Image not available
Illustrative purposes only
38.51.0.048.0060
General Purpose Relay, 38 Series, Interface, SPDT, 48 V, 6 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type: Power Relays
- Contact Configuration:SPDT; Coil Voltage:48V; Contact Current:6A; Product Range:38 Series; Relay Mounting:DIN Rail; Coil Type:AC / DC; Contact Voltage VAC:250VAC; Relay Terminals:Screw; Contact V
- SVHC: No SVHC (04-Feb-2026)
- Coil Type: AC / DC
- Coil Voltage: 48VAC/VDC
- Product Range: 38 Series
- Relay Mounting: DIN Rail
- Coil Resistance: -
- Contact Current: 6A
- Relay Terminals: Screw
- Contact Material: Silver Nickel
- Contact Voltage VAC: 250VAC
- Contact Voltage VDC: 30V
- Approvals & Standards: CE, CSA, UL
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 17.48 € |
| Current stock | 10+ |
| Lead time | 30 days |
**38 SERIES** ## **Common features** - Instant ejection of relay by plastic retaining clip **EMR Electromechanical Relays** **SSR Solid State Relays** - Integral coil indication and protection circuit - 35 mm rail (EN 60715) mounting ## **6.2 mm wide** - **EMR - DC, AC or AC/DC coil versions** - **SSR - DC or AC/DC input versions** - Screw and Screwless terminal options ## **6.2 mm wide** - **Special coil/input leakage current suppression types** - **EMR - AC or AC/DC coil versions** - **SSR - AC or AC/DC input versions** - Screw and Screwless terminal options **==> picture [54 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 38.51/38.61<br>**----- End of picture text -----**<br> **==> picture [165 x 148] intentionally omitted <==** **----- Start of picture text -----**<br> 38.81/38.91<br>• Single solid state output:<br>Options 0.1 A/48 V DC, 6 A/24 V DC, 2 A/240 V AC<br>• Silent, high speed switching<br>• Long electrical life<br>**----- End of picture text -----**<br> **==> picture [73 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> • 1 CO - 6 A/250 V AC<br>**----- End of picture text -----**<br> **Page 1 Page 2 38.51.3… - 38.61.3… 38.81.3… - 38.91.3…** • Single solid state output: Options **0.1 A/48 V DC, 6 A/24 V DC, 2 A/240 V AC** • Silent, high speed switching **==> picture [73 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> • 1 CO - 6 A/250 V AC<br>**----- End of picture text -----**<br> **B** - Long electrical life ## **6.2 mm wide** ## **38.21** **Page 1** ## **38.21…9024-8240** **==> picture [25 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Page 2<br>**----- End of picture text -----**<br> - **Timed Interface module** - **4 functions & 4 time scales 0.1 s…6 h** - **EMR - AC/DC (12 or 24 V) supply versions** - **SSR - AC/DC (24 V) supply** - Screw terminals ## **14 mm wide** - **2 pole 8 A or 1 pole 16 A** - **EMR - DC or AC/DC coil versions** - **SSR - DC input versions** - Screw and Screwless terminal options **==> picture [73 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> • 1 CO - 6 A/250 V AC<br>**----- End of picture text -----**<br> ## **38.01/38.52/38.11/38.62** **==> picture [78 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> • 1 CO - 16 A/250 V AC<br>• 2 CO - 8 A/250 V AC<br>**----- End of picture text -----**<br> **Page 3** **Page 4** **==> picture [125 x 39] intentionally omitted <==** **----- Start of picture text -----**<br> • Single solid state output:<br>Options 6 A/24 V DC, 2 A/240 V AC<br>• Silent, high speed switching<br>• Long electrical life<br>**----- End of picture text -----**<br> **==> picture [165 x 174] intentionally omitted <==** **----- Start of picture text -----**<br> Page 3<br>38.31/38.41<br>®<br>• Single solid state output:<br>Options 5 A/24 V DC, 3 A/240 V AC<br>• Silent, high speed switching<br>• Long electrical life<br>Page 5<br>**----- End of picture text -----**<br> **38 SERIES** **1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide.** **==> picture [40 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> 38.51/61<br>**----- End of picture text -----**<br> ## **38.51.3/38.61.3** ## **Ideal interface for PLC and electronic systems** - Sensitive DC coil or AC/DC coil versions - Integral coil indication and protection circuit - Instant ejection of relay using plastic retaining clip - UL Listing (certain relay/socket combinations) - 35 mm rail (EN 60715) mounting 38.51/38.51.3 38.61/38.61.3 Screw terminal Screwless terminal **==> picture [108 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> • 1 pole electromechanical relay<br>**----- End of picture text -----**<br> - Screw terminal and screwless terminal - 35 mm rail (EN 60715) mounting - Leakage current suppression - 1 pole electromechanical relay - Screw terminal and screwless terminal **B** - 35 mm rail (EN 60715) mounting - Special version for max ambient temperature +70 °C. - ** Maximum ambient temperature limitations apply in the case of adjacent mounting of modules, where the coil is energised with a duty cycle of - ≥ 50 % or where the ON time exceeds 1 hour: - +55 °C: applies to groups limited to 2 adjacent modules and where each group is separated by an air gap ≥ 6.2 mm. - +30 °C: applies to a group of more than 2 adjacent modules. For outline drawing see page 13 |For outline drawing see page 13||| |---|---|---| |**Contact specification**<br>Contact configuration||1 CO (SPDT)<br>1 C~~O~~(~~S~~P~~DT~~)| |Rated current/<br>Maximumpeak current||A<br>6/10<br>6/10| |Rated voltage/<br>Maximum switchingvoltage<br>V AC<br>250/400<br>250/400<br>Rated load AC1<br>VA<br>1500<br>1500<br>Rated load AC15 (230 V AC)<br>VA<br>300<br>300<br>Single phase motor rating(230 V AC)<br>kW<br>0.185<br>0.185<br>BreakingcapacityDC1: 30/110/220 V<br>A<br>6/0.2/0.12<br>6/0.2/0.12<br>Minimum switchingload<br>mW (V/mA)<br>500 (12/10)<br>500 (12/10)<br>Standard contact material<br>AgNi<br>AgNi<br>**Coil specification**<br>~~Ce~~<br>~~eo~~<br>~~Pe~~<br>~~Pe~~||| |Nominal voltage (UN)<br>Rated power AC/DC|VA (50 Hz)/W|V AC/DC<br>12 - 24 - 48 - 60 - (110…125) - (220…240)**<br>(110…125)<br>—<br>V AC<br>(230…240)*<br>—<br>(230…240)<br>V DC<br>6 - 12 - 24 - 48 - 60 (non polarized)<br>—<br>—<br>VA (50 Hz)/W<br>See page 9<br>1/1<br>0.5/—<br>~~DR~~<br>~~DRDR~~| |Operating range||AC/DC<br>(0.8…1.1)UN<br>(94…138)V<br>—<br>~~DR~~| |Holdingvoltage||AC<br>(184…264)V<br>—<br>(184…264)V<br>DC<br>(0.8…1.2)UN<br>—<br>AC/DC<br>0.6 UN/ 0.6 UN<br>0.6 UN/ 0.6 UN<br>~~pe~~<br>~~Pe~~| |Must drop-out voltage||AC/DC<br>0.1 UN/ 0.05 UN<br>44 V<br>72 V| |**Technical data**||| |Mechanical life AC/DC||cycles<br>10 · 106<br>10 · 106| |Electrical life at rated load AC1||cycles<br>60 · 103<br>60 · 103<br>~~DR~~| |Operate/release time||ms<br>5/6<br>5/6<br>~~DR~~| |Insulation between coil||| |and contacts(1.2/50µs)<br>Dielectric strength<br>between open contacts<br>Ambient temperature range (UN≤ 60 V/> 60 V)<br>Protection category<br>**Approvals relay**(according to type)||kV<br>6(8 mm)<br>6(8 mm)<br>V AC<br>1000<br>1000<br>≤ 60 V/> 60 V)<br>°C<br>–40…+70/–40…+55<br>—/–40…+55<br>IP 20<br>IP 20<br>~~es~~<br>C€@<br>HAL@RINAAdis| **1** **38 SERIES** ## **Single output - solid state relay interface modules, 6.2 mm wide.** ## **38.81/38.91** ## **38.81.3/38.91.3** ## **Ideal interface for PLC and electronic systems** - DC, AC or AC/DC input versions - Supplied with integral coil indication and protection circuit - Silent, high switching speed and long electrical life - **B** • Instant ejection of relay using plastic retaining clip - UL Listing (certain relay/socket combinations) - 35 mm rail (EN 60715) mounting ## 38.81/38.81.3 38.91/38.91.3 Screw terminal Screwless terminal - AC or DC output switching - SSR relay - DC input voltage - Screw terminal and screwless terminal - 35 mm rail (EN 60715) mounting - Leakage current suppression - AC or DC output - SSR relay - AC or AC/DC input voltage - Screw terminal and screwless terminal - 35 mm rail (EN 60715) mounting For outline drawing see page 13 ## **Output specification** |Contact configuration||||1 NO (SPST-NO)||||||1 NO (SPST-NO)|| |---|---|---|---|---|---|---|---|---|---|---|---| |Rated current/<br>Maximumpeak current(10 ms)||A|6/50|0.1/0.5||2/80||6/50||0.1/0.5|2/80| |Rated voltage/<br>Maximum blockingvoltage||V|24/33 DC|48/53 DC|240/— AC|||24/33 DC||48/53 DC|240/— AC| |Switchingvoltage range||V|(1.5…33)DC|(1.5…53)DC|(12…275)AC|||(1.5…33)DC||(1.5…53)DC|(12…275)AC| |Repetitivepeak off-state voltage||Vpk|—|—||800||—||—|800| |Minimum switchingcurrent||mA|1|0.05||35||1||0.05|35| |Max. “OFF-state” leakage current||mA|0.001|0.001||1.5||0.001||0.001|1.5| |Max. “ON-state” voltage drop||V|0.4|1||1.6||0.4||1|1.6| |**Input specification**<br>Nominal voltage (UN)||V AC||—||||||230…240|| |||V DC||6 - 24 - 60||||||—|| ||V AC/DC|V AC/DC|(110…125) - (220…240)|||||||110…125|| |Operatingrange||V DC||Seepage 10||||||Seepage 10|| |Control current||mA||Seepage 10||||||Seepage 10|| |Release voltage<br>**Technical data**||V DC||See page 10||||||See page 10|| |Operate/release time: ON/OFF (DC input)||ms|0.2/0.6|0.04/0.11||12/12||0.2/0.6||0.04/0.11|12/12| |Dielectric strength|||||||||||| |between input/output||V AC||2500||||||2500|| |Ambient temperature range||°C||–20…+55||||||–20…+55|| |Environmentalprotection||||IP20||||||IP20|| |**Approvals relay**(according to type)||||C€|@|EAL®|®|RINA|CAL<br>C|CAL<br>US|| **2** **38 SERIES** **B** **Slim timed interface module, 6.2 mm wide. 1 pole, 6 A - electromechanical relay 1 output, 2 A DC or AC - solid state relay** **==> picture [26 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 38.21<br>**----- End of picture text -----**<br> ## **38.21…9024-8240** - Electromechanical or solid state output - Multi-functions timer - AC/DC supply - 4 time scales from 0.1 s to 6 h - Instant ejection of relay using plastic retaining clip - 6.2 mm wide, 35 mm rail (EN 60715) mounting 38.21 Screw terminal - 1 pole electromechanical output relay - DC or AC solid state output relays • 12 or 24 V AC/DC supply • 24 V AC/DC supply voltage • Screw terminal • Screw terminal • 35 mm rail (EN 60715) mounting • 35 mm rail (EN 60715) mounting **AI:** On-delay ~~wee~~ **AI:** On-delay 7 ~~ee~~ ‘fj | !| I **DI:** Interval **DI:** Interval **GI:** Pulse delayed **GI:** Pulse delayed **SW:** Symmetrical flasher **SW:** Symmetrical flasher (starting pulse on) i (starting pulse on) For outline drawing see page 13 ## **Contact specification** ||Contact configuration||1 CO (SPDT)|||—|—| |---|---|---|---|---|---|---|---| ||Rated current/<br>Maximumpeak current|A|6/10|||—|| ||Rated voltage/<br>Maximum switchingvoltage|V AC|250/400|||—|| ||Rated load AC1|VA|1500|||—|| ||BreakingcapacityDC1: 30/110/220 V<br>A||6/0.2/0.12|||—|| ||Minimum switchingload|mW (V/mA)|500 (12/10)|||—|| ||Standard contact material||AgNi|||—|| ||**Output specification**<br>Output configuration||—|||**DC output (…9024)**<br>1 NO (SPST-NO)|**AC output (…8240)**<br>1 NO (SPST-NO)| ||Rated current/Maximumpeak current<br>A||—|||6/50|2/80| ||Rated voltage/<br>Maximum blockingvoltage|V|—|||(24/33)DC|(240/—)AC| ||Switchingvoltage range|V|—|||(1.5…33)DC|(12…275)AC| ||Repetitivepeak off-state voltage<br>Vpk||—|||—|800| ||Minimum switchingcurrent|mA||||1|35| ||Max. “OFF-state” leakage current<br>mA||—|||0.001|1.5| ||Max. “ON-state” voltage drop|V|—|||0.4|1.6| ||**Supply specification**<br>Nominal voltage (UN)|V AC (50/60 Hz)/DC|12 - 24|||24|| ||Ratedpower|VA/W|0.5|||0.5|| ||Operating range|AC|(0.8…1.1)UN|||(0.8…1.1)UN|| ||**Technical data**|DC|(0.8…1.1)UN|||(0.8…1.1)UN|| ||Specified time range||(0.1…3)s, (3…60)s, (1…20)min, (0.3…6)h||||| ||Repeatability|%||± 1|± 1||| |X-2017, www.findernet.com|Recoverytime<br>ms<br>Settingaccuracy-full range<br>%<br>Ambient temperature<br>°C<br>Protection category<br>**Approvals relay**(according to type)||–40…+70<br>C€|≤ 50<br>5%<br>IP 20<br>FAL||–20…+55<br>®<br>cAdus|| **3** **38 SERIES** **Electromechanical relay interface modules, 14 mm wide.** ## **38.01/38.11** **==> picture [54 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 38.52/38.62<br>**----- End of picture text -----**<br> ## **38.01 and 38.11 - 1 Pole 16 A 38.52 and 38.62 - 2 Pole 8 A** ## **Ideal interface for PLC and electronic systems** - Sensitive DC coil or AC/DC coil versions - Integral coil indication and protection circuit - Instant ejection of relay using plastic retaining - **B** clip - UL Listing (certain relay/socket combinations) - 35 mm rail (EN 60715) mounting - Screw terminal and screwless terminal - 1 pole electromechanical relay - 35 mm rail (EN 60715) mounting - Screw terminal and screwless terminal - 2 pole electromechanical relay - 35 mm rail (EN 60715) mounting 38.01/52 38.11/62 Screw terminal Screwless terminal - For currents > 10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). For outline drawing see page 13 ## **Contact specification** |Contact configuration||1 CO (DPDT)|||2 CO (DPDT)| |---|---|---|---|---|---| |Rated current/Maximumpeak current<br>A||16*/30|||8/15| |Rated voltage/<br>Maximum switchingvoltage|V AC|250/400|||250/400| |Rated load AC1|VA|4000|||2000| |Rated load AC15 (230 V AC)|VA|750|||400| |Singlephase motor rating(230 V AC)|(230 V AC)<br>kW|0.5|||0.3| |BreakingcapacityDC1: 30/110/220 V<br>A||16/0.3/0.12|||8/0.3/0.12| |Minimum switchingload|mW (V/mA)|300 (5/5)|||300 (5/5)| |Standard contact material<br>**Coil specification**<br>Nominal voltage (UN)|V AC/DC|AgNi<br>24 - 60 - (110…125) - (220…240)||AgNi<br>24 - 60 - (110…125) - (220…240)|| ||V AC|230…240|||230…240| ||V DC|12 - 24 - 60|||12 - 24 - 60| |Ratedpower AC/DC|VA (50 Hz)/W|Seepage 9|||Seepage 9| |Operating range|AC/DC|0.8…1.1|||0.8…1.1| ||DC|(0.8…1.2)UN|||(0.8…1.2)UN| |Holdingvoltage|AC/DC|0.6 UN/ 0.6 UN|||0.6 UN/ 0.6 UN| |Must drop-out voltage<br>**Technical data**|AC/DC|0.1 UN/ 0.05 UN|||0.1 UN/ 0.05 UN| |Mechanical life AC/DC|cycles|10 · 106|||10 · 106| |Electrical life at rated load AC1|cycles|50 · 103|||60 · 103| |Operate/release time|ms|8/10|||8/10| |Insulation between coil|||||| |and contacts(1.2/50µs)<br>kV<br>Dielectric strength<br>between open contacts<br>V AC<br>Ambient temperature range (UN≤ 60 V/> 60 V) °C<br>Protection category<br>**Approvals relay**(according to type)||6(8 mm)<br>1000<br>–40…+70/–40…+55<br>IP 20<br>C€@|FAL@|@RINA|6(8 mm)<br>1000<br>–40…+70/–40…+55<br>IP 20<br>®<br>cAXis| **4** **38 SERIES** **B** **Single output - solid state relay interface modules, 14 mm wide.** ## **38.31/38.41** **Ideal interface for PLC and electronic systems** - DC input versions - Supplied with integral coil indication and protection circuit - Silent, high switching speed and long electrical life - Instant ejection of relay using plastic retaining clip - UL Listing (certain relay/socket combinations) - 35 mm rail (EN 60715) mounting - Screw terminal and screwless terminal - AC or DC output switching - SSR relay - DC input voltage **==> picture [287 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> 38.31 38.41 • 35 mm rail (EN 60715) mounting<br>Screw terminal Screwless terminal<br>**----- End of picture text -----**<br> |For outline drawing see page 13|||| |---|---|---|---| |**Output specification**|||| |Contact configuration|||1 NO (SPST-NO)<br>1 NO (SPST-NO)| |Rated current/<br>Maximumpeak current(10 ms)||A|5/40<br>3/40| |Rated voltage/<br>Maximum blockingvoltage||V|(24/35)DC<br>(240/—)AC| |Switchingvoltage range||V|(1.5…24)DC<br>(12…275)AC<br>~~ee~~| |Repetitivepeak off-state voltage<br>Minimum switchingcurrent||Vpk<br>mA|—<br>600<br>1<br>50<br>~~ee~~<br>~~ee~~| |Max. “OFF-state” leakage current||mA|0.01<br>1<br>~~ee~~| |Max. “ON-state” voltage drop||V|0.3<br>1.1| |**Input specification**<br>Nominal voltage (UN)|V AC/DC|V AC/DC|24| |Operatingrange||V DC<br>V DC|12 - 24<br>Seepage 10<br>~~ee~~<br>~~ee~~| |Control current||mA|Seepage 10<br>~~eee~~| |Release voltage<br>**Technical data**||V DC|See page 10| |Operate/release time: ON/OFF (DC input)||ms|0.05/0.25<br>12/12| |Dielectric strength|||| |between input/output||V AC|2500| |Ambient temperature range||°C|–20…+55<br>~~eee~~| |Environmentalprotection|||IP20<br>~~a~~| |**Approvals relay**(according to type)|||C€@<br>FAL®@RINAA\ts| **5** **38 SERIES** **B** ## **Ordering information** ## **Electromechanical relay - 1 or 2 Pole** Example: 38 series screw terminal relay interface module, 1 CO (SPDT), sensitive 12 V DC coil. **A B C D 3 8 . 5 1 . 7 . 0 1 2 . 0 0 5 0 Series D: Special versions** ## **D: Special versions** 0 = Standard ## **Type** - 0 = Electromechanical 16 A relay, with screw terminal - 1 = Electromechanical 16 A relay, with screwless terminal - 2 = Timer multifunction (AI, DI, GI, SW), with screw terminal - 5 = Electromechanical relay, with screw terminal - 6 = Electromechanical relay, with screwless terminal ## **C: Options** - 5 = Standard DC - 6 = Standard AC or AC/DC ## **B: Contact circuit** - 0 = CO (nPDT) ## **A: Contact material** - 0 = AgNi Standard - 4 = AgSnO2 - 5 = AgNi + Au ## **No. of poles** 1 = 1 pole, 6 or 16 A 2 = 2 pole, 8 A ## **Coil version** - 0 = AC (50/60 Hz)/DC - 3 = Leakage current suppression for (110…125)V AC/DC - (230…240)V AC - 7 = Sensitive DC, (6, 12, 24, 48, 60)V only - 8 = AC (50/60 Hz) ## **Coil voltage** See coil specifications **Selecting features and options: only combinations in the same row are possible.** |**Type**|**Coil version**|**A**|**B**|**C**|**D**| |---|---|---|---|---|---| |38.01/11|7|0 - 4|0|5|0| |38.01/11|0 - 8|0 - 4|0|6|0| |38.51/61|7|0 - 4 - 5|0|5|0| |38.51/61|0 - 3 - 8|0 - 4 - 5|0|6|0| |38.52/62|7|0 - 5|0|5|0| |38.52/62|0 - 8|0 - 5|0|6|0| |38.21|0|0|0|6|0| **6** **38 SERIES** **B** ## **Ordering information** ## **Solid state relay - Single output - 6.2 & 14 mm wide** Example: 38 series screw terminal SSR relay interface module, 6.2 mm wide, 6 A output, 24 V DC input. **3 8 . 8 1 . 7 . 0 2 4 . 9 0 2 4** ## **Series** ## **Type** - 21 = Timer SSR 6.2 mm wide, with screw terminal - 31 = SSR 14 mm wide, with screw terminal ## **Output version** 9024 = 6 A - 24 V DC (38.21, 38.81 & 38.91) 9024 = 5 A - 24 V DC (38.31 & 38.41) 7048 = 0.1 A - 48 V DC (38.81 & 38.91) 8240 = 2 A - 240 V AC (38.21, 38.81 & 38.91) 8240 = 3 A - 240 V AC (38.31 & 38.41) - 41 = SSR 14 mm wide, with screwless terminal - 81 = SSR 6.2 mm wide, with screw terminal - 91 = SSR 6.2 mm wide, with screwless terminal ## **Input version** 0 = AC/DC - 3 = Leakage current suppression for - (110…125)V AC/DC and (230…240)V AC SSR only - 7 = DC, (6, 24, 60)V SSR only ## **Input voltage** See input specifications ## **Selecting features and options: only combinations in the same row are possible.** |**Type**|**Input version**|**Output version**| |---|---|---| |38.81/91|7|9024 - 7048 - 8240| |38.81/91|0 - 3|9024 - 7048 - 8240| |38.31/41|0 - 7|9024 - 8240| |38.21|0|9024 - 8240| **7** **38 SERIES** ## **Technical data - 1 & 2 Pole Electromechanical Relays** ## **Insulation** ||Insulation according to EN 61810-1<br>insulation rated voltage<br>rated impulse withstand voltage<br>pollution degree<br>overvoltage category<br>Insulation between coil and contacts (1.2/50µs)<br>Dielectric strength between open contacts<br>**Conducted disturbance immunity**|insulation rated voltage|V|250|250|400|400| |---|---|---|---|---|---|---|---| |||rated impulse withstand voltage|kV|4||4|| |||pollution degree||3||2|| |**B**||overvoltage category||III||III|| ||||kV|6 (8 mm)|||| ||||V AC|1000|||| ||||||||| ||Burst (5…50)ns, 5 kHz, on A1 - A2 accordingto EN 61000-4-4<br>Surge (1.2/50 µs) on A1 - A2 (differential mode) according to EN 61000-4-5<br>**Other data**<br>Bounce time: NO/NC<br>Vibration resistance (10…55)Hz: NO/NC<br>Power lost to the environment<br>without contact current<br>with rated current<br>**Terminals**<br>Wire striplength<br>|||level 4 (4 kV)|||| |||||level 3 (2 kV)|||| |||||**1 Pole 6 A**||**1 Pole 16 A - 2 Pole 8 A**|| ||||ms|1/6||2/5|| ||||g|10/5||15/2|| |||without contact current|W|0.2 (12 V) - 0.9 (240 V)||0.5 (24 V) - 0.9 (240 V)|| |||with rated current|W|0.5 (12 V) - 1.5 (240 V)||1.3 (24 V) - 1.7 (240 V)|| |||||**38.21 / 38.51**||**38.61**|| ||||mm <br>|10<br>||10|| ||Screw torque<br>Max. wire size<br>Wire striplength<br>||Nm <br>mm2|0.5<br>solid cable<br>stranded cable||—<br>solid cable<br>stranded cable|| |||||1 x 2.5 / 2 x 1.5|1 x 2.5 / 2 x 1.5|1 x 2.5|1 x 2.5| ||||AWG <br>mm <br>|1 x 14 / 2 x 16|1 x 14 / 2 x 16|1 x 14|1 x 14| |||||**38.01 / 38.52**||**38.11 / 38.62**|| |||||10<br>||10|| ||Screw torque<br>Max. wire size||Nm <br>mm2|0.5<br>solid cable<br>stranded cable||—<br>solid cable<br>stranded cable|| |||||1 x 2.5 / 2 x 1.5|1 x 2.5 / 2 x 1.5|1 x 2.5|1 x 2.5| ||||AWG|1 x 14 / 2 x 16|1 x 14 / 2 x 16|1 x 14|1 x 14| ## **Contact specification - 1 & 2 Pole Electromagnetic Relays** **F 38 - Electrical life (AC) v contact current** , 1 Pole 6 A **==> picture [253 x 295] intentionally omitted <==** **----- Start of picture text -----**<br> Resistive load - cos ϕ = 1<br>Inductive load - cos ϕ = 0.4<br>F 38 - Electrical life (AC) v contact current , 1 Pole 16 A and 2 Pole 8 A<br>Resistive load - cos ϕ = 1<br>Inductive load - cos ϕ = 0.4<br>Resistive load - cos ϕ = 1<br>Inductive load - cos ϕ = 0.4<br> : 2 Pole 8 A<br> : 1 Pole 16 A<br>Cycles<br>Cycles<br>**----- End of picture text -----**<br> **H 38 - Maximum DC1 breaking capacity** , 1 Pole 6 A **==> picture [253 x 277] intentionally omitted <==** **----- Start of picture text -----**<br> DC voltage (V)<br>H 38 - Maximum DC1 breaking capacity , 1 Pole 16 A and 2 Pole 8 A<br>38.01/11 limit current<br>38.52/62 limit current<br>2 contacts in series<br>single contact<br>DC voltage (V)<br>DC breaking current (A)<br>DC breaking current (A)<br>**----- End of picture text -----**<br> - When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 60 · 10[3] (1 Pole) or ≥ 80 · 10[3 ] (2 Pole) can be expected. - In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. **8** **38 SERIES** **Coil specifications - 1 Pole 6 A Electromechnical Relay** **Coil data sensitive DC** , 1 Pole **Coil data AC/DC** , 1 Pole |Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Rated coil<br>consumption<br>Iat UN|Power<br>consumption<br>P at UN||Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Rated coil<br>consumption<br>Iat UN|Power<br>consumption<br>P at UN| |---|---|---|---|---|---|---|---|---|---|---|---|---| |V||V|V|mA|W||V||V|V|mA|VA/W| |6|**7**.006|4.8|7.2|35|0.2||12|**0**.012|9.6|13.2|16|0.2/0.2| |12|**7**.012|9.6|14.4|15.2|0.2||24|**0**.024|19.2|26.4|12|0.3/0.2| |24|**7**.024|19.2|28.8|10.4|0.3||48|**0**.048|38.4|52.8|6.9|0.3/0.3| |48|**7**.048|38.4|57.6|6.3|0.3||60|**0**.060|48|66|7|0.5/0.5| |60|**7**.060|48|72|7|0.4||110…125|**0**.125|88|138|5(*)|0.6/0.6(*)| ||||||||220…240|**0**.240|176|264|4(*)|1/0.9(*)| **B** (*) Rated coil consumption and power consumption values relate to UN = 125 and 240 V. **Coil data AC,** 1 Pole (indicated for max ambient temperature +70 °C) |Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br><br>Umin<br>Umax|Operating range<br><br>Umin<br>Umax|Rated coil<br>consumption<br><br>Iat UN|Power<br>consumption<br>P at UN| |---|---|---|---|---|---| |V||V|V|mA|VA/W| |(230…240)AC|**8**.240|184|264|3|0.7/0.3| **Coil data, leakage current suppression types,** 1 Pole |Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br><br>Umin<br>Umax|Operating range<br><br>Umin<br>Umax|Rated coil<br>consumption<br><br>Iat UN|Power<br>consumption<br>P at UN| |---|---|---|---|---|---| |V||V|V|mA|VA/W| |(110…125)AC/DC|**3**.125|94|138|8(*)|1/1(*)| |(230…240)AC|**3**.240|184|264|7(*)|1.7/0.5(*)| (*) Rated coil consumption and power consumption values relate to UN = 125 and 240 V. The 38 Series interface modules (supply version 3) have built-in leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110…125)V AC and (230…240)V AC. This problem can occur, for example, when connecting the interface modules to PLC‚s with triac outputs or when connecting via relatively long cables. **Coil specifications - 1 Pole 16 A and 2 Pole 8 A Electromechanical Relay** |**Coil data sensitive DC,**1 Pole 16 A and 2 Pole 8 A<br>Nominal<br>voltage<br>Coil<br>code<br>Operating range<br>Rated coil<br>consumption<br>Power<br>consumption<br>UN<br>Umin<br>Umax<br>Iat UN<br>P at UN|**Coil data sensitive DC,**1 Pole 16 A and 2 Pole 8 A<br>Nominal<br>voltage<br>Coil<br>code<br>Operating range<br>Rated coil<br>consumption<br>Power<br>consumption<br>UN<br>Umin<br>Umax<br>Iat UN<br>P at UN|**Coil data sensitive DC,**1 Pole 16 A and 2 Pole 8 A<br>Nominal<br>voltage<br>Coil<br>code<br>Operating range<br>Rated coil<br>consumption<br>Power<br>consumption<br>UN<br>Umin<br>Umax<br>Iat UN<br>P at UN|**Coil data sensitive DC,**1 Pole 16 A and 2 Pole 8 A<br>Nominal<br>voltage<br>Coil<br>code<br>Operating range<br>Rated coil<br>consumption<br>Power<br>consumption<br>UN<br>Umin<br>Umax<br>Iat UN<br>P at UN|**Coil data sensitive DC,**1 Pole 16 A and 2 Pole 8 A<br>Nominal<br>voltage<br>Coil<br>code<br>Operating range<br>Rated coil<br>consumption<br>Power<br>consumption<br>UN<br>Umin<br>Umax<br>Iat UN<br>P at UN|**Coil data sensitive DC,**1 Pole 16 A and 2 Pole 8 A<br>Nominal<br>voltage<br>Coil<br>code<br>Operating range<br>Rated coil<br>consumption<br>Power<br>consumption<br>UN<br>Umin<br>Umax<br>Iat UN<br>P at UN|**Coil data sensitive DC,**1 Pole 16 A and 2 Pole 8 A<br>Nominal<br>voltage<br>Coil<br>code<br>Operating range<br>Rated coil<br>consumption<br>Power<br>consumption<br>UN<br>Umin<br>Umax<br>Iat UN<br>P at UN|**Coil data AC/DC,**1 Pole 16 A and 2 Pole 8 A|**Coil data AC/DC,**1 Pole 16 A and 2 Pole 8 A|**Coil data AC/DC,**1 Pole 16 A and 2 Pole 8 A|**Coil data AC/DC,**1 Pole 16 A and 2 Pole 8 A|**Coil data AC/DC,**1 Pole 16 A and 2 Pole 8 A|**Coil data AC/DC,**1 Pole 16 A and 2 Pole 8 A| |---|---|---|---|---|---|---|---|---|---|---|---|---| |Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax||Rated coil<br>consumption<br>Iat UN|Power<br>consumption<br>P at UN||Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax||Rated coil<br>consumption<br>Iat UN|Power<br>consumption<br>P at UN| |V||V|V|mA|W||V||V|V|mA|W| |12|**7**.012|9.6|14.4|41|0.5||24|**0**.024|19.2|26.4|20|0.5/0.5| |24|**7**.024|19.2|28.8|19.5|0.5||60|**0**.060|48|66|7.1|0.5/0.5| |60|**7**.060|48|72|8|0.5||110…125|**0**.125|88|138|4.6|0.6/0.6| ||||||||220…240|**0**.240|184|264|3.8|0.9/0.9| ||||||||**Coil data AC,**1 Pole 16 A and 2 Pole 8 A|||||| ||||||||Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax||Rated coil<br>consumption<br>Iat UN|Power<br>consumption<br>P at UN| ||||||||V||V|V|mA|VA/W| ||||||||230…240|**8**.230|184|264|5.3|1.2/0.6| ## **Coil specification - 1 & 2 Pole Electromagnetic Relays** ## **R 38 - DC coil operating range v ambient temperature** 1 Pole and 2 Pole **==> picture [188 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2<br>3<br>4<br>**----- End of picture text -----**<br> **1 -** Max. permitted coil voltage at nominal load (DC coil). **2 -** Max. permitted coil voltage at nominal load (AC/DC coils U ≤ 60 V). **3 -** Max. permitted coil voltage at nominal load (AC/DC coils U > 60 V). **4 -** Min pick-up voltage with coil at ambient temperature. **9** **38 SERIES** ## **Technical data - Solid State Relays** ||**Other data**|||**38.81/38.91**|**38.81/38.91**|**38.31/38.41**|**38.31/38.41**| |---|---|---|---|---|---|---|---| ||Power lost to the environment|without output current|W|0.25 (24 V DC)||0.5|| |||with rated current|W|0.4||2.2 (DC output)/3 (AC output)|| ||**Terminals**|||**38.81**||**38.91**|| |**B**|||||||| ||Wire striplength<br>||mm <br>|10<br>||10|| ||Screw torque<br>Max. wire size<br>Wire striplength<br>||Nm|0.5<br>solid cable<br>stranded cable||—<br>solid cable<br>stranded cable|| ||||mm2|1 x 2.5 / 2 x 1.5|1 x 2.5 / 2 x 1.5|1 x 2.5|1 x 2.5| ||||AWG <br>mm <br>|1 x 14 / 2 x 16|1 x 14 / 2 x 16|1 x 14|1 x 14| |||||**38.31**||**38.41**|| |||||10<br>||10|| ||Screw torque<br>Max. wire size||Nm|0.5<br>solid cable<br>stranded cable||—<br>solid cable<br>stranded cable|| ||||mm2|1 x 2.5 / 2 x 1.5|1 x 2.5 / 2 x 1.5|1 x 2.5|1 x 2.5| ||||AWG|1 x 14 / 2 x 16|1 x 14 / 2 x 16|1 x 14|1 x 14| ## **Input specifications - Solid State Relays type 38.81 and 38.91 - 6.2 mm wide** ## **Input data DC** |Nominal|Supply|Operating range|Operating range|Release|Rated coil|Power| |---|---|---|---|---|---|---| |voltage|code|||voltage|consumption|consumption| |UN||Umin|Umax|U|Iat UN|P| |V||V|V|V|mA|W| |6|**7**.006|5|7.2|2.4|7|0.2| |24|**7**.024|16.8|30|10|10.5|0.3| |60|**7**.060|35.6|72|20|6.5|0.4| ## **Input data AC/DC** |Nominal|Supply|Operating range|Operating range|Release|Rated coil|Power| |---|---|---|---|---|---|---| |voltage|code|||voltage|consumption|consumption| |UN||Umin|Umax|U|Iat UN|P| |V||V|V|V|mA|VA/W| |110…125|**0**.125|88|138|22|5.5*|0.7/0.7| |220…240|**0**.240|184|264|44|3.5*|1/0.9| (*) Rated coil consumption and power consumption values relate to UN = 125 and 240 V. ## **Input data - Leakage current suppression types** |Nominal<br>voltage<br>UN|Supply<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Release<br>voltage<br>U|Rated coil<br>consumption<br>Iat UN|Power<br>consumption<br>P at UN| |---|---|---|---|---|---|---| |V||V|V|V|mA|W| |110…125 AC/DC<br>230…240 AC|**3**.125|94|138|44|8(*)|1/1(*)<br>1.6/0.6(*)| ||**3**.240|184|264|72|6.5(*)|| (*) Rated coil consumption and power consumption values relate to UN = 125 and 240 V. The 38 Series interface modules (supply version 3) have built-in leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110…125) V AC and (230…240)V AC. This problem can occur, for example, when connecting the interface modules to PLC‚s with triac outputs or when connecting via relatively long cables. ## **Input specification - Solid State Relay types 38.31 and 38.41 - 14 mm wide** **Input data DC** ## **Input data AC/DC** |Nominal<br>voltage<br>UN|Supply<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Release<br>voltage<br>U|Rated coil<br>consumption<br>Iat UN|Power<br>consumption<br>P|Nominal<br>voltage<br>UN|Supply<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Release<br>voltage<br>U|Rated coil<br>consumption<br>Iat UN|Power<br>consumption<br>P| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |V||V|V|V|mA|W|V||V|V|V|mA|W| |12<br>24|**7**.012|9.6|18|5|9|0.2<br>0.3|24<br>**0**.024<br>16.8<br>30<br>9<br>16.5<br>0.3|**0**.024|16.8|30|9|16.5|0.3| ||**7**.024|16.8|30|5|12||||||||| **10** **38 SERIES** ## **Output specification - Solid State Relays** **L 34-1 - Output DC current v ambient temperature** 38.x1.x.xxx.9024 (only 38.81/91/21) **==> picture [197 x 126] intentionally omitted <==** **L 34 - Output AC current v ambient temperature** 38.x1.x.xxx.8240 (only 38.81/91/21) **==> picture [196 x 126] intentionally omitted <==** **B** **I:** SSR installed as a group (without gap between sockets) **II:** SSR installed individually in free air , or with a gap ≥ 9 mm, which implies a not significant influence from nearby components |**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle) at ambient temperature 50°C, single mounting (only 38.81/91/21)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle) at ambient temperature 50°C, single mounting (only 38.81/91/21)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle) at ambient temperature 50°C, single mounting (only 38.81/91/21)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle) at ambient temperature 50°C, single mounting (only 38.81/91/21)| |---|---|---|---| |Load|38.x1.x.xxx.**9024**|38.x1.x.xxx.**8240**|38.x1.x.xxx.**7048**| |24 V 6 A DC1|180 000|—|—| |24 V 3 A DC L/R = 10 ms|5000|—|—| |24 V 2 A DC L/R = 40 ms|3600|—|—| |24 V 1 A DC L/R = 40 ms|6500|—|—| |24 V 0.8 A DC L/R = 40 ms|9000|—|—| |24 V 1.5 A DC L/R = 80 ms|3250|—|—| |230 V 2 A AC1|—|60 000|—| |230 V 1.25 A AC15|—|3600|—| |48 V 0.1 A DC1|—|—|60 000| **11** **38 SERIES** ## **Additional technical data - Timed Interface Module** ## **EMC specifications** **B** |**Type of test**|||**Reference standard**|**Reference standard**| |---|---|---|---|---| |Electrostatic discharge|contact discharge||EN 61000-4-2|4 kV| ||air discharge||EN 61000-4-2|8 kV| |Radio-frequencyelectromagnetic field (80 ÷|1000 MHz)||EN 61000-4-3|10 V/m| |Fast transients (burst) (5-50 ns, 5 kHz) on Supplyterminals|||EN 61000-4-4|4 kV| |Surges (1.2/50 µs) on Supply terminals|common mode||EN 61000-4-5|4 kV| ||differential mode||EN 61000-4-5|4 kV| |Radio-frequencycommon mode (0.15 ÷ 80 MHz) on Supplyterminals|||EN 61000-4-6|10 V| |Radiated and conducted emission|||EN 55022|class B| |**Other data**|||**EMR**|**SSR**| |Power lost to the environment|without contact current|W|0.1|0.1| ||with rated current|W|0.6|0.5| |**Terminals**|||**38.21**|| |Wire striplength||mm <br>|10<br>|| |Screw torque||Nm|0.5|| |Max. wire size|||solid cable|stranded cable| |||mm2|1 x 2.5 / 2 x 1.5|1 x 2.5 / 2 x 1.5| |||AWG|1 x 14 / 2 x 16|1 x 14 / 2 x 16| ## **Times scales** (0.1…3)s (3…60)s (1…20)min (0.3…6)h ## **Functions** ||LED|Supply voltage|NO contact/output| |---|---|---|---| |||OFF|Open| |||ON|Open (time in progress)| |||ON|Closed| **Wiring diagram U** = Supply voltage = Output contact **(AI) On-delay.** Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. **(DI) Interval.** Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. **(GI) Pulse delayed.** Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs after a fixed time of 0.5 s. **(SW) Symmetrical flasher (starting pulse on). Symmetrical flasher (starting pulse on).** Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs after a fixed time of 0.5 s. **(SW) Symmetrical flasher (starting pulse on). Symmetrical flasher (starting pulse on).** Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off). **12** **38 SERIES** **B** ## **Outline drawings** 38.21 38.51 / 38.51.3 38.81 / 38.81.3 Screw terminal **==> picture [176 x 197] intentionally omitted <==** 38.61 / 38.61.3 38.91 / 38.91.3 Screwless terminal **==> picture [152 x 209] intentionally omitted <==** 38.01 38.31 38.52 Screw terminal **==> picture [180 x 202] intentionally omitted <==** 38.11 38.41 38.62 Screwless terminal **==> picture [179 x 205] intentionally omitted <==** **13** **38 SERIES** ## **Electromechanical Relay & Socket Combinations** **==> picture [517 x 725] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||| |---|---|---|---|---|---|---|---| |Screw terminal - 1 Pole relay 6 A| |Interface Module Code|Coil voltage|Relay|Socket| |38.51.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.01.0.024| |38.51.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.01.0.024| |38.51.0.048.0060|48 V AC/DC|34.51.7.048.0010|93.01.0.060| |38.51.0.060.0060|60 V AC/DC|34.51.7.060.0010|93.01.0.060| |93.01|38.51.0.125.0060|a|(110…125)V AC/DC|34.51.7.060.0010|93.01.0.125| |Hf.|38.51.0.240.0060|eS|(220…240)V AC/DC|34.51.7.060.0010|93.01.0.240| |38.51.3.125.0060|(110…125)V AC/DC|34.51.7.060.0010|93.01.3.125| |38.51.3.240.0060|_—_——|(230…240)V AC|34.51.7.060.0010|93.01.3.240| |38.51.7.006.0050|6 V DC|34.51.7.005.0010|93.01.7.024| |38.51.7.012.0050|———————|12 V DC|34.51.7.012.0010|93.01.7.024| |38.51.7.024.0050|24 V DC|34.51.7.024.0010|93.01.7.024| |38.51.7.048.0050|48 V DC|34.51.7.048.0010|93.01.7.060| |38.51.7.060.0050|60 V DC|34.51.7.060.0010|93.01.7.060| |38.51.8.240.0060|es|(230…240)V AC|34.51.7.060.0010|93.01.8.240| |#|93.51|Screwless terminal - 1 Pole rela|—|y 6 A| |Interface Module Code|Coil voltage|ee|Relay|Socket| |38.61.0.012.0060|———|12 V AC/DC|34.51.7.012.0010|93.51.0.024| |38.61.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.51.0.024| |38.61.0.125.0060|eT|(110…125)V AC/DC|34.51.7.060.0010|93.51.0.125| |38.61.0.240.0060|(220…240)V AC/DC|34.51.7.060.0010|93.51.0.240| |38.61.3.125.0060|(110…125)V AC/DC|34.51.7.060.0010|93.51.3.125| |38.61.3.240.0060|(230…240)V AC|34.51.7.060.0010|93.51.3.240| |38.61.7.012.0050|12 V DC|34.51.7.012.0010|93.51.7.024| |38.61.7.024.0050|a|24 V DC|34.51.7.024.0010|93.51.7.024| |38.61.8.240.0060|(230…240)V AC|34.51.7.060.0010|93.51.8.240| |aa|93.02|’|Screw terminal - 1 Pole relay 16 A|————————| |Interface Module Code|Coil voltage|7|Relay|Socket| |38.01.7.012.0050|es|12 V DC|41.61.9.012.0010|93.02.7.024| |38.01.7.024.0050|24 V DC|41.61.9.024.0010|93.02.7.024| |38.01.7.060.0050|eT|60 V DC|41.61.9.060.0010|93.02.7.060| |38.01.0.024.0060|24 V AC/DC|41.61.9.024.0010|93.02.0.024| |38.01.0.060.0060|60 V AC/DC|41.61.9.060.0010|93.02.0.060| |38.01.0.125.0060|125 V AC/DC|41.61.9.110.0010|93.02.0.125| |38.01.0.240.0060|240 V AC/DC|41.61.9.110.0010|93.02.0.240| |38.01.8.230.0060|230 V AC|41.61.9.110.0010|93.02.8.230| |es| |Screwless terminal - 1 Pole relay 16 A| |gh|93.52|Interface Module Code|en|Coil voltage|_—|Relay|Socket| |38.11.7.012.0050|Ss|12 V DC|41.61.9.012.0010|93.52.7.024| |Approvals| |38.11.7.024.0050|24 V DC|41.61.9.024.0010|93.52.7.024| |(according to type):| |38.11.7.060.0050|60 V DC|41.61.9.060.0010|93.52.7.060| |ceCH|S|38.11.0.024.0060|eS[_|24 V AC/DC|41.61.9.024.0010|93.52.0.024| |38.11.0.060.0060|60 V AC/DC|41.61.9.060.0010|93.52.0.060| |2|Ae|38.11.0.125.0060|es|125 V AC/DC|41.61.9.110.0010|93.52.0.125| |38.11.0.240.0060|240 V AC/DC|41.61.9.110.0010|93.52.0.240| |Certain relay/socket| |combinations|38.11.8.230.0060|230 V AC|41.61.9.110.0010|93.52.8.230| |Screw terminal - 2 Pole relay 8 A| |Interface Module Code|ee|Coil voltage|Relay|Socket| |38.52.0.024.0060|24 V AC/DC|41.52.9.024.0010|93.02.0.024| |38.52.0.060.0060|60 V AC/DC|41.52.9.060.0010|93.02.0.060| |—|38.52.0.125.0060|eS|(110…125)V AC/DC|41.52.9.110.0010|93.02.0.125| |—_———<$=———|38.52.0.240.0060|(220…240)V AC/DC|41.52.9.110.0010|93.02.0.240| |38.52.7.012.0050|12 V DC|41.52.9.012.0010|93.02.7.024| |38.52.7.024.0050|24 V DC|41.52.9.024.0010|93.02.7.024| |38.52.7.060.0050|60 V DC|41.52.9.060.0010|93.02.7.060| |a|————| |38.52.8.230.0060|(230…240)V AC|41.52.9.110.0010|93.02.8.230| |Screwless terminal - 2 Pole relay 8 A| |Interface Module Code|Coil voltage|Relay|Socket| |38.62.0.024.0060|24 V AC/DC|41.52.9.024.0010|93.52.0.024| |38.62.0.060.0060|60 V AC/DC|41.52.9.060.0010|93.52.0.060| |38.62.0.125.0060|(110…125)V AC/DC|41.52.9.110.0010|93.52.0.125| |38.62.0.240.0060|(220…240)V AC/DC|41.52.9.110.0010|93.52.0.240| |38.62.7.012.0050|12 V DC|41.52.9.012.0010|93.52.7.024| |———| |38.62.7.024.0050|ST|24 V DC|41.52.9.024.0010|93.52.7.024| |38.62.7.060.0050|60 V DC|41.52.9.060.0010|93.52.7.060| |38.62.8.230.0060|ee|(230…240)V AC|41.52.9.110.0010|93.52.8.230| **----- End of picture text -----**<br> **B 93.01** Hf. , # **93.51** aa **93.02** ’ gh **93.52** Approvals (according to type): ceCH S **14** **93 SERIES** Sockets and accessories for 38 series ns? --- **38** **SERIES** ## **Solid State Relay & Socket Combinations - 6.2 mm wide** **93.01** | } **93.51** Approvals (according to type): @ HAL & ® cA Yys Certain relay/socket combinations **==> picture [350 x 226] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Screw terminal| |Interface Module Code|Input voltage|Relay|Socket| |38.81.7.006.xxxx|ee|6 V DC|34.81.7.005.xxxx|93.01.7.024| |38.81.7.024.xxxx|24 V DC|34.81.7.024.xxxx|93.01.7.024| |38.81.7.060.xxxx|ee|60 V DC|34.81.7.060.xxxx|93.01.7.060| |38.81.0.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.01.0.125| |a| |38.81.0.240.xxxx|a|(220…240)V AC/DC|34.81.7.060.xxxx|93.01.0.240| |38.81.3.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.01.3.125| |38.81.3.240.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.01.3.240| |Screwless terminal| |Interface Module Code|es|Input voltage|Relay|Socket| |38.91.7.006.xxxx|esa|6 V DC|34.81.7.005.xxxx|93.51.7.024| |38.91.7.024.xxxx|ee|24 V DC|34.81.7.024.xxxx|93.51.7.024| |38.91.7.060.xxxx|ee|60 V DC|34.81.7.060.xxxx|93.51.7.060| |38.91.0.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.51.0.125| |38.91.0.240.xxxx|ee|(220…240)V AC/DC|34.81.7.060.xxxx|93.51.0.240| |38.91.3.125.xxxx|(110…125)V AC/DC|34.81.7.060.xxxx|93.51.3.125| |38.91.3.240.xxxx|(230…240)V AC|34.81.7.060.xxxx|93.51.3.240| |Example: .xxxx| |Po| **----- End of picture text -----**<br> Example: .xxxx .9024 .7048 .8240 **B** **==> picture [445 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Solid State Relay & Socket Combinations - 14 mm wide| |Screw terminal| |Interface Module Code|Input voltage|Relay|Socket| |38.31.0.024.xxxx|24 V AC/DC|41.81.7.024.xxxx|93.02.0.024| |38.31.7.012.xxxx|12 V DC|41.81.7.012.xxxx|93.02.7.024| |38.31.7.024.xxxx|24 V DC|41.81.7.024.xxxx|93.02.7.024| |.|—_—S_——| |Screwless terminal| |93.52|Interface Module Code|Input voltage|Relay|Socket| |Approvals|38.41.0.024.xxxx|24 V AC/DC|41.81.7.024.xxxx|93.52.0.024| |(according to type):|38.41.7.012.xxxx|12 V DC|41.81.7.012.xxxx|93.52.7.024| |38.41.7.024.xxxx|24 V DC|41.81.7.024.xxxx|93.52.7.024| **----- End of picture text -----**<br> **==> picture [508 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||| |---|---|---|---|---|---| |SSR / EMR & Timer Socket Combinations| |Screw terminal| |2|.~———|Interface Module Code|Input / Coil voltage|Relay|Socket| |38.21.0.012.0060|12 V AC/DC|34.51.7.012.0010|93.21.0.024| |38.21.0.024.0060|24 V AC/DC|34.51.7.024.0010|93.21.0.024| |38.21.0.024.xxxx|24 V AC/DC|34.81.7.024.xxxx|93.21.0.024| |93.21| |Approvals| |(according to type):| **----- End of picture text -----**<br> **15** **==> picture [24 x 24] intentionally omitted <==** **----- Start of picture text -----**<br> 38<br>SERIES<br>**----- End of picture text -----**<br> **==> picture [500 x 478] intentionally omitted <==** **----- Start of picture text -----**<br> Accessories<br>20-way jumper link for 38.21/51/61/81/91 093.20 (blue) 093.20.0 (black) 093.20.1 (red)<br>Rated values 36 A - 250 V<br>“ ZB a 1215 28<br>f oe<br>OTTooo ooo} e<br>093.20 es} UUUUUUUUUUUUUUUUUUUU<br>B<br>Approvals<br>185 62 62 62 62 62 62 62 62 62 62 1.85<br>(according to type):<br>@ EAL cAXus®<br>8-way jumper link for 38.01/11/31/41/52/62 093.08 (blue) 093.08.0 (black) 093.08.1 (red)<br>Rated values 10 A - 250 V<br>SES eS e e te ote = 10°<br>093.08 iF < 95.4 29<br>= ee eeaa st<br>bV U YU YU YU Yu UY Ute<br>Approvals (according to type): \¢——12.7 + 414 - 414 » 1414 |s_14 + |+_14 > |«_>|12.7 o. s e<br>EAL cs®<br>Plastic separator 093.01<br>Thickness 2 mm, required at the start and the end of a group of interfaces.<br>i Can be used for visual separation group, must be used for: |<br>- protective separation of different voltages of neighbouring PLC interfaces according to VDE 0106-101<br>- protection of cut jumper links<br>093.01<br>Sheet of marker tags for 38.21/51/61/81/91, plastic, 48 tags, 6 x 10 mm 093.48<br>HHaeSrorer:<br>aaae<br>& - & &<br>be fae te<br>“EEL<br>093.48<br>Sheet of marker tags (CEMBRE Thermal transfer printers) for 38.01/11/31/41/52/62 types<br>&=pepeL:tf ee 060.48<br>tH= &t- t& =+ (48 tags), 6 x 12 mm<br>Bok<br>“PFE<br>060.48<br>E<br>E<br>A<br>A<br>P<br>P<br>P A T E N T<br>P A T E N T<br>N<br>N<br>O<br>O<br>R<br>R<br>U<br>U<br>E<br>E<br>E<br>E<br>U<br>U<br>R<br>R<br>N<br>N<br>O<br>O<br>P<br>P<br>A<br>A<br>E<br>E<br>**----- End of picture text -----**<br> **16**
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →