2866161
Analogue Timer, ETD, Multifunction, 50 ms, 100 h, 7 Ranges, 2 Changeover Relays
- Manufacturer: PHOENIX CONTACT
- Product type: Analogue Timers - DIN Rail
- Time Max: 100h
- Time Min: 50ms
- Timer Output: 2 Changeover Relays
- Product Range: ETD
- Timer Functions: Multifunction
- Supply Voltage Max: 240V
- No. of Timing Ranges: 7Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 101.44 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **ETD-SL-1T-DTF** ## **Multifunctional timer relay with one adjustable time** Data sheet 102571_en_06 © PHOENIX CONTACT - 2013-05-31 ## **1 Description** Increasingly higher demands are being placed on safety and system availability – across all sectors. Processes are becoming more and more complex, not only in mechanical engineering and the chemical industry, but also in plant and automation technology. Demands on power engineering are also increasing constantly. The timer relays in the ETD series can be used to control time sequences in production and process technology. ## **Features** - One adjustable time - - Time range of 50 ms to 100 hours (seven setting ranges) - Non-floating control input - Delay functions - - Wiper functions - Flashing function - Wide-range power supply unit - Two floating PDTs ## **WARNING: Risk of electric shock** Never carry out work when voltage is present. Oo Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. ~~Ee~~ **ETD-SL-1T-DTF** ## **2 Ordering data** |**Description**|**Type**|**Order No.**|**Pcs. / Pkt.**| |---|---|---|---| |Multifunctional timer relay with one adjustable time|ETD-SL-1T-DTF|2866161|1| ## **3 Technical data** |**Input data**|| |---|---| |Input voltage range|24 V DC ... 240 V DC -20 % ... +25 %| ||24 V AC ... 240 V AC -15 % ... +10 %| |Nominal frequency|48 Hz ... 63 Hz| |Temperature coefficient, typical|≤ 0.01 %/K| |Recovery time|500 ms| |Time setting range|50 ms ... 100 h (7 time end ranges)| |Function|E: With switch-on delay| ||R: With release delay and control contact| ||Es: With switch-on delay and control contact| ||Wu: With single shot leading edge, voltage controlled| ||Ws: With single shot leading edge and control contact| ||Wa: With single shot trailing edge and control contact| ||Bi: Flashing beginning with pulse| ||Bp: Flashing beginning with pause| |Basic accuracy|± 1 % (of scale end value)| |Setting accuracy|≤ 5 % (of scale end value)| |Repeat accuracy|≤ 0.5 % ±5 ms| |Nominal power consumption|2.5 VA (1 W)| ||| |**Output data**|| |Contact type|2 floating PDT contacts| |Nominal insulation voltage|250 V AC (in acc. with IEC 60664-1)| |Interrupting rating (ohmic load) max.|750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing)| ||1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing)| |Output fuse|5 A (fast-blow)| ||| |**Control contact**|| |Control contact|Non-floating, terminals A1-B1| |Load capacity|Parallel switched minimum load current 1 VA (0.5 W), terminals A2-B1| |Control pulse length|min. 70 ms| ||| |**General data**|| |Mechanical service life|Approx. 2 x 107cycles| |Service life, electrical|Approx. 2 x 105cycles at ohmic load, 1000 VA| |Switching frequency|max. 60 (per minute at 100 VA ohmic load)| ||max. 6 (per minute at 1000 VA ohmic load)| |Operating mode|100% operating factor| |Degree of protection|IP40 (housing) / IP20 (connection terminal blocks)| |Pollution degree|2 (according to EN 50178)| |Surge voltage category|III, basic insulation (as per EN 50178)| |Rated insulation voltage|300 V (According to EN 50178)| |Inflammability class according to UL 94|V0| |Mounting|on standard DIN rail NS 35 in accordance with EN 60715| |Mounting position|Any| |Width|22.5 mm| PHOENIX CONTACT **2** **102571_en_06** **ETD-SL-1T-DTF** |**General data [...]**|| |---|---| |Height|90 mm| |Depth|113 mm| |Type of housing|Polyamide PA, self-extinguishing| |Color|green| |Weight|160 g| ||| |**Connection data**|| |Conductor cross section, solid|0.5 mm² ... 2.5 mm²| |Conductor cross section, stranded|0.5 mm² ... 2.5 mm²| |Stripping length|8 mm| |Connection method|Screw connection| |Tightening torque|1 Nm| ||| |**Ambient conditions**|| |Ambient temperature (operation)|-25 °C ... 55 °C| ||-25 °C ... 40 °C (corresponds to UL 508)| |Ambient temperature (storage/transport)|-25 °C ... 70 °C| |Permissible humidity (operation)|15 % ... 85 %| |Climatic class|3K3 (in acc. with EN 60721)| ||| |**Conformance / approvals**|| |Conformance|CE-compliant| |UL, USA / Canada|UL/C-UL listed UL 508| ||| |**Conformance with EMC Directive 2004/108/EC**|| |Noise immunity according to|EN 61000-6-2| |Noise emission according to|EN 61000-6-4| |**Conformance with LV directive 2006/95/EC**|| |---|---| |Industrial timer relays according to|EN 61812-1/A11| ## **4 DC breaking capacity** **==> picture [238 x 186] intentionally omitted <==** **----- Start of picture text -----**<br> 20<br>10<br>5 1<br>2<br>1 2<br>0,5<br>0,2<br>0,1<br>10 20 30 50 70 100 200 300 400500<br>Switching voltage [V]<br>1 DC, ohmic load, 2 contacts in series<br>2 DC, ohmic load, 1 contact<br>Switching current [A]<br>**----- End of picture text -----**<br> PHOENIX CONTACT **3** **102571_en_06** **ETD-SL-1T-DTF** ## **5 Block diagram** **==> picture [238 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> B1 16 18 26 28<br>A1<br>t<br>A2<br>15 25<br>U = 24...240 V AC/DC<br>**----- End of picture text -----**<br> ## **6 Safety notes** ## **WARNING: Risk of electric shock** Never carry out work when voltage is present. ## **7 Structure** **==> picture [238 x 222] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>6<br>2<br>5<br>4<br>3<br>B1<br>25<br>26<br>28<br>A1<br>15<br>16<br>18<br>A2<br>Wa<br>.05.2 .4 .6 .8<br>s 101m1 10 1100101h<br>EsREWu EWaBpBi<br>TIME<br>FUNCTION<br>Timer<br>U / t<br>REL<br>DTF1T-<br>SL-<br>D-TE<br>**----- End of picture text -----**<br> - **1** "U/t" LED: Supply and adjustable time TIME - **2** "REL" LED: Output relay - **3** "FUNCTION" rotary switch: Function selection - **4** Rotary switch "TIME": Time end range - **5** "TIME" potentiometer: Preset value - **6** Universal snap-on foot for EN DIN rails PHOENIX CONTACT **4** **102571_en_06** **ETD-SL-1T-DTF** ## **8 Installation** ## **WARNING: Risk of electric shock** Never carry out work when voltage is present. The module can be snapped onto all 35 mm DIN rails according to EN 60715. An integrated wide-range power supply unit enables the connection of a supply voltage in the range from 24 V AC/DC to 240 V AC/DC. ## **9 Time setting** **==> picture [119 x 222] intentionally omitted <==** **----- Start of picture text -----**<br> 2<br>1<br>A1 B1 15<br>25 26 28<br>16 18 A2<br>.4 .6<br>.2 .8<br>.05 1<br>m1 10 1 h<br>s 10 10<br>1 100<br>Wu EWa<br>Es<br>R Bi<br>E Bp<br>TIME<br>FUNCTION<br>Wa<br>U / t Timer<br>REL<br>DTF1T-<br>L-<br>S<br>D-<br>T<br>E<br>**----- End of picture text -----**<br> ## **Example:** - 1 Specification of the time end range using a rotary switch, e.g. 10 m (10 minutes) - **2** Fine setting of the time using a potentiometer, e.g. 0.4 **Set time:** 0.4 x 10 minutes = 4 minutes ## **10 Diagnostics** The LEDs indicate the following error states: ## **"U/t" LED (Green)** - LED flashes: Voltage present, set time running - LED ON: Voltage present, set time has elapsed ## **"REL" LED (Yellow)** - LED ON: Output relay has picked up - LED OFF: Output relay has dropped out **5** PHOENIX CONTACT **102571_en_06** **ETD-SL-1T-DTF** ## **11 Connection examples** ## **NOTE:** When the control input is connected to a parallel load, ensure that the minimum load connected in parallel is > 1 VA. **==> picture [238 x 222] intentionally omitted <==** **----- Start of picture text -----**<br> A1 B1 15<br>15 25<br>16 18 26 28<br>25 26 28<br>16 18 A2<br>**----- End of picture text -----**<br> Connection without control contact **==> picture [238 x 222] intentionally omitted <==** **----- Start of picture text -----**<br> S<br>A1 B1 15<br>15 25<br>16 18 26 28<br>25 26 28<br>16 18 A2<br>**----- End of picture text -----**<br> Connection with control contact **==> picture [238 x 222] intentionally omitted <==** **----- Start of picture text -----**<br> S<br>A1 B1 15<br>15 25<br>16 18 26 28<br>25 26 28<br>16 18 A2<br>**----- End of picture text -----**<br> Connection with control contact and parallel load (e.g., relay) **6** PHOENIX CONTACT **102571_en_06** **ETD-SL-1T-DTF** ## **12 Function** ## **NOTE: Module can become damaged** Only set the functions when the module is switched off. **==> picture [238 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>LED REL, R<br>t t t t t<br>**----- End of picture text -----**<br> **==> picture [238 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>LED REL, R<br>t t t t t<br>**----- End of picture text -----**<br> **==> picture [238 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>LED REL, R<br>t < t<br>**----- End of picture text -----**<br> ## **Bi: Flashing Beginning With Pulse** When supply voltage U is applied, the output relay picks up (yellow "REL" LED is ON) and set time t starts running (green "U/t" LED flashes). Once time t has elapsed, the output relay drops out (yellow "REL" LED is OFF) and set time t starts running again. The output relay is controlled at a ratio of 1:1, until the supply voltage is interrupted. For the flashing function the pulse and pause times are the same, as it is only possible to set one time. ## **Bp: Flashing Beginning With Pause** When supply voltage U is applied, set time t starts running (green "U/t" LED flashes). Once time t has elapsed, the output relay picks up (yellow "REL" LED is ON) and set time t starts running again. Once time t has elapsed, the output relay drops out (yellow "REL" LED is OFF). The output relay is controlled at a ratio of 1:1, until the supply voltage is interrupted. For the flashing function the pulse and pause times are the same, as it is only possible to set one time. ## **E: With Switch-On Delay** When supply voltage U is applied, set time t starts running (green "U/t" LED flashes). Once time t has elapsed (green "U/ t" LED is ON), the output relay picks up (yellow "REL" LED is ON). This state is maintained until supply voltage U is interrupted. If supply voltage U is interrupted before time t has elapsed, the elapsed time is deleted (relay does not pick up). The next time supply voltage U is applied, the time is restarted. PHOENIX CONTACT **7** **102571_en_06** **ETD-SL-1T-DTF** **==> picture [238 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>A1 - B1<br>LED REL, R<br>t < t<br>**----- End of picture text -----**<br> **==> picture [238 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>A1 - B1<br>LED REL, R<br>t < t<br>**----- End of picture text -----**<br> **==> picture [238 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>LED REL, R<br>t < t<br>**----- End of picture text -----**<br> **==> picture [238 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>A1 - B1<br>LED REL, R<br>t t<br>**----- End of picture text -----**<br> ## **Es: With Switch-On Delay and Control Contact** Supply voltage U must be applied permanently at the device (green "U/t" LED is ON). When control contact A1-B1 is closed, set time t starts running (green "U/t" LED flashes). Once time t has elapsed (green "U/t" LED is ON), the output relay picks up (yellow "REL" LED is ON). This state is maintained until the control contact is opened. If the control contact is opened before time t has elapsed, the elapsed time is deleted (relay does not pick up) and restarted with the next cycle. ## **R: With Release Delay and Control Contact** Supply voltage U must be applied permanently at the device (green "U/t" LED is ON). When control contact A1-B1 is closed, the output relay picks up (yellow "REL" LED is ON). If control contact A1-B1 is opened, set time t starts running (green "U/t" LED flashes). Once time t has elapsed (green "U/ t" LED is ON), the output relay drops out (yellow "REL" LED is OFF). If the control contact is closed again before time t has elapsed, the elapsed time is deleted and restarted with the next cycle. ## **Wu: With single shot leading edge, voltage controlled** When supply voltage U is applied, the output relay picks up (yellow "REL" LED is ON) and set time t starts running (green "U/t" LED flashes). Once time t has elapsed (green "U/t" LED is ON), the output relay drops out (yellow "REL" LED is OFF). This state is maintained until supply voltage U is interrupted. If the supply voltage is interrupted before time t has elapsed, the output relay drops out. The elapsed time is deleted and restarted the next time the supply voltage is applied again. ## **Ws: With single shot leading edge and control contact** Supply voltage U must be applied permanently at the device (green "U/t" LED is ON). When control contact A1-B1 is closed, the output relay picks up (yellow "REL" LED is ON) and set time t starts running (green "U/t" LED flashes). Once time t has elapsed (green "U/t" LED is ON), the output relay drops out (yellow "REL" LED is OFF). The control contact can be freely switched during this time. Another cycle cannot be started until the current cycle has been completed. PHOENIX CONTACT **8** **102571_en_06** **ETD-SL-1T-DTF** **==> picture [238 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>A1 - B1<br>LED REL, R<br>t t<br>**----- End of picture text -----**<br> ## **Wa: With single shot trailing edge and control contact** Supply voltage U must be applied permanently at the device (green "U/t" LED is ON). Control contact A1-B1 closing has no influence on the position of the output relay. When control contact A1-B1 is opened, the output relay picks up (yellow "REL" LED is ON) and set time t starts running (green "U/t" LED flashes). Once time t has elapsed (green "U/t" LED is ON), the output relay drops out (yellow "REL" LED is OFF). The control contact can be freely switched during this time. Another cycle cannot be started until the current cycle has been completed. **9** **PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com** **102571_en_06**
Updated at February 9, 2023
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →