3031089
Standard Terminal Block, 1 Contacts, 4.2 mm, Terminal Block, DIN Rail, DIN Rail Mount, 16 AWG
- Manufacturer: PHOENIX CONTACT
- Product type:
- Product Range:-; No. of Contacts:1Contacts; Pitch Spacing:4.2mm; Connector Type:Terminal Block, DIN Rail; Connector Mounting:DIN Rail Mount; Wire Size AWG Max:16AWG; Wire Size AWG Min:28
- SVHC: No SVHC (04-Feb-2026)
- Pitch Spacing: 4.2mm
- Product Range: -
- Connector Type: Terminal Block, DIN Rail
- Contact Plating: -
- No. of Contacts: 1Contacts
- Contact Material: -
- Wire Size AWG Max: 16AWG
- Wire Size AWG Min: 28AWG
- Connector Mounting: DIN Rail Mount
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 1.1 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Spring Cage Feed-Through Terminal Blocks ST**
The product family **ST** with the new spring cage system **"mini spring"** is extremely space-saving. Space is saved thanks to a clearly smaller spring system without having to give up such familiar quality features as the large insertion space.
The outstanding feature of the feed-through terminals is their space-saving design, the generous labeling options and a flexible bridging system. The insertion space of the ST terminal blocks is designed in such a way that flexible conductors with the rated cross section with ferrule can also be wired up without difficulty.
The ground terminal blocks with the same shape as the feed-through terminal blocks make contact via simple snapping on the mounting rail and thus take over the ground conductor function. The housings are made of unbreakable polyamide 6.6 of the inflammability class V0 acc. to UL 94.
## **Marking**
A clear assignment of the connection lines is a preel or 4 requisite for unambiguous ~ J and correct installation of acd = i, terminal strips. The + " The ST series is ideally = > | “fle suited to these requirements. The generous labeling option using ZB standard Zack ("quick") strip in the terminal center is always easily accessible and readily recognizable, even when wired. Moreover, each termination point can also be labeled for special applications.
available in the number of position 2, 3, 4, 5 and 10. 20-pos. bridges can also be delivered for the 4, 5 and 6 mm terminal block pitches which can be cut to suit your requirements.
There is also the possibility of a practical test connection in the bridge shaft of the terminal block.
**Generous wire entrance** The ST series has large conductor openings, which eliminate the need to move up to a large terminal block when ferrules are required.
**Plug-in bridging system FBS** The ST terminal block has dual channels for handling all types of bridging =? possibilities. By means of a plug-in bridges the chain ay bridging can be achieved fe either with a 2-pos. standard aes jumper or with multi-position y.pa bridges. The multi-position version is especially useful for fast bridging of multi-position terminal strips. The bridging between non-adjacent terminals can also be handled with this version. The plug-in bridges are
Phoenix Contact GmbH & Co. KG • 32823 Blomberg, Germany Phone +49 52 35 3-00 • Fax +49 52 35 3-4 12 00 • www.phoenixcontact.com
**Feed-Through Terminal Block ST 1,5**
|(IEC)<br>rigid<br>flexible<br>[mm2]<br>solid<br>stranded|AWG|I<br>[A]|U<br>[V]|
|---|---|---|---|
|IEC 60 947-7-1<br>0.08-1.5<br>0.08-1.5|28-16|17.5|500|
|EN 50 019*<br>0.08-1.5<br>0.08-1.5|28-16|17.5|420|
|* EC Prototype certificate no.: KEMA 01ATEX2129U||||
|For information on installation and usage of accessories for EEx e applications,||||
|see www.clipline.phoenixcontact.com.||||
## u P F KEMA
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block**,<br>for mounting on3<br>gray<br>terminal width 4.2<br>blue<br>terminal width 4.2<br>orange<br>terminal width 4.2<br>red<br>terminal width 4.2<br>black<br>terminal width 4.2<br>**ST 1,5**<br>**30 31 07 6**<br>**50**<br>**ST 1,5 BU**<br>**30 31 08 9**<br>**50**<br>**ST 1,5 OG**<br>**30 37 01 2**<br>**50**<br>**ST 1,5 RD**<br>**30 37 03 8**<br>**50**<br>**ST 1,5 BK**<br>**30 37 06 7**<br>**50**<br>(1)**End cover**<br>gray<br>**D-ST 2,5**<br>**30 30 41 7**<br>**50**<br>(2)**Insulating stop sleeve,**prevents unintentional clamping<br>of the insulation in the case of smaller cross sections<br>Cross section range:<br>0.08-0.2 mm2<br>white<br>0.25-0.5 mm2<br>gray<br>**ISH 1,5/0,2**<br>**32 06 13 1**<br>**50**<br>**ISH 1,5/0,5**<br>**30 31 03 4**<br>**50**<br>(3)**Plug-in bridge,**for<br>2-pos.<br>cross-connections in the<br>3-pos.<br>terminal center<br>4-pos.<br>5-pos.<br>10-pos.<br>20-pos.<br>**FBS 2-4**<br> Imax.: 17.5 A<br>**30 30 11 6**<br>**50**<br>**FBS 3-4**<br>17.5 A<br>**30 30 12 9**<br>**50**<br>**FBS 4-4**<br>17.5 A<br>**30 30 13 2**<br>**50**<br>**FBS 5-4**<br>17.5 A<br>**30 30 14 5**<br>**50**<br>**FBS 10-4**<br>17.5 A<br>**30 30 15 8**<br>**10**<br>**FBS 20-4**<br>17.5 A<br>**30 30 35 2**<br>**10**<br>(4)**Partition plate,**for<br>visual and electrical separation<br>of terminal groups, 2 mm thick<br>**ATP-ST 4**<br>**30 30 72 1**<br>**50**<br>(5)**Test adapter,**for 4 mm∅test connector PS<br>and 4 mm∅safety test connectors,<br>making contact in the bridge shaft<br>**PAI 4**<br>**30 30 92 5**<br>**10**<br>(6)**Modular test connector**, for individual<br>assembly of test connector strips,<br>can be labeled with ZBF 4<br>**PS-4**<br>**30 30 97 0**<br>**10**<br>(7)**Warning cover,**for the<br>operating shafts of the “mini-spring”<br>ST spring cage terminal blocks<br>**WST 1,5**<br>**30 30 95 8**<br>**10**<br>(8)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 0 - 0,4 x 2,5**<br>**12 04 50 4**<br>**10**<br>(9)**Zack strip,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 4:UNPRINTED**<br>**08 08 58 7**<br>**10**<br>(10)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 4:UNPRINTED**<br>**08 05 00 1**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>4.2 / 48.5 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>36.5 / 44<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>17.5 / 1.5<br>Rated surge voltage / contamination class<br>[kV] / –<br>6 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 1.5<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 1.5<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>0.5<br>**Stripping length**<br>[mm]<br>10<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 1<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>–<br>CSA/CUL: [V] / [A] / AWG<br>–<br>S~~S~~<br>es<br>vy<br>mu<br>ey<br>[off]|**Order No.**<br>~~S~~|Pcs<br>.<br>Pkt.<br>~~S~~|
|---|---|---|
||**30 31 07 6**<br>**30 31 08 9**<br>**30 37 01 2**<br>**30 37 03 8**<br>**30 37 06 7**<br>~~S~~|**50**<br>**50**<br>**50**<br>**50**<br>**50**<br>~~S~~|
||**30 30 41 7**|**50**|
||**32 06 13 1**<br>**30 31 03 4**|**50**<br>**50**|
||**30 30 11 6**<br>**30 30 12 9**<br>**30 30 13 2**<br>**30 30 14 5**<br>**30 30 15 8**<br>**30 30 35 2**|**50**<br>**50**<br>**50**<br>**50**<br>**10**<br>**10**|
||**30 30 72 1**|**50**|
||**30 30 92 5**|**10**|
||**30 30 97 0**|**10**|
||**30 30 95 8**|**10**|
||**12 04 50 4**|**10**|
||**08 08 58 7**|**10**|
||**08 05 00 1**|**10**|
Phoenix Contact page 2 of 15
**Ground Terminal Block**
**ST 1,5-PE**
|(IEC)<br>rigid<br>flexible<br>[mm2]<br>solid<br>stranded|AWG|
|---|---|
|IEC 60 947-7-2<br>0.08-1.5<br>0.08-1.5|28-16|
|EN 50 019*<br>0.08-1.5<br>0.08-1.5|28-16|
|* EC Prototype certificate no.: KEMA 01ATEX2129U||
|For information on installation and usage of accessories for EEx e applications,||
|see www.clipline.phoenixcontact.com.||
Observe the current carrying capacity of mounting rails.
## u P F KEMA
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>green-yellow<br>terminal width 4.2<br>**ST 1,5-PE**<br>**30 31 51 3**<br>**50**<br>(1)**End cover**<br>gray<br>**D-ST 2,5**<br>**30 30 41 7**<br>**50**<br>(2)**Insulating stop sleeve,**prevents unintentional clamping<br>of the insulation in the case of smaller cross sections<br>Cross section range:<br>0.08-0.2 mm2<br>white<br>0.25-0.5 mm2<br>gray<br>**ISH 1,5/0,2**<br>**32 06 13 1**<br>**50**<br>**ISH 1,5/0,5**<br>**30 31 03 4**<br>**50**<br>(3)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 0 - 0,4 x 2,5**<br>**12 04 50 4**<br>**10**<br>(4)**Zack strip,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 4:UNPRINTED**<br>**08 08 58 7**<br>**10**<br>(5)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 4:UNPRINTED**<br>**08 05 00 1**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>4.2 / 48.5 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>36.5 / 44<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>–<br>Rated surge voltage / contamination class<br>[kV] / –<br>6 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 1.5<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 1.5<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>0.5<br>**Stripping length**<br>[mm]<br>10<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 1<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>–<br>CSA/CUL: [V] / [A] / AWG<br>–<br>ee~~l~~|**Order No.**<br>~~l~~|Pcs<br>.<br>Pkt.<br>~~l~~|
|---|---|---|
||**30 31 51 3**<br>~~l~~|**50**<br>~~l~~|
||**30 30 41 7**|**50**|
||**32 06 13 1**<br>**30 31 03 4**|**50**<br>**50**|
||**12 04 50 4**|**10**|
||**08 08 58 7**|**10**|
||**08 05 00 1**|**10**|
Phoenix Contact page 3 of 15
**Feed-Through Terminal Block ST 2,5**
|(IEC)<br>rigid<br>flexible<br>[mm2]<br>solid<br>stranded|AWG|I<br>[A]|U<br>[V]|
|---|---|---|---|
|IEC 60 947-7-1<br>0.08-4<br>0.08-2.5|28-12|31|800|
|EN 50 019*<br>0.08-4<br>0.08-2.5|28-12|25/21|550|
|* EC Prototype certificate no.: KEMA 00ATEX2052U||||
|For information on installation and usage of accessories for EEx e applications,|||For information on installation and usage of accessories for EEx e applications,|
|see www.clipline.phoenixcontact.com.||||
## u P F KEMA
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>gray<br>terminal width 5.2<br>blue<br>terminal width 5.2<br>orange<br>terminal width 5.2<br>red<br>terminal width 5.2<br>black<br>terminal width 5.2<br>**ST 2,5**<br>**30 31 21 2**<br>**50**<br>**ST 2,5 BU**<br>**30 31 22 5**<br>**50**<br>**ST 2,5 OG**<br>**30 37 07 0**<br>**50**<br>**ST 2,5 RD**<br>**30 37 09 6**<br>**50**<br>**ST 2,5 BK**<br>**30 37 12 2**<br>**50**<br>(1)**End cover**<br>gray<br>**D-ST 2,5**<br>**30 30 41 7**<br>**50**<br>(2)**Insulating stop sleeve,**prevents unintentional clamping<br>of the insulation in the case of smaller cross sections<br>Cross section range:<br>0.08-0.2 mm2<br>white<br>0.25-0.5 mm2<br>gray<br>0.75-1 mm2<br>black<br>**ISH 2,5/0,2**<br>**30 02 84 3**<br>**50**<br>**ISH 2,5/0,5**<br>**30 02 85 6**<br>**50**<br>**ISH 2,5/1**<br>**30 02 86 9**<br>**50**<br>(3)**Plug-in bridge,**for<br>2-pos.<br>cross-connections in the<br>3-pos.<br>terminal center<br>4-pos.<br>5-pos.<br>10-pos.<br>20-pos.<br>**FBS 2-5**<br> Imax.: 24 A<br>**30 30 16 1**<br>**50**<br>**FBS 3-5**<br>24 A<br>**30 30 17 4**<br>**50**<br>**FBS 4-5**<br>24 A<br>**30 30 18 7**<br>**50**<br>**FBS 5-5**<br>24 A<br>**30 30 19 0**<br>**50**<br>**FBS 10-5**<br>24 A<br>**30 30 21 3**<br>**10**<br>**FBS 20-5**<br>24 A<br>**30 30 22 6**<br>**10**<br>(4)**Partition plate,**for<br>visual and electrical separation<br>of terminal groups, 2 mm thick<br>**ATP-ST 4**<br>**30 30 72 1**<br>**50**<br>(5)**Test adapter,**for 4 mm∅test connector PS<br>and 4 mm∅safety test connectors,<br>making contact in the bridge shaft<br>**PAI 4**<br>**30 30 92 5**<br>**10**<br>(6)**2.3 mm**∅**test connector1)**, consisting of<br>metal part and red insulating sleeve<br>(7)**Modular test connector,**can be labeled with ZBF 5<br>**MPS-RD**<br>**02 01 55 3**<br>**10**<br>**PS 5**<br>**30 30 98 3**<br>**10**<br>(8)**Warning cover,**for the<br>operating shafts of the “mini-spring”<br>ST spring cage terminal blocks<br>**WST 2,5**<br>**30 30 94 1**<br>**10**<br>(9)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 1 - 0,6 x 3,5**<br>**12 04 51 7**<br>**10**<br>(10)**Zack strip,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 5 :UNPRINTED**<br>**08 08 64 2**<br>**10**<br>(11)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 5:UNPRINTED**<br>**10 50 00 4**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>5.2 / 48.5 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>36.5 / 44<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>31 / 4<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 2.5<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 2.5<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>0.5<br>**Stripping length**<br>[mm]<br>10<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 3<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>600 / 20 / 26 - 12<br>CSA/CUL: [V] / [A] / AWG<br>600 / 20 / 26 - 12<br>|<br>ry<br>wt<br>7<br>SSSe8|**Order No.**|Pcs<br>.<br>Pkt.|
|---|---|---|
||**30 31 21 2**<br>**30 31 22 5**<br>**30 37 07 0**<br>**30 37 09 6**<br>**30 37 12 2**|**50**<br>**50**<br>**50**<br>**50**<br>**50**|
||**30 30 41 7**|**50**|
||**30 02 84 3**<br>**30 02 85 6**<br>**30 02 86 9**|**50**<br>**50**<br>**50**|
||**30 30 16 1**<br>**30 30 17 4**<br>**30 30 18 7**<br>**30 30 19 0**<br>**30 30 21 3**<br>**30 30 22 6**|**50**<br>**50**<br>**50**<br>**50**<br>**10**<br>**10**|
||**30 30 72 1**|**50**|
||**30 30 92 5**|**10**|
||**02 01 55 3**<br>**30 30 98 3**|**10**<br>**10**|
||**30 30 94 1**|**10**|
||**12 04 51 7**|**10**|
||**08 08 64 2**|**10**|
||**10 50 00 4**|**10**|
1) Further colors on request.
Phoenix Contact page 4 of 15
**Ground Terminal Block ST 2,5-PE**
ee
(IEC) rigid [mm[2] ] solid stranded AWG IEC 60 947-7-2 0.08-4 0.08-2.5 28-12 EN 50 019* 0.08-4 0.08-2.5 28-12 * EC Prototype certificate no.: KEMA 00ATEX2052U For information on installation and usage of accessories for EEx e applications, see www.clipline.phoenixcontact.com.
Observe the current carrying capacity of mounting rails.
## u P F KEMA
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>green-yellow<br>terminal width 5.2<br>**ST 2,5-PE**<br>**30 31 23 8**<br>**50**<br>(1)**End cover**<br>gray<br>**D-ST 2,5**<br>**30 30 41 7**<br>**50**<br>(2)**Insulating stop sleeve,**prevents unintentional clamping<br>of the insulation in the case of smaller cross sections<br>Cross section range:<br>0.08-0.2 mm2<br>white<br>0.25-0.5 mm2<br>gray<br>0.75-1 mm2<br>black<br>**ISH 2,5/0,2**<br>**30 02 84 3**<br>**50**<br>**ISH 2,5/0,5**<br>**30 02 85 6**<br>**50**<br>**ISH 2,5/1**<br>**30 02 86 9**<br>**50**<br>(3)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 1 - 0,6 x 3,5**<br>**12 04 51 7**<br>**10**<br>(4)**Zack strip,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 5 :UNPRINTED**<br>**08 08 64 2**<br>**10**<br>(5)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 5:UNPRINTED**<br>**10 50 00 4**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>5.2 / 48.5 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>36.5 / 44<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>–<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 2.5<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 2.5<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>0.5<br>**Stripping length**<br>[mm]<br>10<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 3<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>– / – / 26 - 12<br>CSA/CUL: [V] / [A] / AWG<br>– / – / 26 - 12<br>Se EE~~E~~<br>a|**Order No.**<br>EE~~E~~|Pcs<br>.<br>Pkt.<br>~~E~~|
|---|---|---|
||**30 31 23 8**<br>EE~~E~~|**50**<br>~~E~~|
||**30 30 41 7**|**50**|
||**30 02 84 3**<br>**30 02 85 6**<br>**30 02 86 9**|**50**<br>**50**<br>**50**|
||**12 04 51 7**|**10**|
||**08 08 64 2**|**10**|
||**10 50 00 4**|**10**|
Phoenix Contact page 5 of 15
**Feed-Through Terminal Block**
**ST 4**
|(IEC)<br>rigid<br>flexible<br>[mm2]<br>solid<br>stranded|AWG|I<br>[A]|U<br>[V]|
|---|---|---|---|
|IEC 60 947-7-1<br>0.08-6<br>0.08-4|28-10|40|800|
|EN 50 019*<br>0.08-6<br>0.08-4|28-10|34/30|550|
|* EC Prototype certificate no.: KEMA 00ATEX2129U||||
|For information on installation and usage of accessories for EEx e applications,|||For information on installation and usage of accessories for EEx e applications,|
|see www.clipline.phoenixcontact.com.||||
## u P F KEMA
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>gray<br>terminal width 6.2<br>blue<br>terminal width 6.2<br>orange<br>terminal width 6.2<br>red<br>terminal width 6.2<br>black<br>terminal width 6.2<br>**ST 4**<br>**30 31 36 4**<br>**50**<br>**ST 4 BU**<br>**30 31 37 7**<br>**50**<br>**ST 4 OG**<br>**30 37 13 5**<br>**50**<br>**ST 4 RD**<br>**30 37 15 1**<br>**50**<br>**ST 4 BK**<br>**30 37 18 0**<br>**50**<br>(1)**End cover**<br>gray<br>**D-ST 4**<br>**30 30 42 0**<br>**50**<br>(2)**Insulating stop sleeve,**prevents unintentional clamping<br>of the insulation in the case of smaller cross sections<br>Cross section range:<br>0.25-0.5 mm2<br>gray<br>0.75-1 mm2<br>black<br>**ISH 4/0,5**<br>**30 02 88 5**<br>**50**<br>**ISH 4/1**<br>**30 02 89 8**<br>**50**<br>(3)**Plug-in bridge,**for<br>2-pos.<br>cross-connections in the<br>3-pos.<br>terminal center<br>4-pos.<br>5-pos.<br>10-pos.<br>20-pos.<br>**FBS 2-6**<br> Imax.: 32 A<br>**30 30 33 6**<br>**50**<br>**FBS 3-6**<br>32 A<br>**30 30 24 2**<br>**50**<br>**FBS 4-6**<br>32 A<br>**30 30 25 5**<br>**50**<br>**FBS 5-6**<br>32 A<br>**30 30 34 9**<br>**50**<br>**FBS 10-6**<br>32 A<br>**30 30 27 1**<br>**10**<br>**FBS 20-6**<br>32 A<br>**30 30 36 5**<br>**10**<br>(4)**Partition plate,**for<br>visual and electrical separation<br>of terminal groups, 2 mm thick<br>**ATP-ST 4**<br>**30 30 72 1**<br>**50**<br>(5)**Test adapter,**for 4 mm∅test connector PS<br>and 4 mm∅safety test connectors,<br>making contact in the bridge shaft<br>**PAI 4**<br>**30 30 92 5**<br>**10**<br>(6)**2.3 mm**∅**test connector1)**, consisting of<br>metal part and red insulating sleeve<br>(7)**Modular test connector,**can be labeled with ZBF 6<br>**MPS-RD**<br>**02 01 55 3**<br>**10**<br>**PS-6**<br>**30 30 99 6**<br>**10**<br>(8)**Warning cover,**for the<br>operating shafts of the “mini-spring”<br>ST spring cage terminal blocks<br>**WST 4**<br>**30 30 95 4**<br>**10**<br>(9)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 1 - 0,6 x 3,5**<br>**12 04 51 7**<br>**10**<br>(10)**Zack strip,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 6:UNPRINTED**<br>**08 08 71 0**<br>**10**<br>(11)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 6:UNPRINTED**<br>**10 51 00 3**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>6.2 / 56 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>36.5 / 44<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>40 / 6<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 4<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 4<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>0.5 - 1<br>**Stripping length**<br>[mm]<br>10<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 4<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>600 / 30 / 20 - 10<br>CSA/CUL: [V] / [A] / AWG<br>600 / 30 / 20 - 10<br>vu<br>HUY<br>nS<br>SSSe8|**Order No.**|Pcs<br>.<br>Pkt.|
|---|---|---|
||**30 31 36 4**<br>**30 31 37 7**<br>**30 37 13 5**<br>**30 37 15 1**<br>**30 37 18 0**|**50**<br>**50**<br>**50**<br>**50**<br>**50**|
||**30 30 42 0**|**50**|
||**30 02 88 5**<br>**30 02 89 8**|**50**<br>**50**|
||**30 30 33 6**<br>**30 30 24 2**<br>**30 30 25 5**<br>**30 30 34 9**<br>**30 30 27 1**<br>**30 30 36 5**|**50**<br>**50**<br>**50**<br>**50**<br>**10**<br>**10**|
||**30 30 72 1**|**50**|
||**30 30 92 5**|**10**|
||**02 01 55 3**<br>**30 30 99 6**<br>nS|**10**<br>**10**<br>nS|
||**30 30 95 4**|**10**|
||**12 04 51 7**|**10**|
||**08 08 71 0**|**10**|
||**10 51 00 3**|**10**|
1) Further colors on request.
Phoenix Contact page 6 of 15
**Ground Terminal Block**
**ST 4-PE**
(IEC) rigid [mm[2] ] solid stranded AWG IEC 60 947-7-2 0.08-6 0.08-4 28-10 EN 50 019* 0.08-6 0.08-4 28-10 * EC Prototype certificate no.: KEMA 00ATEX2129U For information on installation and usage of accessories for EEx e applications, see www.clipline.phoenixcontact.com. Observe the current carrying capacity of mounting rails. u P F KEMA **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>green-yellow<br>terminal width 6.2<br>**ST 4-PE**<br>**30 31 38 0**<br>**50**<br>(1)**End cover**<br>gray<br>**D-ST 4**<br>**30 30 42 0**<br>**50**<br>(2)**Insulating stop sleeve,**prevents unintentional clamping<br>of the insulation in the case of smaller cross sections<br>Cross section range:<br>0.25-0.5 mm2<br>gray<br>0.75-1 mm2<br>black<br>**ISH 4/0,5**<br>**30 02 88 5**<br>**50**<br>**ISH 4/1**<br>**30 02 89 8**<br>**50**<br>(3)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 1 - 0,6 x 3,5**<br>**12 04 51 7**<br>**10**<br>(4)**Zack strip,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 6:UNPRINTED**<br>**08 08 71 0**<br>**10**<br>(5)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 6:UNPRINTED**<br>**10 51 00 3**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>6.2 / 56 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>36.5 / 44<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>–<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 4<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 4<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>0.5 - 1<br>**Stripping length**<br>[mm]<br>10<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 4<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>– / – / 20 - 10<br>CSA/CUL: [V] / [A] / AWG<br>– / – / 20 - 10<br>ee_~~_~~<br>—<br>eg P<br>ge|**Order No.**<br>ee_~~_~~|Pcs<br>.<br>Pkt.<br>~~_~~|
|---|---|---|
||**30 31 38 0**<br>ee_~~_~~|**50**<br>~~_~~|
||**30 30 42 0**|**50**|
||**30 02 88 5**<br>**30 02 89 8**|**50**<br>**50**|
||**12 04 51 7**|**10**|
||**08 08 71 0**|**10**|
||**10 51 00 3**|**10**|
Phoenix Contact page 7 of 15
**Feed-Through Terminal Block**
**ST 6**
(IEC) rigid I U [mm[2] ] solid stranded AWG [A] [V] IEC 60 947-7-1 0.2-10 0.2-6 24-8 52 800 EN 50 019* 0.2-10 0.2-6 24-8 45/36 550 * EC Prototype certificate no: KEMA 00ATEX2129U
For information on installation and usage of accessories for EEx e applications, see www.clipline.phoenixcontact.com.
## u P F KEMA
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>gray<br>terminal width 8.2<br>blue<br>terminal width 8.2<br>**ST 6**<br>**30 31 48 7**<br>**50**<br>**ST 6 BU**<br>**30 31 49 0**<br>**50**<br>(1)**End cover**<br>gray<br>**D-ST 6**<br>**30 30 43 3**<br>**50**<br>(2)**Plug-in bridge,**for<br>2-pos.<br>cross-connections in the<br>3-pos.<br>terminal center<br>4-pos.<br>5-pos.<br>10-pos.<br>**FBS 2-8**<br> Imax.: 41 A<br>**30 30 28 4**<br>**10**<br>**FBS 3-8**<br>41 A<br>**30 30 29 7**<br>**10**<br>**FBS 4-8**<br>41 A<br>**30 30 30 7**<br>**10**<br>**FBS 5-8**<br>41 A<br>**30 30 31 0**<br>**10**<br>**FBS 10-8**<br>41 A<br>**30 30 32 3**<br>**10**<br>(3)**Reducing bridge,**for connection of one<br>ST 6 with ST 2,5 or ST 4<br>**RB ST 6-(2,5/4)**<br>Imax.: 48 A<br>**30 30 86 0**<br>**10**<br>(4)**Partition plate,**for<br>visual and electrical separation<br>of terminal groups, 2 mm thick<br>**ATP-ST 6**<br>**30 24 48 1**<br>**50**<br>(5)**Test adapter,**for 4 mm∅test connector PS<br>and 4 mm∅safety test connectors,<br>making contact in the bridge shaft<br>**PAI 4**<br>**30 30 92 5**<br>**10**<br>(6)**2.3 mm**∅**test connector1)**, consisting of<br>metal part and red insulating sleeve<br>(7)**Modular test connector,**can be labeled with ZBF 8<br>**MPS-RD**<br>**02 01 55 3**<br>**10**<br>**PS 8**<br>**30 31 00 5**<br>**10**<br>(8)**Warning cover,**for the<br>operating shafts of the “mini-spring”<br>ST spring cage terminal blocks<br>**WST 6**<br>**30 30 96 7**<br>**10**<br>(9)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 2 - 0,8 x 4,0**<br>**12 04 52 0**<br>**10**<br>(10)**Zack marker sheet,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 8:UNPRINTED**<br>**08 08 78 1**<br>**10**<br>(11)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 8:UNPRINTED**<br>**10 52 00 2**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>8.2 / 69.5 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>43.5 / 51<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>52 / 10<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 6<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 6<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>0.5 - 1.5<br>**Stripping length**<br>[mm]<br>12<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 5<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>600 / 50 / 20 - 8<br>CSA/CUL: [V] / [A] / AWG<br>600 / 50 / 20 - 8<br>O~~e~~<br>itt<br>TAY;<br>Th =><br>[of-[[-||**Order No.**<br>~~e~~|Pcs<br>.<br>Pkt.<br>~~e~~|
|---|---|---|
||**30 31 48 7**<br>**30 31 49 0**<br>~~e~~|**50**<br>**50**<br>~~e~~|
||**30 30 43 3**|**50**|
||**30 30 28 4**<br>**30 30 29 7**<br>**30 30 30 7**<br>**30 30 31 0**<br>**30 30 32 3**|**10**<br>**10**<br>**10**<br>**10**<br>**10**|
||**30 30 86 0**|**10**|
||**30 24 48 1**|**50**|
||**30 30 92 5**|**10**|
||**02 01 55 3**<br>**30 31 00 5**|**10**<br>**10**|
||**30 30 96 7**|**10**|
||**12 04 52 0**|**10**|
||**08 08 78 1**|**10**|
||**10 52 00 2**|**10**|
1) Further colors on request.
Phoenix Contact page 8 of 15
**Ground Terminal Block ST 6-PE**
|(IEC)<br>rigid<br>flexible<br>[mm2]<br>solid<br>stranded<br>AWG<br>a|(IEC)<br>rigid<br>flexible<br>[mm2]<br>solid<br>stranded<br>AWG<br>a|(IEC)<br>rigid<br>flexible<br>[mm2]<br>solid<br>stranded<br>AWG<br>a|
|---|---|---|
|IEC 60 947-7-2|0.2-10|0.2-6<br>24-8|
|EN 50 019*|0.2-10|0.2-6<br>24-8|
|* EC Prototype certificate no.: KEMA 00ATEX2129U|* EC Prototype certificate no.: KEMA 00ATEX2129U|* EC Prototype certificate no.: KEMA 00ATEX2129U|
For information on installation and usage of accessories for EEx e applications, see www.clipline.phoenixcontact.com.
Observe the current carrying capacity of mounting rails.
## u P F KEMA
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>green-yellow<br>terminal width 8.2<br>**ST 6-PE**<br>**30 31 50 0**<br>**50**<br>(1)**End cover**<br>gray<br>**D-ST 6**<br>**30 30 43 3**<br>**50**<br>(2)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 2 - 0,8 x 4,0**<br>**12 04 52 0**<br>**10**<br>(3)**Zack marker sheet,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 8:UNPRINTED**<br>**08 08 78 1**<br>**10**<br>(4)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 8:UNPRINTED**<br>**10 52 00 2**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>8.2 / 69.5 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>43.5 / 51<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>–<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 6<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 6<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>0.5 - 1.5<br>**Stripping length**<br>[mm]<br>12<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 5<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>– / – / 20 - 8<br>CSA/CUL: [V] / [A] / AWG<br>– / – / 20 - 8|**Order No.**|Pcs<br>.<br>Pkt.|
|---|---|---|
||**30 31 50 0**|**50**|
||**30 30 43 3**|**50**|
||**12 04 52 0**|**10**|
||**08 08 78 1**|**10**|
||**10 52 00 2**|**10**|
Phoenix Contact page 9 of 15
**Feed-Through Terminal Block ST 10**
|(IEC)<br>[mm2]|rigid<br>solid|flexible<br>stranded|AWG|I<br>[A]|U<br>[V]|
|---|---|---|---|---|---|
|IEC 60 947-7-1|0.2-16|0.2-10|24-6|65|800|
|EC Prototype certificate from 3rd quarter 2002.||||||
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>gray<br>terminal width 10.2<br>blue<br>terminal width 10.2<br>**ST 10**<br>**30 36 11 0**<br>**50**<br>**ST 10 BU**<br>**30 36 12 3**<br>**50**<br>(1)**End cover**<br>gray<br>**D-ST 10**<br>**30 36 64 4**<br>**50**<br>(2)**Plug-in bridge,**for<br>cross-connections in the<br>2-pos.<br>terminal center<br>**FBS 2-10**<br> Imax.: 57 A<br>**30 05 94 7**<br>**10**<br>(3)**Reducing bridge,**for connection of one<br>ST 10 with ST 2,5 or ST 4<br>**RB ST 10-(2,5/4)**<br>Imax.: 55 A<br>**30 30 87 3**<br>**10**<br>(4)**2.3 mm**∅**test connector1)**, consisting of<br>metal part and red insulating sleeve<br>**MPS-RD**<br>**02 01 55 3**<br>**10**<br>(5)**Warning cover,**for the<br>operating shafts of the “mini-spring”<br>ST spring cage terminal blocks<br>**WAZ 10**<br>**08 07 99 9**<br>**25**<br>(6)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 3 - 1,0 x 5,5**<br>**12 06 61 2**<br>**10**<br>(7)**Zack marker sheet,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 8:UNPRINTED**<br>**08 08 78 1**<br>**10**<br>(8)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 10:UNPRINTED**<br>**10 53 00 1**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>10 / 71.5 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>50.5 / 58<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>65 / 16<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 10<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 10<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>1.5 - 2.5<br>**Stripping length**<br>[mm]<br>18<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 6<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>–<br>CSA/CUL: [V] / [A] / AWG<br>–<br>UU<br>TAY;<br>Lh =>|**Order No.**|Pcs<br>.<br>Pkt.|
|---|---|---|
||**30 36 11 0**<br>**30 36 12 3**|**50**<br>**50**|
||**30 36 64 4**|**50**|
||**30 05 94 7**|**10**|
||**30 30 87 3**|**10**|
||**02 01 55 3**|**10**|
||**08 07 99 9**|**25**|
||**12 06 61 2**|**10**|
||**08 08 78 1**|**10**|
||**10 53 00 1**|**10**|
1) Further colors on request.
Phoenix Contact page 10 of 15
**Ground Terminal Block**
**ST 10-PE**
a (IEC) rigid flexible I [mm[2] ] solid stranded AWG [A] IEC 60 947-7-2 0.2-16 0.2-10 16-6 65 Observe the current carrying capacity of mounting rails. EC Prototype certificate from 3rd quarter 2002.
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>green-yellow<br>terminal width 10.2<br>**ST 10-PE**<br>**30 36 13 6**<br>**50**<br>(1)**End cover**<br>gray<br>**D-ST 10**<br>**30 36 64 4**<br>**50**<br>(2)**Plug-in bridge,**for<br>cross connection in the<br>2-pos.<br>terminal center<br>**FBS 2-10**<br> Imax.: 57 A<br>**30 05 94 7**<br>**10**<br>(3)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 3 - 1,0 x 5,5**<br>**12 06 61 2**<br>**10**<br>(4)**Zack marker sheet,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 8:UNPRINTED**<br>**08 08 78 1**<br>**10**<br>(5)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 10:UNPRINTED**<br>**10 53 00 1**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>10 / 71.5 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>50.5 / 58<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>65 / 16<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 10<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 10<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>1.5 - 2.5<br>**Stripping length**<br>[mm]<br>18<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 6<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>–<br>CSA/CUL: [V] / [A] / AWG<br>–<br>tft|**Order No.**|Pcs<br>.<br>Pkt.|
|---|---|---|
||**30 36 13 6**|**50**|
||**30 36 64 4**|**50**|
||**30 05 94 7**|**10**|
||**12 06 61 2**|**10**|
||**08 08 78 1**|**10**|
||**10 53 00 1**|**10**|
Phoenix Contact page 11 of 15
**Feed-Through Terminal Block ST 16**
Oe (IEC)[mm[2] ] solidrigid strandedflexible AWG [A]I [V]U IEC 60 947-7-1 0.2-25 0.2-16 24-4 90 800 EC Prototype certificate from 3rd quarter 2002.
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>gray<br>terminal width 12<br>blue<br>terminal width 12<br>**ST 16**<br>**30 36 14 9**<br>**50**<br>**ST 16 BU**<br>**30 36 15 2**<br>**50**<br>(1)**End cover**<br>gray<br>**D-ST 16**<br>**30 36 65 7**<br>**50**<br>(2)**Plug-in bridge,**for<br>cross-connections in the<br>2-pos.<br>terminal center<br>**FBS 2-12**<br> Imax.: 76 A<br>**30 05 95 0**<br>**10**<br>(3)**Reducing bridge,**for connection of one<br>ST 16 with ST 2,5 or ST 4<br>**RB ST 16-(2,5/4)**<br>Imax.: 63 A<br>**30 30 88 6**<br>**10**<br>(4)**2.3 mm**∅**test connector1)**, consisting of<br>metal part and red insulating sleeve<br>**MPS-RD**<br>**02 01 55 3**<br>**10**<br>(5)**Warning cover,**for the<br>operating shafts of the “mini-spring”<br>ST spring cage terminal blocks<br>**WAZ 12**<br>**08 07 98 6**<br>**25**<br>(6)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 3 - 1,0 x 5,5**<br>**12 06 61 2**<br>**10**<br>(7)**Zack marker sheet,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 8:UNPRINTED**<br>**08 08 78 1**<br>**10**<br>(8)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 10:UNPRINTED**<br>**10 53 00 1**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>12 / 80 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>51 / 58.5<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>90 / 25<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 16<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 16<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>1.5 - 4<br>**Stripping length**<br>[mm]<br>18<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 7<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>–<br>CSA/CUL: [V] / [A] / AWG<br>–<br>rat<br>TAY;<br>==|**Order No.**|Pcs<br>.<br>Pkt.|
|---|---|---|
||**30 36 14 9**<br>**30 36 15 2**|**50**<br>**50**|
||**30 36 65 7**|**50**|
||**30 05 95 0**|**10**|
||**30 30 88 6**|**10**|
||**02 01 55 3**|**10**|
||**08 07 98 6**|**25**|
||**12 06 61 2**|**10**|
||**08 08 78 1**|**10**|
||**10 53 00 1**|**10**|
1) Further colors on request.
Phoenix Contact page 12 of 15
**Ground Terminal Block**
**ST 16-PE**
|(IEC)<br>[mm2]|rigid<br>flexible<br>solid<br>stranded<br>AWG|I<br>[A]|
|---|---|---|
|IEC 60 947-7-2|0.2-25<br>0.2-16<br>24-4|90|
|Observe the current carrying capacity of mounting rails.<br>EC Prototype certificate from 3rd quarter 2002.|||
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>green-yellow<br>terminal width 12<br>**ST 16-PE**<br>**30 36 16 5**<br>**25**<br>(1)**End cover**<br>gray<br>**D-ST 16**<br>**30 36 65 7**<br>**50**<br>(2)**Plug-in bridge,**for<br>cross-connections in the<br>2-pos.<br>terminal center<br>**FBS 2-12**<br> Imax.: 76 A<br>**30 05 95 0**<br>**10**<br>(3)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 3 - 1,0 x 5,5**<br>**12 06 61 2**<br>**10**<br>(4)**Zack marker sheet,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 8:UNPRINTED**<br>**08 08 78 1**<br>**10**<br>(5)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 10:UNPRINTED**<br>**10 53 00 1**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>12 / 80 / 2.2<br>Height (NS 35/7.5 / NS 35/15)<br>[mm]<br>51 / 58.5<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>90 / 25<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>0.25 - 16<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>0.25 - 16<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>1.5 - 4<br>**Stripping length**<br>[mm]<br>18<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 7<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>–<br>CSA/CUL: [V] / [A] / AWG<br>–<br>ee<br>ee<br>OK<br>=|**Order No.**|Pcs<br>.<br>Pkt.|
|---|---|---|
||**30 36 16 5**<br>ee|**25**<br>ee|
||**30 36 65 7**<br>ee|**50**<br>ee|
||**30 05 95 0**<br>ee|**10**<br>ee|
||**12 06 61 2**|**10**|
||**08 08 78 1**<br>OK|**10**<br>OK|
||**10 53 00 1**<br>OK|**10**<br>OK|
Phoenix Contact page 13 of 15
**Feed-Through Terminal Block ST 35**
|(IEC)<br>[mm2]|rigid<br>solid|flexible<br>stranded|AWG|I<br>[A]|U<br>[V]|
|---|---|---|---|---|---|
|IEC 60 947-7-1|2.5-35|2.5-35|14-2|125|800|
|EC Prototype certificate from 3rd quarter 2002.||||||
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>gray<br>terminal width 16<br>blue<br>terminal width 16<br>**ST 35**<br>**30 36 17 8**<br>**10**<br>**ST 35 BU**<br>**30 36 18 1**<br>**10**<br>(1)**Plug-in bridge,**for<br>cross-connections in the<br>2-pos.<br>terminal center<br>**FBS 2-16**<br> Imax.: 101 A<br>**30 05 96 3**<br>**10**<br>(2)**Reducing bridge,**for connection of one<br>ST 35 with ST 2,5 or ST 4<br>**RB ST 35-(2,5/4)**<br>Imax.: 63 A<br>**30 30 89 9**<br>**10**<br>(3)**2.3 mm**∅**test connector1)**, consisting of<br>metal part and red insulating sleeve<br>**MPS-RD**<br>**02 01 55 3**<br>**10**<br>(4)**Warning cover,**for the<br>operating shafts of the “mini-spring”<br>ST spring cage terminal blocks<br>**WAZ 16**<br>**08 07 97 3**<br>**10**<br>(5)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 3 - 1,0 x 5,5**<br>**12 06 61 2**<br>**10**<br>(6)**Zack marker sheet,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 8:UNPRINTED**<br>**08 08 78 1**<br>**10**<br>(7)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 10:UNPRINTED**<br>**10 53 00 1**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>16 / 80 / –<br>Height (NS 35/7,5 / NS 35/15)<br>[mm]<br>59 / 66.5<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>125 / 35<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>2.5 - 35<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>2.5 - 35<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>–<br>**Stripping length**<br>[mm]<br>25<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 8<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>–<br>CSA/CUL: [V] / [A] / AWG<br>–<br>i<br>fat<br>a|**Order No.**|Pcs<br>.<br>Pkt.|
|---|---|---|
||**30 36 17 8**<br>**30 36 18 1**|**10**<br>**10**|
||**30 05 96 3**|**10**|
||**30 30 89 9**|**10**|
||**02 01 55 3**|**10**|
||**08 07 97 3**|**10**|
||**12 06 61 2**|**10**|
||**08 08 78 1**|**10**|
||**10 53 00 1**|**10**|
1) Further colors on request.
Phoenix Contact page 14 of 15
**Ground Terminal Block**
**ST 35-PE**
|(IEC)<br>[mm2]|rigid<br>flexible<br>solid<br>stranded<br>AWG|I<br>[A]|
|---|---|---|
|IEC 60 947-7-2|2.5-35<br>2.5-35<br>14-2|125|
|Observe the current carrying capacity of mounting rails.<br>EC Prototype certificate from 3rd quarter 2002.|||
## **Technical data**
|**Technical data**<br>**Type**<br>**Order No.**<br>Pcs<br>.<br>Pkt.<br>**Spring cage terminal block,**<br>for mounting on3<br>green-yellow<br>terminal width 16<br>**ST 35-PE**<br>**30 36 19 4**<br>**10**<br>(1)**Plug-in bridge,**for<br>cross-connections in the<br>2-pos.<br>terminal center<br>**FBS 2-16**<br> Imax.: 101 A<br>**30 05 96 3**<br>**10**<br>(2)**Screwdriver,**for<br>actuating the tension spring<br>**SZF 3 - 1,0 x 5,5**<br>**12 06 61 2**<br>**10**<br>(3)**Zack marker sheet,**flat,<br>for labeling the outer marker grooves<br>white<br>**ZBF 8:UNPRINTED**<br>**08 08 78 1**<br>**10**<br>(4)**Zack strip,**10-section, for<br>labeling in the terminal center<br>white<br>**ZB 10:UNPRINTED**<br>**10 53 00 1**<br>**10**<br>**Dimensions**<br>Width / length / end cover width<br>[mm]<br>16 / 100 / –<br>Height (NS 35/7,5 / NS 35/15)<br>[mm]<br>59 / 66.5<br>**Technical data in accordance with IEC/ DIN VDE**<br>Maximum load current / cross section<br>[A] / [mm2]<br>125 / 35<br>Rated surge voltage / contamination class<br>[kV] / –<br>8 / 3<br>Surge voltage category / insulation material group<br>– / –<br>III / I<br>**Connection capacity**<br>Stranded with ferrule with plastic sleeve<br>[mm2]<br>2.5 - 35<br>Stranded with ferrule without plastic sleeve<br>[mm2]<br>2.5 - 35<br>Stranded with TWIN ferrule with plastic sleeve<br>[mm2]<br>–<br>**Stripping length**<br>[mm]<br>25<br>**Internal cylindrical gauge (IEC 60 947-1)**<br>A 8<br>**Insulating material**<br>PA<br>Inflammability class in acc. with UL 94<br>V0<br>**Approval data (UL and CSA/CUL)**<br>Nom. voltage / nom. current / conduc. sizes<br>UL: [V] / [A] / AWG<br>–<br>CSA/CUL: [V] / [A] / AWG<br>–<br>a<br>Zo<br>gs|**Order No.**|Pcs<br>.<br>Pkt.|
|---|---|---|
||**30 36 19 4**|**10**|
||**30 05 96 3**<br>a|**10**<br>a|
||**12 06 61 2**<br>Zo|**10**<br>Zo|
||**08 08 78 1**<br>Zo|**10**<br>Zo|
||**10 53 00 1**<br>Zo<br>gs|**10**<br>Zo<br>gs|
Phoenix Contact page 15 of 15
Updated at June 6, 2026
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →