Image not available
Illustrative purposes only
3546165000
BATTERY CHARGER, SM, 4-CELL, 1.6A, 264V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MASCOT
- Product type:
- SVHC: No SVHC (10-Jun-2022)
- Plug Type: Mains Plug Sold Separately
- Product Range: 3546 Series
- Charge Current: 1.65A
- Output Voltage: 16.8V
- Supply Voltage: 264VAC
- Battery Size Code: -
- Battery Charger Type: Switch Mode
- No. of Cells Charged: 4 Cells
- Battery Technologies Supported: Li-Ion
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 44.78 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3546 LI** Max. 28W Charger for Li-ion batteries - switch mode - 3-step charge control with current detection - Universal input voltage (90-264 VAC) - Wake up and low current start-up of deeply discharged batteries - Error indication for reverse polarity, short circuit, charging battery packs with wrong number of cells and safety timer run-out - With NTC input on request - Order plugs and mains cord separately - ECO-design compliance: - DoE and CEC - Approvals: - Medically certified Safety: EN 60601-1 ed. 3.1 EMC: EN 60601-1-2 ed. 4 - UL approved For updates: see www.mascot.no ## TECHNICAL SPECIFICATIONS **==> picture [17 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> MEDICAL<br>**----- End of picture text -----**<br> ## **GENERAL INPUT/OUTPUT** ## **SAFETY PROTECTION EMC** **Input voltage:** 90-264 VAC **Line Frequency:** 47 – 63Hz **Switch frequency, approx.:** 40 kHz **Leakage current from batt. with mains switched off:** <0,4mA @ nominal battery voltage **Temperature range • Operating:** -25 °C - +40 °C **• Storage:** -25 °C - +85 °C **Ripple:** < 100 mV p-p **Dimensions (L×W×H):** 124 × 50 × 37 mm **Weight:** 220g **Protection:** Protected against reversed polarity and short circuit proof Class II **Insulation class:** Class II **Insulation voltage Primary – secondary:** 4000VAC / 5700VDC **Electrical safety std:** EN/IEC 60335-2-29, EN/IEC 60335-2-29, EN/IEC/ANSI 60601-1 **EMC standards • Medical • Emission • Immunity Input terminal: Output terminals:** EN 60601-1-2 EN 55014-1, EN 61000-6-3 EN 55014-2, EN 61000-6-1 2-pin IEC 60320 connector C8 DC connector, battery clips, push on terminals or open ends 4X **IP-code:** ## VERSIONS |CHARGE CONTROL<br>~~ee~~<br>~~|~~|CHARGE CONTROL<br>~~ee~~<br>~~|~~|Step 0 < 10min<br>(yellow)<br>~~ee~~<br>|Step 0 > 10min<br>(Red: 4 blinks)<br>~~es~~|Step 1<br>(yellow)|Step 2<br>(Flash yellow)|Step 3<br>(green)<br>~~ee~~| |---|---|---|---|---|---|---| |Cells<br>~~ee~~<br>~~a~~<br>~~|~~<br>~~P|~~|Max output<br>power (W)<br>~~ee ~~<br>~~a~~<br>~~ft~~<br>~~P|~~|Low Current start-up for<br>deeply discharged batt.<br> ~~ee ~~<br>~~ee~~<br>~~ft~~<br>|Battery voltage too low<br> ~~es~~<br>~~ee~~<br>~~|~~|Charge Current<br>~~ee~~<br>~~||~~|Charge Voltage<br>~~ee~~<br>~~|~~|Charge term<br>when current is:<br>~~ee~~<br>~~ee~~| |2<br>~~| ~~<br>~~P|~~<br>~~|~~|23W<br> ~~ft~~<br>~~P|ft~~<br>|CC 100mA±25mA<br>when batt. < 6V<br>~~ft~~<br>~~ft~~<br>|0A/0V<br>~~|~~<br>~~|~~<br>~~|~~<br>~~**|**~~|2.5A ±0.3A<br>~~||~~<br>~~||~~|8.4V ±0.1V<br>~~|~~<br>~~|~~|< 100mA<br>or max. 1 hr.<br>~~ee~~| |3<br> <br>~~P|~~<br>~~|~~<br>~~P|~~|28W<br> ~~ft~~<br>~~P|ft~~<br>~~|~~<br>~~P|~~|CC 100mA±25mA<br>when batt. < 9V<br>~~ft~~<br>~~ft~~<br>~~|~~<br>||2.2A ±0.2A<br>~~||~~<br>~~||~~<br>~~||~~|12.6V ±0.1V<br>~~|~~<br>~~|~~<br>~~|~~|| |4<br> <br>~~P|~~<br>~~| ~~<br>~~P|~~<br>~~||~~|28W<br> ~~ft~~<br>~~P| ft~~<br> ~~|~~<br>~~P|ft~~<br>~~||~~|CC 100mA±25mA<br>when batt. < 12V<br>~~ft~~<br>~~ft~~<br>~~|~~<br>~~ft~~<br>||1.6A ±0.15A<br>~~| |~~<br>~~| |~~<br>~~||~~<br>~~**|**~~|16.8V ±0.1V<br>~~|~~<br>~~|~~<br>~~|~~|| |7<br> <br>~~P|~~<br>~~||~~|29W<br> ~~|~~<br>~~P|ft~~<br>~~|||~~|CC 100mA±25mA<br>when batt. < 21V<br>~~|~~<br>~~ft~~<br>~~|~~||1.0A ±0.1A<br>~~||~~<br>~~**|**~~<br>~~|~~|29.4V ±0.2V<br>~~|~~<br>~~|~~|| |10<br> <br>~~P|~~<br>~~||~~|29W<br> ~~|~~<br>~~P| ft~~<br>~~|||~~|CC 100mA±25mA<br>when batt. < 30V<br>~~|~~<br>~~ft~~<br>~~|~~||0.7A ±0.07A<br>~~| |~~<br>~~**|**~~<br>~~|~~|42V ±0.3V<br>~~|~~<br>~~|~~|| **TS170619** **Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no** ## Charging characteristics and LED indication * **==> picture [430 x 310] intentionally omitted <==** **----- Start of picture text -----**<br> INDICATOR:<br>INDICATOR: YELLOW INDICATOR: GREEN<br>FLASHING YELLOW<br>Charge Voltage Battery Voltage<br>No voltage,<br>Battery Voltage no current<br>from charger!<br>Charge Current<br>Start Current Cut-Off Current No current (0A)<br>Low Current Start-Up at Vbatt <3V/cell<br>Error Mode if <3V/cell after 10 minutes<br>Step 0 Step 1 Step 2 Step 3<br>TTT Start Timer(10 min) CC Charge CV Charge (max1 h) Charge complete<br>Safety Timer (72 hours)<br>EE ———————<br>**----- End of picture text -----**<br> - _an animated video of this charging progress is available on our website_ ## BATTERY NOT CONNECTED INDICATIONS Battery not connected is indicated by FLASHING GREEN. In this mode charger will apply short pulses attempting to wake up deeply discharged batteries. ## ERROR INDICATIONS 2 red blinks: Battery is connected to charger with wrong polarity! 3 red blinks: Charger output is shorted. Check output cable connection! 4 red blinks: Battery voltage is low. Check battery status or voltage. 5 red blinks: Safety timer has run out. Check battery status or capacity. LED off: Battery voltage is too high. Check battery voltage. ## WAIT MODE INDICATIONS Yellow with 1 red blink: Battery temperature is too low (<0°C) Yellow with 2 red blink: Battery temperature is too high (>45°C) **TS170619** **Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no** ## Exchangeable AC plugs **EU plug adapter US plug adapter** Part no. 127000 Part no. 127100 Weight: 20,9 g Weight: 13,4 g fib fH = ‘ — — ‘fl ib **UK plug adapter AUS plug adapter** Part no. 127200 Part no. 127300 Weight: 29,2 g Weight: 21,4 g **2-pin IEC 60320 C7 mains cord** 1800 mm EU part no. 131306, UK part no. 131148, US part no. 131368, AU part no. 013108 |, ae 124 mm 50mm 37mm **TS170619** **Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no**
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →