2900414
Motor Starter, Hybrid, ELR H5 Series, Three Phase, 40 mA, 24 Vdc
- Manufacturer: PHOENIX CONTACT
- Product type: Motor Starters
- Supply Voltage Min:19.2VDC; Supply Voltage Max:30VDC; No. of Phases:Three Phase; Power Rating:-; Current Rating:40mA; Product Range:ELR H5 Series; SVHC:No SVHC (15-Jan-2019)
- SVHC: Lead (04-Feb-2026)
- No. of Poles: -
- Power Rating: 3.3W
- No. of Phases: Three Phase
- Product Range: ELR
- Current Rating: 40mA
- IP / NEMA Rating: IP20
- Motor Starter Type: Hybrid Motor Starter
- Supply Voltage Max: 30VDC
- Supply Voltage Min: 19.2VDC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 163.13 € |
| Current stock | 10+ |
| Lead time | 30 days |
https://www.phoenixcontact.com/gb/products/2900414
## Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download)
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3 / PL e and screw connection
## Why buy this product
- 22.5 mm wide
Safety level according to IEC 61508-1: SIL 3, ISO 13849: PL e
- Reduction in wiring
- Long service life
- Space saving 3-phase loop bridges
Adjustable current for bimetal function
Low-wear switching
## Key Commercial Data
~~ee~~ Packing unit 1 STK GTIN ~~A~~ GTIN 4046356504058 ~~ee nN~~ Weight per Piece (excluding packing) 269.600 g ~~ee~~ Custom tariff number 85371098 ~~nN~~ Country of origin Germany
## Technical data
## Device supply
|Device supply||
|---|---|
|Rated control circuit supply voltage US|24 V DC|
|Control supply voltage range|19.2 V DC ... 30 V DC|
|Rated control supply current IS|40 mA|
|Type of protection|Surge protection|
||Reverse polarity protection|
04/16/2018 Page 1 / 13
https://www.phoenixcontact.com/gb/products/2900414
## Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414
## Technical data
## Input data
Input name Control input right/left Rated actuating voltage UC 24 V DC Triggering voltage range 19.2 V DC ... 30 V DC Rated actuating current IC 5 mA (Input type 1) Switching threshold 9.6 V (“0” signal) 19.2 V (“1” signal) Switching level < 5 V DC (For EMERGENCY STOP) Typical turn-off time < 30 ms Type of protection Reverse polarity protection Output data load output Output name AC output Rated operating voltage Ue 500 V AC Operating voltage range 42 V AC ... 550 V AC Rated operating current Ie 2.4 A (AC-51) 2.4 A (AC-53a) Mains frequency 50/60 Hz Load current range 180 mA ... 2.4 A (see to derating) Trigger characteristic in acc. with IEC 60947-4-2 Class 10A Cooling time 20 min. (for auto reset) Leakage current 0 mA Type of protection Surge protection ~~———=~~ Output data reply output Output name Acknowledge output Note Confirmation: floating change-over contact, signal contact Contact type 1 PDT Switching capacity according to IEC 60947-5-1 3 A (230 V, AC15) 2 A (24 V, DC13) ~~SSS~~ General Switching frequency ≤ 2 Hz (Load-dependent) Mounting position vertical (horizontal DIN rail, motor output below) Mounting type DIN rail mounting Assembly instructions alignable, for spacing see derating Operating mode 100% operating factor Maximum power dissipation 4.1 W Minimum power dissipation 0.88 W Operating voltage display Green LED Status display Yellow LED Indication Red LED ~~—J~~ Connection data, input side 04/16/2018 Page 2 / 13
https://www.phoenixcontact.com/gb/products/2900414
## Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Technical data Connection data, input side Connection name Control circuits Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm ~~=~~ Connection data, output side Connection name Load circuit Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm Ambient conditions Ambient temperature (operation) -25 °C ... 70 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 80 °C Degree of protection IP20 ~~_——~~ Dimensions Width 22.5 mm Height 106.6 mm Depth 113.7 mm UL data SCCR 100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) 5 kA (500 V AC (fuse: 20 A RK5 (standard fault))) FLA 2.4 A (500 V AC) Group installation 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) Category code NLDX Insulation characteristics ~~==~~ Rated insulation voltage 500 V ~~SS~~ Rated surge voltage 6 kV Overvoltage category III Degree of pollution 2 ~~SSS~~
04/16/2018 Page 3 / 13
https://www.phoenixcontact.com/gb/products/2900414
## Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414
## Technical data
Insulation characteristics Insulation characteristics between the control input and control supply Designation voltage, and auxiliary circuit to the main circuit Insulation Safe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC Isolation characteristics between the control input and control supply Designation voltage to auxiliary circuit Insulation Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC ~~=~~ Standards and Regulations Designation Standards/regulations Standards/regulations IEC 60947-1 IEC 60947-4-2 IEC 61508 ISO 13849 ATEX # II (2) G [Ex e] [Ex d] [Ex px] # II (2) D [Ex t] [Ex p] ~~===>~~ Approvals/conformities Safety Integrity Level according to IEC 61508 ≤ 3 (Safe shutdown) 2 (Motor protection) Category acc. to EN ISO 13849 ≤ 3 (Safe shutdown) Performance level according to ISO 13849 ≤ e (Safe shutdown) ATEX # II (2) G [Ex e] [Ex d] [Ex px] # II (2) D [Ex t] [Ex p] EU-type examination certificate PTB 07 ATEX 3145 UL certificate NLDX.E228652 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
## Drawings
04/16/2018 Page 4 / 13
https://www.phoenixcontact.com/gb/products/2900414
## Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414
**==> picture [433 x 370] intentionally omitted <==**
**----- Start of picture text -----**<br>
Diagram Block diagram<br>9 MAN RES 1/L1 3/L2 5/L3<br>8 +) RES © Logic<br>7<br>6 AUTO µP<br>5<br>43 Us<br>2 T<br>0,181 jee T E can e A N<br>0 10 20 30 40 50 60 70<br>Ambient temperature [°C] R<br>= aligned with > 20 mm spacing<br>$ = aligned without spacing L og 000 97 96 95 2/T1 OOO 4/T2 6/T3<br>Circuit diagram Circuit diagram<br>L1L2L3 F1F2F3 F5 K5 K5<br>F4 S2<br>K1<br>K2 yy T1 & q - K l 5 et K t 5<br>K5<br>T2 T3<br>K3 K4<br>K1<br>K4 K3 K5 K5<br>K2<br>F4<br>M K3 K4 K5 K5 K1 K2<br>3 ~<br>UI {<br>M1 _ PE GND<br>Load current[A]<br>**----- End of picture text -----**<br>
Derating diagram
Conventional structure Main current path for reversing contactor according to category 3
K1 + K2 = Emergency stop contactor K3 = Left contactor K4 = Right contactor F4 = Motor protection relay
Conventional structure Control current path reversing contactor according to category 3
K1 + K2 = Emergency stop contactor K3 = Left contactor K4 = Right contactor K5 = PSR SCP-24DC.../Safety relay T1 = Right, T2 = Left, T3 = Reset S2 = Emergency stop F4 = Motor protection relay
04/16/2018 Page 5 / 13
https://www.phoenixcontact.com/gb/products/2900414
## Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414
## Circuit diagram
**==> picture [174 x 191] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 F1<br>L2L3 F2F3<br>K5<br>L1 L2 L3 T3<br>K1<br>T1 T2 T3 T1 T2<br>K5<br>M K1 +US R L K5 S2 K5 K5<br>3 ~ E<br>M1 al PE ret f<br>K5 K5<br>K5<br>GND<br>**----- End of picture text -----**<br>
## Structure with CONTACTRON
Main and control current path for ,4 in 1, hybrid motor starter with reversing function according to category 3 K1 = ,4 in 1, hybrid motor starter with reversing function K5 = PSR SCP-24DC.../Safety relay T1 = Right, T2 = Left, T3 = Reset S2 = Emergency stop
## Classifications
## eCl@ss
|eCl@ss 5.0|eCl@ss 5.0|27024002|
|---|---|---|
|eCl@ss 5.1|eCl@ss 5.1|27024002|
|eCl@ss 6.0|eCl@ss 6.0|27024002|
|eCl@ss 7.0|eCl@ss 7.0|27024002|
|eCl@ss 8.0|eCl@ss 8.0|27024002|
|eCl@ss 9.0|eCl@ss 9.0|27024002|
## ETIM
|ETIM 2.0|ETIM 2.0|EC001037|
|---|---|---|
|ETIM 3.0|ETIM 3.0|EC001037|
|ETIM 4.0|ETIM 4.0|EC001037|
|ETIM 5.0|ETIM 5.0|EC001037|
|ETIM 6.0|ETIM 6.0|EC001037|
## UNSPSC
|UNSPSC 6.01|UNSPSC 6.01|30211915|
|---|---|---|
|UNSPSC 7.0901|UNSPSC 7.0901|39121514|
|UNSPSC 11|UNSPSC 11|39121514|
|UNSPSC 12.01|UNSPSC 12.01|39121514|
04/16/2018 Page 6 / 13
https://www.phoenixcontact.com/gb/products/2900414
## Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414
## Classifications
## UNSPSC
UNSPSC 13.2 25173902
## Approvals
## Approvals
## Approvals
UL Listed / cUL Listed / IECEE CB Scheme / GL / GL-SW / UL Listed / cUL Listed / EAC / EAC / CCC-s / cULus Listed / GL
Ex Approvals
ATEX Approval details
UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 323771 ~~ee~~ cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 323771 ~~oo~~ IECEE CB Scheme http://www.iecee.org/ DE1-55728 GL http://exchange.dnv.com/tari/ 54757-08 HH ~~ee~~ GL-SW 54757-08 HH UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 228652 ~~ee~~ cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 228652 ~~oo~~
04/16/2018 Page 7 / 13
https://www.phoenixcontact.com/gb/products/2900414
## Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Approvals
|EAC<br><br>EAC-Zulassung<br>~~oo~~|EAC<br><br>EAC-Zulassung<br>~~oo~~|EAC<br><br>EAC-Zulassung<br>~~oo~~|EAC<br><br>EAC-Zulassung<br>~~oo~~|
|---|---|---|---|
||EAC||RU C-<br>DE.A*30.B.01082|
|||||
||CCC-s|http://www.china-certification.com|2016010304871315|
|||||
||cULus Listed|||
|||||
||GL|http://www.gl-group.com/newbuilding/approvals/index.html||
Accessories
Accessories Bridge
Jumper - BRIDGE- 4-3M - 2901659
3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.
Cover
Covering hood - BRIDGE COVER - 2906240 The BRIDGE COVER covering hood is used to cover unused plugs on the CONTACTRON bridge that may subsequently be used to extend the system. The hood can be used with the screw and Push-in version of the bridge. ~~So~~
Device marking
04/16/2018 Page 8 / 13
https://www.phoenixcontact.com/gb/products/2900414
## Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414
## Accessories
Plastic label - US-EMLP (15X5) - 0828790
Plastic label, Card, white, unlabeled, can be labeled with: THERMOMARK PRIME, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm
Plastic label - UC-EMLP (15X5) - 0819301
Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED, CMS-P1PLOTTER, PLOTMARK, mounting type: adhesive, lettering field size: 15 x 5 mm
## Loop bridge
Jumper - BRIDGE- 2 - 2900746
3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.
##
3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.
##
3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.
04/16/2018 Page 9 / 13
https://www.phoenixcontact.com/gb/products/2900414
Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414 Accessories Jumper - BRIDGE- 5 - 2900749 3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules. ~~ee~~ Jumper - BRIDGE- 6 - 2900750 3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules. ~~ee~~ Jumper - BRIDGE- 7 - 2900751 3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules. ~~ee~~ Jumper - BRIDGE- 8 - 2900752 3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules. ~~ee~~ Jumper - BRIDGE- 9 - 2900753 3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules. ~~ee~~ 04/16/2018 Page 10 / 13
https://www.phoenixcontact.com/gb/products/2900414
Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414 Accessories Jumper - BRIDGE-10 - 2900754 3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules. ~~on~~ Jumper - BRIDGE- 2-3M - 2901543 3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included. ~~Oe~~ Jumper - BRIDGE- 3-3M - 2901656
3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.
Jumper - BRIDGE- 5-3M - 2901545
3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.
Jumper - BRIDGE- 6-3M - 2901697
3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.
04/16/2018 Page 11 / 13
https://www.phoenixcontact.com/gb/products/2900414
## Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414
## Accessories
Jumper - BRIDGE- 7-3M - 2901698
3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included. ~~eo~~ Jumper - BRIDGE- 8-3M - 2901700 3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included. ~~eo~~ Jumper - BRIDGE- 9-3M - 2901701 3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.
Jumper - BRIDGE-10-3M - 2901702
3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.
Jumper - BRIDGE- 2-1M - 2901542
3-phase loop bridge for 2 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules.
04/16/2018 Page 12 / 13
https://www.phoenixcontact.com/gb/products/2900414
## Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-2 - 2900414
## Accessories
Jumper - BRIDGE- 3-1M - 2901655
3-phase loop bridge for 3 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules. ~~we~~ Jumper - BRIDGE- 4-1M - 2901658 3-phase loop bridge for 4 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules. ~~A~~ Jumper - BRIDGE- 5-1M - 2901544 3-phase loop bridge for 5 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules. ~~”~~ Jumper - BRIDGE- 6-1M - 2901649 3-phase loop bridge for 6 modules in the CONTACTRON family with 1 m long connecting cable without ferrules, 22.5 mm housing width.
Phoenix Contact 2018 © - all rights reserved http://www.phoenixcontact.com
04/16/2018 Page 13 / 13
Updated at April 29, 2026
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →