2905141
MOTOR STARTER, 3PH, 0.6A, 19.2-30VDC
- Manufacturer: PHOENIX CONTACT
- Product type: Motor Starters
- SVHC: Lead (21-Jan-2025)
- No. of Poles: -
- Power Rating: 2.5W
- No. of Phases: Three Phase
- Product Range: ELR
- Current Rating: 600mA
- IP / NEMA Rating: IP20
- Motor Starter Type: Hybrid Motor Starter
- Supply Voltage Max: 30VDC
- Supply Voltage Min: 19.2VDC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 189.48 € |
| Current stock | 10+ |
| Lead time | 30 days |
https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 0.6 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided. ## Your advantages - 22.5 mm wide - Safety level according to IEC 61508-1: SIL 3, ISO 13849: PL e - Reduction in wiring - Space saving - Long service life - 3-phase loop bridges - Adjustable current for bimetal function - Low-wear switching ## Key Commercial Data **==> picture [374 x 217] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Packing unit|1 pc| |GTIN| |GTIN|4046356920490| |Weight per Piece (excluding packing)|285.700 g| |Custom tariff number|85371098| |Country of origin|Germany| |Note|Made to Order (non-returnable)| |Technical data| |Dimensions| |Width|22.5 mm| |Height|107.5 mm| |Depth|114 mm| **----- End of picture text -----**<br> ## Technical data ## Dimensions Ambient conditions 12/30/2019 Page 1 / 12 https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 ## Technical data Ambient conditions |Ambient conditions|Ambient conditions| |---|---| |Ambient temperature (operation)<br>-5 °C ... 60 °C (observe derating)<br>Ambient temperature (storage/transport)<br>-40 °C ... 80 °C<br>Maximum altitude<br>≤ 2000 m<br>Degree of protection<br>IP20<br>~~SSS~~|| |Device supply|| |Rated control circuit supply voltage US|24 V DC| |Control supply voltage range|19.2 V DC ... 30 V DC| |Rated control supply current IS|60 mA| |Type of protection|Surge protection| ||Reverse polarity protection| ## Input data |Input name|Enable input| |---|---| ||The enable input is compatible with signals with blanking (semiconductor| |Note|output signals with test pulse with max. 3 ms duration),<br>unblanking pulses of max. 4 ms are tolerated without adversely| ||affecting the safety function.| |Rated actuating voltage UC|24 V DC| |Triggering voltage range|19.2 V DC ... 30 V DC| |Rated actuating current IC|7 mA| |Switching threshold|9.6 V (“0” signal)| ||19.2 V (“1” signal)| |Switching level|< 5 V DC (For EMERGENCY STOP)| |Typical turn-off time|< 30 ms| |Type of protection|Reverse polarity protection| |Output data load output|| |Output name|AC output| |Rated operating voltage Ue|500 V AC| |Operating voltage range|42 V AC ... 550 V AC| |Rated operating current Ie|0.6 A (AC-51)| ||0.6 A (AC-53a)| |Mains frequency|50/60 Hz| |Load current range|75 mA ... 600 mA (see to derating)| |Trigger characteristic in acc. with IEC 60947-4-2|Class 10| |Cooling time|20 min. (for auto reset)| |Leakage current|0 mA| |Type of protection|Surge protection| |Overspeed tripping|| |Operate threshold|> 10 A| |Response time|< 0.5 s| 12/30/2019 Page 2 / 12 https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 ## Technical data ## General |General|| |---|---| |Motor starter type|Direct starter| |Switching frequency|≤ 2 Hz (Load-dependent)| |Mounting position|vertical (horizontal DIN rail, motor output below)| |Mounting type|DIN rail mounting| |Assembly instructions|alignable, for spacing see derating| |Operating mode|100% operating factor| |Maximum power dissipation|2.5 W| |Minimum power dissipation|0.88 W| |Operating voltage display|Green LED| |Status display|Yellow LED| |Indication|Red LED| |Connection data|| |Connection name<br>Control circuits<br>Connection method<br>Push-in connection<br>Stripping length<br>10 mm<br>Conductor cross section solid<br>0.2 mm² ... 2.5 mm²<br>Conductor cross section flexible<br>0.2 mm² ... 2.5 mm²<br>Conductor cross section AWG<br>24 ... 14<br>~~=~~|| |Connection data 2|| |Connection name<br>Load circuit<br>Connection method<br>Push-in connection<br>Stripping length<br>10 mm<br>Conductor cross section solid<br>0.2 mm² ... 2.5 mm²<br>Conductor cross section flexible<br>0.2 mm² ... 2.5 mm²<br>Conductor cross section AWG<br>24 ... 14<br>~~SS~~|| |Insulation characteristics|| |Rated insulation voltage|550 V| |Rated surge voltage|6 kV| |Overvoltage category|III| |Degree of pollution|2| |Designation|Insulation characteristics between the control input and control supply<br>voltage, and auxiliary circuit to the main circuit| |Insulation|Safe isolation (IEC 60947-1)| |Designation|Isolation characteristics between the control input and control supply<br>voltage to auxiliary circuit| |Insulation|Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC| ||Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC| |Standards and Regulations|| |Designation|Standards/regulations| |Standards/regulations|IEC 60947-1| 12/30/2019 Page 3 / 12 https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 ## Technical data Standards and Regulations EN 60947-4-2 IEC 61508 ISO 13849 ## Conformance/approvals **==> picture [522 x 487] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Designation|ATEX| |Identification| II (2) G [Ex eb] [Ex db] [Ex pxb]| | II (2) D [Ex tb] [Ex pb]| |Certificate|PTB 15 ATEX 3000| |Designation|UL approval| |Certificate|NLDX.E228652| |NRNT.E172140| |Designation|Safety Integrity Level (SIL, IEC 61508)| |Identification|≤ 3| |Additional text|Safe shutdown| |Designation|Safety Integrity Level (SIL, IEC 61508)| |Identification|2| |Additional text|Motor protection| |Designation|Performance Level (ISO 13849)| |Identification|e| |Additional text|Safe shutdown| |Designation|Category (ISO 13849)| |Identification|≤ 3| |Additional text|Safe shutdown| |UL data| |SCCR|100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))| |5 kA (480 V AC (fuse: 20 A RK5 (standard fault)))| |FLA|0.6 A (480 V AC)| |20 A (class RK5, SCCR 5kA (480 V AC), 24 - 14 AWG max. solid and| |Group installation| |stranded)| |30 A (class CC or J, SCCR 100kA (480 V AC), 24 - 14 AWG max, solid| |and stranded)| |Category code|NLDX / NRNT| |-| |Horsepower ratings| |Environmental Product Compliance| |REACh SVHC|Lead 7439-92-1| |China RoHS|Environmentally Friendly Use Period = 50| |For details about hazardous substances go to tab “Downloads”,| |Category “Manufacturer's declaration”| **----- End of picture text -----**<br> ## Drawings 12/30/2019 Page 4 / 12 https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 Block diagram **==> picture [35 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Diagram<br>**----- End of picture text -----**<br> Derating diagram ## Classifications ## eCl@ss |eCl@ss 4.0|eCl@ss 4.0|27021100| |---|---|---| |eCl@ss 4.1|eCl@ss 4.1|27021100| |eCl@ss 5.0|eCl@ss 5.0|27024000| |eCl@ss 5.1|eCl@ss 5.1|27024000| |eCl@ss 6.0|eCl@ss 6.0|27024000| |eCl@ss 7.0|eCl@ss 7.0|27024002| 12/30/2019 Page 5 / 12 https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 ## Classifications |eCl@ss|| |---|---| |eCl@ss 8.0<br>~~ee~~|27024002<br>~~ee~~| |eCl@ss 9.0<br>~~ee~~|27370905<br>~~ee~~| ## ETIM |ETIM 2.0|ETIM 2.0|EC001037| |---|---|---| |ETIM 3.0|ETIM 3.0|EC001037| |ETIM 4.0|ETIM 4.0|EC001037| |ETIM 5.0|ETIM 5.0|EC001037| |ETIM 6.0|ETIM 6.0|EC001037| |ETIM 7.0|ETIM 7.0|EC001037| ## UNSPSC |UNSPSC 13.2|UNSPSC 13.2|25173902| |---|---|---| |UNSPSC 18.0|UNSPSC 18.0|25173902| |UNSPSC 19.0|UNSPSC 19.0|25173902| |UNSPSC 20.0|UNSPSC 20.0|25173902| |UNSPSC 21.0|UNSPSC 21.0|25173902| ## Approvals ## Approvals ## Approvals UL Listed / cUL Listed / UL Listed / IECEE CB Scheme / cUL Listed / VDE Zeichengenehmigung / CCC / EAC Ex Approvals ATEX Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 228652 ~~oo~~ cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 228652 UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 172140 ~~ee~~ 12/30/2019 Page 6 / 12 https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 Approvals IECEE CB Scheme http://www.iecee.org/ DE1-60807 ~~oo~~ cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 172140 http://www2.vde.com/de/Institut/Online-Service/ VDE Zeichengenehmigung 40048671 VDE-gepruefteProdukte/Seiten/Online-Suche.aspx ~~ee~~ CCC 2016010304900298 ~~oo~~ RU C- EAC DE.A*30.B.01082 ~~oo~~ Accessories Accessories Cover Covering hood - BRIDGE COVER - 2906240 The BRIDGE COVER covering hood is used to cover unused plugs on the CONTACTRON bridge that may subsequently be used to extend the system. The hood can be used with the screw and Push-in version of the bridge. ## Device marking Plastic label - US-EMLP (15X5) - 0828790 Plastic label, Card, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 189 12/30/2019 Page 7 / 12 https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 ## Accessories Plastic label - UC-EMLP (15X5) - 0819301 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 10 ## DIN rail connector DIN rail bus connectors - ME 22,5 TBUS 1,5/ 5-ST-3,81 GY - 2201937 DIN rail connector, number of positions: 5, pitch: 3.81 mm DIN rail bus connectors - ME 22,5 TBUS ADAPTER KMGY - 2201756 DIN rail bus adapter for ME and ME-MAX, design width: 22.5 mm, 5 parallel positions, color: light gray (similar to RAL 7035) ## Extension module Extension module - EM-D-8/4-24DC-IFS - 2904473 For more complex applications with Interface system devices (IFS), the extension module offers digital inputs and outputs for processing additional signals in the field. Easy connection to IFS gateway via the DIN rail connector as the slave. ## Gateways/Proxies Data interface - EM-PB-GATEWAY-IFS - 2297620 Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via PROFIBUS DP. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. 12/30/2019 Page 8 / 12 https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 ## Accessories Data interface - EM-ETH-GATEWAY-IFS - 2901988 Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via EtherNet/IP™. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. ## Data interface - EM-PNET-GATEWAY-IFS - 2904472 Gateway for the connection of up to 32 INTERFACE system devices via PROFINET to a higher-level controller. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. Data interface - EM-CAN-GATEWAY-IFS - 2901504 Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via CANopen®. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. 1] Data interface - EM-RS232-GATEWAY-IFS - 2901526 Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via Modbus/RS-232. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. ~~OO~~ Data interface - EM-RS485-GATEWAY-IFS - 2901527 Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via Modbus/RS-485. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. ~~OO~~ 12/30/2019 Page 9 / 12 https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 ## Accessories Data interface - EM-MODBUS-GATEWAY-IFS - 2901528 Gateway for the connection of up to 32 INTERFACE system devices via Modbus/TCP to a higher-level controller. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. ## Data interface - EM-DNET-GATEWAY-IFS - 2901529 Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via DeviceNet™. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. ## Loop bridge Jumper - BRIDGE-PT 2 - 2904490 3-phase loop bridge for 2 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting ~~Pm~~ cable: 3 m, with ferrules included. Jumper - BRIDGE-PT 3 - 2904491 3-phase loop bridge for 3 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting ~~nm~~ cable: 3 m, with ferrules included. Jumper - BRIDGE-PT 4 - 2904492 3-phase loop bridge for 4 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting ~~nm~~ cable: 3 m, with ferrules included. 12/30/2019 Page 10 / 12 https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 ## Accessories Jumper - BRIDGE-PT 5 - 2904493 3-phase loop bridge for 5 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting ~~Om~~ cable: 3 m, with ferrules included. Jumper - BRIDGE-PT 6 - 2904494 3-phase loop bridge for 6 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting ~~Om~~ cable: 3 m, with ferrules included. Jumper - BRIDGE-PT 7 - 2904495 3-phase loop bridge for 7 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included. Jumper - BRIDGE-PT 8 - 2904496 3-phase loop bridge for 8 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included. Jumper - BRIDGE-PT 9 - 2904497 3-phase loop bridge for 9 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included. 12/30/2019 Page 11 / 12 https://www.phoenixcontact.com/gb/products/2905141 ## Hybrid motor starter - ELR H3-IES-PT/500AC-06-IFS - 2905141 ## Accessories Jumper - BRIDGE-PT 10 - 2904498 3-phase loop bridge for 10 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included. Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com 12/30/2019 Page 12 / 12
Updated at April 29, 2026
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →