Analogue Timer, ETD, On-Delay, On-Pulse, 50 ms, 100 h, 7 Ranges, 1 Changeover Relay
- Manufacturer: PHOENIX CONTACT
- Product type: Analogue Timers - DIN Rail
- Product Range:ETD Series; Timer Functions:On-Delay, On-Pulse; Time Min:50ms; Time Max:100h; No. of Timing Ranges:7Ranges; Timer Output:1 Changeover Relay; Supply Voltage Max:240V;
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 100h
- Time Min: 50ms
- Timer Output: 1 Changeover Relay
- Product Range: ETD
- Timer Functions: On-Delay, On-Pulse
- Current Rating Nom: -
- Supply Voltage Max: 240V
- No. of Timing Ranges: 7Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 61.94 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **ETD-BL-2T-I-230(-PT)** ## **Timer relay with adjustable pulse and pause times** Data sheet 106851_en_02 © PHOENIX CONTACT 2016-08-15 ## **1 Description** Requirements pertaining to safety and system availability increase constantly – regardless of the industry. Processes are becoming more and more complex, not only in the mechanical engineering and chemical industry but also in plant and automation technology. Demands on power engineering are also constantly on the rise. Timer relays of the ETD series are available for controlling the time sequences in production and process engineering. ## **Features** - Adjustable pulse and pause times - Time range from 50 ms to 100 h (seven setting ranges) - Timer function - Wide-range power supply unit - 1 floating PDT **WARNING: Risk of electric shock** Never carry out work when voltage is present. ~~Bo~~ Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. This document is valid for the products listed in the “Ordering data”. ~~Me~~ **ETD-BL-2T-I-230(-PT)** |**2**|**Table of contents**| |---|---| |1|Description .............................................................................................................................. 1| |2|Table of contents..................................................................................................................... 2| |3|Ordering data .......................................................................................................................... 3| |4|Technical data ......................................................................................................................... 3| |5|Safety notes............................................................................................................................. 4| |6|Basic circuit diagram ............................................................................................................... 5| |7|Structure.................................................................................................................................. 5| |8|Installation ............................................................................................................................... 5| |9|Time setting............................................................................................................................. 5| |10|Diagnostics.............................................................................................................................. 5| |11|Connection examples.............................................................................................................. 6| |12|Function................................................................................................................................... 6| PHOENIX CONTACT **2 / 6** **106851_en_02** **ETD-BL-2T-I-230(-PT)** ## **3 Ordering data** |**Description**|**Type**|**Order No.**|**Pcs./Pkt.**| |---|---|---|---| |Compact impulse encoder with adjustable pulse and pause times (50 ms -|ETD-BL-2T-I-230|2907713|1| |100 h), wide range power supply unit, with screw connection, 1 PDT|||| |Compact impulse encoder with adjustable pulse and pause times (50 ms -|ETD-BL-2T-I-230-PT|2907714|1| |100 h), wide range power supply unit, with push-in connection, 1 PDT|||| ## **4 Technical data** |**Input data**|| |---|---| |Input voltage range|24 V DC ... 240 V DC -10 % ... +15 %| |Nominal frequency|48 Hz ... 63 Hz| |Temperature coefficient, typical|≤ 0.01 %/K| |Recovery time|500 ms| |Time setting range|50 ms ... 100 h (7 time end ranges)| |Function|lp: Switched-mode beginning with the pause| ||li: Switched-mode beginning with the pulse| |Basic accuracy|± 1 % (of scale end value)| |Setting accuracy|≤ 5 % (of scale end value)| |Repeat accuracy|≤ 0.5 % ±5 ms| |Nominal power consumption|2.5 VA (1 W)| ||| |**Output data**|| |Contact type|1 floating PDT| |Maximum switching voltage|250 V AC (in acc. with IEC 60664-1)| |Interrupting rating (ohmic load) max.|750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing)| ||1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing)| |Output fuse|5 A (fast-blow)| ||| |**Control contact**|| |Control contact|Non-floating, terminals A1-B1| |Control pulse length|≥ 50 ms (DC)| ||| |**General data**|| |Mechanical service life|Approx. 2 x 107cycles| |Service life, electrical|Approx. 2 x 105cycles at ohmic load, 1000 VA| |Switching frequency|max. 60 (per minute at 100 VA ohmic load)| ||max. 6 (per minute at 1000 VA ohmic load)| |Operating mode|100% operating factor| |Degree of protection|IP40 (housing) / IP20 (connection terminal blocks)| |Degree of pollution|2 (according to EN 50178)| |Overvoltage category|III, basic insulation (as per EN 50178)| |Rated insulation voltage|300 V (According to EN 50178)| |Flammability rating according to UL 94|V0| |Mounting|on standard DIN rail NS 35 in accordance with EN 60715| |Mounting position|any| |Width|17.5 mm| |Height|88 mm| |Depth|65.5 mm| |Color|gray| PHOENIX CONTACT **3 / 6** **106851_en_02** **ETD-BL-2T-I-230(-PT)** |**Connection data**|**Screw connection**|**Push-in connection**| |---|---|---| |Conductor cross section, solid|0.14 mm² ... 2.5 mm²|0.5 mm² ... 2.5 mm²| |Conductor cross section, flexible|0.14 mm² ... 2.5 mm²|0.5 mm² ... 2.5 mm²| |AWG|20 ... 14|26 ... 14| |Stripping length|8 mm|8 mm| |||| |**Ambient conditions**||| |Ambient temperature (operation)|-25 °C ... 55 °C|| ||-25 °C ... 40 °C (corresponds to UL 508)|| |Ambient temperature (storage/transport)|-25 °C ... 70 °C|| |Permissible humidity (operation)|15 % ... 85 %|| |||| |**Conformance/Approvals**||| |Conformance|CE-compliant|| |||| |**Conformance with EMC Directive 2014/30/EU**||| |Noise immunity according to|EN 61000-6-2|| |Noise emission according to|EN 61000-6-4|| |||| |**Conformance with Low Voltage Directive 2014/35/EC**||| |Industrial timer relays according to|EN 61812-1/A11|| ## **5 Safety notes** **WARNING: Risk of electric shock** Never carry out work when voltage is present. PHOENIX CONTACT **4 / 6** **106851_en_02** **ETD-BL-2T-I-230(-PT)** ## **6 Basic circuit diagram** **==> picture [175 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> 16 18<br>B1<br>A1 (+) t<br>A2 (-)<br>15<br>U = 24...240 V AC/DC<br>Figure 1 Block diagram<br>**----- End of picture text -----**<br> ## **8 Installation** ## **WARNING: Risk of electric shock** Never carry out work when voltage is present. The module can be snapped onto all 35 mm DIN rails according to EN 60715. An integrated wide-range power supply unit enables the connection of a supply voltage in the range from 24 V AC/ DC to 240 V AC/DC. ## **9 Time setting** ## **7 Structure** **==> picture [191 x 217] intentionally omitted <==** **----- Start of picture text -----**<br> 7<br>6<br>5<br>4<br>3<br>2<br>1<br>U/t 0.5 .2<br>.4<br>s 11 10 .6<br>1 m<br>1000.5h10h1h10<br>.2<br>.4<br>R s 11 10.8 .61 m<br>100h10h1h10<br>.8<br>15<br>A1<br>B1<br>-230-PT-IT2ETD-BL-<br>**----- End of picture text -----**<br> - **1** Rotary switch "TIME2": Time end range - **2** LED "R": output relay - **3** "TIME2" potentiometer: Preset value - **4** Rotary switch "TIME1": Time end range - **5** "TIME1" potentiometer: Preset value - **6** "U/t" LED: Supply and adjustable time TIME **==> picture [88 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> 2<br>0.5 .2<br>U/t .4<br>.6<br>1 .8<br>1 s 1 10 1 m<br>10<br>100h10h1h<br>0.5 .2<br>.4<br>.6<br>1 .8<br>s 1 10 1 m<br>R 10<br>100h10h1h<br>ETD-BL-T-I-230-PT2<br>**----- End of picture text -----**<br> - **1** Specification of the time end range using a rotary switch, e.g. 10 m (10 minutes) - **2** Fine setting of the time using a potentiometer, e.g. 0.4 **Set time:** 0.4 x 10 minutes = 4 minutes ## **10 Diagnostics** The LEDs indicate the following error states: ## **"U/t" LED (Green)** - LED flashes: Voltage present, set time running - LED ON: Voltage present, set time has elapsed ## **“R” LED (yellow)** - LED ON: Output relay has picked up - LED OFF: Output relay has dropped out - **7** Snap-on foot for DIN rail mounting PHOENIX CONTACT **5 / 6** **106851_en_02** **ETD-BL-2T-I-230(-PT)** ## **11 Connection examples** **==> picture [7 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>**----- End of picture text -----**<br> ## **12 Function** **NOTE: Module can become damaged** Only set the functions when the module is switched off. ## **Switched-mode beginning with pause - Ip** **==> picture [41 x 107] intentionally omitted <==** **----- Start of picture text -----**<br> 15<br>A1 B1<br>A1 15<br>R<br>A2 16 18<br>A2<br>16 18<br>**----- End of picture text -----**<br> Figure 2 Switched-mode beginning with pause **==> picture [7 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>**----- End of picture text -----**<br> When supply voltage U is applied, set time t1 starts running (green "U/t" LED flashes at 0.75 Hz). Once time t1 has elapsed, the output relay picks up (yellow "R" LED is ON) and set time t2 starts running (green "U/t" LED flashes at 1.5 Hz). Once time t2 has elapsed, the output relay drops out (yellow "R" LED is OFF). The output relay is controlled in relation to set times t1 and t2 until the supply voltage is interrupted. Time t1 = Pause time Time t2 = Pulse time **==> picture [174 x 61] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>LED R/R<br>t1 t2 t1 t2 t1<br>**----- End of picture text -----**<br> ## **Switched-mode beginning with pulse - Ii** **==> picture [41 x 107] intentionally omitted <==** **----- Start of picture text -----**<br> 15<br>A1 B1<br>A1 15<br>R<br>A2 16 18<br>A2<br>16 18<br>**----- End of picture text -----**<br> Figure 3 Switched-mode beginning with pulse When supply voltage U is applied, the output relay picks up (yellow "R" LED is ON) and set time t1 starts running (green "U/t" LED flashes at 0.75 Hz). Once time t1 has elapsed, the output relay drops out (yellow "R" LED is OFF) and set time t2 starts running (green "U/t" LED flashes at 1.5 Hz). Once time t2 has elapsed, the output relay picks up again (yellow "R" LED is ON). The output relay is controlled in relation to set times t1 and t2 until the supply voltage is interrupted. Time t1 = Pulse time Time t2 = Pause time |**U**<br>**LED U/t**<br>**LED R/R**||||||t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1|t2<br>t2<br>t1<br>t1| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||||||| |||t1||||t2||||||t1||||||t2||||||t1||||||| **PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com** **6 / 6** **106851_en_02**
Updated at June 3, 2026
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →