Solid State Relay, SPST-NO, 6 A, 26.4 VDC, DIN Rail, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type:
- Contact Configuration:SPST-NO; Load Current:6A; Operating Voltage Max:26.4VDC; Relay Mounting:DIN Rail; Relay Terminals:Screw; Switching Mode:-; Operating Voltage Min:19.2VDC; Cont
- SVHC: No SVHC (25-Jun-2025)
- Load Current: 6A
- Product Range: 39 Series
- Relay Mounting: DIN Rail
- Switching Mode: -
- Relay Terminals: Screw
- Control Voltage Max: 33VDC
- Control Voltage Min: 1.5VDC
- Contact Configuration: SPST-NO
- Operating Voltage Max: 26.4VDC
- Operating Voltage Min: 19.2VDC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 30.84 € |
| Current stock | 10+ |
| Lead time | 30 days |
**39 SЕRIES**
_Master_ _**INTERFACE**_ - Relay interface modules 0.1 - 2 - 6 A
Packaging machines Bottling plant
Traffic light controls Carousel warehouses Control panels
Panels for electrical distribution
Labelling machines Hoists and cranes
FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
**39 SERIES**
**B**
## **Common features**
- Space saving 6.2 mm wide
- Connections for 16-way jumper link
- Integral coil indication and protection circuit
- Secure retention and easy ejection by plastic clip
- Dual screw head (blade+cross) terminals and Push-in terminals versions
**==> picture [266 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
EMR SSR<br>Electromechanical Relays Solid State Relays<br>**----- End of picture text -----**<br>
- 1 solid state output (options **0.1 A/48 V DC, 6 A/24 V DC, 2 A/240 V AC** )
- **1 CO 6 A/250 V AC**
- High switching capability
- Silent, high speed switching, long electrical life
- 35 mm rail mounting (EN 60715)
## _Master_ _**BASIC**_
- For general use in any type of system
- **EMR: 6 to 24 and 125 V AC/DC,**
- **230 V AC upply**
- **SSR: 6 to 24 V DC, 125 V AC/DC, 230 V AC supply**
- Screw terminal and Push-in terminal
## _Master_ _**BASIC**_ **- EMR ATEX**
- Available on request - See page 16
## _Master_ _**PLUS**_
- Accepts the output fuse module, for the easy and space efficient protection of output circuits
- **EMR: 6 to 125 V AC/DC, 125 and 220 V DC, 230 V AC and 24…240 V AC/DC supply**
- **SSR: 24 - 125 V AC/DC, 6 to 220 V DC, 230 V AC and 24…240 V AC/DC supply**
• **Special 125 V AC/DC and 230 V AC leakage current suppression types (39.31.3, 39.61.3 EMR and 39.30.3, 39.60.3 SSR)**
- Screw terminal and Push-in terminal
## _Master_ _**INPUT**_
- Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices
- **EMR: 6 to 24 V and 125 V AC/DC, 230 V AC supply**
- **SSR: 6 - 24 V DC, 24 - 125 V AC/DC, 230 V AC supply**
- Screw terminal and Push-in terminal
## _Master_ _**OUTPUT**_
- Jumper link option for the quick and easy distribution of supply voltage to output side and its connection to electromagnetic valves and similar output devices
- **EMR: 6 to 24 V and 125 V AC/DC, 230 V AC supply**
- **SSR: 6 to 24 V DC, 125 V AC/DC, 230 V AC supply**
- Screw terminal and Push-in terminal
## _Master_ _**TIMER**_
- Timer adjustment via top mounted rotary knob accessible after assembly
- Control signal terminal
- DIP-switch for selection of 4 time scales and 8 functions
- Output with fuse module option
- **EMR and SSR: 12 to 24 V AC/DC supply**
- Screw terminal and Push-in terminal
**==> picture [315 x 646] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.11/39.01 39.10/39.00<br>é | ; |<br>,<br>nets = Ones 4<br>w careelet<br>ee zs<br>lh<br>ye oo &<br>Oe<br>Page 6 Page 7<br>39.31 - 39.31.3/39.61 - 39.61.3 39.30 - 39.30.3/39.60 - 39.60.3<br>s<br>omit 3 ound:<br>Be: 8-<br>- [ae]<br>erase 2<br>Ane 4<br>i<br>Page 8 Page 9<br>39.41/39.71 39.40/39.70<br>:<br>é ‘<br>f nN<br>E Ques — - Onan : ew<br>|e a acon— eee<br>>» ae<br>1 a esee ws eae wie<br>len" ee | ew & < yn 9 : ; we © 2<br>Seer<br>Page 10 Page 11<br>39.21/39.51 39.20/39.50<br>. |<br>ent Ee<br>“Be<br>: J [eas]<br>fee (" “ain ge<br>ye SE<br>Page 12 Page 13<br>39.81/ 39.91 39.80/39.90<br>. m4 ; a a (x)~<br>i A “a ' L<br>— @nndee | 4- Lg— 278 4<br>pus i ee 3 er<br>vt eee ee i vs roe a Ga 2 Dre<br>|<br>BREa, Gae er y<br>) 7 CE Boayai 40ee<br>caeZi ZeeBoe“ oa4 geevaloFsa Seize,a.Easi alsee= “Teeor éar4 . Jee cA-.2S ae<br>est are eet -iepeeei.<br>Page 14 Page 15<br>**----- End of picture text -----**<br>
**39 SERIES**
**B**
## _Master_ _**BASIC**_
## **39.11 - 39.10 - 39.01 - 39.00**
- For general interface use in any type of system and application.
- Can be used for input interface applications between auxiliary contacts, sensors etc. and controllers, PLC's or motors. Or for output interface between PLC's controllers and relays, solenoids etc.
## _Master_ _**PLUS**_
## **39.31 - 39.30 - 39.31.3 - 39.30.3 - 39.61 - 39.60 - 39.61.3 - 39.60.3**
- This special version provides extra protection for the output circuit thanks to the replaceable fuse module.
- For general interface use in any type of system and application.
- Can be used for input interface applications between auxiliary contacts, sensors etc. and controllers, PLC's or motors. Or for output interface between PLC’s controllers and relays, solenoids etc.
**==> picture [509 x 144] intentionally omitted <==**
**----- Start of picture text -----**<br>
eee Output devices Output devices<br>ak ak<br>e 4/2 a aa<br>eS) ©<br>al el<br>SAF 4<br>Fuse module<br>093.63<br>093.63.0.024<br>093.63.8.230<br>**----- End of picture text -----**<br>
**==> picture [510 x 343] intentionally omitted <==**
**----- Start of picture text -----**<br>
Se PLC - Output oe PLC - Output<br>PLC - Input PLC - Input<br>+) +<br>Fuse module<br>loool 11(13) [ood 11(13)<br>093.63<br>093.63.0.024<br>093.63.8.230<br>IOLOJOLO lOLOTOTO<br>®<br>® | ;° iil e°<br>SZ bo ° 3) Ze °<br>ofall ° ofall °<br>YY) ° YY) °<br>LEeee Input devices Se Input devices<br>**----- End of picture text -----**<br>
**==> picture [6 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
III-2019, www.findernet.com<br>**----- End of picture text -----**<br>
**4**
**39 SERIES**
**B**
## _Master_ _**INPUT**_
## **39.41 - 39.40 - 39.71 - 39.70**
- These models allow the full termination of input device to the interface without the need for additional terminals - saving component cost, time and panel space.
- Quick and easy distribution of supply voltage through the jumper link on the Bus-Bar (BB) connection.
- Ideal for interface applications between the auxiliary contacts, sensors, limit switches and Controllers or PLC’s.
## _Master_ _**OUTPUT**_
## **39.21 - 39.20 - 39.51 - 39.50**
- These models allow the full termination
- of output device to the interface without the need for additional terminals - saving component cost, time and panel space.
- Quick and easy distribution of supply voltage through the jumper link on the Bus-Bar (BB) connection.
- Ideal for interface applications between the PLC’s or Controllers and output devices such as electomagnetic valves or motors etc..
## _Master_ _**TIMER**_
## **39.81 - 39.80 - 39.91 - 39.90**
- Slim and Multifunction Timed Interface modules.
**==> picture [519 x 613] intentionally omitted <==**
**----- Start of picture text -----**<br>
SS Output devices Output devices<br>oA<br>| Bol<br>— ee 11(13) + o e 15<br>Fuse module<br>093.63<br>093.63.0.024<br>093.63.8.230<br>Hii Hii<br>Maia Al egeaeaea Al<br>a A2 I mT A2 l<br>abadid Bl<br>II q ll<br>S PLC - Output — PLC - Output<br>mari mari : i iwuar<br>AU A) AU<br>+h) PLC - Input © PLC - Input<br>|<br>11(13) Pttt 15<br>piulou 12 tas| 16<br>Hi il<br>eprre irre<br>oon 5 o — fil<br>e<br>ia Lick<br>e<br>o Sal e<br>1)<br>ee Input devices LT Input devices<br>III-2019, www.findernet.com<br>**----- End of picture text -----**<br>
**5**
**39 SERIES**
## _Master_ _**BASIC**_ **- EMR**
**==> picture [53 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.11/39.01<br>**----- End of picture text -----**<br>
## **1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems**
- Common connection possible with optional jumper links (terminals A1, A2 and 11)
- UL Listing (certain relay/socket combinations)
**B**
- 6 A electromechanical relay
- 6 to 24 and 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
**==> picture [133 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.11 39.01<br>Screw terminal Push-in terminal<br>**----- End of picture text -----**<br>
For outline drawing see page 25, 26
|**Contact specification**<br>Contact configuration||1 CO (SPDT)|
|---|---|---|
|Rated current/<br>Maximumpeak current|A|6/10|
|Rated voltage/<br>Maximum switchingvoltage|V AC|250/400|
|Rated load AC1|VA|1500|
|Rated load AC15 (230 V AC)|VA|300|
|Singlephase motor rating(230 V AC)<br>kW||0.185|
|BreakingcapacityDC1: 30/110/220 V<br>A||6/0.2/0.12|
|Minimum switchingload|mW (V/mA)|500 (12/10)|
|Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)|V AC/DC|AgNi<br>6 - 12 - 24 - 110…125|
||V AC (50/60 Hz)|220…240|
|Ratedpower|VA (50 Hz)/W|Seepage 20|
|Operatingrange||(0.8…1.1)UN|
|Holdingvoltage||0.6 UN|
|Must drop-out voltage<br>**Technical data**||0.1 UN|
|Mechanical life AC/DC|cycles|10 · 106|
|Electrical life at rated load AC1|cycles|60 · 103|
|Operate/release time|ms|5/6|
|Insulation between coil|||
|and contacts(1.2/50μs)|kV|6(8 mm)|
|Dielectric strength|||
|between open contacts|V AC|1000|
|Ambient temperature range|°C|–40…+70|
|Protection category||IP 20<br>~~a~~|
|**Approvals relay**(according to type)||C€@FALRINAcCAYs|
**6**
**39 SERIES**
**B**
## _Master_ _**BASIC**_ **- SSR**
**==> picture [54 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.10/39.00<br>**----- End of picture text -----**<br>
## **1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems**
- Common connection possible with optional jumper links (terminals A1, A2 and 13+)
- UL Listing (certain relay/socket combinations)
- 0.1, 2 or 6 A solid state relay
- 6 to 24 and 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
**==> picture [134 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.10 39.00<br>Screw terminal Push-in terminal<br>**----- End of picture text -----**<br>
|For outline drawing see page 25, 26|For outline drawing see page 25, 26||||
|---|---|---|---|---|
|**Output specification (SSR)**||**39.x0.x.xxx.9024 **|**39.x0.x.xxx.7048 **|**39.x0.x.xxx.8240**|
|Contact configuration|||1 NO (SPST-NO)||
|Rated current/<br>Maximumpeak current(10 ms)|A|6/50|0.1/0.5|2/80|
|Rated voltage/<br>Maximum blockingvoltage|V|24/33 DC|48/53 DC|240/— AC|
|Switchingvoltage range|V|(1.5…33) DC|(1.5…53) DC|(12…275) AC|
|Repetitivepeak off-state voltage|Vpk|—|—|800|
|Minimum switchingcurrent|mA|1|0.05|35|
|Max. “OFF-state” leakage current|mA|0.001|0.001|1.5|
|Max. “ON-state” voltage drop|V|0.4|1|1.6|
|**Supply specification**<br>Nominal voltage (UN)|V AC/DC||110…125||
||V AC (50/60 Hz)||220…240||
||V DC||6 - 12 - 24||
|Ratedpower|VA (50 Hz)/W||Seepage 21||
|Operatingrange|||(0.8…1.1)UN||
|Must drop-out voltage<br>**Technical data**|||0.1 UN||
|Operate/release time|ms|0.2/0.6|0.04/0.6|12/12|
|Dielectric strength|||||
|between input/output|V AC||3000||
|Ambient temperature range|°C||–20…+55||
|Protection category|||IP 20||
|**Approvals relay**(according to type)||Cé€|®<br>Cé€EALAXts|AXts|
**7**
**39 SERIES**
## _Master_ _**PLUS**_ **- EMR**
## **39.31/39.61**
**==> picture [71 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.31.3/39.61.3<br>**----- End of picture text -----**<br>
## **1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems**
- Accepts output fuse module **093.63, 093.63.0.024, 093.63.8.230** (for 5 x 20 mm fuses) for quick and easy load protection, see page 30
**B**
- Common connection possible with optional jumper links (terminals A1, A2 and 11)
- UL Listing (certain relay/socket combinations)
- 6 A electromechanical relay
- 6 to 125 V AC/DC, 125 and 220 V DC, 230 V AC, 24…240 V AC/DC supply
- Screw terminal and push-in terminal
- 6 A electromechanical relay
- Leakage current suppression version, 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
39.31/39.31.3 39.61/39.61.3 Screw terminal Push-in terminal
**==> picture [40 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse module<br>093.63<br>093.63.0.024<br>093.63.8.230<br>**----- End of picture text -----**<br>
**==> picture [39 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse module<br>093.63<br>093.63.0.024<br>093.63.8.230<br>**----- End of picture text -----**<br>
|For outline drawing see page 25, 26|For outline drawing see page 25, 26|||||||
|---|---|---|---|---|---|---|---|
|**Contact specification**<br>Contact configuration||1 CO (SPDT)||1 CO (SPDT)||1 CO (SPDT)||
|Rated current/<br>Maximumpeak current|A|6/10|||6/10|||
|Rated voltage/<br>Maximum switchingvoltage|V AC|250/400||250/400||||
|Rated load AC1|VA|1500|||1500|||
|Rated load AC15 (230 V AC)|VA|300|||300|||
|Singlephase motor rating(230 V AC)<br>kW||0.185|||0.185|||
|BreakingcapacityDC1: 30/110/220 V<br>A||6/0.2/0.12||6/0.2/0.12||||
|Minimum switchingload|mW (V/mA)|500 (12/10)||500 (12/10)||||
|Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)|V AC/DC|AgNi<br>6 - 12 - 24 - 60 - 110…125 - 24…240||AgNi<br>110…125||||
||V AC (50/60 Hz)|220…240||220…240||||
||V DC|110…125 - 220|||—|||
|Ratedpower|VA (50 Hz)/W|Seepage 20||Seepage 20|||e 20|
|Operatingrange||(0.8…1.1)UN||(0.8…1.1)UN||||
|Holdingvoltage||0.6 UN|||0.6 UN|||
|Must drop-out voltage<br>**Technical data**||0.1 UN|||0.3 UN|||
|Mechanical life AC/DC|cycles|10 · 106||10 · 10||10 · 106||
|Electrical life at rated load AC1|cycles|60 · 103||60 · 10||60 · 103||
|Operate/release time|ms|5/6|||5/6|||
|Insulation between coil||||||||
|and contacts(1.2/50μs)<br>kV<br>Dielectric strength<br>between open contacts<br>V AC<br>Ambient temperature range<br>°C<br>Protection category<br>**Approvals relay**(according to type)||6(8 mm)<br>1000<br>–40…+70 (+55 for 220 V DC)<br>IP 20<br>C€@FALRINA|RINAcANs|6(8 mm)<br>1000<br>–40…+70<br>IP 20||||
**8**
**39 SERIES**
**B**
## _Master_ _**PLUS**_ **- SSR**
## **39.30/39.60**
## **39.30.3/39.60.3**
## **1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems**
- Accepts output fuse module **093.63, 093.63.0.024, 093.63.8.230** (for 5 x 20 mm fuses) for quick and easy load protection, see page 30
- Common connection possible with optional jumper links (terminals A1, A2 and 13+)
- UL Listing (certain relay/socket combinations)
- 0.1, 2 or 6 A solid state relay
- 24 - 125 V AC/DC, 6 to 220 V DC and 230 V AC, 24…240 V AC/DC supply
- Screw terminal and push-in terminal
- 0.1, 2 or 6 A solid state relay
- Leakage current suppression version, 125 V AC DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
**==> picture [134 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.30/39.30.3 39.60/39.60.3<br>Screw terminal Push-in terminal<br>**----- End of picture text -----**<br>
**==> picture [209 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse module : ! : toi ! Fuse module<br>093.63 093.63.0.024 !1! om!ii !pow! iiij iii 093.63 093.63.0.024<br>093.63.8.230 093.63.8.230<br>**----- End of picture text -----**<br>
|For outline drawing see page 25, 26|For outline drawing see page 25, 26||||||||
|---|---|---|---|---|---|---|---|---|
|**Output specification (SSR)**||**39.x0.x.xxx.9024 **|**39.x0.x.xxx.7048 **|**39.x0.x.xxx.8240 **||**39.x0.3.xxx.9024 **|**39.x0.3.xxx.7048 **|**39.x0.3.xxx.8240**|
|Contact configuration|||1 NO (SPST-NO)||||1 NO (SPST-NO)||
|Rated current/<br>Maximumpeak current(10 ms)|A|6/50|0.1/0.5|2/80||6/50|0.1/0.5|2/80|
|Rated voltage/<br>Maximum blockingvoltage|V|24/33 DC|48/53 DC|240/— AC||24/33 DC|48/53 DC|240/— AC|
|Switchingvoltage range|V|(1.5…33) DC|(1.5…53)DC|(12…275) AC||(1.5…33) DC|(1.5…53)DC|(12…275) AC|
|Repetitivepeak off-state voltage|Vpk|—|—|800||—|—|800|
|Minimum switchingcurrent|mA|1|0.05|35||1|0.05|35|
|Max. “OFF-state” leakage current|mA|0.001|0.001|1.5||0.001|0.001|1.5|
|Max. “ON-state” voltage drop|V|0.4|1|1.6||0.4|1|1.6|
|**Supply specification**<br>Nominal voltage (UN)|V AC/DC|24 - 110…125 - 24…240|||||110…125||
||V AC (50/60 Hz)||220…240||||220…240||
||V DC|6 - 12 - 24 - 60 - 110…125 - 220|6 - 12 - 24 - 60 - 110…125 - 220||||—||
|Ratedpower|VA (50 Hz)/W||Seepage 21||||Seepage 21||
|Operatingrange|||(0.8…1.1)UN||||(0.8…1.1)UN||
|Must drop-out voltage<br>**Technical data**|||0.1 UN||||0.3 UN||
|Operate/release time|ms|0.2/0.6|0.04/0.6|12/12||0.2/0.6|0.04/0.6|12/12|
|Dielectric strength|||||||||
|between input/output|V AC||3000||||3000||
|Ambient temperature range|°C||–20…+55||||–20…+55||
|Protection category|||IP 20||||IP 20||
|**Approvals relay**(according to type)||||C€FAL|FAL|®<br>CAXis|||
**9**
**39 SERIES**
## _Master_ _**INPUT**_ **- EMR**
## **39.41/39.71**
## **1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems**
- Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices (Bus-bar connection BB)
- **B** • Gold plated output contact as standard, for better compatibility with low energy PLC inputs
- UL Listing (certain relay/socket combinations)
- 6 A electromechanical relay
- 6 - 12 - 24 - 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
**==> picture [133 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.41 39.71<br>Screw terminal Push-in terminal<br>**----- End of picture text -----**<br>
|For outline drawing see page 25, 26|For outline drawing see page 25, 26||
|---|---|---|
|**Contact specification**<br>Contact configuration||1 CO (SPDT)|
|Rated current/<br>Maximumpeak current|A|6/10|
|Rated voltage/<br>Maximum switchingvoltage|V AC|250/400|
|Rated load AC1|VA|1500|
|Rated load AC15 (230 V AC)|VA|300|
|Singlephase motor rating(230 V AC)<br>kW||0.185|
|BreakingcapacityDC1: 30/110/220 V<br>A||6/0.2/0.12|
|Minimum switchingload|mW (V/mA)|50 (5/2)|
|Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)|V AC/DC|AgNi + Au<br>6 - 12 - 24 - 110…125|
||V AC (50/60 Hz)|220…240|
|Ratedpower|VA (50 Hz)/W|Seepage 20|
|Operatingrange||(0.8…1.1)UN|
|Holdingvoltage||0.6 UN|
|Must drop-out voltage<br>**Technical data**||0.1 UN|
|Mechanical life AC/DC|cycles|10 · 106|
|Electrical life at rated load AC1|cycles|60 · 103|
|Operate/release time|ms|5/6|
|Insulation between coil|||
|and contacts(1.2/50μs)|kV|6(8 mm)|
|Dielectric strength|||
|between open contacts|V AC|1000|
|Ambient temperature range|°C|–40…+70|
|Protection category||IP 20<br>~~ee~~|
|**Approvals relay**(according to type)||C€@EALRINAcANs|
**10**
**39 SERIES**
**B**
## _Master_ _**INPUT**_ **- SSR**
**==> picture [54 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.40/39.70<br>**----- End of picture text -----**<br>
- **1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems**
- Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices (Bus-bar connection BB)
- UL Listing (certain relay/socket combinations)
- 0.1, 2 or 6 A solid state relay
- 6 - 12 - 24 V DC, 24 - 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
**==> picture [134 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.40 39.70<br>Screw terminal Push-in terminal<br>**----- End of picture text -----**<br>
|For outline drawing see page 25, 26|For outline drawing see page 25, 26|||/ 93~~.~~67|
|---|---|---|---|---|
|**Output specification (SSR)**||**39.x0.x.xxx.9024**|**39.x0.x.xxx.7048**|**39.x0.x.xxx.8240**|
|Contact configuration|||1 NO (SPST-NO)||
|Rated current/<br>Maximumpeak current(10 ms)|A|6/50|0.1/0.5|2/80|
|Rated voltage/<br>Maximum blockingvoltage|V|24/33 DC|48/53 DC|240/— AC|
|Switchingvoltage range|V|(1.5…33) DC|(1.5…53) DC|(12…275) AC|
|Repetitivepeak off-state voltage|Vpk|—|—|800|
|Minimum switchingcurrent|mA|1|0.05|35|
|Max. “OFF-state” leakage current|mA|0.001|0.001|1.5|
|Max. “ON-state” voltage drop|V|0.4|1|1.6|
|**Supply specification**<br>Nominal voltage (UN)|V AC/DC||24 - 110…125||
||V AC (50/60 Hz)||220…240||
||V DC||6 - 12 - 24||
|Ratedpower|VA (50 Hz)/W||Seepage 21||
|Operatingrange|||(0.8…1.1)UN||
|Must drop-out voltage<br>**Technical data**|||0.1 UN||
|Operate/release time|ms|0.2/0.6|0.04/0.6|12/12|
|Dielectric strength|||||
|between input/output|V AC||3000||
|Ambient temperature range|°C||–20…+55||
|Protection category<br>**Approvals relay**(according to type)||C€|IP 20<br>®<br>C€FALANus|ANus|
**11**
**39 SERIES**
## _Master_ _**OUTPUT**_ **- EMR**
## **39.21/39.51**
## **1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems**
**B**
- Jumper link option for the quick and easy distribution of supply voltage to output side (Bus-bar connection BB) and its connection to electromagnetic valves and similar output devices
- UL Listing (certain relay/socket combinations)
- 6 A electromechanical relay
- 6 - 12 - 24 - 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
**==> picture [133 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.21 39.51<br>Screw terminal Push-in terminal<br>**----- End of picture text -----**<br>
|For outline drawing see page 25, 26|For outline drawing see page 25, 26||
|---|---|---|
|**Contact specification**<br>Contact configuration||1 NO (SPST-NO)|
|Rated current/<br>Maximumpeak current|A|6/10|
|Rated voltage/<br>Maximum switchingvoltage|V AC|250/400|
|Rated load AC1|VA|1500|
|Rated load AC15 (230 V AC)|VA|300|
|Singlephase motor rating(230 V AC)<br>kW||0.185|
|BreakingcapacityDC1: 30/110/220 V<br>A||6/0.2/0.12|
|Minimum switchingload|mW (V/mA)|500 (12/10)|
|Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)|V AC/DC|AgNi<br>6 - 12 - 24 - 110…125|
||V AC (50/60 Hz)|220…240|
|Ratedpower|VA (50 Hz)/W|Seepage 20|
|Operatingrange||(0.8…1.1)UN|
|Holdingvoltage||0.6 UN|
|Must drop-out voltage<br>**Technical data**||0.1 UN|
|Mechanical life AC/DC|cycles|10 · 106|
|Electrical life at rated load AC1|cycles|60 · 103|
|Operate/release time|ms|5/6|
|Insulation between coil|||
|and contacts(1.2/50μs)|kV|6(8 mm)|
|Dielectric strength|||
|between open contacts|V AC|1000|
|Ambient temperature range|°C|–40…+70|
|Protection category||IP 20<br>~~a~~|
|**Approvals relay**(according to type)||C€@EALRINAcANts|
**12**
**39 SERIES**
**B**
## _Master_ _**OUTPUT**_ **- SSR**
**==> picture [54 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.20/39.50<br>**----- End of picture text -----**<br>
- **1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems**
- Jumper link option for the quick and easy distribution of supply voltage to output side (Bus-bar connection BB) and its connection to electromagnetic valves and similar output devices
- UL Listing (certain relay/socket combinations)
- 0.1, 2 or 6 A solid state relay
- 6 to 24 V DC, 125 V AC/DC and 230 V AC supply
- Screw terminal and push-in terminal • 35 mm rail (EN 60715) mounting
**==> picture [134 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.20 39.50<br>Screw terminal Push-in terminal<br>**----- End of picture text -----**<br>
|For outline drawing see page 25, 26|For outline drawing see page 25, 26||||
|---|---|---|---|---|
|**Output specification (SSR)**||**39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240**|**39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240**|**39.x0.x.xxx.9024 39.x0.x.xxx.7048 39.x0.x.xxx.8240**|
|Contact configuration|||1 NO (SPST-NO)||
|Rated current/<br>Maximumpeak current(10 ms)|A|6/50|0.1/0.5|2/80|
|Rated voltage/<br>Maximum blockingvoltage|V|24/33 DC|48/53 DC|240/— AC|
|Switchingvoltage range|V|(1.5…33) DC|(1.5…53) DC|(12…275) AC|
|Repetitivepeak off-state voltage|Vpk|—|—|800|
|Minimum switchingcurrent|mA|1|0.05|35|
|Max. “OFF-state” leakage current|mA|0.001|0.001|1.5|
|Max. “ON-state” voltage drop|V|0.4|1|1.6|
|**Supply specification**<br>Nominal voltage (UN)|V AC/DC||110…125||
||V AC (50/60 Hz)||220…240||
||V DC||6 - 12 - 24||
|Ratedpower|VA (50 Hz)/W||Seepage 21||
|Operatingrange|||(0.8…1.1)UN||
|Must drop-out voltage<br>**Technical data**|||0.1 UN||
|Operate/release time|ms|0.2/0.6|0.04/0.6|12/12|
|Dielectric strength|||||
|between input/output|V AC||3000||
|Ambient temperature range|°C||–20…+55||
|Protection category|||IP 20||
|**Approvals relay**(according to type)||C€|®<br>C€FALAdis|Adis|
**13**
**39 SERIES**
## _Master_ _**TIMER**_ **- EMR**
**==> picture [54 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.81/39.91<br>**----- End of picture text -----**<br>
**Slim timed interface module, 6.2 mm wide, ideal for space-saving timing solutions in panels**
- Timer adjustment via top mounted rotary knob, accessible after assembly
**B** ,
- Control signal terminal
- DIP-switch for selection of 4 time scales and
- **B** 8 functions
- Accepts output fuse module **093.63, 093.63.0.024, 093.63.8.230** (for 5 x 20 mm
- fuses) for quick and easy load protection, see page 30
- Common connection possible with optional jumper links (terminals A1, A2 and 15)
- UL Listing (certain relay/socket combinations)
• 6 A electromechanical relay
- 12 - 24 V AC/DC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
**AI:** On-delay
39.81 39.91 Screw terminal Push-in terminal
**DI:** Interval
**GI:** Pulse (0.5 s) delayed
**SW:** Symmetrical flasher
(starting pulse on)
**BE:** Off-delay with control signal
**CE:** On- and off-delay with control signal **DE:** Interval with control signal on
Fuse module 093.63 093.63.0.024 093.63.8.230
**EE:** Interval with control signal off
For outline drawing see page 25, 26 **Contact specification**
|Contact configuration|||1 CO (SPDT)|
|---|---|---|---|
|Rated current/<br>Maximumpeak current|A||6/10|
|Rated voltage/<br>Maximum switchingvoltage|V AC||250/400|
|Rated load AC1|VA||1500|
|Rated load AC15 (230 V AC)|VA||300<br>~~Po~~|
|Singlephase motor rating(230 V AC)<br>kW|||0.185|
|BreakingcapacityDC1: 30/110/220 V<br>A|||6/0.2/0.12|
|Minimum switchingload|mW (V/mA)||500 (12/10)<br>~~ee~~|
|Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)<br>Ratedpower AC/DC<br>Operatingrange<br>Holdingvoltage|V AC/DC<br>VA (50 Hz)/W|AgNi<br>12 - 24<br>Seepage 20<br>(0.8…1.1)UN<br>0.6 UN<br>~~popo~~||
|Must drop-out voltage<br>**Technical data**|||0.1 UN|
|Specified time range|||(0.1…3)s, (3…60)s, (1…20)min, (0.3…6)h|
|Repeatability<br>Recoverytime<br>Minimum control impulse<br>Settingaccuracy- full range<br>Electrical life at rated load AC1<br>Ambient temperature range<br>Protection category<br>**Approvals relay**(according to type)|%<br>ms<br>ms<br>%<br>cycles<br>°C|± 1<br>≤ 50<br>50<br>5<br>60 · 103<br>–20…+50<br>IP 20<br>~~popo~~<br>~~pope~~<br>C€@FALRINAcANs||
**14**
**39 SERIES**
**B**
## _Master_ _**TIMER**_ **- SSR**
**==> picture [54 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
39.80/39.90<br>**----- End of picture text -----**<br>
**Slim timed interface module, 6.2 mm wide, ideal for space-saving timing solutions in panels**
- Timer adjustment via top mounted rotary knob; accessible after assembly
- Start terminal
- DIP-switch for selection of 4 time scales and 8 functions
- Accepts output fuse module **093.63, 093.63.0.024, 093.63.8.230** (for 5 x 20 mm fuses) for quick and easy load protection, see page 30
- Common connection possible with optional jumper links (terminals A1, A2 and 15+)
- UL Listing (certain relay/socket combinations)
- 0.1, 2 or 6 A solid state relay
- 12 - 24 V AC/DC supply
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
**AI:** On-delay
39.80 39.90 Screw terminal Push-in terminal
Fuse module 093.63 093.63.0.024 093.63.8.230
**DI:** Interval
**GI:** Pulse (0.5 s) delayed **SW:** Symmetrical flasher (starting pulse on)
**BE:** Off-delay with control signal **CE:** On- and off-delay with control signal **DE:** Interval with control signal on **EE:** Interval with control signal off
|For outline drawing see page 25, 26|||||
|---|---|---|---|---|
|**Output specification (SSR)**||**39.x0.x.xxx.9024**|**39.x0.x.xxx.7048**|**39.x0.x.xxx.8240**|
|Contact configuration|||1 NO (SPST-NO)||
|Rated current/<br>Maximumpeak current(10 ms)|A|6/50|0.1/0.5|2/80|
|Rated voltage/<br>Maximum blockingvoltage|V|24/33 DC|48/53 DC|240/— AC|
|Switchingvoltage range|V|(1.5…33) DC|(1.5…53) DC|(12…275) AC|
|Repetitivepeak off-state voltage|Vpk|—|—|800|
|Minimum switchingcurrent|mA|1|0.05|35|
|Max. “OFF-state” leakage current|mA|0.001|0.001|1.5|
|Max. “ON-state” voltage drop|V|0.4|1|1.6|
|**Supply specification**<br>Nominal voltage (UN)|V AC/DC||12 - 24||
|Ratedpower|VA (50 Hz)/W||Seepage 21||
|Operatingrange|||(0.8…1.1)UN||
|Holdingvoltage|||0.6 UN||
|Must drop-out voltage<br>**Technical data**|||0.1 UN||
|Specified time range||(0.1…3)s, (3…60)s, (1…20)min, (0.3…6)h|||
|Repeatability|%||± 1||
|Recoverytime|ms||≤ 50||
|Minimum control impulse|ms||50||
|Settingaccuracy– full range|%||5||
|Ambient temperature range|°C||–20…+50||
|Protection category<br>**Approvals relay**(according to type)||C€|IP 20<br>C€FALCANs|CANs|
**15**
**39 SERIES**
## _Master_ _**BASIC**_ **- EMR ATEX**
## **39.11/39.01 - x073**
## **1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems**
## **ATEX compliant (EX nA nC)**
- Electromechanical relay
- AC and AC/DC Version
- Screw terminal and Push-in terminal
**B**
- UL Listed
- Cadmium free contacts
- Complies with:
- -EN 60079-0: 2012 and EN 60079-15:2010
- -94/9/CE and 2014/34/UE
- Common connection possible with optional jumper links (terminals A1, A2 and 11) and multipole connector _Master_ _**ADAPTER**_
- 35 mm rail (EN 60715) mounting
- 1 CO 6 A
- Screw terminal and push-in terminal
- 35 mm rail (EN 60715) mounting
- ATEX compliant
39.11 39.01 Screw terminal Push-in terminal
|For outline drawing see page 25, 26|For outline drawing see page 25, 26||
|---|---|---|
|**Contact specification**<br>Contact configuration||1 CO (SPDT)|
|Rated current/<br>Maximumpeak current|A|6/10|
|Rated voltage/<br>Maximum switchingvoltage|V AC|250/400|
|Rated load AC1|VA|1500|
|Rated load AC15 (230 V AC)|VA|300|
|Singlephase motor rating(230 V AC)<br>kW||0.185|
|BreakingcapacityDC1: 30/110/220 V<br>A||6/0.2/0.12|
|Minimum switchingload|mW (V/mA)|500 (12/10)|
|Standard contact material<br>**Coil specification**<br>Nominal voltage (UN)|V AC/DC|AgNi<br>6 - 12 - 24 - 110…125 - 24…240|
||V AC (50/60 Hz)|230…240|
|Ratedpower AC/DC|VA (50 Hz)/W|Seepage 20|
|Operatingrange||(0.8…1.1)UN|
|Holdingvoltage||0.6 UN|
|Must drop-out voltage<br>**Technical data**||0.1 UN|
|Mechanical life AC/DC|cycles|10 · 106|
|Electrical life at rated load AC1|cycles|60 · 103|
|Operate/release time|ms|5/6|
|Insulation between coil|||
|and contacts(1.2/50μs)|kV|6(8 mm)|
|Dielectric strength|||
|between open contacts|V AC|1000|
|Ambient temperature range|°C|–40…+70|
|Protection category||IP 20|
|**Approvals relay**(according to type)||CE&@Mis|
**16**
**39 SERIES**
**B**
## **Ordering information ATEX versions**
Example: 39 series, screw terminals interface module, electromechanical relay output, 1 CO 6 A, 24 V DC, ATEX Version.
**A B C D 3 9 . 1 1 . 7 . 0 2 4 . 0 0 7 3 Series A: Contact material C - D: Option** 0 = AgNi Standard 73 = ATEX **Type** 5 = AgNi + Au Complaiant (Ex nA nC) 0 = Push-in terminals 35 mm rail (EN 60715) mount **B: Contact circuit** 1 = Screw terminals 0 = CO (nPDT) 35 mm rail (EN 60715) mount **No. of poles** 1 = 1 CO, 6 A **Coil version** 0 = AC/DC 7 = DC sensitive 8 = AC (50/60 Hz) **Coil voltage** ~~aT~~ See coil specifications
## **Other data ATEX versions**
**Max current @ 70 °C** Single piece mount > 8 piece mount Type 39.11/01 A 6 5 Type 39.11/01 (110…125)V AC/DC only A 6 4 **Terminals Screw terminals Push-in Terminals** Wire strip length mm 10 8 Screw torque Nm 0.5 — Min. wire size solid and stranded cable solid and stranded cable mm[2] 0.5 0.5 AWG 21 21 Max. wire size solid and stranded cable solid and stranded cable mm[2] 1 x 2.5 1 x 2.5 AWG 1 x 14 1 x 14 **Markings - ATEX versions - ATEX, II 3G Ex nA nC IIC Gc MARKING** Specific marking of explosion protection **II** Component for surface plant (different from mines) **3** Category 3: normal level of protection **G** Explosive atmosphere due to presence of combustible gas vapour or mist **Ex nA** Non-sparking equipment **Ex nC** Sealed device (type of protection for category 3G) **IIC** Gas group **Gc** Equipment Protection Level ~~gg~~ **–40 °C ≤ Ta ≤ +70 °C** Ambient temperature **EPT 15 ATEX 0194 U** EPT: laboratory which issues the CE type certificate 15: year of issue of certificate 0194: number of CE type certificate ~~i,~~ U: ATEX component ~~BS~~ **17**
**39 SERIES**
## **Ordering information**
Example: _Master_ _**PLUS**_ 39 series screw terminal interface module, electromechanical relay output, 1 CO (SPDT), 24 V AC/DC coil.
**B**
**A B C D 0 0 6 0**
## **3 9 . 3 1 . 0 . 0 2 4 . 0 Series**
## **D: Special Version, EMR**
0 = Standard
## **Type**
- 1 = _Master_ _**BASIC**_ , screw terminal
**C: Options, EMR**
- 0 = _Master_ _**BASIC**_ , push-in terminal
6 = Standard
- 3 = _Master_ _**PLUS**_ , screw terminal, fuse-protectable output
## **B: Contact circuit, EMR**
0 = CO (except 39.21/51, 1 NO)
- 6 = _Master_ _**PLUS**_ , push-in terminal, fuse-protectable output
**A: Contact material, EMR**
0 = AgNi Standard
- 4 = _Master_ _**INPUT**_ , screw terminal
- 4 = AgSnO2
- 7 = _Master_ _**INPUT**_ , push-in terminal
- 2 = _Master_ _**OUTPUT**_ , screw terminal
- 5 = AgNi + Au
- 5 = _Master_ _**OUTPUT**_ , push-in terminal
**ABCD: Output version, SSR** 7048 = 0.1 A - 48 V DC
- 8 = _Master_ _**TIMER**_ multifunction, screw terminal, fuse-protectable output
8240 = 2 A - 230 V AC
9024 = 6 A - 24 V DC
- 9 = _Master_ _**TIMER**_ multifunction, push-in terminal, fuse-protectable output
## **No. of poles**
- 1 = 1 CO (only EMR, except 39.21/51, 1 NO)
- 0 = 1 NO (only SSR)
## **Coil version, EMR / Input version, SSR**
- 0 = AC (50/60 Hz)/DC
- 3 = Leakage current suppression AC (50/60 Hz)
- 7 = DC sensitive
- 8 = AC (50/60 Hz)
## **Coil voltage, EMR/Input voltage, SSR**
See page 20
## **EMR - Selecting features and options: only combinations in the same row are possible.**
Preferred selections for best availability are shown in **bold.**
|**Type**|**Coil version**|**A**|**B**|**C**|**D**|
|---|---|---|---|---|---|
|39.11/01|0.006 - 0.012|**0**- 4 - 5|**0**|**6**|**0**|
||**0.024**- 0.125 -**8.230**|||||
|39.31/61|0.006 - 0.012|**0**- 4 - 5|**0**|**6**|**0**|
||**0.024**- 0.060|||||
||0.125 - 0.240 -**8.230**|||||
||7.125 - 7.220|||||
||3.125 - 3.230|||||
|39.41/71|0.006 - 0.012|0 - 4 -**5**|**0**|**6**|**0**|
||**0.024**- 0.125|||||
||**8.230**|||||
|39.21/51|0.006 - 0.012|**0**- 4 - 5|**0**|**6**|**0**|
||**0.024**- 0.125|||||
||**8.230**|||||
|39.81/91|0.012 -**0.024**|**0**|**0**|**6**|**0**|
**SSR - Selecting features and options: only combinations in the same row are possible.**
Preferred selections for best availability are shown in **bold.**
|**Type**|**Input version**|**Output version, ABCD**|
|---|---|---|
|39.10/00|7.006 - 7.012|7048 - 8240 -**9024**|
||**7.024**- 0.125 -**8.230**||
|39.30/60|7.006 - 7.012|7048 - 8240 -**9024**|
||**7.024**- 7.060||
||7.125 - 7.220||
||0.024 - 0.125 - 0.240||
||**8.230**||
||3.125 - 3.230||
|39.40/70|7.006 - 7.012|7048 - 8240 -**9024**|
||**7.024**- 0.024 - 0.125||
||**8.230**||
|39.20/50|7.006 - 7.012|7048 - 8240 -**9024**|
||**7.024**- 0.125||
||**8.230**||
|39.80/90|0.012 -**0.024**|7048 - 8240 -**9024**|
**18**
**39 SERIES**
## **Technical data**
## **Insulation according to EN 61810-1**
|Nominal voltage of supplysystem<br>V AC|Nominal voltage of supplysystem<br>V AC|230/400|230/400|230/400|230/400|
|---|---|---|---|---|---|
|Rated insulation voltage<br>V AC||250||400||
|Pollution degree||3||2||
|**Insulation between coil and contact set**||||||
|Type of Insulation||Reinforced||||
|Overvoltage category||III||||
|Rated impulse voltage<br>kV (1.2/50)μs||6||||
|Dielectric strength<br>V AC||4000||||
|**Insulation between open contacts (EMR)**||||||
|Type of disconnection||Micro-disconnection||||
|Dielectric strength<br>V AC/kV (1.2/50)μs||1000/1.5||||
|||||||
|**Conducted disturbance immunity**||**UN ≤ 60 V**|**UN = 125 V**||**UN = 230 V**|
|Fast transients (burst 5/50 ns, 5 kHz) according to EN 61000-4-4<br>at supplyterminals<br>kV||4|4||4|
|Voltage pulses (surge 1.2/50 μs) according to EN 61000-4-5<br>at supplyterminals(differential mode)<br>kV||0.8|2||4|
|||||||
|**Other data**||||||
|Bounce time (EMR): NO/NC<br>ms||1/6||||
|Vibration resistance (EMR,10…55 Hz): NO/NC<br>g||10/15||||
|Power lost to the environment|without contact current<br>W|0.2 (24 V) - 0.4 (230 V)||||
||with rated current<br>W|0.6 (24 V) - 0.9 (230 V)||||
**B**
|**Terminals**||||
|---|---|---|---|
|||**Screw terminal**|**Push-in terminal**|
|Wire striplength|mm|10|8|
|Screw torque|Nm|0.5|—|
|||**Solid and stranded cable**|**Solid and stranded cable**|
|Min. wire size|mm2|1 x 0.5|1 x 0.5|
||AWG|1 x 21|1 x 21|
|Max. wire size|mm2|1 x 2.5|1 x 2.5|
||AWG|1 x 14|1 x 14|
## **Contact specification (EMR)**
**F 39 - Electrical life (AC) v contact current**
**==> picture [251 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resistive load - cos ϕ = 1<br>Cycles Inductive load - cos ϕ = 0.4<br>**----- End of picture text -----**<br>
## **H 39 - Maximum DC1 breaking capacity**
**==> picture [250 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC voltage (V)<br>DC breaking current (A)<br>**----- End of picture text -----**<br>
- When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 60 · 10[3] can be expected.
- In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased.
**19**
**39 SERIES**
## **Coil specifications - Electromechnical Relay**
**Coil data DC** , type 39.31/61
**B**
|Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Must drop-out<br>voltage<br>Ur|Rated input<br>current at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|---|
|V||V|V|V|mA|W|
|125<br>(110…125)|**7**.125|88|138|12.5|4.6|0.6|
|220|**7**.220|176|242|22|3.0|0.6|
## **Coil data AC/DC** , type 39.11/21/31/41/01/51/61/71
|Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Must drop-out<br>voltage<br>Ur|Rated input<br>current at UN<br>IN|Rated<br>power<br>at UN|(1)60 V AC/DC for type 39.31/61 only<br>(2)24…240 V AC/DC for type 39.31/61 only|
|---|---|---|---|---|---|---|---|
|V||V|V|V|mA|VA/W||
|6|**0**.006|4.8|6.6|0.6|35|0.2/0.2||
|12|**0**.012|9.6|13.2|1.5|15|0.2/0.2||
|24|**0**.024|19.2|26.4|2.4|11|0.25/0.25||
|60(1)|**0**.060|48|66|6.0|5.7|0.35/0.35||
|125<br>(110…125)|**0**.125|88|138|12.5|5.6|0.7/0.7||
|240<br>(24…240)(2)|**0**.240|20.4|264|2.4|19|1.5/0.3||
## **Coil data AC** , type 39.11/21/31/41/01/51/61/71
|Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Must drop-out<br>voltage<br>Ur|Rated input<br>current at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|---|
|V||V|V|V|mA|VA/W|
|230<br>(230…240)|**8**.230|184|264|23|4.3|1/0.4|
## **Coil data leakage current suppression versions** , type 39.31.3/61.3
|Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Must drop-out<br>voltage<br>Ur|Rated input<br>current at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|---|
|V||V|V|V|mA|VA/W|
|125<br>(110…125)|**3**.125|88|138|44|8.4|1.1/1|
|230<br>(230…240)|**3**.230|184|264|72|5.9|1.4/0.5|
The 39 Series interface modules (supply version 3) have built-in leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110…125)V AC/DC and (230…240)V AC.
This problem can occur, for example, when connecting the interface modules to PLC's with triac outputs or when connecting via relatively long cables.
## **Coil data AC/DC timer** , type 39.81/91
|Nominal<br>voltage<br>UN|Coil code|Operating range<br>(AC/DC)<br>Umin<br>Umax|Operating range<br>(AC/DC)<br>Umin<br>Umax|Must drop-out<br>voltage<br>Ur|Rated input current<br>at UN<br>DC<br>AC|Rated input current<br>at UN<br>DC<br>AC|Rated power at UN<br>DC<br>AC|Rated power at UN<br>DC<br>AC|
|---|---|---|---|---|---|---|---|---|
|V||V|V|V|mA|mA|W|VA/W|
|12|**0**.012|9.6|13.2|1.2|15|23|0.2|0.3/0.2|
|24|**0**.024|19.2|26.4|2.4|11|19|0.25|0.4/0.3|
**20**
**39 SERIES**
## **Input specifications - Solid State Relay**
**Input data DC** , type 39.10/20/30/40/00/50/60/70
|Nominal<br>voltage<br>UN|Input<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Must drop-out<br>voltage<br>Ur|Rated input<br>current at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|---|
|V||V|V|V|mA|W|
|6|**7**.006|4.8|6.6|0.6|7.5|0.2|
|12|**7**.012|9.6|13.2|1.2|20.7|0.25|
|24|**7**.024|19.2|26.4|2.4|10.5|0.25|
|60(1)|**7**.060|38|66|6.0|6.4|0.4|
|125(1)<br>(110…125)|**7**.125|88|138|12.5|4.6|0.6|
|220(1)|**7**.220|176|242|22|3.0|0.6|
(1) 60 V DC, 125 V DC and 220 V DC for type 39.30/60 only
**B**
## **Input data AC/DC** , type 39.10/20/30/40/00/50/60/70
|Nominal<br>voltage<br>UN|Input<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Must drop-out<br>voltage<br>Ur|Rated input<br>current at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|---|
|V||V|V|V|mA|VA/W|
|24(2)|**0**.024|19.2|26.4|2.4|17.5|0.4/0.3|
|125<br>(110…125)|**0**.125|88|138|12.5|5.5|0.7/0.7|
|240<br>(24…240)(3)|**0**.240|20.4|264|2.4|17.5|1.5/0.3|
(2) 24 V AC/DC for type 39.30/40/60/70 only (3) 24…240 V AC/DC for type 39.30/60 only
## **Input data AC** , type 39.10/20/30/40/00/50/60/70
|Nominal<br>voltage<br>UN|Input<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Must drop-out<br>voltage<br>Ur|Rated input<br>current at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|---|
|V||V|V|V|mA|VA/W|
|230<br>(230…240)|**8**.230|184|264|23|4.2|1/0.4|
**Input data leakage current suppression versions** , type 39.30.3/60.3
|Nominal<br>voltage<br>UN|Input<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Must drop-out<br>voltage<br>Ur|Rated input<br>current at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|---|
|V||V|V|V|mA|VA/W|
|125<br>(110…125)|**3**.125|88|138|44|8.4|1.1/1|
|230<br>(230…240)|**3**.230|184|264|72|5.9|1.4/0.5|
The 39 Series interface modules (supply version 3) have built-in leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110…125)V AC/DC and (230…240)V AC.
This problem can occur, for example, when connecting the interface modules to PLC's with triac outputs or when connecting via relatively long cables.
## **Input data AC/DC timer** , type 39.80/90
|**Input data**|**AC/DC tim**|**er**, type 39.80/90|**er**, type 39.80/90||||||
|---|---|---|---|---|---|---|---|---|
|Nominal<br>voltage<br>UN|Input<br>code|Operating range<br>(AC/DC)<br>Umin<br>Umax||Must drop-out<br>voltage<br>Ur|Rated input current<br>at UN<br>DC<br>AC||Rated power at UN<br>DC<br>AC||
|V||V|V|V|mA|mA|W|VA/W|
|12|**0**.012|9.6|13.2|1.2|15|23|0.2|0.3/0.2|
|24|**0**.024|19.2|26.4|2.4|11|19|0.25|0.4/0.3|
**21**
**39 SERIES**
## **Output specification - Solid State Relays**
**B**
**L 34-1 - Output DC current v ambient temperature**
39.xx.x.xxx.9024
**==> picture [198 x 126] intentionally omitted <==**
**L 34 - Output AC current v ambient temperature**
39.xx.x.xxx.8240
**==> picture [196 x 126] intentionally omitted <==**
**I:** SSR installed as a group (without gap between sockets)
**II:** SSR installed individually in free air , or with a gap ≥ 9 mm, which implies a not significant influence from nearby components
|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle) at ambient temperature 50°C, single mounting|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle) at ambient temperature 50°C, single mounting|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle) at ambient temperature 50°C, single mounting|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle) at ambient temperature 50°C, single mounting|
|---|---|---|---|
|Load|39.xx.x.xxx.**9024**|39.xx.x.xxx.**8240**|39.xx.x.xxx.**7048**|
|24 V 6 A DC1|180 000|—|—|
|24 V 3 A DC L/R = 10 ms|5000|—|—|
|24 V 2 A DC L/R = 40 ms|3600|—|—|
|24 V 1 A DC L/R = 40 ms|6500|—|—|
|24 V 0.8 A DC L/R = 40 ms|9000|—|—|
|24 V 1.5 A DC L/R = 80 ms|3250|—|—|
|230 V 2 A AC1|—|60 000|—|
|230 V 1.25 A AC15|—|3600|—|
|48 V 0.1 A DC1|—|—|60 000|
**22**
**39 SERIES**
## **Timer specifications**
**==> picture [512 x 166] intentionally omitted <==**
**----- Start of picture text -----**<br>
EMC specifications<br>Type of test Reference standard<br>contact discharge EN 61000-4-2 4 kV<br>Electrostatic discharge<br>air discharge EN 61000-4-2 8 kV<br>(80 ÷ 1000 MHz) EN 61000-4-3 10 V/m<br>Radio-frequency electromagnetic field<br>(1400 ÷ 2700 MHz) EN 61000-4-3 10 V/m<br>on Supply terminals EN 61000-4-4 4 kV<br>Fast transients (burst) (5-50 ns, 5 and 100 kHz)<br>on control signal terminals EN 61000-4-4 4 kV<br>Surges (1.2/50 μs) on supply and control common mode EN 61000-4-5 2 kV<br>signal terminals differential mode EN 61000-4-5 0.8 kV<br>Radio-frequency common mode on Supply terminals EN 61000-4-6 10 V<br>(0.15 ÷ 80 MHz) on control signal terminals EN 61000-4-6 3 V<br>Radiated and conducted emission EN 55022 class B<br>**----- End of picture text -----**<br>
**B**
|**Other data**|||||
|---|---|---|---|---|
|Bounce time (EMR): NO/NC||ms|1/6||
|Vibration resistance (EMR,10...55 Hz): NO/NC||g|10/15||
|Power lost to the environment|without contact current|W|0.3||
||with rated current|W|0.8||
||||||
|**Terminals**|||||
||||**Screw terminal**|**Push-in terminal**|
|Wire striplength<br>||mm <br>|10<br>|8|
|Screw torque||Nm|0.5|—|
||||**Solid and stranded cable**|**Solid and stranded cable**|
|Min. wire size||mm2|1 x 0.5|1 x 0.5|
|||AWG|1 x 21|1 x 21|
|Max. wire size||mm2|1 x 2.5|1 x 2.5|
|||AWG|1 x 14|1 x 14|
## **Times scales**
**1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5** (0.1…3)s (3…60)s (1…20)min (0.3…6)h
## **Functions**
||LED|Supply voltage|NO contact/output|
|---|---|---|---|
|||OFF|Open|
|||ON|Open|
|||ON|Open (timing to close in progress)|
|||ON|Closed|
**23**
**39 SERIES**
**==> picture [540 x 561] intentionally omitted <==**
**----- Start of picture text -----**<br>
Wiring diagram U = Supply voltage S = Signal switch = Output contact<br>Without control signal (AI) On-delay<br>Apply power to timer. Output contacts transfer after<br>preset time has elapsed. Reset occurs when power is<br> 1 2 3 4 5<br>removed.<br>(DI) Interval<br>B Apply power to timer. Output contacts transfer<br> 1 2 3 4 5 immediately. After the preset time has elapsed, contacts<br>reset.<br>(GI) Pulse (0.5 s) delayed<br>Apply power to timer. Output contacts transfer after<br>preset time has elapsed. Reset occurs after a fixed time<br> 1 2 3 4 5<br>of 0.5 s.<br>(SW) Symmetrical flasher (starting pulse on)<br>Apply power to timer. Output contacts transfer<br> 1 2 3 4 5 immediately and cycle between ON and OFF for as long<br>as power is applied. The ratio is 1:1 (time on = time off).<br>With control signal (BE) Off-delay with control signal<br>Power is permenently applied to the timer. The output<br> 1 2 3 4 5 contacts transfer immediately on closure of the Signal<br>Switch (S). Opening the Signal Switch initiates the<br>preset delay, after which time the output contacts reset.<br>*<br>(CE) On- and off-delay with control signal<br>Power is permenently applied to the timer. Closing the<br>* With DC supply, 1 2 3 4 5 Signal Switch (S) initiates the preset delay, after which<br>time the output contacts transfer. Opening the Signal<br>positive polarity has<br>switch initiates the same preset delay, after which time<br>to be conneted to B1,<br>the output contacts reset.<br>terminal (according to<br>EN 60204-1).<br>(DE) Interval with control signal on<br>Power is permenently applied to the timer. On momentary<br> 1 2 3 4 5 or maintained closure of Signal Switch (S), the output<br>contacts transfer, and remain so for the duration of the<br>preset delay, after which they reset.<br>(EE) Interval with control signal off<br>Power is permenently applied to the timer. On opening<br> 1 2 3 4 5 of the Signal Switch (S) the output contacts transfer,<br>and remain so for the duration of the preset delay, after<br>which they reset.<br>**----- End of picture text -----**<br>
- Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1.
**==> picture [67 x 50] intentionally omitted <==**
- ** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 24 V AC
B1 - A2 = 12 V DC
**24**
**39 SERIES**
**B**
## **Outline drawings - Screw terminal sockets**
**==> picture [64 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Types 39.10/39.20<br>39.11/39.21<br>Screw terminal<br>**----- End of picture text -----**<br>
**==> picture [180 x 196] intentionally omitted <==**
**==> picture [64 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
Types 39.40<br>39.41<br>Screw terminal<br>**----- End of picture text -----**<br>
**==> picture [179 x 201] intentionally omitted <==**
**==> picture [173 x 273] intentionally omitted <==**
**----- Start of picture text -----**<br>
Types 39.30/39.30.3<br>39.31/39.31.3<br>Screw terminal<br>Types 39.80<br>39.81<br>Screw terminal<br>**----- End of picture text -----**<br>
**==> picture [184 x 201] intentionally omitted <==**
**25**
**==> picture [52 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
39<br>SERIES<br>**----- End of picture text -----**<br>
**==> picture [232 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
Outline drawings - Push-in terminal sockets<br>**----- End of picture text -----**<br>
**==> picture [29 x 54] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>**----- End of picture text -----**<br>
**==> picture [68 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Types 39.00/39.01<br>39.50/39.51<br>Push-in terminal<br>**----- End of picture text -----**<br>
**==> picture [202 x 201] intentionally omitted <==**
**==> picture [68 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Types 39.60/39.60.3<br>39.61/39.61.3<br>Push-in terminal<br>**----- End of picture text -----**<br>
**==> picture [200 x 207] intentionally omitted <==**
**==> picture [68 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Types 39.70<br>39.71<br>Push-in terminal<br>**----- End of picture text -----**<br>
**==> picture [204 x 211] intentionally omitted <==**
**==> picture [68 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Types 39.90<br>39.91<br>Push-in terminal<br>**----- End of picture text -----**<br>
**==> picture [139 x 209] intentionally omitted <==**
**==> picture [45 x 148] intentionally omitted <==**
## **Main features**
## **Push-in terminals**
The push-in terminals permit the quick connection of solid wires or ferrules by their simple insertion into the terminal ( **A** ). It is possible to open the terminal to extract the wire by first pushing down on the push-button using a screwdriver ( **C** ). For stranded cable it is necessary first to open the terminal using the push button, both for the extraction ( **C** ) and insertion ( **B** ). It is possible at any time to check the connection via the test aperture, using a 2 mm diameter test probe ( **D** ).
**==> picture [442 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B C D<br>**----- End of picture text -----**<br>
**26**
**39 SERIES**
## **Electromechanical Relay (1 Pole 6 A) & Screw Socket Combinations**
Example: .xxxx .9024 .7048 .8240
|**Interface Module Code**|**Coil voltage**|**Relay**|**Socket**||
|---|---|---|---|---|
|_Master_**_BASIC_**|||||
|39.11.0.006.0060|6 V AC/DC|34.51.7.005.0010|93.61.7.024||
|39.11.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.61.7.024||
|39.11.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.61.7.024||
|39.11.0.125.0060|(110…125)V AC/DC|34.51.7.060.0010|93.61.0.125||
|39.11.8.230.0060|(230…240)V AC|34.51.7.060.0010|93.61.8.230||
|_Master_**_PLUS_**||||**B**|
|39.31.0.006.0060|6 V AC/DC|34.51.7.005.0010|93.63.7.024||
|39.31.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.63.7.024||
|39.31.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.63.7.024||
|39.31.0.060.0060|60 V AC/DC|34.51.7.060.0010|93.63.7.060||
|39.31.0.125.0060|(110…125)V AC/DC|34.51.7.060.0010|93.63.0.125||
|39.31.0.240.0060|(24…240)V AC/DC|34.51.7.024.0010|93.63.0.240||
|39.31.8.230.0060|(230…240)V AC|34.51.7.060.0010|93.63.8.230||
|39.31.7.125.0060|(110…125)V DC|34.51.7.060.0010|93.63.7.125||
|39.31.7.220.0060|220 V DC|34.51.7.060.0010|93.63.7.220||
|39.31.3.125.0060|(110…125)V AC/DC|34.51.7.060.0010|93.63.3.125||
|39.31.3.230.0060|(230…240)V AC|34.51.7.060.0010|93.63.3.230||
|_Master_**_INPUT_**|||||
|39.41.0.006.5060|6 V AC/DC|34.51.7.005.5010|93.64.7.024||
|39.41.0.012.5060|12 V AC/DC|34.51.7.012.5010|93.64.7.024||
|39.41.0.024.5060|24 V AC/DC|34.51.7.024.5010|93.64.7.024||
|39.41.0.125.5060|(110…125)V AC/DC|34.51.7.060.5010|93.64.0.125||
|39.41.8.230.5060|(230…240)V AC|34.51.7.060.5010|93.64.8.230||
|_Master_**_OUTPUT_**1 NO, 6 A only|||||
|39.21.0.006.0060|6 V AC/DC|34.51.7.005.0010|93.62.7.024||
|39.21.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.62.7.024||
|39.21.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.62.7.024||
|39.21.0.125.0060|(110…125)V AC/DC|34.51.7.060.0010|93.62.0.125||
|39.21.8.230.0060|(230…240)V AC|34.51.7.060.0010|93.62.8.230||
|_Master_**_TIMER_**|||||
|39.81.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.68.0.024||
|39.81.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.68.0.024||
|**Solid State Relay (1**|**Pole 0.1, 2 or 6 A) &**|**Screw Socket Combinations**|||
|**Interface Module Code**|**Input voltage**|**Relay**|**Socket**||
|_Master_**_BASIC_**|||||
|39.10.7.006.xxxx|6 V DC|34.81.7.005.xxxx|93.61.7.024||
|39.10.7.012.xxxx|12 V DC|34.81.7.012.xxxx|93.61.7.024||
|39.10.7.024.xxxx|24 V DC|34.81.7.024.xxxx|93.61.7.024||
|39.10.0.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.61.0.125||
|39.10.8.230.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.61.8.230||
|_Master_**_PLUS_**|||||
|39.30.7.006.xxxx|6 V DC|34.81.7.005.xxxx|93.63.7.024||
|39.30.7.012.xxxx|12 V DC|34.81.7.012.xxxx|93.63.7.024||
|39.30.7.024.xxxx|24 V DC|34.81.7.024.xxxx|93.63.7.024||
|39.30.7.060.xxxx|60 V DC|34.81.7.060.xxxx|93.63.7.060||
|39.30.7.125.xxxx|(110…125)V DC|34.81.7.060.xxxx|93.63.7.125||
|39.30.7.220.xxxx|220 V DC|34.81.7.060.xxxx|93.63.7.220||
|39.30.0.024.xxxx|24 V AC/DC|34.81.7.024.xxxx|93.63.0.024||
|39.30.0.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.63.0.125||
|39.30.0.240.xxxx|(24…240)V AC/DC|34.81.7.024.xxxx|93.63.0.240||
|39.30.8.230.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.63.8.230||
|39.30.3.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.63.3.125||
|39.30.3.230.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.63.3.230||
|_Master_**_INPUT_**|||||
|39.40.7.006.xxxx|6 V DC|34.81.7.005.xxxx|93.64.7.024||
|39.40.7.012.xxxx|12 V DC|34.81.7.012.xxxx|93.64.7.024||
|39.40.7.024.xxxx|24 V DC|34.81.7.024.xxxx|93.64.7.024||
|39.40.0.024.xxxx|24 V AC/DC|34.81.7.024.xxxx|93.64.0.024||
|39.40.0.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.64.0.125||
|39.40.8.230.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.64.8.230||
|_Master_**_OUTPUT_**|||||
|39.20.7.006.xxxx|6VDC|34.81.7.005.xxxx|93.62.7.024||
|39.20.7.012.xxxx|12 VDC|34.81.7.012.xxxx|93.62.7.024||
|39.20.7.024.xxxx|24 VDC|34.81.7.024.xxxx|93.62.7.024||
|39.20.0.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.62.0.125||
|39.20.8.230.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.62.8.230||
|_Master_**_TIMER_**|||||
|39.80.0.012.xxxx|12 V AC/DC|34.81.7.012.xxxx|93.68.0.024||
|39.80.0.024.xxxx|24 V AC/DC|34.81.7.024.xxxx|93.68.0.024||
**27**
**39 SERIES**
**B**
## **Electromechanical Relay (1 Pole 6 A) & Push-in Socket Combinations**
|Example: .xxxx<br>.9024<br>.7048<br>.8240|**Interface Module Code**|**Coil voltage**|**Relay**|**Socket**|
|---|---|---|---|---|
||_Master_**_BASIC_**||||
||39.01.0.006.0060|6 V AC/DC|34.51.7.005.0010|93.60.7.024|
||39.01.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.60.7.024|
||39.01.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.60.7.024|
||39.01.0.125.0060|(110…125)V AC/DC|34.51.7.060.0010|93.60.0.125|
||39.01.8.230.0060|(230…240)V AC|34.51.7.060.0010|93.60.8.230|
||_Master_**_PLUS_**||||
||39.61.0.006.0060|6 V AC/DC|34.51.7.005.0010|93.66.7.024|
||39.61.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.66.7.024|
||39.61.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.66.7.024|
||39.61.0.060.0060|60 V AC/DC|34.51.7.060.0010|93.66.7.060|
||39.61.0.125.0060|(110…125)V AC/DC|34.51.7.060.0010|93.66.0.125|
||39.61.0.240.0060|(24…240)V AC/DC|34.51.7.024.0010|93.66.0.240|
||39.61.8.230.0060|(230…240)V AC|34.51.7.060.0010|93.66.8.230|
||39.61.7.125.0060|(110…125)V DC|34.51.7.060.0010|93.66.7.125|
||39.61.7.220.0060|220 V DC|34.51.7.060.0010|93.66.7.220|
||39.61.3.125.0060|(110…125)V AC/DC|34.51.7.060.0010|93.66.3.125|
||39.61.3.230.0060|(230…240)V AC|34.51.7.060.0010|93.66.3.230|
||_Master_**_INPUT_**||||
||39.71.0.006.5060|6 V AC/DC|34.51.7.005.5010|93.67.7.024|
||39.71.0.012.5060|12 V AC/DC|34.51.7.012.5010|93.67.7.024|
||39.71.0.024.5060|24 V AC/DC|34.51.7.024.5010|93.67.7.024|
||39.71.0.125.5060|(110…125)V AC/DC|34.51.7.060.5010|93.67.0.125|
||39.71.8.230.5060|(230…240)V AC|34.51.7.060.5010|93.67.8.230|
||_Master_**_OUTPUT_**1 NO, 6 A only||||
||39.51.0.006.0060|6 V AC/DC|34.51.7.005.0010|93.65.7.024|
||39.51.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.65.7.024|
||39.51.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.65.7.024|
||39.51.0.125.0060|(110…125)V AC/DC|34.51.7.060.0010|93.65.0.125|
||39.51.8.230.0060|(230…240)V AC|34.51.7.060.0010|93.65.8.230|
||_Master_**_TIMER_**||||
||39.91.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.69.0.024|
||39.91.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.69.0.024|
||**Solid State Relay (1 Pole 0.1, 2 or 6 A) & Push-in Socket Combinations**||||
||**Interface Module Code**|**Input voltage**|**Relay**|**Socket**|
||_Master_**_BASIC_**||||
||39.00.7.006.xxxx|6 V DC|34.81.7.005.xxxx|93.60.7.024|
||39.00.7.012.xxxx|12 V DC|34.81.7.012.xxxx|93.60.7.024|
||39.00.7.024.xxxx|24 V DC|34.81.7.024.xxxx|93.60.7.024|
||39.00.0.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.60.0.125|
||39.00.8.230.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.60.8.230|
||_Master_**_PLUS_**||||
||39.60.7.006.xxxx|6 V DC|34.81.7.005.xxxx|93.66.7.024|
||39.60.7.012.xxxx|12 V DC|34.81.7.012.xxxx|93.66.7.024|
||39.60.7.024.xxxx|24 V DC|34.81.7.024.xxxx|93.66.7.024|
||39.60.7.060.xxxx|60 V DC|34.81.7.060.xxxx|93.66.7.060|
||39.60.7.125.xxxx|(110…125)V DC|34.81.7.060.xxxx|93.66.7.125|
||39.60.7.220.xxxx|220 V DC|34.81.7.060.xxxx|93.66.7.220|
||39.60.0.024.xxxx|24 V AC/DC|34.81.7.024.xxxx|93.66.0.024|
||39.60.0.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.66.0.125|
||39.60.0.240.xxxx|(24…240)V AC/DC|34.81.7.024.xxxx|93.66.0.240|
||39.60.8.230.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.66.8.230|
||39.60.3.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.66.3.125|
||39.60.3.230.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.66.3.230|
||_Master_**_INPUT_**||||
||39.70.7.006.xxxx|6 V DC|34.81.7.005.xxxx|93.67.7.024|
||39.70.7.012.xxxx|12 V DC|34.81.7.012.xxxx|93.67.7.024|
||39.70.7.024.xxxx|24 V DC|34.81.7.024.xxxx|93.67.7.024|
||39.70.0.024.xxxx|24 V AC/DC|34.81.7.024.xxxx|93.67.0.024|
||39.70.0.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.67.0.125|
||39.70.8.230.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.67.8.230|
||_Master_**_OUTPUT_**||||
||39.50.7.006.xxxx|6VDC|34.81.7.005.xxxx|93.65.7.024|
||39.50.7.012.xxxx|12 VDC|34.81.7.012.xxxx|93.65.7.024|
||39.50.7.024.xxxx|24 VDC|34.81.7.024.xxxx|93.65.7.024|
||39.50.0.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.65.0.125|
||39.50.8.230.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.65.8.230|
||_Master_**_TIMER_**||||
||39.90.0.012.xxxx|12 V AC/DC|34.81.7.012.xxxx|93.69.0.024|
||39.90.0.024.xxxx|24 V AC/DC|34.81.7.024.xxxx|93.69.0.024|
**28**
**39 SERIES**
_Master_ _**BASIC**_ **ATEX version, Screw Socket Combinations**
|_Master_**_BASIC_ ATEX v**|**ersion, Screw Socke**|**t Combinations**||
|---|---|---|---|
|**Interface Module Code**|**Coil voltage**|**Relay**|**Socket**|
|_Master_**_BASIC_ ATEX**||||
|39.11.0.006.0073|6 V AC/DC|34.51.7.005.0000|93.61.0.024.7|
|39.11.0.012.0073|12 V AC/DC|34.51.7.012.0000|93.61.0.024.7|
|39.11.0.024.0073|24 V AC/DC|34.51.7.024.0000|93.61.0.024.7|
|39.11.0.125.0073|(110…125)V AC/DC|34.51.7.060.0000|93.61.0.125.7|
|39.11.0.240.0073|(24…240)V AC/DC|34.51.7.024.0000|93.61.0.240.7|
|39.11.8.230.0073|(230…240)V AC|34.51.7.060.0000|93.61.8.230.7|
**B**
_Master_ _**BASIC**_ **ATEX version, Push-in Socket Combinations**
|_Master_**_BASIC_ ATEX v**|**ersion, Push-in Sock**|**et Combinations**||
|---|---|---|---|
|**Interface Module Code**|**Input voltage**|**Relay**|**Socket**|
|_Master_**_BASIC_ ATEX**||||
|39.01.0.006.0073|6 V AC/DC|34.51.7.005.0000|93.60.0.024.7|
|39.01.0.012.0073|12 V AC/DC|34.51.7.012.0000|93.60.0.024.7|
|39.01.0.024.0073|24 V AC/DC|34.51.7.024.0000|93.60.0.024.7|
|39.01.0.125.0073|(110…125)V AC/DC|34.51.7.060.0000|93.60.0.125.7|
|39.01.0.240.0073|(24…240)V AC/DC|34.51.7.024.0000|93.60.0.240.7|
|39.01.8.230.0073|(230…240)V AC|34.51.7.060.0000|93.60.8.230.7|
**29**
**39 SERIES**
## **Accessories**
**Output fuse module for** 39.31/30/81/80/61/60/91/90 types 093.63 093.63.0.024 093.63.8.230
- For 5 x 20 mm fuses up to 6 A, 250 V
- Type 093.63 - Easy visibility of the fuse condition through the window
- Type 093.63.0.024 - (6…24)V AC/DC with LED fuse status indicator
**B 093.63** Approvals (according to type): ,C€ EAL cCAXus
- Type 093.63.8.230 - (110…240)V AC with LED fuse status indicator
- Quick connection to socket
## **Notes**
**Safety:** Because the output circuit can be reinstated (point 3 below), even with the fuse removed, it is important not to consider the removal of the fuse as a “safety disconnect”. Always isolate elsewhere before working on the circuit. **UL:** According to UL508A, the fuse module cannot be installed in power circuits (in which it is mandatory that a fuse certified according to UL category JDDZ be fitted). However, where the MasterInterface is connected as an output interface to a PLC no such restrictions apply, and the fuse module can be usefully employed.
**Type 093.63.0.24 / 093.63.8.230**
**Type 093.63**
**093.63.0.024 093.63.8.230**
## **Multi-state fuse module**
**0.** As delivered, the socket comes without a fuse module. However, the absent fuse is internally replaced with an electrical link - which allows the interface relay to be used without a fuse module.
In this state, the peg/indicator is visually hidden and the connection is protected by a special cap.
**1.** With fuse module inserted after removing the cap, the fuse is positioned electrically in series with the common output terminal of the interface module (11 for EMR versions, 13+ for SSR versions, 15 for EMR timer, 15+ for SSR timer). This state is indicated by the peg/indicator.
**2.** If the fuse module is extracted (for example; because the fuse element has blown) the output circuit will be locked open, as this will generally be the “safe option”.
- This state is indicated by the peg/indicator.
**3.** In order to reinstate the output circuit it is necessary to either re-insert the fuse module (complete with functional fuse), or alternatively, return the peg/indicator to position **0** by gently applying pressure in the direction of the arrow.
**30**
**39 SERIES**
## **Accessories**
**==> picture [532 x 726] intentionally omitted <==**
**----- Start of picture text -----**<br>
16-way jumper link 093.16 (blue) 093.16.0 (black) 093.16.1 (red)<br>Rated values 6 A - 250 V<br>093.16 Possibility of multiple connection, side by side<br>LEST a: ts<br>093.16.0<br>EEE er ~ bon 6 B<br>093.16.1 JVUUUYUUUUUUUUUUU ~<br>1.25 1.25<br>Approvals<br>(according to type): 4.95 4.95<br>C€ € EAL ANs® 6.2 6.2 6.2 “6.2 6.2<br>| Dual-purpose plastic separator (1.8 mm or 6.2 mm separation) | 093.60<br>1. By breaking off the protruding ribs (by hand), the separator becomes only 1.8 mm thick; useful for the visual separation of<br>different groups of interfaces, or necessary for the protective separation of different voltages of neighbouring interfaces, or<br>LuAb oo for the protection of cut ends of jumper links.<br>093.60 |<br>Ee Ce) Foss fe “od<br>= | pecan = :<br>ae = =e<br>Lf oa Le =<br>2. Leaving the ribs in place provides 6.2 mm separation. Simply cutting (with scissors) the relevant segment(s) permits the<br>interconnection across the separator of 2 different groups of interface relays, using the standard jumper link.<br>Aareat LL0be fami=|0 | 0<br>a<br>ey feee|| JBSEBEEE |BRBSSEG2E<br>Pama) aa<br>eles ‘<br>6.2<br>1 . 8<br>y<br>\ hl \\\ |<br>\\ | Fil \\ |<br>se n N<br>ce S<br>SF =<br>(a)<br>{ft |<br>{|<br>85<br>Sheet of marker tags, plastic, 48 tags, 6 x 10 mm 093.48<br>Hoo' 4 -4 t4<br>=PePen”<br>t 4 4 4<br>oe<br>093.48<br>er er e* ,<br>Sheet of marker tags (CEMBRE Thermal transfer printers) ,48 tags, 6 x 12 mm 060.48<br>be Et piel bel<br>t- | t4 t4<br>t-- | td t4<br>we rH — 4<br>+t| t | t | t |<br>Hct et ie<br>060.48<br>III-2019, www.findernet.com<br>**----- End of picture text -----**<br>
**31**
**39 SERIES**
## **Accessories**
|**Terminal doubler**(for Push-in sockets only)<br>Total load|093.62<br>6 A - 300 V|
|---|---|
|Max. wire size<br>mm2 <br>AWG|**Solid and stranded cable**|
||2 x 1.5|
||2 x 16|
**B**
## _Master_ _**ADAPTER**_
## 093.68.14.1
The _Master_ _**ADAPTER**_ permits the easy connection of A1/A2 terminals of up to 8 _Master_ _**INTERFACE**_ modules to PLC outputs via a 14-Pole ribbon cable, plus simple 2-wire power supply connection ATEX Version.
## **Technical data**
|Rated current (per signal path)<br>A|1|
|---|---|
|Minimum required supply power<br>W|3|
|Nominal voltage (UN)<br>V DC|24|
|Operating range|(0.8…1.1)UN|
|Control logic|Positive switching (to A1)|
|Power supply status indication|Green LED|
|Ambient temperature range<br>°C <br>**Terminals for 24 V control logic**<br>Type of connector<br>~~—~~|–40…+70<br>14 pole, according to IEC 60603-13|
|ATEX version<br>**Terminals for 24 V power supply**<br>Wire strip length<br>mm <br>~~—~~<br>~~\~~<br>>|II 3G Ex nA IIC Gc<br> 9.5|
|Screw torque<br>Nm|0.5|
|Max. wire size<br>solid wire<br>mm2 <br>AWG <br>stranded wire<br>mm2 <br>AWG|1 x 4 / 2 x 1.5|
||1 x 12 / 2 x 16|
||1 x 2.5 / 2 x 1.5|
||1 x 14 / 2 x 16|
**Wiring diagram**
Please see general technical information
**32**
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →