2308098
CURRENT SENS, CURRENT O/P, 0-600A, 150MS
- Manufacturer: PHOENIX CONTACT
- Product type: Current Sensors
- SVHC: No SVHC (04-Feb-2026)
- Accuracy: ± 1%
- Accuracy %: 1%
- Product Range: -
- Response Time: 150ms
- Primary Current: 600A
- Sensor Mounting: DIN Rail
- Measured Current: AC / DC
- Sensor Output Type: Current
- Supply Voltage Range: 20V DC to 30V DC
- Secondary Signal Type: 4mA to 20mA
- Supply Voltage DC Max: 30V
- Supply Voltage DC Min: 20V
- Current Sensor Technology: -
- Operating Temperature Max: 65°C
- Operating Temperature Min: -40°C
- Current Measuring Range AC: 0A to 600A
- Current Measuring Range DC: 0A to 600A
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 242.44 € |
| Current stock | 10+ |
| Lead time | 30 days |
https://www.phoenixcontact.com/gb/products/2308098 ## Universal current transducer - MCR-SL-CUC-600-I - 2308098 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Universal current transducer, for measuring DC, AC, and distorted currents, 0 ... 600 A input current, 4 ... 20 mA output ## Your advantages - Variable mounting on DIN rail and mounting plate Simple connection technology thanks to COMBICON plug-in connection terminal blocks - Compact dimensions also enable distributed use - 3-way isolation Universal current measurement, no shunt required ## Key Commercial Data Packing unit 1 pc ~~Oc~~ GTIN ~~ME a~~ GTIN 4046356566988 Weight per Piece (excluding packing) 293.300 g ~~Oc I~~ Custom tariff number 90303370 Country of origin ~~en~~ China ## Technical data ## Dimensions |Width|90 mm| |---|---| |Height|33.8 mm| |Depth|85 mm| |Primary round conductor (diameter)|32 mm| |Ambient conditions|| |Ambient temperature (operation)|-40 °C ... 65 °C| |Ambient temperature (storage/transport)|-40 °C ... 85 °C| |Degree of protection|IP20| ## Ambient conditions 02/27/2020 Page 1 / 5 https://www.phoenixcontact.com/gb/products/2308098 ## Universal current transducer - MCR-SL-CUC-600-I - 2308098 ## Technical data ## Ambient conditions |Noise immunity|EN 61000-6-2| |---|---| |Input data|| |Number of inputs|1| |Input current range|0 A ... 600 A| |Overload capacity|3 x IIN| |Frequency measuring range|20 Hz ... 6000 Hz (0 Hz)| |Connection method|Cable design: 32 mm diameter| |Rated frequency: Standard converter|20 Hz ... 6000 Hz| |Primary rated current Ipn|600 A| |Output data|| |---|---| |Output name<br>Current output<br>Current output signal<br>4 mA ... 20 mA<br>Max. output current<br>< 25 mA<br>Load/output load current output<br>< 300 Ω<br>Switching output<br>Output name<br>No switching output<br>~~=~~|| |Power supply|| |Nominal supply voltage<br>24 V DC<br>Supply voltage range<br>20 V DC ... 30 V DC<br>Max. current consumption<br>(30 + IOUT) mA<br>~~—~~|| |Connection data|| |Connection method|Push-in connection| |Stripping length|10 mm| |Conductor cross section solid|0.25 mm² ... 2.5 mm²| |Conductor cross section flexible|0.2 mm² ... 2.5 mm²| |Conductor cross section AWG|24 ... 12| |General|| |Accuracy class<br>1<br>Maximum transmission error<br><± 1 % (of final value)<br>Temperature coefficient, typical<br>0.02 %/K (0 ... 60 °C)<br>0.04 %/K (-40 °C ... 65 °C)<br>Linearity error<br><± 1 % (From the range end value)<br>Step response (10-90%)<br>150 ms<br>Overvoltage category<br>III<br>Degree of pollution<br>2<br>Rated insulation voltage<br>300 V AC<br>Test voltage input/output<br>3.5 kV (50 Hz, 1 min.)<br>Test voltage input/power supply<br>3.5 kV (50 Hz, 1 min.)<br>~~a=~~|| ||02/27/2020 Page 2 / 5| https://www.phoenixcontact.com/gb/products/2308098 ## Universal current transducer - MCR-SL-CUC-600-I - 2308098 ## Technical data ## General |Noise emission|EN 61000-6-4| |---|---| |Noise immunity|EN 61000-6-2| |Color|green| |Housing material|Frianyl B63 V0 GV30| |Conformance|CE-compliant| ## Standards and Regulations |Noise immunity<br>Color<br>Housing material<br>Conformance<br>Standards and Regulations|EN 61000-6-2<br>green<br>Frianyl B63 V0 GV30<br>CE-compliant| |---|---| |Noise emission|EN 61000-6-4| |Noise immunity|EN 61000-6-2| |Conformance|CE-compliant| |Conformance/approvals|| |Designation<br>CE<br>Identification<br>CE-compliant<br>~~eT~~|| |Environmental Product Compliance|| |China RoHS|Environmentally Friendly Use Period = 25;| ||For details about hazardous substances go to tab “Downloads”,| ||Category “Manufacturer's declaration”| ## Drawings ## Dimensional drawing 02/27/2020 Page 3 / 5 https://www.phoenixcontact.com/gb/products/2308098 ## Universal current transducer - MCR-SL-CUC-600-I - 2308098 Circuit diagram **==> picture [78 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Schematic diagram<br>**----- End of picture text -----**<br> ## Classifications ## eCl@ss |eCl@ss 4.0|eCl@ss 4.0|27210900| |---|---|---| |eCl@ss 4.1|eCl@ss 4.1|27210900| |eCl@ss 5.0|eCl@ss 5.0|27210900| |eCl@ss 5.1|eCl@ss 5.1|27210900| |eCl@ss 6.0|eCl@ss 6.0|27210900| |eCl@ss 7.0|eCl@ss 7.0|27210902| |eCl@ss 8.0|eCl@ss 8.0|27210902| |eCl@ss 9.0|eCl@ss 9.0|27210902| 02/27/2020 Page 4 / 5 https://www.phoenixcontact.com/gb/products/2308098 ## Universal current transducer - MCR-SL-CUC-600-I - 2308098 ## Classifications ETIM ETIM 3.0 EC002048 ETIM 4.0 EC002048 ETIM 5.0 EC002048 ETIM 6.0 EC002048 ETIM 7.0 EC002048 ~~SSS~~ UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121032 UNSPSC 18.0 39121032 UNSPSC 19.0 39121032 UNSPSC 20.0 39121032 UNSPSC 21.0 39121032 ~~——~~ Approvals Approvals Approvals EAC Ex Approvals Approval details **==> picture [528 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> EAC RU*DE.*08.B.01852-19<br><br>—<br>Phoenix Contact 2020 © - all rights reserved<br>http://www.phoenixcontact.com<br>**----- End of picture text -----**<br> 02/27/2020 Page 5 / 5
Updated at April 29, 2026
Phoenix Contact is a global leader in industrial connection technology, automation systems, and electronic interface solutions. With decades of engineering heritage originating in Germany, the company develops robust components designed to ensure reliable power, data, and signal transmission across demanding manufacturing and industrial environments. The cornerstone of the Phoenix Contact portfolio is its industry-leading selection of connection technologies. The range features an exceptional variety of terminal blocks, including pluggable headers and sockets, highly reliable wire-to-board solutions, and versatile DIN rail terminal blocks. These foundational connectivity components are supported by a comprehensive ecosystem of power distribution blocks, interface modules, marking systems, and accessories engineered for seamless control cabinet wiring. Beyond physical connectivity, Phoenix Contact provides critical components for advanced automation, control, and system protection. The wider offering encompasses a broad spectrum of process controllers, high-efficiency AC/DC converters, and a comprehensive suite of power, safety, and solid-state relays. From precision signal converters and electronic circuit breakers to fiber optic cable assemblies, Phoenix Contact equips engineers with the high-performance technologies required to build secure, highly efficient, and future-ready industrial systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →