Image not available
Illustrative purposes only
2440000224
Battery Charger, Desktop, Lead Acid, 264 V, 24 VDC Output, 2.5A, IP67
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MASCOT
- Product type:
- SVHC: No SVHC (10-Jun-2022)
- Plug Type: Mains Plug Sold Separately
- Product Range: 2440 Series
- Charge Current: 2.5A
- Output Voltage: 24V
- Supply Voltage: 264VAC
- Battery Size Code: -
- Battery Charger Type: Desktop
- No. of Cells Charged: -
- Battery Technologies Supported: Lead Acid
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 96.23 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **2440 LA** Max. 4.0 A ## Charger for lead acid batteries - 3-step charge control with microprocessor - Low current start up of deeply discharged batteries (step 0) - Unaffected by fluctuations in mains voltage - Protected against reverse polarity and short circuit proof - IP67 version available (both housing styles) - Custom design on request: - timer, charge current, other **==> picture [42 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 2440 IP67<br>**----- End of picture text -----**<br> - Temp. comp. charge voltage w. external temp sensor available Approvals: - Home Healthcare EN 60601-1-11 - Medically certified Safety: EN 60601-1 ed. 3.1 EMC: EN 60601-1-2 ed. 4 - UL approved For updates: see www.mascot.no ## TECHNICAL SPECIFICATIONS 12V **==> picture [41 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> MEDICAL IP67<br>**----- End of picture text -----**<br> ## **GENERAL INPUT/OUTPUT** ## **SAFETY PROTECTION EMC** **Input voltage:** 90 - 264 VAC **Line frequency:** 47 - 63 Hz **Max output power:** 58W (24V: 74W) **Ripple:** < 100 mV p-p **Efficiency (at 100% load):** > 85% **Switch frequency approx.:** 40 kHz **Leakage current with mains disconnected:** <200uA (0,15Ah/month) ## **Temperature range** - **Operating:** -25 to +40 °C **• Storage:** -25 to +85 °C **Dimensions (L×W×H):** 135 × 80 × 44 mm **Weight:** 390 g (890 g IP67) **Protection** Against reversed polarity and short circuit proof. Safety timer: charging of lower voltage batt (e.g. 6V/12V) will be limited to 1,2A/0,6A and term. after 30 min. Class II (Class I on request) **Insulation class:** Class II (Class I on request) **Insulation voltage Primary-secondary:** 4000VAC / 5700 VDC **Electrical safety std:** EN/IEC 60335-2-29, EN/ IEC/ANSI 60601-1 (3.1 Ed) & EN/IEC 60601-1-11 **EMC standards:** EN 55014-1 and -2, EN/IEC 61000-6-3, EN/IEC 61000-6-1, EN/IEC 60601-1-2 **Input terminal:** 2-pin IEC60320/C8 (3-pin C14) or fixed cord on request **Output terminals:** Battery clips or DC conn **IP-grade:** 41 (IP67 on request) **Rec. battery capacity:** 20 - 200 Ah ## **Voltage versions – see next page** **TS140121** **Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no** ## **Charge control - Ladekontroll (LED indication)** **==> picture [518 x 603] intentionally omitted <==** **----- Start of picture text -----**<br> Step 0 Step 0<br>< 30 min > 30 min Step 1 Step 2 Step 3<br>Float charge<br>(Yellow) (Red=error) (Yellow) (Flash Yellow) (Green)<br>a ee<br>rr ee eee eee eee<br>4.0A ± 0.2A 7.35V ± 0.1V 6.85V ± 0.1V (until I charge > 4.0A) 4.0A<br>1.2A ± 0.2A<br>6V < 0.2A (batt volt > 5.25V) (until I charge <1.2A or >4hr) supply current up to max 4.0A Pulsing current at safe float<br>(batt volt< 5.25V)<br>(until Vbat = 7.35V) tapering charge current for possible parallel load volt. level for max topp. of batt.<br>ee 4A ±0.2A eeee 14.7V ± 0.1V 13.7V ± 0.2V (until I charge > 4.0A) 4.0A<br>1.2A +- 0.2A<br>12V < 0.2A (batt volt >10.5V) (until I charge <1.2A or >4hr) supply current up to max. 4.0A Pulsing current at safe float<br>(batt volt< 10.5V)<br>(til Vbat = 14.7V) tapering charge current for possible parallel load volt. level for max topp. of batt.<br>ee ee 2.5A ± 0.2A ee ee 29.4V ± 0.1V 27.4V ± 0.2V (until I charge > 2.5A) ee ee 2.5A<br>0.6A ± 0.2A<br>24V < 0.2A (batt volt< 21V) (until I charge <0.6A or >4hr) supply current up to max 2.5A Pulsing current at safe float<br>(batt volt< 21V)<br>(until Vbat = 29.4V) tapering charge current for possible parallel load volt. level for max topp. of batt.<br>ee 0.4A ± 0.1A ee 1.6A ± 0.1A ee ee 44.1V ± 0.2V 41.1V ± 0.2V (until I charge > 1.6A) ee ee 1.6A<br>36V < 0.2A (batt volt > 31.5V) (until I charge <0.4A or >4hr) supply current up to max 1.6A Pulsing current at safe float<br>(batt volt< 31.5V)<br>(until Vbat = 44.1V) tapering charge current for possible parallel load volt. level for max topp. of batt.<br>[| 0.3A ± 0.1A of |ff 1.3A ± 0.1A 58.8V ± 0.3V 54.8V ± 0.3V (until I charge > 1.2A) 1.2A<br>48V < 0.2A (batt volt > 42V) (until I charge <0.3A or >4hr) supply current up to max 1.2A Pulsing current at safe float<br>(batt volt< 42V)<br>(until Vbat = 58.8V) tapering charge current for possible parallel load volt. level for max topp. of batt.<br>ee ee ee ee ee ee<br>INDICATOR:<br>INDICATOR: YELLOW INDICATOR: GREEN<br>FLASHING YELLOW<br>TTT<br>Charge Voltage<br>Charge Voltage<br>Battery Voltage<br>Current pulses at safe float voltage level<br>for maximum topping of battery capacity.<br>Pulse frequency: Microprocessor controlled.<br>Charge Current Pulse Current: max current<br>Start Current<br>Cut-Off Current<br>Low Current Start-Up at Vbatt <10.5V<br>Error Mode if <10.5V after 30 minutes<br>(for 12V system)<br>(0.5 hours)Start TimerStep 0 Boost ChargeStep 1 Top Up Charge (4 hours)Step 2 Float ChargeStep 3<br>TTT<br>Safety Timer (72 hours)<br>a——————<br>**----- End of picture text -----**<br> Charging characteristics and LED indication (LED) indikasjon (data for 12V version) **TS140121** **Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no** **2440** **==> picture [152 x 51] intentionally omitted <==** **==> picture [403 x 299] intentionally omitted <==** **----- Start of picture text -----**<br> 44 mm<br>135 mm<br>80 mm<br>**----- End of picture text -----**<br> **==> picture [422 x 261] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting brackets<br>TYPE 201970<br>1 mounting bracket per unit<br>Available separately<br>14mm<br>45 mm<br>41mm<br>49 mm<br>17 mm<br>Ø 12 mm<br>Ø 4 mm 72 mm<br>82 mm<br>**----- End of picture text -----**<br> **TS140121** **Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no** **2440 IP67** **==> picture [206 x 92] intentionally omitted <==** **==> picture [488 x 399] intentionally omitted <==** **----- Start of picture text -----**<br> Ø 5 mm Ø 5 mm<br>Ø 5 mm<br>135 mm<br>80 mm<br>12 mm<br>5 mm 5 mm<br>30 mm 30 mm<br>83 mm<br>93 mm<br>48 mm<br>5 mm<br>11 mm<br>70 mm<br>30 mm<br>140 mm<br>**----- End of picture text -----**<br> **TS140121** **Mascot AS Headquarters • PO Box 177 • 1601 Fredrikstad NORWAY • +47 69 36 43 00 • sales@mascot.no • www.mascot.no**
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →