Image not available
Illustrative purposes only
3600-P10-SI-4A
Thermal Magnetic Circuit Breaker, IP40, IP00, 3600 Series, 4 A, 1 Pole, 65 V, 240 V, Plug In
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ETA
- Product type: Thermal Magnetic Circuit Breakers
- SVHC: No SVHC (17-Jan-2022)
- No. of Poles: 1 Pole
- Product Range: 3600 Series
- Current Rating: 4A
- Voltage Rating VAC: 240V
- Voltage Rating VDC: 65V
- Circuit Breaker Mounting: Plug In
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 65.51 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Thermal-Magnetic Circuit Breakers 3600/3900** ## **Description** Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Designed for plug-in mounting with E-T-A sockets 17-P10-Si, 23-P10-Si, 63-P10-Si; or panel mounting using E-T-A clips. Featuring an unprotected shunt tap terminal and optional auxiliary contacts. Type 3900 offers lower internal resistance values and is fitted as standard with auxiliary contacts and an intermediate reset position in which all contacts are isolated. Approved to CBE standard EN 60934 (IEC 60934). ## **Typical applications** ~~LP~~ Process control systems, instrumentation, communications systems, rail vehicles. enema **3600 3900** standard type low-resistance type ## **Technical data** ## **Ordering information** ||**Terminal design**<br>**P10**blade terminals 6.3-0.8 (QC .250)<br>**Auxiliary contacts (3900: intermediate position as standard)**<br>**Si**<br>with blade terminals 6.3-08,one each NO/NC,<br>**Current ratings**<br>**0.05...16 A**(type 3600)<br>**0.05...10 A**(type 3900)|**Terminal design**<br>**P10**blade terminals 6.3-0.8 (QC .250)<br>**Auxiliary contacts (3900: intermediate position as standard)**<br>**Si**<br>with blade terminals 6.3-08,one each NO/NC,<br>**Current ratings**<br>**0.05...16 A**(type 3600)<br>**0.05...10 A**(type 3900)|**Terminal design**<br>**P10**blade terminals 6.3-0.8 (QC .250)<br>**Auxiliary contacts (3900: intermediate position as standard)**<br>**Si**<br>with blade terminals 6.3-08,one each NO/NC,<br>**Current ratings**<br>**0.05...16 A**(type 3600)<br>**0.05...10 A**(type 3900)|**Terminal design**<br>**P10**blade terminals 6.3-0.8 (QC .250)<br>**Auxiliary contacts (3900: intermediate position as standard)**<br>**Si**<br>with blade terminals 6.3-08,one each NO/NC,<br>**Current ratings**<br>**0.05...16 A**(type 3600)<br>**0.05...10 A**(type 3900)| |---|---|---|---|---| |||0.8 (QC .250)<br>**Auxiliary contacts (3900: intermediate position as standard)**<br>**Si**<br>with blade terminals 6.3-08,one each NO/NC,<br>**Current ratings**<br>**0.05...16 A**(type 3600)<br>**0.05...10 A**(type 3900)||| ||||**Current ratings**<br>**0.05...16 A**(type 3600)<br>**0.05...10 A**(type 3900)|| |||||| The exact part number required can be built up from the table of choices shown above. Ordering references for optional features should be omitted if not required. **Please be informed that we have minimum ordering quantities to be observed.** ## **Preferred types** |**Preferred types**|||||||| |---|---|---|---|---|---|---|---| |**Preferred types**|**Standard current ratings (A)**||||||| ||**0.5**|**1**|**2**|**4**|**8**|**10**|**16**| |3600-P10-Si-|x|x|x|x|x|x|x| |3900-P10-Si-|x|x|x|x|||| **Standard current ratings and typical internal resistance values** |**Current**<br>**ratings**<br>**(A)**<br>~~aS~~|**Internal resistance**<br>**(Ω)**<br>~~aS~~|**Internal resistance**<br>**(Ω)**<br>~~aS~~|**Current**<br>**ratings**<br>**(A)**|**Internal resistance**<br>**(Ω)**|**Internal resistance**<br>**(Ω)**| |---|---|---|---|---|---| ||**3600**<br>~~aS~~|**3900**<br>~~aS~~||**3600**|**3900**| |0.05<br>~~aS~~<br>~~ff~~|447<br>~~aS~~<br>~~ff~~|211<br>~~aS~~<br>~~ff~~|3<br>~~ff~~|0.19<br>~~ff~~|0.054<br>~~ff~~| |0.1<br>~~ff~~|131<br>~~ff~~|48<br>~~ff~~|4<br>~~ff~~|0.090<br>~~ff~~|0.035<br>~~ff~~| |0.2<br>~~ff~~<br>~~a~~|40<br>~~ff~~<br>~~a~~|12.4<br>~~ff~~<br>~~a~~|5<br>~~ff~~<br>~~a~~|0.061<br>~~ff~~<br>~~a~~|0.025<br>~~ff~~<br>~~a~~| |0.3|19.3|5.4|6|0.041|≤ 0.02| |0.4|10.4|3.1|7|0.034|≤ 0.02| |0.5|7.1|2.0|8|≤ 0.02|≤ 0.02| |0.6|4.3|1.32|10|≤ 0.02|≤ 0.02| |0.8<br>~~a~~|2.5<br>~~a~~|0.76<br>~~a~~|12<br>~~a~~|≤ 0.02<br>~~a~~|~~a~~| |1<br>~~a~~|1.67<br>~~a~~|0.49<br>~~a~~|14<br>~~a~~|≤ 0.02<br>~~a~~|~~a~~| |1.5|0.61|0.21|15|≤ 0.02|| |2<br>~~es~~|0.38|0.101|16|≤ 0.02|| |2.5<br>~~es~~|0.24|0.078|||| |**For further detailsplease see: htt**<br>Voltage rating|**lease see: http://www.e-t-a.de/ti_e **<br>AC 240 V, 50/60 Hz; DC 65 V<br>(UL: AC 250 V;DC 65 V)| |---|---| |Current rating range|3600: 0.05...16 A| ||3900: 0.05...10 A| |Auxiliary circuit|1 A, AC 240 V / DC 65 V| |Typical life<br>Ambient temperature -30...+60 °C|min. 10 V/10 mA<br>5,000 operations at 1 x IN, inductive<br>5,000 operations at 2 x IN,resistive<br>erature -30...+60 °C(-22...+140 °F)| |Insulation co-ordination rated impulse|Insulation co-ordination rated impulse<br>pollution| |(IEC 60664 and 60664 A) withstand voltage degree|(IEC 60664 and 60664 A) withstand voltage degree<br>2.5 kV<br>2<br>reinforced insulation in operatingarea| |Dielectric strength<br>(IEC 60664 and 60664A) test voltage|(IEC 60664 and 60664A) test voltage| |operating area|AC 3,000 V| |main/aux. circuit|AC 1,500 V| |aux. circuit 4-5/6-7<br>Insulation resistance|AC 840 V<br>>100 MΩ(DC 500 V)| |Interrupting capacity Icn|3600 3900<br>0.05...0.8 A 0.05...0.2 A self-limiting| ||1...2 A 0.3...2 A 200 A| ||2.5...16 A 2.5...10 A 400 A| |Interrupting capacity<br>(UL 1077)|IN<br>UN<br>0.05...16 A AC 250 V<br>1,000 A| |type 3600: 0.05...16 A DC 80 V|e 3600: 0.05...16 A DC 80 V<br>1,000 A| |Degree of protection<br>(IEC 60529/DIN 40050)terminal area IP00|operating area IP40<br>terminal area IP00| |Vibration<br>5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)<br>to IEC 60068-2-6, test Fc<br>10 frequencycycles/axis<br>Shock<br>25g (11 ms)to IEC 60068-2-27,test Ea<br>Corrosion<br>96 hours at 5 % salt mist<br>to IEC 60068-2-11,test Ka<br>Humidity<br>240 hours at 95 % RH<br>to IEC 60068-2-78,test Cab<br>~~ee~~<br>~~rr~~<br>~~SO~~|| |Mass|approx. 45g| **www.e-t-a.de** 1944 1 ## **Thermal-Magnetic Circuit Breakers 3600/3900** **==> picture [249 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions<br>**----- End of picture text -----**<br> **==> picture [249 x 325] intentionally omitted <==** **----- Start of picture text -----**<br> -P10-Si ø11.5<br>.453 ø6.5 ø8.5<br>.256 .335<br>ø4<br>.157<br>1 4 6 3 7 5 2<br>6.8<br>.268 blade terminals<br>6 x 6.8 = 40.8 DIN 46244-A6.3-0.8<br>6 x .268 = 1.61 (QC .250)<br>current rating in A 43<br>1.69<br>13 20<br>.512 .787<br>50<br>1.97<br>Terminal design -P10<br>1 3 2<br>OFF ON<br>11 .433<br>5 .197 2 .079<br>51 2.01<br>19 .748<br>10 .394<br>2<br>11.5 .453<br>8.5 .335<br>**----- End of picture text -----**<br> ## **Internal connection diagrams** **==> picture [249 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> with shunt terminal (standard)<br>and auxiliary contacts (-Si) only 3600<br>line 1 line 1 5 7<br>3 3 4 6<br>I > I ><br>3 (from IN=8 A) 3 (from IN=8 A)<br>2 2<br>**----- End of picture text -----**<br> ## **Installation drawing** **==> picture [249 x 182] intentionally omitted <==** **----- Start of picture text -----**<br> operating area<br>(reinforced insulation)<br>1 4 6 3 7 5 2<br>12.5<br>mounting area<br>.492<br>20 .787<br>38 1.50<br>2<br>.079<br>**----- End of picture text -----**<br> ## **Typical time/current characteristics** **==> picture [501 x 305] intentionally omitted <==** **----- Start of picture text -----**<br> 3600 0.05…7 A AC [1)] 3600 8…16 A AC [1)] 3900 0.05…10 A DC [2)]<br>10000 10000 10000<br>1000 1000 1000<br>100 100 100<br>10 10 10<br>1 1 1<br>0.1 0.1 0.1<br>0.01 0.01 0.01<br>0.001 0.001 0.001<br>1 2 4 6 8 10 20 40 60 80100 1 2 4 6 8 10 20 40 60 80100 1 2 4 6 8 10 20 40 60 80100<br>… times rated current … times rated current … times rated current<br>+140 °F +60 °C +73.4 °F+23 °C -22 °F -30 °C The time/current characteristic curve depends on the ambient temperature<br>prevailing. In order to eliminate nuisance tripping, please multiply the<br>circuit breaker current ratings by the derating factor shown below. See also<br>1) Magnetic tripping currents are increased by 20 % on DC supplies. section Technical information.<br>2) Magnetic tripping currents are decreased by 20 % on AC supplies. Ambient temp. °F -22 -4 +14 +32 +73.4 +104 +122 +140<br>°C -30 -20 -10 0 +23 +40 +50 +60<br>Derating factor 0.76 0.79 0.83 0.88 1 1.08 1.16 1.24<br>Trip time in seconds Trip time in seconds Trip time in seconds<br>**----- End of picture text -----**<br> > **1)** Magnetic tripping currents are increased by 20 % on DC supplies. > **2)** Magnetic tripping currents are decreased by 20 % on AC supplies. This is a metric design and millimeter dimensions take precedence ~~(~~[mm ] inch ~~)~~ **www.e-t-a.de** 1944 2 ## **Thermal-Magnetic Circuit Breakers 3600/3900** ## **Accessories** **Sockets 17-P10-Si 17-P10-Si-20025** (up to 16 A max. load) mounted with adapter Retaining clip Y 300 581 11 to special order. **Power-D-Box with sockets pre-wired 19BGT2 2U** for 18, 24 or 30 circuits. For technical data see product group Power Distribution Systems. **==> picture [232 x 341] intentionally omitted <==** **----- Start of picture text -----**<br> polarized blade terminal<br>slot fitting labels fromPhoenix, Weidmüller -P10 DIN 46244-A6.3-0.8 (QC .250)<br>retaining clip<br>6.3<br>depth .248<br>10 mm 10<br>(.394 in.) .394<br>1 2(k) 1 2(k)<br>11 12 11 12<br>23 242(i) 23 242(i)<br>a a 80 12.5<br>3.15 .492<br>symmetrical rail<br>EN 50022-35x7.5 G-profile<br>polarization recess adapter X20040901 EN 50035-G32<br>Sockets<br>17-P70-Si 17-P70-Si-20025<br>(up to 16 A max. load) mounted with adapter<br>Retaining clip Y 300 581 11 to special order.<br>blade terminal DIN 46244 part 2<br>slot fitting labels fromPhoenix, Weidmüller -P70 C profile (2xA2.8-0.8) (QC 2x.110)<br>retaining clip<br>2.8<br>depth .110 x<br>10 mm 10<br>(.394 in.) .394<br>1 2(k) 1 2(k)<br>11 12 11 12<br>23 242(i) 23 242(i)<br>80 12.5<br>e ee 3.15 .492<br>symmetrical rail<br>EN 50022-35x7.5 G-profile<br>polarization recess adapter X20040901 EN 50035-G32<br>10<br>8.5<br>25.8 33.3 1.4 5 41.3 45.8<br>6.5<br>10<br>8.5<br>25.8 33.3 1.4 5 41.3 45.8<br>6.5<br>.394<br>.335<br>1.02 1.31<br>.055 .197 1.63 1.80<br>.256<br>.394<br>.335<br>1.02 1.31<br>.055 .197 1.63 1.80<br>.256<br>**----- End of picture text -----**<br> ## **Module 17plus** ## **For technical data see section Power Distribution Systems** **Sockets 17-P70-Si 17-P70-Si-20025** (up to 16 A max. load) mounted with adapter Retaining clip Y 300 581 11 to special order. **==> picture [215 x 191] intentionally omitted <==** **----- Start of picture text -----**<br> slot for fitting labels from<br>Phoenix, Weidmüller, Wieland<br>]<br>17 plus<br>rT! u Ol<br>63 G-profile 6 25 25<br>e 115 EN 50035-G32 e max. 38<br>symmetrical rail<br>EN 50022-35x7,5<br>115,<br>51<br>47 425, 57<br>**----- End of picture text -----**<br> **==> picture [40 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> slot for busbar<br>**----- End of picture text -----**<br> **Sockets 23-P10-Si 63-P10-Si** (up to 16 A max. load) Retaining clip Y 300 581 03 to special order. > right-side terminal block (up to 16 A max. load) Retaining clip Y 300 581 03 to special order. test socket left-side terminal block module 7.4 7.4 .291 4.4 .291 12.5 .173 .492 **Approvals Authority Standard Voltage ratings Current ratings 3600:** 12.5 50 VDE IEC/EN 60934 AC 240 V 0.05...16 A .492 25 12.5 1.97 DC 65 V 0.05...16 A .984 polarized.492 75 UL UL 1077 AC 250 V 0.05...16 A recess 2.95 DC 80 V 0.05...16 A CSA C22.2 No. 235 AC 250 V 0.05...16 A DC 80 V 0.05...16 A **3900:** VDE IEC/EN 60934 AC 240 V 0.05...10 A DC 65 V 0.05...10 A ~~es =~~ 1944 **www.e-t-a.de** **==> picture [231 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> polarized blade terminals<br>DIN 46244-A6.3-0.8 (QC .250) 22.2 retainingclip<br>7.4 7.4 .874 21<br>.291 4.4 .291 12.5 6.25 .827 10<br>.173 .492 .246 .394<br>12.5 50 2<br>.492 25 12.5 1.97 4.4 6 .079<br>.984 .492 .173 .236<br>polarized.492 75 max. 30<br>recess 2.95 max. 1.18<br>6.8<br>64 50 57.4 64 50 57.4<br>6 x 6.8 = 40.8 6 x .268 = 1.61<br>3.5<br>.268<br>2.52 1.97 2.26 2.52 1.97 2.26<br>.138<br>**----- End of picture text -----**<br> 3 **Thermal-Magnetic Circuit Breakers 3600/3900** ## **Accessories** **==> picture [232 x 315] intentionally omitted <==** **----- Start of picture text -----**<br> Bus bar (10-way) (supplied as a complete package)<br>for socket 17 (for max. 100 A continuous load)<br>X 211 157 01 with terminal<br>X 211 157 02 without terminal<br>(more positions available on request)<br>Phoenix terminal AKG 35 cylinder head screw washer<br>max.cross section 35 mm [2] (AWG 2) M4x4 ISO1207 A 4.3 DIN 125<br>nickel plated nickel plated<br>female<br>connector<br>M4 Cu rail, tin-plated<br>7 12.8<br>.276 .504 pressure-relief joint<br>154.8 (1.1 mm (.043 in.)<br>6.09 thick constriction)<br>Insulate sleeving for bus bar<br>Y 303 824 01<br>9<br>.354 5.4 125<br>.213 4.92<br>Connector bus links -P10<br>X 210 588 01/ 1.5 mm [2] (AWG 16), brown up to 13 A max. load<br>X 210 588 02/ 2.5 mm [2] (AWG 14), black up to 20 A max. load<br>X 210 588 03/ 2.5 mm [2] (AWG 14), red up to 20 A max. load<br>X 210 588 04/ 2.5 mm [2] (AWG 14), blue up to 20 A max. load<br>2<br>.079<br>10 .394<br>17 .669<br>**----- End of picture text -----**<br> **==> picture [228 x 345] intentionally omitted <==** **----- Start of picture text -----**<br> 100 quick-connect tabs 6.3 (.250)<br>DIN 46247 tinned brass,<br>insulated<br>Extraction tool<br>Y 301 398 02<br>56<br>2.21<br>Mounting clip Installation drawing with<br>Y 300 504 02 mounting clips Y 300 504 02<br>(2 pcs needed per unit)<br>1<br>.039<br>0.5<br>.020<br>12.5 8.5<br>.492 60.4 .335<br>7.3 2.38<br>.287 50<br>1.97<br>M4<br>16.5 20<br>.650 .787<br>~70 ~2.76<br>46 1.81<br>1.9 .075 7.5 .295 2 .079<br>2 .079<br>8<br>.315<br>**----- End of picture text -----**<br> This is a metric design and millimeter dimensions take precedence ~~(~~[mm ] inch ~~)~~ All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. **www.e-t-a.de** 1944 4
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →