Image not available
Illustrative purposes only
3745040000
BATTERY CHARGER, SWITCH MODE, 264VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MASCOT
- Product type:
- SVHC: No SVHC (10-Jun-2022)
- Plug Type: -
- Product Range: 3745 Series
- Charge Current: 1.5A
- Output Voltage: 4.2V
- Supply Voltage: 264VAC
- Battery Size Code: -
- Battery Charger Type: Switch Mode
- No. of Cells Charged: 1 Cell
- Battery Technologies Supported: Li-Ion
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 42.67 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3745 LI** Max. 6,3W Charger for Li-ion batteries - switch mode 3845 LI: Std plug-in housing - 3-step adaptive charge control. - Charge adapts to battery pack type, which is automatically identified. - Order plugs (3845) and mains cord separately - Automatic battery temperature monitoring and thermal control to prevent charge of cold/warm batteries. - Universal input voltage. (90-264 VAC) **==> picture [31 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 3845 LI<br>**----- End of picture text -----**<br> - Wake up and low current start-up of deeply discharged batteries. - Error indication for reverse polarity, short circuit, charging battery packs with wrong number of cells and safety timer run-out. - Approvals: - Medically certified Safety: EN 60601-1 ed. 3.1 EMC: EN 60601-1-2 ed. 4 - UL approved For updates: see www.mascot.no ## TECHNICAL SPECIFICATIONS 3745 LI ## **GENERAL INPUT/OUTPUT** ## **SAFETY PROTECTION EMC** **==> picture [17 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> MEDICAL<br>**----- End of picture text -----**<br> **Protection: Insulation class: Insulation voltage Primary – secondary: Electrical safety std: • Medical:** Protected against reversed polarity and short circuit proof. Class II **Input voltage:** 90-264 VAC **Protection:** Protected against reversed **Line Frequency:** 47 – 63Hz polarity and short circuit **Switch frequency, approx.:** 55 kHz proof. **Leakage current from batt. Insulation class:** Class II **with mains switched off:** ≈ 0A **Insulation voltage Temperature range Primary – secondary:** 4000VAC / 5700VDC **• Operating:** -25 °C - +40 °C **Electrical safety std: • Storage:** -25 °C - +85 °C **• Medical:** EN/IEC/ANSI 60601-1 **Ripple:** < 100 mV p-p **• Household batt. charger:** EN/IEC 60335-1 and -2-29 **• A/V and Comm. tech:** EN/IEC/UL 62368-1 **Dimensions (L×W×H):** 115 × 56 × 35 mm Replaces IEC 60950-1 **Weight:** 175g and IEC 60065 **EMC standards • Generic:** EN 61000-6-1 and -3 **• Medical:** EN 60601-1-2 **• Household:** EN 55014-1 and -2 **• Information tech.:** EN 55022 and EN 55024 **• Multi media:** EN 55032 **Input terminals:** 2-pin IEC 60320/C8 **Output terminals:** Battery docking **IP-code:** 4X VERSIONS CHARGE CONTROL Step 0 Step 1 Step 2 Step 3 (yellow) (yellow) (Flash yellow) (green) Battery Pack Max outputpower (W) Low Current start-up for deeply discharged batt. Charge Current Charge Voltage Charge termination when Ich: Restart when Vbat CC 40mA±10mA < 25mA EasyPack S 1.9W 0.45A ±50mA when batt. < 3V or max. 1 hr. CC 55mA±15mA < 55mA EasyPack L 3.6W 0.85A ±0.1A when batt. < 3V or max. 1 hr. 4.2V ±0.05V < 4.1V±0.05V CC 125mA±30mA < 125mA EasyPack XL 6.3W 1.5A ±0.15A when batt. < 3V or max. 1 hr. EasyPack CC 200mA±50mA < 260mA 6.3W 1.5A ±0.15A PLUS when batt. < 3V or max. 1 hr. ~~SS=S0=m~~ **TS300819 Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no** ## Charging characteristics and LED indication * **==> picture [430 x 310] intentionally omitted <==** **----- Start of picture text -----**<br> INDICATOR:<br>INDICATOR: YELLOW INDICATOR: GREEN<br>FLASHING YELLOW<br>Charge Voltage Battery Voltage<br>No voltage,<br>Battery Voltage no current<br>from charger!<br>Charge Current<br>Start Current Cut-Off Current No current (0A)<br>Low Current Start-Up at Vbatt <3V/cell<br>Error Mode if <3V/cell after 10 minutes<br>Step 0 Step 1 Step 2 Step 3<br>TTT Start Timer(10 min) CC Charge CV Charge (max1 h) Charge complete<br>Safety Timer (72 hours)<br>EE ———————<br>**----- End of picture text -----**<br> - _an animated video of this charging progress is available on our website_ ## BATTERY NOT CONNECTED INDICATIONS Battery not connected is indicated by FLASHING GREEN. In this mode charger will apply short pulses attempting to wake up deeply discharged batteries. ## ERROR INDICATIONS 2 red blinks: Battery is connected to charger with wrong polarity! 3 red blinks: Charger output is shorted. Check output cable connection! 4 red blinks: Battery voltage is low. Check battery status or voltage. 5 red blinks: Safety timer has run out. Check battery status or capacity. LED off: Battery voltage is too high. Check battery voltage. ## WAIT MODE INDICATIONS Yellow with 1 red blink: Battery temperature is too low (<0°C) Yellow with 2 red blink: Battery temperature is too high (>45°C) **TS300819** **Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no**
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →