2700524
Safety Relay, 24 VDC, 3PST-NO, SPST-NC, PSRcompact Series, DIN Rail, 6 A, Screw
- Manufacturer: PHOENIX CONTACT
- Product type: Safety Relays
- SVHC: Lead (04-Feb-2026)
- IP Rating: IP20, IP54
- Coil Voltage: 24VDC
- Product Range: PSRcompact Series
- Relay Mounting: DIN Rail
- Contact Current: 6A
- Relay Terminals: Screw
- Contact Material: Silver Tin Oxide
- Contact Configuration: 3PST-NO, SPST-NC
- Contact Voltage AC Nom: 250V
- Contact Voltage DC Nom: 250V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 327.52 € |
| Current stock | 10+ |
| Lead time | 30 days |
https://www.phoenixcontact.com/gb/products/2700524 ## Safety relays - PSR-MC32-3NO-1NC-24-230UC-SC - 2700524 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Safety relay for emergency stop, safety doors, and light grids up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic or manual, monitored start, 3 enabling current paths, 1 signaling current path, US = 24 ... 230 V AC/DC, plug-in screw terminal block ## Your advantages Up to Cat.4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061 One or two-channel activation - 3 enabling current paths, 1 signaling current path - Manually monitored and automatic activation in a single device Cross-circuit detection ## Key Commercial Data Packing unit 1 pc ~~a Ge~~ GTIN 4l046356"912693 ~~Pe |URIONN IA~~ GTIN 4046356912693 ~~**a** Ge~~ Weight per Piece (excluding packing) 243.800 g ~~a~~ Custom tariff number ~~Q~~ 85371098 Country of origin Germany ~~a GO~~ ## Technical data ## Note EMC: class A product, see manufacturer's declaration in the download Utilization restriction area ## Dimensions |Width|22.5 mm| |---|---| |Height|112.2 mm| |Depth|114.5 mm| Ambient conditions 12/30/2019 Page 1 / 9 https://www.phoenixcontact.com/gb/products/2700524 ## Safety relays - PSR-MC32-3NO-1NC-24-230UC-SC - 2700524 ## Technical data ## Ambient conditions |Ambient conditions|| |---|---| |Ambient temperature (operation)|-40 °C ... 55 °C (observe derating)| |Ambient temperature (storage/transport)|-40 °C ... 85 °C| |Max. permissible relative humidity (operation)|75 % (on average, 85% infrequently, non-condensing)| |Max. permissible humidity (storage/transport)|75 % (on average, 85% infrequently, non-condensing)| |Maximum altitude|≤ 2000 m (Above sea level)| |Power supply|| |Designation|A1/A2| |Rated control circuit supply voltage US|24 V AC/DC ... 230 V AC/DC -15 % / +10 %| |Rated control supply current IS|typ. 103 mA (24 V DC)| ||typ. 47 mA (48 V DC)| ||typ. 38 mA (110 V AC)| ||typ. 21 mA (230 V AC)| |Power consumption at US|2.7 W (with DC)| ||2.9 W (with AC)| |Apparent power|typ. 5 VA (at US)| |Inrush current|< 80 A (Δt = 50 µs at Us)| |Filter time|2 ms (at A1 in the event of voltage dips at Us)| |Protective circuit|US: surge protection 275 V varistor / 411 V suppressor diode| |Digital inputs|| |12/30/2019 Page 2 / 9<br>Input name<br>Sensor circuit<br>S10, S11, S12, S13, S21, S22<br>Description of the input<br>safety-related sensor inputs<br>Input voltage range "0" signal<br>0 V DC ... 5 V DC (for safe Off; at S10/S12/S13)<br>Input current range "0" signal<br>0 mA ... 2 mA (for safe Off; at S10/S12/S13)<br>Inrush current<br>< 5 mA (with Us/Ixat S10/S12/S13)<br>> -5 mA (with Us/Ixto S22)<br>Current consumption<br>< 5 mA (with Us/Ixat S10/S12/S13)<br>> -5 mA (with Us/Ixto S22)<br>Filter time<br>max. 1.5 ms (to S10-S12; test pulse width; at 24 V DC)<br>7.5 ms (to S10-S12; test pulse rate; at 24 V DC)<br>Test pulse rate = 5 x Test pulse width<br>Max. permissible overall conductor resistance<br>150 Ω<br>Concurrence input 1/2<br>∞<br>Type of protection<br>Inputs: protection against polarity reversal, surge protection<br>Protective circuit/component<br>38.6 V suppressor diode<br>Input name<br>Start circuit<br>S34, S35<br>Description of the input<br>non-safety-related<br>NPN~~_=~~|| https://www.phoenixcontact.com/gb/products/2700524 ## Safety relays - PSR-MC32-3NO-1NC-24-230UC-SC - 2700524 ## Technical data ## Digital inputs |Number of inputs|2| |---|---| |Inrush current|< 10 mA (Δt = 330 ms)| |Current consumption|typ. 2.5 mA (S34)| ||typ. 1 mA (S35)| |Max. permissible overall conductor resistance|150 Ω| |Protective circuit/component|Suppressor diode| ## Relay outputs: enabling current path |Output name|Enabling current paths| |---|---| ||13/14, 23/24, 33/34| |Output description|safety-related N/O contacts| |Number of outputs|3 (undelayed)| |Contact type|3 enabling current paths| |Contact material|AgSnO2| |Switching voltage|min. 5 V AC/DC| ||max. 250 V AC/DC (Observe the load curve)| |Limiting continuous current|6 A (observe derating)| |Inrush current|min. 10 mA| ||max. 6 A| |Sq. Total current|72 A<br>2(observe derating)| |Switching capacity|min. 50 mW| |Switching frequency|max. 1 Hz| |Interrupting rating (ohmic load) max.|1500 VA (250 V AC, τ = 0 ms)| ||For additional values, see load curve| |Maximum interrupting rating (inductive load)|48 W (24 V DC, τ = 40 ms)| ||40 W (48 V DC, τ = 40 ms)| ||36 W (60 V DC, τ = 40 ms)| ||35 W (110 V DC, τ = 40 ms)| ||33 W (220 V DC, τ = 40 ms)| ||1500 VA (250 V AC, τ = 40 ms)| |Mechanical service life|10x 10<br>6cycles| |Switching capacity according to IEC 60947-5-1|5 A (24 V (DC13))| ||5 A (250 V (AC15))| |Output fuse<br>~~SS~~|6 A gL/gG<br>~~SS~~| ||4 A gL/gG (for low-demand applications)| Relay outputs: return current/signaling current path |Output name|Signaling current path| |---|---| |Output description|non-safety-related N/C contact| |Number of outputs|1 (undelayed)| |Contact type|1 signaling current path| 12/30/2019 Page 3 / 9 https://www.phoenixcontact.com/gb/products/2700524 ## Safety relays - PSR-MC32-3NO-1NC-24-230UC-SC - 2700524 ## Technical data Relay outputs: return current/signaling current path Contact material AgSnO2 Switching voltage min. 5 V AC/DC max. 250 V AC/DC Limiting continuous current 6 A Inrush current min. 10 mA max. 6 A Switching capacity min. 50 mW Switching frequency 1 Hz Mechanical service life 10x 106 cycles Output fuse 6 A gL/gG 4 A gL/gG (for low-demand applications) ~~==~~ Times Typical pickup time at US < 200 ms (when controlled via A1) Typical response time at US < 150 ms (automatic start) < 100 ms (manual, monitored start) Typical release time at US < 20 ms (when actuation is via the sensor circuit) Restart time < 1 s Recovery time < 500 ms ~~=~~ General Electromechanical relay with forcibly guided contacts in accordance with Relay type EN 50205 Nominal operating mode 100% operating factor Net weight 243.8 g Mounting position vertical or horizontal Mounting type DIN rail mounting Assembly instructions See derating curve Degree of protection IP20 Min. degree of protection of inst. location IP54 Housing material PBT Housing color yellow Operating voltage display 1 x green LED Status display 3 x green LED ~~=~~ Connection data Connection method Screw connection pluggable Yes Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² ~~=~~ 12/30/2019 Page 4 / 9 https://www.phoenixcontact.com/gb/products/2700524 ## Safety relays - PSR-MC32-3NO-1NC-24-230UC-SC - 2700524 ## Technical data ## Connection data Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 7 mm Screw thread M3 Safety-related characteristic data Stop category 0 Designation IEC 61508 - High demand Safety Integrity Level (SIL) 3 Designation IEC 61508 - Low demand Safety Integrity Level (SIL) 3 Designation EN ISO 13849 Performance level (PL) e Category 4 Designation EN 62061 Safety Integrity Level Claim Limit (SIL CL) 3 ~~=——~~ Standards and Regulations Designation Air clearances and creepage distances between the power circuits Standards/regulations DIN EN 50178; EN 60947-5-1 Rated insulation voltage 250 V AC Basic insulation 4 kV between enabling current path (23/24) and Rated surge voltage/insulation enabling current path (33/34) and signaling current path (41/42) Basic insulation 4 kV between all current paths and housing Safe isolation, reinforced insulation 6 kV between all other circuits Degree of pollution 2 Overvoltage category III Shock 15g Vibration (operation) 10 Hz ... 150 Hz, 2g Conformance CE-compliant Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” ~~==~~ Drawings 12/30/2019 Page 5 / 9 https://www.phoenixcontact.com/gb/products/2700524 ## Safety relays - PSR-MC32-3NO-1NC-24-230UC-SC - 2700524 **==> picture [58 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Block diagram<br>**----- End of picture text -----**<br> 12/30/2019 Page 6 / 9 https://www.phoenixcontact.com/gb/products/2700524 ## Safety relays - PSR-MC32-3NO-1NC-24-230UC-SC - 2700524 Circuit diagram 12/30/2019 Page 7 / 9 https://www.phoenixcontact.com/gb/products/2700524 ## Safety relays - PSR-MC32-3NO-1NC-24-230UC-SC - 2700524 ## Classifications eCl@ss |eCl@ss 4.0<br>40020600<br>eCl@ss 4.1<br>40020600<br>eCl@ss 5.0<br>27371900<br>eCl@ss 5.1<br>27371900<br>eCl@ss 6.0<br>27371800<br>eCl@ss 7.0<br>27371819<br>eCl@ss 8.0<br>27371819<br>eCl@ss 9.0<br>27371819<br>~~==~~| |---| |ETIM<br>ETIM 3.0<br>EC001449<br>ETIM 4.0<br>EC001449<br>ETIM 5.0<br>EC001449<br>ETIM 6.0<br>EC001449<br>ETIM 7.0<br>EC001449<br>~~—S—~~| |UNSPSC<br>UNSPSC 13.2<br>39121501<br>UNSPSC 18.0<br>39122205<br>UNSPSC 19.0<br>39122205<br>UNSPSC 20.0<br>39122205<br>UNSPSC 21.0<br>39122205<br>~~=—s=>~~| |Approvals| |Approvals| ## Approvals UL Listed / cUL Listed / Functional Safety / cULus Listed Ex Approvals Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 140324 ~~oo~~ 12/30/2019 Page 8 / 9 https://www.phoenixcontact.com/gb/products/2700524 ## Safety relays - PSR-MC32-3NO-1NC-24-230UC-SC - 2700524 Approvals cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 140324 ~~ee~~ Functional Safety 44-205-15124310 ~~a~~ cULus Listed ~~———~~ Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com 12/30/2019 Page 9 / 9
Updated at April 29, 2026
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →