response value current of the current-**<br>**dependent overload release**|0.18 ... 0.25 A| |**operating voltage**|| |● rated value|690 V| |● at AC-3 rated value maximum|690 V| |● at AC-3e rated value maximum|690 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current**|| |● at AC-3 at 400 V rated value|0.3 A| |● at AC-3e at 400 V rated value|0.25 A| |**operating power**|| |● at AC-3|| |— at 400 V rated value|60 W| 3RA22100CH152BB4 Page 1/3 Subject to change without notice © Copyright Siemens 5/30/2026 |● at AC-3e|● at AC-3e||| |---|---|---|---| |— at 400 V rated value||60 W|| |**Control circuit/ Control**|||| |**type of voltage of the control supply voltage**||DC|| |**control supply voltage at DC rated value**||24 V|| |**holding power of magnet coil at DC**||4 W|| |**Auxiliary circuit**|||| |**product extension auxiliary switch**||Yes|| |**Protective and monitoring functions**|||| |**trip class**||CLASS 10|| |**design of the overload release**||thermal(bimetallic)|| |response value current of instantaneous short-circuit trip unit||3.3 A|| |**UL/CSA ratings**|||| |**full-load current(FLA) for 3-phase AC motor**|||| |● at 480 V rated value||0.3 A|| |● at 600 V rated value||0.3 A|| |**Short-circuit protection**|||| |**product function short circuitprotection**||Yes|| |**design of the short-circuit trip**||magnetic|| |**conditional short-circuit current(Iq)**|||| |● at 400 V accordingto IEC 60947-4-1 rated value||150 000 A|| |**Installation/ mounting/ dimensions**|||| |**mounting position**||vertical|| |**fastening method**||for snappingonto 60 mm busbar systems|| |**height**||260 mm|| |**width**||90 mm|| |**depth**||155 mm|| |**required spacing**|||| |● forgroundedparts|||| |— forwards||32 mm|| |— backwards||0 mm|| |— upwards||50 mm|| |— at the side||10 mm|| |— downwards||10 mm|| |● for liveparts|||| |— forwards||32 mm|| |— backwards||0 mm|| |— upwards||50 mm|| |— downwards||10 mm|| |— at the side||10 mm|| |**Connections/ Terminals**|||| |**type of electrical connection**|||| |● for main current circuit||spring-loaded terminals|| |● for auxiliaryand control circuit||spring-loaded terminals|| |**Safety related data**|||| |product function suitable for safetyfunction||Yes|| |Electrical Safety|||| |**touch protection on the front according to IEC 60529**||finger-safe, for vertical contact from the front|| |**Communication/ Protocol**|||| |**protocol is supported**|||| |● PROFINET IOprotocol||No|| |● PROFIsafeprotocol||No|| |protocol is supported AS-Interface protocol||No|| |**Approvals Certificates**|||| |**Environment**|**General Product Approval**||**For use in hazard-**<br>**ous locations**| 3RA22100CH152BB4 Page 2/3 Subject to change without notice © Copyright Siemens 5/30/2026 **==> picture [510 x 529] intentionally omitted <==** **----- Start of picture text -----**<br> Environmental Con-<br>firmations<br>— @ HM << KE ©<br>Test Certificates Maritime application<br>- -<br>Type Test Certific Special Test Certific<br>ates/Test Report ate<br>Maritime application other<br>® a Confirmation Confirmation<br>Railway Dangerous goods<br>-<br>Special Test Certific Transport Information<br>ate<br>e Further information e<br>Information on the packaging<br>https://support.industry.siemens.com/cs/ww/en/view/109813875<br>Information for data generation and storage<br>https://support.industry.siemens.com/cs/ww/en/view/109995012<br>Information- and Downloadcenter (Catalogs, Brochures,…)<br>https://www.siemens.com/ic10<br>Industry Mall (Online ordering system)<br>https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RA2210-0CH15-2BB4<br>Service&Support (Manuals, Certificates, Characteristics, FAQs,...)<br>https://support.industry.siemens.com/cs/ww/en/ps/3RA2210-0CH15-2BB4<br>Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)<br>https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RA2210-0CH15-2BB4&lang=en<br>Cax online generator<br>https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RA2210-0CH15-2BB4<br>Characteristic curves<br>https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no><br>OO last modified: 4/24/2026<br>**----- End of picture text -----**<br> 3RA22100CH152BB4 Page 3/3 Subject to change without notice © Copyright Siemens 5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →