Image not available
Illustrative purposes only
2C10UL
MCCB, 2P, 10A, 480VAC, DIN RAIL
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ALTECH
- Product type: Thermal Magnetic Circuit Breakers
- Product Range:UL Series; Current Rating:10A; No. of Poles:2 Pole; Voltage Rating VDC:-; Voltage Rating VAC:480V; Circuit Breaker Mounting:DIN Rail 95AK4314
- SVHC: To Be Advised
- No. of Poles: 2 Pole
- Product Range: UL Series
- Current Rating: 10A
- Voltage Rating VAC: 480V
- Voltage Rating VDC: -
- Circuit Breaker Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 48.15 € |
| Current stock | 10+ |
| Lead time | 30 days |
## UL-Series - UL489 Miniature Molded Case Circuit Breaker - **2 pole C-Trip - AC** **==> picture [489 x 448] intentionally omitted <==** **----- Start of picture text -----**<br> Rated Type/ Rated 1.05-1.35xI60 N<br>C US C C Current Cat. No. Voltage 40 cnc<br>LISTEDC.B. 0.3A 2C03UL 480Y/277V AC 10 tn<br>E329510 Two Pole 0.5A 2C05UL 480Y/277V AC Thermal Overload<br>1.0A 2C1UL 480Y/277V AC 4 “Must Trip” < 1 hr = 135% RC<br>“Must Not Trip” > 1 hr = 105% RC<br>1.6A 2C1.6UL 480Y/277V AC LA 1 a<br>2.0A 2C2UL 480Y/277V AC<br>3.0A 2C3UL 480Y/277V AC 10 Mea<br>4.0A 2C4UL 480Y/277V AC<br>4 a<br>Lae 5.0A8.0A 6.0A 2C5UL2C8UL 2C6UL 480Y/277V AC480Y/277V AC 480Y/277V AC 0.41 >ae) aee| tt<br>10A 2C10UL 480Y/277V AC<br>oo! 12A 13A 2C12UL 2C13UL 480Y/277V AC 480Y/277V AC 4x1010 [-1][-2] |ne ee<br>15A 2C15UL 480Y/277V AC<br>16A 2C16UL 480Y/277V AC 10 [-2]<br>u al Gan<br>20A 2C20UL 480Y/277V AC 4x10 [-3] | [dL]<br>Standard Pack: 6 25A 2C25UL 480Y/277V AC L 10 [-3] LUE | ettPr<br>30A 2C30UL 480Y/277V AC 1 2 3 4 5 6 8 10 20 40 100<br>Weight: 32A 2C32UL 480Y/277V AC L, Multiple of Rated Current<br>0.3-32A: 40A 2C40UL 240V AC 0.3A Through 10A Rated Current<br>1.74kg (3.83lb.) 50A 2C50UL 240V AC<br>40-63A: 60A 2C60UL 240V AC 1.05-1.35xIN<br>1.98kg (4.37lb.) 63A 2C63UL 240V AC 604010 :inn oo<br>Thermal Overload<br>0.3 - 63A/ 240V AC, 0.3-32A/ 480Y/277V AC* 4 “Must Trip” < 1 hr = 135% RC<br>“Must Not Trip” > 1 hr = 105% RC<br>40ºC (104ºF) L 1 a a<br>-25ºC to +55ºC (-13ºF to 131ºF )<br>-40ºC to +70ºC (-40ºF to 158ºF ) 10 LU<br>4<br>> 15g according to DIN EN 60069-2-59 during a load10000 switching cycles ON/ OFF2 Nm (17.7 lb.in.) / 2.5Nm (22.2 lb.in)6000 switching cycles ON/ OFF 100.4 [-1] 1 aaeae)a“Unea<br>with I1 = 1.05 x IN 4x10 [-2] ne) ee<br>Resistance to mechanical shocks 25g @ 11ms 10 [-2] al Gam<br>4x10 [-3] | [||]<br>One device dual voltage ratings. L 10 [-3] LUM | Pr(Sts<br>1 2 3 4 5 6 8 10 20 40 100<br>L, Multiple of Rated Current<br>Minutes<br>Tripping time t<br>Seconds<br>Minutes<br>Tripping time t<br>Seconds<br>**----- End of picture text -----**<br> |**Current/ Voltage Rating**<br>**Calibration Temperature**<br>**Ambient Temperature**<br>**Storage Temperature**<br>**Terminal Torque (min/max)**<br>**Electrical Life**<br>**Mechanical Life**<br>**Vibration Resistance**<br>**Resistance to mechanical shocks**|0.3 - 63A/ 240V AC, 0.3-32A/ 480Y/277V AC*<br>40ºC (104ºF)<br>-25ºC to +55ºC (-13ºF to 131ºF )<br>-40ºC to +70ºC (-40ºF to 158ºF )<br>2 Nm (17.7 lb.in.) / 2.5Nm (22.2 lb.in)6000 switching cycles ON/ OFF<br>6000 switching cycles ON/ OFF<br>10000 switching cycles ON/ OFF2 Nm (17.7 lb.in.) / 2.5Nm (22.2 lb.in)6000 switching cycles ON/ OFF<br>> 15g according to DIN EN 60069-2-59 during a load10000 switching cycles ON/ OFF2 Nm (17.7 lb.in.) / 2.5Nm (22.2 lb.in)6000 switching cycles ON/ OFF<br>with I1 = 1.05 x IN<br>25g @ 11ms| |---|---| * _One device dual voltage ratings._ **==> picture [196 x 199] intentionally omitted <==** **----- Start of picture text -----**<br> 51.5 mm<br>37.5 mm<br>25.5 mm<br>6 7<br>ini<br>anh ST TIL<br>35 mm 8 4<br>2 Pole<br>14.5 mm<br>ee _ 30.5 mm<br>51.5 mm<br>68.4 mm<br>36.8 mm<br>105.3 mm 34.5 mm 45 mm<br>36.5 mm<br>52.5 mm<br>**----- End of picture text -----**<br> 12A Through 63A Rated Current ## **“C” Magnetic Trip Parameters** Rated current 0.3A to 63A. 1. Hold for a minimum of 100ms at surge of 5 times rated current. 2. Trip in under 100ms at 10 times rated current. ## Short Circuit Interrupting Capacity ## AC |**No.**|||| |---|---|---|---| |**No.**<br>**Poles**|**Type**|**03-32A**|**33-63A**| |2-3|AC|10kA @ 120, 240,<br>480Y/277V|10kA @ 120<br>240V|
Updated at April 12, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →