2907064
Process Indicator, Universal Input, Multifunction, 24 Vac/dc to 230 Vac/dc
- Manufacturer: PHOENIX CONTACT
- Product type: Digital Panel Meters
- No. of Digits / Alpha:5; Meter Function:Current, RTD, Thermocouple, Voltage; Meter Range:0mA to 20mA, 4mA to 20mA, 0V to 10V, -1V to +1V, -10V to +10V, -30V to +30V, -100mV to +10
- SVHC: Lead (04-Feb-2026)
- Meter Range: 0mA to 20mA, 4mA to 20mA, 0V to 10V, -1V to +1V, -10V to +10V, -30V to +30V, -100mV to +10mV
- Digit Height: -
- Product Range: -
- Meter Function: Current, RTD, Thermocouple, Voltage
- Panel Cutout Width: -
- Supply Voltage Max: 230V
- Supply Voltage Min: 24V
- Panel Cutout Height: -
- No. of Digits / Alpha: 5
- Operating Temperature Max: 60°C
- Operating Temperature Min: -20°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 433.5 € |
| Current stock | 10+ |
| Lead time | 30 days |
https://www.phoenixcontact.com/gb/products/2907064 ## Digital display - FA MCR-D-TUI-UI-2REL-UP - 2907064 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Multifunctional process indicator inside the control panel housing for monitoring and displaying analog measurement data. Universal inputs permit connection of current, voltage, RTDs, and TCs. Two relay changeover contact outputs and one analog output. ## Product Description Multifunctional process indicator inside the control panel housing for monitoring and displaying analog measurement data. Dual-conductor sensors can be powered with the integrated measuring transducer supply. Universal inputs permit connection of current, voltage, RTDs, and TCs. Limit values can be monitored and relays can be switched. The analog output allows you to transmit process signals. A color change in the event of a fault supports the detection of alarm conditions. 5-digit, 7-segment LC display, with backlight, 1 universal input, 2 relays, min./max. value memory, linearization table, digital status output (open collector) Key Commercial Data Packing unit 1 STK ~~a~~ GTIN ~~Ds~~ GTIN 4055626204666 ~~LLL eG~~ Weight per Piece (excluding packing) 539.800 g ~~**a** Ge~~ Custom tariff number 90303330 ~~a~~ Country of origin ~~Ge~~ Germany ## Technical data ## Dimensions |Width|96 mm| |---|---| |Height|48 mm| |Depth|151.8 mm| |Ambient conditions|| |Ambient temperature (operation)|-20 °C ... 60 °C| |Ambient temperature (storage/transport)|-40 °C ... 85 °C| |Maximum altitude|< 2000 m (Above sea level)| |Degree of protection|IP65 from the front| ## Ambient conditions 04/17/2018 Page 1 / 6 https://www.phoenixcontact.com/gb/products/2907064 ## Digital display - FA MCR-D-TUI-UI-2REL-UP - 2907064 ## Technical data ## Input data |Input data|| |---|---| |Description of the input|Universal input| |Number of inputs<br>~~a~~|1<br>~~a~~<br>~~C~~| |Current input signal<br>~~a~~|0 mA ... 20 mA +10 %<br>~~a~~<br>~~G~~| |~~GO~~|4 mA ... 20 mA +10 %<br>~~GO~~| |Max. input current<br>~~GO~~|< 150 mA<br>~~GO~~| |Input signal<br>~~GO~~|Current<br>~~GO~~| |Input resistance current input<br>~~GO~~|10 Ω<br>~~GO~~| |Transmitter supply voltage<br>~~a~~|> 16 V (22 mA)<br>~~a~~<br>~~C~~| |Transmitter supply voltage range<br>~~a~~|22.8 V ... 27.6 V (No-load)<br>~~a~~<br>~~G~~| |Transmitter supply current<br>~~GO~~|< 30 mA (Short-circuit and overload protection)<br>~~GO~~| |Available input sources<br>~~GO~~|Resistance thermometers<br>~~GO~~| |Sensor types (RTD) that can be used<br>~~GO~~|Pt, Ni, Cu sensors<br>~~GO~~| |Connection technology<br>~~GO~~|2, 3, 4-wire<br>~~GO~~| |Description of the input<br>~~a~~|Universal input<br>~~a~~<br>~~C~~| |Voltage input signal<br>~~a~~|0 V ... 10 V<br>~~a~~<br>~~G~~| |~~GO~~|2 V ... 10 V<br>~~GO~~| |~~GO~~|0 V ... 5 V<br>~~GO~~| |~~GO~~|0 V ... 1 V<br>~~GO~~| |~~GO~~|1 V ... 5 V<br>~~GO~~| |~~a~~|-1 V ... 1 V<br>~~a~~<br>~~C~~| |~~a~~|-10 V ... 10 V<br>~~a~~<br>~~G~~| |~~GO~~|-30 V ... 30 V<br>~~GO~~| |~~GO~~|-100 mV ... 100 mV<br>~~GO~~| |max. input voltage<br>~~CO~~|± 35 V (≥ 1 V)<br>~~CO~~| |Input signal<br>~~OO~~|Voltage<br>~~OO~~| |Input resistance of voltage input<br>~~a~~|> 1 MΩ<br>~~a~~<br>~~C~~| |Available input sources<br>~~a~~|Thermocouples<br>~~a~~<br>~~G~~| |Sensor types that can be used (TC)<br>~~Ge~~|J, K, T, N, B, S, R, U. L, C, D<br>~~Ge~~| ## Output data 04/17/2018 Page 2 / 6 https://www.phoenixcontact.com/gb/products/2907064 ## Digital display - FA MCR-D-TUI-UI-2REL-UP - 2907064 ## Technical data Output data 2 V ... 10 V 0 V ... 5 V 1 V ... 5 V Max. output voltage < 11 V Ripple < 10 mVPP (1000 Ω) D/A resolution 13 bit Switching output Output name Relay output Contact type 2 PDT Minimum switching voltage 12 V Maximum switching voltage 30 V DC (3 A) 230 V AC (3 A) Min. switching current 10 mA Output name Transistor output, active Output description Open collector output Number of outputs 1 Contact type Transistor Maximum switching voltage 28 V Max. switching current 3 A 200 mA Power supply Supply voltage range 24 V AC/DC ... 230 V AC/DC (-20 % ... +10 %, 50 Hz ... 60 Hz) Power consumption ≤ 6.9 W ~~—_~~ General Test voltage 2500 V Protection class I Overvoltage category II Degree of pollution 2 Test voltage input/output 500 V Test voltage input/power supply 2500 V Test voltage output/power supply 2500 V Noise emission IEC 61326, class A Noise immunity IEC 61326 / NAMUR NE 21 Housing material PC-GF10 Max. viewing angle range +/- 45° from the centre line of the display in Mounting position every direction Conformance CE-compliant UL, USA/Canada UL 61010 Recognized CSA CSA GP GL GL EMC 1 C 04/17/2018 Page 3 / 6 ~~_[=]~~ https://www.phoenixcontact.com/gb/products/2907064 ## Digital display - FA MCR-D-TUI-UI-2REL-UP - 2907064 ## Technical data ## Standards and Regulations |Noise emission|IEC 61326, class A| |---|---| |Noise immunity|IEC 61326 / NAMUR NE 21| |Conformance|CE-compliant| |UL, USA/Canada|UL 61010 Recognized| |CSA|CSA GP| |GL|GL EMC 1 C| Environmental Product Compliance China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values ~~ee~~ Drawings Block diagram **==> picture [166 x 136] intentionally omitted <==** **----- Start of picture text -----**<br> Sensor / FieldPWRIN+ 1.1 IN OUT<br>2-wire<br>US 4-wireOut I-Out I+ 1.41.4 1.1 4.14.2 4.3 +<br>Out I- 2.4 1.2 4.3 Passive<br>US = >1V4-wireOut UOut U-Out U++ 1.32.32.4 1.31.42.1 l 2x e R.12R.114.4 R.12R.114.4 - DI<br>US 4-wire 2.2 R.13 R.13<br>Out U- 2.4 2.3 R.22<br>2.3 2.4 R.21<br>R.22<br>2.4 R.23 R.21 DI<br>2.1 R.23<br>2.22.3 24V...230V AC/DCPower L/+<br>= : 2.4 ET N/-<br>PE<br>e Wi<br>**----- End of picture text -----**<br> Pictogram **==> picture [115 x 121] intentionally omitted <==** **----- Start of picture text -----**<br> POWER U,I U,I<br>OUT<br>IN<br>2x<br>POWER<br>©2<br>Zs<br>**----- End of picture text -----**<br> ## Classifications ## eCl@ss |eCl@ss|| |---|---| |eCl@ss 4.0|27210301| |eCl@ss 4.1|27210301| |eCl@ss 5.0|27210301| |eCl@ss 5.1|27210301| |eCl@ss 6.0|27210301| |eCl@ss 7.0|27210301| |eCl@ss 8.0|27210301| |eCl@ss 9.0|27210301| 04/17/2018 Page 4 / 6 https://www.phoenixcontact.com/gb/products/2907064 ## Digital display - FA MCR-D-TUI-UI-2REL-UP - 2907064 ## Classifications ETIM ETIM 4.0 EC001426 ETIM 5.0 EC001426 ETIM 6.0 EC001426 ~~———~~ ## Approvals Approvals ## Approvals UL Recognized / cUL Recognized / CSA / DNV GL / cULus Recognized Ex Approvals ## Approval details UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 198586 > cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 198586 ~~ee~~ CSA http://www.csagroup.org/services-industries/product-listing/ 2879105 ~~oo~~ DNV GL http://exchange.dnv.com/tari/ 42233-15 HH > cULus Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm ~~oo~~ Accessories Accessories Programming adapter 04/17/2018 Page 5 / 6 https://www.phoenixcontact.com/gb/products/2907064 ## Digital display - FA MCR-D-TUI-UI-2REL-UP - 2907064 ## Accessories Programming adapter - MCR-PAC-T-USB - 2309000 Programming adapter with USB and T port interface, 2.4 m for programming FA MCR-..., MCR-...-LP-..., and MCR-...HT-... modules Phoenix Contact 2018 © - all rights reserved http://www.phoenixcontact.com 04/17/2018 Page 6 / 6
Updated at June 9, 2026
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →