2702976
SAFETY SWITCH SENSOR, 140MM, 40MA, CABLE
- Manufacturer: PHOENIX CONTACT
- Product type: Reed Proximity Sensors
- SVHC: Lead titanium zirconium oxide (04-Feb-2026)
- Product Range: PSR CT Series
- Supply Current: 40mA
- Sensor Mounting: Cable
- Sensing Range Max: 140mm
- Sensing Distance Max: 140mm
- Operating Temperature Max: 55°C
- Operating Temperature Min: -25°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 122.71 € |
| Current stock | 10+ |
| Lead time | 30 days |
https://www.phoenixcontact.com/gb/products/2702976 ## Safety switch sensor - PSR-CT-F-SEN-1-8 - 2702976 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Proximity safety circuit up to Cat. 4, PL e (EN ISO 13849), SIL 3 (IEC 61508), fixcode sensor with RFID coding, model 4 (EN ISO 14119), automatic or manual start, integrated diagnostics, 24 V DC supply, IP69K, M12 connector The figure shows a product version of the article ## Product Description The PSR-CT safety circuit consists of a combination of a PSR-CT-...-SEN-1-8 sensor with varying coding types and a coded PSR-CT-C-ACT actuator. It provides maximum tamper protection and the highest level of safety in accordance with EN ISO 14119. The PSR-CT safety circuit is available with the following types of coding: Fixcode: For the sensor to detect the actuator, the actuator must first be associated with the sensor via a learning process. The learning process can only be completed once. The sensor and actuator are then permanently assigned to each other by their coding. Safety circuits with fixcode evaluation achieve a high coding level. Unicode: For the sensor to detect the actuator, the actuator must first be assigned to the sensor via a learning process. The learning process for a new actuator can be repeated any number of times. The sensor only detects the last learned actuator. Safety circuits with unicode evaluation achieve a high coding level. Multicode: The sensor detects every actuator of the approved type. No specific actuator code can be assigned. Safety circuits with multicode evaluation achieve a low coding level. ## Your advantages Integrated reset function on the switch - 4 actuation settings, 3 travel directions - Tamper protection via RFID transponder technology - Rapid diagnostics, thanks to comprehensive status information - Consistent M12 connection technology for convenient installation - Safe series connection in accordance with EN ISO 14119 - Flexible use, thanks to compact design - Safe, cost-effective complete solution Key Commercial Data Packing unit 1 pc ~~a GO~~ GTIN ~~po~~ GTIN 4055626447032 ~~a _ (4°055626°447032~~ Weight per Piece (excluding packing) 41.300 g ~~GO~~ 02/27/2020 Page 1 / 9 https://www.phoenixcontact.com/gb/products/2702976 ## Safety switch sensor - PSR-CT-F-SEN-1-8 - 2702976 |Custom tariff number<br>85365019<br>Country of origin<br>Germany<br>~~<<~~| |---| |Technical data| |Dimensions| |Width<br>26.5 mm<br>Height<br>40 mm<br>Depth<br>18 mm<br>~~——~~| |Ambient conditions| |Ambient temperature (operation)<br>-25 °C ... 55 °C<br>Ambient temperature (storage/transport)<br>-40 °C ... 70 °C<br>~~——————~~| |Power supply| |Supply voltage|24 V DC ±15 % (PELV, controlled, residual ripple < 5% )| |---|---| |Current consumption|max. 40 mA| |Protection|min. 0.25 A (to be performed externally)| ||max. 8 A (to be performed externally)| ## Alarm outputs |Designation|DGN| |---|---| |Output description|p-wired| |Number of outputs|1| |Short-circuit-proof|yes| |Output voltage|min. (UB- 1.5 V (HIGH))| ||max. (UB(HIGH))| ||min. 0 V DC (LOW)| ||max. 1 V DC (LOW)| |Current IDGN|min. 1 mA| |Safety outputs|| |Designation|FO1A, FO1B| |Output description|Semiconductor outputs, p-wired| |Number of outputs|2| |Output voltage|min. (UB- 1.5 V (HIGH FO1A, FO1B))| ||max. (UB(HIGH FO1A, FO1B))| ||min. 0 V DC (LOW FO1A/FO1B)| ||max. 1 V DC (LOW FO1A/FO1B)| |Switching current|min. 1 mA (per safety output)| ||max. 150 mA (per safety output)| |Short-circuit-proof|yes| |Utilization category in accordance with IEC 60947-5-2|150 mA (24 V (DC13))| |Note on protection circuit|NOTE: Protect the outputs under inductive loads with a freewheeling<br>diode.| |Residual current|≤ 0.25 mA| 02/27/2020 Page 2 / 9 https://www.phoenixcontact.com/gb/products/2702976 ## Safety switch sensor - PSR-CT-F-SEN-1-8 - 2702976 ## Technical data ## Times |Switch-on delay|typ. 5 s (after switching UBon)| |---|---| |Risk time according to EN 60947-5-3|max. 125 ms (Stand-alone device)| |Delay time|typ. 10 ms (Risk time delay per device)| |Switch-on time|max. 400 ms (for the safety outputs)| |Discrepancy time|max. 10 ms (between the safety outputs)| |Test pulses|typ. 300 µs (Test pulse duration)| ||approx. 100 ms (Test pulse interval)| |General|| |Net weight<br>41.3 g<br>Mounting position<br>any<br>Mounting type<br>not flush<br>Minimum distance<br>140 mm (between two safety circuits)<br>7 mm (between sensor and actuator when traveling in the Y-direction)<br>Assembly instructions<br>Note EN ISO 14119<br>Maximum tightening torque to secure: 0.8 Nm<br>Degree of protection<br>IP65/IP67/IP69/IP69K<br>IP67 (with SAC cabling)<br>Protection class<br>III<br>Short-circuit current<br>typ. 100 A (conditional short-circuit current)<br>Switching frequency<br>max. 1 Hz<br>Housing material<br>PBT<br>Housing color<br>yellow<br>Status display<br>2 LEDs<br>~~=~~|| |Connection data|| |Connection method<br>Connector<br>Connection technology<br>M12 connector<br>pluggable<br>no<br>Number of positions<br>8<br>~~_—S————~~|| |Safety-related characteristic data|| |Designation<br>IEC 61508 - High demand<br>Safety Integrity Level (SIL)<br>3<br>Designation<br>EN ISO 13849<br>Performance level (PL)<br>e<br>Category<br>4<br>~~SSS~~|| |Standards and Regulations|| |Rated insulation voltage<br>max. 300 V<br>Rated surge voltage<br>max. 1.5 kV<br>Degree of pollution<br>3<br>Vibration (operation)<br>in accordance with EN 60947-5-2<br>~~_—S———~~|| ||02/27/2020 Page 3 / 9| https://www.phoenixcontact.com/gb/products/2702976 ## Safety switch sensor - PSR-CT-F-SEN-1-8 - 2702976 ## Technical data Standards and Regulations EMC conformance EN 60947-5-3 ~~CL~~ Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 10; For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” ## Drawings Application drawing 02/27/2020 Page 4 / 9 https://www.phoenixcontact.com/gb/products/2702976 ## Safety switch sensor - PSR-CT-F-SEN-1-8 - 2702976 Application drawing Application drawing 02/27/2020 Page 5 / 9 https://www.phoenixcontact.com/gb/products/2702976 ## Safety switch sensor - PSR-CT-F-SEN-1-8 - 2702976 Dimensional drawing 02/27/2020 Page 6 / 9 https://www.phoenixcontact.com/gb/products/2702976 ## Safety switch sensor - PSR-CT-F-SEN-1-8 - 2702976 ## Application drawing ## Classifications ## eCl@ss |eCl@ss 5.0|eCl@ss 5.0|27272400| |---|---|---| |eCl@ss 6.0|eCl@ss 6.0|27272400| |eCl@ss 7.0|eCl@ss 7.0|27272403| |eCl@ss 9.0|eCl@ss 9.0|27272403| ## ETIM |ETIM 5.0|ETIM 5.0|EC001526| |---|---|---| |ETIM 6.0|ETIM 6.0|EC001526| |ETIM 7.0|ETIM 7.0|EC001526| ## Approvals ## Approvals ## Approvals UL Listed / cUL Listed / Functional Safety / FCC / Industry Canada / cULus Listed 02/27/2020 Page 7 / 9 https://www.phoenixcontact.com/gb/products/2702976 ## Safety switch sensor - PSR-CT-F-SEN-1-8 - 2702976 ## Approvals Ex Approvals ## Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 196162 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 196162 ~~DT~~ Functional Safety http://www.tuev-sued.de Z10 18 04 29429 005 ~~DT~~ FCC YG3-PSR1 ~~DT~~ Industry Canada 4720B-PSR1 cULus Listed ~~ee~~ Accessories Accessories Safety switches Safety switch actuator - PSR-CT-C-ACT - 2702973 Proximity safety circuit up to Cat. 4, PL e (EN ISO 13849), SIL 3 (IEC 61508), coded actuator, compatible with all sensor coding types, supplied inductively via the sensor, IP69K ## Terminal resistor Short-circuit connector - SAC-5P-M12MS BK BR 1-2-4 - 1054366 Termination plug for PSR-CT series RFID transponder switches, M12 male, 5-pos., closes the circuit at the last Y distributor in a series connection 02/27/2020 Page 8 / 9 https://www.phoenixcontact.com/gb/products/2702976 ## Safety switch sensor - PSR-CT-F-SEN-1-8 - 2702976 ## Accessories ## Y-distributor Y distributor - SAC-8PY-M/2XF BK 1-PSR - 1054338 Y distributor for PSR-CT series RFID transponder switches, M12 male/female, 5- and 8-pos., for safe series connection of up to 30 devices ## Y distributor - SAC-8PY-M/2XF BK 2-PSR - 1054339 Y distributor for PSR-CT series RFID transponder switches, M12 male/female, 5- and 8-pos., for implementation of a manual start circuit in the field ## Y distributor - SAC-8PY-M/2XF BK 3-PSR - 1054341 Y distributor for PSR-CT series RFID transponder switches, M12 male/female, 5- and 8-pos., for signal contact feedback to the PLC Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 02/27/2020 Page 9 / 9
Updated at April 17, 2026
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →