Image not available
Illustrative purposes only
1839260000
PCB TERMINAL 10.16 MM
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: WEIDMULLER / PARTNER STOCK
- Product type: Pluggable Terminal Block Headers & Sockets
- SVHC: No SVHC (07-Nov-2024)
| Delivery and price | |
|---|---|
| Units per pack | 150 |
| Price | 2.1 € |
| Current stock | 1000+ |
| Lead time | 30 days |
**Data sheet** ## **LUP 10.16/01/90 3.2SN GY BX** **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com ## **Product image** This PCB terminal provides connections for 1000 V, test point, 76 A and 16 mm² conductor cross-section with proven clamping yoke connection at 10.16 mm pitch, conductor outlet direction in 90° design. ## **General ordering data** |Version|Printed circuit board terminals, 10.16 mm,| |---|---| ||Number of poles: 1, 90°, Solder pin length (l):| ||3.2 mm, tinned, Pebble grey, Clamping yoke| ||connection, Clampingrange, max. : 16 mm², Box| |Order No.|1839260000| |Type|LUP 10.16/01/90 3.2SN GY BX| |GTIN(EAN)|4032248349760| |Qty.|20pc(s).| |Product data|IEC: 1000 V / 76 A / 0.5 - 16 mm²| ||UL: 300 V/58 A/AWG 26 - AWG 6| |Packaging|Box| Creation date December 4, 2023 1:22:41 PM CET Catalogue status 24.11.2023 / We reserve the right to make technical changes. 1 **Data sheet** — **LUP 10.16/01/90 3.2SN GY BX** ## **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany ## **Technical data** ~~Ld~~ ~~a~~ www.weidmueller.com ## **Dimensions and weights** |Depth|25.1 mm|Depth(inches)|0.988 inch| |---|---|---|---| |Height|34.7 mm|Height(inches)|1.366 inch| |Height of lowest version|31.5 mm|Width|10.96 mm| |Width (inches)|0.431 inch|Net weight|10.35 g| |**System parameters**|||| |Product family|OMNIMATE Power - series|Wire connection method|| ||LUP||Clamping yoke connection| |Mountingonto the PCB|THT solder connection|Conductor outlet direction|90°| |Pitch in mm(P)|10.16 mm|Pitch in inches(P)|0.4 inch| |Number ofpoles|1|Pin seriesquantity|1| |Fitted bycustomer|Yes|Number of rows|1| |Max. adjacentpolesper row|12|Solderpin length(l)|3.2 mm| |Solderpin dimensions|1.2 x 1.2 mm|Solder eyelet hole diameter(D)|1.6 mm| |Solder eyelet hole diameter tolerance(D)<br>+ 0,1 mm||Number of solderpinsperpole|2| |Screwdriver blade|1.0 x 5.5,PZ 2|Screwdriver blade standard|DIN 5264| |Tighteningtorque,min.|1.2 Nm|Tighteningtorque,max.|1.5 Nm| |Clampingscrew|M 4|Strippinglength|12 mm| |L1 in mm|0 mm|L1 in inches|0 inch| |Touch-safe protection acc. to DIN VDE|IP20 plugged/ IP10|Touch-safe protection acc. to DIN VDE|| |0470|unplugged|57 106|Safe from finger touch| |Protection degree|IP20|Volume resistance|0.50 mΩ| |**Material data**|||| |Insulatingmaterial|Wemid(PA)|Colour|Pebblegrey| |Colour chart(similar)|RAL 7032|Insulatingmaterialgroup|I| |Comparative TrackingIndex(CTI)|≥ 600|UL 94 flammabilityrating|V-0| |Contact material|E-Cu|Contact surface|tinned| |Layer structure of solder connection|1.5...3 µm Ni / 4...6 µm Sn|Storage temperature, min.|| ||matt||-40 °C| |Storage temperature,max.|70 °C|Operatingtemperature,min.|-50 °C| |Operatingtemperature,max.|120 °C|Temperature range,installation,min.|-25 °C| |Temperature range, installation, max.|120 °C||| ## **Conductors suitable for connection** |Clampingrange,min.|0.13 mm²| |---|---| |Clampingrange,max.|16 mm²| |Wire connection cross section AWG,|AWG 22| |min.|| |Wire connection cross section AWG,|AWG 6| |max.|| |Solid,min. H05(07)V-U|0.5 mm²| |Solid,max. H05(07)V-U|16 mm²| |Stranded,min. H07V-R|6 mm²| |Stranded,max. H07V-R|16 mm²| |Flexible,min. H05(07)V-K|0.5 mm²| |Flexible,max. H05(07)V-K|16 mm²| |w. plastic collar ferrule, DIN 46228 pt 4,|2.5 mm²| |min.|| |w. plastic collar ferrule, DIN 46228 pt 4,|10 mm²| |max.|| |w. wire end ferrule, DIN 46228 pt 1,|2.5 mm²| |min.|| Creation date December 4, 2023 1:22:41 PM CET Catalogue status 24.11.2023 / We reserve the right to make technical changes. 2 **Data sheet** — **LUP 10.16/01/90 3.2SN GY BX** ## **Weidmüller Interface GmbH & Co. KG** |||||Klingenbergstraße 26|| |---|---|---|---|---|---| |||||D-32758 Detmold|| |||||Germany|| |**Technical data**<br>~~Ld~~||||www.weidmueller.com<br>~~a~~|| ||w. wire end ferrule, DIN 46228 pt 1,|w. wire end ferrule, DIN 46228 pt 1,|10 mm²||| ||max.||||| ||Plug gauge in accordance with EN||5.4 mm x 5.1 mm; 5.3 mm||| ||60999 a x b;ø||||| ||Clampable conductor||Cross-section for conductor connection|Cross-section for conductor connection<br>Type<br>fine-wired|| |||||nominal<br>2.5 mm²|| |||wire end ferrule<br>Strippinglength<br>nominal<br>12 mm<br>Recommended wire-<br>end ferrule<br>H2,5/12<br>Strippinglength<br>nominal<br>14 mm<br>Recommended wire-<br>end ferrule<br>H2,5/19D BL<br>Cross-section for conductor connection<br>Type<br>fine-wired<br>nominal<br>4 mm²<br>wire end ferrule<br>Strippinglength<br>nominal<br>12 mm<br>Recommended wire-<br>end ferrule<br>H4,0/12<br>Strippinglength<br>nominal<br>14 mm<br>Recommended wire-<br>end ferrule<br>H4,0/20D GR<br>Cross-section for conductor connection<br>Type<br>fine-wired<br>nominal<br>6 mm²<br>wire end ferrule<br>Strippinglength<br>nominal<br>12 mm<br>Recommended wire-<br>end ferrule<br>H6,0/12<br>Strippinglength<br>nominal<br>14 mm<br>Recommended wire-<br>end ferrule<br>H6,0/20 SW<br>~~ee~~<br>~~——~~<br>PF<br>~~} —___1___~~<br>~~——~~<br>PF<br>~~/}—______l__~~<br>~~——~~|||| ||||Cross-section for conductor connection<br>Type<br>fine-wired<br>nominal<br>10 mm²<br>wire end ferrule<br>Strippinglength<br>nominal<br>15 mm<br>Recommended wire-<br>end ferrule<br>H10,0/22 EB<br>Strippinglength<br>nominal<br>12 mm<br>Recommended wire-<br>end ferrule<br>H10,0/12<br>~~eee~~<br>~~/} —_____1____~~<br>~~=~~||| ||Reference text||Length of ferrules is to be chosen depending on the product and the rated voltage., The outside||| ||||diameter of the plastic collar should not be larger than the pitch (P)|diameter of the plastic collar should not be larger than the pitch (P)|| ||**Rated data acc. to IEC**||||| ||tested acc. to standard|||Rated current, min. number of poles|| ||||IEC 60664-1,IEC 61984|(Tu=20°C)<br>76 A|| ||Rated current, max. number of poles|||Rated current, min. number of poles|| ||(Tu=20°C)||72 A|(Tu=40°C)<br>72 A|| ||Rated current, max. number of poles|||Rated voltage for surge voltage class /|| ||(Tu=40°C)||62 A|pollution degree II/2<br>1,000 V|| ||Rated voltage for surge voltage class /|||Rated voltage for surge voltage class /|| ||pollution degree III/2||1,000 V|pollution degree III/3<br>800 V|| ||Rated impulse voltage for surge voltage|||Rated impulse voltage for surge voltage|| ||class/ pollution degree II/2||6 kV|class/ pollution degree III/2<br>8 kV|| ||Rated impulse voltage for surge voltage|||Short-time withstand current resistance|| ||class/ contamination degree III/3||8 kV|1 x 1s with 700 A|| Creation date December 4, 2023 1:22:41 PM CET Catalogue status 24.11.2023 / We reserve the right to make technical changes. 3 **Data sheet** ## **LUP 10.16/01/90 3.2SN GY BX** **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany ~~a~~ www.weidmueller.com ||||Germany<br>www.weidmueller.com|www.weidmueller.com| |---|---|---|---|---| |**Technical data**<br>~~ass~~|||www.weidmueller.com<br>~~a~~|www.weidmueller.com<br>~~a~~| ||**Rated data acc. to CSA**|||| ||Institute (CSA)|Co|Certificate No. (CSA)|200039-1198743| ||Rated voltage(UsegroupB/CSA)<br>300 V||Rated voltage(UsegroupC/CSA)|300 V| ||Rated voltage(UsegroupD/CSA)<br>600 V||Rated current(UsegroupB/CSA)|58 A| ||Rated current(UsegroupC/CSA)<br>58 A||Rated current(UsegroupD/CSA)|5 A| ||Wire cross-section,AWG,min.|AWG 22|Wire cross-section,AWG,max.|AWG 6| ||Reference to approval values|Specifications are||| |||maximum values, details -||| |||see approval certificate.||| ## **Rated data acc. to UL 1059** |**Rated data acc. to UL 1059**||||| |---|---|---|---|---| |Institute (cURus)|cWAkus||Certificate No. (cURus)|E60693| |Rated voltage(UsegroupB/UL 1059)||300 V|Rated voltage(UsegroupC/UL 1059)|300 V| |Rated voltage(UsegroupD/UL 1059)||600 V|Rated current(UsegroupB/UL 1059)|58 A| |Rated current(UsegroupC/UL 1059)||58 A|Rated current(UsegroupD/UL 1059)|5 A| |Wire cross-section,AWG,min.||AWG 26|Wire cross-section,AWG,max.|AWG 6| |Reference to approval values||Specifications are||| |||maximum values, details -||| |||see approval certificate.||| |**Packing**||||| |Packaging||Box|VPE length|114 mm| |VPE width||77 mm|VPE height|53 mm| |**Type tests**||||| |||||| |Test: Durability of markings||Standard|DIN EN 61984 section 7.3.2 / 09.02 taking|| ||||pattern from DIN EN 60068-2-70|attern from DIN EN 60068-2-70/07.96| |||Test|mark of origin, type identification, type of|| ||||material,approval markingUL,durability|| |||Evaluation|available|| Creation date December 4, 2023 1:22:41 PM CET Catalogue status 24.11.2023 / We reserve the right to make technical changes. 4 **Data sheet** — **LUP 10.16/01/90 3.2SN GY BX** **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany |**Technical data**<br>~~Ld~~|www.weidmueller.com<br>~~a~~|www.weidmueller.com<br>~~a~~| |---|---|---| |Test: Clampable cross section|Standard<br>DIN EN 60999-1 section 7 and 9.1 / 12.00, DIN<br>EN 60947-1 section 8.2.4.5.1/12.02|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>solid 0.5 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>stranded 0.5 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>solid 16 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>stranded 16 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 22/1| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 22/19| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 6/7| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 6/19| ||Evaluation<br>passed|| |Test for damage to and accidental<br>loosening of conductors|Standard<br>DIN EN 60999-1 section 9.4/12.00|| ||Requirement<br>0.2 kg|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>AWG 22/1| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 22/19| ||Evaluation<br>passed|| ||Requirement<br>0.3 kg|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>solid 0.5 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>stranded 0.5 mm²| ||Evaluation<br>passed|| ||Requirement<br>2.9 kg|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>solid 16 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>stranded 16 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 6/7| ||Evaluation<br>passed|| Creation date December 4, 2023 1:22:41 PM CET Catalogue status 24.11.2023 / We reserve the right to make technical changes. 5 **Data sheet** — **LUP 10.16/01/90 3.2SN GY BX** ## **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany ## ~~a~~ www.weidmueller.com ## **Technical data** ~~Ld~~ Pull-out test |Pull-out test|Standard<br>DIN EN 60999-1 section 9.5/12.00|Standard<br>DIN EN 60999-1 section 9.5/12.00| |---|---|---| ||Requirement<br>≥15 N|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>AWG 22/1| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 22/19| ||Evaluation<br>passed|| ||Requirement<br>≥20 N|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>H05V-U0.5| |||Type of conductor<br>and conductor cross-<br>section<br>H05V-K0.5| ||Evaluation<br>passed|| ||Requirement<br>≥100 N|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>H07V-K16| |||Type of conductor<br>and conductor cross-<br>section<br>H07V-U16| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 6/7| ||Evaluation<br>passed|| Creation date December 4, 2023 1:22:41 PM CET Catalogue status 24.11.2023 / We reserve the right to make technical changes. 6 **Data sheet** ## **LUP 10.16/01/90 3.2SN GY BX** **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany ## **Technical data** ~~ass~~ ~~a~~ www.weidmueller.com ## **Important note** - IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request. - Notes • Additional variants on request • Rated current related to rated cross-section & min. No. of poles. • Wire end ferrule without plastic collar to DIN 46228/1 • Wire end ferrule with plastic collar to DIN 46228/4 • The data given under CSA relates to a cUL approval - E60693 • P on drawing = pitch - Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. - The test point can only be used as potential-pickup point. - Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months ## **Approvals** |**Approvals**|| |---|---| |Approvals|@cALis| |ROHS|Conform| |UL File Number Search|UL Website| |Certificate No. (cURus)|E60693| |**Downloads**|| |EngineeringData|CAD data--STEP| |Product Change Notification|20220201 Visual change OMNIMATE® Power PCB terminal blocks and connectors| ||20220201 Visuelle Änderung OMNIMATE® Power Leiterplattenklemmen und-steckverbinder| |Catalogues|Catalogues in PDF-format| |Brochures|FL DRIVES EN| ||FL DRIVES DE| Creation date December 4, 2023 1:22:41 PM CET Catalogue status 24.11.2023 / We reserve the right to make technical changes. 7 **Data sheet** ## **LUP 10.16/01/90 3.2SN GY BX** **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com ## **Drawings** ## **Product image** **Graph** ## **Dimensional drawing** **Graph** Creation date December 4, 2023 1:22:41 PM CET Catalogue status 24.11.2023 / We reserve the right to make technical changes. 8 ## **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com ## **Single Wave:** **==> picture [432 x 446] intentionally omitted <==** **----- Start of picture text -----**<br> Contact time appr. 3 sec.<br>260 255 °C o s , 260 °C<br>240 250 °C I ~,.N\<br>\ [‘]<br>220 \\ [N] N [N] N<br>LON<br>200180 .\1\\ [.][N] SS\SsN.<br>160 \\\Str ‘\‘S‘S<br>wT “oy, “w<br>140 od° oNs\ "he,a> S.ss<br>12010080 Preheating :o.;7” .’Pua&&Pia4.-As-A.ue<ormeee7eeerrccCi7”Y11hae.~s- 7 appr. 150 °C \ny\\ny\\‘ wy£2.2>""y“ Cooling rate < 6 °K/s SS“>soy.‘s>“sDo~aTa“ss—m~. =~areTaaaooo-<br>;Fe ./4 -.- S.‘<br>6040 ¢Fa¢?me47soMosenooheSa--o “7“7“ ‘‘‘s.SS —=a-. Typical process Prozess limits<br>20 Sa Heating rate < 3 °K/s “es Temperature on board<br>0<br>0 20 40 60 80 100 120 140 160 180 200 220 240<br>time [s]<br>Double Wave:<br>260 255 °C — 260 °C<br>Total contact time max. 10 sec. Q 250 °C<br>240<br>220<br>200<br>180<br>\<br>160 eee sue\\<br>140120100 Preheating a?’.a”oa a..ue °°&.SS£ 7*.“eS?ny“ocd;7 appr. 150°C [RO\‘\‘\‘‘ NS>NOS.°WSesyO~~>-°°~~ ~~~<br>8060 a?-o7747 *Aefre/&°oo&&4aea7”’ \‘‘‘‘\ Cooling rate < 6 °K/s ‘‘ >cS““Sse°“asD>,-_;-:<br>o* A. “ Typical process<br>40 Prie"7-- neeiteer<r — Process limits<br>20 Heating rate < 3 °K/s Temperature on board<br>0<br>0 20 40 60 80 100 120 140 160 180 200 220 240<br>time [s]<br>Temperature [°C]<br>Temperature [°C]<br>**----- End of picture text -----**<br> ## Wired connection elements should be processed in accordance with the DIN EN 61760-1 standard. We have included two recommendations for practical wave soldering profiles, with which Weidmüller PCB terminals and connectors are qualified. - PCB thickness - Proportion of Cu in the layers - Single/double-sided assembly - Product range - Heating and cooling rates soldering temperature of 260°C. In practice, the maximum soldering temperature is quite often well below the above maximum profile. We reserve the right to make technical changes.
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →