2320416
Rechargeable Battery, 24 V, Lead Acid, 13 Ah, 1
- Manufacturer: PHOENIX CONTACT
- Product type: Batteries - Rechargeable
- SVHC: Lead (04-Feb-2026)
- Weight: 10.8kg
- Pack Quantity: 1
- Product Range: UPS BAT/VRLA-WTR Series
- External Depth: 178mm
- External Width: 172mm
- Battery Voltage: 24V
- External Height: 177mm
- Battery Capacity: 13Ah
- Battery IEC Code: -
- Battery NEDA Code: -
- Battery Size Code: -
- Battery Terminals: -
- Battery Compliance: -
- Battery Technology: Lead Acid
- Battery Type / Size: Lead-Acid
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 960.48 € |
| Current stock | 10+ |
| Lead time | 30 days |
## UPS-BAT/VRLA-WTR/24DC/13AH - Battery module 2320416 https://www.phoenixcontact.com/in/products/2320416 Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Battery module, lead AGM, VRLA technology, 24 V DC, 13 Ah, tool-free battery replacement, automatic detection, and communication with QUINT UPS-IQ ## Product description For continuous monitoring and intelligent management, there is constant communication with the QUINT UPS. Thanks to automatic detection of the battery module and tool-free switching during operation, quick installation is possible. The battery modules for QUINT UPS with IQ Technology leave the warehouse fully charged. ## Your advantages - Maximum buffer times at extreme temperatures - Pure lead AGM technology (Absorbent Glass Mat) ## Commercial data |Item number|2320416| |---|---| |Packing unit|1 pc| |Minimum order quantity|1 pc| |Sales key|CMU| |Product key|CMUEW3| |Catalog page|Page 338 (C-4-2019)| |GTIN|4046356707701| |Weight per piece (including packing)|10,025 g| |Weight per piece (excluding packing)|10,000 g| |Customs tariff number|85072080| |Country of origin|CN| Oct 24, 2024, 4:42 AM Page 1 (11) ## UPS-BAT/VRLA-WTR/24DC/13AH - Battery module 2320416 https://www.phoenixcontact.com/in/products/2320416 ## Technical data ## Notes General Note on the battery This product contains a battery with a limited shelf life that must be charged every few months. The product packaging indicates when the battery must be started up or recharged. The general shelf life can be found in the technical data area under “Latest startup”. ## Input data |put data|| |---|---| |Input voltage|24 V DC| |Buffer period|50 min. (10 A)| ||10 min. (40 A)| ## Output data |utput data|| |---|---| |Nominal output voltage|24 V DC| |Output current Imax|45 A| |Output fuse|2x 25 A ATOF 32V| |Connection in parallel|15| |Connection in series|no| |Battery operation|| |Nominal output voltage|24 V DC| |Nominal output current (IN)|45 A| ## Energy storage End-of-charge voltage 27.6 V (20 °C) Charging current 5.2 A Nominal capacity 13 Ah Latest startup date (battery only) 12 Months (0 °C ... 20 °C) Latest startup (battery only) - range 9 Months ... 12 Months (20 °C ... 30 °C) 6 Months ... 9 Months (30 °C ... 40 °C) Battery technology VRLA-WTR Memory medium Pure lead AGM Accumulator type Genesis G13EPX Number of cells 2 Size designation Block Battery pack yes IQ technology Yes Temperature sensor yes Suitable for fast charging yes Approved according to UL Style 3321150 °C 600 V AC 750 V DC Product properties Oct 24, 2024, 4:42 AM Page 2 (11) ## UPS-BAT/VRLA-WTR/24DC/13AH - Battery module 2320416 https://www.phoenixcontact.com/in/products/2320416 |Product type|Battery module| |---|---| |Product family|Battery module| |Application|for QUINT4 DC-UPS, QUINT4 AC-UPS, and QUINT-UPS| |Disposal|Used batteries must not be thrown away with household waste,| ||they should instead be disposed of in accordance with applicable| ||national regulations.| |IQ technology|Yes| |Data management status|| |Article revision|09| |Insulation characteristics|| |Protection class|III| |Degree of pollution|2| ## Dimensions |mensions|| |---|---| |Width|172 mm| |Height|177 mm| |Depth|178 mm| |Installation dimensions|| |Installation distance right/left|0 mm / 0 mm| |Installation distance top/bottom|50 mm / 50 mm| ## Mounting Mounting position Horizontally, on a mounting panel ## Material specifications |aterial specifications|| |---|---| |Housing material|Plastic| |Housing material|Metal| ## Cable/line |able/line|| |---|---| |Battery connecting cable: A+/-|| |Cable cross section|6 mm²| |Cable length|340 mm| |Color|red/black| |Battery connecting cable: B+/-|| |Cable cross section|6 mm²| |Cable length|110 mm| |Color|red/black| ## Environmental and real-life conditions |nvironmental and real-life conditions|| |---|---| |Ambient conditions|| |Degree of protection|IP20| |Ambient temperature (operation)|-25 °C ... 60 °C| Oct 24, 2024, 4:42 AM Page 3 (11) ## UPS-BAT/VRLA-WTR/24DC/13AH - Battery module ## 2320416 https://www.phoenixcontact.com/in/products/2320416 |Ambient temperature (storage/transport)|-40 °C ... 60 °C| |---|---| |Max. permissible relative humidity (operation)|≤ 95 %| |Shock|18 ms, 30g, in each space direction (according to IEC 60068-2-<br>27)| |Vibration (operation)|< 15 Hz, amplitude ±2,5 mm, 15 Hz ... 150 Hz, according to<br>IEC 60068-2-6| ||15 Hz ... 150 Hz, 2.3g, 90 min.| ## Standards and regulations |tandards and regulations|| |---|---| |Standard - Electrical safety|EN 62368-1/VDE 0868-1| |pprovals|| |Shipbuilding approval|DNV GL (EMC A), ABS| |UL approvals|UL/C-UL listed UL 508| ||UL/C-UL Recognized UL 60950-1| ## Approvals ## Ex data Suited for EX-applications no Oct 24, 2024, 4:42 AM Page 4 (11) ## UPS-BAT/VRLA-WTR/24DC/13AH - Battery module 2320416 https://www.phoenixcontact.com/in/products/2320416 ## Drawings ## Graphic **==> picture [356 x 181] intentionally omitted <==** **----- Start of picture text -----**<br> Buffertime<br>Minutes Hours<br>Load<br>Current 10 12 15 20 25 30 35 40 45 50 55 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20<br>1 A<br>2 A<br>3 A<br>5 A<br>7 A<br>10 A<br>15 A<br>20 A<br>The data is based on an ambient temperature of +25 °C at the start of use.<br>2320416 UPS-BAT/VRLA-WTR/24DC/13AH 2320429 UPS-BAT/VRLA-WTR/24DC/26AH<br>**----- End of picture text -----**<br> VRLA-WTR battery buffer times for TRIO DC UPS Graphic |Load<br>Current|Load<br>Current|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||Minutes|||||||||||Hours||||||||||||||| |||10|12|15|20|25|30|35|40|45|50|55|1|2|3|4|5|6|7|8|9|10|12|14|16|18|20| |1 A|||||||||||||||||||||||||||| |2 A|||||||||||||||||||||||||||| |3 A|||||||||||||||||||||||||||| |5 A|||||||||||||||||||||||||||| |7 A|||||||||||||||||||||||||||| |10 A|||||||||||||||||||||||||||| |15 A|||||||||||||||||||||||||||| |20 A|||||||||||||||||||||||||||| |25 A|||||||||||||||||||||||||||| |30 A|||||||||||||||||||||||||||| |35 A|||||||||||||||||||||||||||| |40 A|||||||||||||||||||||||||||| |The data is based on an ambient temperature of +25 °C at the start of use.<br>2320416UPS-BAT/VRLA-WTR/24DC/13AH<br>2320429UPS-BAT/VRLA-WTR/24DC/26AH|||||||||||||||||||||||||||| ||2320416UPS-BAT/VRLA-WTR/24DC/13AH||||||||||||||||||||||||||| VRLA-WTR battery buffer times for QUINT DC UPS Oct 24, 2024, 4:42 AM Page 5 (11) ## UPS-BAT/VRLA-WTR/24DC/13AH - Battery module 2320416 https://www.phoenixcontact.com/in/products/2320416 **==> picture [35 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Graphic<br>**----- End of picture text -----**<br> **==> picture [356 x 181] intentionally omitted <==** **----- Start of picture text -----**<br> Buffertime<br>Minutes Hours<br>Load<br>Current 1 2 3 5 10 20 30 40 45 50 1 2 3 5 8 10 15<br>15 W<br>35 W 2x<br>55 W 2x<br>90 W 2x<br>125 W 2x 2x<br>180 W 2x<br>275 W 2x<br>400 W 2x<br>2x: In this case, two battery modules of the same capacity are required. The data is based on an ambient temperature of +25 °C at the start of use.<br>2320416 UPS-BAT/VRLA-WTR/24DC/13AH 2320429 UPS-BAT/VRLA-WTR/24DC/26AH<br>**----- End of picture text -----**<br> **==> picture [368 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> 2x: In this case, two battery modules of the same capacity are required. The data is based on an ambient temperature of +25 °C at the start of use.<br>**----- End of picture text -----**<br> VRLA-WTR battery buffer times for QUINT AC UPS 500 VA Graphic |Load<br>Current|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime|Buffertime| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||Minutes|||||||||||||Hours||||||| ||1|2|3|4|5|8|10|15|20|25|30|40|50|1|1.5|2|3|4|6|9| |100 W|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x| |200 W|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x||| |300 W|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|||| |400 W|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x||||| |500 W|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|||||| |600 W|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|||||| |700 W|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x||||||| |800 W|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x||||||| |900 W|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|2x|||||||| **==> picture [367 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 2x: There are always two battery modules of the same capacity are required . The data is based on an ambient temperature of +25 °C at the start of use.<br>**----- End of picture text -----**<br> **==> picture [233 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> 2320416 UPS-BAT/VRLA-WTR/24DC/13AH 2320429 UPS-BAT/VRLA-WTR/24DC/26AH<br>**----- End of picture text -----**<br> VRLA-WTR battery buffer time for QUINT AC UPS 1 kVA Oct 24, 2024, 4:42 AM Page 6 (11) ## UPS-BAT/VRLA-WTR/24DC/13AH - Battery module 2320416 https://www.phoenixcontact.com/in/products/2320416 **==> picture [397 x 194] intentionally omitted <==** **----- Start of picture text -----**<br> Block diagram<br>DC 12V Battery<br>C DC 24V<br>DC 12V<br>**----- End of picture text -----**<br> Oct 24, 2024, 4:42 AM Page 7 (11) ## UPS-BAT/VRLA-WTR/24DC/13AH - Battery module 2320416 https://www.phoenixcontact.com/in/products/2320416 ## Approvals To download certificates, visit the product detail page: https://www.phoenixcontact.com/in/products/2320416 ||||||| |---|---|---|---|---|---| ||cUL Recognized<br>Approval ID: E211944||||| ||||||| ||UL Recognized<br>Approval ID: E211944||||| ||||||| ||IECEE CB Scheme<br>Approval ID: DK-29680-A1-M1-UL||||| ||||||| ||LR<br>Approval ID: LR22136091TA||||| ||||||| ||BV<br>Approval ID: 41516/B0|BV|||| ||||||| ||UL Listed<br>Approval ID: E123528||||| ||||||| ||cUL Listed<br>Approval ID: E123528||||| ||||||| |ABS|||||| |Approval ID: 22-2244289-PDA|||||| ||||||| |DNV|||||| |Approval ID: TAA0000265|||||| |||Nominal voltage UN|Nominal current IN|Cross section AWG|Cross section mm2| |||500 V|41 A|-|- 6| ||||||| ||cUL Listed<br>Approval ID: E199827||||| UL Listed Approval ID: E199827 Oct 24, 2024, 4:42 AM Page 8 (11) ## UPS-BAT/VRLA-WTR/24DC/13AH - Battery module 2320416 https://www.phoenixcontact.com/in/products/2320416 cULus Recognized cULus Listed cULus Listed Oct 24, 2024, 4:42 AM Page 9 (11) ## UPS-BAT/VRLA-WTR/24DC/13AH - Battery module 2320416 https://www.phoenixcontact.com/in/products/2320416 ## Classifications |ECLASS|| |---|---| |ECLASS-11.0|27050403| |ECLASS-13.0|27050403| |ECLASS-12.0|27050403| ## ETIM ||ETIM 9.0|EC000357| |---|---|---| ||NSPSC|| ||UNSPSC 21.0|26111700| ## UNSPSC Oct 24, 2024, 4:42 AM Page 10 (11) ## UPS-BAT/VRLA-WTR/24DC/13AH - Battery module 2320416 https://www.phoenixcontact.com/in/products/2320416 ## Environmental product compliance EU RoHS Fulfills EU RoHS substance requirements Yes Exemption 7(a), 7(c)-I China RoHS Environment friendly use period (EFUP) EFUP-15 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. EU REACH SVHC REACH candidate substance (CAS No.) Lead(CAS: 7439-92-1) SCIP 7902304d-daf4-4204-8ac6-a302a2dfdc49 Phoenix Contact 2024 © - all rights reserved https://www.phoenixcontact.com PHOENIX CONTACT (I) Pvt. Ltd. A-58/2, Okhla Industrial Area, Phase - II, New Delhi-110 020 +91.1275.71420 info@phoenixcontact.co.in Oct 24, 2024, 4:42 AM Page 11 (11)
Updated at June 4, 2026
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →