2900312.
Power Relay, SPST-NO, 24 VDC, 6 A, PLC-INTERFACE Series, DIN Rail, Non Latching
- Manufacturer: PHOENIX CONTACT
- Product type: Power Relays
- Contact Configuration:SPST-NO; Coil Voltage:24VDC; Contact Current:6A; Product Range:PLC Series; Relay Mounting:DIN Rail; Coil Type:Non Latching; Contact Voltage VAC:250V; Relay
- SVHC: Hexahydromethylphthalic anhydride [1], Hexahydro-4-methylphthalic anhydride [2], Hexahydro-1-methylphthalic anhydride[3] (04-Feb-2026)
- Coil Type: Non Latching
- Coil Voltage: 24VDC
- Product Range: PLC-INTERFACE Series
- Relay Mounting: DIN Rail
- Coil Resistance: -
- Contact Current: 6A
- Relay Terminals: Quick Connect
- Contact Material: Silver Tin Oxide
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 250V
- Approvals & Standards: UL
- Contact Configuration: SPST-NO
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 11.76 € |
| Current stock | 10+ |
| Lead time | 30 days |
**|** 06/2018 ## › **Logic Controller Millenium Evo** - › **Up to 44 I/Os - 16 DI (4 HighSpeed / 8 AI) - 8 DO** - › **Wireless programming & Control with bluetooth Interface and Crouzet Virtual Display** - › **Modbus RTU Network (Slave)** - › **Local datalog management** › **Up to 1000 programing blocks with** _XBP24 XBP24-E XDP24 XDP24-E_ **intuitive Crouzet Soft to go from** _Base 24 I/O Base 24 I/O Ethernet Base 24 I/O Base 24 I/O Ethernet_ **simple to complex applications** |**Product selection**||||||| |---|---|---|---|---|---|---| |**LCD display**|**Ethernet network**|||**Part number**||| |No|No||||**88 975 001**|| |No|Yes||||**88 975 011**|| |Yes|No||||**88 975 101**|| |Yes|Yes||||**88 975 111**|| |||||||| |**Product selection KIT**||||||| |Bluetooth Kit (Millenium EVO Ethernet 88 975 111, Bluetooth interface 88 980 112,<br>Bluetooth receiver 88 980 116)|||||**88 975 911**|| |Bluetooth Kit (Millenium EVO Standalone 88 975 101, Bluetooth interface 88 980 112,<br>Bluetooth receiver 88 980 116)|||||**88 975 901**|| ||**XBP24**<br>**XBP24-E**<br>~~esRe~~||**XDP24**|||**XDP24-E**| |**General characteristics**||||||| |**Part number**|**88 975 001**<br>**88 975 011**||**88 975 101**|||**88 975 111**| |Products certification|CE, cULus Listed|||||| |Conformity with the low voltage directive|IEC/EN 61131-2 (Open equipment)|||||| |(in accordance with 2014/35/EU)||||||| |Conformity with the EMC directive|IEC/EN 61000-6-1 (Residential, commercial and light-industrial environments)|||||| |(in accordance with 2014/30/EU)|IEC/EN 61000-6-2 (Industrial)|||||| ||IEC/EN 61000-6-3 (Residential, commercial and light-industrial environments)|||||| ||IEC/EN 61000-6-4 (Industrial)|||||| |Power supply earthing|None|||||| |Overvoltage category|3 in accordance with IEC/EN 60664-1|||||| |Pollution|Degree : 2 in accordance with IEC/EN 61131-2|Degree : 2 in accordance with IEC/EN 61131-2||||| |Maximum utilization altitude|Operation: 2000 m|||||| ||Transport: 3000 m|||||| |Mechanical resistance|Immunity to vibrations IEC/EN 60068-2-6, Fc test|||||| ||Immunity to shock IEC/EN 60068-2-27, Ea test|||||| |Resistance to electrostatic discharge|Immunity to ESD IEC/EN 61000-4-2, level 3|||||| |Resistance to HF interference|Immunity to radiated electrostatic fields IEC/EN 61000-4-3, level 3|||||| |(Immunity)|Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3||||Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3|| ||Immunity to shock waves IEC/EN 61000-4-5|||||| ||Radio frequency in common mode IEC/EN 61000-4-6, level 3|||||| |Conducted and radiated emissions|Class B|||||| |(in accordance with EN 55022/11 group 1)||||||| |Operation temperature|-20 °C (-4 °F) → +60 °C (140 °F) (+40 °C (104 °F) in a non-ventilated enclosure)|-20 °C (-4 °F) → +60 °C (140 °F) (+40 °C (104 °F) in a non-ventilated enclosure)||||| ||UL: maximum surrounding air: +50 °C (122 °F)|UL: maximum surrounding air: +50 °C (122 °F)||||| |Standard product<br>||Product made to order<br>.|Contact us||||| **|** AUTOMATION.CROUZET.COM **| 2** **|** Logic Controller **|** 06/2018 **==> picture [495 x 678] intentionally omitted <==** **----- Start of picture text -----**<br> XBP24 XBP24-E XDP24 XDP24-E<br>Storage temperature -40°C (-40 °F) → +80°C (176 °F)<br>Relative humidity 95% max. (no condensation or dripping water)<br>Screw terminals connection capacity Flexible wire with ferrule: 1 conductor: 0.2 to 2.5 mm2 (AWG 24-14)<br>Flexible wire with ferrule: 2 conductors: 0.2 to 0.75 mm2 (AWG 24-18)<br>Rigid wire: 1 conductor: 0.2 to 2.5 mm2 (AWG 24-14)<br>Rigid wire: 2 conductors: 0.2 to 0.75 mm2 (AWG 24-18)<br>Tightening torque: 0.5 N.m (4.5 lb-in) (tighten using screwdriver diam. 3.5 mm)<br>Stripping length: 6 mm<br>Material Lexan, UL94V0<br>Environnement Reach, RoHS, Halogen free 1272/2008/CE<br>On front panel color Grey RAL 7035<br>On sole color Black RAL 9011<br>Protection rating IP 40 on front panel<br>(in accordance with IEC/EN 60529) IP 20 on terminal block<br>Weight Without packing: 270 g Without packing: 300 g Without packing: 330 g<br>With packing: 320 g With packing: 350 g With packing: 380 g<br>Dimensions Without packing: Without packing:<br>124.6 x 90 x 61.1 mm / 4.91 x 3.54 x 2.4 inch 124.6 x 90 x 62 mm / 4.91 x 3.54 x 2.44 inch<br>With packing: With packing:<br>148 x 103 x 65 mm / 5.83 x 4.06 x 2.56 inch 148 x 103 x 65 mm / 5.83 x 4.06 x 2.56 inch<br>Processing characteristics<br>LCD display Without Display with 4 lines of 18 characters, yellow/<br>green<br>Programming method FBD (Function Block Diagram), including SFC (Sequential Function Chart) (Grafcet)<br>Program size Function blocks: typically 512 blocks<br>Macro blocks: 127 max. (255 blocks per macro)<br>Program memory Flash<br>Removable memory N.A<br>Data memory 2 k octets<br>Back-up time Program and settings in the controller: 10 years<br>(in the event of power failure) Data memory: 10 years<br>Data back-up Data backup in the flash memory is guaranteed if the product is powered on more than 10 seconds<br>Cycle time From 2 ms* to 90 ms, default value: 10 ms<br>*: Depending on configuration<br>Clock data retention 10 years (lithium battery) at 25°C (77°F)<br>Clock drift Drift < 12 min/year (at 25°C (77°F))<br>6 s / month (at 25°C (77°F) with user-definable correction of drift).<br>Synchronizable by network<br>Timer block accuracy 0.5 % ± 2 cycle time<br>Start up time on power up < 8 s base alone, < 5 s < 10 s base alone, < 5 < 8 s base alone, < 5 s < 10 s base alone, < 5<br>base + 2 expansions + s base + 2 expansions base + 2 expansions + s base + 2 expansions<br>1 accessory (RS485) + 1 accessory (RS485) 1 accessory (RS485) + 1 accessory (RS485)<br>Self test Test firmware integrity (checksum memory)<br>Stability of the internal power supply<br>Check the conformity of the em4 device configuration with the configuration in the application<br>program.<br>Supply<br>Nominal voltage 24 VDC (-15% / +20%)<br>Operating limits 20.4 - 28.8 VDC<br>Immunity from micro power cuts ≤ 1 ms (repetition 20 times)<br>Max. absorbed power 3.8 W @ 24 VDC, 5 W 4.8W @ 24 VDC, 6.2 4W @ 24 VDC, 5.3 W 5W @ 24 VDC, 6.5 W<br>@ 28.8 VDC, W @ 28.8 VDC, @ 28.8 VDC, - 0.3 W @ 28.8 VDC, - 0.3 W<br>1.5 W @ 24 VDC I/O 1.5W @ 24 VDC I/O backlight OFF backlight OFF<br>OFF OFF 1.5W @ 24 VDC (I/O 1.5W @ 24 VDC (I/O<br>+ backlight) OFF + backlight) OFF<br>**----- End of picture text -----**<br> **|** AUTOMATION.CROUZET.COM **| 3** **|** Logic Controller **|** 06/2018 |**XBP24**<br>**XBP24-E**<br>**XDP24**<br>**XDP24-E**<br>Protection against polarity inversions<br>Yes|**XBP24**<br>**XBP24-E**<br>**XDP24**<br>**XDP24-E**<br>Protection against polarity inversions<br>Yes| |---|---| |Power monitoring<br>Yes and value available through the application «FB Status», 1/10V, 5%.|| |**Inputs**|| |**Digital and high speed digital inputs 24 VDC - 4 inputs from I1 to I4**|| |**Input used as digital input**|| |Input voltage<br>24 VDC (-15% / +20%)|| |Input current<br>1.8 mA @ 20.4 V<br>2.1 mA @ 24 V<br>2.5 mA @ 28.8 V|| |Input impedance<br>11.6 kΩ|| |Logic 1 voltage threshold<br>≥ 15 VDC|| |Making current at logic state 1<br>≥ 1.3 mA|| |Logic 0 voltage threshold<br>≤ 10 VDC|| |Release current at logic state 0<br>≤ 0.8 mA|| |Response time<br>1 to 2 cycle times|| |Sensor type<br>Contact or 3-wire PNP|| |Conforming to IEC/EN 61131-2<br>Type 1|| |Input type<br>Resistive|| |Isolation between power supply and inputs<br>None|| |Isolation between inputs<br>None|| |Protection against polarity inversions<br>Yes|| |Status indicator<br>No|On LCD screen| |Cable length<br>≤ 100 m|| |**Input used as high speed digital input**|| |Maximum counting frequency<br>3 channels encoder (I1, I2, I3): 5 kHz*<br>2 independent counters (I1, I2) (I3, I4) (Cumul, IND, DIR): 2 channels: 10 kHz*,<br>4 channels: 5 kHz*,<br>2 independent counters (I1, I2) (I3, I4) (PH, PH2): 2/4 channels: 5 kHz*<br>4 independent counters (I1, I2, I3, I4) (Up/Down) : 1 channel: 15 kHz*, 2 channels: 10 kHz*, > 2<br>channels: 5 kHz*<br>* with a time cycle ≤ 10 ms and a ton / toff = 50% ± 5%, level 0 < 2V and level 1 > 20,4V|| |Other functions<br>4 tachometers (I1, I2, I3, I4 )|| |Cable length<br>≤ 3 m with shielded twisted cable|| |**Digital 24 VDC and analog inputs 12 bits / 28.8 V - potentiometer - 8 inputs from I5 to IC**|| |**Input used as digital input**|| |Input voltage<br>24 VDC (-15% / +20%)|| |Input current<br>1.8 mA @ 20.4 V<br>2.1 mA @ 24 V<br>2.5 mA @ 28.8 V|| |Input impedance<br>11.6 kΩ|| |Logic 1 voltage threshold<br>≥ 11 VDC|| |Making current at logic state 1<br>≥ 1 mA|| |Logic 0 voltage threshold<br>≤ 9 VDC|| |Release current at logic state 0<br>≤ 0.7 mA|| |Response time<br>1 to 2 cycle times|| |Sensor type<br>Contact or 3-wire PNP|| |Conforming to IEC/EN 61131-2<br>Type 1|| |Input type<br>Resistive|| |Isolation between power supply and inputs<br>None|| |Isolation between inputs<br>None|| |Protection against polarity inversions<br>Yes|| **|** AUTOMATION.CROUZET.COM **| 4** **|** Logic Controller **|** 06/2018 **==> picture [495 x 642] intentionally omitted <==** **----- Start of picture text -----**<br> XBP24 XBP24-E XDP24 XDP24-E<br>Status indicator No On LCD screen<br>Cable length ≤ 30 m<br>Input used as analog input<br>Measuring range 0 → 10 V, 0 → V power supply or Voltmeter<br>Input impedance 11.6 kΩ<br>Maximum value without destruction 28.8 VDC max<br>Input type Common mode<br>Resolution 12 bit at maximum input voltage (10 bit at 10V)<br>Value of LSB 7.03 mV<br>Conversion time Controller cycle time<br>Maximum error in 0-10V mode ± 3.5 % of full scale at 25°C (77°F)<br>± 5 % of full scale at 55°C (131°F)<br>Maximum error in 0-V power supply mode ± 5 % of full scale at 25°C (77°F)<br>± 6.2 % of full scale at 55°C (131°F)<br>Repeat accuracy at 55°C (131°F) ± 2 %<br>Voltmeter From 0 to 30.5 V, 5%<br>Isolation between analogue channel and None<br>power supply<br>Protection against polarity inversions Yes<br>Potentiometer control 2.2 kΩ / 0.5 W (recommended), 10 KΩ max.<br>Cable length ≤ 10 m with shielded twisted cable (sensor not isolated)<br>Digital 24 VDC - 4 inputs from ID to IG<br>Input voltage 24 VDC (-15% / +20%)<br>Input current 1.5 mA @ 20.4 V<br>1.7 mA @ 24 V<br>2.1 mA @ 28.8 V<br>Input impedance 13.9 kΩ<br>Logic 1 voltage threshold ≥ 11 VDC<br>Making current at logic state 1 ≥ 0.8 mA<br>Logic 0 voltage threshold ≤ 8 VDC<br>Release current at logic state 0 ≤ 0.5 mA<br>Response time 1 to 2 cycle times<br>Sensor type Contact or 3-wire PNP<br>Conforming to IEC/EN 61131-2 Type 1<br>Input type Resistive<br>Isolation between power supply and inputs None<br>Isolation between inputs None<br>Protection against polarity inversions No<br>Status indicator No On LCD screen<br>Cable length ≤ 30 m<br>Outputs<br>6 A relay output - 2 outputs from O1 to O2<br>Breaking voltage 250 VAC max<br>Breaking current 6 A<br>Derating: UL: ≥ 45°C (113°F): 4A max<br>Maximum breaking current in the common IEC @ 25°C (77 °F): 12 A<br>IEC @ 60°C (140 °F) or UL: 10 A<br>Mechanical life 5 000 000 operations (cycles)<br>**----- End of picture text -----**<br> **|** AUTOMATION.CROUZET.COM **| 5** **|** Logic Controller **|** 06/2018 |**XBP24**<br>**XBP24-E**<br>**XDP24**<br>**XDP24-E**<br>Electrical durability for 50 000 operating<br>cycles<br>24 VDC tau = 0 ms: 6 A, tau = 7 ms: 3 A, tau = 15 ms: 1.8 A<br>Usage category DC-12: 24 V, 6 A<br>Usage category DC-14: 24 V, 1.8 A<br>250 VAC cos phi = 1: 6 A, cos phi = 0.7: 5 A, cos phi = 0.4: 2.5 A<br>Usage category AC-12: 250 V, 6 A<br>Usage category AC-13: 250 V, 5 A<br>Usage category AC-15: 250 V, 2 A|**XBP24**<br>**XBP24-E**<br>**XDP24**<br>**XDP24-E**<br>Electrical durability for 50 000 operating<br>cycles<br>24 VDC tau = 0 ms: 6 A, tau = 7 ms: 3 A, tau = 15 ms: 1.8 A<br>Usage category DC-12: 24 V, 6 A<br>Usage category DC-14: 24 V, 1.8 A<br>250 VAC cos phi = 1: 6 A, cos phi = 0.7: 5 A, cos phi = 0.4: 2.5 A<br>Usage category AC-12: 250 V, 6 A<br>Usage category AC-13: 250 V, 5 A<br>Usage category AC-15: 250 V, 2 A|**XBP24**<br>**XBP24-E**<br>**XDP24**<br>**XDP24-E**<br>Electrical durability for 50 000 operating<br>cycles<br>24 VDC tau = 0 ms: 6 A, tau = 7 ms: 3 A, tau = 15 ms: 1.8 A<br>Usage category DC-12: 24 V, 6 A<br>Usage category DC-14: 24 V, 1.8 A<br>250 VAC cos phi = 1: 6 A, cos phi = 0.7: 5 A, cos phi = 0.4: 2.5 A<br>Usage category AC-12: 250 V, 6 A<br>Usage category AC-13: 250 V, 5 A<br>Usage category AC-15: 250 V, 2 A|**XBP24**<br>**XBP24-E**<br>**XDP24**<br>**XDP24-E**<br>Electrical durability for 50 000 operating<br>cycles<br>24 VDC tau = 0 ms: 6 A, tau = 7 ms: 3 A, tau = 15 ms: 1.8 A<br>Usage category DC-12: 24 V, 6 A<br>Usage category DC-14: 24 V, 1.8 A<br>250 VAC cos phi = 1: 6 A, cos phi = 0.7: 5 A, cos phi = 0.4: 2.5 A<br>Usage category AC-12: 250 V, 6 A<br>Usage category AC-13: 250 V, 5 A<br>Usage category AC-15: 250 V, 2 A| |---|---|---|---| |Minimum switching capacity<br>100 mA (at minimum voltage of 12V)|||| |Maximum operating rate<br>Off load: 10 Hz<br>At operating current: 0.1 Hz|||| |Voltage for withstanding shocks<br>In accordance with IEC/EN 60947-1 and IEC/EN 60664-1: 4 kV|||| |Response time<br>Make = 1 cycle time + 8 ms typical<br>Release = 1 cycle time + 4 ms typical|||| |Built-in protections<br>Against short-circuits: None<br>Against over voltages and overload: None|||| |Status indicator<br>No||On LCD screen|| |Cable length<br>≤ 30 m|||| |**8 A relay output - 6 outputs from O3 to O8**|||| |Breaking voltage<br>250 VAC max|||| |Breaking current<br>8 A<br>Derating: CEI ≥ 55°C (131°F) or UL: ≥ 45°C (113°F): 6A max|||| |Maximum breaking current in the common<br>IEC @ 25°C (77°F): C3, C6: 8A ; C4, C5: 16 A<br>IEC @ 60°C (140 °F) or UL: C3, C6: 8 A ; C4, C5: 10 A|||| |Mechanical life<br>20 000 000 operations (cycles)|||| |Electrical durability for 50 000 operating<br>cycles<br>24 VDC tau = 0 ms: 8 A, tau = 7 ms: 3 A, tau = 15 ms: 1.5 A<br>Usage category DC-12: 24 V, 8 A<br>Usage category DC-14: 24 V, 1.5 A<br>250 VAC cos phi = 1: 8 A, cos phi = 0.7: 4.75 A, cos phi = 0.4: 3 A<br>Usage category AC-12: 250 V, 8 A<br>Usage category AC-13: 250 V, 4.3 A<br>Usage category AC-15: 250 V, 1.5 A|||| |Minimum switching capacity<br>100 mA (at minimum voltage of 12V)|||| |Maximum operating rate<br>Off load: 10 Hz<br>At operating current: 0.1 Hz|||| |Voltage for withstanding shocks<br>In accordance with IEC/EN 60947-1 and IEC/EN 60664-1: 4 kV|||| |Response time<br>Make = 1 cycle time + 10 ms typical<br>Release = 1 cycle time + 5 ms typical|||| |Built-in protections<br>Against short-circuits: None<br>Against over voltages and overload: None|||| |Status indicator<br>No||On LCD screen|| |Cable length<br>≤ 30 m|||| |**Ethernet network**|||| |Programming / exploitation<br>-|USB & Ethernet port /<br>Ethernet port|-|USB & Ethernet port /<br>Ethernet port| |Ethernet connection<br>-|Type RJ45, 10/100<br>Mbit/s, MDI/MDIX|-|Type RJ45, 10/100<br>Mbit/s, MDI/MDIX| |Adressage<br>-|Static or dynamic<br>(DHCP server / Auto<br>IP)|-|Static or dynamic<br>(DHCP server / Auto<br>IP)| |Protocols<br>-|Modbus TCP (client<br>/ server), Discovery,<br>UDP, TCP, SMTP, SSL<br>(workshop communi-<br>cation via Ethernet)|-|Modbus TCP (client<br>/ server), Discovery,<br>UDP, TCP, SMTP, SSL<br>(workshop communi-<br>cation via Ethernet)| |Cable length<br>-|Maximun length<br>between 2 devices:<br>100 m / 3937 inch|-|Maximun length<br>between 2 devices:<br>100 m / 3937 inch| **|** AUTOMATION.CROUZET.COM **| 6** **|** Logic Controller **|** 06/2018 **==> picture [485 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> XBP24 XBP24-E XDP24 XDP24-E<br>- -<br>Ethernet earthing Yes, refer to the quick Yes, refer to the quick<br>reference guide sup- reference guide sup-<br>plied with the product plied with the product<br>Technical sketches<br>Dimensions (mm)<br>Version XBP24 XBP24-E XDP24 XDP24-E<br>aac om H<br>1 ray U i<br>Connections<br>INPUTS<br>**----- End of picture text -----**<br> **|** AUTOMATION.CROUZET.COM **| 7** **|** EnteteProduct **|** 06/2018 ## **OUTPUTS** ## **Warning:** The product information contained in this catalogue is given purely as information and does not constitute a representation, warrantly or any form of contractual commitment. Crouzet Automatismes SAS and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsability of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.
Updated at April 26, 2026
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →