389FXCXC1-12D
RELAY, 3PDT, 150VAC, 28VDC, 20A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SCHNEIDER ELECTRIC/LEGACY RELAY
- Product type: Power Relays
- Contact Configuration:3PDT; Coil Voltage:12VDC; Contact Current:20A; Product Range:389F Series; Relay Mounting:Panel Mount; Coil Type:-; Contact Voltage VAC:150V; Rela 35M3534
- Coil Type: -
- Coil Voltage: 12VDC
- Product Range: 389F Series
- Relay Mounting: Panel Mount
- Coil Resistance: 100ohm
- Contact Current: 20A
- Relay Terminals: Quick Connect
- Contact Material: Silver Alloy
- Contact Voltage VAC: 150V
- Contact Voltage VDC: 28V
- Contact Configuration: 3PDT
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 47.3 € |
| Current stock | 10+ |
| Lead time | 30 days |
:
## 389F Power Relays/One, Two or Three Pole 20-30 Amp Rating (DC and AC)
Oversized current carrying parts Up to 30A switching for to run cooler and last longer power applications 600 V spacing can handle Full range of contact ratings most loads to meet a wide variety of applications Terminals for 0.25” Quick Connects A variety of covers and mounting options Can be customized for unique situations Contact Viewing Window UL Recognized File No. E43641 Square Base
Gold Flashed Contacts
## **General Specifications - (UL 508)**
|**General Specifications - (UL 508)**|**General Specifications - (UL 508)**|**General Specifications - (UL 508)**|**General Specifications - (UL 508)**|
|---|---|---|---|
|**Contact Characteristics**<br>**389FHXX, XHX**<br>**389FXAX, BXX, XBX**<br>**389FCXX, XCX**<br>Number and type of contacts<br>SPST-NO-DM, SPDT-DM-DB<br>SPST, SPDT, DPST, DPDT<br>3PST, 3PDT<br>Contact materials<br>Silver Alloy<br>Silver Alloy<br>Silver Alloy<br>Thermal (carrying) current<br>30 A<br>25 A<br>20 A<br>Maximum switching voltage<br>600 V<br>600 V<br>300 V<br>Switching current @<br>voltage<br>Resistive<br>30 A @ 300 VAC 50/60Hz<br>30 A @ 28 VDC<br>25 A @ 300 VAC 50/60Hz<br>13 A @ 28 VDC<br>20 A @ 150 VAC 50/60Hz<br>13 A @ 28 VDC<br>Ballast<br>25 A @ 277 VAC 50/60Hz<br>20 A @ 277 VAC 50/60Hz<br>20 A @ 150 VAC 50/60Hz<br>6.67 A @ 277 VAC 50/60Hz<br>HP<br>1.5 @ 200-300 V 50/60Hz<br>1 @ 120-199 V 50/60Hz<br>1.5 @ 208-240 V 50/60Hz<br>1 @ 480-600 V 50/60Hz<br>0.5 @ 208-240 V 50/60Hz<br>0.5 @ 120 V 50/60Hz<br>Pilot Duty<br>A600<br>B600<br>B300<br>Minimum switching requirement<br>100 mA @ 5 VDC or 0.5 W<br>100 mA @ 5 VDC or 0.5 W<br>100 mA @ 5 VDC or 0.5 W<br>**Coil Characteristics**<br>~~== —~~||||
||Voltage range<br>12 to 240 VAC<br>12 to 110 VDC<br>12 to 240 VAC<br>12 to 110 VDC||12 to 240 VAC<br>12 to 110 VDC|
||Operating range (% of nominal)<br>85% to 110% AC<br>80% to 110% DC<br>85% to 110% AC<br>80% to 110% DC||85% to 110% AC<br>80% to 110% DC|
||Average consumption<br>3.5 VA<br>1.44 W<br>3.5 VA<br>1.44 W||3.5 VA<br>1.44 W|
||Drop-out voltage threshold<br>10% AC/DC<br>10% AC/DC<br>**Performance Characteristics**||10% AC/DC|
||Electrical life (operations @ rated current)<br>100,000 operations<br>100,000 operations<br>100,000 operations<br>Mechanical life (unpowered)<br>5,000,000 operations<br>5,000,000 operations<br>5,000,000 operations<br>Operating time (response time)<br>20 ms<br>20 ms<br>20 ms<br>Dielectric strength<br>Between coil and<br>contact<br>2000 VAC<br>2000 VAC<br>2000 VAC<br>Between poles<br>2000 VAC<br>2000 VAC<br>2000 VAC<br>Between contacts<br>500 VAC<br>500 VAC<br>500 VAC<br>**Environment**<br>Product certifications<br>Standard version<br>UL, CE, CSA<br>UL, CE, CSA<br>UL, CE, CSA<br>Ambient air temperature<br>around the device<br>Storage<br>-40 to 85°C<br>-40 to 85°C<br>-40 to 85°C<br>Operation<br>-40 to 55°C<br>-40 to 55°C<br>-40 to 55°C<br>Weight<br>88 g<br>88 g<br>88 g<br>|<br>~~——SS~~<br>||||
||**Part Number Builder**|||
||389F<br>XBX<br>C1M|-120<br>A||
||**Series**<br>**Configuration**<br>**Options****|**Voltage**<br>**Current Type**||
||389F =Standard model<br>equipped with flag indicator<br>XAX =SPDT<br>BXX =DPST-NO<br>XBX =DPDT<br>CXX =3PST-NO<br>B =Mounting base<br>C =Plastic dust cover - socket mountable<br>C1 =Side flange mount cover<br>C3 =Top flange cover|Coil Voltage<br>A =AC<br>D =DC||
||XCX =3PDT<br>L =Indicator lamp across coil|||
||HXX =SPST-NO-DM<br>M =Manual operator button on case|||
||XHX =SPDT-DM-DB<br>T =Printed circuit board terminals|||
_Note - Not all iterations of option codes are available and some standard parts may use different nomenclature than outlined in part number builder._
_**Multiple codes may be used._
6/12
Magnecraft Solution Guide 105A
www.magnecraft.com 847-441-2540
**==> picture [134 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
Push Button<br>Available<br>Indicator Lamp<br>**----- End of picture text -----**<br>
## _**NEW!**_
1/4” Solderable Quick-Connects
**==> picture [44 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Indicator Flag<br>**----- End of picture text -----**<br>
Side Flange Cover Option C1
Plain Cover Option C
**==> picture [96 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
NEW!<br>389 Relay with the<br>70-788EL11-1 Socket<br>**----- End of picture text -----**<br>
## **Standard Part Numbers**
## **BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED**
|Nominal Input Voltage|Coil Resistance|Part Number|Contact Configuration|
|---|---|---|---|
|_25 Amp, AC Operated Flange Mount with Push Button_||||
|220/240 VAC, 50/60 Hz|7200 Ω|389FXBXC1M-240A|DPDT|
|110/120 VAC, 50/60 Hz|1700 Ω|389FXBXC1M-120A|DPDT|
|_20 Amp, AC Operated Flange Mount with Push Button_||||
|220/240 VAC, 50/60 Hz|4600 Ω|389FXCXC1M-240A|3PDT|
|110/120 VAC, 50/60 Hz|1200 Ω|389FXCXC1M-120A|3PDT|
|_25 Amp, DC Operated Flange Mount with Push Button_||||
|12 VDC|100 Ω|389FXBXC1M-12D|DPDT|
|24 VDC|400 Ω|389FXBXC1M-24D|DPDT|
|_20 Amp, DC Operated Flange Mount with Push Button_||||
|12 VDC|100 Ω|389FXCXC1M-12D|3PDT|
|24 VDC|400 Ω|389FXCXC1M-24D|3PDT|
|_30 Amp, AC Operated Flange Mount_||||
|110/120 VAC 50/60 Hz|1100 Ω|389FHXXC1-120A|SPST-NO-DM|
|220/240 VAC 50/60 Hz|4300 Ω|389FHXXC1-240A|SPST-NO-DM|
|24 VAC 50/60 Hz|44 Ω|389FXHXC1-24A|SPDT-DM-DB|
|110/120 VAC 50/60 Hz|1100 Ω|389FXHXC1-120A|SPDT-DM-DB|
|_30 Amp, DC Operated Flange Mount_||||
|12 VDC|100 Ω|389FHXXC1-12D|SPST-NO-DM|
|24 VDC|400 Ω|389FHXXC1-24D|SPST-NO-DM|
|12 VDC|100 Ω|389FXHXC1-12D|SPDT-DM-DB|
|24 VDC|400 Ω|389FXHXC1-24D|SPDT-DM-DB|
|_25 Amp, AC Operated Flange Mount_||||
|110/120 VAC 50/60 Hz|1700 Ω|389FXAXC1-120A|SPDT|
|24 VAC 50/60 Hz|72 Ω|389FXBXC1-24A|DPDT|
|110/120 VAC 50/60 Hz|1700 Ω|389FXBXC1-120A|DPDT|
|220/240 VAC 50/60 Hz<br>110/120 VAC 50/60 Hz<br>220/240 VAC 50/60 Hz<br>12 VDC<br>_20 Amp, AC Operated Flange Mount_<br>_25 Amp, DC Operated Flange Mount_|7200 Ω<br>1200 Ω<br>4600 Ω<br>100 Ω|389FXBXC1-240A<br>389FXCXC1-120A<br>389FXCXC1-240A<br>389FXAXC1-12D|DPDT<br>3PDT<br>3PDT<br>SPDT|
|24 VDC|400 Ω|389FXAXC1-24D|SPDT|
|12 VDC|100 Ω|389FXBXC1-12D|DPDT|
|24 VDC|400 Ω|389FXBXC1-24D|DPDT|
|_20 Amp, DC Operated Flange Mount_||||
|12 VDC|100 Ω|389FXCXC1-12D|DPDT|
|24 VDC|400 Ω|389FXCXC1-24D|DPDT|
|_25 Amp, AC Operated Socket Compatible_||||
|220 / 240 VAC 50/60 Hz|7200 Ω|**389FXBXC-240A**|DPDT|
|110/120VAC 50/60 Hz|1700 Ω|**389FXBXC-120A**|DPDT|
|24 VAC 50/60 Hz|72 Ω|**389FXBXC-24A**|DPDT|
|_25 Amp, DC Operated Socket Compatible_||||
|110/125 VDC|8000 Ω|389FXBXC-110/125D|DPDT|
|24 VDC|400 Ω|**389FXBXC-24D**|DPDT|
|_20 Amp, AC Operated Socket Compatible_||||
|220/240 VAC 50/60 Hz|4600 Ω|389FXCXC-240A|DPDT|
|110/120 VAC 50/60 Hz|1200 Ω|**389FXCXC-120A**|DPDT|
|24 VAC 50/60 Hz|46 Ω|**389FXCXC-24A**|DPDT|
|_20 Amp, DC Operated Socket Compatible_||||
|110/125VDC|8000 Ω|389FXCXC-110/125D|DPDT|
|24 VDC|400 Ω|**389FXCXC-24D**|DPDT|
6/13
Magnecraft Solution Guide 105A
## 389F Power Relays/One, Two or Three Pole 20-30 Amp Rating (DC and AC) _continued_
> Push Button _**NEW!**_ Available 1/4” Solderable Indicator Lamp Quick-Connects @ Sey / a UL Recognized Indicator Flag Me. File No. E43641 NE 3 Side Flange Cover Plain Cover
**==> picture [295 x 372] intentionally omitted <==**
**----- Start of picture text -----**<br>
WIRING DIAGRAMS NEMA<br>BOTTOM VIEW IEC<br>2 1 3 1 2 3<br>32 12 22 12 32 22<br>5 4 6 4 5 6<br>34 14 24 14 34 24<br>7 7 9 7 8 9<br>11 11 21 11 31 21<br>A B A B A B<br>A1 A2 A1 A2 A1 A2<br>SPDT DPDT 3PDT<br>5 52 / 3 : 3 ] 3 2 2<br>2 1 3<br>en<br>32 12 22<br>4 6<br>14 24<br>7 9 7<br>11 21 11<br>—=—_{}—= A1A A2B ——_{}+—_= A1A A2B —=—[}—_ A1A — A2B =<br>DPST-NO SPST-NC SPST-NC-(DB)<br>5-73] -4- ><br>1 3<br>ee 12 oe 22 _ = =] =<br>a= 4 Lie 6 a 4 6 a 4 5 6<br>14 24 14 24 14 34 24<br>J 7 I J 8 9<br>11 31 21<br>A B A B A B<br>A1 A2 A1 A2 A1 A2<br>SPDT-NC-NO-(DB-DM) SPST-NO-(DM) 3PST-NO<br>**----- End of picture text -----**<br>
6/14
Magnecraft Solution Guide 105A
www.magnecraft.com 847-441-2540
## PLAIN/PUSH BUTTON COVER STYLE
**==> picture [482 x 633] intentionally omitted <==**
**----- Start of picture text -----**<br>
Option C<br>PUSH<br>BUTTON<br>1.9 MAX<br>1.53 MAX<br>(48.42) 0.28 MAX P.C. TERMINALS<br>(38.89)<br>(7.1)<br>0.046 TYP.<br>1 2 3 (1.16)<br>4 5 6<br>0.026<br>1.4 MAX 7 8 9 (0.66) 0.206 TYP.<br>(35.72) (5.23)<br>A B<br>0.28 MAX 0.156<br>0.25 X 0.032 F (7.1) E 0.288 (3.96)<br>(6.35 X 0.81) (7.31)<br>QUICK CONNECT<br>TERMINALS WITH<br>SOLDER HOLE<br>TOP FLANGE COVER STYLE<br>Option C3 2.53 MAX<br>(64.29)<br>1.71<br>0.31 (43.51)<br>1.9 MAX(48.42) (7.92) 1.53 MAX<br>(38.89)<br>1 2 3 0.14<br>(3.58)<br>4 5 6<br>1.4 MAX 7 8 9<br>(35.72)<br>A B 0.49<br>(12.7)<br>0.06 0.25 X 0.032<br>a (6.35 X 0.81)<br>(1.59) QUICK CONNECT<br>TERMINALS WITH<br>SOLDER HOLE SIDE FLANGE COVER STYLE<br>Option C1<br>2.9 MAX<br>(73.82)<br>0.37 MAX<br>2.5 MAX<br>(9.53)<br>(63.5)<br>1.9 MAX<br>0.18 MAX (48.42) 0.28 MAX<br>(4.76) (7.1)<br>0.62 TYP.<br>(15.88)<br>0.15 TYP.<br>(3.96)<br>0.25 X 0.032<br>1 2 3 (6.35 X 0.81)QUICK CONNECT<br>4 5 6 TERMINALS WITHSOLDER HOLE<br>7 8 9 1.4 MAX<br>(35.72)<br>0.06 MAX<br>A B (1.59)<br>1.53 MAX<br>a (38.89) E<br>**----- End of picture text -----**<br>
6/15
Magnecraft Solution Guide 105A
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →