3-123-527
Power Line Filter, General Purpose, 250 VAC, 36 A, Single Phase, 2 Stage, Chassis Mount
- Manufacturer: SCHURTER
- Product type:
- SVHC: No SVHC (21-Jan-2025)
- No. of Phases: Single Phase
- No. of Stages: 2 Stage
- Product Range: FMBB EP Series
- Current Rating: 36A
- Voltage Rating: 250VAC
- Filter Mounting: Chassis Mount
- Filter Applications: General Purpose
- Filter Input Terminals: Stud
- Filter Output Terminals: Stud
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 75.29 € |
| Current stock | 10+ |
| Lead time | 30 days |
**1-Phase AC Filters / DC Filters** FMBB EP https://www.schurter.com /PG84 AC Filter 2-Stage, excellent Attenuation Case ME Case MB Case MF See below: **Approvals and Compliances** ## **Description** - Line filter in standard and medical version - 2 stage - Compact design - Very light due to partial potting ## **Unique Selling Proposition** - Excellent differential and common-mode attenuation - Broad band attenuation - Completely closed steel housing - Wide temperature range ## **Characteristics** - Designed for current applications of 1 - 36 A - Protection against interference voltage from the mains - Possible interferences generated in the equipment are strongly attenuated - Especially designed for industrial applications such as: Frequency Converters, Stepper Motor Drives, UPS-Systems, Inverters - Suitable for use in equipment according to IEC/UL 62368-1 Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP) ## **References** Alternative: High attenuation version FMBB NEO ## **Weblinks** pdf data sheet, html datasheet, General Product Information, Approvals, Distributor-Stock-Check, Detailed request for product, Microsite |**Technical Data**|||| |---|---|---|---| |Ratings IEC|1-36 A @ Ta 40°C / 250 VAC; 50 Hz|Line Filter|Standard and Medical Version, IEC| |Ratings UL/CSA|1 - 36 A @ Ta 40 °C / 125/250 VAC;||60939, UL 60939-3, CSA C22.2 no. 8| ||60 Hz||Technical Details| |Leakage Current|standard < 0.5 mA (250 V / 50 Hz)|MTBF|> 200'000 h acc. to MIL-HB-217 F| ||medical (M5) < 5 µA resp. (M80) < 80||| ||µA (250 V / 50 Hz)||| |Dielectric Strength|1.7 kVDC between L-N||| ||2.7 kVDC between L/N-PE||| ||Test voltage (2 sec)||| |Allowable Operation Tempe-|-40 °C to 100 °C||| |rature|||| |Climatic Category|40/100/21 acc. to IEC 60068-1||| |IP-Protection|rear-side IP20 IEC 60529||| |Protection Class|Suitable for appliances with protection||| ||class I acc. to IEC 61140||| |Terminal|Quick connect terminal 6.3 x 0.8 mm||| ||Bolt and nut M4||| |Material|Nickel plated steel||| ## **Approvals and Compliances** Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. EMC Products **1** **1-Phase AC Filters / DC Filters** https://www.schurter.com /PG84 FMBB EP ## **Approvals** The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: FMBB EP ||**Approval Logo**|**Approval Logo**|**Certificates**|**Certification Body**|**Description**| |---|---|---|---|---|---| |Ke|||VDE Approvals|VDE|Certificate Number: 40051449| ||||UL Approvals|UL|UR File Number: E495089| |**Product standards**|||||| |Product standards that are referenced|||||| ||**Organization**||**Design**|**Standard**|**Description**| ||||Designed according to|IEC 60939|Passive filters for suppressing electromagnetic interference| ||||||| ||||Designed according to|IEC 60127-6|Miniature fuses. Part 6. Fuse-holders for miniature fuse-links| ||||Designed according to|UL 60939-3|Electromagnetic interference filters| ||||Designed according to|CSA C22.2 no. 42|General Use Receptacles, Attachment Plugs, and Similar Wiring Devices| ||||Designed according to|CSA C22.2 no. 8|Electromagnetic interference (EMI) filters| |**Application standards**|||||| |Application standards where the product can be used|||||| ||**Organization**||**Design**|**Standard**|**Description**| ||||Suitable for applications acc.|IEC/UL 62368-1|Audio/video, information and communication technology equipment - Part<br>1: Safety requirements| ||||Suitable for applications acc.|IEC 60601-1|Medical electrical equipment - Part 1: General requirements for basic<br>safety and essential performance| |**Compliances**|||||| |The product complies with following Guide Lines|||||| ||**Identification**||**Details**|**Initiator**|**Description**| |CE|||CE declaration of conformity|SCHURTER AG|The CE marking declares that the product complies with the applicable<br>requirements laid down in the harmonisation of Community legislation on| ||||||its affixing in accordance with EU Regulation 765/2008.| |UK|||UKCA declaration of conformity|SCHURTER AG|The UKCA marking declares that the product complies with the applicable| |cA|||||requirements laid down in the British Amendment of Regulation (EC)| ||||||765/2008.| ||||RoHS|SCHURTER AG|Directive RoHS 2011/65/EU, Amendment (EU) 2015/863| |~~©~~|||China RoHS|SCHURTER AG|The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March<br>2007. It is similar to the EU directive RoHS.| ||||REACH|SCHURTER AG|On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,| ||||||Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as| ||||||"REACH") entered into force.| ||||Medical Equipment|SCHURTER AG|Suitable for use in medical equipment according to IEC/UL 60601-1 (1| ||||||MOOP, 1 MOPP)| | **2** | ELSCHURTER | EMC Products **1-Phase AC Filters / DC Filters** FMBB EP https://www.schurter.com /PG84 ## **Dimension [mm]** Case 09 with quick connect terminals **==> picture [296 x 168] intentionally omitted <==** **----- Start of picture text -----**<br> max. 77 max. 46<br>27 max. 52 17.5<br>60.4 [±0.5]<br>6.3x0.8<br>1) 2)<br>(5x)<br>7.5<br>12 max. 31<br>±0.3<br>4.8 (2x)<br>**----- End of picture text -----**<br> 1) Line 2) Load Case MB with bolt and nut M4 **==> picture [394 x 234] intentionally omitted <==** **----- Start of picture text -----**<br> max. 160 max. 58<br>27 max. 131 15.2<br>4)<br>5)<br>max. 156<br>144 [±0.5]<br>140 ±0.5<br>3)<br>4) 1) 2)<br>13<br>max. 46<br>12<br>±0.3<br>5.3 (2x)<br>M4 (4x)<br>**----- End of picture text -----**<br> 1) Line 2) Load - 3) Nut torque 0.8...1 Nm, keep lock-nut fastened - 4) Lock-nut do not unscrew - 5) PE: M4x16, 1.2...1.5 Nm, keep lock-nut fastened EMC Products **3** **1-Phase AC Filters / DC Filters** https://www.schurter.com /PG84 FMBB EP Case MC with quick connect terminals **==> picture [305 x 164] intentionally omitted <==** **----- Start of picture text -----**<br> max. 90 max. 51<br>27 max. 66 21<br>75 [±0.5]<br>6.3x0.8<br>(5x)<br>1) 2)<br>6<br>12 max. 31<br>±0.3<br>5.3 (2x)<br>**----- End of picture text -----**<br> ## 1) Line 2) Load Case UB with quick connect terminals **==> picture [307 x 187] intentionally omitted <==** **----- Start of picture text -----**<br> max. 90 max. 51<br>27 max. 66 11.4<br>75 [±0.5]<br>6.3x0.8<br>(5x)<br>1) 2)<br>max.41 10.4<br>12<br>±0.3<br>5.3 (2x)<br>**----- End of picture text -----**<br> 1) Line 2) Load EMC Products **4** **1-Phase AC Filters / DC Filters** FMBB EP https://www.schurter.com /PG84 Case ME with quick connect terminals **==> picture [427 x 553] intentionally omitted <==** **----- Start of picture text -----**<br> max. 112 max. 52<br>27 max. 87 12<br>max. 115<br>104.5 [±0.5]<br>97.5 [±0.5]<br>6.3x0.8<br>(5x)<br>1) 2)<br>max. 130 max. 85<br>max. 98 40<br>max. 120<br>109 [±0.3] 4.4 [±0.3]<br>(4x)<br>3)<br>5)<br>4) 1) 2)<br>max. 46 13<br>12<br>±0.3<br>5.3 (2x)<br>max. 59<br>16<br> ±0.5 ±0.5<br>47.5 54.5<br>M4 (4x)<br>**----- End of picture text -----**<br> 1) Line 2) Load Case MF with bolt and nut M4 1) Line 2) Load - 3) Nut torque 0.8...1 Nm, keep lock-nut fastened 4) Lock-nut do not unscrew - 5) PE: M4x16, 1.2...1.5 Nm, keep lock-nut fastened EMC Products **5** **1-Phase AC Filters / DC Filters** https://www.schurter.com /PG84 FMBB EP ## **Diagrams** **==> picture [499 x 294] intentionally omitted <==** **----- Start of picture text -----**<br> Standard and low leakage current Medical M5<br>L L L L<br>L L L L<br>C, C,<br>1) PE cH C , o C , C : Cc 2) 1) PE o ff C , a C , 2)<br>©<br>N N ’ N N’<br>1) Line, 2) Load<br>Medical M80<br>L L<br>C,<br>1) PE cH C , or C , C 2)<br>©<br>N N’<br>1) Line, 2) Load<br>**----- End of picture text -----**<br> **Attenuation Loss** . . . . . 0.1/100 Ω differential mode ........... 100/0.1 Ω differential mode - - - - 50 Ω differential mode _____ 50 Ω common mode Standard version **==> picture [276 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> 1A 3A 6A<br>ap80 6Beo oeLT eeeTT a60<br>oad AL Lest a r iyi PAP<br>A) ca ia y is A A | ip 8<br>ao LA A ana ao LA nn 40<br>aE ee ee 0 20<br>O01 o1 1 40 400 400 MHz 0.01 O41 1 10 100 400 MHz 0.01<br>12 A 16 A 20 A<br>**----- End of picture text -----**<br> **==> picture [19 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> 10 A<br>a0<br>60<br>4“<br>2<br>001<br>30 A<br>**----- End of picture text -----**<br> **==> picture [18 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 36 A<br>**----- End of picture text -----**<br> EMC Products **6** **1-Phase AC Filters / DC Filters** FMBB EP https://www.schurter.com /PG84 Medical version (M5) 1 A 3 A 6 A 10 A <8pegs ERE A S| 4 808 FHA Eiht Ht <8pegs ERE A |[|] a)0 eo tt Ul iat)! OY eo | eee Say eo | ee Ear « eo AE et | St ” NN oH mi SE LP, AR «0 ao CHAS Tt poy A S| | | ao a ee imar 2» 0 RA Pog ee | | re aaais eee ees oe 0 peng MM | a STE ee on ath eee aa rt 20 0.01 o1 1 10 100 400 MHz 001 o1 1 10 100 400 MHz oot 1 1 10 100 400 MHz 001 12 A 16 A 20 A 30 A **==> picture [405 x 242] intentionally omitted <==** **----- Start of picture text -----**<br> 36 A<br>38 yoyo<br>oe A ts: ee<br>oo MEE! erat A<br>TT tt<br>Peg | | |<br>ry | A) |)<br>on ot 1 10 100. 400 MHz<br>Medical version (M80)<br>1 A 3 A 6 A 10 A<br>« & 8 ¢ «8<br>60 " Mae: arti ba 8 -\ eo Ltt Hors AHH7 iat eo | ee eo<br>2 ON oo A Poy St | 20<br>° See eer + ° a I O01 RE ° eee eer BEIT °<br>0.01 01 1 10 100 400 MHz 0.01 O41 1 10 100 400 MHz 0.01 01 1 10 100 400 MHz 0.01<br>12 A 16 A 20 A 30 A<br>**----- End of picture text -----**<br> 36 A EMC Products **7** **1-Phase AC Filters / DC Filters** https://www.schurter.com /PG84 FMBB EP **==> picture [405 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> Low leakage current version<br>1 A 3 A 6 A 10 A<br>Pz) a) a) a)<br>cI me TF O00! se |<br>40 ry|) aa vfmahi} 4 Ny 0 if Setaoma | sd a. ng “ atti Fama1 ttt %ay 0<br>okANA o eonee 1 at oSFINA pt |<br>0.01 o1 1 10 100 400 MHz 0.01 o1 1 10 100 400 MHz 0.01 o1 1 10 100 400 MHz 0.01<br>12 A 16 A 20 A 30 A<br>**----- End of picture text -----**<br> **==> picture [18 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 36 A<br>**----- End of picture text -----**<br> ## **All Variants** **==> picture [458 x 353] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||||||| |---|---|---|---|---|---|---|---|---|---|---| |Rated|Filter-Type|Terminal|Lea-|Ri|Power|Weight|Housing|Packa-|Order Number| |current|kage|Loss|ging| |[A]|[mA]|[m|Ω|]|[W]|[g]|[ST]| |1|Standard version|Quick connect terminal 6.3 x 0.8 mm|1.47|600|1.2|125 g|09|15|3-123-509|█| |3|Standard version|Quick connect terminal 6.3 x 0.8 mm|1.47|168|3|128 g|09|15|3-123-510|█| |6|Standard version|Quick connect terminal 6.3 x 0.8 mm|1.47|40|2.88|133 g|09|15|3-123-511|█| |10|Standard version|Quick connect terminal 6.3 x 0.8 mm|6.91|8.6|4.4|198 g|MC|10|3-123-522|█| |12|Standard version|Quick connect terminal 6.3 x 0.8 mm|3.14|6.2|4.15|201 g|MC|10|3-123-523|█| |16|Standard version|Quick connect terminal 6.3 x 0.8 mm|3.14|8.0|4.1|265 g|UB|10|3-123-524|█| |20|Standard version|Quick connect terminal 6.3 x 0.8 mm|3.14|6|4.8|390 g|ME|5|3-123-525|█| |30|Standard version|Bolt and nut M4|3.14|6|10.8|855 g|MF|3|3-123-526|█| |36|Standard version|Bolt and nut M4|3.14|4.2|10.4|890 g|MB|4|3-123-527|█| |1|Low leakage current|Quick connect terminal 6.3 x 0.8 mm|0.15|600|1.2|125 g|09|15|3-123-537| |3|Low leakage current|Quick connect terminal 6.3 x 0.8 mm|0.15|168|3|128 g|09|15|3-123-538| |6|Low leakage current|Quick connect terminal 6.3 x 0.8 mm|0.15|40|2.88|133 g|09|15|3-123-539| |10|Low leakage current|Quick connect terminal 6.3 x 0.8 mm|0.15|8.6|4.4|198 g|MC|10|3-123-540| |12|Low leakage current|Quick connect terminal 6.3 x 0.8 mm|0.15|6.2|4.15|201 g|MC|10|3-123-541| |16|Low leakage current|Quick connect terminal 6.3 x 0.8 mm|0.15|8.0|4.1|265 g|UB|10|3-123-542| |20|Low leakage current|Quick connect terminal 6.3 x 0.8 mm|0.15|6|4.8|390 g|ME|5|3-123-543| |30|Low leakage current|Bolt and nut M4|0.15|6|10.8|855 g|MF|3|3-123-544| |36|Low leakage current|Bolt and nut M4|0.15|4.2|10.4|890 g|MB|4|3-123-545| |1|Medical Version (M5)|Quick connect terminal 6.3 x 0.8 mm|0.005|600|1.2|125 g|09|15|3-123-528| |3|Medical Version (M5)|Quick connect terminal 6.3 x 0.8 mm|0.005|168|3|128 g|09|15|3-123-529| |6|Medical Version (M5)|Quick connect terminal 6.3 x 0.8 mm|0.005|40|2.88|133 g|09|15|3-123-530| |10|Medical Version (M5)|Quick connect terminal 6.3 x 0.8 mm|0.005|8.6|4.4|198 g|MC|10|3-123-531| |12|Medical Version (M5)|Quick connect terminal 6.3 x 0.8 mm|0.005|6.2|4.15|201 g|MC|10|3-123-532| |16|Medical Version (M5)|Quick connect terminal 6.3 x 0.8 mm|0.005|8.0|4.1|265 g|UB|10|3-123-533| |20|Medical Version (M5)|Quick connect terminal 6.3 x 0.8 mm|0.005|6|4.8|390 g|ME|5|3-123-534| **----- End of picture text -----**<br> EMC Products **8** **1-Phase AC Filters / DC Filters** FMBB EP https://www.schurter.com /PG84 **==> picture [438 x 174] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||||| |---|---|---|---|---|---|---|---|---|---| |Rated|Filter-Type|Terminal|Lea-|Ri|Power|Weight|Housing|Packa-|Order Number| |current|kage|Loss|ging| |[A]|[mA]|[m|Ω|]|[W]|[g]|[ST]| |30|Medical Version (M5)|Bolt and nut M4|0.005|6|10.8|855 g|MF|3|3-123-535| |36|Medical Version (M5)|Bolt and nut M4|0.005|4.2|10.4|890 g|MB|4|3-123-536| |1|Medical Version (M80)|Quick connect terminal 6.3 x 0.8 mm|0.073|600|1.2|125 g|09|15|3-142-126| |3|Medical Version (M80)|Quick connect terminal 6.3 x 0.8 mm|0.073|168|3|128 g|09|15|3-142-127| |6|Medical Version (M80)|Quick connect terminal 6.3 x 0.8 mm|0.073|40|2.88|133 g|09|15|3-142-128| |10|Medical Version (M80)|Quick connect terminal 6.3 x 0.8 mm|0.073|8.6|4.4|198 g|MC|10|3-142-129| |12|Medical Version (M80)|Quick connect terminal 6.3 x 0.8 mm|0.073|6.2|4.15|201 g|MC|10|3-142-130| |16|Medical Version (M80)|Quick connect terminal 6.3 x 0.8 mm|0.073|8.0|4.1|265 g|UB|10|3-142-131| |20|Medical Version (M80)|Quick connect terminal 6.3 x 0.8 mm|0.073|6|4.8|390 g|ME|5|3-142-132| |30|Medical Version (M80)|Bolt and nut M4|0.073|6|10.8|855 g|MF|3|3-142-133| |36|Medical Version (M80)|Bolt and nut M4|0.073|4.2|10.4|890 g|MB|4|3-142-134| **----- End of picture text -----**<br> █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Leakage current according IEC 60939-1 20A, 30A and 36A medical filter M5 and M80, are only suitable for medical equipment intended for permanently connection to the mains. ## **Accessories** **==> picture [143 x 76] intentionally omitted <==** **----- Start of picture text -----**<br> Description<br>DIN_Rail_Kit<br>Mounting accessory for compact 1- and 3-phase filters<br>**----- End of picture text -----**<br> The specifications, descriptions and illustrations indicated in this document are based on current ~~information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.~~ EMC Products **9**
Updated at April 28, 2026
SCHURTER is a globally recognized innovator and manufacturer of high-quality electronic components, specializing in products that ensure a safe and clean supply of power. With a strong reputation in the electronics and PCB assembly industries, the company delivers reliable solutions engineered to protect critical circuits, streamline device operation, and optimize electrical performance across diverse applications. The core of our SCHURTER portfolio revolves around comprehensive circuit protection. We carry an extensive selection of standard and resettable fuses, accompanied by robust fuse holders, to safeguard sensitive electronics against overcurrent conditions. Furthermore, our offering features high-performance thermal circuit breakers and associated accessories, providing dependable protection and rapid reset capabilities for demanding industrial and commercial environments. Beyond fundamental circuit protection, SCHURTER excels in electromagnetic compatibility (EMC) and RFI suppression technologies. Our range includes precision-engineered power line filters and common mode chokes designed to mitigate electromagnetic interference and ensure signal integrity. Accompanied by specialized components such as AC/DC LED power supplies, SCHURTER provides the meticulous engineering and durability necessary for modern, high-reliability electronic design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →