Image not available
Illustrative purposes only
3540120000
Battery Charger, Desktop, Lead Acid, 264 V, 12 VDC Output, 20A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MASCOT
- Product type:
- SVHC: No SVHC (10-Jun-2022)
- Plug Type: IEC 60320 C8
- Product Range: 3540 Series
- Charge Current: 20A
- Output Voltage: 12V
- Supply Voltage: 264VAC
- Battery Size Code: -
- Battery Charger Type: Desktop
- No. of Cells Charged: -
- Battery Technologies Supported: Lead Acid
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 245.49 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3540 LA** Max. 294W Charger for Lead Acid batteries - 3-step charge control with current detection - XLR output plug for wheelchairs and scooters available - Input voltage 198-264 VAC - Wake up and low current start-up of deeply discharged batteries - Error indication for reverse polarity, charging of wrong lower voltage battery pack, defect battery and safety timer run-out - Fixed mains cable, 2-pin IEC 60320 available - Mounting bracket included - ECO-design compliance: DoE and CEC - Custom specifications on request - Approvals: - Home healthcare EN 60601-1-11 (fixed cord versions only) - Medically certified: Safety: EN 60601-1 ed. 3.1 EMC: EN 60601-1-2 ed. 4 (24V) - UL approved For updates: see www.mascot.no ## TECHNICAL SPECIFICATIONS **==> picture [17 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> MEDICAL<br>**----- End of picture text -----**<br> ## **GENERAL INPUT/OUTPUT** ## **SAFETY PROTECTION EMC** 198-264 VAC 47 – 50Hz 65 kHz **Input voltage:** 198-264 VAC **Line Frequency:** 47 – 50Hz **Switch frequency, approx.:** 65 kHz **Leakage current from batt. with mains switched off:** <130μA @ 24V **Temperature range** • **Operating:** -25 °C - +40 °C -25 °C - +40 °C -25 °C - +65 °C • **Storage:** -25 °C - +65 °C **Temp. compensation of charge voltage** -3 to -4mV/°C pr. cell (w. batt. clips only) **Ripple:** < 100 mV p-p **Dimensions (L×W×H):** 210 × 113 × 53 mm **Weight:** With mains cable 1400g With IEC60320 1150g **Protection:** **Insulation class: Insulation voltage Primary – secondary: Electrical safety std: EMC standards Input terminal:** **Output terminals:** **IP-code:** Protected against reversed polarity, short circuit proof and thermal run-off. Prevents sparking. Charge timer: 4h Safety timer: 72h Class II (Double insulated) 4000VAC / 5700VDC EN/IEC/ANSI 60601 EN 60601-1-2: 2015 (Edition 4) Fixed mains cable, 2-pin IEC 60320 available XLR plug or cord with insulated battery clips and temp. sensor IP44 (IP40 w IEC 60320) ## VERSIONS |Charge control (LED indication)|Charge control (LED indication)|Charge control (LED indication)|Charge control (LED indication)|Charge control (LED indication)|Charge control (LED indication)|Charge control (LED indication)|Charge control (LED indication)| |---|---|---|---|---|---|---|---| ||Step 0 < 30 min|Step 0 > 30 min|Step 1|Step 2|Step 3|Float charge|Restart| ||(Yellow)|(Red=error)|(Yellow)|(Flash Yellow)|(Green)||| |12V|2,4A ± 0,5A<br>(batt. volt< 10,5A)|< 0A|20A ± 0,3A<br>(batt. volt >10,5V)<br>(to Vbat = 14,7V)|14,7V ± 0,1V<br>(until I charge <2,4A or >4hr)<br>tapering charge current|13,7V +- 0,1V<br>(until I charge > 18A)<br>supply current up to max 20A<br>for possible parallel load|20V ± 0,1V<br>Pulsing curr. at safe float volt<br>level for max. topping of batt.<br>capacity|>18A or<br><13V<br>in 10 sec| |24V|1,4A ± 0,5A<br>(batt. volt< 21V)||10A ± 0,3A<br>(batt. volt >21V)<br>(to Vbat = 29,4V)|29,4V ± 0,2V<br>(until I charge <1,4A or >4hr)<br>tapering charge current|27,4V ± 0,1V<br>(until I charge > 8,5A)<br>supply current up to max 10A<br>for possible parallel load|27,4V ± 0,1V<br>Pulsing curr. at safe float volt<br>level for max. topping of batt.<br>capacity|>8,5A or<br><26V<br>in 10 sec| **TS140521** **Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no** ## Charging characteristics and LED indication **==> picture [451 x 331] intentionally omitted <==** **----- Start of picture text -----**<br> INDICATOR:<br>INDICATOR: YELLOW INDICATOR: GREEN<br>FLASHING YELLOW<br>TET<br>Charge Voltage<br>Charge Voltage<br>Battery Voltage<br>Pulse frequency: Microprocessor controlled..<br>Charge Current Pulse Current: max current<br>Start Current<br>Low Current Start-Up at Vbatt <10.5V<br>Error Mode if <10.5V after 30 minutes<br>(for 12V system)<br>(0.5 hours)Start TimerStep 0 Boost ChargeStep 1 Top Up Charge (4 hours)Step 2 Float ChargeStep 3<br>TTT<br>Safety Timer (72 hours)<br>es Gn<br>**----- End of picture text -----**<br> ## STEP 1 - BOOST CHARGE LED-indicator: YELLOW The charger is in constant current mode (CC), charging with the maximum **Yellow** [] current until battery voltage reach Top-Up level. STEP 2 – TOP-UP CHARGE The charger is in constant voltage mode. The LED-indication will be FLASHING YELLOW during Top-up charge. The charger stays in this mode until the charge current decreases to charge termination level or the Top-Up Charge Timer runs out. The battery is charged to its **Yellow** : ~~<~~ The charger is in constant voltage mode. The LED-indication will be FLASHING YELLOW during Top-up charge. The charger stays in this mode until the charge current decreases to charge termination level or the Top-Up Charge Timer runs out. The battery is charged to its full capacity at the end of this step ## STEP 3 – FLOAT CHARGE The LED-indication on the charger is GREEN and the battery is fully charged. The charger is in standby mode. The charge voltage is at standby level and the charger may remain connected to the battery. The charger will return to boost charge if the battery is used. A load larger than the cut-off current will initiate a new charge cycle. **==> picture [41 x 27] intentionally omitted <==** **----- Start of picture text -----**<br> Green<br>oT<br>**----- End of picture text -----**<br> ## BATTERY NOT CONNECTED Battery not connected is indicated by FLASHING GREEN. In this mode charger will apply short pulses attempting to wake up deeply discharged batteries. ## ERROR INDICATIONS - 2 red blinks: Battery is connected to charger with wrong polarity! - 4 red blinks: Charging of wrong lower voltage battery pack (e.g. 12V) will be limited to 1.4A and terminated after 30min - 5 red blinks: Safety timer has run out. Check battery status or capacity. - 6 red blinks: Defect battery LED off: Battery voltage is too high (>32V). Check battery voltage. **TS140521** **Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no** **==> picture [388 x 549] intentionally omitted <==** **----- Start of picture text -----**<br> 53 mm<br>|<br>© | \<br>113 mm<br>ks<br>210 mm<br>(& Y<br>53 mm<br>113 mm<br>210 mm<br>141,48 mm<br>70 mm<br>104 mm<br>140 mm<br>**----- End of picture text -----**<br> Mounting bracket, part no. 205800 **TS140521** **Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no**
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →