Image not available
Illustrative purposes only
170M6464
INDUSTRIAL AND POWER
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON / PARTNER STOCK
- Product type: Industrial & Electrical Power Fuses
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 823.83 € |
| Current stock | 10+ |
| Lead time | 30 days |
Volume 4C: Circuit Protection Bussmann series solutions
## **Don't miss a sale or an opportunity to upgrade your fuse protection**
Three tiers offer distinct levels of circuit protection
1. Ultimate - Unique element designs deliver a powerful combination of operating characteristics in one fuse — fast shortcircuit protection, current limitation, and time-delay with up to 300 kA interrupting ratings.
2. Advanced - Choose between fast-acting, short-circuit, current limiting protection or time-delay energy efficient, current limiting protection based on the application with 200 kA interrupting ratings.
3. Basic - Basic single-element protection for service, feeder and branch circuit applications with up to 100 kA interrupting ratings.
The arrows below show you the way
CUBEFuse™ protection
For finger-safe protection in a small footprint up to 600 V and 100 A, upgrade to the time-delay or fast-acting CUBEFuse. Amp rating rejection feature helps prevent overfusing in the CUBEFuse holder (page 1-11) or CCP2-CF UL 98 disconnect switch (page 11-6).
**==> picture [500 x 564] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ultimate Advanced Advanced Basic<br>FRN-R-(amp) NON-(amp)<br>Class RK5 - 250 V Class H(K) - 250 V<br>See page 1-23 See page 1-15<br>LPN-RK-(amp)SP<br>Class RK1 - 250 V KTN-R-(amp)<br>Class RK1 - 250 V<br>See page 1-18<br>See page 1-21<br>FRS-R-(amp)<br>Class RK5 - 600 V<br>See page 1-23<br>, clei<br>NOS-(amp)<br>LPS-RK-(amp)SP Class H(K) - 600 V<br>Class RK1 - 600 V See page 1-15<br>See page 1-18 KTS-R-(amp)<br>=——S_ Class RK1 - 600 V . |<br>FCF(amp) See page 1-21<br>Class CF fast-acting<br>finger-safe CUBEFuse up<br>to 100 A with amp rating<br>rejecting holders to help<br>prevent overfusing<br>See page 1-9<br>LPJ-(amp)SP JKS-(amp)<br>Class J time-delay Class J fast-acting<br>See page 1-13 See page 1-14<br>TCF(amp)<br>Class CF time-delay : < z<br>Finger-safe CUBEFuse up<br>to 100 A with amp rating<br>ii ii =><br>rejecting holders to help LP-CC-(amp) FNQ-R-(amp)* KTK-R-(amp)<br>prevent overfusing Class CC time-delay Class CC time-delay Class CC fast-acting<br>See page 1-8 See page 1-5 See page 1-6 See page 1-7<br>—<br>KRP-C-(amp)SP<br>KTU-(amp) KLU-(amp)<br>Class L time-delay<br>Class L fast-acting Class L time-delay<br>See page 1-16<br>See page 1-17 See page 1-18<br>**----- End of picture text -----**<br>
- FNQ-R fuses are suggested on primary of control transformers - do NOT upgrade to LP-CC.
**Introduction**
## Contents
## **The power of space**
|Description|Catalog section|
|---|---|
|Selecting fused circuit protection|Introduction|
|Low voltage branch circuit fuses|1|
|Low voltage supplemental fuses and limiters|2|
|Electronic, PCB and small dimension fuses|3|
|High speed fuses|4|
|IEC and British Standard fuses|5|
|Photovoltaic fuses, holders and blocks|6|
|Medium voltage fuses|7|
|Fuse blocks and holders|8|
|Power distribution and terminal blocks|9|
|Connector products<br>Disconnect switches<br>Quik-Spec™ electrical gear|10<br>11<br>12|
|Surge protective devices<br>Telecom protection products<br>Accessories|13<br>14<br>15|
|Fuse sizing for 600 V building electrical systems||
|Selective coordination||
|Low voltage, branch circuit fuse types and classes<br>Glossary of common electrical terms|16|
|Electrical formulas||
|Fuse and fuse block cross reference||
|Catalog number index||
|Low-Peak™ Upgrade program and fuse inventory<br>consolidation|Inside back cover|
Bussmann series circuit protection solutions comply with major industrial standards and agency requirements such as: BS, IEC, DIN, UL, NEMA, CSA, CE, C-UL, etc. and are manufactured at facilities that are ISO 9000 certified.
This catalog is intended to present product data and provide technical information that will help the end user with design application. Eaton reserves the right, without notice, to change design or construction or any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this catalog. Once a product has been selected, it should be tested by the user in all possible applications. Further, Eaton takes no responsibility for errors or omissions contained in this catalog, or for misapplication of any Eaton product. Extensive product information is available in the Eaton product data sheets available on line at Eaton.com/bussmannseries.
©2018 Eaton
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
i
**Introduction**
## Selecting fused circuit protection
The following fuse selection tables are based on the 2017 NEC and provide fuse recommendations for the listed applications.
These are only suggestions. Final fuse selection should be performed by qualified personnel able to fully assess an application's circuit protection requirements.
Application Engineering can be reached via phone (toll-free 855-2877626 ) and email (FuseTech@Eaton.com).
To locate the recommended fuse product pages, use the index starting on page 16-4.
If you need assistance in selecting a fuse, contact the Eaton Application Engineering team Monday through Friday, 7:00 a.m. — 5:00 p.m. Central time.
## Ballasts
**==> picture [537 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
Location Type Notes Fuse recommendation Fuse holder recommendation<br>Consult fixture manufacturer for size GLR, GMF, GRF HLR<br>Fluorescent<br>and type GLQ, GMQ HLQ<br>BAF, KTK, FNM, FNQ HPF, HPS<br>KTK-R, FNQ-R, LP-CC HPS-RR, HPF-RR<br>Indoor<br>All other (mercury, Consult fixture manufacturer for size BBS HPS-L, HPF-L<br>sodium, etc.) and type SC up to 15 amps HPF-EE, HPS-EE<br>SC 20 amp HPF-JJ, HPS-JJ<br>SC 25-30 amps HPF-FF, HPS-FF<br>Consult fixture manufacturer for size BAF, KTK, FNM, FNQ HEB, HEX, HPC-D<br>Outdoor Mercury, sodium, etc.<br>and type. KTK-R, FNQ-R, LP-CC HEY, HEZ<br>**----- End of picture text -----**<br>
## Capacitors (NEC 460)
**==> picture [537 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protected by Sizing Fuse/volt recommendation<br>Up to 250 V: LPN-RK_SP, FRN-R<br>Time-delay fuses 150% to 175% of Full Load Current (FLC)<br>Up to 600 V: LPS-RK_SP, FRS-R, LPJ_SP, LP-CC, FNQ-R, TCF<br>Up to 250 V: KTN-R<br>Non time-delay fuses 250% to 300% of Full Load Current (FLC) Up to 300 V: JJN<br>Up to 600 V: KTS-R, JKS, KTK-R, JJS, FCF_RN<br>On loadside of motor<br>—<br>running overcurrent Protection recommended as shown, but not required<br>device<br>**----- End of picture text -----**<br>
## Electric heat (NEC 424)
**==> picture [537 x 76] intentionally omitted <==**
**----- Start of picture text -----**<br>
Heating type Sizing Fuse/volt recommendation<br>125% or next size larger but in no case larger than 60 Up to 250 V: LPN-RK_SP, FRN-R, NON<br>Space heating<br>amps for each subdivided load<br>Up to 300 V: JJN<br>Boilers (ASME Up to 480 V; SC 25 to SC 60<br>125% or next size larger but in no case larger than 150<br>rated and stamped<br>vessel) amps for each subdivided load Up to 600 V: LPS-RK_SP, FRS-R, NOS, JJS, LPJ_SP, LP-CC,<br>FNQ-R, JKS, KTK-R, TCF, SC 1/2 to SC 20, FCF_RN<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
ii
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Introduction**
Mains, feeders, branches (NEC 430)
**==> picture [537 x 216] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuit type Circuit loads Sizing Fuse/volt recommendation<br>Up to 250 V: LPN-RK_SP, FRN-R<br>No motor load 100% of non-continuous load plus 125% of continuous load Up to 300V: JJN<br>Up to 600 V: LPS-RK_SP, FRS-R, JJS,<br>LPJ_SP, LP-CC, JKS, KTK-R<br>150% of the FLA of largest motor (if there are two or more<br>motors of same size, one is considered to be the largest)<br>Feeder circuits ≤ 600 A Combination motor and other loads plus the sum of all the FLA for all other motors plus 100% of non-continuous, non-motor load plus 125% of continuous, non-motor load. A maximum of 175% (or the next standard size if<br>175% does not correspond to a standard size) is allowed for all Up to 250 V: LPN-RK_SP, FRN-R<br>but wound rotor and all DC motors.<br>Up to 600 V: LPS-RK_SP, FRS-R,<br>150% of the FLA of largest motor (if there are two or more LPJ- SP, LP-CC<br>motors of same size, one is considered to be the largest) plus<br>the sum of all the FLA for all other motors. A maximum of<br>Motor loads<br>175% (or the next standard size if 175% does not correspond<br>to a standard size) is allowed for all but wound rotor and all DC<br>motors.<br>Main, branch<br>and feeder — 150% to 225% of full load current of largest motor plus 100%<br>circuits of full load current of all other motors plus 125% of continuous Up to 600 V: KRP-C_SP<br>non-motor load plus 100% of non-continuous non-motor load<br>(601-6000 A)<br>**----- End of picture text -----**<br>
Motor loads (NEC 430)
**==> picture [537 x 286] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuit voltage Fuse type Fuse sized for Sizing Fuse/volt recommendation<br>Up to 250 V: FRN-R<br>125% of motor FLA or next size larger<br>Backup overload with Up to 600 V: FRS-R<br>motor starter and short-<br>circuit protection Up to 250 V: LPN-RK_SP<br>130% of motor FLA or next size larger<br>Up to 600 V: LPS-RK_SP<br>Time-delay 175% of motor FLA or next size larger. (If<br>fuses 175% does not correspond to a standard<br>size). If this will not allow motor to start, Up to 250 V: LPN-RK_SP, FRN-R<br>due to higher than normal inrush currents<br>Short-circuit only or longer than normal acceleration times (5 Up to 600 V: LPS-RK_SP, FRS-R,<br>600 V and less seconds or greater), fuse may be sized up to LPJ_SP, TCF<br>225% or next size smaller. NOTE: 150% for<br>wound rotor and all DC motors.<br>Maximum of 300% of motor FLA or next<br>size larger (if 300% does not correspond to<br>a standard size). If this will not allow motor Up to 250 V: KTN-R<br>Non-time delay to start due to higher than normal inrush<br>and all Class Short-circuit only currents or longer than normal acceleration Up to 300 V: JJN<br>CC fuses times (5 seconds or greater), fuses through Up to 600 V: KTS-R, JJS, LP-CC, JKS,<br>600 amps may be sized up to 400% or next KTK-R, FCF_RN<br>size smaller. Note: 150% for wound rotor<br>and all DC motors.<br>Compare the minimum melting time-current Up to 2400 V: JCH, JCK, JCK-A,<br>characteristics of the fuses with the time-<br>JCK-B, 2ACLS, 2BCLS, 2CLS, 2HCLS<br>current characteristics of the overload relay<br>Above 600 V — — curve. The size fuse which is selected Up to 4800 V: JCL, JCL-A, JCL-B,<br>should be such that short-circuit protection 5ACLS, 5BCLS, 5CLS, 5HCLS<br>is provided by the fuse and overload<br>protection is provided by the controller Up to 7200 V: 7BCLS, 7.2WKMSJ,<br>overload relays. 8ACLS, 8CLS<br>**----- End of picture text -----**<br>
Solenoids (coils)
**==> picture [537 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse type Sizing Fuse/volt recommendation<br>Up to 250 V: LPN-RK_SP, FRN-R (best)<br>Branch circuit Size at 125% or next size smaller<br>Up to 600 V: LPS-RK_SP, FRS-R, LPJ_SP, LP-CC, FNQ-R, TCF<br>Up to 32 V: MDL 9-30 A, FNM 20-30 A<br>Up to 125 V: MDA 25-30 A, FNM 12-15 A<br>Supplemental Size at 125% or next size larger<br>Up to 250 V: MDL 1/16-8 A, MDA 2/10-20 A, FNM 1/10-10 A, MDQ 1/100-7 A<br>Up to 500 V: FNQ 1/10-30 A<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
iii
**Introduction**
Transformers 600 V nominal or less (NEC 450.3)
**==> picture [537 x 331] intentionally omitted <==**
**----- Start of picture text -----**<br>
Thermal<br>overload Transformer Rated Optimum<br>Protection type protection impedance current protection* NEC maximums Fuse/volt recommendation<br>300% or next size smaller (see<br>Primary 125% or next<br>NEC 430.72(C) for control circuit<br>Primary < 2 amps size larger transformer maximum of 500%)<br>only (Note:<br>components on Primary<br>the secondary — — ≥ 2 amps 125% or next 167% or next size smaller<br>still need but < 9 size larger<br>overcurrent amps<br>protection)<br>Primary ≥ 125% or next<br>125% or next size larger**<br>9 amps size larger<br>Secondary<br>< 9 amps % of primary FLA (or next FLA<br>Without — (see A) size smaller)<br>Secondary A = 250%<br>≥ 9 amps Up to 250 V: LPN-RK_SP,<br>(see B) B = 250% FRN-R<br>C = 600% Up to 600 V: KRP-C_SP,<br>Secondary<br>LPJ_SP, LPS-RK_SP, FNQ-R,<br>< 9 amps (see C) Primary and D = 600% FRS-R, TCF<br>≤ 6% secondary E = 400%<br>Secondary fuses at 125%<br>Primary and ≥ 9 amps of primary and F = 400%<br>secondary (see D) secondary FLA % of secondary FLA<br>or next size<br>Secondary larger A = 167% or next size smaller<br>With < 9 amps<br>(see E) B = 125% or next size larger**<br>C = 167% or next size smaller<br>> 6% but<br>< 10% D = 125% or next size larger**<br>Secondary<br>≥ 9 amps E = 167% or next size smaller<br>(see F)<br>F = 125% or next size larger**<br>**----- End of picture text -----**<br>
* When sizing the primary fuse for optimum protection, verify the inrush current with the transformer manufacturer and review fuse time-current characteristics.
** When 125% of FLA corresponds to a standard rating, the next larger size is not permitted.
Eaton.com/bussmannseries
iv
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Introduction**
Transformers over 600 V nominal (NEC 450.3)
Supervised installations
**==> picture [537 x 249] intentionally omitted <==**
**----- Start of picture text -----**<br>
Transformer Secondary<br>Protection for impedance Primary Sizing volts Secondary sizing Fuse/volt recommendation<br>Code maximum of 250% Up to 250 V: LPN-RK_SP, FRN-R<br>or next standard size if<br>250% does not correspond Up to 600 V: LPS-RK_SP, LPJ-_SP, KRP-C_SP,<br>Primary only N/A to a standard rating N/A N/A FRS-R, FNQ-R, TCF<br>Note: Components on Up to 2.475 kV: 2NCLPT, 2CLPT<br>the secondary still need<br>overcurrent protection Up to 2.75 kV: 2CLE, 2HLE<br>At code maximum Up to 2750/5500 V: JCW<br>> 600 V<br>of 250%<br>≤ 6% At code maximum of 300% Up to 5.5 kV: 5HLE, 5CLE, 5HCL, 5BHCL,<br>At code maximum 5BHLE, 5AHLE, JCY, MV05, 5.5 ABWNA, 5.5<br>≤ 600 V of 250% AMWNA, 5.5 FFN<br>At code maximum 7 Up to 7.2 kV:.2 AMWNA, 7.2 TDLSJ, 7.2<br>> 600 V TFLSJ<br>of 225%<br>Up to 8.3 kV: 8HLE, 8CLE, 8BHLE, 8AHLE,<br>Primary and 8CLPT, 8NCLPT, 8HCL, 8.25 FFN<br>secondary Up to 15.5 kV: 15CLPT, 15NCLPT, 15CLE,<br>> 6% but 15HLE, 15BHLE, 15LHLE, 15HCL, 15BHCL,<br>< 10% At code maximum of 300% At code maximum MV155, 15.5 CAVH<br>≤ 600 V<br>of 250% Up to 17.5 kV: 17.5 CAV, 17.5 TDM<br>Up to 24 kV: 24 TDM, 24 TFM, 24 FFM<br>Up to 36 kV: 36 CAV, 36 TDQ, 36 TFQ<br>Up to 38 kV: 38CLPT, 38 CAV<br>**----- End of picture text -----**<br>
Unsupervised installations
**==> picture [537 x 225] intentionally omitted <==**
**----- Start of picture text -----**<br>
Transformer Secondary<br>impedance Primary Sizing volts Secondary sizing Fuse/volts recommendation<br>At code maximum of 250% or Up to 250 V: LPN-RK_SP, FRN-R<br>At code next standard size if 250% does<br>maximum of > 600 V not correspond to a standard Up to 600 V: LPS-RK_SP, LPJ-_SP, KRP-C_SP, FRS-R,<br>300% or next rating FNQ-R, TCF<br>≤ 6% standard size if<br>300% does not At code maximum of 125% or Up to 2475 V: 2NCLPT, 2CLPT<br>correspond to a ≤ 600 V next standard size if 125% does Up to 2.75 kV: 2CLE, 2HLE<br>standard rating not correspond to a standard<br>rating Up to 2750/5500 V: JCW<br>At code maximum of 225% or Up to 5.5 kV: 5HLE, 5CLE, 5HCL, 5BHCL, 5BHLE,<br>next standard size if 225% does 5AHLE, JCY, MV05, 5.5 ABWNA, 5.5 AMWNA, 5.5 FFN<br>> 600 V<br>not correspond to a standard Up to 7.2 kV: 7.2 AMWNA, 7.2 TDLSJ, 7.2 TFLSJ<br>rating<br>At code Up to 8.3 kV: 8HLE, 8CLE, 8BHLE, 8AHLE, 8CLPT,<br>maximum of 8NCLPT, 8HCL, 8.25 FFN<br>300% or next<br>> 6% but < 10% standard size if Up to 15.5 kV: 15CLPT, 15NCLPT, 15CLE, 15HLE,<br>300% does not At code maximum of 125% or 15BHLE, 15LHLE, 15HCL, 15BHCL, MV155, 15.5 CAVH<br>correspond to a ≤ 600 V next standard size if 125% does Up to 17.5 kV: 17.5 CAV, 17.5 TDM<br>standard rating not correspond to a standard<br>rating Up to 24 kV: 24 TDM, 24 TFM, 24 FFM<br>Up to 36 kV: 36 CAV, 36 TDQ, 36 TFQ<br>Up to 38 kV: 38CLPT, 38 CAV<br>**----- End of picture text -----**<br>
Solid state devices (diodes, SCRs, triacs, transistors)
**==> picture [538 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection type Sizing Fuse/volts recommendation<br>Up to 130 V: FWA<br>Up to 250 V: FWX<br>F, S, K, and 170M fuse families sized up to several sizes Up to 500 V: FWH<br>Short-circuit only<br>larger than full load RMS or DC rating of device Up to 600 V: FWC, KAC, KBC<br>Up to 700 V: FWP, 170M_, SPP<br>Up to 1000 V: FWJ, 170M_, SPJ<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
v
**BUSSMANN** SERIES ; y .s ’
## Do you know about the new 2017 NEC® SCCR requirements?
## **Finding out is easy.**
Eaton’s Bussmann™ series handbook Code changes affecting Short-Circuit Current Ratings based on the 2017 NEC will help you:
Know why SCCR is important.
Understand hazards associated with insufficient SCCR.
Know what specific NEC chapters, articles, parts and sections are involved.
Comply with Code requirements for marking and documenting SCCR.
If you’re designing, installing or inspecting equipment, download your copy at Eaton.com/nec2017sccr.
Or, check out our comprehensive SCCR resources at Eaton.com/bussmannseries/SCCR.
Follow us on social media to get the latest product and support information.
**Low voltage, branch circuit fuses — 1**
## Contents
|||||||Description<br>Fuse holder and block selection guide<br>Fuse reducers<br>Branch circuit fuse dimensions<br>Fuse class<br>Catalog symbol|Description<br>Fuse holder and block selection guide<br>Fuse reducers<br>Branch circuit fuse dimensions<br>Fuse class<br>Catalog symbol|Description<br>Fuse holder and block selection guide<br>Fuse reducers<br>Branch circuit fuse dimensions<br>Fuse class<br>Catalog symbol|Volts|Section<br>page<br>2<br>3-4|Low voltage,|branch circuit fuses|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||LP-CC|||5|||
|**The power of space**|||**The power of space**|||CC|FNQ-R<br>KTK-R||600 V|6<br>7|||
|Bussmann|Bussmann|Bussmann|BussmannTM|TMseries|||TCF<br>FCF||600 V|8-9<br>10|||
|CUBEFuseTM|TMdelivers the|||||CF|WCF||690 V|11|||
|smallest footprint compared to any Class|smallest footprint compared to any Class|smallest footprint compared to any Class|smallest footprint compared to any Class|smallest footprint compared to any Class|smallest footprint compared to any Class||TCFH_ Class CF holders||600 V|12-17|||
|J or RK fuse solution — requiring up to<br>70% less space when combined with its|J or RK fuse solution — requiring up to<br>70% less space when combined with its|||||G<br>J|SC<br>LPJ-_SP<br>LPJ-_SPI indicator||600/480 V<br>600 V|18<br>19|||
||||||||JKS|||20|||
||||||||NON||250 V||||
|||||||H(K)||||21|||
||||||||NOS||600 V||||
||||||||KRP-C_SP|||22|||
|ee:|ee:|ee:|||netQ rot|L<br>KRP-CL (225 to 600 A)<br>KTU<br>~~—~~||KRP-CL (225 to 600 A)|600 V|23|||
|“|ane|3|5|ood|MANN|KLU<br>~~oo~~||m—*rn0900||24|||
|er <br>oovacORLESS<br> rOORNG<br>retOrme||ah oe <br>i<br>: ee<br>ee<br>mess<br>!<br>TCFOORN?<br>wtQP||||RK1<br>LPN-RK_SP<br>250 V<br>24-26<br>LPN-RK_SPI indicator<br>LPS-RK_SP<br>600 V<br>LPS-RK_SPI indicator<br>KTN-R<br>250 V<br> ~~TS~~<br>~~re~~<br>~~<<~~<br>~~TT~~|||||||
|||||||||||27-28|||
||||||||KTS-R||600 V||||
||||||||FRN-R||||||
||||||||||250 V||||
||||||||FRN-R_ID indicator||||||
|||||||RK5||||29-30|||
||||||||FRS-R||||||
||||||||||600 V||||
||||||||FRS-R_ID indicator||||||
||||||||JJN||300 V||||
|||||||T||||31-32|||
||||||||JJS||600 V||||
||||||||SL, TL and W|||33|||
||||||||P, S, T and TC|||34|||
|||||||Plug fuses|MB Edison base circuit breakers||125 V|35|||
||||||||SA fuse adapters||||||
||||||||Box cover units|||36|||
## **The power of space**
The revolutionary Bussmann[TM] series Low-Peak[TM] CUBEFuse[TM] delivers the
For conductor protection, see cable limiters in Section 2, page 3.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-1
**1 — Low voltage, branch circuit fuses**
## Fuse holder and block selection guide
Catalog pages for the blocks and holders are denoted parenthetically "()" next to their catalog symbol.
**==> picture [536 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse class Catalog symbol Blocks DIN-Rail holders Panel mount holders In-line holders<br>**----- End of picture text -----**<br>
|Fuse class|Catalog symbol<br>Blocks<br>DIN-Rail holders<br>Panel mount holders<br>In-line holders|
|---|---|
|CC|FNQ-R<br>KTK-R<br>LP-CC<br>BCM (8-6)<br>3743 (8-14)<br>4421 (8-14)<br>4515 (8-14)<br>CHCC (8-8)<br>OPM-1038 (8-12)<br>OPM-NG (8-13)<br>CCP2-CC†††(11-2)<br>HPF-RR (8-43)<br>HPS-RR (8-45)<br>CCPLP†††(30 A) (11-32)<br>HEY (8-53)<br>HEZ (8-52)|
|CF|FCF<br>TCF<br>WCF††<br>TCFH (1-13)<br>TCFHNW (1-13)<br>(Panel and DIN-Rail mount)<br>CCP2-CF†††(11-6)<br>CCP2B†††(11-29)<br>—<br>—|
|G|SC<br>BG (8-15)<br>G (8-15)<br>—<br>CCPLP†††(20 A) (11-32)<br>HPG-EE (15 A) (8-44)<br>HPS-EE (15 A) (8-45)<br>HPS-FF (30 A) (8-45)<br>HPS-JJ (20 A) (8-45)<br>HEC (30 A) (8-49)<br>HEG (15 A) (8-49)<br>HEH (20 A) (8-49)<br>HEJ (60 A) (8-49)|
|H(K) 250 V|NON (250 V)<br>HM25_ (8-19)<br>HM25060_MW* (8-24)<br>—<br>—<br>—|
|H(K) 600 V|NOS (600 V)<br>HM60_ (8-19)<br>HM60030_MW* (8-24)<br>—<br>—<br>—|
|J|LPJ<br>JKS<br>JM60_ (8-31)<br>JM60_MW* (8-33)<br>JP60030 (8-30)<br>CH_J (8-28)<br>JT(N) (8-29)<br>—<br>—|
|L|KRP-C<br>KRP-CL<br>KLU<br>KTU<br>51215**<br>51235**<br>—<br>—<br>—|
|RK1 250 V|LPN-RK<br>KTN-R<br>RM25_ (8-21)<br>RM25_MW* (8-26)<br>—<br>—<br>—|
|RK1 600 V|LPS-RK<br>KTS-R<br>RM60_ (8-21)<br>RM60_MW* (8-26)<br>—<br>—<br>—|
|RK5 250 V|FRN-R<br>RM25_ (8-21)<br>RM25_MW* (8-26)<br>—<br>—<br>—|
|RK5 600 V|FRS-R<br>RM60_ (8-21)<br>RM60_MW* (8-26)<br>—<br>—<br>—|
|T 300 V|JJN<br>T300 (8-35)<br>—<br>—<br>—<br>JJS<br>T600 (8-37)<br>JJN/JJS<br>BH-0_, BH-1_, BH-3_† (8-39)|
|T 600 V||
|T up to 600 V||
|Plug fuses|P, T, TC, TL, W Edison base<br>Box cover units (1-30)<br>—<br>—<br>—|
||S, SL rejection base<br>SA adapters (1-29)<br>—<br>—<br>—|
- Power distribution fuse blocks.
- ** Up to 800 A, contact customer satisfaction at 855-287-7626 for more information.
- Various blade bolt-on up to 700 A, see data sheets for limitations.
- †† WCF (wind CUBEFuse) is rated to 690 V and is not a UL Listed Class CF fuse and can only be applied in the TCFHNW holder. ††† UL 98 Listed disconnect switch, available in 1-, 2- and 3-pole versions.
## 250 V Class R fuse reducers
## 600 V Class R fuse reducers
**==> picture [537 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
Equipment fuse clip Desired fuse (case) Equipment fuse clip Desired fuse (case)<br>amps amp size Catalog no. (pairs) amps amp size Catalog no. (pairs)<br>**----- End of picture text -----**<br>
|Equipment fuse clip<br>amps|Desired fuse (case)<br>amp size<br>Catalog no. (pairs)|Equipment fuse clip<br>amps|Desired fuse (case)<br>amp size<br>Catalog no. (pairs)|
|---|---|---|---|
|60|30<br>NO.263-R<br>30<br>NO.213-R<br>60<br>NO.216-R<br>60<br>NO.226-R<br>100<br>NO.2621-R<br>100<br>NO.2641-R<br>200<br>NO.242-R<br>100<br>NO.2661-R<br>200<br>NO.2662-R<br>400<br>NO.2664-R*|60|30<br>NO.663-R|
|100||100|30<br>NO.216-R|
||||60<br>NO.616-R|
|200||200|60<br>NO.626-R|
||||100<br>NO.2621-R|
|400||400|100<br>NO.2641-R|
||||200<br>NO.642-R|
|600||600|100<br>NO.2661-R|
||||200<br>NO.2662-R|
||||400<br>NO.2664-R*|
* Single reducer only (pair not required).
- Single reducer only (pair not required).
Eaton.com/bussmannseries
1-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
## Branch circuit fuse dimensions
Class CC — in (mm)
LP-CC, FNQ-R, KTK-R and LP-CC
**==> picture [263 x 178] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>B<br>Amp range A B<br>Up to 30 1.5 (38) 0.41 (10)<br>Class CF — in (mm)<br>B<br>C<br>A<br>Up to 100 A<br>**----- End of picture text -----**<br>
**==> picture [252 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>A<br>Up to 100 A<br>E D<br>B C<br>110 to 400 A<br>A<br>D<br>E<br>**----- End of picture text -----**<br>
**==> picture [263 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse<br>amps A B C D E<br>**----- End of picture text -----**<br>
|Fuse<br>amps<br>A<br>B|C|D|E|
|---|---|---|---|
|1-15<br>1.88 (48)<br>0.75 (19)<br>17-1/2*<br>20<br>25-30|1.0 (25)|0.23 (6)|0.67 (17)|
|||0.27 (7)||
|||0.31 (8)||
|35-40<br>2.13 (54)<br>1.0 (25)<br>45-50<br>60<br>70<br>3.01 (76)<br>80-90<br>100|1.13 (29)|0.36 (9)||
|||0.44 (11)||
||1.26 (32)|0.49 (12)|0.64 (16)|
|||0.57 (14)||
|110<br>3.62 (92)<br>2.9 (74)<br>125<br>150<br>175<br>200<br>225|1.34 (34)|1.02 (26)|0.51 (13)|
||||0.51 (13)|
||||0.51 (13)|
||||0.57 (14.5)|
||||0.57 (14.5)|
||||0.63 (16)|
|250<br>4.25 (108)<br>3.46 (88)<br>300<br>350<br>400|1.69 (43)|1.47 (36)|0.73 (18.5)|
||||0.79 (20)|
||||0.86 (21.5)|
||||0.86 (21.5)|
Class J — in (mm)
LPJ and JKS
||~~A~~<br>B<br>E<br>1 to 60A|||A|A|A||||
|---|---|---|---|---|---|---|---|---|---|
|||||||||||
|||||C<br>D||||||
|||||||||||
|||||||||||
|||||H<br>70 to 600A||||||
|Amp<br>range|A<br>B<br>C||D<br>E||||F<br>G<br>H<br>I|||
|1-30|2.25<br>(57)<br>0.81<br>(21)<br>—||—<br>0.5<br>(13)||||—<br>—<br>—<br>—|||
|35-60|2.38<br>(60)<br>1.06<br>(27)<br>—||—<br>0.63<br>(16)||||—<br>—<br>—<br>—|||
|70-100|4.63<br>(118)<br>1.13<br>(29)<br>3.63<br>(92)||2.63<br>(67)<br>1.0<br>(25)<br>0.75<br>(29)<br>0.13<br>(3)<br>0.41<br>(10)<br>0.28<br>(7)|||||||
|110-<br>200|5.75<br>(146)<br>1.63<br>(41)<br>4.38<br>(111)||3.0<br>(76)<br>1.38<br>(35)<br>1.13<br>(29)<br>0.19<br>(5)<br>0.38<br>(10)<br>0.28<br>(7)|||||||
|225-<br>400|7.12<br>(181)<br>2.11<br>(54)<br>5.25<br>(133)||3.26<br>(83)<br>1.87<br>(48)<br>1.62<br>(41)<br>0.25<br>(6)<br>0.56<br>(14)<br>0.4<br>(10)|||||||
|450-<br>600|8.0<br>(203)<br>2.6<br>(66)<br>6.0<br>(152)||3.31<br>(84)<br>2.12<br>(54)<br>2.0<br>(51)<br>0.53<br>(14)<br>0.72<br>(18)<br>0.53<br>(14)|||||||
Class RK1 and RK5 — in (mm)
FRN-R, KTN-R, LPN-RK (250 V) and FRS-R, KTS-R, LPS-RK (600 V)
**==> picture [258 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
A A<br>B B<br>Up to 60 A 70 to 600 A<br>**----- End of picture text -----**<br>
Basic dimensions are same as Class H, one-time (NON and NOS) fuses. Note: relating to dimensional compatibility these fuses can replace existing Class H, RK1 and RK5 fuses.
|Amp range|250 V fuses<br>600 V fuses|
|---|---|
||A<br>B<br>A<br>B|
|Up to 30|2 (51)<br>0.56 (14)<br>5.0 (127)<br>0.81 (21)|
|35-60|3 (76)<br>0.81 (21)<br>5.5 (140)<br>1.06 (27)|
|RK5 FRN-R, FRS-R, — RK1 KTN-R, KTS-R||
|70-100<br>5.88 (149)<br>1.06 (27)<br>7.88 (200)<br>1.34 (34)||
|110-200<br>7.13 (181)<br>1.56 (40)<br>9.63 (245)<br>1.84 (47)||
|225-400<br>8.63 (219)<br>2.38 (61)<br>11.63 (295)<br>2.59 (66)||
|450-600<br>10.38 (264)<br>2.88 (73)<br>13.38 (340)<br>3.13 (80)||
|RK1 LPN-RK, LPS-RK||
|70-100<br>5.88 (149)<br>1.16 (30)<br>7.88 (200)<br>1.16 (30)||
|110-200<br>7.13 (181)<br>1.66 (42)<br>9.63 (245)<br>1.66 (42)||
|225-400<br>8.63 (219)<br>2.38 (61)<br>11.63 (295)<br>2.38 (61)||
|450-600<br>10.38 (264)<br>2.88 (73)<br>13.38 (340)<br>2.88 (73)||
* Time-delay (TCF) only.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-3
**1 — Low voltage, branch circuit fuses**
Class T — in (mm)
JJN (300 V) and JJS (600 V)
**==> picture [253 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>A A C<br>D<br>B B 1.0 (25) B<br>JJN up to 60 A JJS 35 to 60 A JJN 70 to 1200 A<br>JJS up to 30 A JJS 70 to 800 A<br>**----- End of picture text -----**<br>
**==> picture [537 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
300 V JJN 600 V JJS<br>Amp range A B C D Amp range A B C D<br>**----- End of picture text -----**<br>
|300 V JJN<br>Amp range<br>A<br>B<br>C<br>D|600 V JJS<br>Amp range<br>A<br>B<br>C<br>D|
|---|---|
|Up to 30<br>0.88 (22)<br>0.41 (10)<br>—<br>—<br>35-60<br>0.88 (22)<br>0.56 (14)<br>—<br>—<br>70-100<br>2.16 (55)<br>0.75 (19)<br>1.56 (40)<br>0.84 (21)<br>110-200<br>2.44 (62)<br>0.88 (22)<br>1.69 (43)<br>0.84 (21)<br>225-400<br>2.75 (70)<br>1.00 (25)<br>1.84 (47)<br>0.86 (22)<br>450-600<br>3.06 (78)<br>1.25 (32)<br>2.03 (52)<br>0.88 (22)<br>601-800<br>3.38 (86)<br>1.75 (45)<br>2.22 (56)<br>0.89 (23)<br>801-1200<br>4.00 (102)<br>2.00 (51)<br>2.53 (64)<br>1.08 (27)|Up to 30<br>1.50 (38)<br>0.56 (14)<br>—<br>—|
||35-60<br>1.56 (40)<br>0.81 (21)<br>—<br>—|
||70-100<br>2.95 (75)<br>0.75 (19)<br>2.36 (60)<br>1.64 (42)|
||110-200<br>3.25 (83)<br>0.88 (22)<br>2.50 (64)<br>1.66 (42)|
||225-400<br>3.63 (92)<br>1.00 (25)<br>2.72 (69)<br>1.73 (44)|
||450-600<br>3.98 (101)<br>1.25 (32)<br>2.96 (75)<br>1.78 (45)|
||601-800<br>4.33 (110)<br>1.75 (45)<br>3.17 (81)<br>1.88 (48)|
|||
## Branch circuit fuse dimensions
Class L — in (mm)
KLU, KRP-C_SP, KRP-CL, KTU
|||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||All slots and holes|||||||||||J3|||J2<br>J4||||J3||||||D<br>J2<br>J4<br>4500<br>to<br>6000 A||||||~~F~~<br>G|
|||||||||||||||||||||||||||||||||
|||||||||||||J1|||||||J1|||||||||||||
|||||||||||||||||||||||||||||||||
|||||||||||||I||||||||||||||||||||
|||||||||||||||||||||||||||||||||
|||A||||||||||||||||||||||||||||||
|||||A<br>C1||||||||||||||||||||||||||||
||||||1|||||||||||||||||||||||||||
||||||||||C|2|||20<br>t<br>30|||||||||||||||||||
|||||||601<br>||to<br>800 A|||801<br>to|2000 A||20<br>t<br>30|01<br>o<br>00 A||||3500<br>to<br>4000 A||||||4500<br>to<br>6000 A|||||||
|||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||
||||||||||||||||||||||||||||||||~~B~~|
|||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||
|Amp<br>range<br>A||||||B||C1||||C2|||D<br>||||F|||G|||I<br>J1||||||J2<br>J3<br>J4|
|601-800<br>8.63 (219)|||2.4 (61)|||||6.75 (172)<br>||||5.75 (146)<br>3.|||75 (95)<br>2.00 (51)<br>0.38 (10)||||||||||0.63 (16)<br>—||||||—<br>—<br>—|
|801-1200<br>10.75 (273)<br>2.4 (61)||||||||6.75 (172)<br>||||5.75 (146)<br>3.|||75 (95)<br>2.00 (51)<br>0.38 (10)||||||||||0.63 (16)<br>—||||||—|
|1350-1600<br>10.75 (273)<br>3.0 (76)||||||||6.75 (172)<br>||||5.75 (146)<br>3.|||75 (95)<br>2.38 (60)<br>0.44 (11)||||||||||0.63 (16)<br>—||||||—<br>—<br>—|
|1800-2000<br>10.75 (273)<br>3.5 (89)||||||||6.75 (172)<br>||||5.75 (146)<br>3.|||75 (95)<br>2.75 (70)<br>0.5 (13)||||||||||0.63 (16)<br>—||||||—<br>—<br>—|
|2001-2500<br>10.75 (273)<br>4.8 (122)||||||||6.75 (172)<br>||||5.75 (146)<br>3.|||75 (95)<br>3.50 (89)<br>0.75 (19)||||||||||0.63 (16)<br>1.75 (45)||||||1.38 (35)<br>0.88 (22)<br>0.81 (21)|
|3000<br>10.75 (273)<br>5.0 (127)||||||||6.75 (172)<br>||||5.75 (146)<br>3.|||75 (95)<br>4.00 (102)<br>0.75 (19)||||||||||0.63 (16)<br>1.75 (45)||||||1.38 (35)<br>0.88 (22)<br>0.81 (21)|
|3500-4000<br>10.75 (273)<br>5.75 (146)<br>6.75 (172)<br>||||||||||||5.75 (146)<br>3.|||75 (95)<br>4.75 (121)<br>0.75 (19)||||||||||0.63 (16)<br>1.75 (45)||||||1.38 (35)<br>1.63 (41)<br>0.88 (22)|
|4500-5000<br>10.75 (273)<br>6.25 (159)<br>6.75 (172)<br>||||||||||||5.75 (146)<br>3.|||75 (95)<br>5.25 (133)<br>1.0 (25)||||||||||0.63 (16)<br>1.75 (45)||||||1.38 (35)<br>1.63 (41)<br>0.88 (22)|
|6000<br>10.75 (273)<br>7.13 (181)<br>6.75 (172)<br>||||||||||||5.75 (146)<br>3.|||75 (95)<br>5.75 (146)<br>1.0 (25)||||||||||0.63 (16)<br>1.75 (45)||||||1.38 (35)<br>1.63 (41)<br>0.88 (22)|
Note: KRP-CL (225-600 A) fuses have same dimensions as 601-800 A case size KTU (200-600 A) have same dimensions, except tube 3" length x 2" diameter (76 x 51 mm); terminal 1-5/8" width x 1-1/4" thick (41 x 32 mm).
Eaton.com/bussmannseries
1-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
Time-current characteristics — average melt
## LP-CC Class CC Low-Peak™ time-delay, rejection-type fuses
Amp rating 200 100 “UAW —= FEAL WANA WEE **2011/65/EU** osaa 10 AWAAA AY es COCA TAA AAA PoeACA ce AAR FAVE 1 IEIU | 0 ee au \ene 0.1 TEA ecnLAestatetn ES A VATA A Hk VAAN 0.01 EEE WAAL Current in amps
Time-delay, current-limiting, rejection-type fuse — 12 seconds (minimum) at 200% rated amps. For dimensions, see page 1-3.
## Ratings
- Volts
- 600 Vac (or less)
- 300 Vdc (1/2 to 2-8/10 A and 20-30 A)
- 150 Vdc (3-15 A)
- Amps 1/2-30 A
- IR
- 200 kA RMS Sym.
- 20 kA DC
## Agency information
- UL Listed Std 248-4, Class CC, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787, RoHS compliant (20-30 A)*, CE
- Contact factory for RoHS compliance on other ratings.
## Features
- Class CC rejection feature, with appropriate fuse block, prevents inserting lesser-rated supplementary fuses
- Time-delay coupled with Class CC current-limiting response provides close sizing on small motor and relay circuits, and maximum component short-circuit current rating protection
- 200 kA interrupting rating provides high ratings for control circuit locations
- Inventory consolidation of 13/32" x 1-1/2" supplemental fuses reduces SKU investment and minimizes potential for misapplying fuse
## Current limitation curves
- Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit
## Typical applications
- Branch circuit protection
- Specialized circuits
- Industrial controls and panels
- Isolated, in-line fuse holder
|Catalog no. (amps)<br>LP-CC-1/2<br>LP-CC-6/10<br>LP-CC-8/10<br>LP-CC-1<br>LP-CC-1-1/8|LP-CC-1-8 /10<br>LP-CC-2<br>LP-CC-2-1/4<br>LP-CC-2-1/2<br>LP-CC-2-8/10|LP-CC-4-1/2<br>LP-CC-5<br>LP-CC-5-6/10<br>LP-CC-6<br>LP-CC-6-1/4|LP-CC-10<br>LP-CC-12<br>LP-CC-15<br>LP-CC-20<br>LP-CC-25|
|---|---|---|---|
|LP-CC-1-1/4|LP-CC-3|LP-CC-7|LP-CC-30|
|LP-CC-1-4/10|LP-CC-3-2/10|LP-CC-7-1/2||
|LP-CC-1-1/2|LP-CC-3-1/2|LP-CC-8||
|LP-CC-1-6/10|LP-CC-4|LP-CC-9||
**==> picture [261 x 188] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>30<br>25<br>20<br>15<br>veer EEE EII -C e r 2-8/10<br>1-1/4<br>00 ee<br>~Teerite cin cin<br>A<br>oe<br>eL-LUTI TTI EET VI<br>cee ees 2 8 Fe EEE EE |<br>Prospective Short-Circuit Current (RMS Sym. Amps)<br>Amp Rating<br>Instantaneous Peak Let-Through Current In Amps<br>**----- End of picture text -----**<br>
Recommended holders and blocks for Class CC fuses, see page 1-2.
Data sheet no. 1023
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-5
**1 — Low voltage, branch circuit fuses** TOR
## FNQ-R Class CC Limitron™ time-delay, rejection-type fuse
Time-current characteristics — average melt
**==> picture [533 x 446] intentionally omitted <==**
**----- Start of picture text -----**<br>
Amp rating<br>Time-delay, branch circuit, rejection-type fuse. For superior electrical 100<br>protection, Eaton recommends upgrading FNQ-R fuse applications<br>to Bussmann series Low-Peak LP-CC fuses, see page 1-5. For<br>dimensions, see page 1-3.<br>Ratings<br>ni<br> • Volts<br>2011/65/EU<br> • 600 Vac (or less) ° POCA Tp<br> • 300 Vdc (15-20 A)<br>= 10 NV<br> • 32 Vdc (self certified)<br> • Amps 1/4-30 A<br> • IR • 200 kA RMS Sym. HTM APTN A EE<br> • 20 kA DC (15 and 20 A only)<br>CATA conc<br>Agency information<br>1<br> • UL Listed, Std 248-4, Class CC, Guide JDDZ, File E4273,<br>CSA Certified, Class 1422-01, File 53787, RoHS compliant, CE<br>Features<br>HPT ETM YEN<br> • Class CC rejection feature, with appropriate fuse block, prevents<br>inserting lesser-rated supplementary fuses<br>[ONT BTN<br> • Time-delay compatible with inrush characteristic of small control<br>transformers<br>0.1<br> • Current limitation at Class CC levels provides maximum<br>component short-circuit current rating protection<br> • 200 kA interrupting rating provides high ratings for control circuit<br>locations<br>Ch VICENTE NCE<br>Typical applications<br> • Line protection, small control transformers COTaN<br> • Industrial controls and panels 0.01 LEAT<br> • Isolated, in-line fuse holders QP N.<br>Current in amps<br>1/2 1 3 5 7-1/2<br>Time in seconds<br>0.08 1 10 100 200 300 400 500<br>**----- End of picture text -----**<br>
|Catalog no. (amps)<br>~~eee~~|Catalog no. (amps)<br>~~eee~~|Catalog no. (amps)<br>~~eee~~|Catalog no. (amps)<br>~~eee~~|
|---|---|---|---|
|FNQ-R-1/4|FNQ-R-1-3/10|FNQ-R-3-2/10|FNQ-R-8|
|FNQ-R-3/10|FNQ-R-1-4/10|FNQ-R-3-1/2|FNQ-R-9|
|FNQ-R-4/10|FNQ-R-1-1/2|FNQ-R-4|FNQ-R-10|
|FNQ-R-1/2|FNQ-R-1-6/10|FNQ-R-4-1/2|FNQ-R-12|
|FNQ-R-6/10|FNQ-R-1-8/10|FNQ-R-5|FNQ-R-15|
|FNQ-R-3/4|FNQ-R-2|FNQ-R-5-6/10|FNQ-R-17-1/2|
|FNQ-R-8/10|FNQ-R-2-1/4|FNQ-R-6|FNQ-R-20|
|FNQ-R-1|FNQ-R-2-1/2|FNQ-R-6-1/4|FNQ-R-25|
|FNQ-R-1-1/8|FNQ-R-2-8/10|FNQ-R-7|FNQ-R-30|
|FNQ-R-1-1/4|FNQ-R-3|FNQ-R-7-1/2||
Recommended holders and blocks for Class CC fuses, see page 1-2.
Data sheet no. 1014
Eaton.com/bussmannseries
1-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
## TBST
## KTK-R Class CC Limitron™ fast-acting, rejection-type fuse
Time-current characteristics — average melt
Fast-acting, branch circuit, rejection-type fuse. For superior electrical protection, Eaton recommends upgrading KTK-R fuse applications to Bussmann series Low-Peak LP-CC fuses, see page 1-5. For dimensions, see page 1-3.
## Ratings
- Volts 600 Vac (or less)
**==> picture [23 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- Amps 1/10-30 A
- IR 200 kA RMS Sym.
Agency information
- UL Listed, Std 248-4, Class CC, Guide JDDZ, File E4273, CSA Certified, File 53787, Class 1422-02, RoHS compliant, CE
Features
- Class CC rejection feature, with appropriate fuse block, prevents inserting lesser-rated supplementary fuses
- Current limitation at Class CC levels provides maximum component short-circuit current protection
- 200 kA interrupting rating provides high ratings for control circuit locations
Typical applications
- Specialized circuits
> • Industrial controls and panels
|• Specialized circuits<br>• Industrial controls and panels|• Specialized circuits<br>• Industrial controls and panels|• Specialized circuits<br>• Industrial controls and panels|• Specialized circuits<br>• Industrial controls and panels|• Specialized circuits<br>• Industrial controls and panels||
|---|---|---|---|---|---|
|• Isolated, in-line fuse holders (street lighting)<br>Catalog no. (amps)<br>KTK-R-1/10<br>KTK-R-6/10<br>KTK-R-3-1/2<br>KTK-R-10<br>KTK-R-1/8<br>KTK-R-3/4<br>KTK-R-4<br>KTK-R-12<br>~~a~~|||||AEA<br> VV|
|KTK-R-2/10|KTK-R-1|KTK-R-5|KTK-R-15|||
|KTK-R-1/4|KTK-R-1-1/2|KTK-R-6|KTK-R-20|||
|KTK-R-3/10|KTK-R-2|KTK-R-7|KTK-R-25|||
|KTK-R-4/10|KTK-R-2-1/2|KTK-R-8|KTK-R-30|||
|KTK-R-1/2|KTK-R-3|KTK-R-9||||
Recommended holders and blocks for Class CC fuses, see page 1-2.
Data sheet no. 1015
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-7
**1 — Low voltage, branch circuit fuses**
TCF Class CF Low-Peak time-delay CUBEFuse™
## Features
- Smallest installed footprint of any UL Class CC, J, or R fuse solution
- Easy application using CUBEFuse holders (TCFH_N), UL 98 Compact Circuit Protector (CCP2) switches and Compact Circuit Protector Base (CCP2B up to 100 A). See data sheet 9007 for details on the CUBEFuse holder, 10801 for details on the CCP2-_ CF switch and 1161 for the CCP2B.
- Holders and switches have an amp rating rejection feature to help prevent overfusing; 30, 60 and 100 A switches and holders will hold any CUBEFuse up to its rating, 200 and 400 A switches and 200, 225 and 400 A holders will hold any CUBEFuse 110 A and above up to its rating
> • The indicating version features local easyID™ open fuse technology for faster troubleshooting and reduced downtime
> • Faster response to damaging faults helps reduce destructive thermal and magnetic forces
The Bussmann series Low-Peak CUBEFuse is a finger-safe UL Class CF current-limiting, dual-element, time-delay branch circuit fuse and fuse holder system; 10 seconds minimum operating time at 500% rated amps. With Class J electrical performance, teh time-delay CUBEFuse is available in indicating and non-indicating versions, this finger-safe fuse has a very compact, space-saving size and is easily applied using the CUBEFuse holder (TCFH_N), UL 98 Compact Circuit Protector switch (CCP2-_CF) or Compact Circuit Protector Base (CCP2B up to 100 A) used in the Quik-Spec™ Coordination Panelboard). For dimensions, see page 1-3.
## Ratings
- Volts
- 600 Vac
- True dual-element fuse construction with a minimum 10 seconds time-delay at 500% of rating
- Long time-delay minimizes nuisance openings caused by temporary overloads and transient surges
- Up to 300 kA interrupting rating safely interrupts virtually any fault
- Robust cycling and inrush current withstand
- Low let-through currents under fault conditions
- Provides Type 2 “No Damage” protection for IEC motor starters when properly sized
- Easy selective coordination with any other Bussmann series Low-Peak Class CC, J, L or RK1 fuse with simple 2:1 amp ratio between upstream and downstream fuses
- 300 Vdc
- Amps
- 6-400 A (indicating)
- Finger-safe status depends on final, installed application, and will require using accessory shrouds for 110 to 400 A ratings.
## Typical applications
- 1-400 A (non-indicating)
- Interrupting rating
- 300 kA RMS Sym. (Up to 100 A UL)
- 200 kA RMS Sym. (110 to 400 A UL)
- 200 kA RMS Sym. (Up to 100 A CSA)
- Electrical panelboards
- Machinery disconnects
- Industrial controls and panels
- Required finger-safe systems
- 100 kA DC (Up to 400 A UL and up to 100 A CSA)
## Watts loss at rated current
|Fuse amps|Watts|
|---|---|
|30|3.99|
|60|6.23|
|100|9.51|
|200|18.6|
|225|17.6|
|400|35.2|
## Agency information
- UL Listed Class CF fuse: Guide JDDZ, File E4273 (up to 400 A)
- CSA[®] Certified fuse: Class 1422-02, File 053787_C_000 (up to 100 A)
- CE (100 A and below)
- RoHS compliant
Operating and storage temperature range
- -40 to 80°C (-40°F to 176°F)
|Catalog numbers (amps)|Catalog numbers (amps)|||
|---|---|---|---|
|Indicating CUBEFuse||||
|TCF6|TCF35|TCF90|TCF225|
|TCF10|TCF40|TCF100|TCF250|
|TCF15|TCF45|TCF110|TCF300|
|TCF17-1/2|TCF50|TCF125|TCF350|
|TCF20|TCF60|TCF150|TCF400|
|TCF25|TCF70|TCF175||
|TCF30|TCF80|TCF200||
|Non-Indicating CUBEFuse||||
|TCF1RN|TCF25RN|TCF70RN|TCF175RN|
|TCF3RN|TCF30RN|TCF80RN|TCF200RN|
|TCF6RN|TCF35RN|TCF90RN|TCF225RN|
|TCF10RN|TCF40RN|TCF100RN|TCF250RN|
|TCF15RN|TCF45RN|TCF110RN|TCF300RN|
|TCF17-1/2RN|TCF50RN|TCF125RN|TCF350RN|
|TCF20RN|TCF60RN|TCF150RN|TCF400RN|
Recommended holders for Class CF fuses, see page 1-12.
## Data sheet no. 9000 (fuses) and 9007 (holders)
Eaton.com/bussmannseries
1-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
Up to 100 A time-current characteristics — average melt
110 to 400 A time-current characteristics — average melt
Up to 100 A current let-through curves
**==> picture [255 x 354] intentionally omitted <==**
**----- Start of picture text -----**<br>
1000 Ss==eee<br>RSee SO|SVA<br>ATONE OTT<br>100<br>——ETN AIET<br>bePAWNIERIEEEE<br>10 ee ENTeeTTT<br>_——— ee ee ee ee ee<br>—| es—| oe| ee| oeIY serrr VvTVynsetySee |: sr +,srtserirteys<br>eS a aWY<br>a eeeel ee<br>1 J_{__}tL _{|_}_}jAE{| [f{}__\\{\__j}\_{|_}_j_] VAAL{| ft<br>ee<br>es ee ee<br>OOOO |<br>0.1 > FTAA<br>SS _ SS SS ee<br>ee es ee a eS<br>a OM<br>a a V<br>0.01 PT [ELE] AAA EE<br>CURRENT IN AMPS<br>110 to 400 A current let-through curves<br>110A 200A 225A 250A 400A<br>TIME IN SECONDS<br>100 1,000 10,000<br>**----- End of picture text -----**<br>
**==> picture [373 x 188] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>100,000 eee eee cer<br>A eo 400A<br>250A<br>225A<br>200A<br>110A<br>10,000<br>ee40A60A | | | a4 IereEET<br>ea FE a<br>oa aie e e mas eee<br> toeee Paa elle)<br>TTIL 1 , 000 Cea——_— ee —_— = — —<br>A Zo<br>TTT ff<br>100<br>nh PL ETTUIE TERT FETE<br>gg8 PROSPECTIVE SHORT CIRCUIT CURRENT<br>g gs 8 SYMMETRICAL RMS AMPS<br>INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS<br>100 1,000 10,000 100,000<br>**----- End of picture text -----**<br>
Data sheet no. 9000 (fuses) and 9007 (holders)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-9
## **1 — Low voltage, branch circuit fuses**
## FCF Class CF fast-acting CUBEFuse
Finger-safe, non-indicating, fast-acting CUBEFuse for UPS and critical applications with a 4 minute maximum clearing time at 200%, rated current for 1 to 30 A fuse, 6 minute maximum clearing time at 200%, rated current for 35 to 60 A fuse. For dimensions, see page 1-3.
## Ratings
- Volts 600 Vac/dc (or less)
- Amps 1-100 A
**==> picture [77 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>aoe “feet i<br>**----- End of picture text -----**<br>
- IR
- 300 kA RMS Sym. (UL up to 60 A)
- 200 kA RMS Sym. (CSA all ratings and UL 70 to 100 A)
- 50 kA DC
## Agency information
- UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422- 02, File 53787, RoHS compliant, CE
## Features
- The world's first finger-safe power fast-acting fuse system
- Smallest installed footprint of any class fuse including Class CC, J, and RK
- Class CF meets Class J fast-acting electrical performance requirements
- True fast-acting for faster response to damaging faults to help reduce destructive thermal and magnetic forces
- High interrupting rating to safely interrupt faults up to 300 kA
- No venting of arc or molten metal and gases during opening
- Low let-through currents under fault conditions
|Catalog no. (amps)||||
|---|---|---|---|
|FCF1RN|FCF20RN|FCF45RN|FCF90RN|
|FCF3RN|FCF25RN|FCF50RN|FCF100RN|
|FCF6RN<br>FCF10RN<br>FCF15RN|FCF30RN<br>FCF35RN<br>FCF40RN|FCF60RN<br>FCF70RN<br>FCF80RN||
Recommended holders for Class CF fuses, see page 1-12.
Time-current characteristics — average melt
**==> picture [262 x 555] intentionally omitted <==**
**----- Start of picture text -----**<br>
Amp rating<br>1000<br>PEATE AW<br>100<br>a ae ee a ee<br>iN<br>10<br>ae aee<br>PTELA WA<br>1<br>TT A<br>0.1<br>eee ees eee See Ne et ns<br>SAAN<br>NN AAA oy<br>0.01 COAWINCAAT<br>Current in amps<br>Current limitation curves<br>B<br>100,000<br>100A<br>10,000 60A<br>30A<br>15A<br>1000<br>100A eeeeee<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>1 3 6 10 15 20 30 40 50 60 100<br>Time in seconds<br>1 10 100 1000 10,000<br>Instantaneous peak let-through current in amps<br>100 1000 10,000 100,000 300,000<br>**----- End of picture text -----**<br>
## Current limitation curves
Data sheet no. 2147 (fuses) and 9007 (holders)
Eaton.com/bussmannseries
1-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
## WCF fast-acting 690 V wind power CUBEFuse
Finger-safe, non-indicating, fast-acting CUBEFuse for wind power generation systems with a maximum clearing time at 200% rated current: 4 minutes for 1 to 30 amp fuses, 6 minutes for 35 to 60 amp fuses, 8 minutes for 70 to 100 amp fuses. For dimensions, see page 1-3.
## Ratings
**==> picture [83 x 40] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>e =;<br>**----- End of picture text -----**<br>
- Volts 690 Vac
- Amps 1-100 A
- IR
- 50 kA AC (1-60 A)
- 30 kA AC (70-100 A)
## Agency information
- UL Recognized, Guide JFHR2, File E56412, cURus Component Certified C22.2, RoHS compliant, CE
## Features
- Maximize uptime and reliability using fuses designed and listed to UL 248-1
- Minimize chances of equipment failure and personnel injury when using full range fuses having the industry's fastest response time to low-magnitude faults
- Maximize return on investment with fuses proven to withstand harsh temperatures
- Minimize design time, operating outage time and replacement cost with fuses qualified in excessively changing environmental conditions
- Simplify compatibility with readily available industry standard holders
- Temperature derating — Designed to maximize rated capacity in elevated environmental temperatures
- Overload protection — Proven to clear faults faster than the UL requirement
- Power loss — Minimal energy consumption leading to increased efficiency
## Typical application
- Protecting wind system transformers, pitch and speed controls, and turbine HVAC and lighting
|Catalog no. (amps)<br>WCF1RN<br>WCF3RN<br>WCF6RN<br>WCF10RN|Catalog no. (amps)<br>WCF15RN<br>WCF20RN<br>WCF25RN<br>WCF30RN|WCF35RN<br>WCF40RN<br>WCF45RN<br>WCF50RN|WCF60RN<br>WCF70RN<br>WCF80RN<br>WCF90RN|WCF100RN<br>WCF100RN|
|---|---|---|---|---|
Recommended holders for WCF fuses, see page 1-12.
Watts loss at rated current
|Watts loss at rated current|Watts loss at rated current|Watts loss at rated current|
|---|---|---|
|Amps<br>Fuse catalog no.<br>Watts<br>15<br>WCF15RN<br>3.48<br>~~ii~~<br>~~as~~|||
|30|WCF30RN|5.45|
|60|WCF60RN|7.27|
|100|WCF100RN|11.5|
## Operating and storage temperature range
- -40°C to 90°C
## Mounting
The wind CUBEFuse must be mounted in the 690 V WCF holders that are rated for 690 volts. Not to be installed in the CCP2-CF or CCP2B disconnect switches. See page 1-12.
## Time-current characteristic curves — average melt
**==> picture [262 x 522] intentionally omitted <==**
**----- Start of picture text -----**<br>
Amp rating<br>1000<br>ae aan ae a ee<br>ee |<br>100<br>aay eee ae<br>10<br>eeNR ae<br>1<br>Ae<br>aaa<br>0.1<br>QA AAG ALAN 4<br>0.01 UNIAN AAA<br>Current in amps<br>Current limitation curves<br>B<br>100,000<br>100A<br>60A<br>10,000 40A 50A<br>30A<br>15A<br>1000<br>A a ee ee ee<br>100<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>1 3 6 10 15 20 30 40 50 60 100<br>Time in seconds<br>1 10 100 1,000 10,000<br>100 1000<br>Instantaneous peak let-through current in amps 10,000 100,000 300,000<br>**----- End of picture text -----**<br>
Current limitation curves
Data sheet no. 9009 (fuses) and 9007 (holders)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-11
**1 — Low voltage, branch circuit fuses**
## CUBEFuse™ finger-safe fuse holders
**==> picture [23 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
The Bussmann series CUBEFuse holder is a finger-safe modular system of single-pole 30, 60, 100, 200, 225 and 400 amp holders. All holders dovetailed together to create the desired number of poles for the application, including mixed amp ratings between the 30, 60 and 100 amp holders.
The 200, 225 and 400 amp holders require installing lugs to make conductor connections. These are listed on page 1-14.
The CUBEFuse holder is available as the 600 V UL Listed version utilizing the time-delay Low-Peak™ CUBEFuse (TCF up to 400 A) or fast-acting CUBEFuse (FCF up to 100 A), or the 690 V UL Recognized version utilizing the fast-acting wind CUBEFuse (WCF up to 100 A).
## Ratings
- Volts
- 600 Vac / 300 Vdc (UL Listed)
- 690 Vac (UL Recognized up to 100 A)
- Amps
||Catalog no.<br>Max holder amps<br>Fuse amp range<br>600 V UL Listed<br>~~|~~|Catalog no.<br>Max holder amps<br>Fuse amp range<br>600 V UL Listed<br>~~|~~|Catalog no.<br>Max holder amps<br>Fuse amp range<br>600 V UL Listed<br>~~|~~|
|---|---|---|---|
||TCFH30N|30|1-30|
||TCFH60N|60|1-60|
||TCFH100N|100|1-100|
||TCFH200N|200|110-200|
||TCFH225N|225|110-225|
|TCFH400N<br>690 V UL Recognized<br>~~Cc~~||400|110-400|
||TCFH30NW|30|1-30|
||TCFH60NW|60|1-60|
||TCFH100NW|100|1-100|
## Features
- Finger-safe construction for enhanced safety*
- Amp rating rejection helps prevent overfusing by rejecting higher fuse amp ratings
- Smallest installed fuse and holder footprint of any Class J or R installation
- All holders dovetail together to create the required number of poles, mixed 30, 60 and 100 A holders dovetail together
- 30, 60 and 100 A holders have dual wire rated box lug terminals for wiring ease
- 200, 225 and 400 A holders available with a variety of lugs and terminal shrouds for application flexibility
- Up to 300 kA SCCR withstands high fault currents
- 200, 225 and 400 A holders require installed shrouds.
- 30, 60, 100, 200, 225, 400 A
- SCCR
- 300 kA RMS Sym. (30, 60, 100 A UL Listed)
- 200 kA RMS Sym. (200, 225, 400 A UL Listed)
- 200 kA RMS Sym. (CSA[®] Certified 100 A and below)
- 100 kA DC (UL Listed and CSA Certified 100 A and below)
- 50 kA RMS Sym. (UL Recognized)
## Agency information
## 30, 60 and 100 A CUBEFuse holder fuse applications
All 30, 60 and 100 A CUBEFuse holders dovetail together to create the desired number of poles. Each holder accepts CUBEFuse amp ratings up to its rating. E.g., the 60 amp holder will accept a CUBEFuse from 1 to 60 A.
- 600 V UL Listed, Guide IZLT, File E14853
- 690 V UL Recognized, Guide IZLT2, File E14853
> • CSA Certified, Class 6225-01, File 47235, cURus component Certified (30, 60 and 100 A holders)
- CE (100 A and below)
- RoHS compliant
## Mounting
- 35 mm DIN-Rail/panel (Up to 100 A)
- Panel mount (200 to 400 A)
Operating and storage temperature range
- -40°C to 80°C (-40°F to 176°F)
|Holder<br>catalog no.|Volts|CUBEFuse type and amp range<br>TCF and TCF_RN<br>FCF_RN|CUBEFuse type and amp range<br>TCF and TCF_RN<br>FCF_RN|WCF_RN|
|---|---|---|---|---|
|TCFH30N||1-30|1-30||
|TCFH60N|600|1-60|1-60|—|
|TCFH100N||1-100|1-100||
|TCFH30NW||||1-30|
|TCFH60NW|690|—|—|1-60|
|TCFH100NW||||1-100|
Data sheet no. 9007
Eaton.com/bussmannseries
1-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
## ESTO mt
## Conductor ratings and torque for 30, 60 and 100 A holders
Dimensions — in (mm)
Ratings are for 75°C Cu AWG solid/stranded conductors. Torque is in N•m (lb-in).
|Terminal<br>wire<br>rating<br>Holder catalog no.<br>TCFH30N /<br>TCFH30NW<br>TCFH60N /<br>TCFH60NW<br>TCFH100N /<br>TCFH100NW||||
|---|---|---|---|
|Single<br>8-10; 2.8 (25),<br>12-18; 2.6 (20)<br>10-14; 2.6 (20),<br>4-8; 3.9 (35)<br>10-18; 2.6 (20)**,<br>1-8; 4.5 (40)†<br>Dual<br>10-18; 2.8 (25)*<br>10-18; 2.6 (20),<br>6-8; 3.9 (35)<br>6; 5.1 (45)†<br>* 10-18 AWG stranded, 14-18 AWG solid<br>** Solid and stranded<br>† Stranded<br>Recommended Bussmann series fuses<br>~~co~~<br>~~———— ~~||~<br>K<br> ff\|im]<br> igh|
|Type<br>Amp range<br>Data sheet<br>600 volt UL Listed<br>Time-delay indicating Low-Peak™<br>6-100 A<br>9000<br>Time-delay non-indicating Low-Peak<br>1-100 A<br>Fast-acting non-indicating<br>1-100 A<br>2147<br>690 volt UL Recognized<br>Fast-acting wind power<br>1-100 A<br>9009<br>~~EE~~<br>~~OO~~<br>~~as~~<br>~~i~~||0and 60amp holders<br>To<br>ee||
|Amps|H|I|J|K|L|M|Max<br>height<br>with<br>fuse|
|---|---|---|---|---|---|---|---|
|30|2.3(58)|0.76(19)|1.36(34)|0.15(4)|—|—|2.36(60)|
|60|2.6(66)|1.03(26)|1.60(41)|0.17(4)|—|—|2.73(69)|
|100|2.91(74)|1.05(27)|2.01(51)|0.15(4)|0.80(20)|2.51(64)|3.27(83)|
Data sheet no. 9007
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-13
**1 — Low voltage, branch circuit fuses**
## 200, 225 and 400 A CUBEFuse holder fuse applications
**==> picture [71 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal shroud<br>**----- End of picture text -----**<br>
|Holder catalog no.|Volts|CUBEFuse amp range|
|---|---|---|
|TCFH200N||110-200|
|TCFH225N|600 Vac/300 Vdc|110-225|
|TCFH400N||110-400*|
- Achieving 400 A continuous current requires three ganged holders and installed lug catalog number CCP2-L4B-3 to permit the necessary copper conductor size.
## Available lug kits
For complete installation, the 200, 225 and 400 A CUBEFuse holders require lugs. The table below contains the information necessary for ordering the desired lug kit for the application.
## Accessories
**==> picture [17 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lug<br>**----- End of picture text -----**<br>
All 200, 225 and 400 amp holders require installing lugs. Only three ganged holders can accept terminal shrouds. See table below.
|Catalogno.|Holder<br>amps|Description|
|---|---|---|
|CCP2-TS2-3<br>CCP2-PB2<br>CCP2-CWK2|200/225|3-pole terminal shroud<br>Phase barriers (pack of 2)<br>1/4” QC terminals. Use with CCP2-L2-1A,<br>CCP2-MW2-3 and CCP2-MW2-6 lugs (pack of 12)|
|CCP2-TS6-3|400|3-pole terminal shroud|
|CCP2-PB6||Phase barriers (pack of 2)|
## Recommended Bussmann series fuses
|Type|Amp range|Data sheet|
|---|---|---|
|Time-delay indicating Low-Peak|110-400 A|9000|
|Time-delay non-indicating Low-Peak|||
Available lugs, conductor ratings and terminal torques
|Catalog no.<br>Description<br>200/225 A holders|Catalog no.<br>Description<br>200/225 A holders|Lugs per<br>cat. no.|Wire range<br>AWG (mm2)|Wire type/<br>temp.|Conductor<br>torque N•m<br>(lb-in)|Lug mounting screw<br>torque N•m (lb-in)|
|---|---|---|---|---|---|---|
|CCP2-L2-1|Stainless steel lug|1|350-4(185-25)|Cu 75°C|20.3(180)|0.9(8)|
|CCP2-L2-1A|Aluminum lug*|1|350-4(185-25)|Cu/Al 75°C|28.2(250)|13.5(120)|
|CCP2-MW2-3|3-port multi-wire terminal with shroud*†|3|2-14(35-2.5)|Cu/Al 75°C|7.9(70)|10.8(95)|
|CCP2-MW2-6|6-port multi-wire terminal with shroud*†|3|6-14(16-2.5)|Cu/Al 75°C|2.8(25)|10.8(95)|
|* These lugs also acce|s also accept 1/4”quick connect control wire terminals. Order catalo|uick connect control wire terminals. Order catalognumber CCP2-CWK2 (package of 12 terminals).|||||
|400 A holders|||||||
|CCP2-L4-1|Stainless steel lug|1|500-3(240-35)|Cu 75°C|42.0(375)||
|CCP2-L4-1A|Aluminum lug|1|500-3(240-35)|Cu/Al 75°C|42.0(375)||
|CCP2-L4B-3|Stainless steel lugkit with shroud†|3|750-500(400-240)|Cu 75°C|57.0(500)||
|CCP2-L4B-3A|Aluminum lugkit with shroud†|3|750-500(400-240)|Cu/Al 75°C|62.0(550)||
|CCP2-L6-3<br>CCP2-L6-3A|2-port stainless steel lugkit with shroud<br>2-port aluminum lugkit with shroud|3<br>3|(2)500-2(240-35)<br>(2)500-2(240-35)|Cu 75°C<br>Cu/Al 75°C|42.0(375)<br>42.0(375)|22.0 (200)|
||||||10-14 = 3.9 (35)||
|CCP2-MW6-6|6-port multi-wire terminal with shroud†|3|1/0-14 (50-2.5)|Cu/Al 75°C|8 = 4.5(40)<br>4-6 = 5.0(45||
||||||1/0-2 = 5.6(50)||
† This is a lug kit with three lugs and a shroud for installation on three ganged CUBEFuse holders.
Data sheet no. 9007
Eaton.com/bussmannseries
1-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
Dimensions — mm (in)
200/225 A holder
**==> picture [461 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
87.6<br>(3.4)<br>40.7<br>(1.6) (1.0) 25.3 104.84.1)4.1)<br>34.9<br> 2xØ 4.2 (0.2) (1.4)<br>282.6<br>(11.1)<br>23.9 3-pole ganged 200 A holder with installed shroud<br>(0.9)<br>124.5<br>(4.9)<br>**----- End of picture text -----**<br>
**==> picture [262 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
87.6<br>(3.4)<br>104.84.1)4.1) 108.1(4.2)<br>282.6<br>(11.1)<br>**----- End of picture text -----**<br>
## 400 A holder
**==> picture [537 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
99.6<br>(3.9)<br>27.5<br>(1.1) 139.2<br>(5.5)<br> 2xØ 4.2 (0.2) 43.66<br>(1.7)<br>(1.3)33.4 (10.9)276.0<br>3-pole ganged 400 A holder with installed shroud<br>167.7<br>(6 6)<br>**----- End of picture text -----**<br>
Data sheet no. 9007
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-15
**1 — Low voltage, branch circuit fuses**
Ordering a complete 200/225 A holder installation
For a complete installation, select from the following required and optional components, and accessories.
|||Catalog no.|Catalog no.|Catalog no.|
|---|---|---|---|---|
|||Holders|Amps|Poles|
|Required|vi)<br>=“O=|~~Pf~~<br>|<br>Sl<br>wn.|TCFH200N<br>~~Pf~~|200<br>~~Pf~~|1<br>Order required quantity for installation<br>|
|||TCFH225N<br>~~Pf~~<br>|225<br>~~Pf~~<br>||
||~~ss~~|And<br>~~ss~~|||
|||Lug kits<br>~~ss~~|Description<br>~~ss~~||
|||CCP2-L2-1<br>~~ss~~|Stainless steel lug, 75° Cu only, 350 kcmil-4, 1 per pack<br>~~ss~~||
|||CCP2-L2-1A<br>~~ss~~|Aluminum lug, 75°C Cu/Al, 350 kcmil-4, 1 per pack<br>~~ss~~||
|||CCP2-MW2-3<br>~~ss~~|3-port multi-wire lug, 75°C Cu/Al, 2-14, 3 per pack, includes terminal shroud<br>~~ss~~||
|||CCP2-MW2-6<br>~~ss~~|6-port multi-wire lug, 75°C Cu/Al, 6-14, 3 per pack, includes terminal shroud<br>~~ss~~||
|And<br>~~|~~|||||
|Accessories||Terminal shrouds|Description||
|||CCP2-TS2-3|3-pole terminal shroud with phase shields, 1 per pack||
|||Phase barriers|Description||
|||CCP2-PB2|Phase barriers, 2 per pack||
||And||||
|||Control terminals|Description||
|||CCP2-CWK2|1/4” quick-connect control wire terminals - mounts on installed lug (cannot be used<br>with lug CCP2-L2-3), 12 per pack||
Data sheet no. 9007
Eaton.com/bussmannseries
1-16
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
## Ordering a complete 400 A holder installation
For a complete installation, select from the following required and optional components, and accessories.
|||Catalog no.|Catalog no.|Catalog no.|
|---|---|---|---|---|
|||Holder|Amps|Poles|
|Required|L<br>aa|TCFH400N|400|1<br>Order required quantity for installation|
|||And|||
|||Lug kits|Description||
|||CCP2-L4-1|Stainless steel lug, 75° Cu only, 500 kcmil-3, 1 per pack||
|||CCP2-L4-1A|Aluminum lug, 75° Cu only, 500 kcmil-3, 1 per pack||
|||CCP2-L4B-3|Stainless steel lug, 75° Cu only, 750-500 kcmil, 3 per pack, includes terminal shroud||
|||CCP2-L4B-3A|Aluminum lug, 75°C Cu/Al, 750-500 kcmil, 3 per pack, includes terminal shroud||
|||CCP2-L6-3|2-port stainless steel lug, 75° Cu only, 500 kcmil-2, 3 per pack, includes terminal shroud||
|||CCP2-L6-3A|2-port aluminum lug, 75°C Cu/Al, 500 kcmil-2, 3 per pack, includes terminal shroud||
|||CCP2-MW6-6|6-port multi-wire lug, 75°C Cu/Al, 1/0-14, 3 per pack, includes terminal shroud||
|And<br>~~et~~|||||
|Accessories||Terminal<br>shrouds|Description||
|||CCP2-TS6-3|3-pole terminal shroud with phase shields, 1 per pack||
|||Phase barriers|Description||
|||CCP2-PB6|Phase barriers, 2 per pack||
Data sheet no. 9007
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-17
## **1 — Low voltage, branch circuit fuses**
## SC Class G general purpose fuses
Time-current characteristics — average melt
Fast-acting (1/2-6 A) and time-delay (7-60 A) Class G fuses. SC fuses are size rejecting measuring 13/32" in diameter by various lengths associated with their amp rating ranging from 1-5/16" to 2-1/4". This feature helps prevent overfusing. See the catalog numbers table for length by amp rating.
## Ratings
- Volts
- 600 Vac (1/2-20 A)
- 480 Vac (25-60 A)
- 170 Vdc (1/2-20 A)
- 300 Vdc (25-60 A)
**==> picture [22 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- Amps 1/2-60 A
**==> picture [16 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
• IR<br>**----- End of picture text -----**<br>
- 100 kA RMS Sym.
- 10 kA DC
## Agency information
- UL Listed Std 248-5, Class G, Guide JDDZ, File E4273, CSA Certified, Class 1422-01, File 53787, RoHS compliant, CE
## Features
- Class G current limiting for component and branch circuit protection
- 100 kA interrupting rating provides cost-effective branch circuit fusing for systems with high short-circuit current levels
- Rejection feature with variations in length helps prevent overfusing
## Current limitation curves
## Typical applications
- Fusible branch circuit panelboards
> • HVAC branch circuit protection
Catalog no. (amps) and length 1-5/16" 1-13/32" 1-5/8" 2-1/4" ~~eee~~ SC-1/2 SC-20 SC-25 SC-35 ~~A~~ SC-1 SC-30 SC-40 ~~a~~ SC-1-1/2 SC-45 SC-2 SC-50 SC-2-1/2 SC-60
SC-3 SC-4 SC-5 SC-6 SC-7 SC-8 SC-10 SC-12 SC-15
**==> picture [261 x 206] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>100,000 SS A A OS CR” SS 60A<br>Sea ee esos eee 2 ee al<br>aeea a2eeee 20A30A<br>15A<br>Po eT eel<br>EN)<br>1000 aSellen a eal<br>_————<br>| |rE<br>cae = ee ee eee<br>a Aan 0 8 ee<br>ey a<br>A PAL<br>100<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>A-B = Asymmetrical available peak (2.3 x Sym. RMS Amps)<br>Instantaneous peak let-through current in amps 100 1000 10,000<br>100,000<br>**----- End of picture text -----**<br>
Recommended holders and blocks for Class G fuses, see page 1-2.
Data sheet no. 1024
Eaton.com/bussmannseries
1-18
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
Time-current characteristics — average melt
## LPJ_SP Class J Low-Peak dual-element, time-delay fuses
**==> picture [276 x 549] intentionally omitted <==**
**----- Start of picture text -----**<br>
Amp rating<br>300<br>200 aC EE a A<br>100<br>FAAAAMAATA<br>AAA HH<br>10<br>pO<br>1<br>pa<br>0.1<br>a ees ee es eet ee ee at<br>SSA<br>poe OEE Py<br>0.01 AAEM<br>Current in amps<br>Current limitation curves<br>B<br>100,000<br>600A<br>400A<br>200A<br>100A<br>PC te<br>60A<br>10,000<br>30A<br>15A<br>1000<br>A<br>100<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>1 3 6 10 15 30 60 80 100 125 200 250 400 600<br>Low voltage,<br>branch circuit fuses<br>Time in seconds<br>1 10 100 1000 10,000<br>Instantaneous peak let-through current in amps<br>100 1000 10,000 100,000 200,000 300,000<br>**----- End of picture text -----**<br>
Dual-element, time-delay Class J fuse; 10 seconds (minimum) at 500% rated amps, available with optional indication on select ratings (see catalog numbers table). For dimensions, see page 1-3.
## Ratings
- Volts
- 600 Vac (or less)
- 300 Vdc (or less)*
- Amps 1-600 A
**==> picture [22 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- IR
- 300 kA RMS Sym.
- 100 kA DC
- Does not apply to indicating versions.
## Agency information
- UL Listed, Guide JDDZ, File E4273, CSA Certified Class J per CSA 22.2 No 248.8, Class 1422-02, File 53787, RoHS compliant, CE
## Features
- Separate overload and short-circuit elements provide time delay for sizing of high inrush loads linked with Class J current limitation
- Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit
## Current limitation curves
- Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer
## Typical applications
- Power panelboards
- Branch circuit breaker panelboard mains
- Machinery disconnects
> • Industrial control
|Catalog no. (amps)<br>LPJ-1SP<br>LPJ-4-1/2SP<br>LPJ-25SP*<br>LPJ-125SP*<br>LPJ-1-1/4SP<br>LPJ-5SP<br>LPJ-30SP*<br>LPJ-150SP*<br>LPJ-1-6/10SP<br>LPJ-5-6/10SP<br>LPJ-35SP*<br>LPJ-175SP*<br>LPJ-1-8/10SP<br>LPJ-6SP*<br>LPJ-40SP*<br>LPJ-200SP*<br>LPJ-2SP<br>LPJ-7SP*<br>LPJ-45SP*<br>LPJ-225SP*<br>LPJ-2-1/4SP<br>LPJ-8SP*<br>LPJ-50SP*<br>LPJ-250SP*<br>LPJ-2-1/2SP<br>LPJ-9SP*<br>LPJ-60SP*<br>LPJ-300SP*<br>A<br>100<br>1000<br>100<br>1000<br>10,000<br>100,000<br>300,000<br>Instantaneous peak let-through current in amps<br>200,000<br>~~i~~<br>~~7~~<br>~~a~~|Catalog no. (amps)<br>LPJ-1SP<br>LPJ-4-1/2SP<br>LPJ-25SP*<br>LPJ-125SP*<br>LPJ-1-1/4SP<br>LPJ-5SP<br>LPJ-30SP*<br>LPJ-150SP*<br>LPJ-1-6/10SP<br>LPJ-5-6/10SP<br>LPJ-35SP*<br>LPJ-175SP*<br>LPJ-1-8/10SP<br>LPJ-6SP*<br>LPJ-40SP*<br>LPJ-200SP*<br>LPJ-2SP<br>LPJ-7SP*<br>LPJ-45SP*<br>LPJ-225SP*<br>LPJ-2-1/4SP<br>LPJ-8SP*<br>LPJ-50SP*<br>LPJ-250SP*<br>LPJ-2-1/2SP<br>LPJ-9SP*<br>LPJ-60SP*<br>LPJ-300SP*<br>A<br>100<br>1000<br>100<br>1000<br>10,000<br>100,000<br>300,000<br>Instantaneous peak let-through current in amps<br>200,000<br>~~i~~<br>~~7~~<br>~~a~~|Catalog no. (amps)<br>LPJ-1SP<br>LPJ-4-1/2SP<br>LPJ-25SP*<br>LPJ-125SP*<br>LPJ-1-1/4SP<br>LPJ-5SP<br>LPJ-30SP*<br>LPJ-150SP*<br>LPJ-1-6/10SP<br>LPJ-5-6/10SP<br>LPJ-35SP*<br>LPJ-175SP*<br>LPJ-1-8/10SP<br>LPJ-6SP*<br>LPJ-40SP*<br>LPJ-200SP*<br>LPJ-2SP<br>LPJ-7SP*<br>LPJ-45SP*<br>LPJ-225SP*<br>LPJ-2-1/4SP<br>LPJ-8SP*<br>LPJ-50SP*<br>LPJ-250SP*<br>LPJ-2-1/2SP<br>LPJ-9SP*<br>LPJ-60SP*<br>LPJ-300SP*<br>A<br>100<br>1000<br>100<br>1000<br>10,000<br>100,000<br>300,000<br>Instantaneous peak let-through current in amps<br>200,000<br>~~i~~<br>~~7~~<br>~~a~~|Catalog no. (amps)<br>LPJ-1SP<br>LPJ-4-1/2SP<br>LPJ-25SP*<br>LPJ-125SP*<br>LPJ-1-1/4SP<br>LPJ-5SP<br>LPJ-30SP*<br>LPJ-150SP*<br>LPJ-1-6/10SP<br>LPJ-5-6/10SP<br>LPJ-35SP*<br>LPJ-175SP*<br>LPJ-1-8/10SP<br>LPJ-6SP*<br>LPJ-40SP*<br>LPJ-200SP*<br>LPJ-2SP<br>LPJ-7SP*<br>LPJ-45SP*<br>LPJ-225SP*<br>LPJ-2-1/4SP<br>LPJ-8SP*<br>LPJ-50SP*<br>LPJ-250SP*<br>LPJ-2-1/2SP<br>LPJ-9SP*<br>LPJ-60SP*<br>LPJ-300SP*<br>A<br>100<br>1000<br>100<br>1000<br>10,000<br>100,000<br>300,000<br>Instantaneous peak let-through current in amps<br>200,000<br>~~i~~<br>~~7~~<br>~~a~~|Catalog no. (amps)<br>LPJ-1SP<br>LPJ-4-1/2SP<br>LPJ-25SP*<br>LPJ-125SP*<br>LPJ-1-1/4SP<br>LPJ-5SP<br>LPJ-30SP*<br>LPJ-150SP*<br>LPJ-1-6/10SP<br>LPJ-5-6/10SP<br>LPJ-35SP*<br>LPJ-175SP*<br>LPJ-1-8/10SP<br>LPJ-6SP*<br>LPJ-40SP*<br>LPJ-200SP*<br>LPJ-2SP<br>LPJ-7SP*<br>LPJ-45SP*<br>LPJ-225SP*<br>LPJ-2-1/4SP<br>LPJ-8SP*<br>LPJ-50SP*<br>LPJ-250SP*<br>LPJ-2-1/2SP<br>LPJ-9SP*<br>LPJ-60SP*<br>LPJ-300SP*<br>A<br>100<br>1000<br>100<br>1000<br>10,000<br>100,000<br>300,000<br>Instantaneous peak let-through current in amps<br>200,000<br>~~i~~<br>~~7~~<br>~~a~~|Catalog no. (amps)<br>LPJ-1SP<br>LPJ-4-1/2SP<br>LPJ-25SP*<br>LPJ-125SP*<br>LPJ-1-1/4SP<br>LPJ-5SP<br>LPJ-30SP*<br>LPJ-150SP*<br>LPJ-1-6/10SP<br>LPJ-5-6/10SP<br>LPJ-35SP*<br>LPJ-175SP*<br>LPJ-1-8/10SP<br>LPJ-6SP*<br>LPJ-40SP*<br>LPJ-200SP*<br>LPJ-2SP<br>LPJ-7SP*<br>LPJ-45SP*<br>LPJ-225SP*<br>LPJ-2-1/4SP<br>LPJ-8SP*<br>LPJ-50SP*<br>LPJ-250SP*<br>LPJ-2-1/2SP<br>LPJ-9SP*<br>LPJ-60SP*<br>LPJ-300SP*<br>A<br>100<br>1000<br>100<br>1000<br>10,000<br>100,000<br>300,000<br>Instantaneous peak let-through current in amps<br>200,000<br>~~i~~<br>~~7~~<br>~~a~~|
|---|---|---|---|---|---|
|LPJ-2-8/10SP|LPJ-10SP*|LPJ-70SP*|LPJ-350SP*||Prospective short-circuit current (Symmetrical RMS Amps)|
|LPJ-3SP|LPJ-12SP*|LPJ-80SP*|LPJ-400SP*|||
|LPJ-3-2/10SP|LPJ-15SP*|LPJ-90SP*|LPJ-450SP*|||
|LPJ-3-1/2SP|LPJ-17-1/2SP*|LPJ-100SP*|LPJ-500SP*|||
|LPJ-4SP|LPJ-20SP*|LPJ-110SP*|LPJ-600SP*|||
*Available with optional permanent replace fuse indication To order, place "I" at end of catalog number Example: LPJ-6SPI. Available with silver plated terminals Add SP/ in front of catalog number.
Recommended holders and blocks for Class J fuses, see page 1-2.
Data sheet no. 1006 (0-60 A) and 1007 (70-600 A)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-19
**1 — Low voltage, branch circuit fuses**
## JKS Class J Limitron™ fast-acting fuses
Fast-acting, Class J current-limiting fuse. For superior electrical protection, Eaton recommends upgrading JKS fuse applications to Bussmann series Low-Peak LPJ fuses See page 1-19. For dimensions, see page 1-3.
## Ratings
- Volts 600 Vac (or less)
- Amps 1-600 A
- IR 200 kA RMS Sym.
Agency information
- 600 Vac, UL Listed, Std. 248-8, Class J, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787, CE
Features
- Current limitation for non-inductive circuits provides Class J current-limiting response to maximum ground fault and shortcircuit conditions
- 200 kA interrupting rating provides protection at all circuit locations
- Economical circuit protection for high-fault current circuits
Typical applications
> • Power panelboards
- Machinery disconnects
- ~~ee~~ Catalog no. (amps)
|Catalog no. (amps)<br>JKS-1<br>JKS-15<br>JKS-70<br>JKS-225<br>~~ee~~|
|---|
|JKS-2<br>JKS-20<br>JKS-80<br>JKS-250|
|JKS-3<br>JKS-25<br>JKS-90<br>JKS-300|
|JKS-4<br>JKS-30<br>JKS-100<br>JKS-350<br>JKS-5<br>JKS-35<br>JKS-110<br>JKS-400<br>JKS-6<br>JKS-40<br>JKS-125<br>JKS-450<br>JKS-8<br>JKS-45<br>JKS-150<br>JKS-500<br>JKS-10<br>JKS-50<br>JKS-175<br>JKS-600<br>JKS-12<br>JKS-60<br>JKS-200<br>Recommended holders and blocks for JKS Class J fuses, see page<br>1-2.<br>~~I~~<br>~~__—_—_—.~~<br>~~—~~<br>~~OO~~<br>~~ooo~~|
## Time-current characteristics — average melt
**==> picture [173 x 345] intentionally omitted <==**
**----- Start of picture text -----**<br>
Amp rating<br>300 Tt Oa<br>JKS<br>100<br>CVT VTA<br>POIAORTIC<br>10<br>LONAEE<br>EL LACE<br>1<br>eect eee eee ee ee<br>sciiinct<br>CAT,at eeACTail<br>0.1<br>NAPHN A<br>0.01 TIEAEPACES AAT<br>NTA<br>Current in amps<br>30 60 100 200 400 600<br>Time in seconds<br>40 100 1000 10,000<br>**----- End of picture text -----**<br>
## Current limitation curves
**==> picture [259 x 279] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>400,000<br>CO oe<br>ae<br>100,000 AE EE<br>600A<br>EE<br>CI Ze 400A<br>200A<br>100A<br>—H a<br>60A<br>10,000 ere<br>30A<br>aae<br>Perret<br>A<br>tae ee<br>ea<br>1000 aT lllll |LLIN<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>A-B = Asymmetrical available peak (2.3 x Sym. RMS Amps)<br>Instantaneous peak let-through current in amps<br>1000 10,000 100,000 200,000<br>**----- End of picture text -----**<br>
Data sheet no. 1026 (1-60 A) and 1027 (70-600 A)
Eaton.com/bussmannseries
1-20
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
## NON and NOS Class K5/H general purpose onetime fuses
General purpose, Class K5 and H non-current-limiting fuse 250 V NON and 600 V NOS fuses. For superior electrical protection, Eaton recommends upgrading NON (250 Vac) and NOS (600 Vac) fuse applications to Bussmann series Low-Peak LPN-RK (250 Vac) and LPS-RK (600 Vac) fuses, see pages 1-24 to 1-26. For dimensions, see page 1-3.
## Ratings
- Volts
- NON
- −250 Vac
- −125 Vdc (0-100 A)
- NOS −600 Vac
- Amps 1/8-600 A
## • IR
- 50 kA RMS Sym. (NON and NOS 0-60 A)
- 10 kA RMS Sym. (NON and NOS 65-600 A)
- 50 kA @ 125 Vdc (NON 0-60 A)
- 10 kA @ 125 Vdc (NON 65-100 A)
## Agency information
- UL Listed
- 250 V Class K5 (0-60 A), Std 248-9, Class H (65-600 A), Std 248-6, (125 Vac, NON 0-100 A)
- 600 V Class K5 (0-60 A), Std 248-9, Class H (70-600 A), Std 248-6, Guide JDDZ, File E4273
|Catalog no. (amps)||||
|---|---|---|---|
|250 V NON<br>NON-1/8<br>NON-1/2<br>NON-3/4<br>NON-8/10|NON-5<br>NON-6<br>NON-6-1/4<br>NON-7|NON-40<br>NON-45<br>NON-50<br>NON-60|NON-175<br>NON-200<br>NON-225<br>NON-250|
|NON-1|NON-8|NON-65|NON-300|
|NON-1-1/4|NON-9|NON-70|NON-350|
|NON-1-1/2|NON-10|NON-75|NON-400|
|NON-1-6/10|NON-12|NON-80|NON-450|
|NON-2|NON-15|NON-90|NON-500|
|NON-2-1/2|NON-20|NON-100|NON-600|
|NON-3<br>NON-3-2/10<br>NON-4<br>600 V NOS|NON-25<br>NON-30<br>NON-35|NON-110<br>NON-125<br>NON-150||
|NOS-1|NOS-12|NOS-70|NOS-200|
|NOS-2|NOS-15|NOS-75|NOS-225|
|NOS-3|NOS-20|NOS-80|NOS-250|
|NOS-4|NOS-25|NOS-90|NOS-300|
|NOS-5|NOS-30|NOS-100|NOS-350|
|NOS-6|NOS-35|NOS-110|NOS-400|
|NOS-7|NOS-40|NOS-125|NOS-450|
|NOS-8|NOS-45|NOS-150|NOS-500|
|NOS-9|NOS-50|NOS-175|NOS-600|
|NOS-10|NOS-60|||
## Recommended fuse reducers
- CSA Certified
- 250 V (0-12, 65-600 A)†
- 600 V (0-600 A), Class 1421-01, File 53787
## • CE
- For CSA Certified 15-60 A ratings, see PON in Section 5, page 2.
## Features
- Basic overcurrent protection.
## Typical applications
- Light duty circuit locations
|250 V|600 V|
|---|---|
|Fuse<br>amps<br>Clip amp<br>size<br>Catalog<br>no. (pair)|Fuse<br>amps<br>Clip amp<br>size<br>Catalog<br>no. (pair)|
|30<br>60<br>NO.263|30<br>60<br>NO.663|
|30<br>100<br>NO.213|30<br>100<br>NO.216|
|60<br>100<br>NO.216|60<br>100<br>NO.616|
|60<br>200<br>NO.226|60<br>200<br>NO.626|
|100<br>200<br>NO.2621|100<br>200<br>NO.2621|
|100<br>400<br>NO.2641|100<br>400<br>NO.2641|
|200<br>400<br>NO.2642|200<br>400<br>NO.2642|
|100<br>600<br>NO.2661|100<br>600<br>NO.2661|
|200<br>600<br>NO.2662|200<br>600<br>NO.2662|
|400<br>600<br>NO.2664|400<br>600<br>NO.2664|
Recommended blocks for Class K5 and H fuses, see page 1-2.
Data sheet no. 1030
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-21
**1 — Low voltage, branch circuit fuses**
## KRP-C_SP Class L Low-Peak time-delay fuses
## Time-current characteristics — average melt
**==> picture [239 x 653] intentionally omitted <==**
**----- Start of picture text -----**<br>
Amp rating<br>300 YY<br>100<br>AW<br>10<br>AWAY<br>1<br>—— VE<br>0.1<br>LEIA<br>0.01 TAWA<br>J<br>Current in amps<br>Current limitation curves<br>1,000,000<br>B<br>6000A<br>EE 5000A<br>4000A<br>3000A<br>pedi | ype 2500A<br>2000A<br>100,000 1600A<br>1200A<br>800A<br>601A<br>ae<br>10,000<br>CACHE<br>A<br>rT LT tT<br>1000 LIE ELTA<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>800 1200 1600 2000 2500 3000 4000 5000 6000<br>Time in seconds<br>1000 10,000 100,000 200,000<br>Instantaneous peak let-through current in amps<br>1000 10,000 100,000 200,000 300,000<br>**----- End of picture text -----**<br>
Time-delay Class L fuses — 4 seconds (minimum) at 500% rated amps. Use KRP-CL for current ratings under 601 A. For dimensions, see page 1-4.
## Ratings
- Volts
- 600 Vac (or less)
**==> picture [34 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>@><br>**----- End of picture text -----**<br>
- 300 Vdc (601-2000 A, 3000 A)
- Amps 601-6000 A
- IR
- 300 kA RMS Sym.
- 100 kA DC
## Agency information
- UL Listed 248-10, Guide JFHR, File E56412, CSA Certified, Class 1422-02, File 53787, Class L per CSA C22.2, No 248.10, RoHS compliant, CE
## Features
- Time-delay of 4 seconds at 5 times rating allows closer sizing on large motor loads combined with Class L current limitation
- Selective coordination ratio of 2:1 (within Low-Peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit
- Interrupting rating of 300 kA RMS symmetrical provides adequate ratings without obsolescence for all electrical systems, big or small
- Quality construction, using high-grade materials, provides lower watts loss and operating temperatures with superior arc quenching during current-limiting action
## Current limitation curves
## Typical applications
- Large distribution switchboards
- Power panelboards
- Large machinery disconnects
|Catalog no. (amps)<br>KRP-C-601SP<br>KRP-C-1000SP<br>KRP-C-1800SP<br>KRP-C-3500SP<br>KRP-C-650SP<br>KRP-C-1100SP<br>KRP-C-1900SP<br>KRP-C-4000SP<br>KRP-C-700SP<br>KRP-C-1200SP<br>KRP-C-2000SP<br>KRP-C-4500SP<br>KRP-C-750SP<br>KRP-C-1350SP<br>KRP-C-2001SP<br>KRP-C-5000SP<br>KRP-C-800SP<br>KRP-C-1400SP<br>KRP-C-2400SP<br>KRP-C-6000SP<br>KRP-C-801SP<br>KRP-C-1500SP<br>KRP-C-2500SP<br>KRP-C-900SP<br>KRP-C-1600SP<br>KRP-C-3000SP<br>Recommended blocks for Class L fuses, see page 1-2.<br>A<br>10,000<br>100,000<br>Instantaneous peak let-through current in amps<br>~~ee~~<br>ae<br>~~er~~<br>~~oo~~<br>CACHE<br>rT LTLT<br>tT|
|---|
Recommended blocks for Class L fuses, see page 1-2.
Data sheet no. 1008(601-2000 A) and 1009 (2001-6000 A)
Eaton.com/bussmannseries
1-22
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
## KRP-CL current-limiting, time-delay fuses
Current-limiting, time-delay fuse with Class L dimensions for the 601-800 A case size. For dimensions, see page 1-4.
## Ratings
- Volts 600 Vac (or less)
- Amps 225-600 A
- IR 200 kA RMS Sym.
**==> picture [23 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
## Agency information
- RoHS compliant
## Features
- Time-delay of 4 seconds at 5 times rating allows closer sizing inductive loads coupled with an equivalent Class L current limitation
- 601 to 800 A Class L case size permits applying circuit protection from 225 to 600 A for downsize fusing of 800 amp Class L fused switches
## Typical applications
- Large distribution switchboards
- Power panelboards
> • Machinery disconnects
## KTU Class L Limitron fast-acting fuses
Fast-acting, Class L fuses. For superior electrical protection, Eaton recommends upgrading KTU fuse applications to Bussmann series Low-Peak KRP-C fuses, see page 1-22. For dimensions, see page 1-4.
## Ratings
- Volts 600 Vac (or less)
- Amps 601-6000 A **2011/65/EU**
- IR 200 kA RMS Sym.
Agency information
- UL Listed, Std 248-10, Class L, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787, RoHS compliant, CE
## Features
- 200 kA interrupting rating provides protection at all circuit locations
- Economical protection for high-fault current circuits
- Quality construction using high-grade materials provides lower watts loss and operating temperatures with superior arc quenching during current-limiting action
## Typical applications
- Large distribution switchboards
- Power panelboards
|Catalog no. (amps)<br>~~|~~|Catalog no. (amps)<br>~~|~~|Catalog no. (amps)<br>~~|~~|Catalog no. (amps)<br>~~|~~|Catalog no. (amps)<br>~~|~~|Catalog no. (amps)||||
|---|---|---|---|---|---|---|---|---|
|KRP-CL-225|KRP-CL-300|KRP-CL-400|KRP-CL-500||KTU-601|KTU-850|KTU-1500|KTU-2500|
|KRP-CL-250|KRP-CL-350|KRP-CL-450|KRP-CL-600||KTU-650|KTU-900|KTU-1600|KTU-3000|
|Recommended blocks for Class L fuses, see page 1-2.|||||KTU-700|KTU-1000|KTU-1800|KTU-3500|
||||||KTU-750|KTU-1100|KTU-2000|KTU-4000|
||||||KTU-800|KTU-1200|KTU-2001|KTU-5000|
||||||KTU-801|KTU-1400|KTU-2400|KTU-6000|
Recommended blocks for Class L fuses, see page 1-2.
Data sheet no. 1016
Data sheet no. 1010
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-23
## **1 — Low voltage, branch circuit fuses** ata st KLU Class Limitron time-delay fuses LPN-RK_SP (250 V) and LPS-RK_SP (600 V) Class RK1 Low-Peak dual-element, time-delay fuses
Time-delay, Class L fuses - 5 seconds (minimum) at 500% rated amps. For superior electrical protection, Eaton recommends upgrading KLU fuse applications to Bussmann series Low-Peak KRP-C fuses, see page 1-22. Use KRP-CL for current ratings under 601 A. For dimensions, see page 1-4.
Current-limiting, dual-element, time-delay Class RK1 fuses; 10 seconds (minimum) at 500% rated amps (8 seconds for 0-30 A sizes). Available with optional indication on select ratings (see catalog numbers table). For dimensions, see page 1-3.
## Ratings
## Ratings
- Volts 600 Vac (or less)
- Volts
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- Amps 601-4000 A
- LPN-RK
- −250 Vac (or less)
- IR 200 kA RMS Sym.
- −125 Vdc* (0-60 A)
## Agency information
- −250 Vdc* (70-600 A)
- UL Listed, Std 248-10, Class L, Guide JDDZ, File E4273, CSA Certified, CSA Class 1422-02, File 53787, RoHS compliant, CE
- LPS-RK −600 Vac (or less)
- −300 Vdc*
## Features
- Amps 1/10-600 A
- 200 kA interrupting rating provides protection at all circuit locations
- Economical protection for high-fault current circuits
## Typical applications
- Large distribution switchboards
- Power panelboards
> • Large machinery disconnects
|Catalog no. (amps)<br>~~SS~~|Catalog no. (amps)<br>~~SS~~|Catalog no. (amps)<br>~~SS~~|Catalog no. (amps)<br>~~SS~~|
|---|---|---|---|
|KLU-601|KLU-1000|KLU-1800|KLU-4000|
|KLU-650|KLU-1200|KLU-2000||
|KLU-700|KLU-1500|KLU-2500||
|KLU-800|KLU-1600|KLU-3000||
Recommended blocks for Class L fuses, see page 1-2.
- IR
- 300 kA RMS Sym.
- 100 kA DC
- Does not apply to indicating versions.
## Agency information
- UL Listed, Guide JDDZ, File E4273, CSA Certified, Class RK1 per CSA C22.2, No 248.12, Class 1422-02, File 53787, CE
## Features
- Separate overload and short-circuit elements provide time delay for close sizing of high inrush loads linked with RK1 current-limitation and selective coordination ratio of 2:1 (within Low-Peak fuse family) helps prevent widespread blackouts
- Inventory consolidation of Class RK1, RK5 and H fuses for reduced SKU investment and minimizing potential for misapplying fuse
- 300 kA RMS symmetrical interrupting rating provides adequate ratings without obsolescence for all electrical systems, big or small
- Insulated end caps reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
## Typical applications
- Large distribution switchboards
- Power panelboards
- Motor control centers
- Machinery disconnect switches
Data sheet no. LPN; 1003 (up to 60 A), 1007 (70-600 A) LPS 1001 (up to 60 A), 1002 (70-600 A)
Data sheet no. 1013
Eaton.com/bussmannseries
1-24
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
## ~~ee~~ Catalog no. (amps)
LPN Time-current characteristics — average melt
|Catalog no. (amps)g no. (amps)no. (amps)(amps)amps)ps)s))<br>~~ee~~|~~ee~~|LPN Time-current characteristics — average melt|LPN Time-current characteristics — average melt|LPN Time-current characteristics — average melt|LPN Time-current characteristics — average melt|LPN Time-current characteristics — average melt||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|250 V LPN-RK*<br>LPN-RK-1/10SP<br>LPN-RK-2-1/4SP<br>LPN-RK-12SP<br>LPN-RK-110SP**<br>LPN-RK-15/100SP<br>LPN-RK-2-1/2SP<br>LPN-RK-15SP<br>LPN-RK-125SP**<br>LPN-RK-2/10SP<br>LPN-RK-2-8/10SP<br>LPN-RK-17-1/2SP<br>LPN-RK-150SP**<br>LPN-RK-3/10SP<br>LPN-RK-3SP<br>LPN-RK-20SP<br>LPN-RK-175SP**<br>LPN-RK-4/10SP<br>LPN-RK-3-2/10SP<br>LPN-RK-25SP<br>LPN-RK-200SP**<br>LPN-RK-1/2SP<br>LPN-RK-3-1/2SP<br>LPN-RK-30SP<br>LPN-RK-225SP**<br>~~ee~~<br>~~ee~~||300<br>100|||1<br>2<br>4<br>5<br>8<br>10<br>12<br>1-1/4<br>1-6/10<br>2-1/2<br>3-2/10<br>6-1/4<br>LPN-RK amp rating<br>1/10<br>15/100<br>2/10<br>3/10<br>4/10<br>1/2<br>6/10<br>8/10<br>VAANAT|||||||||||
|LPN-RK-6/10SP<br>LPN-RK-4SP<br>LPN-RK-35SP**<br>LPN-RK-250SP**||||||||||||||||
|LPN-RK-8/10SP<br>LPN-RK-4-1/2SP<br>LPN-RK-40SP**<br>LPN-RK-300SP**||||—ARAN||ARAN||||||||||
|LPN-RK-1SP<br>LPN-RK-5SP<br>LPN-RK-45SP**<br>LPN-RK-350SP**||||||||||||||||
|LPN-RK-1-1/8SP<br>LPN-RK-5-6/10SP<br>LPN-RK-50SP**<br>LPN-RK-400SP**<br>LPN-RK-1-1/4SP<br>LPN-RK-6SP<br>LPN-RK-60SP**<br>LPN-RK-450SP**|||10|||||||||||||
|||||||||||||||||
|LPN-RK-1-4/10SP<br>LPN-RK-6-1/4SP<br>LPN-RK-70SP**<br>LPN-RK-500SP**<br>LPN-RK-1-6/10SP<br>LPN-RK-8SP<br>LPN-RK-80SP**<br>LPN-RK-600SP**<br>LPN-RK-1-8/10SP<br>LPN-RK-9SP<br>LPN-RK-90SP**<br>LPN-RK-2SP<br>LPN-RK-10SP<br>LPN-RK-100SP**<br>600 V LPS-RK<br>LPS-RK-1/10SP<br>LPS-RK-2-1/4SP<br>LPS-RK-10SP**<br>LPS-RK-100SP**<br>LPS-RK-2/10SP<br>LPS-RK-2-1/2SP<br>LPS-RK-12SP**<br>LPS-RK-110SP**<br>LPS-RK-3/10SP<br>LPS-RK-2-8/10SP<br>LPS-RK-15SP**<br>LPS-RK-125SP**<br>LPS-RK-4/10SP<br>LPS-RK-3SP<br>LPS-RK-17-1/2SP**<br>LPS-RK-150SP**<br>~~— NNN~~<br>~~CC~~<br>~~Sse~~||Time in seconds|1<br>0.1|SSA<br>PTT VAT<br>AVEC<br>AVAAT<br>AAWANG||||||||||||
|LPS-RK-1/2SP<br>LPS-RK-3-2/10SP<br>LPS-RK-20SP**<br>LPS-RK-175SP**||||||||||||||||
|||||||||||||||||
|LPS-RK-6/10SP<br>LPS-RK-3-1/2SP<br>LPS-RK-25SP**<br>LPS-RK-200SP**<br>LPS-RK-8/10SP<br>LPS-RK-4SP<br>LPS-RK-30SP**<br>LPS-RK-225SP**<br>LPS-RK-1SP<br>LPS-RK-4-1/2SP<br>LPS-RK-35SP**<br>LPS-RK-250SP**<br>LPS-RK-1-1/8SP<br>LPS-RK-5SP<br>LPS-RK-40SP**<br>LPS-RK-300SP**<br>LPS-RK-1-1/4SP<br>LPS-RK-5-6/10SP<br>LPS-RK-45SP**<br>LPS-RK-350SP**<br>~~ee~~<br>~~a~~<br>~~3.~~||0.01<br>0.1||||1<br>10<br>100<br>1000<br>SEPENIAC<br>OEE AEN AACA AC ANN<br>T**N**T<br>E UIIN,ANUJ, ALLAN||||||||||
|LPS-RK-1-4/10SP<br>LPS-RK-6SP**<br>LPS-RK-50SP**<br>LPS-RK-400SP**||||||Current in amps||||||||||
|LPS-RK-1-1/2SP<br>LPS-RK-6-1/4SP**<br>LPS-RK-60SP**<br>LPS-RK-450SP**||||||||||||||||
|LPS-RK-1-6/10SP<br>LPS-RK-7SP**<br>LPS-RK-70SP**<br>LPS-RK-500SP**||||||||||||||||
|LPS-RK-1-8/10SP<br>LPS-RK-8SP**<br>LPS-RK-80SP**<br>LPS-RK-600SP**||||||||||||||||
|LPS-RK-2SP<br>LPS-RK-9SP**<br>LPS-RK-90SP**||||||||||||||||
- ~~TN~~ * 0-60 A fuses available with Nickel plate option. Example: LPS-RK30SPNP). 70-600 A fuses available with tin-plate option. Example: LPS-RK-100SP-TP.
- ** Available with optional indication; to order, place "I" at end of catalog number Example: LPN-RK-35SPI or LPS-RK-15SPI.
Recommended blocks for Class RK1 fuses, see page 1-2.
Data sheet no. LPN-RK 1003 (up to 60 A), 1007 (70-600 A) LPS-RK 1001 (up to 60 A), 1002 (70-600 A)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-25
**1 — Low voltage, branch circuit fuses**
LPS Time-current characteristics — average melt
## LPN Current limitation curves
**==> picture [229 x 305] intentionally omitted <==**
**----- Start of picture text -----**<br>
LPS-RK amp rating<br>300<br>\<br>| \| \ \<br>100<br>AAAN1 AN \<br>NAAR AQAA ||<br>10 MAY<br>1 OO \ \\\<br>Sse eeeiieAANUIAANee oe cess sven oe CNYSoest eetemeei<br>“HARA AGE<br>LENIN AN \<br>0.1<br>0.01 SETAELTHAM | LNT,AATNN ANUIN,ACTAALLEN<br>Current in amps<br>2/10 1/2 6/10 1-1/4 2 6-1/4 10<br>1/10 3/10 4/10 8/10 1 1-6/10 2-1/23-2/104 5 8 12<br>Time in seconds<br>0.1 1 10 100 1000<br>**----- End of picture text -----**<br>
**==> picture [361 x 620] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>400,000<br>a a<br>LPS-RK amp rating<br>THI<br>100,000<br>IPoee ee| Lales 600A<br>400A<br>|| FT-FTA<br>200A<br>100A<br>60A<br>10,000<br>30A<br>\\\ Z Se arr<br>eetemeei east$f efeeeeet<br>A<br>8<br>\ ——<br>1000<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>ACTAALLENALLEN A-B = Asymmetrical available peak (2.3 x Sym. RMS Amps)<br>LPS-RK amp rating LPS Current limitation curves<br>ET B<br>400,000<br>eeae<br>rrWi<br>100,000<br>te oe |<br>[AE] TAI<br>600A<br>400A<br>een2 ee 200A<br>100A<br>60A<br>10,000<br>VUTATSa a|ee| | aree 15A30A<br>TL A Lo<br>a 1000 eetae<br> eect eat<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>A-B = Asymmetrical available peak (2.3 x Sym. RMS Amps)<br>Instantaneous peak let-through current in amps<br>1000 10,000 100,000 200,000<br>100 1000<br>Instantaneous peak let-through current in amps<br>1000 10,000 100,000 300,000<br>**----- End of picture text -----**<br>
Data sheet no. LPN-RK 1003 (up to 60 A), 1007 (70-600 A) LPS-RK 1001 (up to 60 A), 1002 (70-600 A)
Eaton.com/bussmannseries
1-26
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
## **Low voltage, branch circuit fuses — 1**
## KTN-R (250 V) and KTS-R (600 V) Class RK1 Limitron fast-acting fuses
Fast-acting, current-limiting Class RK1 fuses. For superior electrical protection, Eaton recommends upgrading KTN-R fuse applications to Bussmann series Low-Peak LPN-RK 250 V or LPS-RK 600 V fuses, see pages 1-24 to 1-26. For dimensions, see page 1-3.
## Ratings
## • Volts
- KTN-R −250 Vac (or less) −250 Vdc (70-350 A)
- KTS-R 600 Vac (or less)
- Amps 1-600 A
- IR
- 200 kA RMS Sym.
- 100 kA Vdc (KTN-R)
## Agency information
- KTN-R
- UL Listed, Std 248-12, Class RK1, Guide JDDZ, File E4273
- CSA Certified, Class 1422-02, File 53787
- KTS-R
- UL Listed, Std 248-12, Class RK1, Guide JDDZ, File E54273
|Catalog no. (amps)|||||||
|---|---|---|---|---|---|---|
|250 V KTN-R<br>KTN-R-1<br>KTN-R-2<br>KTN-R-3<br>KTN-R-4<br>KTN-R-5|KTN-R-15<br>KTN-R-20<br>KTN-R-25<br>KTN-R-30<br>KTN-R-35|KTN-R-70<br>KTN-R-75<br>KTN-R-80<br>KTN-R-90<br>KTN-R-100|KTN-R-200<br>KTN-R-225<br>KTN-R-250<br>KTN-R-300<br>KTN-R-350||Low voltage,|branch circuit fuses|
|KTN-R-6|KTN-R-40|KTN-R-110|KTN-R-400||||
|KTN-R-8|KTN-R-45|KTN-R-125|KTN-R-450||||
|KTN-R-10<br>~~OO~~|KTN-R-50<br>~~OO~~|KTN-R-150<br>~~OO~~|KTN-R-500<br>~~OO~~|~~OO~~|||
|KTN-R-12<br>600 V KTS-R<br>~~OO~~|KTN-R-60<br>~~OO~~|KTN-R-175<br>~~OO~~|KTN-R-600<br>~~OO~~|~~OO~~|||
||||||||
|KTS-R-1|KTS-R-12|KTS-R-70|KTS-R-225||||
|KTS-R-2|KTS-R-15|KTS-R-75|KTS-R-250||||
|KTS-R-3<br>KTS-R-4|KTS-R-30<br>KTS-R-35|KTS-R-80<br>KTS-R-90|KTS-R-300<br>KTS-R-350||||
|KTS-R-5|KTS-R-40|KTS-R-125|KTS-R-400||||
|KTS-R-6|KTS-R-45|KTS-R-150|KTS-R-450||||
|KTS-R-8|KTS-R-50|KTS-R-175|||||
|KTS-R-10|KTS-R-60|KTS-R-200|||||
|KTS-R-20|KTS-R-100|KTS-R-500|||||
|KTS-R-25|KTS-R-110|KTS-R-600|||||
Recommended blocks for Class RK1 fuses, see page 1-2.
- CSA Certified, C22.2 No 248.12, Class 1422-02, File 53787
> • CE
## Features
- Current limitation for non-inductive circuits provides Class RK1 current-limiting response to maximum ground fault and shortcircuit conditions
- 200 kA interrupting rating provides high ratings at all circuit locations
- Economical protection for high-fault current circuits
## Typical applications
- Panelboards
Data sheet no. 1043 (KTN-R), 1044 (KTS-R)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-27
**1 — Low voltage, branch circuit fuses**
KTN-R Time-current characteristics — average melt
KTN-R Current limitation curves
KTS-R Time-current characteristics — average melt
**==> picture [240 x 659] intentionally omitted <==**
**----- Start of picture text -----**<br>
Amp rating<br>300<br>CC<br>100<br>Unoo<br>Arret<br>CINE er<br>10<br>AVIA<br>sit on a a matt<br>1 TTA CETTE<br>EVAN AG<br>0.1 Hit wR<br>TAMA<br>SiriaasECCAAATaes s iae tae<br>CHINN CA<br>0.01<br>NN<br> Current in amps<br>KTS-R Current limitation curves<br>B<br>400,000<br>100,000 errr ep<br>es aes 600A<br>400A<br>200A<br>100A<br>10,000 60A<br>30A<br>A<br>Seaeeeeetta<br>cere<br>1000<br>crTHM| UIE<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>A-B = Asymmetrical available peak (2.3 x Sym. RMS Amps)<br>30 60 100 200 400 600<br>Time in seconds<br>40 100 1000 10,000<br>Instantaneous peak let-through current in amps<br>1000 10,000 100,000 200,000<br>**----- End of picture text -----**<br>
## KTS-R Current limitation curves
Data sheet no. 1043 (KTN-R), 1044 (KTS-R)
Eaton.com/bussmannseries
1-28 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
Catalog no. (amps) ~~_[Lee]~~
## FRN-R (250 V) and FRS-R (600 V) Class RK5 Fusetron™ energy efficient, dual-element, time-delay fuses
250 V FRN-R
|FRN-R (250 V) and FRS-R (600 V) Class RK5<br>Fusetron™ energy efficient, dual-element,<br>~~_[Lee]~~|Catalog no. (amps)<br>250 V FRN-R<br>~~_[Lee]~~|~~[Lee]~~|~~[Lee]~~|~~[Lee]~~|
|---|---|---|---|---|
|Dual-element, time-delay Class RK5 fuses. FRN-R — 10 seconds<br>(minimum) at 500% rated amps (8 seconds for 0-30 A sizes). FRS-R<br>— 10 seconds (minimum) at 500% rated amps. FRN-R and FRS-R<br>available with optional indication on select ratings (see catalog<br>numbers table). For superior electrical protection, Eaton recommends<br>upgrading to Bussmann series Low-Peak LPN-RK (250 V) or LPS-RK<br>(600 V) fuses, see pages 1-24 to 1-26. For dimensions, see page 1-3.|FRN-R-1/10<br>FRN-R-1/8<br>FRN-R-15/100<br>FRN-R-2/10<br>FRN-R-1/4<br>FRN-R-3/10<br>FRN-R-4/10|FRN-R-2<br>FRN-R-2-1/4<br>FRN-R-2-1/2<br>FRN-R-2-8/10<br>FRN-R-3<br>FRN-R-3-2/10<br>FRN-R-3-1/2|FRN-R-10*<br>FRN-R-12*<br>FRN-R-15*<br>FRN-R-17-1/2*<br>FRN-R-20*<br>FRN-R-25*<br>FRN-R-30*|FRN-R-100<br>FRN-R-110<br>FRN-R-125<br>FRN-R-150<br>FRN-R-175<br>FRN-R-200<br>FRN-R-225|
|ig|FRN-R-1/2<br>FRN-R-4<br>FRN-R-35*<br>FRN-R-250<br>FRN-R-6/10<br>FRN-R-4-1/2<br>FRN-R-40*<br>FRN-R-300<br>FRN-R-8/10<br>FRN-R-5<br>FRN-R-45*<br>FRN-R-350<br> ~~oo~~||||
||FRN-R-1|FRN-R-5-6/10|FRN-R-50*|FRN-R-400|
|aaa.|FRN-R-1-1/8<br>FRN-R-1-1/4<br>FRN-R-1-4/10<br>~~°°~~<br>~~°°~~|FRN-R-6<br>FRN-R-6-1/4<br>FRN-R-7<br>~~°°~~|FRN-R-60*<br>FRN-R-70<br>FRN-R-75<br>~~°°~~|FRN-R-450<br>FRN-R-500<br>FRN-R-600<br>~~°°~~|
||FRN-R-1-1/2|FRN-R-7-1/2|FRN-R-80||
||FRN-R-1-6/10|FRN-R-8*|FRN-R-85||
||FRN-R-1-8/10|FRN-R-9*|FRN-R-90||
||600 V FRS-R||||
||FRS-R-1/10|FRS-R-2|FRS-R-10*|FRS-R-100|
||FRS-R-1/8|FRS-R-2-1/4|FRS-R-12*|FRS-R-110|
||FRS-R-15/100|FRS-R-2-1/2|FRS-R-15*|FRS-R-125|
||FRS-R-2/10|FRS-R-2-8/10|FRS-R-17-1/2*|FRS-R-150|
||FRS-R-1/4|FRS-R-3|FRS-R-20*|FRS-R-175|
||FRS-R-3/10|FRS-R-3-2/10|FRS-R-25*|FRS-R-200|
||FRS-R-4/10|FRS-R-3-1/2|FRS-R-30*|FRS-R-225|
|UL Listed, Std 248-12, Class RK5, Guide JDDZ, File E4273|FRS-R-1/2|FRS-R-4|FRS-R-35*|FRS-R-250|
||FRS-R-6/10|FRS-R-4-1/2|FRS-R-40*|FRS-R-300|
||FRS-R-8/10|FRS-R-5|FRS-R-45*|FRS-R-350|
|UL Listed, Std 248-12, Class RK5, Guide JDDZ, File E4273|FRS-R-1|FRS-R-5-6/10|FRS-R-50*|FRS-R-400|
||FRS-R-1-1/8|FRS-R-6*|FRS-R-60*|FRS-R-450|
||FRS-R-1-1/4|FRS-R-6-1/4*|FRS-R-65|FRS-R-500|
||FRS-R-1-4/10|FRS-R-7*|FRS-R-70|FRS-R-600|
||FRS-R-1-1/2|FRS-R-7-1/2*|FRS-R-75||
|Separate overload and short-circuit elements provide time-delay for|FRS-R-1-6/10|FRS-R-8*|FRS-R-80||
||FRS-R-1-8/10|FRS-R-9*|FRS-R-90||
Dual-element, time-delay Class RK5 fuses. FRN-R — 10 seconds (minimum) at 500% rated amps (8 seconds for 0-30 A sizes). FRS-R — 10 seconds (minimum) at 500% rated amps. FRN-R and FRS-R available with optional indication on select ratings (see catalog numbers table). For superior electrical protection, Eaton recommends upgrading to Bussmann series Low-Peak LPN-RK (250 V) or LPS-RK (600 V) fuses, see pages 1-24 to 1-26. For dimensions, see page 1-3.
## Ratings
- Volts
- FRN-R
- −250 Vac (or less)
- −125 Vdc (1/10-60 A, 110-200 A)
- −250 Vdc (225-600 A)
- FRS-R
- −600 Vac (or less)
- −300 Vdc 1/10-30 A, 65-600 A
- −250 Vdc* 35-60 A
- Amps 1/10-600 A
## • IR
- 200 kA RMS Sym.
- 20 kA DC
- Does not apply to indicating versions.
## Agency information
## • FRN-R
- UL Listed, Std 248-12, Class RK5, Guide JDDZ, File E4273
- CSA Certified, Class 1422-01, File 53787
## • FRS-R
- UL Listed, Std 248-12, Class RK5, Guide JDDZ, File E4273
- CSA Certified, Class 1422-02, File 53787
- CE
## Features
- Separate overload and short-circuit elements provide time-delay for sizing as close as 125% of motor FLA
- 2:1 selective coordination amp ratio (within the Fusetron RK5 fuse family) helps prevent overcurrent events from opening upstream Fusetron fuses
- Available with indication To order, place "ID" at the end of the catalog number. Example: FRN-R-30ID or FRS-R-7ID.
Recommended blocks for Class RK5 fuses, see page 1-2.
- Insulated end caps for 225-600 A (FRN-R) and 65-600 A (FRS-R) fuses reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
## Typical applications
- Power panelboards
- Motor control centers
- Combination starters
- Machinery disconnects
Data sheet no. FRN-R; 1019 (up to 60 A), 1020 (70-600 A) FRS-R 1017 (up to 60 A), 1018 (70-600 A)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-29
**1 — Low voltage, branch circuit fuses**
FRN-R Time-current characteristics — average melt
**==> picture [263 x 649] intentionally omitted <==**
**----- Start of picture text -----**<br>
FRN-R Current limitation curves<br>400,000 B<br>100,000<br>600A<br>400A<br>200A<br>100A<br>60A<br>10,000 30A<br>A<br>1000<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>A-B = Asymmetrical available peak (2.3 x Sym. RMS Amps)<br>8 10 15 30 60 100 200 400 600<br>Instantaneous peak let-through current in amps<br>1000 10,000 100,000 200,000<br>**----- End of picture text -----**<br>
FRS-R Time-current characteristics — average melt
**==> picture [245 x 364] intentionally omitted <==**
FRS-R Current limitation curves
**==> picture [236 x 253] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>400,000<br>100,000<br>600A<br>400A<br>200A<br>100A<br>60A<br>30A<br>10,000<br>15A<br>A<br>1000<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>A-B = Asymmetrical available peak (2.3 x Sym. RMS Amps)<br>Instantaneous peak let-through current in amps<br>1000 10,000 100,000 200,000<br>**----- End of picture text -----**<br>
Data sheet no. FRN-R; 1019 (up to 60 A), 1020 (70-600 A) FRS-R 1017 (up to 60 A), 1018 (70-600 A)
Eaton.com/bussmannseries
1-30
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
## JJN (300 V) and JJS (600 V) Class T Limitron fast-acting fuses
Very fast-acting, current-limiting 300 V (JJN) and 600 V (JJS) Class T fuse. For dimensions, see page 1-4.
## Typical applications
- Large apartment complexes
- Multi-family meter stacks
- VFD line protection
## Ratings
|h||<br> ||&||Catalog no. (amps)||||
|---|---|---|---|---|---|---|---|
|=||||300 V JJN||||
|a,<br>*||a, oo<br>||JJN-1<br>JJN-35<br>JJN-110<br>JJN-400<br>JJN-2<br>JJN-40<br>JJN-125<br>JJN-450<br>JJN-3<br>JJN-45<br>JJN-150<br>JJN-500<br>JJN-6<br>JJN-50<br>JJN-175<br>JJN-600<br> ~~a~~||||
|‘||||JJN-10|JJN-60|JJN-200|JJN-700|
|||||JJN-15|JJN-70|JJN-225|JJN-800|
|||||JJN-20|JJN-80|JJN-250|JJN-1000|
||a|om||JJN-25|JJN-90|JJN-300|JJN-1200|
|||||JJN-30|JJN-100|JJN-350||
||n<br>LiMITRON ||||600 V JJS<br> ~~Pe~~||||
|Se|Se|Se|e|JJS-1<br> ~~a~~|JJS-30<br>~~a~~|JJS-90<br>~~a~~|JJS-250<br>~~a~~|
|||||JJS-2|JJS-35|JJS-100|JJS-300|
|||||JJS-3|JJS-40|JJS-110|JJS-350|
|||||JJS-6|JJS-45|JJS-125|JJS-400|
|UL Listed, Std 248-15, Class T, Guide JDDZ, File E4273, CSA|UL Listed, Std 248-15, Class T, Guide JDDZ, File E4273, CSA|||JJS-10|JJS-50|JJS-150|JJS-450|
|||||JJS-15|JJS-60|JJS-175|JJS-500|
|||||JJS-20|JJS-70|JJS-200|JJS-600|
|||||JJS-25|JJS-80|JJS-225|JJS-800|
- Volts **2011/65/EU**
- JJN −300 Vac (or less)
- −160 Vdc (15-600 A)
- −170 Vdc (601-1200 A)
- JJS 600 Vac (or less)
- Amps
- JJN 1-1200 A
- JJS 1-800 A
- IR
- 200 kA RMS Sym.
- 20 kA DC @ 160 Vdc (JJN)
- 100 kA DC @ 170 Vdc (JJN)
## Agency information
- UL Listed, Std 248-15, Class T, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787, RoHS compliant, CE
## Features
- Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer
Recommended blocks for Class T fuses, see page 1-2.
- Current limitation for non-inductive circuits provides Class T current-limiting response to maximum ground fault and shortcircuit conditions
- 200 kA interrupting rating provides protection for virtually all circuit locations
- Small footprint allows more efficient use of panel space
## Current-limiting effects
## 300 V JJN
|Prosp.<br>S.C.C.|Let-through current (apparent RMS Sym. vs. fuse rating)|Let-through current (apparent RMS Sym. vs. fuse rating)|Let-through current (apparent RMS Sym. vs. fuse rating)|Let-through current (apparent RMS Sym. vs. fuse rating)|through current (apparent RMS Sym. vs. fuse rating)|through current (apparent RMS Sym. vs. fuse rating)|through current (apparent RMS Sym. vs. fuse rating)|||
|---|---|---|---|---|---|---|---|---|---|
|—|15 A|30 A|60 A|100 A|200 A|400 A|600 A|800 A|1200 A|
|500|1000|1000|1000|1000|1000|1000|1000|1000|1000|
|1000|1000|1000|1000|1000|1000|1000|1000|1000|1000|
|5000|1000|1000|1000|1000|2000|3000|5000|5000|5000|
|10,000|1000|1000|1000|2000|2000|4000|6000|7000|9000|
|15,000|1000|1000|1000|2000|3000|4000|6000|9000|10,000|
|20,000|1000|1000|1000|2000|3000|5000|7000|10,000|11,000|
|25,000|1000|1000|2000|2000|3000|5000|7000|10,000|12,000|
|30,000|1000|1000|2000|2000|3000|5000|8000|11,000|13,000|
|35,000|1000|1000|2000|3000|4000|6000|8000|11,000|13,000|
|40,000|1000|1000|2000|3000|4000|6000|9000|11,000|13,000|
|50,000|1000|1000|2000|3000|4000|7000|9000|12,000|15,000|
|60,000|1000|1000|2000|3000|4000|7000|10,000|13,000|16,000|
|70,000|1000|1000|2000|3000|5000|7000|10,000|14,000|17,000|
|80,000|1000|2000|2000|3000|5000|8000|11,000|15,000|17,000|
|90,000|1000|2000|2000|3000|6000|8000|11,000|15,000|18,000|
|100,000|1000|2000|2000|4000|6000|8000|12,000|16,000|19,000|
|150,000|1000|2000|3000|4000|6000|9000|13,000|17,000|22,000|
|200,000|2000|2000|3000|4000|7000|9000|15,000|19,000|23,000|
## 600 V JJS
|Prosp.<br>S.C.C.|Let-through current (apparent RMS Sym. vs. fuse rating)|Let-through current (apparent RMS Sym. vs. fuse rating)|Let-through current (apparent RMS Sym. vs. fuse rating)|Let-through current (apparent RMS Sym. vs. fuse rating)|Let-through current (apparent RMS Sym. vs. fuse rating)|through current (apparent RMS Sym. vs. fuse rating)|||
|---|---|---|---|---|---|---|---|---|
|—|15A|30A|60A|100A|200A|400A|600A|800A|
|500|1000|1000|1000|1000|1000|1000|1000|1000|
|1000|1000|1000|1000|1000|1000|1000|1000|1000|
|5000|1000|1000|1000|2000|3000|4000|5000|5000|
|10,000|1000|1000|1000|2000|3000|6000|8000|9000|
|15,000|1000|1000|2000|3000|4000|7000|10,000|11,000|
|20,000|1000|1000|2000|3000|4000|7000|10,000|12,000|
|25,000|1000|1000|2000|3000|5000|7000|11,000|13,000|
|30,000|1000|1000|2000|3000|5000|8000|12,000|14,000|
|35,000|1000|1000|2000|3000|5000|9000|13,000|15,000|
|40,000|1000|2000|2000|4000|5000|9000|13,000|15,000|
|50,000|1000|2000|2000|4000|6000|10000|14,000|17,000|
|60,000|1000|2000|3000|4000|6000|10000|16,000|18,000|
|70,000|1000|2000|3000|4000|7000|11000|17,000|19,000|
|80,000|1000|2000|3000|4000|7000|11000|17,000|20,000|
|90,000|1000|2000|3000|4000|7000|12000|18,000|21,000|
|100,000|2000|2000|3000|5000|7000|12,000|19,000|22,000|
|150,000|2000|3000|4000|6000|8000|14,000|22,000|25,000|
|200,000|2000|3000|4000|6000|9000|16,000|24,000|28,000|
Data sheet no. 1025 (JJN) and 1029 (JJS)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-31
**1 — Low voltage, branch circuit fuses**
JJN Time-current characteristics — average melt
## JJS Time-current characteristics — average melt
**==> picture [261 x 302] intentionally omitted <==**
**----- Start of picture text -----**<br>
Amp rating<br>300<br>\<br>00 1 en AT OV<br>100<br>LOUING NCO<br>PECTEDYC NCTII VA-CCETTT<br>10 eeOIAOe ee NeeVAAA<br>SSS St<br>ehie<br>om RsOO Ve<br>1<br>GRA<br>SE|<br>0.1<br>ACACIA\T<br>0.01<br>ENTITIESCANT<br>Current in seconds<br>1 3 6 10 15 30 60 100 200 400 500 600<br>Time in seconds<br>1 10 100 1000 10,000<br>**----- End of picture text -----**<br>
JJN Current limitation curves
## JJS Current limitation curves
**==> picture [5 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
B<br>**----- End of picture text -----**<br>
**==> picture [291 x 251] intentionally omitted <==**
**----- Start of picture text -----**<br>
400,000<br>100,000<br>ise |baa 800A<br>600A<br>400A<br>FEE<br>EE A 200A<br>100A<br>10,000 60A<br>CIamZea<br>30A<br>La ; tT TTT eet te ee 15A<br>1000 Bleaign<br>tt ert<br>EZCr<br>200A 7EIT<br>Prospective short-circuit current (Symmetrical RMS Amps)<br>A-B = Asymmetrical available peak (2.3 x Sym. RMS Amps)<br>Instantaneous peak let-through current in amps<br>100 1000 10,000 100,000 200,000<br>**----- End of picture text -----**<br>
Data sheet no. 1025 (JJN) and 1029 (JJS)
Eaton.com/bussmannseries
1-32 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
## W plug fuses
Fast-acting Edison base plug fuse.
## Ratings
## SL rejection base and TL Edison base plug fuses
Time-delay, loaded link Edison (TL) and rejection base (SL) plug fuses.
## Rating
- Volts 125 Vac
- Amps 1/2-12 A
- IR 10 kA RMS Sym.
- Volts 125 Vac
- Amps 15-30 A
- IR 10 kA RMS Sym.
## Agency information
## Agency information
- UL Listed, Std 248-11, Guide JEFV, File E12112, CE
- UL Listed, Std 248-11, Guide JEFV, File E12112, CE
## Features
## Features
- Dependable, fast-acting circuit protection with 10 kA interrupting rating for added safety when applied to existing plug fuse systems and 125 volt single-phase control circuits
## Typical applications
- Replacement fuses for existing systems
- Time-delay loaded link TL Edison base plug fuses pass motor overload starting currents without opening and allow closer sizing to motor load for added protection
- Time-delay loaded link SL fuses provide a rejection feature (when used alone or with Fustat adapters to retrofit Edison base holders) to help prevent overfusing
- For general purpose circuit protection
- Lighting and other non-motor circuits
|Catalog no.* (amps)|Catalog no.* (amps)|||
|---|---|---|---|
|W-1/2|W-2-1/2|W-6|W-10|
|W-1|W-3|W-6-1/2|W-12|
|W-1-8/10|W-4|W-7|W-DUMMY**|
|W-2|W-5|W-8||
- W-15 to W-30 plug fuses obsolete. Replace with either T-(amp) or TL-(amp) Edison base plug fuses.
** Non-conductive dummy base NOT a fuse.
Recommended box cover units for W plug fuses, see page 1-36.
## Typical applications
- Small motor and inductive load circuits with high in-rush current levels
- TL for box cover units to provide small motor overload protection
- SL for applications benefiting from fuse rejection
|Catalog no. (amps)||||
|---|---|---|---|
|Rejection base SL||||
|SL-15|SL-20|SL-25|SL-30|
|Edison base TL||||
|TL-15|TL-20|TL-25|TL-30|
Recommended box cover units for SL and TL plug fuses, see page 1-36. For Fustat™ Edison base adapters for use with SL fuses see page 1-35.
Data sheet no. 1036
Data sheet no. 1033 (SL) and 1035 (TL)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-33
**1 — Low voltage, branch circuit fuses**
## S rejection base and T Edison base plug fuses
Dual-element, time-delay Edison (T) and rejection base (S) plug fuses.
## Rating
- Volts 125 Vac
- Amps
- S 1/4-30 A
- T 3/10-30 A
## P and TC CSA plug fuses
CSA Edison base Type P (P) dual-element fuses and Type D (TC) dual-element, time-delay fuses.
## Ratings
- Volts 125 Vac or less
- Amps 15-30 A
- IR 10 kA
## Agency information
- IR 10 kA RMS Sym.
- P - CSA Certified
## Agency information
- UL Listed, Std 248-11, Type S and T (0 to 6-1/4) Guide JFHR, File E56412 (7 to 30 A) Guide JEFV, File E12112; CSA Certified, Class 1423-01, File 53787, CE
## Features
- T Edison base fuses provide small motor overload protection when used with box cover units
- S rejection base fuses provide a rejection feature (when used alone or with Fustat adapters to retrofit Edison base holders) to prevent overfusing of branch circuits
## Typical applications
- S for residential load centers
- T for box cover units to provide small motor overload protection
- Applications benefiting from fuse rejection to help prevent overfusing (S only)
|Catalog no. (amps)||||
|---|---|---|---|
|Rejection base S||||
|S-1/4|S-1-4/10|S-3-1/2|S-20|
|S-3/10|S-1-6/10|S-4|S-25|
|S-4/10|S-1-8/10|S-7|S-30|
|S-1/2|S-2|S-8||
|S-6/10|S-2-1/4|S-9||
|S-8/10|S-2-1/2|S-10||
|S-1|S-2-8/10|S-12||
|S-1-1/8|S-3|S-14||
|S-1-1/4|S-3-2/10|S-15||
|Edison base T||||
|T-3/10|T-1-6/10|T-4|T-10|
|T-4/10|T-1-8/10|T-4-1/2|T-12|
|T-1/2|T-2|T-5|T-14|
|T-6/10|T-2-1/4|T-5-6/10|T-15|
|T-8/10|T-2-1/2|T-6|T-20|
|T-1|T-2-8/10|T-6-1/4|T-25|
|T-1-1/8|T-3|T-7|T-30|
|T-1-1/4|T-3-2/10|T-8||
|T-1-4/10|T-3-1/2|T-9||
- TC - CSA Certified, Class 1423-01, File 53787
## Features
- P
- "P" rating addresses the need of Canadian applications
- Non-time delay protects non-inductive loads
- TC
- "D" rating addresses the need of Canadian applications
- Heavy duty TC fuses are industrial strength products, featuring dual-element construction
- This spring loaded design provides superior short-circuit and overload protection
- The TC fuses have more time-delay than the medium duty fuses in order to better protect industrial motors and residential circuits
## Typical applications
- P for non-inductive loads, residential load centers
- TC for box cover units to provide small motor overload protection
|Catalog no. (amps)||||
|---|---|---|---|
|Type P||||
|P-15|P-20|P-25|P-30|
|Type D||||
|TC-15|TC-20|TC-25|TC-30|
Recommended box cover units for P and TC plug fuses, see page 1-36.
Recommended box cover units for S and T plug fuses, see page 1-36. For Fustat Edison base adapters for use with SL fuses see page 1-35.
Data sheet no. 1032 (S) and 1034 (T)
Data sheet no. 1039 (TC)
Eaton.com/bussmannseries
1-34
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage, branch circuit fuses — 1**
## MB Edison base circuit breakers
Edison base manual reset circuit breakers.
## Ratings
## SA Fustat fuse adapters
Adapters for using Type S and SL rejection base fuses in Edison base fuse sockets. Amp rating rejection feature helps prevent overfusing.
## Ratings
- Volts 125 Vac only
- Amps 15 and 20 A
- IR 10 kA RMS Sym.
## Agency information
- UL Listed, File E14942
## Features
- Edison base circuit breakers fit standard Edison base fuse sockets to provide resettable overcurrent protection (correct cause of overcurrent event before resetting)
- Volts 125 Vac
- Amps 1-30 A
## Agency information
- UL Listed, File E12853, CSA Certified, Class 6225-01, File 47235
## Features
- Fustat adapters screw into the "Edison" thread fuse sockets to easy retrofit existing fuse installations to rejection base fuses
- Available in various amp ratings to cover a wide range of rating requirements to help prevent overfusing
## Typical applications*
## Typical applications
- Replacing Edison base plug fuses in residential fuse panels
- Plug fuse installations where it is desirable to restrict fuse amp ratings and help prevent overfusing
|Catalog no.* (amps)||
|---|---|
|MB-15|MB-20|
- Not for use in box cover units or for inductive loads.
|Catalog no.|Accepts S fuses|Accepts SL fuses|
|---|---|---|
|SA-1*|S-1 or smaller|—|
|SA-1-1/4*|S-1-1/4 or smaller|—|
|SA-1-6/10*|S-1-6/10 or smaller|—|
|SA-2*|S-2 or S-1-8/10|—|
|SA-2-1/2*|S-2-1/2 to S-1-8/10|—|
|SA-3-2/10*|S-3-2/10 to S-1-8/10|—|
|SA-4*|S-4 to S-3-1/2|—|
|SA-5*|S-5 to S-3-1/2|—|
|SA-6-1/4*|S-6-1/4 to S-3-1/2|—|
|SA-8*|S-8 to S-7|—|
|SA-10*|S-10 to S-7|—|
|SA-15**|S-15 to S-7|SL-15|
|SA-20**|S-20|SL-20|
|SA-30**|S-30 to S-25|SL-52, SL-30|
- Single motor circuits - both running and short-circuit protection.
- ** Branch circuits.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
1-35
**1 — Low voltage, branch circuit fuses**
## Box cover units for Edison base plug fuses
SOU, SRU, SSU, SOW, SRW, SSW, SOX, SRX, SOY, SRY, SSY, SSY-RL, STY, SCY, SOY-B and SSN
Box cover units for standard electrical boxes provide supplemental fuse protection for small motor circuits and other loads requiring overcurrent protection below that of the branch circuit overcurrent protective device. Versions are available for a fused outlet, switch or plain circuit that fit standard sized electrical boxes. See catalog numbers for available configurations by box type.
Use with SA adaptors and S or SL Type fuses may prevent fuse cover from closing. Not recommended for use with MB-15 Edison base circuit breaker.
**==> picture [212 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
SOU SRU SSU SSN<br>**----- End of picture text -----**<br>
## Ratings
- Volts 125 V
- Amps 15 A
## Agency information
- UL Listed, Guide JAMZ, File IE6491
- CSA Class 6225-01, File 47235
## Features
- A low-cost method of controlling and protecting small motors when used with Bussmann series Type T dual-element fuses
- Low-cost supplemental protection and disconnection of 125 V or less, single-phase circuits
## Typical applications
- Fractional horsepower, 125 volt single-phase motor circuits
**==> picture [248 x 196] intentionally omitted <==**
**----- Start of picture text -----**<br>
2-1/4” handy box units 4” square box units<br>es<br>SOU SRU SSU SOY SRY SSY<br>2-3/4” switch box units<br>mm<br>mi) |s) le<br>SOW SRW SSW SSY-RL SOY-B STY<br>4” octagon box units<br>g<br>) Y) ey<br>SOX SRX SCY<br>**----- End of picture text -----**<br>
- General 125 volt supplemental circuits
|Catalog no.|Catalog no.<br>Box type|Fuse<br>sockets|Switch<br>control1|Pilot<br>light2|Max motor<br>size (Hp)|Description|Agency<br>information|
|---|---|---|---|---|---|---|---|
|SOU||1|||3/4|Fuse receptacle only (no switch or outlet)|UL, CSA|
|SRU|2-1/4" Handy|1|||1/2|Fused outlet|UL|
|SSU||1|X||1/2|Fused switch|UL, CSA|
|SOW||1|||3/4|Fuse receptacle only (no switch or outlet)|UL, CSA|
|SRW|2-3/4" Switch|1|||1/2|Fused outlet|UL|
|SSW||1|X||1/2|Fused switch|UL, CSA|
|SOX<br>SRX|4" Octagon|1<br>1|||3/4<br>1/2|Fuse receptacle only (no switch or outlet)<br>Fused outlet|UL, CSA<br>UL|
|SOY||1|||3/4|Fuse receptacle only (no switch or outlet)|UL, CSA|
|SRY||1|||1/2|Fused outlet|UL|
|SSY||1|X||1/2|Fused switch|UL, CSA|
|SSY-RL|4" Square|1|X|X|1/2|Fused switch/outlet with pilot light|—|
|STY3||2|X||1/2|Fused double pole switch, dual fuse receptacles|UL|
|SCY4||2|||1/2|Dual fused switches|UL|
|SOY-B||2|||3/4|Dual fuse receptacles only (no switch or outlet)|UL|
|SSN|Single gang|1|X||1/2|Weatherproof fused switch|UL|
- 1 Switch turns power to fused load OFF or ON.
- 2 Pilot light indicates power to load (dark when switch OFF or fuse open).
- 3 Double pole switch opens both sides of circuit.
- 4 Can be used for two separate motors with common switch or a single motor (3/4 Hp, 250 Vac max).
Data sheet no. 1129
Eaton.com/bussmannseries
1-36
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage supplemental fuses — 2**
## Contents
Bussmann series - Fuses Made Simple[TM] Control Circuits
||Description<br>Fuse holder and block selectionguide|Description<br>Fuse holder and block selectionguide|Section<br>page<br>2|
|---|---|---|---|
||Product<br>Limiters|Catalogsymbol||
||Cable limiters<br>Welder limiters<br>Bolt-on<br>Supplemental fuses|K(600 V)<br>UH(250 V)<br>64000 (600 V)<br>68000(600 V)<br>ANN(125 V veryfast-acting)<br>ANL(80 V non time-delay)<br>4164 and 4164-FR blocks|3<br>4|
||13/32" x 1-1/2" fast-acting|BAF(250 V)<br>KTK(600 V)|5|
||13/32" x 1-1/2" time-delay<br>13/32" x 1-3/8" fast-acting|KLM(600 V)<br>FNM(250 V)<br>FNQ(500 V)<br>BBS(600 V)|6<br>7|
|||GBA(125 V)||
|||GLD(125 V)|8|
||Pin indication and actuator|MIC(250 V fast-acting)<br>FNA 250 V time-delay)||
|||MIS(600 V)|9|
|KAZ(600 V)<br>In-line fuses<br>size rejecting<br>GLQ<br>GMQ<br>size rejectingholder<br>HLQ<br>~~Sa~~<br>~~a~~<br>~~S$. $$~~|||10|
||Non size-rejecting fuses and<br>holders|GLR<br>GMF<br>GRF|11|
||Non size-rejecting fuse<br>holders|HLR<br>HLR-2A||
||Blade fuses and holders|||
|||ATR micro||
||Fuses|ATM<br>ATM-_ID<br>ATM-LP<br>ATC<br>ATC-_ID<br>MAX<br>MAX-_ID|12<br>13|
|||HH2 (ATR)||
||In-line fuse holders|ATC-FHID (ATC)<br>HHC (ATC)<br>HHD (ATC)<br>HHF (ATC)<br>HHG (ATC)<br>HHR (ATC)<br>HHS (ATC)||
|||ATM-FHID (ATM)<br>HHL (ATM)<br>HHM (ATM)<br>HHU (ATM)|14|
|||HHX (MAX))<br>MAX-FHID (MAX))||
||PCB fuseclips|||
||ATC|1A5600<br>1A5780||
||ATM|1A5778<br>1A5779||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
2-1
**2 — Low voltage supplemental fuses**
## Fuse holder and block selection guide
Catalog pages for the blocks and holders are denoted parenthetically "()" next to their catalog symbol.
**==> picture [536 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse Catalog symbol Blocks DIN-Rail holders Panel mount holders In-line holders PCB fuseclips<br>**----- End of picture text -----**<br>
|Cable limiters|K_<br>—<br>—<br>—<br>—<br>—|
|---|---|
||UH_<br>—<br>—<br>—<br>—<br>—|
|Welder limiters|64000<br>68000<br>RM60_ (8-21)<br>—<br>—<br>—<br>—|
|Bolt-on limiters|ANN<br>ANL<br>4164 (2-4)<br>4164-FR (2-4)<br>—<br>—<br>—<br>—|
|13/32" x 1-1/2"<br>supplemental<br>fuses|BAF<br>FNM<br>FNQ<br>KLM<br>KTK<br>BMM603_ (8-6)<br>3743 (8-14)<br>4421 (8-14)<br>4515 (8-14)<br>CCP2-_ (11-2)<br>OPM-1038_ (8-12)<br>OPM-NG_ (8-13)<br>CHM (8-8)<br>NDNF1-WH (8-11)<br>CCPLP††(30 A) (11-32)<br>HPC-D (8-43)<br>HPD (8-44)<br>HPF (8-43)<br>HPG (8-44)<br>HPM (8-44)<br>HPM-D (8-44)<br>HPS2 (8-45)<br>HPS (8-45)<br>HEB (8-51)<br>HEX (8-53)<br>1A3400_ (3-16)<br>5960 (3-16)|
|13/32" x 1-3/8"<br>supplemental<br>fuses|BBS<br>BMM603_ (8-6)<br>—<br>HPS-L (8-45)<br>HEH (8-49)<br>1A3400_ (3-16)<br>5960 (3-16)|
|Pin indication<br>fuses and actuator|GBA<br>GLD<br>—<br>—<br>HLD (8-43)<br>—<br>1A1119 (3-15)<br>1A1120 (3-15)<br>1A1907 (3-15)<br>1A3398 (3-15)<br>1A4533 (3-15)<br>1A4534 (3-15)<br>5681 (3-16)<br>5682 (3-16)|
||MIC<br>FNA<br>BMM603_ (8-6)<br>3839†<br>—<br>HPF-C (8-43)<br>—<br>1A3400_ (3-16)<br>5960 (3-16)|
||MIS fuse<br>KAZ actuator<br>2778†<br>2837†<br>2838†<br>—<br>—<br>—<br>1A3400_ (3-16)<br>5960 (3-16)|
|In-line size<br>rejecting fuses|GLQ<br>GMQ<br>—<br>—<br>—<br>HLQ (2-10)<br>—|
|In-line non-<br>rejecting fuses|GLR<br>GMF<br>GRF<br>—<br>—<br>—<br>HLR (2-11)<br>HLR-2A (2-11)<br>—|
|Automotive blade-<br>type fuses|ATC<br>ATC-_ID<br>FB_-ATC*<br>15600*<br>—<br>—<br>ATC-FHID (2-14)<br>HHC (2-14)<br>HHD (2-14)<br>HHF (2-14)<br>HHG (2-14)<br>HHR (2-14)<br>HHS (2-14)<br>1A5600 (2-14)<br>1A5780 (2-14)|
||ATM<br>ATM-_ID<br>FB_-ATM*<br>RTMF-_*<br>—<br>—<br>ATM-FHID (2-14)<br>HHL (2-14)<br>HHM (2-14)<br>HHU (2-14)<br>1A5778 (2-14)<br>1A5779 (2-14)|
||ATM-LP<br>FB_-ATM*<br>RTMF-_*<br>—<br>—<br>HHV (2-14)<br>—|
||ATR micro<br>FB_-ATR*<br>—<br>—<br>HH2 (2-14)<br>—|
||MAX<br>MAX-_ID<br>HHX (2-14)<br>MAX-FHID (2-14)|
- Not shown in this catalog, for details and available configurations, see Automotive and Home center catalog no. 5084.
- Not shown in this catalog, see data sheet for details.
- †† UL 508 Listed disconnect switch, available in 1-, 2- and 3-pole versions.
Eaton.com/bussmannseries
2-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage supplemental fuses — 2**
## K 600 V cable limiters
Cable limiters for protecting 600 V low voltage distribution and service entrance cables against short-circuit currents.
## Ratings
- Volts 600 Vac
- IR 200 kA RMS Sym. @ 600 Vac
## UH 250 V cable limiters
Cable limiters for protecting 250 V low voltage distribution and service entrance cables used in residential applications against shortcircuit currents.
## Ratings
- Volts Up to 250 Vac
- IR 100 kA RMS Sym.
Agency information
- UL Listed, File E90818, 600 Vac, 200 kA IR on catalog numbers CDA-W, CDB-W, KCD, KCJ, KCM, KCM-B, KCR, KDD, KDF, KDJ, KDM, KDP, KDR, KDU, KEW, KFM, KFT, KHF, KHJ, KHM, KHR
## Features
- Sizes and ratings available to meet many applications
**==> picture [246 x 353] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Cable size|Cable size|
|Catalog no.|(AWG)|Catalog no.|(AWG)|
|*Tubular terminals|
|KCY|4|KCH|250 kcmil|
|KCZ|3|KCJ|[1, 2]|350 kcmil|
|KCA|2|KCM|[1, 2, 3]|500 kcmil|
|KCB|1|KCV|600 kcmil|
|KCC|1/0|KCR|[1, 2]|750 kcmil|
|KCD|[1, 2]|2/0|CDA-W|[1, 4]|750 kcmil|
|KCE|3/0|KCS|1000 kcmil|
|KCF|4/0|
|*Tubular and offset bolt-type terminals|
|KQV|12|KDE|3/0|
|KQT|10|KDF|[1]|4/0|
|KFZ|8|KDH|250 kcmil|
|KIG|6|KDJ|[1, 3]|350 kcmil|
|KDY|4|KDM|[1, 3]|500 kcmil|
|KDA|2|KDU|[1]|600 kcmil|
|KDB|1|KDR|[1, 2]|750 kcmil|
|KDC|1/0|CDB-W|[1, 4]|750 kcmil|
|KDD|[1]|2/0|
|*Compression connector rod and tubular terminals|
|KEX|4/0|KQO|350 kcmil|
|KFH-A|250 kcmil|KDT|500 kcmil|
|**Center bolt-type and off-set bolt-type terminals|
|KPF|4/0|KDP|[1]|500 kcmil|
|KFT|[1]|250 kcmil|KFM|[1]|750 kcmil|
|KEW|[1]|350 kcmil|
|Center bolt-type and tubular terminals|
|KHF|[1]|4/0|KHM|[1]|500 kcmil|
|KHJ|[1]|350 kcmil|KHR|[1]|750 kcmil|
**----- End of picture text -----**<br>
* Copper conductors only.
Terminals and conductors
- Center bolt-to-offset bolt terminals, Cu or Al conductors
- Cu or Al conductors are permitted per the listed cable size. Select the catalog number for the conductor size. See data sheet 1042 for dimensions.
**==> picture [247 x 62] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Catalog no.|Cu cable size (AWG)|Al cable size (AWG)|
|UHA|3/0|4/0|
|UHJ-M|3/0|250 kcmil|
|UHJ-T|350 kcmil|500 kcmil|
|UHJ-W|600 kcmil|800 kcmil|
**----- End of picture text -----**<br>
Data sheet no. 1042
## 64000 and 68000 600 V welder limiters
Limiters for use on welder circuits. Note: welder limiters have special characteristics and are not suitable for use on other circuit types.
## Ratings
- Volts 600 Vac (or less)
- IR 200 kA RMS Sym.
## Features
- Current-limiting devices designed specially for use only on welder circuits
- Time-current characteristics are designed to hold on the intermittent overloading encountered in welder operation, while providing short-circuit protection to the circuit and equipment
**==> picture [248 x 62] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Catalog no.|Fuse holder type|Nominal amp rating|
|68300|Class H|300|
|68600|Class H|600|
|64200|Class J|200|
|64300|Class J|300|
**----- End of picture text -----**<br>
- ** Copper or aluminum conductors.
- 1 UL Listed (File E90818), 600 Vac, 200 kA I.R.
Recommended fuse blocks, see page 2-2.
- 2 Available with shrink tube “_V” suffix.
- 3 Available with molded rubber boots.
- 4 Aluminum conductor only.
## Accessory boots (order separately)
**==> picture [245 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Limiter|Boot catalog no.|Limiter|Boot catalog no.|
|KCM|BOOT-KCM|KDM|BOOT-KDM|
**----- End of picture text -----**<br>
Recommended Thomas and Betts crimp tool TBM-14M with die 15506 KDM/15515 KDR for installation.
Data sheet no. 1045
Data sheet no. 1042
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
2-3
## **2 — Low voltage supplemental fuses**
## ANL/ANN limiters
Circuit limiters typically used in fork lifts, marine, aviation and battery charging systems. ANL limiters are fast-acting and ANN limiters are very fast-acting. Both ANL and ANN limiters measure 7/8" x 3-3/16" (22x81mm) with a depth that varies by amp rating.
## Ratings
- Volts
- ANL 80 Vdc
- ANN 125 Vac, 80 Vdc
- Amps
- ANL 35-750 A
**==> picture [70 x 76] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fast-acting ANL<br>Tr ae<br>Boe O<br>Very fast-acting ANN<br>**----- End of picture text -----**<br>
## 4164 and 4164-FR limiter blocks
Limiter fuse blocks for ANL and ANN. 4164 is furnished with nylon inserted locknuts and 4164-FR is furnished with standard hex nuts.
**==> picture [28 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
4164<br>4164-FR<br>**----- End of picture text -----**<br>
## Dimensions
- L 3.38" x W 0.95" x H 1.62"
- Studs center-to-center 2.43"
## Ratings
- Volts 125 Vac, 80 Vdc, 32 Vdc (self certified)
- Amps 10-800 A
- Poles single, stud terminal
- ANN 10-800 A
Data sheet no. 2133
## • IR
- ANL 2700 A @ 80 Vdc
- ANN 2500 A @ 125 Vac, 2700 A @ 80 Vdc
## Agency information
- ANL: UL Recognized, CSA Certified, 35-750 A @ 80 Vdc, IR 2700 A, Guide JFHR2, File E56412, Class 1422-30, File 53787, SAE J1171
- ANN: UL Recognized, CSA Certified 35-400 A @ 125 Vac, IR 2500 A and 500 A @ 80 Vdc, IR 2700 A, Guide JFHR2, File E56412, Class 1422-30, File 53787, CE for 35-400 A
|Catalog no. (amps)||||
|---|---|---|---|
|Fast-acting ANL||||
|ANL-35|ANL-125|ANL-250|ANL-500|
|ANL-40|ANL-130|ANL-275|ANL-600|
|ANL-50|ANL-150|ANL-300|ANL-675|
|ANL-60|ANL-175|ANL-325|ANL-750|
|ANL-80|ANL-200|ANL-350||
|ANL-100|ANL-225|ANL-400||
|Very fast-acting ANN||||
|ANN-10|ANN-90|ANN-225|ANN-400|
|ANN-35|ANN-100|ANN-250|ANN-500|
|ANN-40|ANN-125|ANN-275|ANN-600|
|ANN-50|ANN-150|ANN-300|ANN-700|
|ANN-60|ANN-175|ANN-325|ANN-800|
|ANN-80|ANN-200|ANN-350||
## Features
- Fast-acting sizing for inductive circuits (ANL)
- Very fast-acting circuit protection (ANN)
- Element viewing window shows limiter status at a glance
Data sheet no. 2023 (ANN), 2024 (ANL)
Eaton.com/bussmannseries
2-4 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage supplemental fuses — 2**
## BAF fast-acting 13/32" x 1-1/2" supplemental fuse
Fast-acting, supplemental fuse. Green color code (250 Vac max). For superior protection, Eaton recommends upgrading to Bussmann series Low-Peak Class CC fuses. See data sheet no. 1023.
## Ratings
|Ratings|||||
|---|---|---|---|---|
|Fuse amp<br>range<br>1/4 to 1<br>1-1/2 to 2-1/2|IR at system voltage<br>250 Vac<br>125 Vac<br>35 A<br>10 kA<br>100 A<br>10 kA||Agency information<br>UL<br>—<br>—|Agency information<br>CSA<br>X<br>X|
|3|100 A|10 kA|X|X|
|4 to 10|200 A|10 kA|X|X|
|12 to 15|750 A|10 kA|X|X|
|20 to 30|200 A|10 kA|—|—|
## Agency information
- UL Listed, Std. 248-14, 250 Vac (3 to 15 A) Guide JDYX, File E19180, CSA Certified, 250 Vac (1/4 to 15 A) Class 1422-01, File 53787
|Catalog no. (amps)||||
|---|---|---|---|
|BAF-1/4|BAF-1-8/10|BAF-6|BAF-12|
|BAF-1/2|BAF-2|BAF-6-1/4|BAF-15|
|BAF-6/10|BAF-2-1/2|BAF-7|BAF-20|
|BAF-8/10|BAF-3|BAF-8|BAF-25|
|BAF-1|BAF-4|BAF-9|BAF-30|
|BAF-1-1/2|BAF-5|BAF-10||
## Features
## KTK fast-acting 13/32" x 1-1/2"supplemental fuse
Fast-acting supplemental fuse. Black color code (600 Vac max). For superior protection, Eaton **2011/65/EU** recommends upgrading to Bussmann series Low-Peak Class CC fuses. See data sheet no. 1023.
## Ratings
|Fuse amp<br>range<br>1/10 to 30|IR at rated voltage<br>600 Vac<br>100 kA|Agency information<br>UL<br>X|Agency information<br>CSA<br>X|
|---|---|---|---|
## Agency information
- UL Listed, Std. 248-14, Guide JDYX, File E19180, CSA Certified, C22.2 No. 248.14, Class 1422-01, File 53787, HRC-MISC, RoHS compliant, CE
|Catalog no. (amps)<br>KTK-1/10|KTK-3/4|KTK-4|KTK-12|
|---|---|---|---|
|KTK-1/8|KTK-1|KTK-5|KTK-15|
|KTK-2/10|KTK-1-1/4|KTK-6|KTK-20|
|KTK-1/4|KTK-1-1/2|KTK-7|KTK-25|
|KTK-3/10|KTK-2|KTK-7-1/2|KTK-30|
|KTK-4/10|KTK-2-1/2|KTK-8||
|KTK-1/2|KTK-3|KTK-9||
|KTK-6/10|KTK-3-1/2|KTK-10||
## Features
- Black color code for 600 Vac rating
- Fast-acting for resistive loads
- Melamine tube construction with nickel-plated bronze endcaps
- Green color code for maximum 250 Vac rating
## Typical applications
- Fiber tube construction with nickel-plated brass endcaps
## Typical applications
- Control circuits
- Lighting circuit protection
- General purpose circuits
- Lighting circuit protection
- Meter circuits
- Meter circuits
Recommended blocks and holders for 13/32" x 1-1/2" fuses, see page 2-2.
Recommended blocks and holders for 13/32" x 1-1/2" fuses, see page 2-2.
Data sheet no. 2011 (0-30)
Data sheet no. 1011
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
2-5
**2 — Low voltage supplemental fuses** ~~I~~ 1C, a
KLM fast-acting 13/32" x 1-1/2" supplemental fuse
## FNM time-delay 13/32" x 1-1/2" supplemental fuse
Fast-acting supplemental fuse. Color code black (600 Vac/dc max). For superior protection, Eaton recommends upgrading to Bussmann series Low-Peak Class CC fuses. See data sheet no. 1023. For protecting PV systems, use PVM 10x30mm PV fuses. See data sheet no. 10121.
Time-delay supplemental fuse. Color code green (250 Vac max). **2011/65/EU** For superior protection, Eaton recommends upgrading to Bussmann series Low-Peak Class CC fuses. See data sheet no. 1023.
**==> picture [23 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
Ratings
Ratings IR at rated voltage Agency information Fuse amp ~~—~~ range 600 Vac 600 Vdc UL CSA 1/10 to 30 100 kA 50 kA X X Electrical characteristics % of amp rating Opening time ~~ee~~ 110% 4 hours minimum 135% AC opens within 1 hour
|Fuse amp range<br>IR at system voltage<br>Agency information<br>250 Vac<br>125 Vac<br>UL<br>CSA<br>1/10 to 1<br>35 A<br>10 kA<br>X<br>X<br>1-1/8 to 3-1/2<br>100 A<br>10 kA<br>X<br>X<br>~~ee~~<br>~~CCC~~|
|---|
|4 to 10<br>200 A<br>10 kA<br>X<br>X<br>12 to 30<br>10 kA<br>—<br>X<br>X|
## Agency information
- UL Listed, Std. 248-14, Guide JDYX; File E19180, CSA Certified, Class 1422-01, File 53787, RoHS compliant, CE
## Agency information
|% of amp rating<br>Opening time<br>110%<br>4 hours minimum<br>135%<br>AC opens within 1 hour<br>Agency information<br>~~ee~~|% of amp rating<br>Opening time<br>110%<br>4 hours minimum<br>135%<br>AC opens within 1 hour<br>Agency information<br>~~ee~~|% of amp rating<br>Opening time<br>110%<br>4 hours minimum<br>135%<br>AC opens within 1 hour<br>Agency information<br>~~ee~~|Agency information<br>• UL Listed, Std. 248-14, Guide JDYX; File E19180, CSA Certified,<br>Class 1422-01, File 53787, RoHS compliant, CE<br>~~eee~~|Agency information<br>• UL Listed, Std. 248-14, Guide JDYX; File E19180, CSA Certified,<br>Class 1422-01, File 53787, RoHS compliant, CE<br>~~eee~~|Agency information<br>• UL Listed, Std. 248-14, Guide JDYX; File E19180, CSA Certified,<br>Class 1422-01, File 53787, RoHS compliant, CE<br>~~eee~~|Agency information<br>• UL Listed, Std. 248-14, Guide JDYX; File E19180, CSA Certified,<br>Class 1422-01, File 53787, RoHS compliant, CE<br>~~eee~~|
|---|---|---|---|---|---|---|
|Agency information<br>• UL Listed, Std. 248-14, Guide JDYX, File E19180, CSA Certified,<br>C22.2 No. 248. 14, Class 1422-01, File 53787, RoHS compliant, CE|||Catalog no. (amps)<br>FNM-1/10<br>FNM-8/10<br>FNM-2-1/2<br>FNM-6-1/4<br>~~eee~~||||
||||FNM-1/8|FNM-1|FNM-2-8/10|FNM-7|
|Catalog no. (amps)<br>KLM-1/10<br>KLM-1<br>KLM-5<br>KLM-15<br>FNM-15/100<br>FNM-1-1/8<br>FNM-3<br>FNM-8<br>FNM-2/10<br>FNM-1-1/4<br>FNM-3-2/10<br>FNM-9<br>~~a~~<br>~~==8=—~~|||||||
|KLM-1/8<br>KLM-1-1/4|KLM-6|KLM-20|FNM-1/4|FNM-1-4/10|FNM-3-1/2|FNM-10|
|KLM-2/10<br>KLM-1-1/2|KLM-7|KLM-25|FNM-3/10|FNM-1-1/2|FNM-4|FNM-12|
|KLM-1/4<br>KLM-2|KLM-8|KLM-30|FNM-4/10|FNM-1-6/10|FNM-4-1/2|FNM-15|
|KLM-3/10<br>KLM-2-1/2|KLM-9||FNM-1/2|FNM-1-8/10|FNM-5|FNM-20|
|KLM-1/2<br>KLM-3|KLM-10||FNM-6/10|FNM-2|FNM-5-6/10|FNM-25|
|KLM-3/4<br>KLM-4|KLM-12||FNM-3/4|FNM-2-1/4|FNM-6|FNM-30|
## Features
## Features
- Color coded for 600 Vac/dc maximum
- A full range DC performance fuse
- Color coded for 250 Vac maximum
- Melamine tube construction with nickel-plated brass endcaps
- Melamine tube construction with nickel-plated brass endcaps
## Typical applications
Recommended fuse blocks and holders for 13/32" x 1-1/2" fuses, see page 2-2.
- Circuits with high inrush currents (motor/transformer loads)
- Supplemental protection for 125 Vac and 250 Vac inductive circuits
Recommended fuse blocks and holders for 13/32" x 1-1/2" fuses, see page 2-2.
Data sheet no. 2020
Data sheet no. 2028
Eaton.com/bussmannseries
2-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage supplemental fuses — 2**
## BBS fast-acting 13/32" x 1-3/8" supplemental fuse
|||||BBS fast-acting 13/32" x 1-3/8" supplemental fuse|BBS fast-acting 13/32" x 1-3/8" supplemental fuse|BBS fast-acting 13/32" x 1-3/8" supplemental fuse|
|---|---|---|---|---|---|---|
|FNQ time-delay 13/32" x 1-1/2" supplemental fuse||||BBS fast-acting 13/32" x 1-3/8" supplemental fuse|BBS fast-acting 13/32" x 1-3/8" supplemental fuse|BBS fast-acting 13/32" x 1-3/8" supplemental fuse|
|Time-delay supplemental fuse.<br>Color code orange (500 Vac<br>max). For superior protection,<br>Eaton recommends upgrading to<br>Bussmann series Limitron FNQ-R<br>Class CC fuses. See data sheet no.<br>1014.<br>Ratings<br>Fuse amp<br>range<br>IR at rated voltage<br>Agency information<br>500 Vac<br>UL<br>CSA<br>Fast-acting supplemental fuse.<br>Color codes black (600 Vac max<br>1/10 to 6 A), green (250 Vac max<br>7 to 10 A), purple (48 Vac max 12<br>to 30 A). (For superior protection,<br>Eaton recommends upgrading to<br>Bussmann series Low-Peak Class<br>CC fuses. See data sheet no.<br>1023.<br>Ratings<br>Fuse amp<br>range<br>IR at system voltage<br>Agency information<br>600 Vac<br>250 Vac<br>48 Vac<br>UL<br>CSA<br>**2011/65/EU**<br>~~=~~|||||||
|1/10 to 30<br>10 kA|X|X||1/10 to 6<br>10 kA<br>—<br>—|X|X|
|Agency information||||7 to 10<br>—<br>10 kA<br>—|X|X|
|||||12 to 30*<br>—<br>—<br>—|—|—|
|• UL Listed, Std. 248-14, Guide JDYX, File E19180, CSA Certified,<br>C22.2 No. 248.14, Class 1422-01, File 53787, HRC-MISC, RoHS||||* For interrupting rating, contact factory.|||
|compliant, CE||||Agency information|||
|Catalog no. (amps)||||• UL Listed, Std. 248-14 (1/10-6 A@600 Vac, 7-10 A@250 Vac), Guide|||
|FNQ-1/10<br>FNQ-8/10|FNQ-3-2/10|FNQ-9||JDYX, File E19180, CSA Certified, C22.2 No. 248.14 (1/10-6 A@600<br>Vac, 7-10 A@250 Vac), Class 1422-01, File 53787, CE|||
|FNQ-1/8*<br>FNQ-1|FNQ-3-1/2|FNQ-10|||||
|FNQ-15/100*<br>FNQ-1-1/8|FNQ-4|FNQ-12||Catalog no. (amps)|||
|FNQ-3/16<br>FNQ-1-1/4|FNQ-4-1/2|FNQ-14||BBS-1/10<br>BBS-8/10<br>BBS-4|BBS-15||
|FNQ-2/10<br>FNQ-1-1/2|FNQ-5|FNQ-15||BBS-2/10<br>BBS-1<br>BBS-5|BBS-20||
|FNQ-1/4<br>FNQ-1-6/10|FNQ-5-6/10|FNQ-20||BBS-1/4<br>BBS-1-1/2<br>BBS-6|BBS-25||
|FNQ-3/10<br>FNQ-2|FNQ-6|FNQ-25||BBS-4/10<br>BBS-1-6/10<br>BBS-7|BBS-30||
|FNQ-4/10<br>FNQ-2-1/4|FNQ-6-1/4|FNQ-30||BBS-1/2<br>BBS-1-8/10<br>BBS-8|||
|FNQ-1/2<br>FNQ-2-1/2|FNQ-7|||BBS-6/10<br>BBS-2<br>BBS-10|||
|FNQ-6/10<br>FNQ-3|FNQ-8|||BBS-3/4<br>BBS-3<br>BBS-12|||
* Not RoHS compliant.
## Features
## Features
- Color coded for 500 Vac maximum
- Fiber tube construction with nickel-plated brass endcaps
## Typical applications
- Motor control transformers
- Circuits with in-rush currents
- Color coded for 600 Vac (black) 250 Vac (green) and 48 Vac (purple) for maximum
- Fiber tube construction with nickel-plated brass endcaps
## Typical applications
- Control circuits
- Gaseous vapor fixtures
- HID ballasts
Recommended blocks and holders for 13/32" x 1-1/2" fuses, see page 2-2.
- Electronic circuits
- Hand-held meters
Recommended blocks and holders for BBS fuses, see page 2-2.
Data sheet no. 1012
Data sheet no. 2010
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
2-7
## **2 — Low voltage supplemental fuses**
## GBA/GLD fast-acting 1/4" x 1-1/4" pin-indicating supplemental fuse
Fast-acting, pin-indicating fuse.
## Ratings
- Volts — see agency information
## MIC fast-acting 13/32" x 1-1/2" pin-indicating supplemental fuse
Fast-acting, pin-indicating supplemental fuse. Green color code (250 Vac max 1 to 15 A), gray (32 Vac max 20 to 30 A).
- Amps 1/2-15 A
- IR — see agency information
## Agency information
## Ratings
- UL Listed, Std. 248-14, 0-5 A/125 Vac, 10,000 AIC, Guide JDYX, File E19180
|Fuse amp<br>range|IR at voltage rating<br>250 Vac<br>32 Vac|IR at voltage rating<br>250 Vac<br>32 Vac|Agency information<br>UL|Agency information<br>CSA|
|---|---|---|---|---|
||||||
|1|35 A|—|X|—|
|2 to 3|100 A|—|X|—|
|5 to 10|200 A|—|X|—|
|15|750 A|—|X|—|
|~~——————————~&E—«~~|~~——————————~&E—«~~|~~——————————~&E—«~~|~~——————————~&E—«~~|~~——————————~&E—«~~|
|20 to 30<br>~~——————————~&E—«~~|—<br>~~——————————~&E—«~~|10 kA<br>~~——————————~&E—«~~|—<br>~~——————————~&E—«~~|—<br>~~——————————~&E—«~~|
- UL Recognized, 6 A/125 Vac, 1000 AIC 8-15 A/50 Vac/dc, 300 AIC Guide JDYX2, File E19180
- CSA Certified, 0-5 A/125 Vac, 10,000 AIC Class 1422-01, File 53787
> • CE
Catalog no. (amps) 20 to 30 — 10 kA — — ~~——————————~&E—«~~ GBA
Electrical characteristics
|• CE<br>Catalog no. (amps)<br>GBA<br>5 to 10<br>200 A<br>—<br>X<br>—<br>15<br>750 A<br>—<br>X<br>—<br>20 to 30<br>—<br>10 kA<br>—<br>—<br>Electrical characteristics<br>~~——————————~&E—«~~|• CE<br>Catalog no. (amps)<br>GBA<br>5 to 10<br>200 A<br>—<br>X<br>—<br>15<br>750 A<br>—<br>X<br>—<br>20 to 30<br>—<br>10 kA<br>—<br>—<br>Electrical characteristics<br>~~——————————~&E—«~~|• CE<br>Catalog no. (amps)<br>GBA<br>5 to 10<br>200 A<br>—<br>X<br>—<br>15<br>750 A<br>—<br>X<br>—<br>20 to 30<br>—<br>10 kA<br>—<br>—<br>Electrical characteristics<br>~~——————————~&E—«~~|• CE<br>Catalog no. (amps)<br>GBA<br>5 to 10<br>200 A<br>—<br>X<br>—<br>15<br>750 A<br>—<br>X<br>—<br>20 to 30<br>—<br>10 kA<br>—<br>—<br>Electrical characteristics<br>~~——————————~&E—«~~|• CE<br>Catalog no. (amps)<br>GBA<br>5 to 10<br>200 A<br>—<br>X<br>—<br>15<br>750 A<br>—<br>X<br>—<br>20 to 30<br>—<br>10 kA<br>—<br>—<br>Electrical characteristics<br>~~——————————~&E—«~~|
|---|---|---|---|---|
|GBA-1/2<br>GBA-1-1/2<br>GBA-4<br>GBA-10<br>GBA-3/4<br>GBA-2<br>GBA-5<br>GBA-15<br>GBA-1<br>GBA-3<br>GBA-8<br>Electrical characteristics<br>% of fuse rating<br>Opening time<br>110%<br>Indefinitely<br>~~CEere~~|||||
|GLD||||135%<br>1 hour max.|
|GLD-1/2|GLD-1-1/2|GLD-4|GLD-10|Agency information|
|GLD-3/4|GLD-2|GLD-5|GLD-12||
|GLD-1|GLD-3|GLD-6|GLD-15|• UL Listed, Std. 248-14, 1-15 A, Guide JDYX, File E19180, CE|
|Catalog no. (amps)<br>~~Le~~|Catalog no. (amps)<br>~~Le~~|Catalog no. (amps)<br>~~Le~~|Catalog no. (amps)<br>~~Le~~|
|---|---|---|---|
|MIC-1|MIC-5|MIC-15|MIC-30|
|MIC-2|MIC-8|MIC-20||
|MIC-3|MIC-10|MIC-25||
## Features
- Type GBA has a "red" pin indicator providing visual identification of failed circuits, resulting in faster troubleshooting (reduced circuit downtime)
- Type GLD has a plated pin to activate transmitting a electrical signal to indicate the location of opened circuits, resulting in reduced downtime
## Features
- Color coded by maximum voltage rating
## Typical applications
- Control circuits
- Electronic circuits
Recommended fuse blocks/fuse holders for 1/4" x 1-1/4" indicating fuses, see page 2-2.
- Pin indication for visual indication of open fuse condition
- Silver-plated pin for positive, electrical signal activation
- Fiber tube construction with nickel-plated bronze endcaps
## Typical applications
- Power electronic circuits in which fuse opening must be quickly apparent
- Control circuits
- PLC Circuits
Recommended signal block for, 13/32" x 1-1/2" indicating fuses, see page 2-2.
Data sheet no. 2012
Data sheet no. 10246
Eaton.com/bussmannseries
2-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage supplemental fuses — 2**
|FNA time-delay 13/32" x 1-1/2" pin-indicating|FNA time-delay 13/32" x 1-1/2" pin-indicating|FNA time-delay 13/32" x 1-1/2" pin-indicating|FNA time-delay 13/32" x 1-1/2" pin-indicating|||MIS non time-delay 13/32" x 2" pin-indicating|MIS non time-delay 13/32" x 2" pin-indicating|
|---|---|---|---|---|---|---|---|
|supplemental fuse<br>Pin-indicating time-delay<br>supplemental fuse. Color<br>coded green (250 Vac<br>max 1/10 to 6 A), blue<br>(125 Vac max 6-1/4 to 15<br>A) and gray (32 Vac max<br>20 to 30 A).<br>Ratings<br>Fuse amp<br>range<br>IR at system voltage<br>Agency information<br>250 Vac<br>125 Vac<br>32 Vac<br>UL<br>CSA<br>1/10 to 8/10<br>35 A<br>10 kA<br>—<br>X<br>X<br>supplemental fuse and KAZ non-fuse pin-<br>indicating actuator<br>MIS is a non time-delay pin-indicating fuse.<br>KAZ is a non-fuse actuator mounted in<br>parallel with fuses having a 50 amp or larger<br>rating to provide blown fuse dropout for<br>shunt-trip fused switches. To order, specify<br>catalog number KAZ.<br>Ratings<br>MIS fuse<br>KAZ actuator<br>Volts<br>600 Vac<br>600 Vac<br>Amps<br>1-12 A<br>N/A<br>IR<br>200 kA<br>200 kA<br>Dual-tube construction 12A and up<br>~~=~~||||||||
|1 to 6<br>200 A|10 kA|—|X|X||MIS fuse electrical characteristics||
|6-1/4 to 15<br>—|10 kA|—|X|X||||
|||||||||
|20 to 30<br>—|—|1 kA|—|—||MIS Fuse<br>Load|Opening time|
|||||||||
|||||||All<br>110%|4 hrs. (min.)|
|Agency information||||||1-5 A<br>150%|6 min. (max.)|
|• UL Listed, 1/10 to 8/10 A @ 125/250 Vac, 1-15 A @ 125 Vac, Guide||UL Listed, 1/10 to 8/10 A @ 125/250 Vac, 1-15 A @ 125 Vac, Guide||||6-12 A<br>150%|12 min. (max.)|
|JDYX, File E19180, CSA Certified, 1/10 to 10 A @ 125 Vac, Class|||JDYX, File E19180, CSA Certified, 1/10 to 10 A @ 125 Vac, Class|||||
|1422-01, File 53787, CE||||||||
|||||||MIS fuse catalog no. (amps)||
|Catalog no. (amps)||||||MIS-1<br>MIS-3<br>MIS-5|MIS-10|
|FNA-1/10<br>FNA-1||FNA-3|FNA-9|FNA-9||MIS-2<br>MIS-4<br>MIS-8|MIS-12|
|Catalog no. (amps)||||
|---|---|---|---|
|FNA-1/10|FNA-1|FNA-3|FNA-9|
|FNA-1/8|FNA-1-1/8|FNA-3-2/10|FNA-10|
|FNA-15/100|FNA-1-1/4|FNA-3-1/2|FNA-12|
|FNA-2/10|FNA-1-4/10|FNA-4|FNA-15|
|FNA-1/4|FNA-1-1/2|FNA-4-1/2|FNA-20|
|FNA-3/10|FNA-1-6/10|FNA-5|FNA-25|
|FNA-4/10|FNA-1-8/10|FNA-5-6/10|FNA-30|
|FNA-1/2|FNA-2|FNA-6||
|FNA-6/10|FNA-2-1/4|FNA-6-1/4||
|FNA-3/4|FNA-2-1/2|FNA-7||
|FNA-8/10|FNA-2-8/10|FNA-8||
## KAZ agency information
- UL Listed, Guide JDVS, File E58836, CE
## MIS fuse features
- Pin indicator provides visual identification of failed circuits, resulting in faster troubleshooting (reduced circuit downtime)
- Fuse can be used in circuits rated 600 V or less
- High 200 kA interrupting rating for high fault current circuits
MIS fuse typical applications
## Features
- 480 V control circuits
- PLC circuits
- Color coded by maximum voltage rating
## KAZ actuator features
- Pin-indication for visual indication of open fuse condition
- Dual-element, time-delay performance permits close sizing on control transformers and relays
- Convenient means to add open fuse signaling
- Actuator can be used in circuits rated 600 V or less
- Silver-plated pin for positive, electrical signal activation
- High 200 kA interrupting rating for high fault current circuits
- 12 amp and more versions are dual-tube construction
## KAZ actuator typical applications
Recommended signal block for 13/32" x 1-1/2" indicating fuses, see page 2.2.
- Large, shunt-trip fused switches
- Fuse protected circuits rated 50 A or larger with shunt-trip devices
Recommended signal blocks for MIS and KAZ, see page 2-2.
Data sheet no. 2021
Data sheet no. 2029
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
2-9
**2 — Low voltage supplemental fuses** ~~a~~ GLQ fast-acting, size-rejecting supplemental fuse GMQ time-delay, size-rejecting supplemental fuse est
## GLQ fast-acting, size-rejecting supplemental fuse
Fast-acting, size-rejecting in-line fuse. Match fuse and holder amp rating per catalog number table below.
## Ratings
- Volts 300 Vac (or less)
- Amps 1-10 A
- IR 10 kA
Time-delay, size-rejecting in-line fuse. Match fuse and holder amp rating per catalog number table below.
## Ratings
- Volts 300 Vac (or less)
- Amps 1/2 to 6-1/4 A
- IR 10 kA
## Agency information
> • UL Listed, Std. 248-14, (Guide JDYX, File E19180), CSA Certified C22.2 No. 248.14, (Class 1422-01,File 53787), CE Catalog no. (amps) and holders Fuse Holder[1, 2] Fuse Holder[1, 2] GLQ-1 HLQ-1-6/10 GLQ-3 HLQ-3-2/10 GLQ-1-1/2 HLQ-1-6/10 GLQ-4 HLQ-5 GLQ-1-6/10 HLQ-1-6/10 GLQ-5 HLQ-5 GLQ-2 HLQ-3-2/10 GLQ-9 HLQ-10 GLQ-2-1/2 HLQ-3-2/10 GLQ-10 HLQ-10 ~~==>~~ 1 Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 10 A, 300 Vac.
- 2 Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip NO.6374 for panels of thickness 0.043"to 0.062" or NO.4909 for thickness 0.030" to 0.042".
- Note: Do not put tension on line (rear) terminal of fuse holder.
## Features
## Agency information
- UL Listed, Std. 248-14, (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787), CE
|Catalog no. (amps) and holders||
|---|---|
|Fuse<br>Holders1, 2|Fuse<br>Holders1, 2|
|GMQ-1/2<br>HLQ-1/2|GMQ-2-1/2<br>HLQ-3-2/10|
|GMQ-6/10<br>HLQ-1-6/10|GMQ-3<br>HLQ-3-2/10|
|GMQ-8/10<br>HLQ-1-6/10|GMQ-3-2/10<br>HLQ-3-2/10|
|GMQ-1<br>HLQ-1-6/10|GMQ-4<br>HLQ-5|
|GMQ-1-1/4<br>HLQ-1-6/10|GMQ-5<br>HLQ-5|
|GMQ-1-6/10<br>HLQ-1-6/10|GMQ-6-1/4<br>HLQ-8|
|GMQ-2<br>HLQ-3-2/10||
- 1 Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 10 A, 300 Vac.
- 2 Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip NO.6374 for panels of thickness 0.043"to 0.062" or NO.4909 for thickness 0.030" to 0.042"
- Note: Do not put tension on line (rear) terminal of fuse holder.
- In-line, fast-acting circuit protection
## Features
- Rejection feature prevents overfusing
## Typical applications
- In-line, fast-acting circuit protection
- Rejection feature prevents overfusing
- In-line lighting ballast protection
## Typical applications
- In-line lighting ballast protection
HLQ fuse holders for both GLQ and GMQ fuses
Data sheet no. 2033
Data sheet no. 2030
Eaton.com/bussmannseries
2-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage supplemental fuses — 2**
## er
## GLR fast-acting, non size-rejecting supplemental fuse
Fast-acting, non-rejection, in-line fuse. All fuses use the same HLR or HLR-2A holders.
## Ratings
- Volts 300 Vac (or less)
- Amps 3/16-15 A
- IR 10 kA
## GMF/GRF time-delay, non size-rejecting supplemental fuses
Time-delay, non-rejection, in-line fuse. All fuses use the same HLR or HLR-2A holders.
## Ratings
- Volts 300 Vac (or less)
- Amps 3/10-10 A
- IR 10 kA
## Agency information
- UL Listed, Std. 248-14, 0-15 A/300 Vac Guide JDYX, File E19180, CSA Certified C22.2, No. 248-14, 0-10 A/300 V Class 1422-01, File 53787, CE
|Catalog no. (amps) and holders||
|---|---|
|Fuse<br>Holder1, 2*|Fuse<br>Holder1, 2*|
|GLR-1/2<br>HLR|GLR-6<br>HLR|
|GLR-1<br>HLR|GLR-7<br>HLR|
|GLR-1-1/2<br>HLR|GLR-8<br>HLR|
|GLR-1-6/10<br>HLR|GLR-9<br>HLR|
|GLR-2<br>HLR|GLR-10<br>HLR|
|GLR-3<br>HLR|GLR-12<br>HLR|
|GLR-4<br>HLR|GLR-15<br>HLR-2A|
|GLR-5<br>HLR||
- 1 Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12 A, 300 Vac.
- 2 Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip NO.6374 for panels of thickness 0.043"to 0.062" or NO.4909 for thickness 0.030" to 0.042".
- For two leads (one each for line and loadside) order HLR-2A, 15 A, 300 V Note: Do not put tension on line (rear) terminal of fuse holder.
## Agency information
- UL Listed, Std. 248-14 0-10 A, Guide JDYX, File E19180, CSA Certified, Class 1422-01, File 53787, CE
|Catalog no. (amps) and holders||
|---|---|
|Fuse<br>Holder1, 2*|Fuse<br>Holder1, 2*|
|GMF-3/10<br>HLR|GMF-3<br>HLR|
|GMF-1/2<br>HLR|GMF-3-2/10<br>HLR|
|GMF-6/10<br>HLR|GMF-4<br>HLR|
|GMF-8/10<br>HLR|GMF-5<br>HLR|
|GMF-1<br>HLR|GMF-6-1/4<br>HLR|
|GMF-1-1/4<br>HLR|GMF-7<br>HLR|
|GMF-1-6/10<br>HLR|GRF-8<br>HLR|
|GMF-2<br>HLR|GMF-10<br>HLR|
|GMF-2-1/2<br>HLR|GRF-10<br>HLR|
|GMF-2-8/10<br>HLR||
- 1 Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12 A, 300 Vac.
- 2 Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip NO.6374 for panels of thickness 0.043"to 0.062" or NO.4909 for thickness 0.030" to 0.042".
- For two leads order HLR-2A, 15 A, 300 V
## "A" in-line holder
An alternative to the HLR fuse holder is the "A" fuse holder. The A fuse holder comes WITHOUT leads. The customer inserts NO.18 insulated solid copper wire into the lineside receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10 A, 300 Vac, Guide IZLT2, File E14853 and CSA Certified, 10 A, 300 Vac, Class 6225-01, File 47235. Order catalog number A.
## Features
- In-line, fast-acting circuit protection.
## Typical applications
- In-line lighting ballast protection
Note: Do not put tension on line (rear) terminal of fuse holder.
## "A" in-line holder
An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT leads. The customer inserts NO.18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10 A, 300 Vac, Guide IZLT2, File E14853 and CSA Certified, 10 A, 300 Vac, Class 6225-01, File 47235. Order catalog number A.
## Features
- In-line, time-delay circuits protection
## Typical applications
> • In-line lighting ballast protection
HLR-2A HLR fuse holder a fuse holder
Data sheet no. 2031
Data sheet no. 2032
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
2-11
**2 — Low voltage supplemental fuses**
## ATR fast-acting micro blade fuse
Fast-acting, color-coded 2-leg micro blade fuse.
## Ratings
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- Volts 32 Vdc
- Amps 5-30 A
- IR 1000 A
## Agency information
- RoHS compliant
|Catalog no. (amps)|Catalog no. (amps)|||
|---|---|---|---|
|Fuse|Color code|Fuse|Color code|
|ATR-5|Tan|ATR-20|Yellow|
|ATR-7-1/2|Brown|ATR-25|Clear|
|ATR-10|Red|ATR-30|Green|
|ATR-15|Blue|||
## Features
## • Space-savings size
- Industry standard color coding for easy identification of fuse rating
## Typical applications
- Automotive
Recommended holder for ATR fuses, see page 2-14.
## ATM and ATM-LP fast-acting blade fuses
Fast-acting, color-coded blade fuse available in standard and low-profile versions. Standard version available with indication.
**==> picture [89 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
Low-profile<br>2<br>ae<br>ESN U}<br>= 1<br>w/<br>Indicating<br>Standard<br>**----- End of picture text -----**<br>
## Ratings
- Volts 32 Vdc
- Amps 1-30 A
- IR 1000 A
## Agency information
- UL Listed, Guide FHXT, File AU 169 (2-30 A non-indicating ATM)
|Catalog no. (amps)|Catalog no. (amps)|||
|---|---|---|---|
|Non-indicating|*Indicating|Low-profile|Color code|
|ATM-1|—|—|Black|
|ATM-2|—|ATM-2LP|Gray|
|ATM-3|ATM-3ID|ATM-3LP|Violet|
|ATM-4|—|ATM-4LP|Pink|
|ATM-5|ATM-5ID|ATM-5LP|Tan|
|ATM-7-1/2|ATM-7-1/2ID|ATM-7-1/2LP|Brown|
|ATM-10|ATM-10ID|ATM-10LP|Red|
|ATM-15|ATM-15ID|ATM-15LP|Blue|
|ATM-20|ATM-20ID|ATM-20LP|Yellow|
|ATM-25|ATM-25ID|ATM-25LP|Clear|
|ATM-30|ATM-30ID|ATM-30LP|Green|
* Call customer satisfaction for ordering information.
## Features
- Industry standard color coding for easy identification of fuse rating
- Indicating versions show blown fuse at a glance, speeds troubleshooting
## Typical applications
- Automotive
Recommended blocks and holders for ATM fuses, see page 2-14.
Data sheet no. 2048 (ATM), 2050 (ATM-LP)
Eaton.com/bussmannseries
2-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Low voltage supplemental fuses — 2** TESTO ~~sh~~
## ATC fast-acting blade fuse
Fast-acting, color-coded blade fuse for automotive and control circuit applications.
## Ratings
- Volts 32 Vdc
- Amps 1-40 A
- IR 1000 A
## Agency information
Standard Indicating
## MAX (MAXI) fast-acting blade fuse
Fast-acting, color-coded, high amp blade fuse. Available with and without indication.
## Ratings
- Volts 32 Vdc
> • Amps Standard Indicating
- 20-80 A (non-indicating)
- 20-100 A (indicating)
- IR 1000 A
- UL Recognized, (1-40 A) (Guide JFHR2, File E56412), SAE Standard J1284
## Catalog no. (amps)
|• 20-100 A (indicating)<br>• IR 1000 A<br>Catalog no. (amps)<br>Agency information<br>• UL Recognized, (1-40 A) (Guide JFHR2, File E56412), SAE<br>Standard J1284|• 20-100 A (indicating)<br>• IR 1000 A<br>Catalog no. (amps)<br>Agency information<br>• UL Recognized, (1-40 A) (Guide JFHR2, File E56412), SAE<br>Standard J1284|• 20-100 A (indicating)<br>• IR 1000 A<br>Catalog no. (amps)<br>Agency information<br>• UL Recognized, (1-40 A) (Guide JFHR2, File E56412), SAE<br>Standard J1284|• 20-100 A (indicating)<br>• IR 1000 A<br>Catalog no. (amps)<br>Agency information<br>• UL Recognized, (1-40 A) (Guide JFHR2, File E56412), SAE<br>Standard J1284|• 20-100 A (indicating)<br>• IR 1000 A<br>Catalog no. (amps)<br>Agency information<br>• UL Recognized, (1-40 A) (Guide JFHR2, File E56412), SAE<br>Standard J1284|
|---|---|---|---|---|
|Non-indicating<br>*Indicating<br>Color code<br>MAX-20<br>MAX-20ID<br>Yellow<br>MAX-25<br>—<br>Gray<br>MAX-30<br>MAX-30ID<br>Green<br>Catalog no. (amps)<br>Non-indicating<br>*Indicating<br>Color code<br>ATC-1<br>—<br>Black<br>ATC-2<br>—<br>Gray<br>~~es~~|||||
|ATC-3|ATC-3ID|Violet||MAX-35<br>—<br>Brown|
|ATC-4<br>ATC-5<br>ATC-7-1/2<br>ATC-10<br>ATC-15|—<br>ATC-5ID<br>ATC-7-1/2ID<br>ATC-10ID<br>ATC-15ID|Pink<br>Tan<br>Brown<br>Red<br>Blue||MAX-40<br>MAX-40ID<br>Orange<br>MAX-50<br>MAX-50ID<br>Red<br>MAX-60<br>MAX-60ID<br>Blue<br>MAX-70<br>MAX-70ID<br>Tan<br>MAX-80<br>MAX-80ID<br>Clear|
|ATC-20|ATC-20ID|Yellow||—<br>MAX-100ID<br>Purple|
|ATC-25|ATC-25ID|Clear||* Call customer satisfaction for ordering information.|
|ATC-30|ATC-30ID|Green||Features|
|ATC-35|ATC-35ID|Blue-green||• Color coded housing for easy identification of fuse rating|
|ATC-40|ATC-40ID|Orange||Indicating versions show blown fuse at a glance, speeds|
- Indicating versions show blown fuse at a glance, speeds troubleshooting
* Call customer satisfaction for ordering information.
## Features
## Typical applications
- Industry standard color coding for easy identification of fuse rating
- Automotive
- Indicating versions show blown fuse at a glance, speeds troubleshooting
Recommended holders for MAX fuses, see page 2-14.
## Typical applications
- Automotive
- Low voltage control circuits
Recommended blocks and holders for ATC fuses, see page 2-14.
Data sheet no. 2009
Data sheet no. 2049
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
2-13
**2 — Low voltage supplemental fuses** TONusage
In-line fuse holders for ATM, ATC and MAX fuses
PCB fuseclips for ATM and ATC fuses
ATM fuseclips
Catalog no. 1A5778
Catalog no. 1A5779
**==> picture [142 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
LED open<br>fuse indicator<br>easyID LED indicating holders available<br>for ATM, ATC and MAX fuses<br>**----- End of picture text -----**<br>
- 15 A
- 15 A
- Nickel-plated brass
- Nickel-plated brass/glass-filled nylon
Dimensions — mm (in)
**==> picture [259 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 1.9 Dimensions — mm (in)14.68 (0.578) 1.24 (0.049)<br>(0.075)<br>4.75<br>3.96 (0.187)<br>(0.156)<br>Base Fuseclips<br>en Ea s<br>4.98<br>(0.196) 8.64<br>(0.34)<br>11.18(0.44) (0.125)3.18<br>(0.125)3.18 (0.062)1.57 Yi (0.057)1.45 3.66 (0.144) (0.1)2.54 (0.062)1.57<br>1 e 3.66 4.47 3.66 e<br>1.57 (0.144) (0.176) (0.144)<br>PA (0.144)3.66 2.18 A (0.062) ota e<br>(0.086)2.18<br>3.66 4.47 3.66 ai ee Ø1.65 (0.065) TYP-4 se<br>(0.144) (0.176) (0.144)<br>**----- End of picture text -----**<br>
Typical in-line blade fuse holders with leadwires
In-line fuse holders for ATM, ATC and MAX blade fuses. Versions available with and without covers and with open fuse indication.
Ratings
- Volts 32 Vdc
- Amps 80% continuous of fuse rating. See catalog numbers table for individual holder fuses amp ranges.
**==> picture [371 x 318] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|Max|3.66|
|Catalog no.|Description|amps|Electrical connection|(0.144)3.66|(0.086)2.18|
|ee|ATR holder|3.66|4.47|3.66|
|(0.144)|(0.176)|(0.144)|
|HH2|Black w/ cover|15|2x4" #16 red leadwire|
|ATM holders - not for low-profile ATM fuses|
|HHL|Black w/ cover*|20|2x4" #16 black leadwire|Ø1.65 (0.065) TYP-4|
|aeaamae68?)|ese|OOO|
|HHM|Black w/ cover|30|2x4" #12 red leadwire|Land pattern|
|HHU|Black w/ cover|30|2x4" #12 red leadwire|
|ATM-FHID|Indicating holder,|20|2x4" #16 black leadwire|
|black w/ cover|
|Low-profile ATM holder|
|HHV|Black w/ cover|20|2x4" #12 red leadwire|
|ATC holders|
|HHC|Yellow|20|2x4" #16 black leadwire|ATC fuseclips|
|HHD|Black|30|2x4" #12 yellow leadwire|Catalog no. 1A5600|
|HHF|Black w/ cover|20|2x4" #16 yellow leadwire|
|•|20 A|
|HHG|Black w/ cover|30|2x4" #12 yellow leadwire|
|HHR|Black w/ cover|30|2x5" #12 red leadwire|•|Tin-plated cartridge brass|
|HHS|Blue, self-stripping|20|Accepts #14-18 leadwire|
|Dimensions — in (mm)|
|ATC-FHID|Indicating holder,|20|2x6" #16 black leadwire|
|black w/ cover|
|0.295|
|a|MAX holders|(7.49)|
|HHX|Black w/ cover|60|2x5" #6 red leadwire|
|0.33|
|MAX-FHID|Indicator, black w/|60|2x5" #6 red leadwire|(8.38)|
|7|cover|0.053|
|OT|*Please note that BK/HHL-R does not have a cover|(1.35)0.053|
|0.2|
|Fuses must be fully inserted into the holder to provide a solid|4|0.15|(5.08)|
|connection. Poor or improper fuse insertion can result in fuse and|(3.81)0.15|
|holder failure and loss of power and/or circuit protection.|
**----- End of picture text -----**<br>
Land pattern
## Catalog no. 1A5780
- 15 A
- Nickel-plated brass/glass-filled nylon
- Tin-plated cartridge brass
Dimensions — mm (in)
0.295 19.30 (0.76) (7.49) 4.45 (0.175) 3.18 0.33 (0.125) (8.38) Base (1.35)0.053 ro (0.271)6.88 ~~ror~~ ae Fuseclips 0.2 0.08 ~~4~~ (3.81)0.15 (5.08) ~~"~~ 0.09(2.03) 11.1 e ~~e~~ (0.25)6.35 (2.29) (0.437) ~~So~~
**==> picture [108 x 70] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.27<br>(0.05)<br>5.08 4.06 5.08<br>(0.2) (0.16) (0.2)<br>1!<br>Ø2.54 (0.1) TYP-4 ± 0.05<br>Land pattern<br>**----- End of picture text -----**<br>
Data sheet no. ATM fuses 2128 (HHM, HHL) ATC fuses 2107 (HHC, HHD, HHF, HHG) Max fuses 2129 (HHX)
Data sheet no. 2131
Eaton.com/bussmannseries
2-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Electronic, PCB and small dimension fuses — 3**
## Contents
Full range of small dimension fast-acting and time-delay fuses
|Description||Section<br>page|||
|---|---|---|---|---|
|Product|Catalog symbol/type||||
|Fuses<br>5x15 mm fuses|C515, C519 time-delay<br>C518, C520 fast-acting|2|||
||C517 fast acting<br>GDB, S500, S500-V fast-acting|3|||
|IEC 5x20 mm fuses|GDA, S501, S501-V fast-acting<br>S505, S506SC time-delay|4|||
|UL 5x20 mm fuses<br>1/4" x 5/8" fuse|GDC, S505H, S505H-V, S505SCH,<br>S506 S506-V time-delay<br>GMA, GMA-V fast-acting<br>GMC, GMC-V time-delay<br>GMD GMD-V time-delay<br>AGA fast-acting|5<br>6<br>7|Electronic, PCB, small|dimension fuses|
|1/4" x 7/8" fuse<br>1/4" x 1" fuse|AGW fast-acting<br>AGX fast acting|8|||
||AGC, AGC-V, ABC, ABC-V fast-acting|9|||
|1/4" x 1-1/4" fuses|GBB, GBB-V fast-acting<br>MDL, MDL-V time-delay|10|||
||MDQ, MDQ-V, MDA, MDA-V time-<br>delay|11|||
|PCB holders and fuseclips|||||
|5x20 mm holders<br>1/4" x 1-1/4" holders<br>~~——~~|H15-V, H15-H, HTC-60M<br>HBH-I, HBH-M, HBV-I, HBV-M, HBW-<br>I, HBW-M|12<br>13|||
||HTC-15M, HTC-140M, HTC-200M,||||
|5 mm fuseclips<br>1/4" fuseclips<br>9/32" fuseclips|HTC-210M, 1A3399, 1A5018,<br>1A5601, 1A5602<br>1A1119, 1A1120, 1A1907, 1A3398,<br>1A4533, 1A4534<br>5681, 5682<br>5674<br>~~a~~|14<br>15|||
|||16|||
|13/32" fuseclips|5960 1A3400||||
|9/16" fuseclips|5592||||
For blocks and holders, see the following pages in Section 8
|Fuse diameter|Pages|
|---|---|
|Panel mount blocks||
|1/4" fuses|4-5|
|Through panel holders||
|5 mm fuses|41|
|1/4" fuses|41-42|
|In-line holders||
|5 mm fuses|46|
|1/4" fuses|46-48|
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
3-1
**3 — Electronic, PCB and small dimension fuses**
C519 ferrule and C515 axial lead time-delay 5x15 mm glass tube fuses
## Ratings
- Volts
- 125 Vac (3.5-7 A)
- 250 Vac (125mA-3 A)
- 32 Vdc (self certified)
- Amps 125mA-7 A
- IR
- 25 A (350mA @ 600 Vac)
- 35 A (125mA-1A @ 250 Vac)
- 100 A (1.25-3 A @ 250 Vac)
- 400 A (3.5-7 A @ 125 Vac)
**==> picture [23 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
C520 ferrule and C518 axial lead fast-acting 5x15 mm glass tube fuses
## Ratings
- Volts • 250 Vac
- 32 Vdc (self certified)
- Amps 100mA-5 A
- IR
- 35 A (100mA-750mA @ 250 Vac)
- 10 kA (100mA-5 A @ 125 Vac)
- 100 A (1.5-3.5 A @ 250 Vac)
- 200 A (4-5 A @ 250 Vac)
## Agency information
**==> picture [22 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- 10 kA (125mA-3 A @ 125 Vac)
- UL Recognized, Guide JDYX2, File E19180, CSA Certified, Class 1422-01, File 53787, RoHS compliant, CE
## Agency information
- UL Listed, Guide JDYX, File E19180 125mA-250mA and 375mA-3 A, UL Recognized, Guide JDYX2, File E19180, 350mA and 3.5-7 A, CSA Certified, Class 1422-01, File 53787 125mA-250mA and 375mA-3 A, RoHS compliant, CE
## Features
- Small footprint saves space in equipment
- Fast-acting for maximum component protection
## Features
- Available in ferrule and axial leaded configurations
- Time-delay for closer sizing on inductive circuits
## Typical applications
## Typical application
- Electronic circuits
> • Printed circuit boards
- Electronic circuits
- Printed circuit boards
**==> picture [263 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Pe|Catalog no. (amps)|
|Os|Ferrule|
|C520-100-R|C520-500-R|C520-2.5-R|C520-5-R|
|C520-125-R|C520-750-R|C520-3-R|
|C520-250-R|C520-1.5-R|C520-3.5-R|
|C520-375-R|C520-2-R|C520-4-R|
|Axial lead|
|C518-100-R|C518-375-R|C518-2-R|C518-3.5-R|
|C518-125-R|C518-500-R|C518-2.5-R|C518-4-R|
|C518-250-R|C518-750-R|C518-3-R|C518-5-R|
**----- End of picture text -----**<br>
**==> picture [537 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Ferrule|
|Des|Catalog no. (amps)|Os|
|C520-100-R|C520-500-R|C520-2.5-R|C520-5-R|
|Ferrule|
|C520-125-R|C520-750-R|C520-3-R|
|C519-125-R|C519-600-R|C519-1.6-R|C519-3.5-R|
|C520-250-R|C520-1.5-R|C520-3.5-R|
|C519-250-R|C519-750-R|C519-2-R|C519-4-R|
|C520-375-R|C520-2-R|C520-4-R|
|C519-350-R|C519-1-R|C519-2.25-R|C519-5-R|
|Axial lead|
|C519-375-R|C519-1.25-R|C519-2.5-R|
|C518-100-R|C518-375-R|C518-2-R|C518-3.5-R|
|C519-500-R|C519-1.5-R|C519-3-R|
|C518-125-R|C518-500-R|C518-2.5-R|C518-4-R|
|Axial lead|
|C518-250-R|C518-750-R|C518-3-R|C518-5-R|
|C515-125-R|C515-750-R|C515-2-R|C515-5-R|
|C515-250-R|C515-800-R|C515-2.25-R|C515-6-R|
|C515-350-R|C515-1-R|C515-2.5-R|C515-7-R|
|C515-375-R|C515-1.25-R|C515-3-R|
|C515-500-R|C515-1.5-R|C515-3.5-R|
|C515-600-R|C515-1.6-R|C515-4-R|
**----- End of picture text -----**<br>
Data sheet no. 2006 (C515) and 2007 (C519)
Data sheet no. 2026 (C518) and 2027 (C520)
Eaton.com/bussmannseries
3-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Electronic, PCB and small dimension fuses — 3**
## C517 axial lead fast-acting 5x15 mm glass tube fuse
## Ratings
- Volts
- 350 Vac
- 32 Vdc (self certified)
- Amps 3 A
## • IR
- 100 A @ 350 Vac*
- 100 A @ 250 Vac
- 10 kA @ 125 Vac
- 350 Vac/100 A IR is UL Recognized.
## Agency information
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
S500 ferrule (GDB[†] ) and S500-V axial lead fast-acting, low breaking capacity 5x20 mm glass tube fuses
## Ratings
- Volts
- 250 Vac (or less)
- 32 Vdc (self certified)
- Amps 32mA-10 A
- IR
- 35 A (32mA-3.15 A)
- 40 A (4 A)
- 63 A (6.3 A)
- 80 A (8 A)
**==> picture [23 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- 100 A (10 A)
- UL Listed, Guide JDYX, File E19180, CSA Certified, Class 142201, File 53787, UL Recognized, Guide JDYX2, File E19180, RoHS compliant, CE
## Features
- Small footprint saves space in equipment
- Fast-acting for maximum component protection
- 350 Vac rating for 277 V ballast circuit protection
## Typical applications
- Electronic circuits
- Printed circuit boards
- Electronic ballast protection
To order, use catalog number C517-3-R
Agency information
- cURus, SEMKO, VDE, BSI, IMQ, CCC, RoHS compliant, CE
- Agency information not applicable to all ratings; see data sheet for details.
## Features
- Fast-acting for maximum protection, conforms to IEC 60127-2 (160mA-10 A)
Typical applications
> • Electronic circuits
|Catalog no. (amps)*<br>~~PO~~|Catalog no. (amps)*<br>~~PO~~|Catalog no. (amps)*<br>~~PO~~|Catalog no. (amps)*<br>~~PO~~|
|---|---|---|---|
|S500-32-R|S500-160-R|S500-800-R|S500-4-R|
|S500-40-R|S500-200-R|S500-1-R|S500-5-R|
|S500-50-R|S500-250-R|S500-1.25-R|S500-6.3-R|
|S500-63-R|S500-315-R|S500-1.6-R|S500-8-R|
|S500-80-R|S500-400-R|S500-2-R|S500-10-R|
|S500-100-R|S500-500-R|S500-2.5-R||
|S500-125-R|S500-630-R|S500-3.15-R||
- GDB is not available with axial leads. To order axial leads, place “V” in the S500 catalog number. E.g., S500-V-32-R.
- When ordering GDB versions, do not add “-R” suffix to catalog number.
Data sheet no. 2025
Data sheet no. 2052 (S500), 2015 (GDB)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
3-3
**3 — Electronic, PCB and small dimension fuses** ~~LC~~
S501 ferrule (GDA[†] ) and S501-V Axial lead fast-acting high breaking capacity 5x20 mm ceramic tube fuses
S505 ferrule, and S505SC axial lead time-delay, high-breaking capacity 5x20 mm ceramic tube fuses
**==> picture [23 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
**==> picture [23 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
## Ratings
## • Volts
- 250 Vac (or less)
- 32 Vdc (self certified)
- Amps 50mA-10 A**
- IR 1500 A @ 250 Vac
## Agency information
- cURus, SEMKO, VDE, IMQ, CCC, CSA, BSI, MITI/JET, RoHS compliant, CE
- Agency information not applicable to all ratings, see data sheet for details.
## Ratings
- Volts
- 250 Vac (or less)
- 32 Vdc (self certified)
- Amps 500mA-12 A
- IR 1500 A @ 250 Vac
Agency information
- cURus, CSA, IMQ, VDE, SEMKO, CCC/CQC, PSE/JET, KC, BS, RoHS compliant
- Agency information not applicable to all ratings, see data sheet for details.
## Features
## Features
- Fast-acting for maximum protection
- Time-delay performance ideal for inductive circuits.
- High break capacity for use in higher fault energy electronic circuitry
- Conforms to IEC standards.
Typical applications
- Conforms to IEC standards
> • Electronic circuits
Typical applications
|Catalog no. (amps)*<br>~~Le~~|Catalog no. (amps)*<br>~~Le~~|Catalog no. (amps)*<br>~~Le~~|
|---|---|---|
|S505-500-R**<br>S505-1.6-R|S505-4-R|S505-10-R|
|~~ié’RNNOTVT~~|~~ié’RNNOTVT~~|~~ié’RNNOTVT~~|
|S505-800-R**<br>S505-2-R<br>~~ié’RNNOTVT~~|S505-5-R<br>~~ié’RNNOTVT~~|S505-12-R**<br>~~ié’RNNOTVT~~|
|S505-1-R<br>S505-2.5-R|S505-6.3-R||
|S505-1.25-R<br>S505-3.15-R|S505-8-R||
- Electronic circuits
|• Electronic circuits<br>Catalog no. (amps)*<br>S505-500-R**<br>S505-1.6-R<br>S505-4-R<br>S505-10-R<br>~~Le~~|• Electronic circuits<br>Catalog no. (amps)*<br>S505-500-R**<br>S505-1.6-R<br>S505-4-R<br>S505-10-R<br>~~Le~~|• Electronic circuits<br>Catalog no. (amps)*<br>S505-500-R**<br>S505-1.6-R<br>S505-4-R<br>S505-10-R<br>~~Le~~|• Electronic circuits<br>Catalog no. (amps)*<br>S505-500-R**<br>S505-1.6-R<br>S505-4-R<br>S505-10-R<br>~~Le~~|• Electronic circuits<br>Catalog no. (amps)*<br>S505-500-R**<br>S505-1.6-R<br>S505-4-R<br>S505-10-R<br>~~Le~~|• Electronic circuits<br>Catalog no. (amps)*<br>S505-500-R**<br>S505-1.6-R<br>S505-4-R<br>S505-10-R<br>~~Le~~|• Electronic circuits<br>Catalog no. (amps)*<br>S505-500-R**<br>S505-1.6-R<br>S505-4-R<br>S505-10-R<br>~~Le~~|
|---|---|---|---|---|---|---|
|Catalog no. (amps)*<br>S505-800-R**<br>S505-2-R<br>S505-5-R<br>S505-12-R**<br>~~_————Srtrié’RNNOTVT~~|||||||
|S501-50-R|S501-200-R|S501-800-R|S501-3.15-R|S505-1-R|S505-2.5-R|S505-6.3-R|
||||||||
|S501-63-R|S501-250-R|S501-1-R|S501-4-R|S505-1.25-R|S505-3.15-R|S505-8-R|
||||||||
|S501-80-R|S501-315-R|S501-1.25-R|S501-5-R|* To order axial leads, place “SC” in catalog number. E.g., S505SC-2-R.||* To order axial leads, place “SC” in catalog number. E.g., S505SC-2-R.|
|S501-100-R|S501-400-R|S501-1.6-R|S501-6.3-R|** Axial leads not available.|||
|S501-125-R|S501-500-R|S501-2-R|S501-8-R||||
|S501-160-R|S501-630-R|S501-2.5-R|S501-10-R||||
- GDA is not available with axial leads. To order axial leads, place “V” in the S501 catalog number. E.g., S501-V-125-R.
- When ordering GDA version, do not add “-R” suffix to catalog number, GDA is not available above 6.3 A.
Data sheet no. 2051 (S501), 2014 (GDA)
Data sheet no. 2037
Eaton.com/bussmannseries
3-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Electronic, PCB and small dimension fuses — 3**
## ETON men
S506 ferrule (GDC[†] ) and S506-V axial lead time-delay low breaking capacity 5x20 mm glass tube fuses **2011/65/EU 2011/65/EU** Ratings • Volts • 250 Vac (or less) • 32 Vdc (self certified) • Amps 32mA-15 A** • IR 35 A @ 250 Vac Woy Agency information • UR, CSA, cURus, SEMKO, VDE, BSI, IMQ, VDE, PSE/JET, CCC, RoHS compliant
S505H ferrule, and S505H-V and S505SCH axial time-delay high breaking capacity 5x20 mm ceramic tube fuses
## Ratings
- Volts
- 600 Vac/400 Vdc (S505H 500mA-5 A
- 500 Vac/400 Vdc (S505H
- 6.3-10 A)
- 250 Vac (S505SCH)
- Amps
- 500mA-10 A (S505H)
- 3.15-6.3 A (S505SCH)
- Agency information not applicable to all ratings; see data sheet for details.
- IR @ 250 Vac
- 35 A (S505H)
- 1.5 kA (S505SCH / 50 Hz / 250 Vac / 400 Vdc)
## Features
- 100 A max AC
- Time-delay for inductive circuits
Agency information
- Conforms to IEC standards
Typical applications
- cURus, CCC, CQC, TUV, PSE/JET (S505H)
- cURus, KC, CQC, TUV (S505SCH)
> • Electronic circuits
- RoHS compliant
- Agency information not applicable to all ratings; see data sheets for details.
## Features
- Time-delay, high breaking capacity
- Conforms to IEC standards
Typical applications
## ~~Bee~~ Catalog no. (amps)*
|Catalog no. (amps)*<br>~~Bee~~|Catalog no. (amps)*<br>~~Bee~~|~~Bee~~|~~Bee~~|
|---|---|---|---|
|S506-32-R|S506-160-R|S506-800-R|S506-4-R|
|S506-40-R|S506-200-R|S506-1-R|S506-5-R|
|S506-50-R|S506-250-R|S506-1.25-R|S506-6.3-R|
|S506-63-R|S506-315-R|S506-1.6-R|S506-8-R|
|S506-80-R|S506-400-R|S506-2-R|S506-10-R|
|S506-100-R|S506-500-R|S506-2.5-R|S506-12.5-R|
|S506-125-R|S506-630-R|S506-3.15-R|S506-15-R|
- Power supplies/adapters
> • Desktops/notebooks
|Catalog no. (amps)<br>S505H*<br>~~pe~~|Catalog no. (amps)<br>S505H*<br>~~pe~~|Catalog no. (amps)<br>S505H*<br>~~pe~~|
|---|---|---|
|S505H-500-R|S505H-1.6-R|S505H-4-R<br>S505H-10-R|
|S505H-800-R|S505H-2-R|S505H-5-R|
|S505H-1-R|S505H-2.5-R|S505H-6.3-R|
|S505H-1.25-R|S505H-3.15-R|S505H-8-R|
|S505SCH (axial lead only|S505SCH (axial lead only||
|S505SCH-3.15-R|S505SCH-5-R|S505SCH-6.3-R|
- GDC is not available with axial leads. To order axial leads, place “V” in the S506 catalog number. E.g., S506-V-15-R.
- When ordering GDC version, do not add “-R” suffix to catalog number., GDC fuses are not available above 6.3 A.
- To order an axial lead S505H fuse, place “V” in catalog number. E.g., S505H-V-5-R.
Data sheet no. 4406 (S505H), 10401 (S505SCH)
Data sheet no. 4332 (S506), 2016 (GDC)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
3-5
**3 — Electronic, PCB and small dimension fuses**
GMA ferrule and GMA-V axial leads fast-acting 5x20 mm glass tube fuses
**==> picture [32 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>@><br>**----- End of picture text -----**<br>
## Ratings
- Volts
- 250 Vac (63mA-3 A)
- 125 Vac (3.15-15 A)
- 32 Vdc (self certified)
- Amps 63mA-15 A
## • IR
- 35 A (63mA-1 A @ 250 Vac, p.f. = 0.7-0.8)
- 10 kA (63mA-6 A @ 125 Vac, p.f. = 0.7-0.8)
- 100 A (1.25-2.5 A @ 250 Vac, p.f. = 0.7-0.8)
- 200 A (7-8 A @ 125 Vac, p.f. = 1.0)
- 150 A (10-15 A @ 125 Vac, p.f. = 1.0)
## Agency information
- UL Listed, Std. 248-14 Guide JDYX, File E19180 up to 6 A, UL Recognized, Guide JDYX2, File E19180, 7-15 A, CSA Certified, Class 1422-01,File 53787 up to 6 A, PSE Approval 1-15 A, RoHS compliant, CE
## Features
- Fast-acting for maximum protection
## Typical applications
> • Electronic circuits
|Catalog no. (amps)*<br>~~eee~~|Catalog no. (amps)*<br>~~eee~~|Catalog no. (amps)*<br>~~eee~~|Catalog no. (amps)*<br>~~eee~~|
|---|---|---|---|
|GMA-63-R|GMA-600-R|GMA-2-R|GMA-7-R|
|GMA-100-R|GMA-750-R|GMA-2.5-R|GMA-8-R|
|GMA-125-R|GMA-800-R|GMA-3.15-R|GMA-10-R|
|GMA-200-R|GMA-1-R|GMA-3.5-R|GMA-15-R|
|GMA-250-R|GMA-1.25-R|GMA-4-R||
|GMA-300-R|GMA-1.5-R|GMA-5-R||
|GMA-500-R|GMA-1.6-R|GMA-6-R||
* To order axial leads, place “V” in catalog number. E.g., GMA-V-8-R.
GMC ferrule and GMC-V axial lead medium time-delay 5x20 mm glass tube fuses Ratings **2011/65/EU** • Volts • 250 Vac (63mA-3.15 A) • 125 Vac (3.5-10 A) • 32 Vdc (self certified) j I @
- Amps 63mA-10 A
- IR
- 35 A (63mA-1 A @ 250 Vac, p.f. = 0.7-0.8)
- 10 kA (63mA-6 A @ 125 Vac, p.f. = 0.7-0.8)
- 100 A (1.25-3.15 A @ 250 Vac, p.f. = 0.7-0.8)
- 200 A (6.3-10 A @ 125 Vac, p.f. = 1.0)
## Agency information
- UL Listed, Std. 248-14, Guide JDYX, File E19180 up to 6.3 A, UL Recognized, Guide JDYX2, File E19180 7-10 A, CSA Certified, Class 1422-01, File 53787 up to 6.3 A, MITI Approval, 1-10 A, KC, RoHS compliant, CE
- KC not applicable to all ratings; see data sheet for details
## Features
- Conforms to UL standards
## Typical applications
- Electronic circuits
|Catalog no. (amps)*|Catalog no. (amps)*|||
|---|---|---|---|
|GMC-63-R|GMC-315-R|GMC-1.25-R|GMC-5-R|
|GMC-80-R|GMC-400-R|GMC-1.5-R|GMC-6-R|
|GMC-100-R|GMC-500-R|GMC-1.6-R|GMC-6.3-R|
|GMC-125-R|GMC-600-R|GMC-2-R|GMC-7-R|
|GMC-150-R|GMC-630-R|GMC-2.5-R|GMC-8-R|
|GMC-200-R|GMC-750-R|GMC-3.15-R|GMC-10-R|
|GMC-250-R|GMC-800-R|GMC-3.5-R||
|GMC-300-R|GMC-1-R|GMC-4-R||
* To order axial leads, place “V” in catalog number. E.g., GMC-V-5-R.
Data sheet no. 2017
Data sheet no. 4395
Eaton.com/bussmannseries
3-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Electronic, PCB and small dimension fuses — 3** UBT ~~a~~
GMD ferrule and GMD-V axial leads time-delay
## 5x20 mm glass tube fuses
## Ratings
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- Volts
- 250 Vac
- 32 Vdc (self certified)
- Amps 125mA-4 A
- IR
- 10 kA (125mA-3 A @ 125 Vac, p.f. = 0.7-0.8)
- 10 kA (4 A @ 125 Vac, p.f. = 1.0)
- 35 A (125mA-1 A @ 250 Vac, p.f. = 0.7-0.8)
- 100 A (1.2-3. A @ 250 Vac, p.f. = 0.7-0.8)
- 200 A (4 A @ 250 Vac, p.f. = 1.0)
## Agency information
- UL Listed Guide JDYX, File E19180, UL Recognized Card (4 A), Guide JDYX2, File E19180, 4 A, CSA Certified, Class 1422-01, File 53787, PSE/JET, File 1641-31003-1001, RoHS complaint, CE
- Agency information not applicable to all ratings; see data sheet for details
## Features
- Time-delay for inductive circuits
- Conforms to UL standards
## Typical applications
> • Electronic circuits
AGA fast-acting 1/4˝ x 5/8˝ glass tube fuse
## Ratings
- Volts
- 125 Vac (or less)
- 32 Vdc (self certified)
- Amps 1-30 A
- IR
- 10 kA (1 to 1-1/2 A @ 125 Vac)
- 200 A (2-5 A @ 125 Vac)
- 1000 A (6-30 A @ 32 Vac)
## Agency information
- UL Listed, Std. 248-14, Guide JDYX, File E19180 up to 3-1/2 A UL Recognized, Guide JDYX2 12-30 A, CE
## Features
- Fast-acting for maximum protection
- Size rejects insertion of other fuse types
## Typical applications
> • Electronic circuits
|Catalog no. (amps)<br>~~ee~~|Catalog no. (amps)<br>~~ee~~|Catalog no. (amps)<br>~~ee~~|Catalog no. (amps)<br>~~ee~~|
|---|---|---|---|
|AGA-1|AGA-3|AGA-7-1/2|AGA-25|
|AGA-1-1/2|AGA-5|AGA-10|AGA-30|
|AGA-2|AGA-6|AGA-15||
|AGA-2-1/2|AGA-7|AGA-20||
|Catalog no. (amps)*<br>~~a~~|Catalog no. (amps)*<br>~~a~~|Catalog no. (amps)*<br>~~a~~|Catalog no. (amps)*<br>~~a~~|
|---|---|---|---|
|GMD-125-R|GMD-375-R|GMD-800-R|GMD-2-R|
|GMD-150-R|GMD-400-R|GMD-1-R|GMD-2.5-R|
|GMD-200-R|GMD-500-R|GMD-1.2-R|GMD-3-R|
|GMD-250-R|GMD-600-R|GMD-1.25-R|GMD-4-R|
|GMD-300-R|GMD-630-R|GMD-1.5-R||
|GMD-315-R|GMD-750-R|GMD-1.6-R||
* To order axial leads, place “V” in catalog number. E.g., GMD-V-2.5-R.
Data sheet no. 2019
Data sheet no. 2039
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
3-7
**3 — Electronic, PCB and small dimension fuses**
AGW fast-acting 1/4˝ x 7/8˝ glass tube fuse
## Ratings
- Volts
- 32 Vac
- 32 Vdc (self certified)
- Amps 1-30 A
- IR 1 kA AC
## Features
AGX fast-acting 1/4˝ x 1˝ glass tube fuse
## Ratings
- Volts
- 250 Vac (1//4-20 A)
- 125 Vac (25-30 A)
- 32 Vdc (1/4-30 A)
- Amps 1/4-30 A
- IR
- 35 A (1/4-1 A @ 250 Vac)
- Fast-acting for maximum protection
## Typical applications
- Electronic circuits
- 10 kA (1/4-10 A @ 125 Vac)
- 200 A (15-20 A @ 125 Vac)
- 100 A (25-30 A @ 125 Vac)
- 1000 A (8-30 A @ 32 Vac)
|Catalog no. (amps)||||
|---|---|---|---|
|AGW-1|AGW-3|AGW-7-1/2|AGW-25|
|AGW-1-1/2<br>AGW-2|AGW-4<br>AGW-5|AGW-10<br>AGW-15|AGW-30|
|AGW-2-1/2|AGW-6|AGW-20||
## Agency information
- cULus up to 10 A, Guide JDYX, File E 19180 and Guide JDYX7, File E19180, UL Recognized Card 15-30 A Guide JDYX2, File E19180, CSA Component Acceptance Card 15-30 A Class No. 1422-01, File 53787
## Features
- Size rejects inserting of other fuse types
## Typical applications
- Electronic circuits
|Catalog no. (amps)||||
|---|---|---|---|
|AGX-1/4|AGX-1|AGX-4|AGX-15|
|AGX-3/10|AGX-1-1/4|AGX-5|AGX-20|
|AGX-3/8|AGX-1-1/2|AGX-6|AGX-25|
|AGX-4/10|AGX-2|AGX-7|AGX-30|
|AGX-1/2|AGX-2-1/2|AGX-8||
|AGX-3/4|AGX-3|AGX-10||
Data sheet no. 2040
Data sheet no. 2041
Eaton.com/bussmannseries
3-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Electronic, PCB and small dimension fuses — 3**
AGC ferrule and AGC-V axial lead fast-acing 1/4" x 1-1/4˝ glass tube fuses
## Ratings
- Volts
- 250 Vac (1/20-10 A)
- 32 Vac (12-40 A)
- 32 Vdc (self certified)
- Amps 1/20-40 A
- IR
- 35 A (1/20-1 A @ 250 Vac)
- 100 A (11/4-3 A @ 250 Vac)
- 200 A (4-10 A @ 250 Vac)
- 10 kA (1/20-10 A @ 125 Vac)
- 1000 A (12-40 A @ 32 Vac)
## Agency information
**==> picture [23 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
ABC ferrule and ABC-V axial leads fast-acting 1/4" x 1-1/4˝ ceramic tube fuse
## Ratings
- Volts
- 250 Vac/125 Vdc (1/4-15 A, 20-30 A)*
- 250 Vac (18 A)
- 32 Vdc (self certified)
- Amps 1/4-30 A
- IR**
- 35 A (1/4-1 A @ 250 Vac)
- 100 A (11/2-3 A @ 250 Vac)
- 200 A (4-10 A @ 250 Vac)
- 750 A (12-15 A @ 250 Vac)
- 400 A (18-20 A @ 250 Vac)
- 10 kA (1/4-15 A @ 125 Vac)
**==> picture [22 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- 1 kA (18-30 A @ 125 Vac)
- UL Listed, Guide JDYX, File E19180, up to 10 A, UL Recognized, Guide JDYX2, File E19180, 12-30 A, CSA Certified, Class 142201, CSA Component Acceptance Card, Class No. 1422-30, RoHS compliant, CE
- 10 kA (1/4-15, 20 A @ 125 Vdc)
- 400 A (25-30 A @ 125 Vdc)
- 200 A (25-30 A @ 250 Vac)
## Features
- CSA approvals for 25 A and 30 A are at 125 Vac – IR 1000 A and Vdc – IR 400 A (IR 1000 A at 75 Vdc)
- ** Interrupting ratings measured at 70% – 80% power factor on AC. The interrupting ratings for 18 A and 20 A were measured at 85%-95% power factor on AC. The interrupting ratings for 25 A and 30 A were measured at 89% power factor on AC.
- Original electronic glass tube fuse
- Fast-acting for maximum protection
- Wide amp/volt ratings allow versatility of protecting electronic circuits
## Agency information
## Typical applications
- UL Listed, Std. 248-14, Guide JDYX File E19180 up to 15 A; UL Recognized, Guide JDYX2, File E19180, 18-30 A; CSA Certified, Class 1422-01 and 1422-30, File 53787, RoHS compliant, CE
> • Electronic circuits
|Catalog no. (amps)*<br>~~eC~~|Catalog no. (amps)*<br>~~eC~~|Catalog no. (amps)*<br>~~eC~~|Catalog no. (amps)*<br>~~eC~~|Catalog no. (amps)*<br>~~eC~~|Features|||
|---|---|---|---|---|---|---|---|
|AGC-1/20-R|AGC-3/4-R|AGC-5-R|AGC-15-R||• Ceramic body allows for higher amp/volt rating combinations|Ceramic body allows for higher amp/volt rating combinations|Ceramic body allows for higher amp/volt rating combinations|
|AGC-1/10-R|AGC-1-R|AGC-6-R|AGC-20-R|||||
|AGC-1/8-R|AGC-1-1/4-R|AGC-7-R|AGC-25-R||Typical applications|||
|AGC-3/16-R|AGC-1-1/2-R|AGC-7-1/2-R|AGC-30-R||• Electronic circuits|||
|AGC-2/10-R<br>AGC-2-R<br>AGC-8-R<br>AGC-35-R<br>AGC-1/4-R<br>AGC-2-1/4-R<br>AGC-9-R<br>AGC-40-R<br>AGC-3/10-R<br>AGC-2-1/2-R<br>AGC-10-R<br>AGC-3/8-R<br>AGC-3-R<br>AGC-12-R<br>~~”:—sCédE eee~~||||~~eee~~|Catalog no. (amps)<br>ABC-1/4-R<br>ABC-2-R<br>ABC-6-R<br>ABC-15-R<br>ABC-1/2-R<br>ABC-2-1/2-R<br>ABC-7-R<br>ABC-18-R<br>~~eee~~|||
|AGC-1/2-R|AGC-4-R|AGC-14-R|||ABC-3/4-R<br>ABC-3-R|ABC-8-R|ABC-20-R|
|Catalog no. (amps)<br>ABC-1/4-R<br>~~eee~~|ABC-2-R<br>~~eee~~|ABC-6-R<br>~~eee~~|ABC-15-R<br>~~eee~~|
|---|---|---|---|
|ABC-1/2-R|ABC-2-1/2-R|ABC-7-R|ABC-18-R|
|ABC-3/4-R|ABC-3-R|ABC-8-R|ABC-20-R|
|ABC-1-R|ABC-4-R|ABC-10-R|ABC-25-R|
|ABC-1-1/2-R|ABC-5-R|ABC-12-R|ABC-30-R|
* To order axial leads, place “V” in catalog number. E.g., AGC-V-1/10-R.
- To order axial leads, place “V” in catalog number. E.g., ABC-V-7-R.
Data sheet no. 2543
Data sheet no. 2000
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
3-9
**3 — Electronic, PCB and small dimension fuses** ~~Ts~~
GBB ferrule and GBB-V axial lead very-fast-acting 1/4" x 1-1/4˝ ceramic tube fuses
## Ratings
- Volts 250 Vac/125 Vdc
- Amps 1-30 A
- IR
- 200 A @ 250 Vac
- 200 A (20-30 A @ 125 Vac/dc)
- 10 kA (1-15 A @ 125 Vac/dc)
## Agency information
**==> picture [22 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
MDL ferrule and MDL-V axial lead time-delay 1/4" x 1-1/4˝ glass tube fuses
## Ratings
- Volts
- 250 Vac (1/16-8 A)
- 32 Vac (9-30 A)
- 32 Vdc (self certified)
- Amps 1/16-30 A
- IR*
- 35 A (1/16-1 A @ 250 Vac)
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- 100 A (11/4-3 A @ 250 Vac)
- UL Recognized, Std. 248-14, Guide JFHR2, File E56412, CSA Component Acceptance Class 1422-30, File 53787, RoHS complaint, CE
## Features
- Very fast-acting performance allows protection of highly sensitive electronic circuitry
## Typical applications
> • Electronic circuits
|Catalog no. (amps)*<br>~~eee~~|Catalog no. (amps)*<br>~~eee~~|Catalog no. (amps)*<br>~~eee~~|
|---|---|---|
|GBB-1-R<br>GBB-4-R|GBB-8-R|GBB-15-R|
|GBB-1-1/4-R<br>GBB-5-R|GBB-9-R|GBB-20-R|
|GBB-2-R<br>GBB-6-R|GBB-10-R|GBB-25-R|
|GBB-3-R<br>GBB-7-R|GBB-12-R|GBB-30-R|
- To order axial leads, place “V” in catalog number. E.g., GBB-V-10-R.
- 200 A (4-8 A @ 250 Vac)
- 10000 A (1/16-8 A @ 125 Vac)
- 1000 A (9-30 A @ 32 Vac)
- Interrupting ratings were measured at 70% – 80% power factor on AC, and at a time constant described in UL 198L.
## Agency information
- UL Listed, Guide JDYX, File E19180 up to 8 A; CSA Certified Class 1422-01 up to 8 A; UL Recognized, Guide JDYX2, File E19180, 9-30 A; CSA Component Acceptance, Class 1422-30, 9-30 A, RoHS compliant, CE
## Features
- Time-delay allows close sizing on inductive circuits
## Typical applications
> • Electronic circuits
## ~~eee~~ Catalog no. (amps)*
|Catalog no. (amps)*<br>~~eee~~|Catalog no. (amps)*<br>~~eee~~|~~eee~~|~~eee~~|
|---|---|---|---|
|MDL-1/16-R|MDL-1/2-R|MDL-3-R|MDL-10-R|
|MDL-1/10-R|MDL-3/4-R|MDL-3-2/10-R|MDL-12-R|
|MDL-1/8-R|MDL-1-R|MDL-4-R|MDL-15-R|
|MDL-2/10-R|MDL-1-1/4-R|MDL-5-R|MDL-20-R|
|MDL-3/16-R|MDL-1-1/2-R|MDL-6-R|MDL-25**|
|MDL-1/4-R|MDL-2-R|MDL-7-R|MDL-30**|
|MDL-3/10-R|MDL-2-1/4-R|MDL-8-R||
|MDL-3/8-R|MDL-2-1/2-R|MDL-9-R||
- To order axial leads, place “V” in catalog number. E.g., MDL-V-3-R.
- ** RoHS compliant construction not available.
Data sheet no. 2013
Data sheet no. 2004
Eaton.com/bussmannseries
3-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Electronic, PCB and small dimension fuses — 3**
MDQ ferrule and MDQ-V axial lead dual-element, time-delay 1/4" x 1-1/4˝ glass tube fuses
## Ratings
- Volts
- 250 Vac (1/100-7 A)
- 32 Vac (7-1/2 to 15 A)
- 32 Vdc (self certified)
- Amps 1/100-15 A
- IR
- 35 A (1/100-1 A @ 250 Vac)
- 100 A (1-1/4 to 3 A @ 250 Vac)
- 200 A (4-7 A @ 250 Vac)
- 1000 A (7-1/2 to 12 A @ 32 Vac)
## Agency information
MDA ferrule and MDA-V axial lead time-delay 1/4" x 1-1/4˝ ceramic tube fuses
## Ratings
- Volts **2011/65/EU**
- 250 Vac (or less)
- 125 Vdc (20-30 A)
- 32 Vdc (self certified)
- Amps 1/4-30 A
- IR**
- 35 A (1/4 to 1 A @ 250 Vac)
- 100 A (1-1/2 to 2 A @ 250 Vac)
- 200 A (2-1/2 to 10 A @ 250 Vac)
- 750 A (12-15 A @ 250 Vac)
- 1500 A (20-30 A @ 250 Vac)
- 10 kA (1/4-30 A @ 125 Vac)
- UL Listed, Std. 248-14, Guide JDYX, File E19180 1/16-7 A, CSA Component Acceptance, Class 1422-01, File 47233 1/16 -15 A, UL Recognized, Guide JDYX2, File E19180, 7-1/2-15 A.
- 10 kA (20-30 A @ 125 Vdc)
- ** Interrupting ratings were measured at 70% – 80% power factor on AC, and at a time constant described in UL 248.
## Features
Agency information
- Dual-element design allows closer sizing to inductive circuits than any other fuses
## Typical applications
- UL Listed, Std. 248-14, Guide JDYX, File E19180 up to 20 A, CSA Certified, Class 1422-01, File 53787 up to 20 A. UL Recognized, Guide JDYX2, File E19180, 25-30 A, CSA Component Acceptance, Class 1422-30, 25-30 A, RoHS compliant, CE
> • Electronic relay and control circuits
## Features
|• Electronic relay and control circuits|• Electronic relay and control circuits|• Electronic relay and control circuits|• Electronic relay and control circuits|• Electronic relay and control circuits|Component Acceptance, Class 1422-30, 25-30 A, RoHS compliant,<br>CE<br>Features|Component Acceptance, Class 1422-30, 25-30 A, RoHS compliant,|
|---|---|---|---|---|---|---|
|Catalog no. (amps)*<br>MDQ-1/100<br>MDQ-3/10<br>MDQ-1-1/2<br>MDQ-5<br>~~hee~~|||||• Ceramic body for higher amp/volt ratings||
|MDQ-1/32|MDQ-3/8|MDQ-1-6/10|MDQ-6||• Inventory consolidation by replacing MDL fuses allows for reduced<br>SKU investment and minimizing potential for misapplying fuse||
|MDQ-1/16|MDQ-4/10|MDQ-1-8/10|MDQ-6-1/4||||
|MDQ-1/10|MDQ-1/2|MDQ-2|MDQ-7||Typical applications||
|MDQ-1/8|MDQ-6/10|MDQ-2-1/4|MDQ-7-1/2||• Electronic circuits||
|MDQ-15/100<br>MDQ-3/4<br>MDQ-2-1/2<br>MDQ-8<br>MDQ-175/1000<br>MDQ-8/10<br>MDQ-2-8/10<br>MDQ-9<br>MDQ-3/16<br>MDQ-1<br>MDQ-3<br>MDQ-10<br>Catalog no. (amps)*<br>MDA-1/4-R<br>MDA-2-R<br>MDA-6-R<br>MDA-15-R<br>~~|~~|||||||
|MDQ-2/10|MDQ-1-2/10|MDQ-3-2/10|MDQ-12||MDA-1/2-R<br>MDA-2-1/2-R<br>MDA-7-R|MDA-20-R|
|MDQ-1/4|MDQ-1-1/4|MDQ-4|MDQ-15||MDA-3/4-R<br>MDA-3-R<br>MDA-8-R|MDA-25 A-R|
|* To order axial leads, place “V” in catalog number. E.g., MDQ-V-1-1/4.|* To order axial leads, place “V” in catalog number. E.g., MDQ-V-1-1/4.|* To order axial leads, place “V” in catalog number. E.g., MDQ-V-1-1/4.|||MDA-1-R<br>MDA-4-R<br>MDA-10-R|MDA-30 A-R|
||||||MDA-1-1 /2-R<br>MDA-5-R<br>MDA-12-R||
- To order axial leads, place “V” in catalog number. E.g., MDA-V-1-1/2-R.
Data sheet no. 2044
Data sheet no. 2002
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
3-11
**3 — Electronic, PCB and small dimension fuses** ~~i~~ 7 H15-V vertical mount 5 mm fuse H15-H horizontal mount 5 mm HTC-60M four-leg stand-off mount 5 mm fuse holder
H15-H horizontal mount 5 mm fuse holder with threaded cap
**==> picture [351 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
H15-V vertical mount 5 mm fuse H15-H horizontal mount 5 mm<br>holder with threaded cap fuse holder with threaded cap<br>2011/65/EU 2011/65/EU<br>, od °<br>**----- End of picture text -----**<br>
**==> picture [171 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>| .<br>Ratings<br>**----- End of picture text -----**<br>
## Ratings
## Ratings
- Volts 250 Vac
- Volts 250 Vac
- Volts 250 Vac
- Amps 10 A (cURus and VDE)
- Amps 6.3 (cURus and VDE)
- Amps 10 A (cURus) 6.3 A (VDE)
- Temperature rise 41°C
- Temperature rise 41°C
## Agency information
## Agency information
## Agency information
- cURus Recognized, Guide IZLT2/IZLT8, |File E14853
- cURus Recognized, Guide IZLT2/IZLT8, File E14853
- cURus Recognized, Guide IZLT2/IZLT8, File E14853
- VDE File 4004459
- VDE File 40039714
- VDE File 40039714
## Materials
## Materials
## Materials
> • Tin-plated brass terminals
- Tin-plated clip
- Tin-plated clip
Catalog no. Qty. • Tin-plated copper terminals • Tin-plated copper terminals HTC-60M 10 • Thermoplastic body (UL 94V0, glow wire • Thermoplastic body (UL 94V0, glow wire ~~ee~~ test: 960°C per IEC 695-2-1) test: 960°C per IEC 695-2-1) BK-HTC-60M 100 (bulk) Dimensions - in (mm) ~~ss~~ Catalog no. Carton qty. ~~tm~~ Catalog no. Carton qty. BK-H15-V-1 200 BK-H15-H-1 200 BK1-H15-V-1 1000 BK1-H15-H-1 1000 0.886 0.354 BK-H15-V-1-B 100 holder body only BK-H15-H-1-B 100 holder body only (22.5) (9) ~~ens~~ BK-H15-V-1-K 100 holder cap only BK-H15-H-1-K 100 holder cap only 0.551 (14) Dimensions - in (mm) Dimensions - in (mm) ~~ee id~~ 0.138 1.303 0.512 1.303 0.512 (3.5) (33.1) (13) (33.1) (13) Mounting 0.591 S S holes (15) Printed circuit Ø 0.102 Ø 0.051 ~~ter~~ 0.461 ~~ier~~ 0.461 ~~_~~ board (11.7) Printed circuit board (11.7) (2.6) (1.3) Mounting holes Mounting holes Ø 0.051 ± 0.002 (Typ.) 0.394 (10.0) Ø 0.051 ± 0.002 (Typ.) (1.03 ± 0.05) (1.03 ± 0.05) 0.394 (10.0) Eo ~~e~~ e
Data sheet no. 4426
Data sheet no. 4426
Data sheet no. 2110
Eaton.com/bussmannseries
3-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Electronic, PCB and small dimension fuses — 3**
HBH-I (1/4" x 1-1/4˝) and HBH-M (5x20 mm) horizontal mount fuse holders
Dimensions - in (mm)
## Ratings
- UL 16 A/250 V
- CSA 12 A/250 V
- VDE 6.3 A/250 V
- SEMKO 10 A/250 V
## Agency information
- UL Recognized, Guide IZLT2, File EI4853, CSA Certified, Class 6225-01, File 47235, VDE 4009241 (HBV, HBW), SEMKO 800444, CE
## Electrical
- Insulation resistance 10 MΩ 500 Vdc
HBV-I (1/4" x 1-1/4˝) and HBV-M (5x20 mm) vertical mount fuse holders with stability pins
HBW-I (1/4" x 1-1/4˝) and HBW-M (5x20 mm) vertical mount fuse holder without stability pins
Dimensions - in (mm)
Dimensions - in (mm)
**==> picture [335 x 379] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.51 0.51<br>(13.0) 0.531 (13.0) 0.531<br>(13.5) ©: (13.5)<br>1.855 1.855<br>(47.0) i 0.2 Ff (47.0) oO<br>(5.0)<br>0.2<br>(5.0)<br>i<br>(1.05)0.04 —O-0- (10.0)0.4 (1.05)0.04 0.4<br>(10.0)<br>s e t Owz a<br>0.580 0.1 (2.54) Ø, 4 \ \<br>(14.9 0.05 (1.3) Ø, 2 0.580 0.05 (1.3) Ø, 2<br>(14.9<br>Replacement fuse caps<br>High dielectric molded phenolic with a UL FBI and FBM fuse caps fit PCB fuse holders<br>94V0 flammability rating HBH-_, HBV-_ and HBW-_.<br>Fuse carrier and knob: spring-loaded, To order, specify Catalog numbers:<br>bayonet-type, tin-plated brass with • FBI for 1/4" diameter fuses<br>screwdriver slot<br> • FBM for 5 mm diameter fuses<br>“Kicked” terminals (all) and stability pins<br>on HBV and HBW<br>Temperature rating (RTI): body 150ºC,<br>knob 130ºC<br>FBI FBM<br>HBV HBW<br>**----- End of picture text -----**<br>
## Material
- High dielectric molded phenolic with a UL 94V0 flammability rating
- Fuse carrier and knob: spring-loaded, bayonet-type, tin-plated brass with screwdriver slot
## Mounting
- “Kicked” terminals (all) and stability pins on HBV and HBW
- Temperature rating (RTI): body 150ºC, knob 130ºC
- Contact resistance less than 0.005 Ω @ 200mV
- Dielectric strength over 200 V/mil
Data sheet no. 2118
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
3-13
## **3 — Electronic, PCB and small dimension fuses**
## HTC-15M, HTC-140M 5 mm fuse holder and snapon cover
Ratings
- 250 V / 6.3 A / 1.6 W
Agency information
- cURus, Guide 1ZLT2 and IZLT8, File E14853
- VDE 40004458
- RoHS compliant
**==> picture [195 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.047" 0.345"<br>(26.6mm) (9.0mm) 2011/65/EU<br>HTC-140M<br>0.571" Cover<br>(14.5mm)<br>0.217"<br>0.531" (5.5mm)<br>(13.5mm) Mounting Holes<br>0.890"<br>0.866" (22.60mm)<br>(22.0mm) 0.177" 0.059" [+] _ 0.002" Dia. (Typ.)<br>(4.5mm) (1.50 _ [+] .05mm)<br>**----- End of picture text -----**<br>
**==> picture [263 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog no. Description<br>**----- End of picture text -----**<br>
|HTC-15M<br>HTC-140M|Holder<br>Holder|only<br>with|natural color cover|
|---|---|---|---|
|HTC-150M*|Holder|with|transparent cover|
- Available in bulk only, order BK/HTC-150M.
## HTC-200M 5 mm fuseclip
**==> picture [263 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.319" 0.50"<br>0.177" (8.1mm) (12.7mm) 2011/65/EU<br>(4.5mm)<br>0.157"<br>0.929" (3.99mm)<br>0.61" (23.6mm)<br>(15.5mm)<br>(0.79mm)0.031" (5.5mm)0.217" (0.3mm)0.012"<br>0.50" 0.50"<br>(12.7mm) (12.7mm)<br>Catalog no. Material Description<br>HTC-200M Tape and fan fold pack<br>Tin-plated bronze<br>AP/HTC-200M Ammo pack 1000 pieces per box<br>BUSS BUSS BUSS<br>**----- End of picture text -----**<br>
1A3399 low profile 5 mm fuseclips with end stops and straight leads
**==> picture [263 x 121] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.225" 2011/65/EU<br>0.125"<br>(3.2mm) (5.7mm) (1.6mm)0.030" 0.115" (1.6mm)0.062"<br>(2.9mm)<br>0.060" 0.125" 0.188" 0.254" 0.237"<br>(1.5mm) (3.2mm) (4.8mm) (6.5mm) (6.0mm)<br>Catalog no. Material* Finish<br>1A3399-01 BeCu Silver<br>1A3399-04-R BeCu Bright tin<br>1A3399-10-R Copper alloy Bright tin<br>**----- End of picture text -----**<br>
- BeCu recommended for more than 15 A.
## 1A5018 high profile 5 mm fuseclips with end stops and straight leads
**==> picture [264 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.180"<br>0.440" (4.57mm) 2011/65/EU<br>(11.2mm)<br>0.230"<br>0.047" 0.140" 0.180" (5.84mm)<br>(1.2mm) (3.7mm) (4.6mm)<br>Catalog no. Material* Finish<br>1A5018-07 Copper alloy Silver<br>1A5018-10-R Copper alloy Bright tin<br>**----- End of picture text -----**<br>
- BeCu 1A3399 fuseclips recommended for more than 15 A.
## 1A5601 5 mm fuseclip (≤ 7 A)
**==> picture [264 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.344" [+] 0.015" 0.246" 0.250"<br>(8.73mm [+] 0.38mm) (6.3mm) (6.35mm)<br>(8.73mm 0.344" [+][+] 0.38mm) 0.015" 2011/65/EU<br>0.141" [+] 0.015" 0.060" 0.266"<br>(3.58mm [+] 0.38mm) (1.5mm) (6.75mm)<br>(0.56mm 0.022" [+][+] 0.002" 0.05mm) (0.81mm0.032" ++ 0.002" 0.05mm)<br>Catalog no. Material Finish<br>1A5601 Cartridge brass Bright tin<br>**----- End of picture text -----**<br>
## 1A5602 fuseclip with end stops (≤ 7 A)
## HTC-210M 5 mm fuseclip with end stops
**==> picture [264 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.32mm 2011/65/EU<br>2.54mm 8.73mm 2.29mm 2.54mm<br>6.26mm<br>3.91mm<br>6.22mm<br>2.85mm 1.46mm 2.54mm<br>Catalog no. Material Description<br>HTC-210M Tape and fan fold pack<br>Tin-plated bronze<br>AP/HTC-210M Ammo pack 1000 pieces per box<br>**----- End of picture text -----**<br>
**==> picture [264 x 120] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.219"<br>(5.57mm) 2011/65/EU<br>(12.70mm)0.500" (6.35mm)0.250" (3.56mm)0.140"<br>0.093"<br>(2.36mm)<br>0.216" 0.047"<br>(5.48mm) LEGS TO FIT (1.19mm)<br>IN 0.052" (1.3mm) DIA.<br>HOLES ON CENTER<br>Catalog no. Material Finish<br>1A5602 Cartridge brass Bright tin<br>**----- End of picture text -----**<br>
Data sheet no. 2110
Data sheet no. 2131
Eaton.com/bussmannseries
3-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Electronic, PCB and small dimension fuses — 3**
1A1119 1/4" fuseclips with end stops and angled-in leads
**==> picture [225 x 60] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.285" (7.24mm)<br>2011/65/EU<br>0.420" (10.67mm)<br>0.250" (6.5mm)<br>0.080" (2.03mm) 0.155" (3.9mm) 0.290" 0.360" (7.4mm)(9.14mm)<br>**----- End of picture text -----**<br>
**==> picture [262 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog no. Material* Finish<br>**----- End of picture text -----**<br>
|1A1119-04-R|High performance copper|Bright tin|
|---|---|---|
|1A1119-05|High performance copper|Silver|
|1A1119-10-R|Cartridge brass|Bright tin|
1A3398 PCB 1/4" fuseclips without end stops with straight leads
**==> picture [264 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.245" 2011/65/EU<br>0.255" (6.2mm) 0.155"<br>(6.5mm) 0.41" (3.94mm)<br>(10.4mm)<br>0.102" Dia. 0.28"<br>(2.6mm) (7.1mm)<br>(1.5mm)0.06"0.32" (3.6mm)0.14" (7.1mm)0.280"<br>(8.13mm)<br>Catalog no. Material Finish<br>1A3398-07-R Cartridge brass Bright tin<br>**----- End of picture text -----**<br>
* High performance copper recommended for more than 15 A.
1A1120 1/4" fuseclips without end stops or angled-in leads
**==> picture [263 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.272”[6.91] 2011/65/EU<br>0.400”±.010<br>[6.35]0.250” CL [10.16±0.25] Ø 0.130”±.003[3.3mm±0.08] 0.187”[4.75] 0.312”<br>0.155”±.010 [7.92]<br>[3.94±0.25]<br>0.080”<br>[2.03] 0.290”±.010<br>0.320” [7.37±0.25]<br>[8.13] 0.363”±.003<br>[9.22±0.08]<br>Catalog no. Material* Finish<br>1A1120-02 Cartridge brass None/bright dipped<br>1A1120-05 High performance copper Silver<br>1A1120-06-R High performance copper Bright tin<br>1A1120-09-R Cartridge brass Bright tin<br>**----- End of picture text -----**<br>
1A4533 1/4" fuseclips without end stops or angled out leads
**==> picture [263 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.245" 2011/65/EU<br>(6.2mm)<br>0.155" 0.102"<br>0.410" (3.94mm) (2.6mm)<br>(10.4mm)<br>0.255"<br>(6.5mm)(1.5mm)0.060" (3.81mm)0.150" (5.79mm)(8.20mm)0.228"0.323" (8.13mm)0.320 " (7.11mm)0.280"<br>Catalog no. Material* Finish<br>1A4533-01-R High performance copper Bright tin<br>1A4533-06-R Cartridge brass Bright tin<br>**----- End of picture text -----**<br>
- High performance copper recommended for more than 15 A.
* High performance copper recommended for more than 15 A.
1A1907 1/4" fuseclips with end stops and straight leads
**==> picture [264 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.245"<br>(6.5mm)0.255" (6.2mm) 0.155" 2011/65/EU<br>0.410" (3.94mm)<br>(10.4mm)<br>0.102" Dia. 0.280"<br>(1.5mm)0.060"0.320" (3.6mm)0.140" (7.1mm)0.280" (2.6mm) (7.1mm)<br>(8.13mm)<br>Catalog no. Material* Finish<br>1A1907-02 Cartridge brass None/bright dipped<br>1A1907-03-R High performance copper Bright tin<br>1A1907-05 High performance copper Silver<br>1A1907-06-R Cartridge brass Bright tin<br>**----- End of picture text -----**<br>
1A4534 1/4" fuseclips with end stops and angled out leads
**==> picture [263 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.245" 2011/65/EU<br>(6.2mm)<br>0.155" 0.102"<br>0.410" (3.94mm) (2.6mm)<br>(10.4mm)<br>0.255"<br>(6.5mm)(1.5mm)0.06" (3.81mm)0.150" (5.74mm)(8.15mm)0.226"0.321" (8.13mm)0.32" (7.11mm)0.28"<br>Catalog no. Material* Finish<br>1A4534-01-R High performance copper Bright tin<br>1A4534-06-R Cartridge brass Bright tin<br>**----- End of picture text -----**<br>
- High performance copper recommended for more than 15 A.
- High performance copper recommended for more than 15 A.
Data sheet no. 2131
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
3-15
**3 — Electronic, PCB and small dimension fuses**
5681 and 5682 1/4" fuseclips with mounting holes
**==> picture [219 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø F Ø F<br>C D B C Endstop D 2011/65/EU<br>E E<br>Figure 1 Figure 2<br>**----- End of picture text -----**<br>
|Catalogno.<br>Clip<br>mat.<br>Finis|h<br>Dimensions - in<br>B<br>C<br>D<br>E<br>Ø F<br>Ref.|
|---|---|
|Without end stop||
|5681-01<br>BeCu<br>Silve|r<br>†<br>0.265<br>0.41<br>0.32<br>0.132<br>Fig. 1|
|With end stop||
|5682-01<br>BeCu<br>Silve<br>5682-02|r<br>0.108<br>0.262<br>0.41<br>0.32<br>0.132<br>Fig. 2<br>0.131<br>ht tin<br>0.106|
|5682-11-R<br>BeCu<br>Brig||
1A3400 fuseclips with end stops and straight leads for 13/32˝ dia. fuses
**==> picture [263 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.470"<br>(11.94mm) 0.710" (1.27mm)0.050" (11.1mm)0.437" 2011/65/EU<br>(18.03mm) 0.218"<br>(5.54mm)<br>0.080"<br>(2.03mm) 0.380" 0.142" Dia.<br>0.470" (9.65mm) (3.61mm)<br>(11.94mm)<br>1A3400-09 and 1A3400-10<br>Catalog no. Clip mat. Finish Max amps<br>1A3400-09-R Copper-clad steel Bright tin 20<br>1A3400-10-R Copper-clad steel Silver 30<br>**----- End of picture text -----**<br>
Data sheet no. 2131
† Hole in center of both clip and contact area.
## Data sheet no. 2132
5674 PCB fuseclips with mounting holes for 9/32˝ dia. fuses
|B|C<br>D<br>E<br>Figure 1<br>End<br>stop<br>Ø F<br>**2011/65/EU**|
|---|---|
|Catalogno.<br>Clip<br>mat.<br>Finis|h<br>Dimensions - in<br>B<br>C<br>D<br>E<br>Ø F<br>Ref.|
|With end stop||
|5674-01<br>BeCu<br>Silve<br>5674-10<br>Brigh|r<br>0.168<br>0.356<br>0.52<br>0.38<br>0.172<br>Fig. 1<br>t tin|
Data sheet no. 2132
5960 PCB fuseclips with mounting holes for 13/32˝ dia. fuses
||Ø F||
|---|---|---|
|B|C<br>D<br>E<br>Figure 1<br>End<br>stop|**2011/65/EU**|
|Catalogno.<br>Clip<br>mat.<br>Finis|h<br>Dimensions - in<br>B<br>C<br>D<br>E||
|||Ø F<br>Ref.|
|With end stop|||
|5960-07<br>BeCu<br>Silve<br>5960-09|r<br>0.168<br>0.387<br>0.71<br>0.47<br>0.2|0.196<br>Fig. 1<br>0.172|
Data sheet no. 2132
5592 PCB fuseclips with mounting holes for 9/16˝ dia. fuses
|Ø F|Ø F|
|---|---|
|C<br>D<br>E<br>Figure 1<br> <br>**2011/65/EU**||
|Catalogno.<br>Clip<br>mat.<br>Finis|h<br>Dimensions - in<br>B<br>C<br>D<br>E<br>Ø F<br>Ref.|
|Without end stop||
|5592-01<br>BeCu<br>Silve|r<br>0.252<br>0.56<br>0.875<br>0.6<br>0.2<br>Fig. 1|
Data sheet no. 2132
Eaton.com/bussmannseries
3-16
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## Contents
|Fuse type|Volts<br>Amprange<br>Catalogsymbol/size<br>Sectionpage|
|---|---|
|Compact high speed fuses||
|Fuses|500 Vac/dc<br>50 to 400<br>CHSF<br>3|
|UL Class J full range drive fuse||
|Fuses|600 Vac/450 Vdc<br>1 to 600<br>DFJ<br>4|
|North American fuses||
||130 Vac/dc<br>1000 to 4000<br>FWA<br>5|
||150 Vac/dc<br>70 to 1000<br>FWA<br>6|
||250 Vac/dc<br>35 to 2500<br>FWX<br>7|
|Fuses|500 Vac/dc<br>35 to 1600<br>FWH<br>8<br>600 Vac<br>1 to 1000<br>KAC<br>9|
||600 Vac<br>35 to 800<br>KBC<br>10|
||700 Vac/dc<br>5 to 1200<br>FWP<br>11-12|
||1000 Vac/800 Vdc<br>35 to 2000<br>FWJ<br>13|
|Accessories|Modular fuse blocks<br>14|
|British Standard BS88 fuses||
||240-250-280 Vac/150 Vdc<br>6 to 180<br>LCT, LET<br>15|
|Fuses|240-250 Vac/150 Vdc<br>160 to 900<br>LMT, LMMT<br>16<br>690-700 Vac/500 Vdc<br>6 to 200<br>CT, ET, FE, EET and FEE<br>17-18|
|Accessories|690-700 Vac/350-450-500 Vdc<br>160 to 710<br>FM, FMM, MT and MMT<br>19-20<br>Tripindicators, clips and microswitches<br>21|
Continued next page
## Lead the charge with compact designs
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-1
## **4 — High speed fuses**
## Contents
**==> picture [537 x 618] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse type Volts Amp range Catalog symbol/size Section page<br>Ferrule<br>150 Vac/dc 5 to 30 FWA-_A10F (10x38mm) 22<br>150 Vac/dc 35 to 60 FWA-_A21F (21x51mm)<br>250 Vac/dc 1 to 50 FWX (14x51mm) 23<br>500 Vac 0.25 to 30 FWH-_A6F (6x32mm) 24<br>500 Vac/dc 1 to 30 FWH-_14F (14x51mm) 25<br>600-700 Vac/700 Vdc 1 to 32 FWC (10x38mm) 26<br>690 Vac 4 to 32 FWP-_G10F (10x38mm) 27<br>Fuses 690-700 Vac/600-700 Vdc 1 to 50 FWP-_A14F (14x51mm) 28<br>690 Vac 4 to 50 FWP-_G14F_ (14x51mm) 29<br>700 Vac/dc 20 to 100 FWP-_A22F (22x58mm) 30<br>690 Vac 20 to 100 FWP-_G22F_ (22x58mm) 31<br>750 Vdc 5 to 30 FWK-_A20F (20x127mm) 32<br>750 Vdc 35-60 FWK-_A25F (25x146mm)<br>1000 Vac/800 Vdc 20 to 30 FWJ (14x67mm) 33<br>1200 Vac/1000 Vdc 20 to 30 FWL (20x127mm) 34<br>1400-2000 Vac/1000 Vdc 2 to 15 FWS (20x127mm) 35<br>J70032 700 V panel mount block for FWP 14x51mm fuses<br>JM70100 700 V DIN-Rail/panel mount modular blocks for FWP 22x58mm fuses 36<br>Accessories CHM modular holders for FWA and FWC 10x38mm fuses<br>CH14 modular holders for FWX, FWH and FWP 14x51mm fuses 37<br>CH22 modular holders for FWP 22x58mm fuses<br>Square body<br>690-700 Vac/ 700 Vdc 10 to 400 170M — size 000 and 00 38-39<br>690-700 Vac 40 to 2000 170M — size 1* to 3 40-41<br>DIN 43653 1000 Vac 20 to 315 170M — size 00 42<br>1000 Vac 50 to 1400 170M — size 1* to 3 43-44<br>1250-1300 Vac 50 to 1400 170M — size 1* to 3 45-46<br>690 Vac 10 to 800 170M — size 00 to 3 47-48<br>170M — size 000 to 3<br>DIN 43620 690-700 Vac 10 to 1600 49-50<br>dual indicator<br>1000 Vac 20 to 225 170M — size 00 51<br>French style 690-700 Vac 40 to 1600 170M — size 1* to 3 52-53<br>690-700 Vac 40 to 2000 170M — size 1* to 3 54-55<br>US style 1000 Vac 50 to 1400 170M — size 1* to 3 56-57<br>1250-1300 Vac 50 to 1400 170M — size 1* to 3 58-59<br>690 Vac 25 to 400 170M — size 00 60<br>690-700 Vac 40 to 2000 170M — size 1* to 3 61-62<br>1000 Vac 50 to 1400 170M — size 1* to 3 63-64<br>1250-1300 Vac 50 to 1400 170M — size 1* to 3 65-66<br>690-700 Vac 1000 to 4000 170M — size 4 67-68<br>Flush-end contact 1000 Vac 1000 to 3000 170M — size 4 69<br>1250 Vac 800 to 2500 170M — size 4 70<br>660 Vac 1000 to 4000 170M — size 23 71-72<br>1250 Vac 630 to 2800 170M — size 23 73<br>690 Vac 2000 to 7500 170M — size 24 74<br>1000 Vac 2000 to 5000 170M — size 24 75<br>Fixed center blocks for DIN 43653 fuses 76-77<br>Accessories Indicators 78<br>Microswitches 78<br>IGBT fuses<br>750-800 Vdc 25 to 630 170M — size 000 and 230 79-80<br>Fuses<br>1000 Vdc 25 to 500 170M — size 000 and 230 81-82<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
4-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## CHSF — UL compact high speed fuse
500 Vac/dc (UL), 50 to 400 A
500 Vac/dc (UL), 50 to 400 A **2011/65/EU** Bussmann[™] series compact high speed fuses feature space-saving eS case sizes for protecting semiconductor devices up to 500 Vac/dc in ratings from 50 to 400 amps.
Ratings
- Volts
- 500 Vac/dc (UL)
- Amps 50-400 A
- Interrupting rating
- Max AC – 200 kA
- Min AC 400%
- Max DC – 50 kA
- Min DC 800%
Operating class aR
Agency information
- UL Recognized, Guide JFHR2, File E56412
- CSA Component Acceptance, Class 1422-30, File 53787
- IEC aR (self certified)
- RoHS compliant
> • CE
## Features
- Requires up to 48% less enclosure space to help reduce the overall assembly size
- Innovative design allows for a significantly smaller package without compromising heat rise performance, preventing extensive equipment redesign
- Global acceptance with UL, CSA, IEC and RoHS for products sold worldwide
- Bolt-on design provides design flexibility for installation in fuse blocks or direct mounting on busbars
- Meets JASO D622 spec for thermal shock, humidity, and vibration
- Superior current cycling performance helps withstand demanding applications
Recommended fuse blocks
Up to 100 amps
|Catalogno.<br>AWG wire size<br>Stud size<br>~~Pe~~|
|---|
|BH-0111<br>14-2/0 Cu<br>1/4-20|
|BH-0112<br>14-2/0 Cu<br>5/16-18|
|BH-0121<br>(2) 14-1/0 Cu<br>1/4-20|
|BH-0122<br>(2) 14-1/0 Cu<br>5/16-18<br>1BS101<br>14-2/0 Cu<br>1/4-20 x 1/2<br>See data sheet no. 1200 (BH-01_) and 1206 (1BS101) for details.|
Up to 400 amps
~~Pg~~ Catalog no. AWG wire size Stud size BH-1131 6-250kcmil Cu 1/4-20 BH-1132 6-250kcmil Cu 5/16-18 1BS102 6-250kcmil Cu 1/4-20 x 1/2
See data sheet no. 1201 (BH-11_) and 1207 (1BS102) for details.
|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|Catalogno.<br>Amps<br>AC/DC I2t (A2s)<br>pre-arcing<br>AC* I2t (A2s)<br>total clear<br>DC** I2t (A2s)<br>total clear<br>Watts loss /percent of rated current<br>@ 80%<br>@ 50%<br>~~ee~~|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|CHSF-50|50|304|1875|||||||935||||3.8|||||||1.3|||
|CHSF-60|60|438|2700|||||||1346||||4.5|||||||1.5|||
|CHSF-70|70|596|3675|||||||1833||||5.3|||||||1.8|||
|CHSF-80|80|778|4800|||||||2394||||6.1|||||||2.0|||
|CHSF-100|100|1216|7500|||||||3740||||7.6|||||||2.5|||
|CHSF-125|125|2042|12,721|||||||6465|||12.0||||||||3.6|||
|CHSF-150|150|2941|18,318|||||||9309|||14.3||||||||4.3|||
|CHSF-175|175|4003|24,933|||||||12,671|||16.7||||||||5.1|||
|CHSF-200|200|5228|32,566|||||||16,550|||19.1||||||||5.8|||
|CHSF-225|225|6835|48,028|||||||21,278|||26.1||||||||7.0|||
|CHSF-250|250|8438|59,293|||||||26,270|||29.0||||||||7.8|||
|CHSF-300|300|12,151|85, 382|||||||37,828|||34.8||||||||9.4|||
|CHSF-350|350|16,539|116,215|||||||51,488|||40.6|||||||10.9||||
|CHSF-400<br>400<br>21,603<br>151,791<br>67,250<br>46.4<br>* @ 200 kA/500 Vac.<br>** @ 50 kA/500 Vdc.<br>Dimensions — mm<br>Amps<br>A<br>B<br>C<br>D1<br>D2<br>E<br>F<br>G<br>H<br>50-100<br>81<br>20<br>40<br>61<br>57<br>8.7<br>16<br>7.7<br>3.2<br>125-200<br>92<br>25<br>53<br>77<br>68<br>8.7<br>19<br>7.8<br>3.2<br>225-400<br>92<br>30<br>53<br>74<br>68<br>8.7<br>25<br>9.0<br>4.8<br>A<br>C<br>E<br>F<br>G<br>D1<br>D2<br>~~t=——~~<br>~~anas:~~|||||||||||||||||B<br>H|||12.5||||
Data sheet no. 10414
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-3
**4 — High speed fuses** ~~TR~~ 2m DFJ — UL Class J full range high speed fuse
## 600 Vac/450 Vdc (UL), 1 to 600 A
UL Class J high speed, full range current-limiting fuses provide maximum protection for AC and DC drives and controllers. The UL Class J Bussmann series DFJ fuse has the lowest I[2] t of any branch circuit fuse to protect power semiconductor devices that utilize diodes, GTOs, SCRs and SSRs. The DFJ fuse combines the performance of high speed fuses in a full range Class J branch circuit package, allowing the use of readily available Class J fuse blocks, holders and switches. The DFJ uses standard Class J holders and blocks. See section 8 for available catalog numbers.
## Ratings
- Volts
**==> picture [531 x 508] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|•|600 Vac (UL)|I|[2]|t (A|[2]|Sec) @ 600 Vac/100 kA|
|Catalog|
|•|450 Vdc (UL 15-600 A)|See|no.|Amps|Pre-arc|Clearing|Watts loss*|
|Amps 1-600 A|DFJ-1|1|—|—|—|
|IR|DFJ-2|2|—|—|—|
|•|200 kA RMS Sym.|DFJ-3|3|—|—|—|
|•|100 kA DC|DFJ-4|4|—|—|—|
|DFJ-5|5|—|—|—|
|Operating class gR|
|DFJ-6|6|—|—|—|
|Agency information|DFJ-8|8|—|—|—|
|DFJ-10|10|—|—|—|
|UL Listed, Std 248-8, Class J, Guide JDDZ, File E4273|DFJ-12|12|—|—|—|
|CSA Certified, C22-2 No 248.8, Class 1422-02, File 53787|
|DFJ-15|15|4|110|4.1|
|CE|DFJ-17.5|17.5|—|—|—|
|Dimensions — in|DFJ-20|20|8|365|4.0|
|2.25|2.38|DFJ-25|25|12|610|4.9|
|0.50|0.81|0.63|1.06|DFJ-30|30|20|1000|5.5|
|Pa|1 to 30A|te|||te|35 to 60A|OO|DFJ-35|35|55|1100|6.8|
|DFJ-40|40|90|1900|8.6|
|4.63|
|3.63|DFJ-50|50|140|2800|8.7|
|2.63|0.75|1.13|
|DFJ-60|60|290|6000|8.5|
|0.43|1|0.28|oF|.13|OO|DFJ-70|70|450|3100|12|
|70 to 100A|
|DFJ-80|80|650|4600|13|
|5.75|DFJ-90|90|1010|7200|13|
|4.38|3.0|0.28 1.13|DFJ-100|100|1460|10,500|13|
|1.63|DFJ-110|110|1710|9500|17|
|li|0.43|g:|1.38|0.19|OT|DFJ-125|125|3580|20,000|15|
|110 to 200A|
|DFJ-150|150|5080|28,000|19|
|7.13|DFJ-175|175|6310|35,000|23|
|5.25|
|3.38|0.41|DFJ-200|200|9850|54,500|24|
|1.63|2.11|DFJ-225|225|11,420|51,000|29|
|0.58|1.88|0.25|DFJ-250|250|17,000|74,500|30|
|ike:|OO|
|225 to 400A|
|DFJ-300|300|23,500|103,000|36|
|8.0|DFJ-350|350|38,800|170,000|39|
|6.0|
|3.75|0.53|DFJ-400|400|62,200|272,000|40|
|2|2.5|DFJ-450|450|44,600|270,000|56|
|DFJ-500|500|79,500|480,000|52|
|0.74|2.13|O|n|0.38|TT|
|450 to 600A|DFJ-600|600|138,000|830,000|57|
**----- End of picture text -----**<br>
- Amps 1-600 A
- IR
## Operating class gR
## Agency information
- UL Listed, Std 248-8, Class J, Guide JDDZ, File E4273
- CSA Certified, C22-2 No 248.8, Class 1422-02, File 53787
## • CE
## Dimensions — in
† Watts loss at rated current.
Data sheet no. 1048
Eaton.com/bussmannseries
4-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## FWA — North American
130 Vac/dc (UL), 1000 to 4000 A
North American style flush-end high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters.
## Ratings
- Volts 130 Vac/dc
- Amps 1000-4000 A
- IR
- 200 kA RMS Sym at 130 Vac
- 50 kA at 130 Vdc
## Agency information
- UL Recognized, JFHR2, E91958 on 1000-2000 A fuses
> • CE
|Rated voltage|Rated current (amps)|Pre-arcing|I²t (A²s)<br>Clearingat 130 Vac|Watts loss (W)†|Catalogno.|
|---|---|---|---|---|---|
||1000|170,000|460,000|60|FWA-1000AH|
||1200|270,000|730,000|70|FWA-1200AH|
||1500|520,000|1,400,000|78|FWA-1500AH|
|130 Vac/dc (UL)|2000|860,000|2,400,000|108|FWA-2000AH|
||2500|1,500,000|4,100,000|130|FWA-2500AH|
||3000|2,100,000|5,700,000|150|FWA-3000AH|
||4000|3,400,000|9,200,000|257|FWA-4000AH|
† Watts loss at rated current.
## Dimensions — in
**==> picture [161 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
1000-3000 A 4000 A<br>**----- End of picture text -----**<br>
~~[~~ Amp range B C D Thread / depth 1000 to 2000 2.0 1.0 — 3/8-24 x 1/2” UNF 2500 to 3000 3.0 1.5 — 1/2-20 x 1/2” UNF 4000 3.5 1.5 1.5 1/2-20 x 1/2” UNF 1” = 25.4mm
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 720001, 5785301
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-5
## **4 — High speed fuses** ~~TO~~ est FWA — North American
150 Vac/dc (UL), 70 to 1000 A
North American style bolted tag high speed fuses used for the protection of DC common bus, DC drives, power converters / rectifiers and reduced rated voltage starters.
## Ratings
- Volts
- 150 Vac/dc (UL)
- 80 Vdc 1000 A only
- Amps 70-1000 A
- IR
- 100 kA RMS Sym. (70-400 A)
- 200 kA RMS Sym. (450-1000 A)
- 20 kA at 150 Vdc (70-800 A)
- 100 kA at 80 Vdc (70-1000 A)
## Agency information
- UL Recognized JFHR2, E91958
> • CE
|Rated voltage<br>Rated current (amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 150 Vac<br>70<br>470<br>4000<br>6.9<br>FWA-70B<br>~~eee~~|Rated voltage<br>Rated current (amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 150 Vac<br>70<br>470<br>4000<br>6.9<br>FWA-70B<br>~~eee~~|Rated voltage<br>Rated current (amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 150 Vac<br>70<br>470<br>4000<br>6.9<br>FWA-70B<br>~~eee~~|Rated voltage<br>Rated current (amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 150 Vac<br>70<br>470<br>4000<br>6.9<br>FWA-70B<br>~~eee~~|
|---|---|---|---|
||80|670<br>6000|7.7<br>FWA-80B|
||100|1200<br>12,000|9.0<br>FWA-100B|
||125|1870<br>18,000|11.2<br>FWA-125B|
||150|2700<br>26,000|13.5<br>FWA-150B|
||200|4780<br>45,000|17.6<br>FWA-200B|
|150 Vac/dc (UL)|250<br>300|7470<br>70,000<br>10,760<br>100,000|22.5<br>FWA-250B<br>27.0<br>FWA-300B|
||350|15,700<br>140,000|30.6<br>FWA-350B|
||400|20,300<br>180,000|35.2<br>FWA-400B|
||500|39,000<br>120,000|35.0<br>FWA-500A|
||600|46,000<br>140,000|47.0<br>FWA-600A|
||700|75,000<br>220,000|49.0<br>FWA-700A|
||800|92,000<br>280,000|58.0<br>FWA-800A|
|80 Vdc|1000|170,000<br>510,000|60.0<br>FWA-1000A|
- Watts loss at rated current.
## Dimensions — mm
**==> picture [534 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
11.24 24.21 Ø 88.3<br>31.8<br>19.4<br>6.35<br>8.95 19.05<br>Te ® a} ,<br>25.4<br>28.36 3.24<br>49.06<br>65.75 11.0 48.7 38.5 Ø<br>65.5<br>SITS) Cp Hel eh ©)<br>70-400 A 500-1000 A<br>For details on electrical characteristics, contact Application Engineering and ask for data sheets: 720002, 5785310<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
4-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## FWX — North American
250 Vac/dc (UL), 35 to 2500 A
North American style bolted tags and flush-end high speed fuses for the protection of DC common bus, DC drives, power converters/ rectifiers and reduced rated voltage starters.
## Ratings
- Volts 250 Vac/dc (UL)
- Amps 35-2500 A
- IR
**==> picture [546 x 476] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||Rated|I²t (A²s)|Watts|
|•|200 kA RMS Sym.|Rated|current|Pre-|Clearing|loss|
|•|20 kA at 250 Vdc (35-800 A)|voltage|(amps)|arcing|at 250 Vac|(W)†|Catalog no.|
|35|50|230|4.2|FWX-35A|
|Agency information|40|60|310|5.2|FWX-40A|
|45|80|390|5.7|FWX-45A|
|•|UL Recognized, JFHR2, E56412|
|50|100|520|6.0|FWX-50A|
|•|CSA Class 1422-30, (53787) on 35-800 A fuses (20 kA IR at 250|60|140|740|8.1|FWX-60A|
|Vdc)|
|70|330|1400|7.2|FWX-70A|
|•|CE|
|80|430|1850|8.1|FWX-80A|
|Dimensions — in|90|570|2450|9.0|FWX-90A|
|100|740|3150|10.0|FWX-100A|
|A|125|1130|4850|12.5|FWX-125A|
|H|DE|150|1620|6950|15.7|FWX-150A|
|C|
|175|2170|9300|18.5|FWX-175A|
|B|G|F|200|2790|12,000|22.0|FWX-200A|
|J|225|3210|14,700|24.0|FWX-225A|
|250 Vac/dc|250|3960|18,100|27.0|FWX-250A|
|35-800 A|(UL)|275|4720|21,600|31.0|FWX-275A|
|300|6000|27,300|32.0|FWX-300A|
|350|10,600|48,600|39.0|FWX-350A|
|400|14,500|66,100|44.0|FWX-400A|
|A|A|
|450|22,100|101,000|49.0|FWX-450A|
|500|28,000|128,000|54.0|FWX-500A|
|i”|7”|
|$<|600|41,100|188,000|62.0|—|FWX-600A|
|D|700|48,800|190,000|72.0|FWX-700A|
|800|59,000|230,000|84.0|FWX-800A|
|*F\2|B|C|*|B|fe|Ns|C|a|1000|44,000|360,000|100.0|FWX-1000AH|
|1200|92,000|750,000|103.0|FWX-1200AH|
|(on|$=|1500|120,000|880,000|140.0|FWX-1500AH|
|1000-1200 A|1500-2500 A|1600|160,000|1,200,000|140.0|FWX-1600AH|
|2000|320,000|2,300,000|151.0|FWX-2000AH|
|Amp|Thread|2500|670,000|4,700,000|163.0|FWX-2500AH|
|————t|range|A|B|C|D|E|F|G|H|J|/ depth|† Watts loss at rated current.|
|35-60|3.19|0.81|1.59|2.59|2.25|0.34|0.63|0.13|0.52|—|
|70-200|3.13|1.22|1.59|2.44|2.19|0.34|1.00|0.19|0.47|—|
|225-600|3.84|1.50|1.59|2.94|2.25|0.41|1.00|0.25|0.75|—|
|700-800|3.84|2.00|1.59|3.03|2.28|0.41|1.50|0.25|0.78|—|
|1000-1200|2.59|3.00|1.50|—|—|—|—|—|—|3/8-24|
|1500-2500|2.59|3.50|1.50|1.50|—|—|—|—|—|x 1/2”|
|UNF|
**----- End of picture text -----**<br>
1” = 25.4mm
For details on electrical characteristics, contact Application Engineering and ask for data sheets:720005, 359 (35-800 A), 5785299 (100-2500 A)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-7
## **4 — High speed fuses**
## FWH — North American
## 500 Vac/dc (UL), 35 to 1600 A
North American style bolted tags high speed fuses, for the protection of DC common bus, power converters/rectifiers and reduced rated voltage starters.
## Ratings
- Volts
- 500 Vac (UL)
- 500 Vdc (35-800 A only)
- Amps 35-1600 A
- IR
- 200 kA RMS Sym.
- 50 kA at 500 Vdc
## Agency information
- UL Recognized, JFHR2, E91958, FWH-_B (35-200 A) and FWH-_A (1000 and 1200 A), JFHR2, E56412 FWH-_A (225-800 A)
- CSA Class 1422-30, File 53787 (35-1600 A)
> • CE
Dimensions — in
|||||||A|||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||D|||||||||||||||||||
|E<br>C<br>F<br>J<br>G<br>35-1200 A<br>elie<br>le|||||||||||||||||B|||||H|||
|||||||10.22|||||||||||||||||||
|||||||8.71<br>8.97|||||||||||||||||||
|||||||6.22|||||||||||||||||||
|||||||5.22|||||||||||||||||||
|se]||||||3.22|4.25 Ø<br>~~[S~~a~~h~~||||||||||||||||||
||||||||||||||||1.625|1.75|3.5||||||||
||||||||||||||||||||||||||
||||||||||||||||||||||||||
|0.625<br>1400-1600 A|||||||||||||||||0.75<br>—||||||||
|Amprange<br>A<br>B<br>C<br>D<br>E<br>F<br>G<br>H<br>J<br>35-60<br>3.19<br>0.81<br>1.59<br>2.54<br>2.19<br>0.34<br>0.72<br>0.13<br>0.52<br>70-100<br>3.62<br>0.95<br>1.74<br>2.85<br>2.81<br>0.35<br>0.75<br>0.13<br>0.38<br>~~ee~~|||||||||||||||||||||||||
|125-200||||||3.62<br>1.16|1.84|2.89||||||2.77|||0.34|1.00||||0.19||0.41|
|225-400||||||4.34<br>1.50|2.09|3.44||||||2.75|||0.41|1.00||||0.25||0.75|
|450-600||||||4.34<br>2.00|2.09|3.53||||||2.78|||0.41|1.50||||0.25||0.78|
|700-800||||||6.34<br>2.50|2.09|4.97||||||3.44|||0.53|2.00||||0.38||1.30|
|1000-1200||||||6.97<br>3.00|3.22|5.47||||||4.48|||0.62|2.38||||0.44||1.12|
|1400-1600|||||||||Refer to drawin||||||Refer to drawing||||||||||
|||I²t (A²s)||
|---|---|---|---|
|Rated voltage|Rated<br>current<br>(amps)<br>35|Pre-<br>arcing<br>Clearing<br>at 250<br>Vac<br>34<br>150|Watts<br>loss<br>(W)†<br>Catalogno.<br>8.0<br>FWH-35B|
||40|76<br>320|7.5<br>FWH-40B|
||45|105<br>450|7.5<br>FWH-45B|
||50|135<br>670|7.5<br>FWH-50B|
||60|210<br>900|9.9<br>FWH-60B|
||70|210<br>900|10.6<br>FWH-70B|
|500 Vac/dc (UL)|80|305<br>1400|12.7<br>FWH-80B|
||90|360<br>1600|15.0<br>FWH-90B|
||100|475<br>2000|17.0<br>FWH-100B|
|125<br>800<br>3500<br>25.0<br>FWH-125B<br>150<br>1100<br>4600<br>30.0<br>FWH-150B<br>175<br>1450<br>6200<br>35.0<br>FWH-175B<br>200<br>1900<br>8500<br>40.0<br>FWH-200B<br>225<br>4600<br>23,300<br>39.0<br>FWH-225A<br>~~——~~<br>~~re~~||||
||250|6300<br>32,200|41.0<br>FWH-250A|
||275|7900<br>40,300|46.0<br>FWH-275A|
||300|9800<br>49,800|51.0<br>FWH-300A|
|500 Vac/dc (UL)|325<br>13,700<br>63,800<br>53.0<br>FWH-325A<br>350<br>14,500<br>72,900<br>58.0<br>FWH-350A<br>400<br>19,200<br>96,700<br>65.0<br>FWH-400A<br>450<br>24,700<br>127,000<br>74.0<br>FWH-450A<br>~~ee~~|||
||500|29,200<br>149,000|84.0<br>FWH-500A|
||600<br>41,300<br>206,000<br>108.0<br>FWH-600A<br>700<br>55,000<br>298,000<br>120.0<br>FWH-700A<br>800<br>76,200<br>409,000<br>129.0<br>FWH-800A<br>~~ee~~|||
||1000|92,000<br>450,000|145.0<br>FWH-1000A|
|500 Vac (UL)|1200<br>1400|122,000<br>600,000<br>200,000<br>1,000,000|180.0<br>FWH-1200A<br>210.0<br>FWH-1400A|
||1600|290,000<br>1,400,000|230.0<br>FWH-1600A|
- Watts loss at rated current.
1” = 25.4mm
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 720007, 360 (225-800 A), 5785304 (35-200 A, 1000-1600 A)
Eaton.com/bussmannseries
4-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## KAC — North American
## 600 Vac (UL), 1 to 1000 A
North American style bolted tags high speed fuses. These fuses are supplied as replacements only. For new installations, Eaton recommends the 700 V FWP. See page 4-11.
## Ratings
- Volts 600 Vac
- Amps 1-1000 A
- IR 200 kA RMS Sym.
Agency information
- UL Recognized, JFHR2, E56413 (1-600 A only)
> • CE
~~ee~~ Rated voltage Rated current (amps) Catalog no. 1 KAC-1 Dimensions — in 2 KAC-2 3 KAC-3 4 KAC-4 ~~TT~~ 5 KAC-5 _ ~~a~~ x 6 KAC-6 7 KAC-7 8 KAC-8 ~~OO~~ ‘eal 9 KAC-9 1-30 A and 450-1000 A 10 KAC-10 12 KAC-12 A 15 KAC-15 B2 17.5 KAC-17.5 B3 20 KAC-20 C G ~~ee~~ 25 KAC-25 A 4 er ~~oe~~ 30 KAC-30 iw, D E F 35 KAC-35 40 KAC-40 ~~Se~~ 45 KAC-45 ~~f1~~ H 1 50 KAC-50 35-400 A 600 Vac (UL) 60 KAC-60 70 KAC-70 Amp 80 KAC-80 rangegee A B1 B2 B3 C D E F G H ~~—_M-~~ 90 KAC-90 1-30 2.88 ~~mi~~ 2.50 — — ~~i~~ 1.88 0.41 ~~ae~~ — 0.56 0.06 100 KAC-100 35-60 4.38 — 3.75 3.50 2.75 0.63 0.34 0.81 0.09 110 KAC-110 70-100 5.00 — 4.06 3.66 2.75 0.75 0.41 1.00 0.13 125 KAC-125 110-200 5.14 — 4.39 3.77 2.91 1.00 0.41 1.50 0.19 150 KAC-150
**==> picture [262 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|35-400 A|
|Amp|
|rangegee|A|B1|B2|B3|C|D|E|F|G|H|
|1-30|2.88|mi|2.50|—|—|i|1.88|0.41|ae|—|0.56|0.06|0.26|
|35-60|4.38|—|3.75|3.50|2.75|0.63|0.34|0.81|0.09|0.47|
|70-100|5.00|—|4.06|3.66|2.75|0.75|0.41|1.00|0.13|0.61|
|110-200|5.14|—|4.39|3.77|2.91|1.00|0.41|1.50|0.19|0.72|
|225-400|6.18|—|4.82|4.57|3.00|1.63|0.56|2.00|0.25|0.69|
|450-800|6.25|4.75|—|3.06|2.00|—|2.50|0.25|0.56|
|1000|7.25|4.75|—|3.06|2.75|—|3.50|0.38|0.56|
**----- End of picture text -----**<br>
**==> picture [80 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|175|KAC-175|
|200|KAC-200|
|225|KAC-225|
|250|KAC-250|
|300|KAC-300|
|350|KAC-350|
|400|KAC-400|
|450|KAC-450|
|500|KAC-500|
|600|KAC-600|
|700|KAC-700|
|800|KAC-800|
|1000|KAC-1000|
**----- End of picture text -----**<br>
1” = 25.4mm
Data sheet no. 720009
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-9
## **4 — High speed fuses**
## KBC — North American
600 Vac (UL), 35 to 800 A
North American style bolted tags and flush-end high speed fuses. These fuses are supplied as replacements only. For new installations, Eaton recommends the 700 V FWP fuses. See page 4-11.
## Ratings
- Volts 600 Vac (UL)
- Amps 35-800 A
- IR 200 kA RMS Sym.
## Agency information
- UL Recognized, JFHR2, E56412 (35-600 A only)
## • CE
**==> picture [525 x 294] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Rated voltage|Rated current (amps)|Catalog no.|Dimensions — in|
|35|KBC-35|A|
|40|KBC-40|B|
|45|KBC-45|C|
|D|H|
|50|KBC-50|
|—______—_—|<< —,|ni|
|60|KBC-60|
|——|>|
|70|KBC-70|F|E|G|
|80|KBC-80|Pn|
|re|an|
|90|KBC-90|as|J|yx|
|re|[~]|
|100|KBC-100|35-60 and 110-600 A|
|110|KBC-110|
|125|KBC-125|
|600 Vac (UL)|150|KBC-150|
|175|KBC-175|
|200|KBC-200|~|KZ|
|225|KBC-225|
|250|KBC-250|Yy|ys|
|300|KBC-300|
|70-100 A|
|350|KBC-350|
|400|KBC-400|4|
|1/2-24 x 1/2”|
|450|KBC-450|3.75|
|500|KBC-500|
|0.75|
|600|KBC-600|
|800|KBC-800|
|re|T|||||©|:[-[-|
**----- End of picture text -----**<br>
**==> picture [263 x 247] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|4|
|1/2-24 x 1/2”|
|3.75|
|T|||||2.5|||2.859|©|:[-[-|0.75|
|0.75|
|L||2|an|
|800 A|
|Rated current|
|as|(amps)|A|B|C|D|E|F|G|H|J|
|35-60|4.38|3.75|3.50|2.75|0.34|0.63|0.81|0.09|0.47|
|70-100|Refer to drawing|
|110-200|4.41|3.72|3.59|2.91|0.31|0.88|1.22|0.19|0.38|
|225-400|5.13|4.19|3.56|2.91|0.41|1.00|1.50|0.25|0.72|
|450-600|5.13|4.39|3.69|2.88|0.41|1.50|2.00|0.25|0.76|
|800|Refer to drawing|
**----- End of picture text -----**<br>
1” = 25.4mm
Data sheet no. 720010
Eaton.com/bussmannseries
4-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## FWP — North American
700 Vac/dc (UL), 5 to 1200 A
North American style bolted tags high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers, reduced rated voltage starters.
## Ratings
- Volts 700 Vac/dc (UL)
- Amps 5-1200 A
- IR
- 200 kA RMS Sym.
- 50 kA at 700 Vdc (Type A)
- 50 kA at 500 Vdc (Type B)
## Agency information
- UL Recognized, JFHR2, E91958 FWP-_B (5-100 A, 700-1200 A), JFHR2, E56412 FWP-_A (125-600 A)
- CSA Class 1422-30, (53787) on 5-800 A
- CE
|||I²t (A²s)||
|---|---|---|---|
|Rated voltage|Rated current (amps)|Pre-arcing<br>Clearingat 700 Vac|Watts loss (W)†<br>Catalogno.|
||5|1.6<br>11|1.5<br>FWP-5B|
||10|3.6<br>22|4.0<br>FWP-10B|
||15|10.0<br>70|5.5<br>FWP-15B|
||20|26.0<br>180|6.0<br>FWP-20B|
||25|44.0<br>320|7.0<br>FWP-25B|
||30|58.0<br>450|9.0<br>FWP-30B|
||35|34.0<br>160|12.0<br>FWP-35B|
||40|76.0<br>320|12.0<br>FWP-40B|
||50|135.0<br>600|12.0<br>FWP-50B|
||60|210.0<br>950|15.5<br>FWP-60B|
||70|305.0<br>2000|18.0<br>FWP-70B|
||80|360.0<br>2400|21.0<br>FWP-80B|
||90|415.0<br>2700|25.0<br>FWP-90B|
||100|540.0<br>3500|27.0<br>FWP-100B|
||125|1800.0<br>7300|28.0<br>FWP-125A|
|700 Vac/dc (UL)|150|2900.0<br>11,700|32.0<br>FWP-150A|
||175|4200.0<br>16,700|35.0<br>FWP-175A|
||200|5500.0<br>22,000|43.0<br>FWP-200A|
||225|7700.0<br>31,300|45.0<br>FWP-225A|
||250|10,500.0<br>42,500|48.0<br>FWP-250A|
||300|17,600.0<br>71,200|58.0<br>FWP-300A|
||350|23,700.0<br>95,600|65.0<br>FWP-350A|
||400|31,000.0<br>125,000|78.0<br>FWP-400A|
||450|36,400.0<br>137,000|94.0<br>FWP-450A|
||500|45,200.0<br>170,000|107.0<br>FWP-500A|
||600|66,700.0<br>250,000|122.0<br>FWP-600A|
||700|54,000.0<br>300,000|125.0<br>FWP-700A|
||800|78,000.0<br>450,000|140.0<br>FWP-800A|
||900|91,500.0<br>530,000|150.0<br>FWP-900A|
||1000|120,000.0<br>600,000|170.0<br>FWP-1000A|
||1200|195,000.0<br>1,100,000|190.0<br>FWP-1200A|
- Watts loss at rated current.
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 720012, 5785316 (5-30 A), 361 (125-600 A), 5785308 (35-100 A, 700-1200 A)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-11
**4 — High speed fuses**
## FWP — North American
700 Vac/dc (UL), 5 to 1200 A
Dimensions — in
**==> picture [263 x 219] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>D<br>E<br>C H<br>G F B<br>J<br>5-800 A<br>Amp range A B C D E F G H J<br>5-30 2.87 0.56 1.86 2.48 2.48 0.25 0.41 0.06 0.25<br>35-60 4.38 0.81 2.75 3.71 3.31 0.34 0.73 0.13 0.54<br>70-100 4.41 0.95 2.59 3.63 3.56 0.34 0.75 0.13 0.38<br>125-200 5.09 1.50 2.84 4.19 3.5 0.41 1.00 0.25 0.75<br>225-400 5.09 2.00 2.84 4.28 3.53 0.41 1.50 0.25 0.78<br>450-600 7.09 2.50 2.84 5.72 4.19 0.53 2.00 0.38 1.30<br>700-800 6.63 2.00 2.76 5.56 5.06 0.63 1.50 0.25 0.88<br>900-1000<br>Refer to drawing<br>1200<br>**----- End of picture text -----**<br>
1” = 25.4mm
**==> picture [334 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.49<br>1.03<br>1.38 0.625 2.75<br>3.85<br>3.5<br>5.15<br>5.97<br>7.59<br>**----- End of picture text -----**<br>
900-1000 A -mm
**==> picture [352 x 165] intentionally omitted <==**
**----- Start of picture text -----**<br>
10.87<br>9.59<br>9.34<br>6.84<br>5.84<br>4.25 Ø<br>3.84<br>1.62 1.75 3.5<br>0.62<br>0.75<br>**----- End of picture text -----**<br>
1200 A -mm
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 720012, 5785316 (5-30 A), 361 (125-600 A), 5785308 (35-100 A, 700-1200 A)
Eaton.com/bussmannseries
4-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## FWJ — North American
1000 Vac /800 Vdc (UL), 35 to 2000 A
North American style bolted tags high speed fuses for the protection of DC common bus, DC drives power converters/rectifiers, reduced rated voltage starters and high voltage traction inverters.
## Ratings
- Volts
- 1000 Vac
- 800 Vdc
- Amps 35-2000 A
- IR
- 25 kA RMS Sym. (35-200 A)
- 100 kA RMS Sym. (250-2000 A)
- 50 kA at 800 Vdc (35-200 A and 450-600 A)
## Agency information
- UL Recognized, JFHR8, E91958 on 50-600 A only
- CE
|Rated<br>voltage|Rated<br>current<br>(amps)<br>35|I²t (A²s)<br>Pre-arcing<br>Clearing at<br>1000 Vac<br>210<br>2000|Watts<br>loss<br>(W)†<br>Catalogno.<br>7<br>FWJ-35A||Dimensions — in|Dimensions — in|Dimensions — in|||A<br>E<br>D<br>C|||||||H||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||40<br>300<br>2500<br>8<br>FWJ-40A<br>50<br>470<br>3500<br>10<br>FWJ-50A<br>60<br>670<br>5000<br>11<br>FWJ-60A<br>70<br>1100<br>6900<br>12<br>FWJ-70A<br>80<br>1550<br>9700<br>13<br>FWJ-80A<br>F<br>J<br>G<br>B<br>~~——————~~ of<br>~~a~~<br>~~——~~<br>=||||||||||||||||||
||90<br>100|1900<br>12,000<br>2800<br>17,500|14<br>FWJ-90A<br>15<br>FWJ-100A||Amp<br>range|A|||B|C|D|E||F|G||H|J|
||125|4800<br>35,000|16<br>FWJ-125A||35-60|5.00|||0.94|3.11|4.24|4.18||0.35|0.75||0.13|0.38|
||150|6300<br>45,000|25<br>FWJ-150A||70-100|4.93|||1.13|3.09|4.27|4.16||0.35|1.00||0.19|0.41|
||175|7500<br>65,000|30<br>FWJ-175A||125-200|5.69|||1.53|3.26|4.80|4.06||0.45|1.00||0.25|0.82|
|1000 Vac/<br>800 Vdc<br>(UL)|200<br>250<br>300<br>350<br>400|11,700<br>80,000<br>16,000<br>112,000<br>23,500<br>164,000<br>33,000<br>231,000<br>47,000<br>330,000|32<br>FWJ-200A<br>50<br>FWJ-250A<br>56<br>FWJ-300A<br>62<br>FWJ-350A<br>67<br>FWJ-400A||250-400<br>5.77<br>500-600<br>7.20<br>800-2000<br>6.81<br>1” = 25.4mm||||2.00<br>2.50<br>3.50|3.50<br>3.47<br>3.31|4.81<br>5.98<br>5.47|4.15<br>4.71<br>4.96||0.43<br>0.56<br>0.63|1.50<br>2.00<br>2.75||0.25<br>0.38<br>0.50|0.76<br>1.20<br>0.88|
||500|39,500<br>329,000|95<br>FWJ-500A||||||||||||||||
||600|61,000<br>520,000|105<br>FWJ-600A||||||||||||||||
||800|87,000<br>500,000|182<br>FWJ-800A||||||||||||||||
||1000|190,000<br>1,100,000|206<br>FWJ-1000A||||||||||||||||
||1200|370,000<br>2,100,000|240<br>FWJ-1200A||||||||||||||||
||1400|470,000<br>2,700,000|248<br>FWJ-1400A||||||||||||||||
||1600|700,000<br>4,000,000|267<br>FWJ-1600A||||||||||||||||
||1800|925,000<br>5,300,000|239<br>FWJ-1800A||||||||||||||||
||2000|1,330,000<br>7,600,000|244<br>FWJ-2000A||||||||||||||||
- Watts loss at rated current.
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 720027, 5785303 (35-600 A), 5785309 (800-2000 A),
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-13
## **4 — High speed fuses**
## North American Accessories
## Modular fuse blocks
BH modular type
Bussmann series line of fuse blocks provides the user with design and manufacturing flexibility. Two identical half blocks make up a modular assembly that can be panel mounted any distance apart to accommodate any length fuse. C5268 stud type _ hee <a = gS |
BH modular blocks provide a wide range of mounting configurations for Bussmann series high speed semiconductors fuses. BH fuse blocks have a short-circuit current rating up to 200 kA RMS Sym.
The simpler design is the C5268 modular fuse block. With this design, the fuse terminal and cable (with termination) are mounted on the same stud, minimizing installation labor. The stud type block is available in the configurations shown in the table below.
|The simpler design is the C5268 modular fuse block. With this<br>design, the fuse terminal and cable (with termination) are mounted<br>on the same stud, minimizing installation labor. The stud type block<br>is available in the configurations shown in the table below.|The simpler design is the C5268 modular fuse block. With this<br>design, the fuse terminal and cable (with termination) are mounted<br>on the same stud, minimizing installation labor. The stud type block<br>is available in the configurations shown in the table below.|
|---|---|
|Catalogno.<br>Max fuse amprating<br>Stud<br>C5268-1<br>200<br>5/16-18 x 1"<br>~~=~~||
|C5268-2|200<br>5/16-18 x 1-3/4"|
|C5268-3|200<br>5/16-18 x 3/4"|
|C5268-4|100<br>1/4-20 x 1"|
|C5268-5|100<br>1/4-20 x 1-3/4"|
|Catalogno.<br>Max rated voltage<br>Max fuse amprating<br>~~ee~~|Catalogno.<br>Max rated voltage<br>Max fuse amprating<br>~~ee~~|
|---|---|
|BH-0|700<br>100|
|BH-1<br>BH-2|2500<br>400<br>5000<br>600|
|BH-3|1250<br>700<br>~~—~~|
1BS10x connector type
Bussmann series 1BS10 blocks utilize a tin-plated connector for wire termination and heat dissipation), and a plated-steel stud for fuse mounting. The connector type block is available in the configurations shown below. Consult your Bussmann series product representative for additional product details.
|Catalogno.<br>Max rated voltage<br>Max fuse amprating<br>~~ee~~|Catalogno.<br>Max rated voltage<br>Max fuse amprating<br>~~ee~~|
|---|---|
|1BS101|600<br>100|
|1BS102|600<br>400|
|1BS103|600<br>400|
|1BS104|600<br>600|
Data sheets: 1200 (BH-0), 1201 (BH-1), 1202 (BH-2), 1203 (BH-3), 1206 (1BS101), 1207 (1BS102), 1208 (1BS103), 1209 (1BS104)
Eaton.com/bussmannseries
4-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## LCT, LET BS88
240 Vac/150 Vdc (IEC), 250-280 Vac/150 Vdc (UL), 6 to 180 A
BS88 style bolted tag high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Low watts loss in a compact size.
Ratings
- Volts
- LCT 240 Vac/150 Vdc (IEC), 250 Vac/150 Vdc (UL)
- LET 280 Vac/150 Vdc (UL, 25-160 A), 250 Vac/150 Vdc (UL 180 A)
- Amps 6-180 A
- IR
- 200 kA RMS Sym.
- 50 kA DC at 125 Vdc
- 100 kA at 80 Vdc (70-1000 A)
Operating class aR.
Agency information
- Designed and tested to BS88 Part 4 and IEC 60269 Part 4
- UL Recognized*
- CCC (LCT only)
- CE
- All fuses have been tested at 318 Vac. Consult Bussmann series product representative for UL Recognized status.
Dimensions — mm
**==> picture [272 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
47<br>38<br>28 8.7<br>—<br>6.4 4<br>Ter e e<br>5.5<br>LCT<br>High speed fuses<br>**----- End of picture text -----**<br>
**==> picture [263 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
55<br>41<br>19.1<br>26<br>r e S i )<br>6.95 12.7 17.7<br>9.7<br>Ts ; 1 )<br>2.34<br>Indicator (optional)<br>LET — indicator optional<br>**----- End of picture text -----**<br>
|Fuse symbol<br>Rated voltage<br>Rated current(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 240 Vac<br>6<br>2.0<br>9<br>1.0<br>6LCT<br>~~SS~~<br>~~aa~~|Fuse symbol<br>Rated voltage<br>Rated current(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 240 Vac<br>6<br>2.0<br>9<br>1.0<br>6LCT<br>~~SS~~<br>~~aa~~|Fuse symbol<br>Rated voltage<br>Rated current(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 240 Vac<br>6<br>2.0<br>9<br>1.0<br>6LCT<br>~~SS~~<br>~~aa~~|Fuse symbol<br>Rated voltage<br>Rated current(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 240 Vac<br>6<br>2.0<br>9<br>1.0<br>6LCT<br>~~SS~~<br>~~aa~~|Fuse symbol<br>Rated voltage<br>Rated current(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 240 Vac<br>6<br>2.0<br>9<br>1.0<br>6LCT<br>~~SS~~<br>~~aa~~|
|---|---|---|---|---|
|LCT|240 Vac/150 Vdc (IEC)<br>250 Vac/150 Vdc (UL)|10<br>12<br>16|3.8<br>22<br>7.0<br>32<br>20.0<br>100|2.5<br>10LCT<br>2.5<br>12LCT<br>2.5<br>16LCT|
|||20|25.0<br>160|4.0<br>20LCT|
|||25|18.0<br>250|4.0<br>25LET|
|||32|32.0<br>450|5.0<br>32LET|
|||35|50.0<br>600|5.0<br>35LET|
|||50|100.0<br>1400|7.0<br>50LET|
|LET|280 Vac/150 Vdc (UL)|63<br>80|180.0<br>2200<br>300.0<br>3800|9.0<br>63LET<br>10.0<br>80LET|
|||100|600.0<br>7500|10.0<br>100LET|
|||125|600.0<br>7500|16.0<br>125LET|
|||160|1100.0<br>16,000|20.0<br>160LET|
||250 Vac/150 Vdc (UL)|180|1600.0<br>29,000|21.0<br>180LET|
- Watts loss at rated current.
Note: 7LET, 10LET, 12LET and 16LET are available for replacement purposes on existing equipment.
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 720004, 5785296 (LCT), 5785293 (LET)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-15
- **4 — High speed fuses**
- ~~I~~
## LMT, LMMT BS88
240 Vac/150 Vdc (IEC), 250 Vac/150 Vdc (UL), 160 to 900 A
BS88 style bolted tags high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Low watts loss in a compact size.
## Ratings
- Volts
- 240 Vac/150 Vdc (IEC)
- 250 Vac/150 Vdc (UL)
- Amps 160-900 A
- IR
- 200 kA RMS Sym., 40 kA at 150 Vdc (IEC)
- 200 kA RMS Sym., 50 kA at 150 Vdc (UL)
## Operating class aR
## Agency information
- Designed and tested to BS88 Part 4 and IEC 60269 Part 4
- UL Recognized*
- CCC
## • CE
- All fuses have been tested at 318 Vac. Consult Bussmann series product representative for UL Recognized status.
||||I²t (A²s)||
|---|---|---|---|---|
|Fuse symbol<br>Rated voltage|Rated current<br>(amps)|Pre-arcing|Clearingat<br>120 Vac<br>240 Vac|Watts loss<br>(W)†<br>Catalogno.|
||160|1100|7000<br>16,000|17<br>160LMT|
||200|1500|10,000<br>20,000|28<br>200LMT|
|LMT<br>240 Vac /150 Vdc (IEC)<br>250 Vac /150 Vdc (UL)|250<br>315<br>355|3200<br>6000<br>8000|20,000<br>40,000<br>35,000<br>75,000<br>50,000<br>100,000|28<br>250LMT<br>35<br>315LMT<br>35<br>355LMT|
||400|14,000|70,000<br>160,000|40<br>400LMT|
||450|18,000|100,000<br>220,000|42<br>450LMT|
||400|6000|35,000<br>80,000|60<br>400LMMT|
||500|14,000|80,000<br>170,000|64<br>500LMMT|
|LMMT<br>240 Vac /150 Vdc (IEC)<br>250 Vac /150 Vdc (UL)|630<br>710<br>800|24,000<br>32,000<br>52,000|150,000<br>300,000<br>200,000<br>460,000<br>300,000<br>600,000|75<br>630LMMT<br>77<br>710LMMT<br>82<br>800LMMT|
||900|75,000|400,000<br>800,000|97<br>900LMMT|
- Watts loss at rated current.
## Dimensions — mm
**==> picture [534 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
83.5 41.3 83.5 82.5<br>58.0 58.0<br>30.5 3.15 30.5 6.5<br>25.4 cm c, 83.5 F 38.1 25.4 10.3 : 38.1<br>fetter 13.5 Ce) etf 13.5 s CE D<br>LMT — indicator optional LMMT — indicator optional<br>**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 720004, 5785294 (LMT), 5785295 (LMMT)
Eaton.com/bussmannseries
4-16
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## CT, ET, FE, EET, FEE BS88
690 Vac/500 Vdc (IEC), 700 Vac/500 Vdc (UL), 6 to 200 A
BS88 style bolted tags high speed fuses for the protection of DC common bus, DC drives, power converters /rectifiers and reduced rated voltage starters.
## Ratings
- Volts
- 690 Vac/500 Vdc (IEC)
- 700 Vac/500 Vdc (UL)
- Amps 6-200 A
- IR
- CT: IEC — 90 kA RMS Sym., 40 kA at 500 Vdc, UL — 200 kA RMS Sym., 50 kA at 500 Vdc
- ET, EET, FE and FEE: 200 kA RMS Sym.,50 kA at 500 Vdc
Operating class aR
Agency information
- Designed and tested to BS88 part 4 and IEC 60269 Part 4
- UL Recognized*
- CCC for ET, FE, EET, FEE
- CE
- Consult your Bussmann series product representative for UL Recognized status.
Dimensions — mm
**==> picture [496 x 275] intentionally omitted <==**
**----- Start of picture text -----**<br>
9.7<br>74.6<br>64.3<br>55 7.1<br>48.0<br>6.4 4 63.5 17.7<br>ets<br>5.5<br>19.1<br>8.7<br>77.0<br>CT Jt 2.34 ‘ 12.7<br>ET, FE — indicator optional<br>94.0<br>71.0<br>19.5<br>46.0<br>.<br>31.8 8.7 36.0<br>11.9<br>1.6<br>Too SF é l<br>**----- End of picture text -----**<br>
EET, FEE — indicator optional
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 5785312 (CT, ET), 5785314 (FE), 5785313 (EET), 5785292 (FEE)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-17
**4 — High speed fuses**
## CT, ET, FE, EET, FEE BS88
690 Vac/500 Vdc (IEC), 700 Vac/500 Vdc (UL), 6 to 200 A
**==> picture [537 x 411] intentionally omitted <==**
**----- Start of picture text -----**<br>
I²t (A²s)<br>Rated current Watts<br>Fuse symbol Rated voltage (amps) Pre-arcing Clearing at 415 Vac Clearing at 660 Vac loss (W)† Catalog no.<br>6 1.8 8.5 12 2 6CT<br>10 7.0 30.0 48 3 10CT<br>690 Vac/500 Vdc (IEC)<br>CT 12 10.0 40.0 65 3 12CT<br>700 Vac/500 Vdc (UL) 16 16.0 66.0 110 7 16CT<br>20 32.0 150.0 220 7 20CT<br>25 25.0 150.0 250 7 25ET<br>32 32.0 190.0 350 11 32ET<br>35 52.0 310.0 500 11 35ET<br>690 Vac/500 Vdc (IEC) 40 103.0 600.0 900 9 40ET<br>ET<br>700 Vac/500 Vdc (UL) 45 103.0 680.0 1100 11 45ET<br>56 135.0 950.0 1500 14 56ET<br>63 171.0 1200.0 2000 16 63ET<br>80 360.0 2500.0 4000 18 80ET<br>35 33.0 130.0 200 9 35FE<br>40 52.0 180.0 300 9 40FE<br>45 76.0 270.0 450 11 45FE<br>50 103.0 380.0 600 11 50FE<br>690 Vac/500 Vdc (IEC)<br>FE 63 135.0 480.0 750 12 63FE<br>700 Vac/500 Vdc (UL) 71 210.0 600.0 950 17 71FE<br>80 250.0 900.0 1500 20 80FE<br>90 360.0 1300.0 2100 20 90FE<br>100 470.0 1800.0 2800 23 100FE<br>90 490.0 300.0 4500 19 90EET<br>690 Vac/500 Vdc (IEC) 110 600.0 4000.0 6500 27 110EET<br>EET<br>700 Vac/500 Vdc (UL) 140 1050.0 7000.0 12,000 35 140EET<br>160 1500.0 10,000.0 17,000 39 160EET<br>100 400.0 1600.0 2400 24 100FEE<br>120 540.0 1900.0 3100 32 120FEE<br>690 Vac/500 Vdc (IEC) 140 850.0 2500.0 3800 36 140FEE<br>FEE<br>700 Vac/500 Vdc (UL) 160 1000.0 3700.0 5700 46 160FEE<br>180 1400.0 5300.0 8400 46 180FEE<br>200 1900.0 7100.0 11,400 52 200FEE<br>**----- End of picture text -----**<br>
† Watts loss at rated current.
Note: FC, 8ET, 12ET, 15ET, 20ET, 65EET and 75EET are available for replacement purposes on existing equipment.
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 5785312 (CT, ET), 5785314 (FE), 5785313 (EET), 5785292 (FEE)
Eaton.com/bussmannseries
4-18
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## ETON
## FM, FMM, MT, MMT BS88
690 Vac/350-450 Vdc (IEC),700 Vac/500 Vdc (UL), 160 to 710 A
BS88 style bolted tags high speed fuses for the protection of DC common bus, DC drives, power converters /rectifiers and reduced rated voltage starters.
Ratings
- Volts
- FM: 690 Vac/450 Vdc (IEC); 700 Vac/500 Vdc (UL)
- FMM: 690 Vac/450 Vdc (IEC); 700 Vac (UL)
- MT and MMT: 690 Vac/350 Vdc (IEC); 700 Vac (UL)
- Amps 160-710 A
- IR
- FM: 200 kA RMS Sym. (IEC/UL), 40 kA at 450 Vdc (IEC), 50 kA at 500 Vdc (UL)
- FMM: 200 kA RMS Sym. (IEC/UL), 40 kA at 450 Vdc (IEC).
- MT and MMT: 200 kA RMS Sym. (IEC/UL), 40 kA at 350 Vdc (IEC).
Operating class aR
Agency information
- Designed and tested to BS88 Part 4 and IEC 60269 Part 4
- UL Recognized MT and MMT 350 Vdc (IEC) rating*
- CCC for FM and FMM
- CE
Consult your Bussmann series product representative for UL Recognized status.
## Dimensions — mm
**==> picture [260 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
112.0<br>84.0 41.3<br>49.5<br>3.15<br>25.4 10.3 38.1<br>‘Feq-frer 7<br>= 13.5 (D<br>FM, MT — indicator optional<br>**----- End of picture text -----**<br>
**==> picture [313 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
112.0<br>84.0 82.5<br>49.5 6.5<br>25.4 10.3 38.1<br>fei -<br>ter 13.5 Ci<br>FMM, MMT — indicator optional<br>**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 5785314 (FM), 5785313 (MT), 5785292 (FMM), 5785311 (MMT)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-19
**4 — High speed fuses**
## FM, FMM, MT, MMT BS88
690 Vac/350-450 Vdc (IEC), 700 Vac/500 Vdc (UL), 160 to 710 A
**==> picture [538 x 418] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated I²t (A²s)<br>current Watts loss<br>Fuse symbol Rated voltage (amps) Pre-arcing Clearing at 415 Vac Clearing at 660 Vac (W)† Catalog no.<br>180 1400 7500 13,500 40 180FM<br>200 2600 10,500 18,500 40 200FM<br>225 3700 14,500 26,500 44 225FM<br>690 Vac/450 Vdc (IEC)<br>FM 250 5200 20,500 37,500 48 250FM<br>700 Vac/500 Vdc (UL)<br>280 7000 30,500 55,000 48 280FM<br>315 10,000 40,000 77,000 55 315FM<br>350 15,000 60,000 105,000 55 350FM<br>400 10,000 40,000 72,500 85 400FMM<br>450 15,000 60,000 105,000 90 450FMM<br>690 Vac/450 Vdc (IEC) 500 20,000 82,000 150,000 100 500FMM<br>FMM<br>700 Vac (UL) 550 30,000 120,000 215,000 100 550FMM<br>630 45,000 180,000 310,000 100 630FMM<br>700 60,000 245,000 420,000 120 700FMM<br>160 2400 15,000 25,000 26 160MT<br>180 3800 25,000 38,000 26 180MT<br>200 6000 40,000 58,000 27 200MT<br>690 Vac/350 Vdc (IEC)<br>MT 250 11,500 80,000 110,000 32 250MT<br>700 Vac (UL)<br>280 16,500 100,000 150,000 35 280MT<br>315 19,000 125,000 180,000 42 315MT<br>355 22,000 160,000 200,000 51 355MT<br>180 1650 12,000 18,000 42 180MMT<br>200 2200 16,000 23,000 42 200MMT<br>225 3700 26,000 40,000 42 225MMT<br>280 6600 47,000 70,000 47 280MMT<br>315 8600 62,000 91,000 51 315MMT<br>690 Vac/350 Vdc (IEC) 355 13,500 97,000 140,000 54 355MMT<br>MMT<br>700 Vac (UL) 400 21,000 150,000 220,000 60 400MMT<br>450 30,000 220,000 320,000 57 450MMT<br>500 42,000 300,000 450,000 64 500MMT<br>560 60,000 430,000 640,000 64 560MMT<br>630 68,500 500,000 720,000 86 630MMT<br>710 78,000 600,000 850,000 105 710MMT<br>**----- End of picture text -----**<br>
† Watts loss at rated current.
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 5785314 (FM), 5785313 (MT), 5785292 (FMM), 5785311 (MMT)
Eaton.com/bussmannseries
4-20
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## BS 88 Accessories
## Trip indicator
Trip-indicator fuses are available for use in parallel with the main BS88-4 fuses. They can either be attached to the associated fuse or mounted separately in panel mounted fuse clips. Push-on adapters with microswitch (catalog numbers MAI and MBI) are available for use with the trip indicator to provide a means for remote indication.
Fuse ratings of 20 A and below cannot usually accommodate a trip fuse in parallel.
When a trip-indicator is to be attached to the main fuse, an accessory pack comprising a pair of mounting clips and an appropriate trip indicator is required. The clips are snapped onto the fuse and the indicator is pressed into clips as shown below.
Trip indicator kit catalog numbers (indicator + clips)
|Trip indicator kit catalog numbers (indicator + clips)|Trip indicator kit catalog numbers (indicator + clips)|Trip indicator kit catalog numbers (indicator + clips)|
|---|---|---|
|For fuse symbol<br>Catalogno.<br>ET<br>EC-600<br>~~—Yy_~~|||
||EET<br>EC-600||
||FE<br>EC-600||
|FEE<br>EC-600<br>LET<br>EC-250<br>FM<br>MC-600<br>FMM<br>MC-600<br>LMT<br>MC-250<br>LMMT<br>MC-250<br>~~re~~|||
|Indicator only<br>Catalogno.<br>Rated current<br>Dim. ‘A’ (mm)|||
||TI250<br>250<br>37.6||
||TI500<br>500<br>47.5||
||TI600<br>600<br>55.7||
||TI700<br>700<br>61.8||
||TI1100<br>1100<br>98.4||
|TI1500<br>1500<br>120.8<br>TI2000<br>2000<br>147.5<br>TI2500<br>2500<br>198.3<br>~~——~~|||
## Microswitches
## Microswitch/adapter: MAI and MBI
To provide a means of remote indication with the trip indicators, we offer two microswitch/adapters. The microswitches are provided with double pole, single throw contacts, having both a normally open (NO) and a normally closed (NC) position. A special material is used in the construction of the adapter to provide reliable operation in the temperatures ranges associated with standard operating conditions and during fuse operation.
|Catalog no.<br>Description<br>Terminal orientation<br>~~ss~~|||
|---|---|---|
|MAI<br>Trip indicator adapter and<br>microswitch<br>Back|||
|MBI<br>Trip indicator adapter and<br>microswitch<br>Side<br>~~TT~~|||
|Microswitch ratings (MAI and MBI)|||
|Terminals<br>Quick connect|||
|Current rating|||
|AC 50/60 Hz resistive load<br>4 A @ 250 V RMS<br>6 A @ 127 V RMS<br>DC, resistive load<br>0.7 A @ 110 Vdc<br>2 A @ 30 Vdc||High speed fuses|
|Maximum working voltage|||
|1000 V|||
|Contact-to-contact (RMS)|||
|1500 V|||
|Maximum DC volts<br>110 Vdc|||
## Indicator dimensions — mm
6 21 6.35 0.8 A ~~Jo~~ 6.0
## Indicator panel mount clips
CL1 panel mount fuse clips are available for mounting a trip-indicator directly to a PCB or insulated panel, or when mounting directly on the fuse is impractical. Order catalog number CL1. CL1 dimensions — mm
**==> picture [125 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
6.0<br>14 8.7<br>50.8<br>[ |<br>B<br>**----- End of picture text -----**<br>
Microswitch/adapter dimensions — mm
**==> picture [259 x 121] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.8 2.4 5.2 3.6<br>5.2<br>“at ame i“ t s<br>44 36 44 36 3.6<br>i ' T<br>9.5<br>21 21<br>NC NC<br>NO NO<br>MAI or MBI<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-21
**4 — High speed fuses** ~~i~~
## FWA Ferrule
150 Vac/dc (UL), 10x38mm and 21x51mm, 5 to 60 A
Ferrule style high speed fuses for the protection of DC common bus, DC drives, power converters /rectifiers and reduced rated voltage starters.
## Ratings
- Volts 150 Vac/dc (UL)
- Amps 5-60 A
- IR
- 200 kA RMS Sym.
- 50 kA DC at 150 Vdc
Operating class aR
Agency information
- UL Recognized, JFHR2, E91958
- • CE
|Fuse size<br>Rated voltage<br>Rated current<br>(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 150 Vac<br>5<br>1.6<br>8<br>2.0<br>FWA-5A10F<br>~~ee~~|Fuse size<br>Rated voltage<br>Rated current<br>(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 150 Vac<br>5<br>1.6<br>8<br>2.0<br>FWA-5A10F<br>~~ee~~|Fuse size<br>Rated voltage<br>Rated current<br>(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 150 Vac<br>5<br>1.6<br>8<br>2.0<br>FWA-5A10F<br>~~ee~~|Fuse size<br>Rated voltage<br>Rated current<br>(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 150 Vac<br>5<br>1.6<br>8<br>2.0<br>FWA-5A10F<br>~~ee~~|Fuse size<br>Rated voltage<br>Rated current<br>(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 150 Vac<br>5<br>1.6<br>8<br>2.0<br>FWA-5A10F<br>~~ee~~|
|---|---|---|---|---|
|||10|3.6<br>16|2.7<br>FWA-10A10F|
|10x38mm (13/32”x1-1/2”)||15<br>20|14.0<br>50<br>33.0<br>130|3.3<br>FWA-15A10F<br>3.8<br>FWA-20A10F|
|||25|58.0<br>220|4.9<br>FWA-25A10F|
||150 Vac/dc (UL)|30|100.0<br>400|4.9<br>FWA-30A10F|
|||35|75.0<br>800|4.5<br>FWA-35A21F|
|||40|100.0<br>1000|5.1<br>FWA-40A21F|
|21x51mm (13/16”x2”)||45|130.0<br>1300|6.0<br>FWA-45A21F|
|||50|170.0<br>1600|7.3<br>FWA-50A21F|
|||60|250.0<br>2400|8.0<br>FWA-60A21F|
- Watts loss at rated current.
Dimensions — in (mm) A C aT s B a ~~H~~ Amp range A B C 5-30 1.5 (38.1) 0.38 (9.5) 0.41 (10.3) 35-60 2.0 (50.8) 0.63 (15.9) 0.81 (20.6)
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 720003,5785317 (5-30 A), 5785305 (35-60 A)
Eaton.com/bussmannseries
4-22
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4** ~~a~~
## FWX Ferrule
250 Vac/dc (UL), 14x51mm, 1 to 50 A
Ferrule style high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers rated voltage starters.
Ratings
- Volts
- 250 Vac (UL, all ratings)
- 250 Vdc (UL, 5-50 A only)
- Amps 1-50 A
- IR
- 200 kA RMS Sym. (UL, all ratings)
- 50 kA at 250 Vdc (UL, 5-50 A only)
Operating class aR
Agency information
- UL Recognized, JFHR2, E91958 1-50 A
- CSA Class 1422-30, 1422-90 (53787) 5-30 A
> • CE
|Fuse size<br>Rated voltage<br>Rated current(amps)<br>I²t (A²s)<br>Watts loss<br>(W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 250 Vac<br>1<br>0.03<br>0.40<br>5.7<br>FWX-1A14F<br>~~a~~|Fuse size<br>Rated voltage<br>Rated current(amps)<br>I²t (A²s)<br>Watts loss<br>(W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 250 Vac<br>1<br>0.03<br>0.40<br>5.7<br>FWX-1A14F<br>~~a~~|Fuse size<br>Rated voltage<br>Rated current(amps)<br>I²t (A²s)<br>Watts loss<br>(W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 250 Vac<br>1<br>0.03<br>0.40<br>5.7<br>FWX-1A14F<br>~~a~~|Fuse size<br>Rated voltage<br>Rated current(amps)<br>I²t (A²s)<br>Watts loss<br>(W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 250 Vac<br>1<br>0.03<br>0.40<br>5.7<br>FWX-1A14F<br>~~a~~|Fuse size<br>Rated voltage<br>Rated current(amps)<br>I²t (A²s)<br>Watts loss<br>(W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 250 Vac<br>1<br>0.03<br>0.40<br>5.7<br>FWX-1A14F<br>~~a~~|Fuse size<br>Rated voltage<br>Rated current(amps)<br>I²t (A²s)<br>Watts loss<br>(W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 250 Vac<br>1<br>0.03<br>0.40<br>5.7<br>FWX-1A14F<br>~~a~~|
|---|---|---|---|---|---|
||250 Vac (UL)|2<br>3|0.08<br>0.10<br>0.11<br>0.26|8.6<br>FWX-2A14F<br>2.8<br>FWX-3A14F||
|||4|0.1<br>0.23|3.0<br>FWX-4A14F||
|||5|1.6<br>13.00|1.3<br>FWX-5A14F||
|14x51mm (9/16”x2”)||10|3.6<br>24.00|3.4<br>FWX-10A14F||
|||15|14.0<br>83.00|3.8<br>FWX-15A14F||
||250 Vac/dc (UL)|20|33.0<br>200.00|4.6<br>FWX-20A14F||
|||25|58.0<br>300.00|5.3<br>FWX-25A14F||
|||30|100.0<br>500.00|5.9<br>FWX-30A14F||
|||50|200.0<br>1800.00|5.7<br>FWX-50A14F||
- Watts loss at rated current.
Dimensions — mm (in)
**==> picture [236 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
50.8 14.3<br>(2.0) (0.56)<br>T D C<br>15.5<br>t (0.61) o<br>**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 720006, 5785302
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-23
**4 — High speed fuses**
## FWH Ferrule
500 Vac (UL), 6x32mm, 0.25 to 30 A
**==> picture [32 x 27] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>@><br>**----- End of picture text -----**<br>
Ferrule style high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters.
## Ratings
- Volts
- 500 Vac (UL — 0.25-1 A and 3.15-30 A)
- 1000 Vac (UL — 2 A)
- 600 Vdc (UL — 1-5 A)
- Amps 0.25-30 A
- IR
- 50 kA AC (0.25-1 A and 3.15-20 A)
- 30 kA AC (2 A)
- 20 kA AC (25-30 A)[1]
- 50 kA DC (1-5 A))
- 1 Tested at PF = 76%.
**==> picture [194 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — mm (in)<br>6.4<br>(0.25)<br>31.8<br>(1.25)<br>3.2<br>(0.125)<br>**----- End of picture text -----**<br>
Operating class aR
Agency information
- UL Recognized, JFHR2, E91958 (0.25-7 A) and JDYX2, E19180 (10-30 A)
- CSA Component Acceptance Class 1422-30, 1422-90 (53787) 0.25-7 A
|Opening times|||
|---|---|---|
|Amp range<br>150%|200%|300%<br>Min IR|
|0.25-7||300 %|
|>30 min<br>10-30|>30 min|≤ 10 sec<br>200 %|
- RoHS compliant
- CE
||Rated voltage||I2t (A2s)|||Catalogno.|
|---|---|---|---|---|---|---|
|Amps|Vac<br>Vdc|Pre-arcing|Clearing@ 500Vac|Watts loss (W)†|Standard|RoHS compliant|
|0.25|—|0.01|0.05|2.7||FWH-.250A6F|
|0.5|500|0.05|0.25|1.2||FWH-.500A6F|
|1||0.4|2|1.7||FWH-001A6F|
|2|1000|1.3|3.5|3.2||FWH-002A6F|
|3.15|600|3.1|7.7|2.9|—|FWH-3.15A6F|
|4||—|—|—||FWH-004A6F|
|5||15|40|2.1||FWH-005A6F|
|6.3||36|90|2.3||FWH-6.30A6F|
|7||50|125|2.5||FWH-007A6F|
|10||9.9|139|2.86|FWH5-010A6F|FWH5-010A6FR|
||500||||||
|12.5||20|60|3.53|FWH5-12-5A6F|FWH5-12-5A6FR|
|15|—|44|146|3.08|FWH5-015A6F|FWH5-015A6FR|
|16||48|177|4.48|FWH5-016A6F|FWH5-016A6FR|
|20||75|259|4.26|FWH5-020A6F|FWH5-020A6FR|
|25||126|345|—|FWH-025A6F|FWH-025A6FR|
|30||145|430|—|FWH-030A6F|FWH-030A6FR|
† Watts loss at rated current.
Data sheet no.720038
Eaton.com/bussmannseries
4-24
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## FWH Ferrule
500 Vac/ Vdc (UL), 14x51mm, 1 to 30 A
Ferrule style high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters.
Ratings
- Volts
- 500 Vac (UL, all ratings)
- 500 Vdc (UL, 5-30 A only)
- Amps 1-30 A
- IR
- 200 kA RMS Sym. all ratings
- 50 kA at 500 Vdc 5-30 A only
Operating class aR
Agency information
- UL Recognized 1-30 A
- CSA Class 1422-30, (53787) 5-30 A
- CE
||||I²t (A²s)||
|---|---|---|---|---|
|Fuse size|Rated voltage|Rated current (amps)|Pre-arcing<br>Clearingat 500 Vac|Watts loss (W)†<br>Catalogno.|
|||1|0.04<br>0.2|5.7<br>FWH-1A14F|
||500 Vac (UL)|2<br>3|0.08<br>0.1<br>0.11<br>0.2|8.7<br>FWH-2A14F<br>2.8<br>FWH-3A14F|
|||4|0.10<br>0.2|3.0<br>FWH-4A14F|
|||5|2.00<br>7.0|1.5<br>FWH-5A14F|
|14x51mm (9/16"x2")||6<br>10|2.00<br>7.0<br>4.00<br>15.0|1.5<br>FWH-6A14F<br>4.0<br>FWH-10A14F|
||500 Vac/dc (UL)|12<br>15|7.00<br>25.0<br>10.00<br>40.0|4.3<br>FWH-12A14F<br>5.5<br>FWH-15A14F|
|||20|26.00<br>100.0|6.5<br>FWH-20A14F|
|||25|49.00<br>200.0|7.0<br>FWH-25A14F|
|||30|58.00<br>240.0|9.0<br>FWH-30A14F|
- Watts loss at rated current.
Dimensions — mm (in)
**==> picture [256 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
50.8 14.3<br>(2.0) (0.56)<br>as h e<br>15.5<br>t (0.61) k<br>**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets:720008, 5785298
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-25
**4 — High speed fuses**
## FWC Ferrule
## 600-700 Vac/700 Vdc (UL), 10x38mm, 1 to 32 A
Ferrule style high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters.
## Ratings
- Volts
- 700 Vac/dc (UL, 1-4 A)
- 600 Vac (UL, 6-32 A), 700 Vdc (UL, 6-25 A)
- Amps 1-32 A
- IR
- 200 kA RMS Sym. at 600 Vac (6-32 A)
- 200 kA RMS Sym. at 700 Vac (1-4 A)
- 10 kA DC at 700 Vdc (1-25 A)
## Operating class aR
## Agency information
- UL Recognized, JFHR8, E91958 6-32 A
- CSA Class 1422-30, (53787) 6-32 A
- CE
|Fuse size|Rated voltage|Rated current<br>(amps)|I²t (A²s)<br>Pre-arcing<br>Clearingat 600 Vac|Watts loss (W)†<br>Catalogno.|
|---|---|---|---|---|
|||1|0.2<br>1.2|0.5<br>FWC-1A10F|
||700 Vac/dc (UL)|2<br>3|0.5<br>3.0<br>1.6<br>11.0|1.2<br>FWC-2A10F<br>1.5<br>FWC-3A10F|
|||4|5.2<br>32.0|1.5<br>FWC-4A10F|
|||6|4.0<br>30.0|1.5<br>FWC-6A10F|
|10x38mm (13/32"x1-1/2")||8<br>10|6.0<br>50.0<br>9.0<br>70.0|2.0<br>FWC-8A10F<br>2.5<br>FWC-10A10F|
||600 Vac/700 Vdc (UL)|12|15.0<br>120.0|3.0<br>FWC-12A10F|
|||16|25.0<br>150.0|3.5<br>FWC-16A10F|
|||20|34.0<br>260.0|4.8<br>FWC-20A10F|
|||25|60.0<br>390.0|6.0<br>FWC-25A10F|
||600 Vac (UL)|32|95.0<br>600.0|7.5<br>FWC-32A10F|
- Watts loss at rated current.
## Dimensions — mm
**==> picture [168 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
38<br>10<br>9.5<br>**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets:720011, 5785306
Eaton.com/bussmannseries
4-26
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## FWP Ferrule
690 Vac (IEC) 10x38mm, 4 to 32 A
Ferrule style Class gR high speed fuses for the protection of AC/DC drives and semiconductors.
Ratings
- Volts 690 Vac
- Amps 4-32 A
- IR
- 200 kA RMS Sym.
Operating class gR
Agency information
- UL 248-13
- Designed and tested to IEC 60269, Part 4
- CE
|||I²t(A²s)<br>Watts loss(W)†||
|---|---|---|---|
|Fuse type<br>Fuse size<br>Rated voltage|Rated current<br>(amps)<br>4|Pre-arcing<br>Clearingat 690 Vac<br>0.8I~~n~~<br>I~~n~~<br>5.6<br>17<br>1.13<br>2.05|Catalogno.<br>FWP-4G10F|
||6|16.0<br>48<br>1.56<br>3.0|FWP-6G10F|
||8|4.3<br>38<br>0.97<br>1.68|FWP-8G10F|
||10|6.6<br>59<br>1.20<br>2.09|FWP-10G10F|
|Without striker<br>10x38 mm<br>690 Vac (IEC)|12|9.6<br>84<br>1.69<br>2.99|FWP-12G10F|
||16|17.0<br>150<br>2.31<br>4.27|FWP-16G10F|
||20|23.5<br>200<br>2.86<br>5.35|FWP-20G10F|
||25|60.2<br>512<br>2.94<br>5.52|FWP-25G10F|
||32**|94.0<br>800<br>3.82<br>7.43|FWP-32G10F|
- Watts loss at rated current.
- ** 32 A rated current with 25mm[2] conductors, derate to 27 A with 6mm[2] conductors.
Data sheet no. 10467
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-27
**4 — High speed fuses** TNE
## FWP Ferrule
690 Vac (IEC), 700 Vac (UL), 600 - 700 Vdc (UL), 14x51mm, 1 to 50 A
Ferrule style Class aR high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Available with or without striker.
## Ratings
- Volts 690 Vac (IEC), 700 Vac/600 Vdc (UL) with striker (see table for striker version)
- Amps 1-50 A
- IR
- 200 kA RMS Sym.
- 50 kA at 800 Vdc (5-50 A non striker version)
- 600 Vdc for striker version
## Operating class aR
## Agency information
- UL Recognized, (without striker only) JFHR2, E91958
- CSA (without striker only) Class 1422-30, 1422-90 (53787)
- Designed and tested to IEC 60269, Part 4
- CE
**==> picture [523 x 369] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Rated|I²t (A²s)|
|current|
|Fuse type|Fuse size|Rated voltage|(amps)|Pre-arcing|Clearing at 700 Vac|Watts loss (W)†|Catalog no.|
|1|0.04|0.41|5.7|FWP-1A14F|
|2|0.08|0.11|8.7|FWP-2A14F|
|700 Vac (UL)|
|3|0.11|0.26|2.8|FWP-3A14F|
|4|0.10|0.23|3.0|FWP-4A14F|
|5|2.00|11.00|1.5|FWP-5A14F|
|10|4.00|22.00|4.0|FWP-10A14F|
|Without striker|15|10.00|70.00|5.5|FWP-15A14F|
|20|26.00|180.00|6.5|FWP-20A14F|
|690 Vac (IEC)|25|49.00|320.00|7.0|FWP-25A14F|
|700 Vac/dc (UL)|
|30|58.00|400.00|9.0|FWP-30A14F|
|14x51mm (9/16”x2”)|32|68.00|600.00|8.0|FWP-32A14F|
|40|84.00|750.00|8.0|FWP-40A14F|
|50|200.00|1800.00|9.0|FWP-50A14F|
|10|4.00|32.00|2.0|FWP-10A14FI|
|15|7.00|63.00|4.0|FWP-15A14FI|
|20|26.00|234.00|4.0|FWP-20A14FI|
|25|42.00|378.00|4.0|FWP-25A14FI|
|With striker|700 Vac/600 Vdc (UL)|
|30|52.00|468.00|6.0|FWP-30A14FI|
|32|68.00|600.00|8.0|FWP-32A14FI|
|40|84.00|750.00|8.0|FWP-40A14FI|
|50|200.00|1800.00|9.0|FWP-50A14FI|
|† Watts loss at rated current.|
|Dimensions — mm (in)|
|50.8|14.3|59 (2.32)|
|(2.0)|(0.56)|51 (2.0)|
|14.3|
|(0.56)|13.0 (0.5)|
|15.5|
|Without striker|(0.61)|With striker|(0.2)5.0|
**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 720025, 5781724 fuses without striker; 5785566 fuses with striker
Eaton.com/bussmannseries
4-28
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## STON men
## FWP Ferrule
690 Vac 14x51mm, 1 to 50 A
Ferrule style Class gR high speed fuses for the protection of AC/DC drives, semiconductors and high voltage auxiliary circuits in electric vehicles. Available with or without striker.
Ratings
- Volts 690 Vac
- Amps 4-50 A
- IR 200 kA RMS Sym.
Operating class gR
Agency information
- UL 248-13
- Designed and tested to IEC 60269, Part 4
- CE
|Fuse type<br>Fuse size<br>Rated voltage<br>Rated<br>current<br>(amps)<br>I²t(A²s)<br>Watts loss(W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 690 Vac<br>0.8I~~n~~<br>I~~n~~<br>4<br>5.6<br>17<br>1.56<br>2.94<br>FWP-4G14F<br>~~ee~~|Fuse type<br>Fuse size<br>Rated voltage<br>Rated<br>current<br>(amps)<br>I²t(A²s)<br>Watts loss(W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 690 Vac<br>0.8I~~n~~<br>I~~n~~<br>4<br>5.6<br>17<br>1.56<br>2.94<br>FWP-4G14F<br>~~ee~~|Fuse type<br>Fuse size<br>Rated voltage<br>Rated<br>current<br>(amps)<br>I²t(A²s)<br>Watts loss(W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 690 Vac<br>0.8I~~n~~<br>I~~n~~<br>4<br>5.6<br>17<br>1.56<br>2.94<br>FWP-4G14F<br>~~ee~~|Fuse type<br>Fuse size<br>Rated voltage<br>Rated<br>current<br>(amps)<br>I²t(A²s)<br>Watts loss(W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 690 Vac<br>0.8I~~n~~<br>I~~n~~<br>4<br>5.6<br>17<br>1.56<br>2.94<br>FWP-4G14F<br>~~ee~~|Fuse type<br>Fuse size<br>Rated voltage<br>Rated<br>current<br>(amps)<br>I²t(A²s)<br>Watts loss(W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 690 Vac<br>0.8I~~n~~<br>I~~n~~<br>4<br>5.6<br>17<br>1.56<br>2.94<br>FWP-4G14F<br>~~ee~~|
|---|---|---|---|---|
|||6|16<br>48<br>2.25<br>4.2|FWP-6G14F|
|||8|3.8<br>30<br>1.18<br>2.0|FWP-8G14F|
|||10|5.9<br>47<br>1.41<br>2.52|FWP-10G14F|
|||12|8.4<br>68<br>1.95<br>3.54|FWP-12G14F|
|Without striker||16|15<br>120<br>5.67<br>4.83|FWP-16G14F|
|||20|27<br>170<br>2.91<br>5.4|FWP-20G14F|
|||25|53<br>333<br>3.38<br>6.0|FWP-25G14F|
|||32|108<br>679<br>3.72<br>6.93|FWP-32G14F|
||14x51mm (9/16”x2”)<br>690 Vac (UL/IEC)|40<br>50|211<br>1331<br>4.13<br>7.52<br>350<br>2200<br>5.36<br>9.8|FWP-40G14F<br>FWP-50G14F|
|||8|3.8<br>30<br>1.18<br>2.0|FWP-8G14FI|
|||10|5.9<br>47<br>1.41<br>2.52|FWP-10G14FI|
|||12|8.4<br>68<br>1.95<br>3.54|FWP-12G14FI|
|||16|15<br>120<br>5.67<br>4.83|FWP-16G14FI|
|With striker||20|27<br>170<br>2.91<br>5.4|FWP-20G14FI|
|||25|53<br>333<br>3.38<br>6.0|FWP-25G14FI|
|||32|108<br>679<br>3.72<br>6.93|FWP-32G14FI|
|||40|211<br>1331<br>4.13<br>7.52|FWP-40G14FI|
|||50|350<br>2200<br>5.36<br>9.8|FWP-50G14FI|
† Watts loss at rated current.
Dimensions — mm (in)
50.8 14.3 59 (2.32) (2.0) (0.56) 51 (2.0) 14.3 (0.56) 13.0 (0.5) ~~i~~ tp ), ~~=~~ 15.5 Without striker O ~~05~~ (0.61) ~~6~~ With striker en (0.2)5.0 ~~tcn~~
Data sheet no. 10468
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-29
**4 — High speed fuses**
## FWP Ferrule
700 Vac/dc (UL), 22x58mm, 20 to 100 A
Ferrule style high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Available with or without striker.
## Ratings
- Volts 700 Vac/dc (UL)
- Amps 20-100 A
- IR
- 200 kA RMS Sym.
- 50 kA at 700 Vdc, L/R 5 ms
## Operating class aR
Agency information
- UL Recognized, (without striker only) JFHR2, E91958
- CSA (without striker only) Class 1422-30, 1422-90 (53787)
- CE
|||Rated current|I²t(A²s)||
|---|---|---|---|---|
|Fuse type|Fuse size<br>Rated voltage|(amps)|Pre-arcing<br>Clearingat 700 Vac|Watts loss(W)†<br>Catalogno.|
|||20|23.0<br>330|5.0<br>FWP-20A22F|
|||25|37.0<br>530|6.0<br>FWP-25A22F|
|||32|55.0<br>780|8.0<br>FWP-32A22F|
|Without striker||40<br>50|68.0<br>960<br>155.0<br>2200|12.0<br>FWP-40A22F<br>12.5<br>FWP-50A22F|
|||63|280.0<br>4000|15.0<br>FWP-63A22F|
|||80|550.0<br>7800|15.0<br>FWP-80A22F|
||22x58mm (7/8"x2-9/32")<br>700 Vac/dc (UL|100<br>20|1100.0<br>15,600<br>19.0<br>260|16.5<br>FWP-100A22F<br>5.0<br>FWP-20A22FI|
|||25|34.0<br>410|6.0<br>FWP-25A22FI|
|||32|53.5<br>605|8.0<br>FWP-32A22FI|
|With striker||40<br>50|68.0<br>750<br>135.0<br>1600|9.0<br>FWP-40A22FI<br>9.5<br>FWP-50A22FI|
|||63|280.0<br>3080|11.0<br>FWP-63A22FI|
|||80|600.0<br>6600|13.5<br>FWP-80A22FI|
|||100|1100.0<br>12,500|16.0<br>FWP-100A22FI|
- Watts loss at rated current.
Dimensions — mm (in)
**==> picture [214 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
58.0 22.2<br>(2.28) (0.87)<br>G P<br>| | |<br>15.0<br>Without striker a (0.6) ke O<br>**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets:720026, 5781723
Eaton.com/bussmannseries
4-30
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## FWP Ferrule
690 Vac, 500 Vdc 22x58mm, 20 to 100 A
Ferrule style Class gR high speed fuses for the protection of AC/DC drives, semiconductors and high voltage auxiliary circuits in electric vehicles. Available with or without striker.
## Ratings
- Volts
- 690 Vac
- 500 Vdc
- Amps 20-100 A
- IR
- 200 kA RMS Sym.
- 50 kA DC
## Operating class gR
## Agency information
- UL 248-13
- Designed and tested to IEC 60269, Part 4
- CE
|||Rated current|I²t(A²s)<br>Watts loss(W)†||
|---|---|---|---|---|
|Fuse type|Fuse size<br>Rated voltage|(amps)<br>20|Pre-arcing<br>Clearingat 690 Vac<br>0.8I~~n~~<br>I~~n~~<br>24<br>154<br>3.23<br>6.00|Catalogno.<br>FWP-20G22F|
|||25|43<br>274<br>3.66<br>6.65|FWP-25G22F|
|||32|97<br>616<br>4.86<br>9.21|FWP-32G22F|
|Without striker||40<br>50|180<br>899<br>4.50<br>8.24<br>273<br>1362<br>6.26<br>11.85|FWP-40G22F<br>FWP-50G22F|
|||63|516<br>2575<br>7.35<br>13.80|FWP-63G22F|
|||80|1092<br>5448<br>8.40<br>14.00|FWP-80G22F|
||22x58 mm<br>(7/8"x2-9/32") 690 Vac, 500Vdc|100<br>20|2065<br>10,300<br>9.40<br>17.70<br>24<br>154<br>3.23<br>6.00|FWP-100G22F<br>FWP-20G22FI|
|||25|43<br>274<br>3.66<br>6.65|FWP-25G22FI|
|||32|97<br>616<br>4.86<br>9.21|FWP-32G22FI|
|With striker||40<br>50|180<br>899<br>4.50<br>8.24<br>273<br>1362<br>6.26<br>11.85|FWP-40G22FI<br>FWP-50G22FI|
|||63|516<br>2575<br>7.35<br>13.80|FWP-63G22FI|
|||80|1092<br>5448<br>8.40<br>14.00|FWP-80G22FI|
|||100|2065<br>10,300<br>9.40<br>17.70|FWP-100G22FI|
† Watts loss at rated current.
Dimensions — mm (in)
**==> picture [395 x 70] intentionally omitted <==**
**----- Start of picture text -----**<br>
58.0 22.2<br>(2.28) (0.87)<br>|<br>— 15.0 GY cept<br>Without striker (0.6)<br>**----- End of picture text -----**<br>
Data sheet no. 10469
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-31
**4 — High speed fuses** ~~i~~
## FWK Ferrule
750 Vdc (IEC), 20x127mm and 25x146mm, 5 to 60 A
Ferrule style high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters.
Ratings
- Volts 750 Vdc (IEC)
- Amps
- 5-30 A (20x127mm)
- 35-60 A (25x146mm)
- IR 50 kA at 750 Vdc, L/R 10-15 ms
Operating class gG
Agency information
- CE
|Fuse size<br>Rated voltage<br>Rated current<br>(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 750 Vac<br>5<br>8.5<br>16<br>6.7<br>FWK-5A20F<br>~~PS~~|Fuse size<br>Rated voltage<br>Rated current<br>(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 750 Vac<br>5<br>8.5<br>16<br>6.7<br>FWK-5A20F<br>~~PS~~|Fuse size<br>Rated voltage<br>Rated current<br>(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 750 Vac<br>5<br>8.5<br>16<br>6.7<br>FWK-5A20F<br>~~PS~~|Fuse size<br>Rated voltage<br>Rated current<br>(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 750 Vac<br>5<br>8.5<br>16<br>6.7<br>FWK-5A20F<br>~~PS~~|Fuse size<br>Rated voltage<br>Rated current<br>(amps)<br>I²t (A²s)<br>Watts loss (W)†<br>Catalogno.<br>Pre-arcing<br>Clearingat 750 Vac<br>5<br>8.5<br>16<br>6.7<br>FWK-5A20F<br>~~PS~~|
|---|---|---|---|---|
|||8|50<br>100|8.8<br>FWK-8A20F|
|||10|95<br>200|8.5<br>FWK-10A20F|
|20x127mm (13/32"x5")||15|100<br>240|5.0<br>FWK-15A20F|
|||20|125<br>315|7.8<br>FWK-20A20F|
||750 Vdc (IEC)|25|400<br>1100|6.5<br>FWK-25A20F|
|||30|800<br>2600|6.5<br>FWK-30A20F|
|||35|1300<br>4600|6.0<br>FWK-35A25F|
|25x146mm (1”x5-3/4")||40<br>50|1600<br>5300<br>3100<br>12,000|6.8<br>FWK-40A25F<br>7.3<br>FWK-50A25F|
|||60|5900<br>24,000|7.7<br>FWK-60A25F|
- Watts loss at rated current.
Dimensions — mm (in)
**==> picture [450 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
127.0 20.5 146.0 24.5<br>r (5.0) e (0.81) ee (5.75) n (1.0)<br>16.0<br>T 5-30 A — 20x127mm DO (0.63) 35-60 A — 25x146mm F r 20.64<br>(0.8)<br>**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets:720039, 5785031
Eaton.com/bussmannseries
4-32
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## FWJ Ferrule
1000 Vac/800 Vdc (UL), 14x67mm, 20 to 30 A
Ferrule style high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers, reduced rated voltage starters and high voltage auxiliary circuits in electric vehicles.. Available with or without striker for remote indication.
## Ratings
- Volts 1000 Vac/800 Vdc
- Amps 20-30 A
- IR
- 25 kA RMS Sym.
- 50 kA at 800 Vdc
## Operating class aR
## Agency information
- UL Recognized, JFHR2, E91958
- CE
|Fuse size<br>Rated voltage|Rated current<br>(amps)|I²t (A²s)<br>Pre-arcing<br>Clearingat 1000 Vac|Watts loss (W)†<br>Catalogno.|
|---|---|---|---|
||20|25<br>220|9<br>FWJ-20A14F|
|14x67mm (9/16"x2-5/8")<br>1000 Vac/ 800 Vdc (UL)|25|33<br>350|11<br>FWJ-25A14F|
||30|52<br>450|14<br>FWJ-30A14F|
- Watts loss at rated current.
## Dimensions — mm
**==> picture [284 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
67<br>14<br>10<br>**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets:720028, 5785315
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-33
**4 — High speed fuses**
## FWL Ferrule
1200 Vac/1000 Vdc (IEC), 20x127mm, 20 to 30 A
Ferrule style high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Available with indicator.
## Ratings
- Volts
- 1200 Vac (IEC)
- 1000 Vdc (IEC)
- Amps 20-30 A
- IR
- 50 kA RMS Sym.
- 50 kA at 1000 Vdc
## Operating class gR
## Agency information
- IEC 60077
- CE
|Fuse type|Fuse size<br>Rated voltage|Rated current<br>(amps)|I²t(A²s)<br>Pre-arcing<br>Clearingat 1000 Vac|Watts<br>loss<br>(W)†<br>Catalogno.|
|---|---|---|---|---|
|||20|675<br>1550|5.9<br>FWL-20A20F|
|Without indicator||25|1200<br>2760|6.5<br>FWL-25A20F|
||20x127mm (13/16"x5")<br>1200 Vac/1000 Vdc (IEC)|30<br>20|1850<br>4300<br>675<br>1550|7.5<br>FWL-30A20F<br>5.9<br>FWL-20A20FI|
|With indicator||25|1200<br>2760|6.5<br>FWL-25A20FI|
|||30|1850<br>4300|7.5<br>FWL-30A20FI|
- Watts loss at rated current.
Dimensions — mm
For details on electrical characteristics, contact Application Engineering and ask for data sheets:720040, 5785455
Eaton.com/bussmannseries
4-34
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## FWS Ferrule
1400 - 2000 Vac/1000 Vdc (IEC), 20x127mm, 2 to 15 A
Ferrule style high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Available with indicator.
## Ratings
- Volts
- 2000 Vac/1000 Vdc (IEC, 2-8 A)
- 1400 Vac/1000 Vdc (IEC, 10-15 A)
- Amps 2-15 A
- IR
- 50 kA RMS Sym.
- 50 kA at 1000 Vdc (2-10 A only)
## Operating class gG
## Agency information
- IEC 60077
- CE
|Fuse type|Fuse size|Rated voltage|Rated current<br>(amps)|I²t(A²s)<br>Pre-arcing<br>Clearingat 1000 Vac|Watts loss(W)†<br>Catalogno.|
|---|---|---|---|---|---|
||||2|0.8<br>2.4|4.4<br>FWS-2A20F|
|||2000 Vac/1000 Vdc (IEC)|6|27.0<br>81.0|6.7<br>FWS-6A20F|
|Without indicator|||8<br>10|64.0<br>192.0<br>118.0<br>277.0|7.6<br>FWS-8A20F<br>3.0<br>FWS-10A20F|
|||1400 Vac/1000 Vdc (IEC)|12|170.0<br>380.0|3.4<br>FWS-12A20F|
||20x127mm||15|209.0<br>500.0|5.0<br>FWS-15A20F|
||(13/16"x5")||2|0.8<br>2.4|4.4<br>FWS-2A20FI|
|||2000 Vac/1000 Vdc (IEC)|6|27.0<br>81.0|6.7<br>FWS-6A20FI|
|With indicator|||8<br>10|64.0<br>192.0<br>118.0<br>277.0|7.6<br>FWS-8A20FI<br>3.0<br>FWS-10A20FI|
|||1400 Vac/1000 Vdc (IEC)|12|170.0<br>380.0|3.4<br>FWS-12A20FI|
||||15|209.0<br>500.0|5.0<br>FWS-15A20FI|
† Watts loss at rated current.
## Dimensions — mm
For details on electrical characteristics, contact Application Engineering and ask for data sheets:720040, 5785109
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-35
## **4 — High speed fuses**
## Ferrule fuse accessories
JM70100 DIN-Rail/panel mount block for 22x58mm fuses
Modular, open-style fuse blocks for 22x58mm cylindrical fuses feature versatile 35mm DIN-Rail or screw-to-panel mounting. Available optional IP20 finger-safe covers with lockout/tagout capability come in indicating and non-indicating versions. For use with FWP fuses.
## Ratings
- Volts 700 Vac
- Amps 100 A
- Withstand rating 200 kA
Agency information
## • UL Recognized, Guide IZTL2, File 14853
|Catalogno.<br>Poles|Terminal<br>type|Optional IP20 cover catalogno.*<br>Indicating**<br>Non-indicating|
|---|---|---|
|JM70100-1CR<br>1|||
|JM70100-2CR<br>2|Box lug|CVRI-J-60060<br>CVR-J-60060|
|JM70100-3CR<br>3|||
* Order separately, one cover per pole.
- ** Indication requires 90 V minimum and energized, closed circuit.
Data sheet no. 10496
CHM modular DIN-Rail mount holders for 10x38mm fuses
Bussmann series compact IP20 finger-safe modular DIN-Rail mount fuse holders for 10x38mm cylindrical fuses.
|Catalogno.<br>With<br>indicator<br>Without<br>indicator|Rated voltage<br>and current|Agency<br>information|Number ofpoles|Terminal rating|Rated withstand<br>capacity|Compatible<br>Bussmann<br>series fuses|
|---|---|---|---|---|---|---|
|CHM1DIU<br>CHM1DU|||1||||
|CHM2DIU<br>CHM2DU<br>CHM3DIU<br>CHM3DU<br>CHM4DIU<br>CHM4DU<br>CHM1DNIU<br>CHM1DNU<br>~~oe~~|IEC 690 Vac/32 A<br>UL 600 Vac/30 A|IEC 60269-2<br>UR; CSA; CCC<br>IEC 60269-2|PVC/copper cable, solid,<br>stranded, fine stranded,<br>fork lug, comb busbar;<br>single and dual<br>2<br>3<br>4<br>1-pole + 1 neutral<br>~~IEC:~~<br>1 to25mm?70°C||IEC 120 kA RMS Sym.<br>UL 200 kA RMS Sym.<br>CCC 100 kA RMS Sym.|FWA, FWC.|
|CHM3DNIU<br>CHM3DNU|||3-pole + 1 neutral||||
|—<br>CHM1DNXU|IEC 690 Vac/32 A|IEC 60269-2|1 neutral||N/A|N/A|
Data sheet no. 10430
Eaton.com/bussmannseries
4-36
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## Ferrule fuse accessories
CH14 and CH22 modular DIN-Rail holders
Bussmann series compact DIN-Rail mount fuse holders for 14x51mm and 22x58mm cylindrical fuses. Available in different versions with neutral and microswitch.
Mounting
- 35mm DIN-Rail
- Panel mount (2xM4 screws)
|Panel mount (2xM4 screws)|Panel mount (2xM4 screws)||||pw||“sna|
|---|---|---|---|---|---|---|---|
|Panel mount (2xM4 screws)|Panel mount (2xM4 screws)|||CH14|pw|CH22|“sna|
|Without<br>indicator|Catalog no.<br>With indicator|Description|Rated voltage<br>and current|Agency<br>markings|Terminal rating|Rated<br>withstand<br>capacity|Compatible<br>Bussmann<br>series fuses|
|14x51mm||||||||
|CH141DNXU|—|Neutral only||||||
|CH141DU|CH141DIU|1 pole||||||
|CH142DU|CH142DIU|2 pole||||||
|CH143DU<br>CH143DIU<br>CH144DU<br>CH144DIU<br>CH141DNU<br>CH141DNIU<br>CH143DNU<br>CH143DNIU<br>CH141DMSU-F<br>—<br>CH143DMSU-F<br>—||3 pole<br>4 pole<br>1 pole + neutral<br>3 pole + neutral<br>1 pole with microswitch<br>3 pole with microswitch|690 Vac/50 A<br>750 Vdc/50 A|IEC 60269-1<br>IEC 60269-2|Size: 2.5-50mm2<br>Torque: 3 N•m max|120 kA AC|FWX-A14F1,<br>FWH-A14F1,<br>FWP-A14F1, 2|
|CH143DNMSU-F<br>—||3 pole +neutral with<br>microswitch||||||
|22x58mm||||||||
|CH221DNXU|—|Neutral holder||||||
|CH221DU|CH221DIU|1 pole fuse holder||||||
|CH222DU|CH222DIU|2 pole fuse holder||||||
|CH223DU|CH223DIU|3 pole fuse holder||||||
|CH224DU|CH224DIU|4 pole fuse holder|690 Vac/125 A|IEC 60269-1|Size: 4 - 50 mm2|120 kA AC||
|CH221DNU|CH221DNIU|1 pole + neutral|1000 Vdc/125 A|IEC 60269-2|Torque: 4 N•m max|50 kA DC|FWP ferrule1, 2|
|CH223DNU|CH223DNIU|3 pole + neutral||||||
|—|CH221DMSU-F|1 pole with microswitch||||||
|—|CH223DMSU-F|3 pole with microswitch||||||
|—|CH223DNMSU-F|3 pole with microswitch<br>+ neutral||||||
1 Maximum allowed continuous current applies. Please refer to data sheet for details.
2 Please consult our application engineers if you wish to use a FWP fuse with a striker option.
## CH14 and CH22 accessories
|Catalogno.|Description|For holder|
|---|---|---|
|AL-D|Multi-polegangingclips, one kit willgangupto 4-poles together|CH14 and CH22|
|CH14-P|Multi-pole handlepins, one kit willgangupto 12 handles together|CH14 and CH22|
|CH14-L|Lockoutpadlock support, it will accept upto 5mm diameterpadlock shank|CH14|
|CH22-L|Lockoutpadlock support, it will accept upto 5mm diameterpadlock shank|CH22|
|CH14-IP20<br>CH22-IP20|IP20 protection accessory, provides IP20 protection to terminals with 10mm2or less cable|CH14<br>CH22|
|CH14-MS1<br>CH22-MS1|1-pole microswitch for blown fuse monitoring|CH14<br>CH22|
|CH14-MS3<br>CH22-MS3|3-pole microswitch for blown fuse monitoring|CH14<br>CH22|
Data sheet no. 10080 (CH14), 10115 (CH22)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-37
## **4 — High speed fuses**
## 170M — Square Body size 000 and 00, DIN 43653
690 Vac (IEC), 700 Vac/dc (UL), 10 to 400 A
Square body DIN 43653 bolted tags high speed fuses, for the protection of DC common bus, DC drives, power converters/ rectifiers and reduced rated voltage starters. Available with and without visual indicator, and Type T indicator for a microswitch.
## Ratings
- Volts
- 690 Vac (IEC, size 000 and 00)
- 700 Vac (UL, size 000; size 00 100-400 A only)
- 700 Vdc (UL, size 000)
- Amps 10-400 A
- IR
- 200 kA RMS Sym.
- 50 kA at 700 Vdc (size 000 only)
## Operating class
- gR - size 000 (10-63 A), size 00 (25-80 A)
- aR - size 000 (>63 A), size 00 (>80 A)
## Agency Information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085
- CSA Class 53787, File 1422-30 on size 000
- CCC
- CE
## Dimensions — mm
The dotted line represents the Type T indicator fuse.
**==> picture [246 x 222] intentionally omitted <==**
**----- Start of picture text -----**<br>
54<br>u vA Indicator* ro 74<br>G<br>D<br>K<br>t <— E —|<br>100<br>k———__—— 78<br>¥<br>H ++ F<br>F 1<br>Type -U/80, -/80, -TN/80<br>Size D E F G H K<br>000 40 21 20 51 8 2<br>00 51 30 28 67 10 2<br>**----- End of picture text -----**<br>
* Indicatior for size 00 fuses is a red pin.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6310 (Size 000), 170K6312 (Size 00)
Eaton.com/bussmannseries
4-38
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 000 and 00, DIN 43653
690 Vac (IEC), 700 Vac/dc (UL), 10 to 400 A
**==> picture [562 x 394] intentionally omitted <==**
**----- Start of picture text -----**<br>
I²t (A²s) Catalog no.<br>Rated Clearing Watts -TN/80 Type<br>current at 660 loss -U/80 -/80 T indicator for<br>Fuse size Rated voltage (amps) Pre-Arcing Vac (W)† without indicator with indicator microswitch<br>10 3.8 25.5 3.0 170M1308 170M1358 170M1408<br>16 7.2 48.0 5.5 170M1309 170M1359 170M1409<br>20 11.5 78.0 7.0 170M1310 170M1360 170M1410<br>25 19.0 130.0 9.0 170M1311 170M1361 170M1411<br>32 40.0 270.0 10.0 170M1312 170M1362 170M1412<br>40 69.0 460.0 12.0 170M1313 170M1363 170M1413<br>50 115.0 770.0 15.0 170M1314 170M1364 170M1414<br>690 Vac (IEC)<br>000 63 215.0 1450.0 16.0 170M1315 170M1365 170M1415<br>700 Vac/dc (UL) 80 380.0 2550.0 19.0 170M1316 170M1366 170M1416<br>100 695.0 4650.0 24.0 170M1317 170M1367 170M1417<br>125 1250.0 8500.0 28.0 170M1318 170M1368 170M1418<br>160 2350.0 16,000.0 32.0 170M1319 170M1369 170M1419<br>200 4200.0 28,000.0 37.0 170M1320 170M1370 170M1420<br>250 7750.0 51,500.0 42.0 170M1321 170M1371 170M1421<br>315 12,000.0 80,500.0 53.0 170M1322 170M1372 170M1422<br>25 19.0 130.0 6.0 170M2608 170M2658<br>32 28.5 195.0 7.0 170M2609 170M2659<br>40 50.0 360.0 9.0 170M2610 170M2660<br>00 690 Vac (IEC)<br>50 95.0 640.0 10.0 170M2611 170M2661<br>63 170.0 1200.0 12.0 170M2612 170M2662<br>80 310.0 2100.0 15.0 170M2613 170M2663<br>100 620.0 4150.0 20.0 170M2614 170M2664<br>125 1000.0 6950.0 25.0 — 170M2615 170M2665<br>160 1900.0 13,000.0 30.0 170M2616 170M2666<br>690 Vac (IEC) 200 3400.0 23,000.0 35.0 170M2617 170M2667<br>00<br>700 Vac (UL) 250 6250.0 42,000.0 45.0 170M2618 170M2668<br>315 10,000.0 68,500.0 55.0 170M2619 170M2669<br>350 13,500.0 91,500.0 60.0 170M2620 170M2670<br>400 18,000.0 125,000.0 70.0 170M2621 170M2671<br>High speed fuses<br>**----- End of picture text -----**<br>
† Watts loss at rated current.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6310 (Size 000), 170K6312 (Size 00)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-39
## **4 — High speed fuses**
## 170M — Square Body size 1* to 3, DIN 43653
## 690 Vac (IEC), 700 Vac (UL), 40 to 2000 A
Square body DIN 43653 bolted tags high speed fuses, for the protection of DC common bus, DC drives, power converters/ rectifiers and reduced rated voltage starters. Available with visual indicator, and Type K and T indicator for a microswitch.
Ratings
- Volts
- 690 Vac (IEC)/700 Vac (UL)
- 750 Vdc (UL, see catalog number table for specific fuses)
- Amps 40-2000 A
- IR 200 kA RMS Sym.
## Operating class aR
## Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2*, E125085
- CSA Class 53787, File 1422-30*
- CCC except where noted
## • CE
- Consult your Bussmann series product representative for status.
## Dimensions — mm
1mm = 0.0394”
Type -/80, -TN/80, -/110, -TN/110
Type -KN/80, -KN/110
|Size|A|B|B1|C|C1|D2|E|H||Size|A|B|B3|C|C3|D|E|H|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|1*|50|104|134|78|108|58|45|22||1*|50|104|134|78|108|59|45|22|
|1|50|108|138|78|108|66|53|25||1|50|108|138|78|108|69|53|25|
|2|50|108|138|78|108|75|61|25||2|50|108|138|78|108|77|61|25|
|3|51|109|139|78|108|90|76|30||3|51|109|139|78|108|92|76|30|
- 1 Valid for fuse Types -/110 and -TN/110.
- 3 Valid for fuse Type -KN/110.
- 2 Valid for fuse Types -TN/80 and -TN/110.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6314 (Size 1*), 170K6316 (Size 1), 170K6318 (Size 2), 170K6320 (Size 3)
Eaton.com/bussmannseries
4-40
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 1* to 3, DIN 43653
690 Vac (IEC), 700 Vac (UL), 40 to 2000 A
**==> picture [561 x 593] intentionally omitted <==**
**----- Start of picture text -----**<br>
I²t (A²s) Catalog no.<br>Rated Watts -TN/80 Type T -KN/80 Type -TN/110 Type -KN/110 Type<br>Fuse Rated current Clearing at loss -/80 with indicator for K indicator -/110 with T indicator K indicator<br>size voltage (amps) Pre-arcing 660 Vac (W)† indicator micro for micro indicator for micro for micro<br>40 40 270 9 170M3008 170M3058 170M3108 170M3158 170M3208 170M3258<br>50 77 515 11 170M3009 170M3059 170M3109 170M3159 170M3209 170M3259<br>63 115 770 14 170M3010 170M3060 170M3110 170M3160 170M3210 170M3260<br>80 185 1250 18 170M3011 170M3061 170M3111 170M3161 170M3211 170M3261<br>100 360 2450 21 170M3012 170M3062 170M3112 170M3162 170M3212 170M3262<br>125 550 3700 26 170M3013 170M3063 170M3113 170M3163 170M3213 170M3263<br>160 1100 7500 30 170M3014 170M3064 170M3114 170M3164 170M3214 170M3264<br>690 Vac (IEC) 200 2200 15,000 35 170M3015 170M3065 170M3115 170M3165 170M3215 170M3265<br>1*<br>700 Vac (UL) 250 4200 28,500 40 170M3016 170M3066 170M3116 170M3166 170M3216 170M3266<br>315 7000 46,500 50 170M3017 170M3067 170M3117 170M3167 170M3217 170M3267<br>350 10,000 68,500 55 170M3018 170M3068 170M3118 170M3168 170M3218 170M3268<br>400 15,000 105,000 60 170M3019 170M3069 170M3119 170M3169 170M3219 170M3269<br>450 21,000 140,000 65 170M3020 170M3070 170M3120 170M3170 170M3220 170M3270<br>500 27,000 180,000 70 170M3021 170M3071 170M3121 170M3171 170M3221 170M3271<br>550 34,000 230,000 75 170M3022 170M3072 170M3122 170M3172 170M3222 170M3272<br>630 48,500 325,000 80 170M3023 170M3073 170M3123 170M3173 170M3223 170M3273<br>200 1650 11,500 45 170M4008 170M4058 170M4108 170M4158 170M4208 170M4258<br>250 3100 21,000 55 170M4009 170M4059 170M4109 170M4159 170M4209 170M4259<br>315 6200 42,000 58 170M4010 170M4060 170M4110 170M4160 170M4210 170M4260<br>350 8500 59,000 60 170M4011 170M4061 170M4111 170M4161 170M4211 170M4261<br>400 13,500 91,500 65 170M4012 170M4062 170M4112 170M4162 170M4212 170M4262<br>1 690 Vac (IEC) 450 17,000 120,000 70 170M4013 170M4063 170M4113 170M4163 170M4213 170M4263<br>700 Vac (UL) 500 25,000 170,000 72 170M4014 170M4064 170M4114 170M4164 170M4214 170M4264<br>550 34,000 230,000 75 170M4015 170M4065 170M4115 170M4165 170M4215 170M4265<br>630 52,000 350,000 80 170M4016 170M4066 170M4116 170M4166 170M4216 170M4266<br>700 69,500 465,000 85 170M4017 170M4067 170M4117 170M4167 170M4217 170M4267<br>800 105,000 725,000 95 170M4018 170M4068 170M4118 170M4168 170M4218 170M4268<br>900 [2] 155,000 850,000 [2] 100 170M4019 [1] 170M4069 [1] 170M4119 [1] 170M4169 [1] 170M4219 [1] 170M4269 [1]<br>400 11,000 74,000 65 170M5008 170M5058 170M5108 170M5158 170M5208 170M5258<br>450 15,500 105,000 70 170M5009 170M5059 170M5109 170M5159 170M5209 170M5259<br>500 21,500 145,000 75 170M5010 170M5060 170M5110 170M5160 170M5210 170M5260<br>550 28,000 190,000 80 170M5011 170M5061 170M5111 170M5161 170M5211 170M5261<br>690 Vac (IEC) 630 41,000 275,000 90 170M5012 170M5062 170M5112 170M5162 170M5212 170M5262<br>2 700 60,500 405,000 95 170M5013 170M5063 170M5113 170M5163 170M5213 170M5263<br>700 Vac (UL) 800 86,000 575,000 105 170M5014 170M5064 170M5114 170M5164 170M5214 170M5264<br>900 125,000 840,000 110 170M5015 170M5065 170M5115 170M5165 170M5215 170M5265<br>1000 180,000 1,250,000 115 170M5016 170M5066 170M5116 170M5166 170M5216 170M5266<br>1100 [3] 245,000 1,600,000 120 170M5017 170M5067 170M5117 170M5167 170M5217 170M5267<br>1250 [3] 365,000 2,400,000 130 170M5018 170M5068 170M5118 170M5168 170M5218 170M5268<br>500 14,000 95,000 95 170M6008 170M6058 170M6108 170M6158 170M6208 170M6258<br>550 19,500 135,000 100 170M6009 170M6059 170M6109 170M6159 170M6209 170M6259<br>630 31,000 210,000 105 170M6010 170M6060 170M6110 170M6160 170M6210 170M6260<br>700 44,500 300,000 110 170M6011 170M6061 170M6111 170M6161 170M6211 170M6261<br>800 69,500 465,000 115 170M6012 170M6062 170M6112 170M6162 170M6212 170M6262<br>900 100,000 670,000 120 170M6013 170M6063 170M6113 170M6163 170M6213 170M6263<br>3 690 Vac (IEC) 1000 140,000 945,000 125 170M6014 170M6064 170M6114 170M6164 170M6214 170M6264<br>700 Vac (UL) 1100 190,000 1,300,000 130 170M6015 170M6065 170M6115 170M6165 170M6215 170M6265<br>1250 290,000 1,950,000 140 170M6016 170M6066 170M6116 170M6166 170M6216 170M6266<br>1400 370,000 2,450,000 155 170M6017 170M6067 170M6117 170M6167 170M6217 170M6267<br>1500 460,000 3,100,000 160 170M6018 170M6068 170M6118 170M6168 170M6218 170M6268<br>1600 580,000 3,900,000 160 170M6019 170M6069 170M6119 170M6169 170M6219 170M6269<br>1800 [4] 880,000 5,250,000 [4] 165 170M6020†† 170M6070†† 170M6120 170M6170†† 170M6220†† 170M6270<br>2000 [5] 1,150,000 6,350,000 [5] 175 170M6021 170M6071 170M6121 170M6171 170M6221 170M6271<br>High speed fuses<br>**----- End of picture text -----**<br>
- Watts loss at rated current.
- †† DC voltage rated at 750 Vdc, IR 130 kA DC, UL Recognized, File E12085.
- 1 Not UL Recognized, 2 Rated voltage: 550 Vac IEC, 3 Rated voltage: 600 Vac IEC, 700 Vac UL, 4 Rated voltage: 600 Vac IEC, 500 Vac UL, 5 Rated voltage: 550 Vac IEC, 500 Vac UL.
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 170K6314 (Size 1*), 170K6316 (Size 1), 170K6318 (Size 2), 170K6320 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-41
**4 — High speed fuses**
## 170M — Square Body size 00, DIN 43653
1000 Vac (IEC and UL), 20 to 315 A
Square body DIN 43653 bolted tags high speed fuses, for the protection of DC common bus, DC drives, power converters/ rectifiers and reduced rated voltage starters. Available with indicator or Type T indicator for a microswitch.
## Ratings
- Volts
- 1000 Vac (IEC and UL 20-250 A)
- 900 Vac (IEC, 315 A)
- Amps 20-315 A
- IR 125 kA RMS Sym.
Operating class aR
Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, E125085, JFHR2 (20-250 A)
- CSA Class 53787, File 1422-30 (20-250 A)
- CE
|Fuse size|Rated voltage|Rated<br>current<br>(amps)|I²t (A²s)<br>Pre-arcing<br>Clearing at<br>rated voltage|Watts<br>loss<br>(W)†|Catalogno.<br>00/80 with indicator<br>00TN/80 Type T indicator for<br>micro|
|---|---|---|---|---|---|
|||20|20<br>140|5|170M4802<br>170M4822|
|||25|30<br>210|7|170M4803<br>170M4823|
|||32|55<br>390|9|170M4804<br>170M4824|
|||35|69<br>500|10|170M4805<br>170M4825|
|||40|100<br>690|11|170M4806<br>170M4826|
|||50|170<br>1200|13|170M4807<br>170M4827|
|00|1000 Vac (IEC/UL)|63<br>80|280<br>2000<br>500<br>3500|18<br>22|170M4808<br>170M4828<br>170M4809<br>170M4829|
|||100|950<br>6850|25|170M4810<br>170M4830|
|||125|1500<br>11,500|33|170M4811<br>170M4831|
|||160|3000<br>22,000|37|170M4812<br>170M4832|
|||200|5600<br>40,500|40|170M4813<br>170M4833|
|||250|10,000<br>74,000|48|170M4814<br>170M4834|
||900 Vac (IEC)|315|18,000<br>115,000|58|170M4815<br>170M4835|
- Watts loss at rated current.
Dimensions — mm
**==> picture [249 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
28.0 2.0<br>_ [a] [i] Indicator<br>10.0 27.0 Tag for microswitch<br>= {| roa a<br>© ©<br>78.0 54.0<br>98.0<br>elle<br>= a Ty<br>27.0<br>45.0<br>L 47.7 30.0<br>I 10.0 65.5<br>**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for Data sheet no. 170K8504
Eaton.com/bussmannseries
4-42
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 1* to 3, DIN 43653
1000 Vac (IEC and UL), 50 to 1400 A
Square body DIN 43653 bolted tags high speed fuses, for the protection of DC common bus, DC drives, power converters/ rectifiers and reduced rated voltage starters. Available with a Type T or K indicator for a microswitch.
## Ratings
- Volts
- 1000 Vac (IEC, 50-1250 A), 900 Vac (IEC, 1400 A)
- 1000 Vac (UL size 2, size 3, 315-1100 A only)
- 900 Vdc (UL, see catalog number table for specific fuses)
- Amps 50-1400 A
- IR 125 kA RMS Sym.
Operating class aR
## Agency Information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085 (only sizes 2 and 3)
- CCC (only size 3, 315-1100 A)
- CE
Dimensions — mm
**==> picture [536 x 218] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|C|E|C|
|A|
|A|
|SOCe|%~|Indicator|E|
|D1|Ae|p|>|OD|
|D1|
|G|
|H|
|4)|(LP»|G|©)ar)||
|H|
|E|
|J|
|B|Type -KN/110|E|
|J|Q)SS|
|Type -TN/110|
|B|
|Type -KN/110|Type -TN/110|
|es|Size|A|B|C|D1 (max)|E|G|H|J||=|Size|A|B|C|D1 (max)|E|G|H|J|
|1*KN/110|80|138|108|61|43|6|22|11|1*TN/110|80|138|108|61|43|6|22|11|
|1KN/110|80|138|108|69|51|6|25|11|1TN/110|80|138|108|69|51|6|25|11|
|2KN/110|80|138|108|77|59|6|25|11|2TN/110|80|138|108|75|59|6|25|11|
|3KN/110|81|139|108|92|74|6|30|11|3TN/110|81|139|108|90|74|6|30|11|
**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K8564 (Size 1*), 170K8566 (Size 1), 170K8568 (Size 2), 170K8570 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-43
**4 — High speed fuses**
## 170M — Square Body size 1* to 3, DIN 43653
1000 Vac (IEC and UL), 50 to 1400 A
**==> picture [537 x 574] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated I²t (A²s) Watts Catalog no.<br>current Clearing at loss -KN/110 Type K indicator for -TN/110 Type T indicator for<br>Fuse size Rated voltage (amps) Pre-arcing rated voltage (W)† microswitch microswitch<br>50 135 815 20 170M3965 170M3981<br>63 215 1300 25 170M3966 170M3982<br>80 460 2750 30 170M3967 170M3983<br>100 860 5100 35 170M3968 170M3984<br>125 1450 8600 40 170M3969 170M3985<br>1* 1000 Vac (IEC) 160 2850 17,500 45 170M3970 170M3986<br>200 4950 29,500 50 170M3971 170M3987<br>250 9550 57,000 55 170M3972 170M3988<br>315 21,500 130,000 65 170M3973 170M3989<br>350 29,000 175,000 70 170M3974 170M3990<br>400 42,000 250,000 75 170M3975 170M3991<br>160 2200 13,500 40 170M4965 170M4980<br>200 4150 24,500 45 170M4966 170M4981<br>250 7750 46,000 52 170M4967 170M4982<br>315 16,500 98,500 60 170M4968 170M4983<br>350 21,500 130,000 65 170M4969 170M4984<br>1 1000 Vac (IEC)<br>400 31,000 185,000 70 170M4970 170M4985<br>450 44,500 265,000 80 170M4971 170M4986<br>500 63,000 375,000 85 170M4972 170M4987<br>550 84,500 500,000 90 170M4973 170M4988<br>630 125,000 755,000 98 170M4974 170M4989<br>250 6750 40,000 65 170M5966 170M5981<br>315 13,500 81,500 75 170M5967 170M5982<br>350 16,500 99,000 80 170M5968 170M5983<br>400 26,000 155,000 85 170M5969 170M5984<br>450 35,500 210,000 90 170M5970 170M5985<br>2 1000 Vac (IEC and UL)<br>500 49,500 295,000 95 170M5971 170M5986<br>550 66,000 390,000 100 170M5972 170M5987<br>630 93,500 555,000 110 170M5973 170M5988<br>700 130,000 770,000 115 170M5974 170M5989<br>800 195,000 1,200,000 125 170M5975 170M5990<br>315 9200 54,500 90 170M8614 170M8629††<br>350 13,000 77,500 95 170M8615 170M8630††<br>400 19,000 115,000 105 170M8616 170M8631††<br>450 27,000 160,000 107 170M8617 170M8632††<br>500 37,500 225,000 110 170M8618 170M8633††<br>550 52,000 310,000 115 170M8619 170M8634††<br>1000 Vac (IEC and UL)<br>630 82,500 490,000 120 170M8620 170M8635††<br>3<br>700 115,000 700,000 125 170M8621 170M8636††<br>800 170,000 1,050,000 135 170M8622 170M8637††<br>900 250,000 1,500,000 145 170M8623 170M8638††<br>1000 340,000 2,050,000 150 170M8624 170M8639††<br>1100 460,000 2,750,000 155 170M8625 170M8640††<br>1000 Vac (IEC) 1250 575,000 3,400,000 175 170M8626 170M8641<br>900 Vac (IEC) 1400 795,000 4,200,000 185 170M8627 170M8642<br>**----- End of picture text -----**<br>
- Watts loss at rated current.
- †† DC voltage rated at 900 Vdc, UL Recognized, File E125085.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K8564 (Size 1*), 170K8566 (Size 1), 170K8568 (Size 2), 170K8570 (Size 3)
Eaton.com/bussmannseries
4-44
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 1* to 3, DIN 43653
1250 Vac (IEC), 1300 Vac (UL), 50 to 1400 A
Square body DIN 43653 bolted tags high speed fuses, for the protection of DC common bus, DC drives, power converters/ rectifiers and reduced rated voltage starters.
## Ratings
- Volts
- 1100 to 1300 Vac (see catalog number table)
- 900 and 1000 Vdc (UL, see catalog number table for specific fuses)
- Amps 50-1400 A
- IR 100 kA RMS Sym.
Operating class aR
Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2*, E125085
- CSA Class 53787, File 1422-30*
## • CE
- Consult your Bussmann series product representative for status.
## Dimensions — mm
1mm = 0.0394”
Type-/110-TN/110
## Type-KN/110
|Size<br>A<br>B<br>C<br>D1<br>E<br>H<br>K||Size<br>A<br>B<br>C<br>D<br>E<br>H<br>K|
|---|---|---|
|1*<br>80<br>138<br>108<br>58<br>45<br>20<br>11||1*<br>80<br>138<br>108<br>60<br>45<br>20<br>11|
|1<br>80<br>138<br>108<br>66<br>53<br>25<br>11||1<br>80<br>138<br>108<br>69<br>53<br>25<br>11|
|2<br>80<br>138<br>108<br>75<br>61<br>25<br>11||2<br>80<br>138<br>108<br>77<br>61<br>25<br>11|
|3<br>81<br>139<br>108<br>90<br>76<br>30<br>11||3<br>81<br>139<br>108<br>92<br>76<br>30<br>11|
- 1 Clip on microswitch valid for -TN/110 fuses.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6630 (Size 1*), 170K6632 (Size 1), 170K6634 (Size 2), 170K6636 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-45
**4 — High speed fuses**
## 170M — Square Body size 1* to 3, DIN 43653, 170M
1250 Vac (IEC), 1300 Vac (UL), 50 to 1400 A
**==> picture [537 x 618] intentionally omitted <==**
**----- Start of picture text -----**<br>
I²t (A²s) Catalog no.<br>Rated Watts -TN/110 Type -KN/110 Type<br>Fuse current Clearing at Clearing at loss -/110 with T indicator for K indicator for<br>size Rated voltage (amps) Pre-arcing 1000 Vac 1250 Vac (W) [†] indicator microswitch microswitch<br>50 135 815 1100 15 170M3138 170M3188 170M3238<br>63 215 1300 1750 20 170M3139 170M3189 170M3239<br>80 420 2500 3350 25 170M3140 170M3190 170M3240<br>100 750 4450 5950 30 170M3141 170M3191 170M3241<br>125 1450 9000 11,500 35 170M3142 170M3192 170M3242<br>1* 1250 Vac (IEC) 160 2600 16,000 21,000 40 170M3143 170M3193 170M3243<br>1300 Vac (UL)<br>200 5150 31,000 41,000 45 170M3144 170M3194 170M3244<br>250 9200 54,500 73,000 55 170M3145 170M3195 170M3245<br>315 18,500 115,000 150,000 60 170M3146 170M3196 170M3246<br>350 27,000 165,000 220,000 65 170M3147 170M3197 170M3247<br>400 53,000 265,000 335,000 70 170M3148 170M3198 170M3248<br>160 1900 11,500 15,500 45 170M4138†† 170M4188†† 170M4238††<br>200 3800 22,500 30,000 50 170M4139†† 170M4189†† 170M4239††<br>250 7750 46,000 61,500 60 170M4140†† 170M4190†† 170M4240††<br>315 15,000 90,000 120,000 65 170M4141†† 170M4191†† 170M4241††<br>1250 Vac (IEC) 350 20,000 125,000 165,000 70 170M4142†† 170M4192†† 170M4242††<br>1 1300 Vac (UL)<br>400 29,500 175,000 235,000 75 170M4143†† 170M4193†† 170M4243††<br>450 42,000 250,000 335,000 80 170M4144†† 170M4194†† 170M4244††<br>500 69,500 340,000 435,000 85 170M4145 170M4195 170M4245<br>550 95,000 465,000 590,000 95 170M4146 170M4196 170M4246<br>1100 Vac (IEC) 630 130,000 660,000 N/A 100 170M4147 [1] 170M4197 [1] 170M4247 [1]<br>250 6500 38,500 51,500 65 170M5138 170M5188 170M5238<br>280 9350 55,500 74,500 70 170M5139 170M5189 170M5239<br>315 13,000 77,500 105,000 75 170M5140 170M5190 170M5240<br>350 16,500 97,500 135,000 80 170M5141 170M5191 170M5241<br>400 23,000 140,000 180,000 85 170M5142 170M5192 170M5242<br>1250 Vac (IEC) 450 34,000 205,000 270,000 90 170M5143 170M5193 170M5243<br>1300 Vac (UL)<br>2 500 48,000 285,000 380,000 95 170M5144 170M5194 170M5244<br>550 62,000 370,000 495,000 100 170M5145 170M5195 170M5245<br>630 115,000 575,000 730,000 120 170M5146†† 170M5196†† 170M5246<br>700 160,000 795,000 1,050,000 125 170M5147†† 170M5197†† 170M5247<br>800 245,000 1,200,000 1,550,000 130 170M5148†† 170M5198†† 170M5248<br>900 360,000 1,750,000 N/A 135 170M5149†† 170M5199†† 170M5249††<br>1100 Vac (IEC/UL)<br>1000 480,000 2,350,000 N/A 145 170M5150†† 170M5200†† 170M5250††<br>315 9500 58,000 77,500 85 170M6138†† 170M6188†† 170M6238††<br>350 13,500 81,500 110,000 90 170M6139†† 170M6189†† 170M6239††<br>400 19,500 120,000 160,000 95 170M6140†† 170M6190†† 170M6240††<br>450 31,000 185,000 245,000 100 170M6141†† 170M6191†† 170M6241††<br>500 39,000 235,000 310,000 105 170M6142†† 170M6192†† 170M6242††<br>550 55,000 325,000 435,000 110 170M6143†† 170M6193†† 170M6243††<br>1300 Vac (UL)<br>630 83,500 495,000 665,000 115 170M6144†† 170M6194†† 170M6244††<br>3<br>700 115,000 705,000 940,000 120 170M6145†† 170M6195†† 170M6245††<br>800 205,000 995,000 1,300,000 125 170M6146††† 170M6196††† 170M6246 [1]<br>900 305,000 1,500,000 1,900,000 130 170M6147††† 170M6197††† 170M6247 [1]<br>1000 450,000 2,150,000 2,750,000 135 170M6148††† 170M6198††† 170M6248 [1]<br>1100 575,000 2,800,000 3,600,000 160 170M6149††† 170M6199††† 170M6249 [1]<br>1250 810,000 3,950,000 N/A 170 170M6150 [1] ,†† 170M6200 [1] 170M6250 [1]<br>1100 Vac (IEC)<br>1400 1,250,000 6,000,000 N/A 175 170M6151 [1] ,†† 170M6201 [1] 170M6251 [1]<br>**----- End of picture text -----**<br>
- Watts loss at rated current.
- †† DC voltage rated at 900 Vdc, UL Recognized, File E125085.
- ††† DC voltage rated at 1000 Vdc, UL Recognized, File E125085.
- 1 Not UL Recognized.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6630 (Size 1*), 170K6632 (Size 1), 170K6634 (Size 2), 170K6636 (Size 3)
Eaton.com/bussmannseries
4-46
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 00 to 3, DIN 43620, full range (gR)
690 Vac (IEC), 10 to 800 A
Square body DIN 43653 blade high speed fuses. Full range protection fuses provide both overload and short-circuit protection. Fuses come with Type T indicator for a microswitch.
Ratings
- Volts 690 Vac (IEC)
- Amps 10-800 A
- IR 200 kA RMS Sym.
Operating class gR
Agency information
- Designed and tested to IEC 60269 Part 4
> • CE
Dimensions — mm
**==> picture [263 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|ee|Size|A|B|D (max)|E (max)|F|G|H (min)|
|00|49|78.5|60|30|35|6|15|
|1|68|135|66|52|40|6|20|
|2|68|150|74|60|48|6|25|
|3|68|150|89|75|60|6|32|
**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6412 (Size 00), 170K6416 (Size 1), 170K6418 (Size 2), 170K6420 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-47
**4 — High speed fuses**
170M — Square Body size 00 to 3, DIN 43620, full range (gR)
690 Vac (IEC), 10 to 800 A
**==> picture [537 x 512] intentionally omitted <==**
**----- Start of picture text -----**<br>
I²t (A²s) Watts<br>Fuse loss Catalog no.<br>size Rated voltage Rated current (amps) [1] Pre-arcing Clearing at 690 Vac (W)† - Type T indicator for microswitch<br>10 3.8 20 3.5 170M2691<br>16 7.2 38 5.5 170M2692<br>20 13.0 70 6.0 170M2693<br>25 24.0 125 8.0 170M2694<br>32 53.0 275 9.0 170M2695<br>40 95.0 490 10.0 170M2696<br>00 690 Vac (IEC)<br>50 185.0 1000 11.0 170M2697<br>63 345.0 1800 14.0 170M2698<br>80 695.0 3600 16.0 170M2699<br>100 1250.0 6650 19.0 170M2700<br>125 2300.0 12,000 23.0 170M2701<br>160 4350.0 22,500 29.0 170M2702<br>50 135.0 705 12.0 170M4176<br>63 245.0 1300 15.0 170M4177<br>80 500.0 2600 17.0 170M4178<br>100 950.0 4850 20.0 170M4179<br>125 1850.0 9500 23.0 170M4180<br>1 690 Vac (IEC) 160 3450.0 18,000 28.0 170M4181<br>200 6750.0 34,500 31.0 170M4182<br>250 13,500.0 70,500 35.0 170M4183<br>315 26,000.0 135,000 41.0 170M4184<br>350 34,000.0 175,000 45.0 170M4185<br>400 48,500.0 250,000 48.0 170M4186<br>200 5650.0 29,000 33.0 170M5881<br>250 10,000.0 52,500 40.0 170M5882<br>315 19,500.0 105,000 46.0 170M5883<br>350 26,000.0 135,000 50.0 170M5884<br>2 690 Vac (IEC) 400 39,500.0 205,000 53.0 170M5885<br>450 55,500.0 290,000 59.0 170M5886<br>500 73,000.0 375,000 66.0 170M5887<br>550 100,000.0 515,000 70.0 170M5888<br>630 150,000.0 770,000 79.0 170M5889<br>350 23,000.0 120,000 55.0 170M6080<br>400 34,000.0 175,000 59.0 170M6081<br>450 48,500.0 250,000 62.0 170M6082<br>500 64,000.0 330,000 67.0 170M6083<br>3 690 Vac (IEC)<br>550 84,500.0 435,000 70.0 170M6084<br>630 125,000.0 645,000 85.0 170M6085<br>700 160,000.0 840,000 93.0 170M6086<br>800 245,000.0 1,300,000 99.0 170M6087<br>**----- End of picture text -----**<br>
- Watts loss at rated current.
1 The RMS Amp rating of this fuses range is given with open fuse blocks connected to copper conductors according to IEC 60269, Part 1, table 10. When used in enclosed fuse blocks/disconnects, derating factors have to be observed. Please contact Eaton's Bussmann Division for application assistance bulehighspeedtechnical@ eaton.com.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6412 (Size 00), 170K6416 (Size 1), 170K6418 (Size 2), 170K6420 (Size 3)
Eaton.com/bussmannseries
4-48
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 000 to 3, DIN 43620, dual indicator fuses
690 Vac (IEC), 700 Vac (UL), 10 to 1600 A
Square body DIN 43620 blade high speed fuses with dual indicator system: one indicator in the fuse body and another one in the metallic end plate. Interchangeable with existing high speed DIN 43620 fuses for the protection of UPS, soft starters, solid state relays, variable speed drives, rectifiers and inverters.
## Ratings
- Volts
- 690 Vac (IEC)
- 700 Vac (UL)
- Amps 10-1600 A
- IR 200 kA RMS Sym.
## Operating class
- gR (size 000, 10-63 A)
- aR (others)
Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085
- CSA Class 1422-30, (53787) with the exception of catalog number 170M4867D
> • CE
Dimensions — mm
**==> picture [255 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Size|A|B|C|D|E|F|G|H|J|K|
|000|78.5|53.0|15.0|52|35|10|49.7|1.5|6|20.5|
|00|78.5|53.0|15.0|59|35|10|49.7|2.0|6|30.0|
|1|135.0|71.4|20.0|64|40|10|67.5|2.0|6|40.0|
|2|150.0|71.4|25.1|72|48|10|67.5|2.0|6|54.0|
|3|150.0|72.4|32.0|87|60|10|68.5|2.5|6|71.0|
**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6386 (Size 000 and 00), 170K6388 (Size 1), 170K6390 (Size 2), 170K6392 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-49
**4 — High speed fuses**
170M — Square Body size 000 to 3, DIN 43620, dual indicator fuses
690 Vac (IEC), 700 Vac (UL), 10 to 1600 A
**==> picture [483 x 591] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated I [2] t (A [2] s)<br>current Max permissible Watts<br>Fuse size Rated voltage (amps) load current Pre-arcing Clearing at 690 Vac loss (W) [3] Catalog no.<br>10 10 4 27 2.5 170M1558D<br>16 16 7 51 4 170M1559D<br>20 20 11.5 82.5 5 170M1560D<br>25 25 19 140 6 170M1561D<br>32 32 40 285 7 170M1562D<br>40 40 65 490 8.5 170M1563D<br>690 Vac (IEC) 50 50 115 815 9.5 170M1564D<br>000<br>700 Vac (UL) 63 63 215 1550 11.5 170M1565D<br>80 80 380 2700 15 170M1566D<br>100 100 695 4950 16.5 170M1567D<br>125 125 1180 8250 21.5 170M1568D<br>160 160 2300 16,500 25 170M1569D<br>200 200 4350 31,000 29.5 170M1570D<br>250 250 7900 56,000 35.5 170M1571D<br>00 690 Vac (IEC) /700 Vac (UL) 315 315 12,000 84,500 45 170M1572D<br>40 25 40 285 4 170M3808D<br>50 30 78 550 4.5 170M3809D<br>63 38 120 850 6.5 170M3810D<br>80 50 185 1350 8.5 170M3811D<br>100 60 360 2600 10 170M3812D<br>125 75 550 3900 11 170M3813D<br>160 95 1150 8250 12 170M3814D<br>200 120 2300 16,500 12.5 170M3815D<br>1 690 Vac (IEC) 250 150 4350 31,000 16 170M3816D<br>700 Vac (UL)<br>315 190 7300 52,000 20 170M3817D<br>350 210 10,000 73,000 21.5 170M3818D<br>400 240 16,000 115,000 23 170M3819D<br>450 270 21,500 155,000 26.5 170M4863D<br>500 300 27,000 190,000 28.5 170M4864D<br>550 330 33,500 240,000 33 170M4865D<br>630 380 48,500 345,000 37.5 170M4866D<br>700 420 69,500 495,000 39 170M4867D [1]<br>400 240 11,000 79,000 29 170M5808D<br>450 270 16,000 115,000 32 170M5809D<br>500 300 21,500 155,000 34 170M5810D<br>550 330 29,000 215,000 36 170M5811D<br>690 Vac (IEC) 630 380 41,000 295,000 42 170M5812D<br>2<br>700 Vac (UL) 700 420 60,500 430,000 43 170M5813D<br>800 480 86,000 610,000 48 170M5814D<br>900 540 125,000 895,000 52 170M5820D<br>1000 600 180,000 1,300,000 53 170M5816D<br>1100 660 245,000 1,750,000 56 170M5817D<br>500 300 14,000 99,500 43 170M6808D<br>550 330 19,500 140,000 44 170M6809D<br>630 380 31,000 220,000 45 170M6810D<br>700 420 45,000 320,000 46 170M6811D<br>800 480 69,500 490,000 48 170M6812D<br>690 Vac (IEC) 900 540 100,000 720,000 50 170M6813D<br>3<br>700 Vac (UL) 1000 600 140,000 985,000 56 170M6814D<br>1100 660 190,000 1,400,000 57 170M6892D<br>1250 750 300,000 2,150,000 61 170M8554D<br>1400 840 380,000 2,700,000 70 170M8555D<br>1500 900 470,000 3,350,000 72 170M8556D<br>1600 960 585,000 4,150,000 74 170M8557D<br>**----- End of picture text -----**<br>
- 1 170M4867D is not UL Recognized.
- 3 Given at maximum load rated current, please refer to data sheets for further details.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6386 (Size 000 and 00), 170K6388 (Size 1), 170K6390 (Size 2), 170K6392 (Size 3)
Eaton.com/bussmannseries
4-50
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## a
## 170M — Square Body size 00, DIN 43620
1000 Vac (IEC and UL), 20 to 225 A
Square body DIN 43620 blade style high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Fuses come with Type T indicator for microswitches.
Ratings
- Volts
- 1000 Vac (IEC and UL)
- 900 Vac (200 and 225 A)
- Amps 20-225 A
- IR 125 kA RMS Sym.
Operating class aR
Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized (20-160 A)
- CSA (20-160 A)
- CE
|||I²t (A²s)|Catalog no. with|
|---|---|---|---|
|Fuse size<br>Rated voltage|Rated current (amps)|Pre-arcing<br>Clearingat 1000 Vac|Watts loss (W)†<br>Type T indicator<br>for microswitch|
||20|15<br>110|8.5<br>170M2673|
||25|28.5<br>210|9.5<br>170M2674|
||32|53<br>390|11<br>170M2675|
||35|69<br>500|12<br>170M2676|
||40|105<br>760|13<br>170M2677|
|00<br>1000 Vac (IEC/UL)|50|215<br>1550|14<br>170M2678|
||63|380<br>2750|16<br>170M2679|
||80|815<br>5900|18<br>170M2680|
||100|1550<br>11,500|21<br>170M2681|
||125|3000<br>22,000|23<br>170M2682|
||160|6250<br>45,000|26<br>170M2683|
|00<br>900 Vac (IEC)|200<br>225|12,000<br>86,500<br>18,000<br>115,000|31<br>170M2684<br>33<br>170M2685|
- Watts loss at rated current.
## Dimensions — mm
**==> picture [194 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
47.5 20.0<br>10.0<br>2.5<br>Pr 7<br>Indicator<br>60 35.0<br>15.0 48<br>Lt}1 fy<br>52.0<br>78.5<br>| — |<br>boy<br>6.0 30.0<br>fF,<br>**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for Data sheet no. 170K8506
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-51
## **4 — High speed fuses**
## 170M — Square Body size 1* to 3, French style
690 Vac (IEC), 700 Vac (UL), 40 to 1600 A
Square body French style high speed fuses for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Available with Type T or K indicators for microswitches.
## Ratings
- Volts
- 690 Vac (IEC)
- 700 Vac (UL)
- Amps 40-1600 A
- IR 200 kA RMS Sym.
## Operating class aR
Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085
- CSA Class 1422-30, (53787) on sizes (1, 2, 3) only
- CCC (please consult bulehighspeedtechnical@eaton.com for status)
- CE
Dimensions — mm
Type -E/-, -EKN/-
**==> picture [250 x 54] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Size|A|B|C|D|E|H|J|K|
|1*|50|102|76|59|45|18|9|13|
|1|50|111|86|69|53|25|11|11|
|2|50|126|91|77|61|30|13|12|
|3|51|126|91|92|76|36|13|13|
**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6314 (Size 1*), 170K6316 (Size 1), 170K6318 (Size 2), 170K6320 (Size 3)
Eaton.com/bussmannseries
4-52
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M —Square Body size 1* to 3, French style
690 Vac (IEC), 700 Vac (UL), 40 to 1600 A
**==> picture [563 x 589] intentionally omitted <==**
**----- Start of picture text -----**<br>
I²t (A²s) Watts Catalog no.<br>Rated Rated current Clearing at loss -E/- Type T indicator for -EKN/- Type K indicator for<br>Fuse size voltage (amps) Pre-arcing 660 Vac (W)† microswitch microswitch<br>40 40 270 9 170M3308 170M3358<br>50 77 515 11 170M3309 170M3359<br>63 115 770 14 170M3310 170M3360<br>80 185 1250 18 170M3311 170M3361<br>100 360 2450 21 170M3312 170M3362<br>125 550 3700 26 170M3313 170M3363<br>690 Vac (IEC) 160 1100 7500 30 170M3314 170M3364<br>1*<br>700 Vac (UL) 200 2200 15,000 35 170M3315 170M3365<br>250 4200 28,500 40 170M3316 170M3366<br>315 7000 46,500 50 170M3317 170M3367<br>350 10,000 68,500 55 170M3318 170M3368<br>400 15,000 105,000 60 170M3319 170M3369<br>450 21,000 140,000 65 170M3320 170M3370<br>500 27,000 180,000 70 170M3321 170M3371<br>200 1650 11,500 45 170M4308 170M4358<br>250 3100 21,000 55 170M4309 170M4359<br>315 6200 42,000 58 170M4310 170M4360<br>350 8500 59,000 60 170M4311 170M4361<br>400 13,500 91,500 65 170M4312 170M4362<br>690 Vac (IEC)<br>1 450 17,000 120,000 70 170M4313 170M4363<br>700 Vac (UL) 500 25,000 170,000 72 170M4314 170M4364<br>550 34,000 230,000 75 170M4315 170M4365<br>630 52,000 350,000 80 170M4316 170M4366<br>700 69,500 465,000 85 170M4317 170M4367<br>800 105,000 725,000 95 170M4318 170M4368<br>400 11,000 74,000 65 170M5308 170M5358<br>450 15,500 105,000 70 170M5309 170M5359<br>500 21,500 145,000 75 170M5310 170M5360<br>550 28,000 190,000 80 170M5311 170M5361<br>690 Vac (IEC)<br>2 630 41,000 275,000 90 170M5312 170M5362<br>700 Vac (UL)<br>700 60,500 405,000 95 170M5313 170M5363<br>800 86,000 575,000 105 170M5314 170M5364<br>900 125,000 840,000 110 170M5315 170M5365<br>1000 180,000 1,250,000 115 170M5316 170M5366<br>500 14,000 95,000 95 170M6308 170M6358<br>550 19,500 135,000 100 170M6309 170M6359<br>630 31,000 210,000 105 170M6310 170M6360<br>700 44,500 300,000 110 170M6311 170M6361<br>800 69,500 465,000 115 170M6312 170M6362<br>690 Vac (IEC) 900 100,000 670,000 120 170M6313 170M6363<br>3<br>700 Vac (UL) 1000 140,000 945,000 125 170M6314 170M6364<br>1100 190,000 1,300,000 130 170M6315 170M6365<br>1250 290,000 1,950,000 140 170M6316 170M6366<br>1400 370,000 2,450,000 155 170M6317 170M6367<br>1500 460,000 3,100,000 160 170M6318 170M6368<br>1600 580,000 3,900,000 160 170M6319 170M6369<br>High speed fuses<br>**----- End of picture text -----**<br>
- Watts loss at rated current.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6314 (Size 1*), 170K6316 (Size 1), 170K6318 (Size 2), 170K6320 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-53
## **4 — High speed fuses**
## 170M — Square Body size 1* to 3, US style
690 Vac (IEC), 700 Vac (UL), 40 to 2000 A
Square body US style bolted tags high speed fuses for the protection of DC common bus, DC drives, power converters/ rectifiers and reduced rated voltage starters. Available with Type K indicator for a microswitch.
## Ratings
- Volts
- 500 to 700 Vac (see catalog number table)
- 750 Vdc (UL, see catalog number table for specific fuses)
- Amps 40-2000 A
- IR 200 kA RMS Sym.
## Operating class aR
## Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2*, E125085
- CSA Class 53787, File 1422-30*
- CCC*
## • CE
- Consult your Bussmann series product representative for status.
## Dimensions — mm
1mm = 0.0394”
**==> picture [263 x 243] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|B|
|G|
|—|||+]i|D|7|
|ee|E|*|
|A|
|C1|
|C2|
|J|H|
|“To!|=.|
|Type -FU/-, -FKE/-, FU/115-, -FKE/115|
|Size|A|B|B1|C1|C1|[†]|C2|C2|[†]|D|E|G|H|J|
|ee|
|1*|50|110|148|85|123|72|110|59|45|6|20|10|
|1|50|136|157|104|126|78|100|69|53|6|25|14|
|2|50|135|159|105|125|78|99|77|61|6|25|14|
|3|51|135|155|106|125|77|97|92|76|6|36|16|
**----- End of picture text -----**<br>
- Valid for fuss types -FU/115 and -FKE/115.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6314 (Size 1*), 170K6316 (Size 1), 170K6318 (Size 2), 170K6320 (Size 3)
Eaton.com/bussmannseries
4-54
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
170M — Square Body size 1* to 3, US style
690 Vac (IEC), 700 Vac (UL), 40 to 2000 A
**==> picture [537 x 614] intentionally omitted <==**
**----- Start of picture text -----**<br>
I²t (A²s) Catalog no.<br>Rated -FKE/- Type K indi- -FKE/115 Type<br>Fuse current Clearing at Watts -FU/- without cator for micros- -FU/115 without K indicator for<br>size Rated voltage (amps) Pre-arcing 660 Vac loss (W)† indicator witch indicator microswitch<br>40 40 270 9 170M3608 170M3658 170M3708 170M3758<br>50 70 515 11 170M3609 170M3659 170M3709 170M3759<br>63 115 770 14 170M3610 170M3660 170M3710 170M3760<br>80 185 1250 18 170M3611 170M3661 170M3711 170M3761<br>100 360 2450 21 170M3612 170M3662 170M3712 170M3762<br>125 550 3700 26 170M3613 170M3663 170M3713 170M3763<br>160 1100 7500 30 170M3614 170M3664 170M3714 170M3764<br>1* 690 Vac (IEC) 200 2200 15,000 35 170M3615 170M3665 170M3715 170M3765<br>700 Vac (UL) 250 4200 28,500 40 170M3616 170M3666 170M3716 170M3766<br>315 7000 46,500 50 170M3617 170M3667 170M3717 170M3767<br>350 10,000 68,500 55 170M3618 170M3668 170M3718 170M3768<br>400 15,000 105,000 60 170M3619 170M3669 170M3719 170M3769<br>450 21,000 140,000 65 170M3620 170M3670 170M3720 170M3770<br>500 27,000 180,000 70 170M3621 170M3671 170M3721 170M3771<br>550 34,000 230,000 75 170M3622 170M3672 170M3722 170M3772<br>630 48,500 325,000 80 170M3623 170M3673 170M3723 170M3773<br>200 1650 11,500 45 170M4608 170M4658 170M4708 170M4758<br>250 3100 21,000 55 170M4609 170M4659 170M4709 170M4759<br>315 6200 42,000 58 170M4610 170M4660 170M4710 170M4760<br>350 8500 59,000 60 170M4611 170M4661 170M4711 170M4761<br>690 Vac (IEC) 400 13,500 91,500 65 170M4612 170M4662 170M4712 170M4762<br>1 700 Vac (UL) 450500 1725,,000000 120170,,000000 7072 170M4613170M4614 170M4663170M4664 170M4713170M4714 170M4763170M4764<br>550 34,000 230,000 75 170M4615 170M4665 170M4715 170M4765<br>630 52,000 350,000 80 170M4616 170M4666 170M4716 170M4766<br>700 69,500 465,000 85 170M4617 170M4667 170M4717 170M4767<br>800 105,000 725,000 95 170M4618 170M4668 170M4718 170M4768<br>550 Vac (IEC) 900 155,000 850,000 100 170M4619 170M4669 170M4719 170M4769<br>400 11,000 74,000 65 170M5608 170M5658 170M5708 170M5758<br>450 15,500 105,000 70 170M5609 170M5659 170M5709 170M5759<br>500 21,500 145,000 75 170M5610 170M5660 170M5710 170M5760<br>690 Vac (IEC) 550 28,000 190,000 80 170M5611 170M5661 170M5711 170M5761<br>630 41,000 275,000 90 170M5612 170M5662 170M5712 170M5762<br>2 700 Vac (UL) 700 60,500 405,000 95 170M5613 170M5663 170M5713 170M5763<br>800 86,000 575,000 105 170M5614 170M5664 170M5714 170M5764<br>900 125,000 840,000 110 170M5615 170M5665 170M5715 170M5765<br>1000 180,000 1,250,000 115 170M5616 170M5666 170M5716 170M5766<br>600 Vac (IEC) 1100 245,000 1,600,000 120 170M5617 170M5667 170M5717 170M5767<br>1250 365,000 2,400,000 130 170M5618 170M5668 170M5718 170M5768<br>700 Vac (UL)<br>500 14,000 95,000 95 170M6608 170M6658 170M6708 170M6758<br>550 19,500 135,000 100 170M6609 170M6659 170M6709 170M6759<br>630 31,000 210,000 105 170M6610 170M6660 170M6710 170M6760<br>700 44,500 300,000 110 170M6611 170M6661 170M6711 170M6761<br>800 69,500 465,000 115 170M6612 170M6662 170M6712 170M6762<br>690 Vac (IEC) 900 100,000 670,000 120 170M6613 170M6663 170M6713 170M6763<br>700 Vac (UL) 1000 140,000 945,000 125 170M6614 170M6664 170M6714 170M6764<br>3 1100 190,000 1,300,000 130 170M6615 170M6665 170M6715 170M6765<br>1250 290,000 1,950,000 140 170M6616 170M6666 170M6716 170M6766<br>1400 370,000 2,450,000 155 170M6617 170M6667 170M6717 170M6767<br>1500 460,000 3,100,000 160 170M6618 170M6668 170M6718 170M6768<br>1600 580,000 3,900,000 160 170M6619 170M6669 170M6719 170M6769<br>600 Vac (IEC)<br>1800 880,000 5,250,000 165 170M6620†† 170M6670 [1] 170M6720†† 170M6770<br>500 Vac (UL)<br>550 Vac (IEC)<br>2000 1,150,000 6,350,000 175 170M6621 170M6671 [2] 170M6721 170M6771<br>500 Vac (UL)<br>**----- End of picture text -----**<br>
- Watts loss at rated current.
- †† DC voltage rated at 750 Vdc, UL Recognized, File E125085.
- 1 170M6670 600 Vac (IEC)/550 Vac.
- 2 170M6671 550 Vac (IEC and UL).
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6314 (Size 1*), 170K6316 (Size 1), 170K6318 (Size 2), 170K6320 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-55
## **4 — High speed fuses**
## 170M — Square Body size 1* to 3, US style
1000 Vac (IEC), 50 to 1400 A
Square body US style bolted tags high speed fuses for the protection of DC common bus, DC drives, power converters/ rectifiers and reduced rated voltage starters. Fuses come with Type K indicator for microswitches.
## Ratings
- Volts 1000 Vac (IEC) (1400 A 900 Vac)
- Amps 50-1400 A
- IR 125 kA RMS Sym.
Operating class aR
## Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085 for size 2 and 3 (315-1100 A)
- CSA Class 53787, File 1422-30 for size 2 and 3 (315-1100 A)
- CCC approval for size 2 only
> • CE
## Dimensions — mm
1mm = 0.0394”
|Size<br>A|B|C|D|F|G|H|I|K|
|---|---|---|---|---|---|---|---|---|
|1*FKE/115<br>74|101.0|130.0|156|43|60|10.4|20|6|
|1FKE/115<br>76|102.0|128.0|160|51|68|14.3|25|6|
|2FKE/115<br>76|101.1|127.5|160|59|76|14.4|25|6|
|3FKE/115<br>76|101.1|127.5|158|74|91|16.0|36|6|
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K8564 (Size 1*), 170K8566 (Size 1), 170K8568 (Size 2), 170K8570 (Size 3)
Eaton.com/bussmannseries
4-56
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 1* to 3, US style, 170M
1000 Vac (IEC), 50 to 1400 A
**==> picture [561 x 572] intentionally omitted <==**
**----- Start of picture text -----**<br>
I²t (A²s) Catalog no.<br>Watts -FKE/115 Type K indicator for<br>Fuse size Rated voltage Rated current (amps) Pre-arcing Clearing at 1000 Vac loss (W)† microswitch<br>50 135 815 20 170M3531<br>63 215 1300 25 170M3532<br>80 460 2750 30 170M3533<br>100 860 5100 35 170M3534<br>125 1450 8600 40 170M3535<br>1* 1000 Vac (IEC) 160 2850 17,500 45 170M3536<br>200 4950 29,500 50 170M3537<br>250 9550 57,000 55 170M3538<br>315 21,500 130,000 65 170M3539<br>350 29,000 175,000 70 170M3540<br>400 42,000 250,000 75 170M3541<br>160 2200 13,500 40 170M4531<br>200 4150 24,500 50 170M4532<br>250 7750 46,000 55 170M4533<br>315 16,500 98,500 65 170M4534<br>350 21,500 130,000 70 170M4535<br>1 1000 Vac (IEC)<br>400 31,000 185,000 75 170M4536<br>450 44,500 265,000 80 170M4537<br>500 63,000 375,000 85 170M4538<br>550 84,500 500,000 90 170M4539<br>630 125,000 755,000 98 170M4540<br>250 6750 40,000 65 170M5531<br>315 13,500 81,500 75 170M5532<br>350 16,500 99,000 80 170M5533<br>400 26,000 155,000 85 170M5534<br>450 35,500 210,000 90 170M5535<br>2 1000 Vac (IEC/UL)<br>500 49,500 295,000 95 170M5536<br>550 66,000 390,000 100 170M5337<br>630 93,500 555,000 110 170M5538<br>700 130,000 770,000 115 170M5539<br>800 195,000 1,200,000 125 170M5540<br>315 9200 54,500 90 170M8531<br>350 13,000 77,500 95 170M8532<br>400 19,000 115,000 105 170M8533<br>450 27,000 160,000 107 170M8534<br>500 37,500 225,000 110 170M8535<br>550 52,000 310,000 115 170M8536<br>1000 Vac (IEC/UL)<br>630 82,500 490,000 120 170M8537<br>3<br>700 115,000 700,000 125 170M8538<br>800 170,000 1,050,000 135 170M8539<br>900 250,000 1,500,000 145 170M8540<br>1000 340,000 2,050,000 150 170M8541<br>1100 460,000 2,750,000 155 170M8542<br>1000 Vac (IEC) 1250 575,000 3,400,000 175 170M8543<br>900 Vac (IEC) 1400 795,000 4,200,000 185 170M8544<br>High speed fuses<br>**----- End of picture text -----**<br>
† Watts loss at rated current.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K8564 (Size 1*), 170K8566 (Size 1), 170K8568 (Size 2), 170K8570 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-57
**4 — High speed fuses**
## 170M — Square Body size 1* to 3, US style
1250 Vac (IEC), 1300 Vac (UL), 50 to 1400 A
Square body US style bolted tags high speed fuses for the protection of DC common bus, DC drives, power converters/ rectifiers and reduced rated voltage starters. Available with Type K indicator for microswitches.
## Ratings
- Volts
- 1250 Vac (IEC)
- 1300 Vac (UL)
- 900 Vdc (UL, see catalog number table for specific fuses)
- Amps 50-1400 A
- IR 100 kA RMS Sym.
Operating class aR
## Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized[†]
- CSA[†]
- CCC[†]
## • CE
- Consult your Bussmann series product representative for status.
## Dimensions — mm
**==> picture [206 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
<—___________ B<br>G<br>q li D ;<br>IL E 7<br>A<br>**----- End of picture text -----**<br>
|||C2<br>C1<br>i=|C2<br>C1<br>i=|C2<br>C1<br>i=|C2<br>C1<br>i=|C2<br>C1<br>i=|C2<br>C1<br>i=|C2<br>C1<br>i=|C2<br>C1<br>i=|C2<br>C1<br>i=|C2<br>C1<br>i=|C2<br>C1<br>i=|C2<br>C1<br>i=|C2<br>C1<br>i=|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||||||||||
|||||||||||||||||||J|H||
||||||||||||||||||||||
||||||||||||||||||||||
|Type-FU/115,-FKE/115|||||||||||||||||||||
|Size<br>A<br>B<br>C1|||C2||||D||E|||G||||H||J|||
|1*<br>74<br>156<br>130|||101||59||||45|||6|||20|||10|||
|1<br>76<br>160<br>127|||102||69||||53|||6|||25|||14|||
|2<br>76<br>160<br>127|||102||77||||61|||6|||25|||14|||
|3<br>76<br>159<br>128|||101||92||||76|||6|||36|||16|||
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6630 (Size 1*), 170K6632 (Size 1), 170K6634 (Size 2), 170K6636 (Size 3)
Eaton.com/bussmannseries
4-58
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
170M — Square Body size 1* to 3, US style
1250 Vac (IEC), 1300 Vac (UL), 50 to 1400 A
**==> picture [562 x 608] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated I²t (A²s) Catalog no.<br>Fuse current Clearing at Clearing at Watts -FU/115 -FKE/115 Type K indicator<br>size Rated voltage (amps) Pre-arcing 1000 Vac 1250 Vac loss (W)† without indicator for microswitch<br>50 135 815 1100 15 170M3688†† 170M3738††<br>63 215 1300 1750 20 170M3689†† 170M3739††<br>80 420 2500 3350 25 170M3690†† 170M3740††<br>100 750 4450 5950 30 170M3691†† 170M3741††<br>1250 Vac (IEC) 125 1450 9000 11,500 35 170M3692†† 170M3742††<br>1*<br>1300 Vac (UL) 160 2600 16,000 21,000 40 170M3693†† 170M3743††<br>200 5150 31,000 41,000 45 170M3694†† 170M3744††<br>250 9200 54,500 73,000 55 170M3695†† 170M3745††<br>315 18,500 115,000 150,000 60 170M3696†† 170M3746††<br>350 27,000 165,000 220,000 65 170M3697†† 170M3747††<br>160 1900 11,500 15,500 45 170M4688 170M4738<br>200 3800 22,500 30,000 50 170M4689 170M4739<br>250 7750 46,000 61,500 60 170M4690 170M4740<br>1250 Vac (IEC)<br>315 15,000 90,000 120,000 65 170M4691 170M4741<br>1300 Vac (UL)<br>350 20,000 125,000 165,000 70 170M4692 170M4742<br>1<br>400 29,500 175,000 235,000 75 170M4693 170M4743<br>450 42,000 250,000 335,000 80 170M4694 170M4744<br>500 69,500 340,000 N/A 85 170M4695 170M4745<br>1100 Vac IEC<br>550 95,000 465,000 N/A 95 170M4696 170M4746<br>1000 Vac IEC 630 130,000 660,000 N/A 100 170M4697 170M4747<br>250 6500 38,500 51,500 65 170M5688 170M5738<br>280 9350 55,500 74,500 70 170M5689 170M5739<br>315 13,000 77,500 105,000 75 170M5690 170M5740<br>350 16,500 97,500 135,000 80 170M5691 170M5741<br>1250 Vac (IEC)<br>400 23,000 140,000 180,000 85 170M5692 170M5742<br>1300 Vac (UL)<br>450 34,000 205,000 270,000 90 170M5693 170M5743<br>2 500 48,000 285,000 380,000 95 170M5694 170M5744<br>550 62,000 370,000 495,000 100 170M5695 170M5745<br>630 115,000 575,000 730,000 120 170M5696 170M5746<br>700 160,000 795,000 N/A 125 170M5697 170M5747<br>1100 Vac IEC<br>800 245,000 1,200,000 N/A 130 170M5698 170M5748<br>900 360,000 1,750,000 N/A 135 170M5699 170M5749<br>1000 Vac IEC<br>1000 480,000 2,350,000 N/A 145 170M5700 170M5750<br>315 9500 58,000 77,500 85 170M6688 170M6738<br>350 13,500 81,500 110,000 90 170M6689 170M6739<br>400 19,000 120,000 160,000 95 170M6690 170M6740<br>1250 Vac (IEC) 450 31,000 185,000 245,000 100 170M6691 170M6741<br>1300 Vac (UL) 500 39,000 235,000 310,000 105 170M6692 170M6742<br>550 55,000 325,000 435,000 110 170M6693 170M6743<br>630 83,500 495,000 665,000 115 170M6694 170M6744<br>3 700 115,000 705,000 940,000 120 170M6695 170M6745<br>800 205,000 995,000 1,300,000 125 170M6696 170M6746<br>1250 Vac (IEC)<br>900 305,000 1,500,000 1,900,000 130 170M6697 170M6747<br>1100 Vac (IEC) 1000 450,000 2,150,000 N/A 135 170M6698 170M6748<br>1000 Vac (UL) 1100 575,000 2,800,000 N/A 160 170M6699 170M6749<br>1250 810,000 3,950,000 N/A 170 170M6700 170M6750<br>1000 Vac (IEC/UL)<br>1400 1,250,000 6,000,000 N/A 175 170M6701 170M6751<br>High speed fuses<br>**----- End of picture text -----**<br>
† Watts loss at rated current.
†† DC voltage rated at 900 Vdc, UL Recognized, File E125085.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6630 (Size 1*), 170K6632 (Size 1), 170K6634 (Size 2), 170K6636 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-59
## **4 — High speed fuses**
## 170M — Square Body size 00, flush-end contact
## 690 Vac, 25 to 400 A
Square body flush-end contact high speed fuses, for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Catalog numbers available with visual indicator and Type T indicator for a microswitch.
## Ratings
- Volts 690 Vac (IEC)
- Amps 25-400 A
- IR 200 kA RMS Sym.
## Operating class
- gR (25-80 A)
- aR (100-400 A)
## Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085
- CSA Class 53787, File 1422-30 on size 000
- CE
|Fuse<br>size<br>Rated voltage|Rated<br>current<br>(amps)|I²t (A²s)<br>Pre-arcing<br>Clearingat 660 Vac|Watts<br>loss<br>(W)†|Catalogno.<br>00B/60 visual indicator<br>00BTN/60 Type T indicator for<br>microswitch|
|---|---|---|---|---|
||25|19.0<br>130|6|170M2708<br>170M2758|
||32|28.5<br>195|7|170M2709<br>170M2759|
||40|50.0<br>360|9|170M2710<br>170M2760|
||50|95.0<br>640|10|170M2711<br>170M2761|
||63|170.0<br>1200|12|170M2712<br>170M2762|
||80|310.0<br>2100|15|170M2713<br>170M2763|
|00<br>690 Vac (IEC)|100<br>125|620.0<br>4150<br>1000.0<br>6950|20<br>25|170M2714<br>170M2764<br>170M2715<br>170M2765|
||160|1900.0<br>13,000|30|170M2716<br>170M2766|
||200|3400.0<br>23,000|35|170M2717<br>170M2767|
||250|6250.0<br>42,000|45|170M2718<br>170M2768|
||315|10,000.0<br>68,500|55|170M2719<br>170M2769|
||350|13,500.0<br>91,500|60|170M2720<br>170M2770|
||400|18,000.0<br>125,000|70|170M2721<br>170M2771|
- Watts loss at rated current.
Dimensions — mm
**==> picture [231 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
Indicator<br>a Ø16 e _<br>30<br>48<br>64 54 62<br>kwon<br>- fo]<br>6<br>Litt»<br>M8 P| ke<br>**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for Data sheet no. 170K6312
Eaton.com/bussmannseries
4-60
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 1* to 3, flush-end contact
690 Vac (IEC), 700 Vac (UL), 40 to 2000 A
Square body flush-end contact high speed fuses, for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Catalog numbers available with visual indicator and Type K indicator for a microswitch.
Ratings
- Volts
- 500 to 700 Vac (see catalog number table)
- 750 Vdc (UL, see catalog number table for specific fuses)
- Amps 40-2000 A
- IR 200 kA RMS Sym.
Operating class aR
Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085[†]
- CSA Class 53787, File 1422-30[†]
- CCC[†]
## • CE
- Consult your Bussmann series product representative for status.
Dimensions — mm
Type -B/- , -BKN/- , -G/- , -GKN/-
**==> picture [318 x 76] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|Size|A|B|D|[1]|E|F|F|[2]|(in)|G|H|
|1*|50|51|59|45|M8|5/16-18 UNC-2B|5|N17|
|1|50|51|69|53|M8|5/16-18 UNC-2B|8|N20|
|51 (400-1000 A)|
|2|50|77|61|M10|3/8-16 UNC-2B|10|N24|
|65 (1100-1250 A)|
|53 (500-1500 A)|
|3|51|92|76|M12|1/2-13 UNC-2B|10|N30|
|65 (1600-2000 A)|
**----- End of picture text -----**<br>
- 1 Valid for fuse Types -BKN/ and -GKN/.
- 2 Valid for fuse Types -G- and -GKN/.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6314 (Size 1*), 170K6316 (Size 1), 170K6318 (Size 2), 170K6320 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-61
**4 — High speed fuses**
170M — Square Body size 1* to 3, flush-end contact
690 Vac (IEC), 700 Vac (UL), 40 to 2000 A
**==> picture [537 x 607] intentionally omitted <==**
**----- Start of picture text -----**<br>
I²t (A²s) Catalog no.<br>Rated Watts -BKN/- Type K -GKN/- Type K<br>Fuse Rated current Clearing at loss -B/- visual indicator for -G/- visual indicator for<br>size voltage (amps) Pre-arcing 660 Vac (W) [†] indicator microswitch indicator microswitch<br>40 40 270 9 170M3408 170M3458 170M3508 170M3558<br>50 77 515 11 170M3409 170M3459 170M3509 170M3559<br>63 115 770 14 170M3410 170M3460 170M3510 170M3560<br>80 185 1250 18 170M3411 170M3461 170M3511 170M3561<br>100 360 2450 21 170M3412 170M3462 170M3512 170M3562<br>125 550 3700 26 170M3413 170M3463 170M3513 170M3563<br>160 1100 7500 30 170M3414 170M3464 170M3514 170M3564<br>690 Vac (IEC) 200 2200 15,000 35 170M3415 170M3465 170M3515 170M3565<br>1*<br>700 Vac (UL) 250 4200 28,500 40 170M3416 170M3466 170M3516 170M3566<br>315 7000 46,500 50 170M3417 170M3467 170M3517 170M3567<br>350 10,000 68,500 55 170M3418 170M3468 170M3518 170M3568<br>400 15,000 105,000 60 170M3419 170M3469 170M3519 170M3569<br>450 21,000 140,000 65 170M3420 170M3470 170M3520 170M3570<br>500 27,000 180,000 70 170M3421 170M3471 170M3521 170M3571<br>550 34,000 230,000 75 170M3422 170M3472 170M3522 170M3572<br>630 48,500 325,000 80 170M3423 170M3473 170M3523 170M3573<br>200 1650 11,500 45 170M4408 170M4458 170M4508 170M4558<br>250 3100 21,000 55 170M4409 170M4459 170M4509 170M4559<br>315 6200 42,000 58 170M4410 170M4460 170M4510 170M4560<br>350 8500 59,000 60 170M4411 170M4461 170M4511 170M4561<br>1 690 Vac (IEC)700 Vac (UL) 400450 1317,,500000 12091,,500000 6570 170M4412170M4413 170M4462170M4463 170M4512170M4513 170M4562170M4563<br>500 25,000 170,000 72 170M4414 170M4464 170M4514 170M4564<br>550 34,000 230,000 75 170M4415 170M4465 170M4515 170M4565<br>630 52,000 350,000 80 170M4416 170M4466 170M4516 170M4566<br>700 69,500 465,000 85 170M4417 170M4467 170M4517 170M4567<br>800 105,000 725,000 95 170M4418 170M4468 170M4518 170M4568<br>550 Vac (IEC) 900 155,000 850,000 100 170M4419 170M4469 170M4519 170M4569<br>400 11,000 74,000 65 170M5408 170M5458 170M5508 170M5558<br>450 15,500 105,000 70 170M5409 170M5459 170M5509 170M5559<br>500 21,500 145,000 75 170M5410 170M5460 170M5510 170M5560<br>690 Vac (IEC)700 Vac (UL) 550630 2841,,000000 190275,,000000 8090 170M5411170M5412 170M5461170M5462 170M5511170M5512 170M5561170M5562<br>2 700 60,500 405,000 95 170M5413 170M5463 170M5513 170M5563<br>800 86,000 575,000 105 170M5414 170M5464 170M5514 170M5564<br>900 125,000 840,000 110 170M5415 170M5465 170M5515 170M5565<br>1000 180,000 1,250,000 115 170M5416 170M5466 170M5516 170M5566<br>600 Vac (IEC) 1100 245,000 1,600,000 120 170M5417 170M5467 170M5517 170M5567<br>700 Vac (UL) 1250 365,000 2,400,000 130 170M5418 170M5468 170M5518 170M5568<br>500 14,000 95,000 95 170M6408 170M6458 170M6508 170M6558<br>550 19,500 135,000 100 170M6409 170M6459 170M6509 170M6559<br>630 31,000 210,000 105 170M6410 170M6460 170M6510 170M6560<br>700 44,500 300,000 110 170M6411 170M6461 170M6511 170M6561<br>800 69,500 465,000 115 170M6412 170M6462 170M6512 170M6562<br>690 Vac (IEC) 900 100,000 670,000 120 170M6413 170M6463 170M6513 170M6563<br>700 Vac (UL) 1000 140,000 945,000 125 170M6414 170M6464 170M6514 170M6564<br>3 1100 190,000 1,300,000 130 170M6415 170M6465 170M6515 170M6565<br>1250 290,000 1,950,000 140 170M6416 170M6466 170M6516 170M6566<br>1400 370,000 2,450,000 155 170M6417 170M6467 170M6517 170M6567<br>1500 460,000 3,100,000 160 170M6418 170M6468 170M6518 170M6568<br>1600 580,000 3,900,000 160 170M6419 170M6469 170M6519 170M6569<br>600 Vac (IEC)<br>1800 880,000 5,250,000 165 170M6420†† 170M6470 170M6520†† 170M6570<br>500 Vac (UL)<br>550 Vac (IEC)<br>2000 1,150,000 6,350,000 175 170M6421 170M6471 170M6521 170M6571<br>500 Vac (UL)<br>**----- End of picture text -----**<br>
† Watts loss at rated current.
†† DC voltage rated at 750 Vdc, UL Recognized, File E125085.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6314 (Size 1*), 170K6316 (Size 1), 170K6318 (Size 2), 170K6320 (Size 3)
Eaton.com/bussmannseries
4-62
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 1* to 3, flush-end
## contact
1000 Vac (IEC and UL), 50 to 1400 A
Square body flush-end contact high speed fuses, for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Catalog numbers come with Type K indicator for use with microswitches.
## Ratings
- Volts
- 1000 Vac (IEC, 50-1250 A)
- 1000 Vac (UL, 250-1100 A)
- 900 Vac (IEC, 1400 A
- Amps 50-1400 A
- IR 125 kA RMS Sym.
Operating class aR
Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085 (only sizes 2 and 3 up to 1100 A)
- CE
Dimensions — mm
Type -BKN/- and -GKN/-
|Size<br>Type<br>A<br>B<br>D (max)<br>E<br>F<br>F1(in)<br>G (min)<br>H<br>1*<br>BKN/75 + GKN/75<br>72.5<br>74.0<br>61<br>43<br>M8<br>5/16-18 UNC-2B<br>5<br>17.5<br>~~ee~~|Size<br>Type<br>A<br>B<br>D (max)<br>E<br>F<br>F1(in)<br>G (min)<br>H<br>1*<br>BKN/75 + GKN/75<br>72.5<br>74.0<br>61<br>43<br>M8<br>5/16-18 UNC-2B<br>5<br>17.5<br>~~ee~~|
|---|---|
|1|BKN/75 + GKN/75<br>73.2<br>74.0<br>69<br>52<br>M8<br>5/16-18 UNC-2B<br>8<br>20.0|
|2|BKN/75 + GKN/75<br>73.2<br>74.4<br>77<br>59<br>M10<br>3/8-16 UNC-2B<br>10<br>24.5|
|3|BKN/75 + GKN/75<br>73.3<br>75.4<br>92<br>74<br>M12<br>1/2-13 UNC-2B<br>10<br>30.0<br>BKN/90 + GKN/90<br>80.3<br>91.4<br>92<br>74<br>M12<br>1/2-13 UNC-2B<br>10<br>30.0|
- 1 Valid for fuse Types -GKN/-.
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 170K8564 (Size 1*), 170K8566 (Size 1), 170K8568 (Size 2), 170K8570 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-63
**4 — High speed fuses**
170M — Square Body size 1* to 3, flush-end contact
1000 Vac (IEC and UL), 50 to 1400 A
**==> picture [537 x 577] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated I²t (A²s) Watts Catalog no.<br>Fuse current Clearing at loss -BKN/- Type K indicator for -GKN/- Type K indicator for<br>size Rated voltage (amps) Pre-arcing rated voltage (W)† microswitch microswitch<br>50 135 815 20 170M3951 170M3921<br>63 215 1300 25 170M3952 170M3922<br>80 460 2750 30 170M3953 170M3923<br>100 860 5100 35 170M3954 170M3924<br>125 1450 8600 40 170M3955 170M3925<br>1* 1000 Vac (IEC) 160 2850 17,500 45 170M3956 170M3926<br>200 4950 29,500 50 170M3957 170M3927<br>250 9550 57,000 55 170M3958 170M3928<br>315 21,500 130,000 65 170M3959 170M3929<br>350 29,000 175,000 70 170M3960 170M3930<br>400 42,000 250,000 75 170M3961 170M3931<br>160 2200 13,500 40 170M4951 170M4921<br>200 4150 24,500 45 170M4952 170M4922<br>250 7750 46,000 52 170M4953 170M4923<br>315 16,500 98,500 60 170M4954 170M4924<br>350 21,500 130,000 65 170M4955 170M4925<br>1 1000 Vac IEC)<br>400 31,000 185,000 70 170M4956 170M4926<br>450 44,500 265,000 80 170M4957 170M4927<br>500 63,000 375,000 85 170M4958 170M4928<br>550 84,500 500,000 90 170M4959 170M4929<br>630 125,000 755,000 98 170M4960 170M4930<br>250 6750 40,000 65 170M5952 170M5922<br>315 13,500 81,500 75 170M5953 170M5923<br>350 16,500 99,000 80 170M5954 170M5924<br>400 26,000 155,000 85 170M5955 170M5925<br>450 35,500 210,000 90 170M5956 170M5926<br>2 1000 Vac (IEC/UL)<br>500 49,500 295,000 95 170M5957 170M5927<br>550 66,000 390,000 100 170M5958 170M5928<br>630 93,500 555,000 110 170M5959 170M5929<br>700 130,000 770,000 115 170M5960 170M5930<br>800 195,000 1,200,000 125 170M5961 170M5931<br>315 9200 54,500 90 170M8600 170M8500<br>350 13,000 77,500 95 170M8601 170M8501<br>400 19,000 115,000 105 170M8602 170M8502<br>450 27,000 160,000 107 170M8603 170M8503<br>500 37,500 225,000 110 170M8604 170M8504<br>550 52,000 310,000 115 170M8605 170M8505<br>1000 Vac (IEC/UL)<br>630 82,500 490,000 120 170M8606 170M8506<br>3<br>700 115,000 700,000 125 170M8607 170M8507<br>800 170,000 1,050,000 135 170M8608 170M8508<br>900 250,000 1,500,000 145 170M8609 170M8509<br>1000 340,000 2,050,000 150 170M8610 170M8510<br>1100 460,000 2,750,000 155 170M8611 170M8511<br>1000 Vac (IEC) 1250 575,000 3,400,000 175 170M8612 [1] 170M8512 [1]<br>900 Vac (IEC) 1400 795,000 4,200,000 185 170M8613 [1] 170M8513 [1]<br>**----- End of picture text -----**<br>
† Watts loss at rated current.
1 Overall length is 90mm, for all other fuses the overall length is 75mm.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K8564 (Size 1*), 170K8566 (Size 1), 170K8568 (Size 2), 170K8570 (Size 3)
Eaton.com/bussmannseries
4-64
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 1* to 3, flush-end contact
1250 Vac (IEC), 1300 Vac (UL), 50 to 1400 A
Square body flush-end contact high speed fuses, for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Catalog numbers come with Type K indicator for use with microswitches.
## Ratings
- Volts
- 1250 Vac (IEC)
- 1300 Vac (UL)
- 900 and 1000 Vdc (UL, see catalog number table for specific fuses)
- Amps 50-1400 A
- IR 100 kA RMS Sym.
Operating class aR
Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085[†]
- CSA Class 53787, File 1422-30[†]
## • CE
† Consult your Bussmann series product representative status.
Dimensions — mm
Type -BKN/- and -GKN/-
|Size|Type<br>A<br>B<br>D<br>E<br>F|F1(in)|Min G<br>HØ|
|---|---|---|---|
|1*<br>1|BKN + GKN/75<br>74<br>75<br>59<br>45<br>M8<br>BKN/80<br>80<br>81<br>59<br>45<br>M8<br>BKN + GKN/75<br>74<br>75<br>69<br>53<br>M8<br>BKN/80<br>80<br>81<br>69<br>53<br>M8|5/16-18 UNC-2B|5<br>17<br>5<br>17<br>8<br>20<br>8<br>20|
||BKN + GKN/75<br>74<br>75<br>77<br>61<br>M10||10<br>24|
|2|BKN/80<br>80<br>81<br>77<br>61<br>M10|3/8-16 UNC-2B|10<br>24|
||BKN + GKN/90<br>80<br>91<br>77<br>61<br>M10||10<br>24|
||BKN + GKN/75<br>74<br>76<br>92<br>76<br>M12||10<br>30|
|3|BKN/80<br>81<br>83<br>92<br>76<br>M12|1/2-13 UNC-2B|10<br>30|
||BKN + GKN/90<br>81<br>91<br>92<br>76<br>M12||10<br>30|
1 Valid for fuse Types -GKN/-.
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 170K6630 (Size 1*), 170K6632 (Size 1), 170K6634 (Size 2), 170K6636 (Size 3)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-65
**4 — High speed fuses**
170M — Square Body size 1* to 3, flush-end contact
1250 Vac (IEC), 1300 Vac (UL), 50 to 1400 A
**==> picture [537 x 539] intentionally omitted <==**
**----- Start of picture text -----**<br>
I²t (A²s) Catalog no.<br>Rated Clearing Clearing Watts -BKN/75 Type -BKN/80 Type -BKN/90 Type -GKN/75 Type -GKN/90 Type<br>Fuse current Pre- at 1000 at 1250 loss K indicator for K indicator for K indicator for K indicator for K indicator for<br>size Rated voltage (amps) arcing Vac Vac (W)† micro micro micro micro micro<br>50 135 815 1100 15 170M3388†† 170M3438 — 170M3488†† —<br>63 215 1300 1750 20 170M3389†† 170M3439 — 170M3489†† —<br>80 420 2500 3350 25 170M3390†† 170M3440 — 170M3490†† —<br>100 750 4450 5950 30 170M3391†† 170M3441 — 170M3491†† —<br>125 1450 9000 11,500 35 170M3392†† 170M3442 — 170M3492†† —<br>1250 Vac (IEC)<br>1* 160 2600 16,000 21,000 40 170M3393†† 170M3443 — 170M3493†† —<br>1300 Vac (UL) 200 5150 31,000 41,000 45 170M3394†† 170M3444 — 170M3494†† —<br>250 9200 54,500 73,000 55 170M3395†† 170M3445 — 170M3495†† —<br>315 18,500 115,000 150,000 60 170M3396†† 170M3446 — 170M3496†† —<br>350 27,000 165,000 220,000 65 170M3397†† 170M3447 — 170M3497†† —<br>400 53,000 265,000 335,000 70 — 170M3448 — — —<br>160 1900 11,500 15,500 45 170M4388†† 170M4438†† — 170M4488 —<br>200 3800 22,500 30,000 50 170M4389†† 170M4439†† — 170M4489 —<br>250 7750 46,000 61,500 60 170M4390†† 170M4440†† — 170M4490 —<br>315 15,000 90,000 120,000 65 170M4391†† 170M4441†† — 170M4491 —<br>1250 Vac (IEC) 350 20,000 125,000 165,000 70 170M4392†† 170M4442†† — 170M4492 —<br>1 1300 Vac (UL) 400 29,500 175,000 235,000 75 170M4393†† 170M4443†† — 170M4493 —<br>450 42,000 250,000 335,000 80 170M4394†† 170M4444†† — 170M4494 —<br>500 69,500 340,000 435,000 85 170M4395 [4] 170M4445 — 170M4495 [4] —<br>550 95,000 465,000 590,000 95 170M4396 [5] 170M4446 — 170M4496 [5] —<br>630 130,000 660,000 N/A 110 170M4397 [5] 170M4447 [4] — 170M4497 [5] —<br>250 6500 38,500 51,500 65 170M5388 170M5438 — 170M5588 —<br>280 9350 55,500 74,500 70 170M5389 170M5439 — 170M5589 —<br>315 13,000 77,500 105,000 75 170M5390 170M5440 — 170M5590 —<br>350 16,500 97,500 135,000 80 170M5391 170M5441 — 170M5591 —<br>400 23,000 140,000 180,000 85 170M5392 170M5442 — 170M5592 —<br>450 34,000 205,000 270,000 90 170M5393 170M5443 — 170M5593 —<br>1250 Vac (IEC)<br>2 500 48,000 285,000 380,000 95 170M5394 170M5444 170M5494 170M5594 170M5644<br>1300 Vac (UL) 550 62,000 370,000 495,000 100 170M5395 170M5445 170M5495 170M5595 170M5645<br>630 115,000 575,000 730,000 120 170M5396 [4] 170M5446 170M5496 170M5596 [4] 170M5646<br>700 160,000 795,000 1,050,000 125 170M5397 [5] 170M5447 [1] ††† 170M5497 170M5597 [5] 170M5647<br>800 245,000 1,200,000 1,550,000 130 170M5398 [5] 170M5448 [2] ††† 170M5498 170M5598 [5] 170M5648<br>900 360,000 1,750,000 N/A 135 — — 170M5499 [3] †† — 170M5649 [3] ††<br>1000 480,000 2,350,000 N/A 145 — — 170M5500 [3] †† — 170M5650 [3] ††<br>315 9500 58,000 77,500 85 170M6338†† 170M6538†† — 170M6588 —<br>350 13,500 81,500 110,000 90 170M6339†† 170M6539†† — 170M6589 —<br>400 19,500 120,000 160,000 95 170M6340†† 170M6540†† — 170M6590 —<br>450 31,000 185,000 245,000 100 170M6341†† 170M6541†† — 170M6591 —<br>500 39,000 235,000 310,000 105 170M6342†† 170M6542†† — 170M6592 —<br>550 55,000 325,000 435,000 110 170M6343†† 170M6543†† — 170M6593 —<br>1250 Vac (IEC) 630 83,500 495,000 665,000 115 170M6344†† 170M6544†† 170M6494†† 170M6594 170M6644<br>3<br>1300 Vac (UL) 700 115,000 705,000 940,000 120 170M6345 170M6545†† 170M6495†† 170M6595 170M6645††<br>800 205,000 995,000 1,300,000 125 170M6346 [4] 170M6546†† 170M6496††† 170M6596 [4] 170M6646†††<br>900 305,000 1,500,000 1,900,000 130 170M6347 [5] 170M6547 [1] †† 170M6497††† 170M6597 [5] 170M6647†††<br>1000 450,000 2,150,000 2,750,000 135 170M6348 [5] 170M6548 [1] †† 170M6498††† 170M6598 [5] 170M6648†††<br>1100 575,000 2,800,000 3,600,000 160 170M6349 [5] 170M6549 [2] †† 170M6499††† 170M6599 [5] 170M6649†††<br>1250 810,000 3,950,000 N/A 170 — — 170M6500 [3†] † — 170M6650 [4]<br>1400 1,250,000 6,000,000 N/A 175 — — 170M6501 [3†] † — 170M6651 [4]<br>**----- End of picture text -----**<br>
- Watts loss at rated current.
- †† DC voltage rated at 900 Vdc, UL Recognized, File E125085.
- ††† DC voltage rated at 1000 Vdc, UL Recognized, File E125085.
- 1 Rated voltage 1100 Vac (IEC), 1000 Vac (UL).
- 2 Rated voltage 1000 Vac (IEC and UL).
- 3 Rated voltage 1100 Vac (IEC and UL).
- 4 Rated voltage (IEC) 1100 Vac.
- 5 Rated voltage (IEC) 1000 Vac.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6630 (Size 1*), 170K6632 (Size 1), 170K6634 (Size 2), 170K6636 (Size 3)
Eaton.com/bussmannseries
4-66
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 4, flush-end contact
690 Vac (IEC), 700 Vac (UL), 1000 to 4000 A
Square body, flush-end contact, high speed fuses, for the protection of power rectifiers. Catalog numbers come with visual indicator or Type K indicator for use with microswitches.
## Ratings
- Volts
- 690 Vac (IEC)/700 Vac (UL) 1000-3500 A
- 600 Vac (IEC and UL, 4000 A)
- Amps 1000-4000 A
- IR 200 kA RMS Sym.
Operating class aR
Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085
- CE
|Fuse<br>size|Rated voltage|Rated<br>current<br>(amps)|I²t (A²s)<br>Pre-arcing<br>Clearing at<br>660 Vac|Watts loss<br>(W)†|Catalogno.<br>-B/65 visual<br>indicator<br>-BKN/65 Type<br>K indicator<br>-G/65 visual<br>indicator<br>-GKN/65 Type<br>K indicator|
|---|---|---|---|---|---|
|||1000|76,000<br>505,000|175|170M7058<br>170M7078<br>170M7098<br>170M7118|
|||1250|145,000<br>965,000|195|170M7059<br>170M7079<br>170M7099<br>170M7119|
|||1400|205,000<br>1,400,000|205|170M7060<br>170M7080<br>170M7100<br>170M7120|
||690 Vac (IEC)|1600|305,000<br>2,050,000|220|170M7061<br>170M7081<br>170M7101<br>170M7121|
|4|700 Vac (UL)|2000|600,000<br>3,950,000|245|170M7062<br>170M7082<br>170M7102<br>170M7122|
|||2500|1,200,000<br>7,800,000|275|170M7063<br>170M7083<br>170M7103<br>170M7123|
|||3000|2,000,000<br>13,500,000|305|170M7064<br>170M7084<br>170M7104<br>170M7124|
|||3500|3,250,000<br>22,000,000|325|170M7065<br>170M7085<br>170M7105<br>170M7125|
||600 Vac (IEC/UL)|4000|4,700,000<br>28,000,0001|355|170M7066<br>170M7086<br>170M7106<br>170M7126|
- Watts loss at rated current.
- 1 Clearing at 600 Vac.
For details on electrical characteristics, contact Application Engineering and ask for Data sheet no. 170K6328
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-67
**4 — High speed fuses**
## 170M — Square Body size 4, flush-end contact
690 Vac (IEC), 700 Vac (UL), 1000 to 4000 A
Dimensions — mm
Type -BKN/65, -GKN/65
**==> picture [236 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|PCD|Thread|
|-GKN/65|Ø 38.1|1/2-13 UNC|
|-BKN/65|Ø 33.0|M-10|
**----- End of picture text -----**<br>
Type -B/65, -G/65
**==> picture [236 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Type|PCDØ|Thread|
|-G/65|38.1|1/2-13 UNC|
|-B/65|33.0|M-10|
**----- End of picture text -----**<br>
For details on electrical characteristics, contact Application Engineering and ask for Data sheet no.170K6328
Eaton.com/bussmannseries
4-68
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 4, flush-end contact
1000 Vac (IEC), 1000 to 3000 A
Square body, flush-end contact, high speed fuses, for the protection of power rectifiers. Catalog numbers come with visual indicator or Type K indicator for use with microswitches.
## Ratings
- Volts 1000 Vac (IEC)
- Amps 1000-3000 A
- IR 200 kA RMS Sym.
## Operating class aR
## Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085
## • CE
|Fuse<br>size<br>Rated<br>voltage|Rated current<br>(amps)<br>1000<br>1100<br>1500|I²t (A²s)<br>Pre-arcing<br>Clearingat 1000 Vac<br>180,000<br>1,100,000<br>250,000<br>1,500,000<br>600,000<br>3,600,000|Watts<br>loss<br>(W)†<br>195<br>200<br>250|Catalogno.<br>-BKN/95 Type K indicator<br>-SBKN/90 Type K indicator<br>—<br>170M7542<br>—<br>170M7031<br>170M7636<br>170M7548|High speed fuses|
|---|---|---|---|---|---|
||1700|850,000<br>5,000,000|260|170M7639<br>170M7034||
|4<br>1000 Vac|1800<br>2000|1,000,000<br>5,950,000<br>1,450,000<br>8,600,000|265<br>270|170M7661<br>170M7053<br>170M7963<br>170M7544||
||2200|2,000,000<br>12,000,000|280|170M7090<br>170M7035||
||2500|3,000,000<br>18,000,000|295|170M7640<br>170M7036||
||2700|3,700,000<br>22,000,000|310|170M7658<br>170M7037||
||3000|4,700,000<br>28,000,000|380|170M7962<br>170M7156||
† Watts loss at rated current.
Dimensions — mm
Type 4BKN/95
Type 4SBKN/90
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K8520, 170K8520-R
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-69
**4 — High speed fuses**
## 170M — Square Body size 4, flush-end contact
## 1250 Vac (IEC), 800 to 2500 A
Square body, flush-end contact, high speed fuses, for the protection of power rectifiers. Catalog numbers come with visual indicator or Type K indicator for use with microswitches.
## Ratings
## • Volts
- 1250 Vac (IEC)
- 1200 Vdc (UL)
- Amps 800-2500 A
- IR
- 200 kA RMS Sym.
## Agency information
- 85 kA DC (L/R 2 ms)
- Designed and tested to IEC 60269 Part 4
## Operating class aR
- UL Recognized, JFHR2, E125085
- cURus JFHR2, E125085
- CE
||Rated|I²t (A²s)|Watts|Catalogno.|
|---|---|---|---|---|
|Fuse<br>size<br>Rated voltage|current<br>(amps)|Pre-arcing<br>Clearingat 1250 Vac|loss<br>(W)†|-BKN/105 Type K indicator<br>-SBKN/105 Type K indicator|
||800|145,000<br>905,000|195|170M7802<br>—|
||1000|275,000<br>1,750,000|220|170M7803<br>—|
||1200|495,000<br>3,100,000|240|170M7804<br>—|
||1400|800,000<br>5,000,000|250|170M7217<br>170M7512|
|4<br>1250 Vac (IEC)<br>1200 Vdc (UL)|1500<br>1700<br>1800|1,000,000<br>6,200,000<br>1,400,000<br>8,700,000<br>1,700,000<br>11,000,000|260<br>275<br>280|170M7597<br>170M7510<br>170M7676<br>170M7511<br>170M7532<br>170M7976|
||2000|2,300,000<br>14,500,000|305|170M7633<br>170M7513|
||2200|3,100,000<br>19,500,000|315|170M7592<br>170M7546|
||2400|4,000,000<br>25,000,000|330|170M7107<br>170M7516|
||2500|4,500,000<br>28,000,000|340|170M7595<br>170M7978|
- Watts loss at rated current.
## Dimensions — mm
Type 4BKN/105
Type 4SBKN/105
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6640 (1400-2400 A), 170K6642 (800-1200, 2500 A)
Eaton.com/bussmannseries
4-70
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 23, flush-end contact
## 660 Vac (IEC), 1000 to 4000 A
Square body, flush-end contact, high speed fuses, for the protection of power rectifiers. Catalog numbers available with Type K indicator for use with microswitches.
## Ratings
- Volts
- 660 Vac (IEC, 1000-3000 A)
- 600 Vac (IEC, 3500 A)
- 550 Vac (IEC, 4000 A)
- Amps 1000-4000 A
- IR 100 kA RMS Sym.
Operating class aR
## Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085
- CE
||||I²t (A²s)||Catalogno.|
|---|---|---|---|---|---|
|Fuse<br>size|Rated voltage|Rated<br>current<br>(amps)|Pre-arcing<br>Clearing at<br>660 Vac|Watts<br>loss<br>(W)†|-BU/55<br>-BKE/55<br>Type K<br>indicator<br>-BKN/55<br>Type K<br>indicator<br>-GU/55<br>-GKE/55<br>Type K<br>indicator<br>-GKN/55<br>Type K<br>indicator|
|||1000|79,000<br>530,000|170|170M6858<br>170M6898<br>170M6878<br>170M6918<br>170M6958<br>170M6938|
|||1100|95,000<br>635,000|185|170M6859<br>170M6899<br>170M6879<br>170M6919<br>170M6959<br>170M6939|
|||1250|155,000<br>1,050,000|190|170M6860<br>170M6900<br>170M6880<br>170M6920<br>170M6960<br>170M6940|
|||1400|200,000<br>1,350,000|210|170M6861<br>170M6901<br>170M6881<br>170M6921<br>170M6961<br>170M6941|
|||1500|240,000<br>1,650,000|215|170M6862<br>170M6902<br>170M6882<br>170M6922<br>170M6962<br>170M6942|
||660 Vac (IEC)|1600|315,000<br>2,150,000|220|170M6863<br>170M6903<br>170M6883<br>170M6923<br>170M6963<br>170M6943|
|23||1800|450,000<br>3,050,000|230|170M6864<br>170M6904<br>170M6884<br>170M6924<br>170M6964<br>170M6944|
|||2000|625,000<br>4,200,000|240|170M6865<br>170M6905<br>170M6885<br>170M6925<br>170M6965<br>170M6945|
|||2200|805,000<br>5,400,000|255|170M6866<br>170M6906<br>170M6886<br>170M6926<br>170M6966<br>170M6946|
|||2500|1,250,000<br>8,350,000|265|170M6867<br>170M6907<br>170M6887<br>170M6927<br>170M6967<br>170M6947|
|||3000|2,250,000<br>15,500,000|285|170M6868<br>170M6908<br>170M6888<br>170M6928<br>170M6968<br>170M6948|
||600 Vac (IEC)|3500|3,450,000<br>21,000,0001|315|170M6869<br>170M6909<br>170M6889<br>170M6929<br>170M6969<br>170M6949|
||550 Vac (IEC)|4000|5,000,000<br>27,500,0002|340|170M6870<br>170M6910<br>170M6890<br>170M6930<br>170M6970<br>170M6950|
- Watts loss at rated current.
- 1 Clearing at 600 Vac.
- 2 Clearing at 550 Vac.
When using these fuses, please consult our application engineers.
For details on electrical characteristics, contact Application Engineering and ask for Data sheet no. 170K6326
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-71
**4 — High speed fuses**
170M — Square Body size 23, flush-end contact
660 Vac (IEC), 1000 to 4000 A
Dimensions — mm
Type -BU/55, -BKE/55, -BKN/55
Type -GU/55, -GKE/55, -GKN/55
When using these fuses, please consult our application engineers.
For details on electrical characteristics, contact Application Engineering and ask for Data sheet no.170K6326
Eaton.com/bussmannseries
4-72
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 23, flush-end contact
## 1250 Vac (IEC), 630 to 2800 A
Square body, flush-end contact, high speed fuses, for the protection of power rectifiers. Catalog numbers available with visual indicator or Type K indicator for use with microswitches.
## Ratings
- Volts
- 1250 Vac (IEC 630 to 2200 A)
- 1100 Vac (IEC 2500 and 2800 A)
- 900 Vdc (UL, see catalog number table for specific fuses)
- Amps 630-2800 A
- IR 125 kA RMS Sym.
## Operating class aR
## Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized
- CE
||||I²t (A²s)||Catalogno.|
|---|---|---|---|---|---|
|Fuse<br>size|Rated voltage|Rated<br>current<br>(amps)|Pre-arcing<br>Clearing at<br>1250 Vac|Watts<br>loss<br>(W)†|-BU/75<br>visual<br>indicator<br>-BKE/75 Type<br>K indicator<br>-BKN/75<br>Type K<br>indicator<br>-BU/80<br>visual<br>indicator<br>-BKE/80<br>Type K<br>indicator<br>-BKN/80<br>Type K<br>indicator|
|||630|38,000<br>310,000|170|170M6775<br>170M6795<br>170M6785<br>—<br>—<br>—|
|||700|54,000<br>440,000|180|170M6776<br>170M6796<br>170M6786<br>—<br>—<br>—|
|||800|78,000<br>640,000|190|170M6777<br>170M6797<br>170M6787<br>—<br>—<br>—|
|||900|120,000<br>980,000|200|170M6805<br>170M6807<br>170M6806<br>—<br>—<br>—|
|||1000|155,000<br>1,250,000|210|170M6778<br>170M6798<br>170M6788<br>—<br>—<br>—|
|23|1250 Vac (IEC)|1100<br>1250<br>1400|220,000<br>1,750,000<br>330,000<br>2,700,000<br>460,000<br>3,800,000|220<br>230<br>240|170M6779<br>170M6799<br>170M6789<br>—<br>—<br>—<br>170M6780<br>170M6800<br>170M6790<br>—<br>—<br>—<br>170M6781<br>170M6801<br>170M6791<br>—<br>—<br>—|
|||1600|820,000<br>5,200,000|250|170M6782<br>170M6802<br>170M6792<br>—<br>—<br>—|
|||1800|1,200,000<br>7,600,000|260|170M6783††<br>170M6803††<br>170M6793††<br>—<br>—<br>—|
|||2000|1,800,000<br>11,000,000|270|—<br>—<br>—<br>170M6784<br>170M6804<br>170M6794|
|||2200|2,300,000<br>14,500,000|280|—<br>—<br>—<br>170M6815<br>170M6833<br>170M6827|
||1100 Vac (IEC)|2500<br>2800|3,200,000<br>16,000,0001<br>5,000,000<br>24,000,0001|290<br>300|—<br>—<br>—<br>170M6816<br>170M6834<br>170M6828<br>—<br>—<br>—<br>170M6817<br>170M6835<br>170M6829|
- Watts loss at rated current.
- †† DC voltage rated at 900 Vdc, UL Recognized, File E125085.
- 1 Clearing at 1000 V.
When using these fuses, please consult our application engineers.
## Dimensions — mm
For details on electrical characteristics, contact Application Engineering and ask for Data sheet no.170K6638
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-73
**4 — High speed fuses**
## 170M — Square Body size 24, flush-end contact
690 Vac (IEC), 2000 to 7500 A
Square body, flush-end contact, high speed fuses, for the protection of power rectifiers. Catalog numbers available with Type K indicator for use with microswitches.
## Ratings
- Volts
- 690 Vac (IEC 2000 to 7000 A)
- 500 Vac (IEC 7500 A)
- Amps 2000-7500 A
- IR 200 kA RMS Sym.
Operating class aR
## Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085
## • CE
|Fuse<br>size|Rated voltage|Rated<br>current<br>(amps)|I²t (A²s)<br>Pre-arcing<br>Clearing at<br>660 Vac|Watts loss<br>(W)†|-BU/60 without<br>indicator|Catalogno.<br>-BKN/60 Type<br>K indicator<br>-GU/60 without<br>indicator|Catalogno.<br>-BKN/60 Type<br>K indicator<br>-GU/60 without<br>indicator|-GKN/60 Type<br>K indicator|
|---|---|---|---|---|---|---|---|---|
|||2000|340,000<br>2,300,000|340|170M7138|170M7158|170M7198|170M7218|
|||2500|650,000<br>4,350,000|390|170M7139|170M7159|170M7199|170M7219|
|||3000|1,100,000<br>7,300,000|430|170M7140|170M7160|170M7200|170M7220|
|||3500|1,800,000<br>12,000,000|460|170M7141|170M7161|170M7201|170M7221|
|||4000|2,700,000<br>18,000,000|490|170M7142|170M7162|170M7202|170M7222|
|24|690 Vac (IEC)|4500<br>5000|3,800,000<br>25,500,000<br>5,450,000<br>36,500,000|520<br>540|170M7143<br>170M7144|170M7163<br>170M7164|170M7203<br>170M7204|170M7223<br>170M7224|
|||5500|7,400,000<br>49,500,000|560|170M7145|170M7165|170M7205|170M7225|
|||6000|9,600,000<br>64,000,000|580|170M7146|170M7166|170M7206|170M7226|
|||6500|12,500,000<br>83,000,000|600|170M7147|170M7167|170M7207|170M7227|
|||7000|15,000,000<br>100,000,000|630|170M7148|170M7168|170M7208|170M7228|
||500 Vac (IEC)|7500|18,500,000<br>93,000,0001|660|170M7149|170M7169|170M7209|170M7229|
- Watts loss at rated current.
1 Clearing at 500 Vac.
When using these fuses, please consult our application engineers.
Dimensions — mm
|Size|Type<br>A|
|---|---|
|24|BKN<br>2x3 M12<br>GKN<br>2x3 1/2-13 UNC-2B|
For details on electrical characteristics, contact Application Engineering and ask for Data sheet no.170K6332
Eaton.com/bussmannseries
4-74
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — Square Body size 24, flush-end contact
1000 Vac (IEC), 2000 to 5000 A
Square body, flush-end contact, high speed fuses, for the protection of power rectifiers. Catalog numbers come with Type K indicator for use with microswitches.
## Ratings
- Volts 1000 Vac (IEC)
- Amps 2000-5000 A
- IR 166 kA RMS Sym.
Operating class aR
Agency information
- Designed and tested to IEC 60269 Part 4
- UL Recognized, JFHR2, E125085
- CE
|Fuse<br>size<br>Rated voltage|Rated current (amps)|I²t (A²s)<br>Pre-arcing<br>Clearingat 1000 Vac|Watts loss (W)†<br>Catalog no.<br>-BKN/85 Type K indicator|
|---|---|---|---|
||2000|900,000<br>5,350,000|345<br>170M7608|
||3000|2,950,000<br>17,500,000|430<br>170M7680|
||3200|3,300,000<br>20,000,000|440<br>170M7567|
|24<br>1000 Vac (IEC)|3500<br>4000|4,500,000<br>27,000,000<br>6,800,000<br>40,000,000|450<br>170M7568<br>475<br>170M7569|
||4200|8,000,000<br>47,500,000|485<br>170M7498|
||4500|10,000,000<br>59,000,000|495<br>170M7488|
||5000|14,000,000<br>82,500,000|540<br>170M7622|
- Watts loss at rated current.
When using these fuses, please consult our application engineers.
Dimensions — mm
The normal position of the indicator is as shown position "N", position "E" on request only.
For details on electrical characteristics, contact Application Engineering and ask for Data sheet no.170K8514
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-75
## **4 — High speed fuses**
## Square Body fuse accessories
Fixed center fuse blocks for DIN 43653 fuses
Fuse blocks for use with DIN 43653 square body fuses with center distances of 80 and 110mm. Available for sizes 000, 00, 1*, 1, 2 and 3.
## Sizes 000 to 00
|Catalogno.|Max rated<br>voltage<br>Max fuse<br>amprating<br>Center<br>distance<br>(mm)<br>Fuse sizes|
|---|---|
|170H1007|1000<br>400<br>80<br>00, 000|
|170H1013|690<br>200<br>80<br>0000, 000|
Dimensions — mm
**==> picture [33 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
170H1007<br>**----- End of picture text -----**<br>
**==> picture [33 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
170H1013<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
4-76
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## Square Body fuse accessories
Fixed center fuse blocks for DIN 43653 fuses
## Sizes 1* to 3
||Catalogno.<br>Max rated<br>voltage<br>Max fuse amp<br>rating<br>Center distance<br>(mm)|
|---|---|
|170H3003<br>1000<br>630<br>80<br>170H3004†<br>1000<br>1250<br>80<br>~~eee~~||
||170H3005<br>1400<br>630<br>110|
||170H3006†<br>1400<br>1250<br>110|
† Fuses with ratings higher than 1250 A can be used with 170H3004 or 170H3006 if the maximum load current is derated according to this table.
|Fuse am|Fuse amprating<br>Max. ampload in fuse block|
|---|---|
|1400|1325|
|1500|1400|
|1600|1500|
|1800|1650|
|2000|1800|
## Dimensions — mm
**==> picture [305 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
170H3003 170H3005<br>**----- End of picture text -----**<br>
**==> picture [305 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
170H3004 170H3006<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-77
**4 — High speed fuses**
## Square Body fuse accessories
## Indicators
High speed square body fuses are available with the following indicators.
## Visual indicator
The indicator situated in one end plate is clearly visible as soon as the fuse has operated. The minimum rated voltage for operating the indicator is 20 V.
## Type T indicator
The indicator is situated on one cover plate with a cover plate tag to accommodate an auxiliary switch. The minimum rated voltage for operating the indicator is 20 V. A special low rated voltage indicator (1.5 V) is available on request.
## Type K indicator
The indicator is situated on the fuse body. It is covered by an adapter for snap-on mounting of a microswitch. The rated operating voltage of the indicator is 1.5 V. As a matter of safety, the factory mounted adapter must not be removed from the fuse.
## Microswitches
High speed square body fuses with either Type T or K indicators can be equipped with a microswitch for remote signaling of fuse operation. All microswitches have one normally open (NO) and one normally closed (NC) contact.
## Ratings
- Volts 250 Vac
- Amps 5 A
## Catalog numbers
||DIN 43653<br>DIN 43620<br>French style<br>Flush-end<br>US style|Quick|
|---|---|---|
|Fuse<br>size|Type T<br>Type K<br>aR<br>gR and dual<br>indication<br>Type T<br>Type K<br>Type T<br>Type K<br>Type K|connect<br>terminal<br>size (mm)|
|000|170H0236<br>—<br>170H0236<br>170H0236<br>—<br>—<br>—<br>—<br>—<br>170H0238<br>—<br>170H0238<br>170H0238<br>—<br>—<br>—<br>—<br>—|6.3x0.8<br>2.8x0.5|
|00|170H0235<br>—<br>170H0236<br>170H0236<br>—<br>—<br>170H0235<br>—<br>—<br>170H0237<br>—<br>170H0238<br>170H0238<br>—<br>—<br>170H0237<br>—<br>—|6.3x0.8<br>2.8x0.5|
|1*|170H0235<br>170H0069<br>170H0235<br>—<br>170H0236<br>170H0069<br>—<br>170H0069<br>170H0069<br>170H0237<br>—<br>170H0237<br>—<br>170H0238<br>—<br>—<br>—<br>—|6.3x0.8<br>2.8x0.5|
|1|170H0235<br>170H0069<br>170H02351<br>170H0236<br>170H0236<br>170H0069<br>—<br>170H0069<br>170H0069<br>170H0237<br>—<br>170H02371<br>170H0238<br>170H0238<br>—<br>—<br>—<br>—|6.3x0.8<br>2.8x0.5|
|2|170H0235<br>170H0069<br>170H0235<br>170H0236<br>170H0236<br>170H0069<br>—<br>170H0069<br>170H0069<br>170H0237<br>—<br>170H0237<br>170H0238<br>170H0238<br>—<br>—<br>—<br>—|6.3x0.8<br>2.8x0.5|
|3|170H0235<br>170H0069<br>170H0236<br>170H0236<br>170H0236<br>170H0069<br>—<br>170H0069<br>170H0069<br>170H0237<br>—<br>170H0238<br>170H0238<br>170H0238<br>—<br>—<br>—<br>—|6.3x0.8<br>2.8x0.5|
|4|—<br>—<br>—<br>—<br>—<br>—<br>—<br>170H0069<br>—||
|23|—<br>—<br>—<br>—<br>—<br>—<br>—<br>170H0069<br>—|6.3x0.8|
|24|—<br>—<br>—<br>—<br>—<br>—<br>—<br>170H0069<br>—||
1 DIN2* (55x55), if DIN2 then use microswitch 170H0236, 170H0238.
For special microswitches, double microswitches, microswitches with DC ratings, lower/higher signal levels and for insulation voltages please contact Eaton's Bussmann Division: bulehighspeedtechnical@eaton.com.
Eaton.com/bussmannseries
4-78
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**High speed fuses — 4**
## 170M — IGBT size 000 and 230
750 Vdc (IEC), 800 Vdc (UL), 25 to 630 A
Bolted tag high speed fuses for the protection of IGBT modules, optimized for use in IGBT inverter circuits with DC fuse voltage ratings up to 750 Vdc. Low inductance ≤ 15nH.
## Ratings
- Volts
- 750 Vdc tested at 863 Vdc according to IEC 60269-4
- 800 Vdc tested at 800 Vdc according to UL 248-1
- Amps 25-630 A
- IR 50 kA DC (1ms tc) at 800 Vdc
## Operating class aR
## Agency information
- UL DC Recognized, 800 Vdc L/R 1 ms max
|Fuse size|Rated voltage|Rated current (amps)|I²t (A²s)<br>Pre-arcing<br>Clearingat 690 Vac|Watts loss (W)†|Catalogno.<br>-FU/70<br>-FN/70|Catalogno.<br>-FU/70<br>-FN/70|
|---|---|---|---|---|---|---|
|||25|25<br>135|12|170M1750|170M1730|
|||32|45<br>240|13|170M1751|170M1731|
|||40|75<br>395|14|170M1752|170M1732|
|||50|135<br>695|16|170M1753|170M1733|
|||63|260<br>1350|17|170M1754|170M1734|
|||80|460<br>2350|20|170M1755|170M1735|
|000||100|795<br>4000|25|170M1756|170M1736|
|||125|1300<br>6800|29|170M1757|170M1737|
|||160|2550<br>13500|34|170M1758|170M1738|
|||200|4350<br>22000|40|170M1759|170M1739|
|||250|7400<br>37500|48|170M1760|170M1740|
||750 Vdc (IEC)<br>800 Vdc (UL)|315<br>350<br>100|12,500<br>65000<br>17,000<br>88000<br>380<br>1950|60<br>65<br>35|170M1761<br>170M1762<br>170M1770|170M1741<br>170M1742<br>170M1785|
|||125|645<br>3300|42|170M1771|170M1786|
|||160|1350<br>7000|47|170M1772|170M1787|
|||200|2550<br>13500|54|170M1773|170M1788|
|||250|4950<br>25000|62|170M1774|170M1789|
|230||315<br>350|9350<br>47500<br>12,000<br>61000|72<br>78|170M1775<br>170M1776|170M1790<br>170M1791|
|||400|18,500<br>94500|80|170M1777|170M1792|
|||450|27,000<br>140000|85|170M1778|170M1793|
|||500|37,500<br>190000|90|170M1779|170M1794|
|||550|48,500<br>245000|95|170M1780|170M1795|
|||630|69,500<br>355000|105|170M1781|170M1796|
- Watts loss at rated current.
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6422 (Size 000), 170K6426 (Size 230)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-79
## **4 — High speed fuses**
## 170M — IGBT size 000 and 230
750 Vdc (IEC), 800 Vdc (UL), 25 to 630 A
Dimensions — mm
Size 000
Size 230
For details on electrical characteristics, contact Application Engineering and ask for data sheets: 170K6422 (Size 000), 170K6426 (Size 230) 4-80 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018 Eaton.com/bussmannseries
Eaton.com/bussmannseries
4-80
**High speed fuses — 4**
## 170M — IGBT size 000 and 230
1000 Vdc (IEC and UL), 25 to 500 A
Bolted tag high speed fuses for the protection of IGBT modules, optimized for use in IGBT inverter circuits with DC fuse voltage ratings up to 1000 Vdc. Low inductance ≤ 20nH.
Ratings
- Volts
- 1000 Vdc tested at 1150 Vdc according to IEC 60269-4
- 1000 Vdc tested at 1000 Vdc according to UL 248-1
- Amps 25-500 A
- IR 50 kA DC (1ms tc)
Operating class aR
Agency information
- UL DC Recognized, 1000 Vdc L/R 1ms max
|Fuse<br>size|Rated voltage|Rated current (amps)|I²t (A²s)<br>Pre-arcing<br>Clearingat 1000 Vac|Watts loss (W)†|Catalogno.<br>-FU/90<br>-FN/90|Catalogno.<br>-FU/90<br>-FN/90|
|---|---|---|---|---|---|---|
|||25|19<br>95|14|170M1802|170M1842|
|||32|34<br>170|17|170M1803|170M1843|
|||40|61<br>300|20|170M1804|170M1844|
|||50|135<br>675|21|170M1805|170M1845|
|||63|245<br>1200|22|170M1806|170M1846|
|000||80<br>100|505<br>2500<br>1050<br>5150|27<br>32|170M1807<br>170M1808|170M1847<br>170M1848|
|||125|1900<br>9500|34|170M1809|170M1849|
|||160|4050<br>20,000|37|170M1810|170M1850|
|||200|8500<br>42,000|43|170M1811|170M1851|
||1000 Vdc (IEC/UL)|225<br>250|12,000<br>59,000<br>16,000<br>79,500|45<br>48|170M1812<br>170M1813|170M1852<br>170M1853|
|||100|600<br>3050|38|170M1824|170M1860|
|||125|1200<br>6050|42|170M1825|170M1861|
|||160|2550<br>13,000|48|170M1826|170M1862|
|||200|4650<br>23,000|55|170M1827|170M1863|
|230||250<br>315|9300<br>45,500<br>18,500<br>91,500|62<br>68|170M1828<br>170M1829|170M1864<br>170M1865|
|||350|24,500<br>125,000|75|170M1830|170M1866|
|||400|37,500<br>185,000|80|170M1831|170M1867|
|||450|52,000<br>260,000|85|170M1832|170M1868|
|||500|69,500<br>340,000|90|170M1833|170M1869|
- Watts loss at rated current.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
4-81
## **4 — High speed fuses**
## 170M — size 000 and 230
1000 Vdc (IEC and UL), 25 to 500 A
Dimensions — mm
Size 000
Size 230
For details on electrical characteristics, contact Application Engineering and ask for data sheets:170K6680 (Size 000), 170K6682 (Size 230) 4-82 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018 Eaton.com/bussmannseries
Eaton.com/bussmannseries
4-82
**IEC and British Standard fuses — 5**
## Contents
Bussmann series IEC **cylindrical fuses**
|Description|Section<br>page||||
|---|---|---|---|---|
|Fuses|||||
|CSA Type P and D fuses (CDN, CDS and PON)<br>HRC Form II Class C fuses (CGL)|2<br>3||||
|HRCI industrial ceramic body fuses|||||
|HRCI-CA (CIF21)<br>HRCI-CB (CIF06)|4||||
|HRCI-Misc. Type K (CIH, CIK and CIL)|5||||
|HRC Form II current-limiting fuses (H07C, K07C, L14C,<br>M14C, L09C, M09C, P09C, P11C, R11C)|6||||
|BS88 Part 1 fuses|||||
|SSD, NSD, ESD<br>STD, NITD, AAO, BAO, OSD, CEO, DEO|7||||
|BS88|||||
|AC, AD, BC, BD, CD, DD, ED, EFS<br>EF, FF, FG, GF, GG, GH|8||||
|DIN Type D Diazed (D16, D27, D33, D125)<br>9<br>DIN Type N Neozed (NZ01, NZ02)<br>~~ee~~|||||
|NH HRC fuses (NHG)|10-11||||
|JKS-700 fast-acting, current limiting UL Recognized and CSA<br>Component Acceptance 700 Vac fuses up to 60 amps<br>11<br>NH fuse blocks and accessories (SD, TD)<br>12<br>~~a~~|||||
|Fuses continued<br>IEC 60269 industrial fuses with and without indicator/striker<br>Class gG ferrule (C10G, C14G, C22G)<br>Class aM ferrule (C10M, C14M, C22M)<br>HRC fuse holders|13<br>14||IEC and British|Standard fuses|
|CAMaster|||||
|SAFEloc<br>Red Spot|15||||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
5-1
**5 — IEC and British Standard fuses** ~~7~~
CDN, CDS and PON CSA Type P and D fuses
Dimensions — in (mm) Pp ~~A B~~ Up to 60 A
CSA time-delay Type D and P fuses.
## Ratings
- Volts
- 250 Vac (CDN and PON)
|Up to 60 A|Up to 60 A|Up to 60 A|Up to 60 A|Up to 60 A|Up to 60 A||
|---|---|---|---|---|---|---|
|B<br>F<br>A<br>~~D~~<br>C<br>70 to 600 A<br>~~FL~~]<br>fT<br>Er~~g~~||||||E|
|Amps<br>A<br>B<br>C<br>D<br>E<br>F<br>CDN/PON 250 Vac<br>Upto 30<br>2.0(51)<br>0.6(14)<br>—<br>—<br>—<br>—<br>~~__E~~|||||||
|35-60<br>3.0(76)|0.8(21)<br>—|—||—||—|
|70-100<br>5.9(149)|—<br>1.0(25)|—||0.1(3)||0.8(19)|
|110-200<br>7.3(185)|—<br>1.4(35)|4.1(105)||0.2(5)||1.1(29)|
|225-400<br>8.6(219)|—<br>1.9(48)|4.6(118)||0.3(6)||1.6(41)|
|450-600<br>10.4(264)<br>CDS 600 Vac|—<br>2.3(57)|5.2(132)||0.3(6)||2(51)|
|Upto 30<br>5.0(127)|0.8(21)<br>—|—||—||—|
|35-60<br>5.5(140)<br>70-100<br>7.9(200)<br>110-200<br>9.6(245)<br>225-400<br>11.6(295)|1.1(27)<br>—<br>—<br>1.0(25)<br>—<br>1.4(35)<br>—<br>1.9(48)|—<br>—<br>6.1(116)<br>7.1(118)||—<br>0.1(3)<br>0.2(5)<br>0.3(6)||—<br>0.8(19)<br>1.1(29)<br>1.6(41)|
|450-600<br>13.4(340)|—<br>2.3(57)|8.2(208)||0.3(6)||2(51)|
- 600 Vac (CDS)
- Amps 10-600 A
- IR 10 kA minimum
## Agency information
- CSA Certified, Class 1421-01, File 53787, CE
## Features
- Economical fuse in a variety of ratings for applications not requiring time-delay
## Typical applications
- Lighting, heating and other circuits not subject to temporary surges and where available short-circuit current are relatively low
|Typical applications<br>• Lighting, heating and other circuits not subject to temporary<br>surges and where available short-circuit current are relatively low||()<br>225-400<br>8.6(219)<br>450-600<br>10.4(264)<br>CDS 600 Vac<br>Upto 30<br>5.0(127)|()<br>()<br>—<br>1.9(48)<br>4.6(118)<br>—<br>2.3(57)<br>5.2(132)<br>0.8(21)<br>—<br>—|()<br>()<br>—<br>1.9(48)<br>4.6(118)<br>—<br>2.3(57)<br>5.2(132)<br>0.8(21)<br>—<br>—|()<br>()<br>0.3(6)<br>1.6(41)<br>0.3(6)<br>2(51)<br>—<br>—|
|---|---|---|---|---|---|
|Catalog no.*<br>Catalog symbol<br>Volts<br>Available amp ratings<br>Time-Delay CSA Type "D" fuses<br>~~—————~~||35-60<br>5.5(140)<br>70-100<br>7.9(200)<br>110-200<br>9.6(245)<br>225-400<br>11.6(295)|1.1(27)<br>—<br>—<br>—<br>1.0(25)<br>—<br>—<br>1.4(35)<br>6.1(116)<br>—<br>1.9(48)<br>7.1(118)||—<br>—<br>0.1(3)<br>0.8(19)<br>0.2(5)<br>1.1(29)<br>0.3(6)<br>1.6(41)|
|CDN**<br>250 Vac<br>10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60,<br>70, 80, 90, 100, 110, 125, 150, 175, 200,<br>225, 250, 300, 350, 400, 450, 500, 600<br>CDS†<br>600 Vac<br>10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60,<br>70, 80, 90, 100, 110, 125, 150,175, 200,<br>225, 250, 300, 350, 400, 450, 500, 600<br>One-time CSA Type "P" fuses<br>PON<br>250 Vac<br>15, 20, 25, 30, 35, 40, 45, 50, 60<br>450-600<br>13.4(340)<br>—<br>2.3(57)<br>8.2(208)<br>0.3(6)<br>2(51)<br>Recommended fuse blocks<br>Catalog no.*<br>Volts<br>Fuse amps<br>250<br>600<br>Up to 30<br>HM25030-(poles)<br>HM60030-(poles)<br>~~—————ts—s~~||||||
|* To order, specify catalog symbol and amp rating, e.g., CDN30, CDS110 or||35-60|HM25060-(poles)||HM60060-(poles)|
|PON40.||70-100|HM25100-(poles)||HM60100-(poles)|
|** Below 10 amps, use FRN-R.<br>† Below 10 amps, use FRS-R.||110-200|HM25200-(poles)||HM60200-(poles)|
|||225-400|HM25400-(poles)||HM60400-(poles)|
|||450-600|HM25600-(poles)||HM60600-(poles)|
- To order, specify 1, 2 or 3 poles, e.g., HM25030-2_. See data sheets 10289 (30-60 A) and 3192 (70-600 A) for available terminals.
Data sheet no. 4126
Eaton.com/bussmannseries
5-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**IEC and British Standard fuses — 5**
## i
## CGL HRC Form II Class C fuses
Dimensions — in (mm)
**==> picture [122 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.22 0.22 0.81<br>(5.56) (5.56) (20.64)<br>(50.8)2.0 0.34 (1.59)0.06<br>2.80 (8.73) 0.94<br>(71.04) (23.81)<br>3.31<br>(84.14)<br>CGL 1-30<br>0.22 0.22 0.81<br>(5.56) (5.56) (20.64)<br>2.0 0.06<br>(50.8) 0.50 (1.59)<br>2.80 (12.7) 1.06<br>(71.04) (26.92)<br>3.5<br>(88.9)<br>CGL 35-60<br>**----- End of picture text -----**<br>
Current-limiting HRCII-C fuses designed to withstand inrush currents on typical motor start-ups while offering high current limitation in the short-circuit region. See drawings for dimensions.
## Ratings
- Volts
- 600 Vac
- 250 Vdc (1-30 A)
- Amps 1-600 A
- IR
- 200 kA
- 40 kA DC
**==> picture [143 x 71] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.343 0.343 1.34<br>(8.71) (8.71) (34.04)<br>0.09<br>(60.72)(92.47)2.393.64 (19.05)0.75 (34.93)(2.29)1.375<br>4.31<br>(109.54)<br>CGL 70-100<br>**----- End of picture text -----**<br>
## Agency information
- CSA Certified, Class 1422,File 53787, CE
|Catalog no. (amps)||||(109.54)||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||CGL 70-100||||||||||
|CGL-1|CGL-25|CGL-80|CGL-225|||||||||||
|CGL-2|CGL-30|CGL-90|CGL-250|~~0~~.343<br>(8.71)|0.343<br>(8.71)|||||||||
|CGL-3|CGL-35|CGL-100|CGL-300|||||||||||
|||||||||||||||
|CGL-4|CGL-40|CGL-110|CGL-350|||||||||||
|CGL-6<br>CGL-10<br>CGL-15<br>CGL-20|CGL-45<br>CGL-50<br>CGL-60<br>CGL-70|CGL-125<br>CGL-150<br>CGL-175<br>CGL-200|CGL-400<br>CGL-450<br>CGL-500<br>CGL-600|CGL 110-200<br>3.00<br>(76.2)<br>4.30<br>(109.22)<br>5.31<br>(134.87)<br>~~=ar~~|~~=ar~~|~~=ar~~|0.75<br>(19.05)<br>~~=ar~~|||1.50<br>(38.1)<br>~~=ar~~|||~~0~~.125<br>(3.18)<br>~~=ar@~~|
**==> picture [225 x 207] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.19<br>(4.76)<br>0.38 1.0<br>(9.53) (25.4)<br>1.0<br>(25.4)<br>3.0 2.38<br>(76.2) (60.33)<br>5.25<br>(133.35)<br>8.19<br>=ar (207.96) @<br>CGL 225-400<br>0.41 1.0<br>(10.32) (25.4)<br>1.0<br>(25.4) 0.60<br>3.0 (15.24) 0.375<br>(76.2) (9.53)<br>FY (133.35)5.258.19 (76.2)3.00<br>(207.96)<br>CGL 450-600<br>**----- End of picture text -----**<br>
## Features
- Close sizing to loads allows using smaller and less costly switches
- Provides a higher degree of short-circuit protection
- Helps protect motors against burnout from overloads
## Typical applications
- For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads
|• For use in circuits subject to surge currents such as those caused<br>by motors, transformers and other inductive loads<br>Available Red Spot fuse holders<br>Fuse amps<br>Catalog symbol*<br>Up to 32<br>RS32_<br>35-60<br>RS63_<br>70-100<br>RS100_<br>110-200<br>RS200_<br>~~——~~<br>~~——~~|
|---|
|225-400<br>RS400_|
* See Red Spot data sheet no. 10083 for terminal options.
Data sheet no. 4125
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
5-3
**5 — IEC and British Standard fuses** ~~7~~
## CIF21 HRCI-CA industrial ceramic body fuses
The HRCI-CA bolt-on, ceramic body fuse provides both overload and short-circuit protection to HRCI requirements. Offset blades for bolt-on mounting CIF21 fuse fits the Bussmann series Red Spot fuse holder (data sheet 10083) and CAMaster fuse holder (data sheet number 4132).
## Ratings
- Volts
- 600 Vac
- 250 Vdc
- Amps 1-30 A
- IR 200 kA RMS Sym.
## Agency information
> • CSA, Class 1422-02, File 53787, CE
**==> picture [262 x 67] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Catalog no.|Amps|Catalog no.|Amps|
|ETE|
|1CIF21|1|15CIF21|15|
|3CIF21|3|20CIF21|20|
|6CIF21|6|25CIF21|25|
|10CIF21|10|30CIF21|30|
**----- End of picture text -----**<br>
## Features
- Close sizing to loads allows using smaller and less costly switches
- Provides a higher degree of short-circuit protection
- Helps protect motors against burnout from overloads
## Typical applications
- For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads
Recommended fuse holders
**==> picture [262 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|ee|Amps|Description|Catalog no.*|
|Up to 20|Red Spot|RS20_(terminal option)|
|Up to 30|CAMaster|CM20CF|
**----- End of picture text -----**<br>
## CIF06 HRCI-CB industrial ceramic body fuses
A miniature offset clip-in blade, ceramic body industrial fuse that provides both short-circuit and overload protection and the CIF06 fits the 30 A SAFEloc fuse holder (data sheet number 4133).
## Ratings
- Volts
- 600 Vac
- 250 Vdc
- Amps 1-30 A
- IR 200 kA RMS Sym.
## Agency information
> • CSA, Class 1422-02, File 53787 (3-30 A only), CE
**==> picture [263 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|eee|Catalog no.|Amps|Catalog no.|Amps|
|1CIF06|1|15CIF06|15|
|OOOO|
|3CIF06|EE|3|20CIF06|20|
|6CIF06|6|25CIF06|25|
|10CIF06|10|30CIF06|30|
**----- End of picture text -----**<br>
## Features
- Close sizing to loads allows using smaller and less costly switches
- Provides a higher degree of short-circuit protection
- Helps protect motors against burnout from overloads
## Typical applications
- For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads
## Recommended fuse holders
**==> picture [224 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Amps|Description|Catalog no.*|
|Up to 30|SAFEloc|C30(terminal option)|
**----- End of picture text -----**<br>
- See data sheet no. 4133 for SAFEloc details.
Dimensions — in (mm)
- See data sheet no. 10083 (Red Spot) and 4132 (CAMaster) for details.
Dimensions — in (mm)
**==> picture [192 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.15 (55)<br>1.44 (36)<br>——<br>0.54 (14)<br>Gell 0.19 (5) TWst 0.44 (11)<br>TL,<br>-—— 1.75 (45) 4 0.03 (1)<br>**----- End of picture text -----**<br>
**==> picture [199 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.38 (60)<br>1.44 (36)<br>a<br>0.54 (14) 0.5 (13)<br>(co—<br>0.03 (4)<br>fT r*<br>0.14 (4)<br>**----- End of picture text -----**<br>
Data sheet no. 4127
Data sheet no. 4128
Eaton.com/bussmannseries
5-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**IEC and British Standard fuses — 5**
## weeny
## CIH, CIK and CIL HRCI — Misc. Type K fuses
Misc. Type K HRCI bolt-on, ceramic body fuses provide both overload and short-circuit protection, featuring offset blades for bolt down mounting.
Ratings
- Volts 600 V
- Amps 1-100 A
- IR 200 kA@600 V
Agency information
> • CSA, Class 1422-02, File 53787, CE
**==> picture [264 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|||Catalog no. (amp)CIH, CIK, CIL|
|1CIH07|15CIH07|35CIK07|80CIL14|
|3CIH07|20CIH07|40CIK07|90CIL14|
|6CIH07|25CIH07|50CIK07|100CIL14|
|10CIH07|30CIH07|60CIK07|
**----- End of picture text -----**<br>
Dimensions — in (mm)
**==> picture [259 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|F|J|
|K|D|A|G|E|
|B|
|G|
|L|H|
|ae|C|
|The CIL14 has a rejection hole, not a slot as shown above.|
|Amps|A|B|C|D|E|F|G|H|J|K|L|
|Up to|2.25|0.94|3.38|0.38|0.04|2.88|0.21|0.31|1|0.10|2.38|
|30|(57)|(24)|(86)|(10)|(1)|(73)|(5)|(8)|(25)|(3)|(60)|
|2.28|1.06|3.56|0.5|0.05|2.88|0.21|0.41|1.09|0.13|2.38|
|35-60|
|(58)|(27)|(91)|(13)|(1)|(73)|(5)|(11)|(28)|(3)|(61)|
|80-100|2.75|1.44|4.38|0.75|0.09|3.69|0.34|0.41|1.5|—|2.91|
|(70)|(37)|(111)|(19)|(3)|(94)|(9)|(11)|(39)|(74)|
|Recommended fuse holders|
**----- End of picture text -----**<br>
**==> picture [184 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Amps|Red Spot*|CAMaster*|
|—|Up to 30|RS32_|CM30CF|
|35-60|RS63_|CM60CF|
|80-100|RS100_|—|
**----- End of picture text -----**<br>
* See data sheet no. 10083 (Red Spot) and 4132 (CAMaster) for details.
Data sheet no. 4130
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
5-5
**5 — IEC and British Standard fuses**
## HRC Form II current-limiting fuses
- HRC Form II bolt-on, ceramic body current-limiting fuses. Ratings • Volts pao
- • 600 Vac (or less) • 250 Vdc
- Amps 2-600 A
- IR 200 kA RMS Sym.
Agency information • CSA, Class 1422-02, File 53787, BS88:2, IEC 60269:2, CE (amps) catalog no. ~~[I~~ H07C offset blades 2H07C 6H07C 15H07C 25H07C ~~So~~ 4H07C 10H07C 20H07C 30H07C K07C offset blades 40K07C 60K07C 100K07CR ~~ae~~ 50K07C 80K07CR L14C offset blades 80L14C 100L14C M14C offset blades 125M14C* 150M14C* 200M14C* L09C center blades 80L09C* 100L09C* M09C center blades 125M09C 150M09C 200M09C P09C center blades 250P09C* 300P09C* 350P09C* 400P09C* P11C center blades 250P11C 300P11C 350P11C 400P11C R11C center blades 450R11C 500R11C 600R11C
* Not suitable for installation in Red Spot fuse holders.
## Typical applications
- Used to protect motor control circuits, together with contactors and overload protection relays to provide Type 2 coordination per IEC 60947-4.
## Dimensions — in (mm)
**==> picture [175 x 256] intentionally omitted <==**
**----- Start of picture text -----**<br>
F J<br>G A D E<br>Lp e a<br>B<br>= H 1 EL<br>C<br>H07C offset blades<br>‘ E R<br>5 F —: E D J T<br>A E<br>G<br>D<br>B<br>H<br>C<br>K07C, K07CR, L14C, M14C offset blades<br>C B<br>A<br>H<br>G<br>D<br>F E<br>L09C, M09C, P09C center blades aime:<br>K F K B<br>A<br>G D =<br>H E<br>C<br>e P11C, R11C center blades e e<br>**----- End of picture text -----**<br>
|Catalog<br>symbol/<br>style<br>A<br>B<br>H07C offset blades|C|D|E|F|G|H|J<br>K|CSA<br>category|
|---|---|---|---|---|---|---|---|---|
|2-30<br>1.38<br>(35)<br>0.56<br>(14)|3.38<br>(85)|0.38<br>(9)|0.06<br>(1)|2.88<br>(73)|0.22<br>(6)|0.31<br>(8)|0.56<br>(14)<br>—|HRCII-C|
|K07C offset blades<br>40-60<br>2.19<br>(56)<br>0.88<br>(22)<br>80-100<br>2.19<br>(56)<br>0.88<br>(22)|3.44<br>(87)<br>3.75<br>(95)|0.5<br>(13)<br>0.5<br>(13)|0.06<br>(1)<br>0.06<br>(1)|2.88<br>(73)<br>2.88<br>(73)|0.22<br>(6)<br>0.22<br>(6)|0.31<br>(8)<br>0.31<br>(8)|0.88<br>(22)<br>—<br>0.88<br>(22)<br>—|HRCII-C<br>HRCII-<br>MISC|
|L14C offset blades|||||||||
|80-100<br>2.38<br>(60)<br>0.88<br>(21)<br>M14C offset blades|4.38<br>(111)|0.56<br>(14)|0.13<br>(3)|3.69<br>(94)|0.34<br>(9)|0.44<br>(11)|1<br>(25)<br>—|HRCII-C|
|125-200<br>2.56<br>(65)<br>1.5<br>(38)|4.38<br>(111)|0.75<br>(19)|0.09<br>(2)|3.69<br>(94)|0.34<br>(9)|0.44<br>(11)|—<br>—|HRCII-<br>MISC|
|L09C center blades|||||||||
|80-100<br>2.38<br>(60)<br>0.88<br>(21)|5<br>(127)|0.56<br>(14)|0.13<br>(3)|4.38<br>(111)|0.34<br>(9)|0.44<br>(11)|—<br>—|HRCII-<br>MISC|
|M09C center blades<br>125-200<br>2.56<br>(65)<br>1.5<br>(38)<br>P09C center blades|5.38<br>(136)|0.75<br>(19)|0.13<br>(3)|4.38<br>(111)|0.34<br>(9)|0.56<br>(14)|—<br>—|HRCII-C|
|250-400<br>3.06<br>(178)<br>2.31<br>(59)|5.38<br>(136)|1<br>(25)|0.19<br>(5)|4.38<br>(111)|0.34<br>(9)|0.5<br>(13)|—<br>—|HRCII-<br>MISC|
|P11C center blades<br>250-400<br>3.06<br>(178)<br>2.31<br>(59)|8.25<br>(210)|1<br>(25)|0.19<br>(5)|5.25<br>(133)|0.41<br>(10)|0.63<br>(16)|—<br>1<br>(25)|HRCII-C|
|R11C center blades|||||||||
|450-600<br>3.19<br>(81)<br>2.88<br>(73)|8.25<br>(210)|1<br>(25)|0.25<br>(6)|5.25<br>(133)|0.41<br>(10)|0.63<br>(16)|—<br>1<br>(25)|HRCII-C|
Recommended fuse holders: Red Spot up to 400 amps (data sheet no.10083) and CAMaster up to 100 amps (data sheet no. 4132).
Data sheet no. 4131
Eaton.com/bussmannseries
5-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**IEC and British Standard fuses — 5** SSD, NSD, ESD BS88 Part 1 fuses STD, NITD, AAO, BAO, OSD, CEO, DEO BS88 Part 1 fuses The NSD and ESD are low voltage offset blade, ceramic body fuses complying with general purpose gG characteristics. The STD to DEO type ceramic body, offset bolt-on blade low voltage fuses complying with general purpose gG characteristics. Ratings Ratings • Volts 240-550 Vac • Amps • Volts 240-550 Vac • 2-63 A • Amps • 20M25 to 63M100 motor starter ratings • 2-200 A • IR • 20M25 to 200M315 motor starter ratings • 33 kA (SSD) • IR • 80 kA (NSD, ESD) • 33 kA (STD) • 80 kA (NITD, AAO, BAO, CEO, DEO, OSD)
## Agency information
Agency information • Meets the requirements of BS88 Part 1 and IEC 60269-1, CE • Meets the requirements of BS88 Part 1 and IEC 60269-1, CE
Catalog no.* Catalog Max BS88 Catalog no.* symbol Amps (class) Vac ref. Catalog Max BS88 SSD 2, 4, 6, 10, 16, 20, 25, 32 (gG) 240 E1 symbol Amps (class) Vac ref. 2, 4, 6, 10, 16, 20, 25, 32 (gG) 550 STD 2, 4, 6, 10, 16, 20, 25, 32 (gG) 240 — NSD[†] F1 20M25, 20M32, 20M36, 32M36, 32M40, 32M50, 32M63 (gM) 415 NITD[†] 2, 4, 6, 10, 16, 20, 25, 32 (gG)20M25, 20M32 (gM) 550 — 2, 4, 6, 10, 16, 20, 25, 32 (gG) 550 32M40, 32M50, 32M63 (gM) 415 ESD[†] 40, 50, 63 (gG) F2 415 2, 4, 6, 10, 16, 20, 25, 32, (gG) 550 63M80, 63M100 (gM) AAO[†] A2 32M40, 32M50, 32M63 (gM) 500 * To order, specify catalog symbol and amp rating, e.g., SSD20. † "M" indicates motor starter ratings. 40, 50, 63 (gG) BAO[†] 500 A3 63M80, 63M100 (gM) Recommended fuse holders 32, 40, 50, 63, 80, 100 (gG) 550 CEO[†] A4 Fuse symbol Catalog no. 100M125, 100M160, 100M200 (gM) 415 NSD 32NNSF 125, 160, 200 (gG) DEO[†] 415 — ESD 63ENSF 200M315 (gM) 80, 100 (gG) 500 OSD[†] — 100M125, 100M160 (gM) 415
* To order, specify basic catalog symbol and amp rating. E.g., BAO16. † "M" indicates motor starter ratings.
- Typical applications • The STD type are used in 240 V street lighting cut-outs • NITD to DEO types used for industrial and general purpose applications
|Data sheet no. 4105 (SSD), 4100 (NSD) and 4101 (ESD)|Data sheet no. 4105 (SSD), 4100 (NSD) and 4101 (ESD)|Data sheet no. 4105 (SSD), 4100 (NSD) and 4101 (ESD)|Data sheet no. 4105 (SSD), 4100 (NSD) and 4101 (ESD)|Recommended fuse blocks and holders<br>Fuse catalog symbol<br>Block/holder catalog no.*<br>NITD<br>CM32FC, RS20_<br>AAO<br>CM32F, RS32_<br>BAO<br>CM63F, RS63_<br>OSD<br>CM100F, RS100_<br>CEO<br>BH-0111<br>* See data sheet no. 4132 (CM_), 10083 (RS_) and 1200 (BH-_).<br>Data sheet no. 4105 (SSD), 4100 (NSD) and 4101 (ESD)<br>Data sheet no. 4123 (STD), 4106 (NITD), 4109 (AAO),<br>4112 (BAO), 4107 (OSD), 4115 (CEO) and 4117 (DEO)<br>5-7<br>BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018<br>Eaton.com/bussmannseries~~=~~|
|---|---|---|---|---|
**5 — IEC and British Standard fuses**
## AC, AD, BC, BD, CD, DD, ED, EFS BS88 fuses
Ceramic body, center blade two-hole bolt-on low voltage fuses that comply with general purpose gG characteristics and available up to 400 amps with two hole mount and up to 1250 amps with four hole mount.
## Ratings
- Volts
- 415/550 Vac
- 250 Vdc
- Amps
- 2-400 A
- 63M80 to 400M500 motor starter ratings
## EF, FF, FG, GF, GG, GH BS88 fuses
Ceramic body, center blade four-hole bolt-on low voltage fuses complying with general purpose gG characteristics and available up to 400 amps with two hole mount and up to 1250 amps with four hole mount.
Ratings (see catalog numbers table)
- Volts
- 415/690 Vac
- 250/400 Vdc
- Amps 355-1250 A
- IR see catalog numbers table
## Agency information
- IR see catalog numbers table
## Agency information
- Meets the requirements of BS88 Parts 1 and 2 and IEC 60269-1, CE
|Catalog no.*|Catalog no.*|IR ( kA)|IR ( kA)|Max volts|Max volts||
|---|---|---|---|---|---|---|
|Catalog<br>symbol<br>AC<br>AD<br>BC†<br>BD|Amps (class)<br>2, 4, 6, 10, 16, 20 (gG)<br>25, 32 (gG)<br>2, 4, 6, 10, 16, 20 (gG)<br>25, 32 (gG)<br>40, 50, 63 (gG)<br>63M80, 63M100 (gM)<br>40, 50, 63 (gG)<br>CD80, CD100 (gG)|AC<br>80<br>80<br>80<br>80|DC<br>40<br>40<br>40<br>40|AC<br>550<br>500<br>550<br>500<br>500<br>500<br>500|DC<br>250<br>250<br>250<br>250<br>—|BS88<br>ref.<br>—<br>—<br>—<br>—|
|CD†|100M125, 100M160,<br>100M200 (gM)|80|—|415|—|B1|
|DD†|125, 160, 200 (gG)|80|—|415|—|B2|
||200M250, 200M315 (gM)||||||
||250, 315, 355, 400 (gG)||||||
|ED†|315M400 (gM)|80|—|415|—|B3<br>B4|
||400M500 (gM)|||550|||
|EFS|125, 160, 200, 250, 315<br>(gG)|80|—|415|—|—|
- Meets the requirements of BS88 Parts 1 and 2 and IEC 60269-1, CE
|Catalog no.*|Catalog no.*|IR ( kA)|IR ( kA)|Max volts|Max volts||
|---|---|---|---|---|---|---|
|Catalog<br>symbol|Amps (class)|AC|DC|AC|DC|BS88<br>ref.|
|EF†|355, 400 (gG)|80|40|415|—|C1|
||400M500 (gM)|||550|||
|FF|450, 500, 560, 630 (gG)|80|40|550|400|C2|
|FG|450, 500, 560, 630 (gG)|80|40|550|400|—|
|GF|710, 800 (gG)|80|40|550|250|C3|
|GG|710, 800 (gG)|80|40|550|250|—|
||1000, 1250 (gG)||—||—||
|GH|710, 800, 1000, 1250|80|—|550|—|D1|
- To order, specify catalog symbol and amp rating, e.g., FG450.
- "M" indicates motor starter ratings.
* To order, specify catalog symbol and amp rating. E.g., BC40.
- "M" indicates motor starter ratings.
## Recommended fuse blocks
|Fuse catalog symbol|Fuse catalog symbol|Fuse catalog symbol<br>Modular block catalog no.*|Modular block catalog no.*|
|---|---|---|---|
||AC||BH-0111|
||AD||BH-____|
||BC||BH-0111|
||BD||BH-____|
||CD||BH-____|
||DD||BH-____|
||ED||BH-1131|
- See data sheet no. 1200 (BH-0_) and 1201 (BH-1_) for details.
Data sheets no. 4110 (AC), 4111 (AD), 4113 (BC), 4114 (BD), 4116 (CD), 4118 (DD), 4119 (ED) and 4121 (EFS)
Data sheet no. 4120 (EF), 4102 (FF), 4122 (FG), 4103 (GF), 4104 (GG) and 4108 (GH)
Eaton.com/bussmannseries
5-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**IEC and British Standard fuses — 5**
## estoy
## D16, D27, D33, D125 DIN Type D Diazed fuses
## NZ01, NZ02 DIN Type N Neozed fuses
DIN style Type D ceramic body low voltage fuses.
Ratings
- Volts 500 Vac
- Amps 2-100 A
- IR 50 kA
Agency information
- IEC 60269 and DIN 49515, CE
DIN style Type N ceramic body low voltage.
## Ratings
- Volts 400 Vac
- Amps 2-63 A
- IR 50 kA
Agency information
- IEC 60269 and DIN 49515, CE
|Catalog no.|Amps|"D" dimension|Color code|Fig.||Catalog no.<br>Amps|Catalog no.<br>Amps|Catalog no.<br>Amps|Catalog no.<br>Amps|||"D" dimension|"D" dimension|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|2D16|2|6|Pink|||2NZ01||2||||||
|4D16|4|6|Brown|||4NZ01||4||||||
|6D16|6|6|Green|||6NZ01||6||||||
|10D16|10|8|Red|1||10NZ01|10|||||||
|16D16|16|10|Grey|||16NZ01|16|||||||
|20D16|20|12|Blue|||20NZ02|20|||||||
|25D16|25|14|Yellow|||25NZ02|25|||||||
|2D27|2|6|Pink|||35NZ02|35|||||||
|4D27|4|6|Brown|||50NZ02|50|||||||
|6D27|6|6|Green|||63NZ02|63|||||||
|10D27|10|8|Red|2||Dimensions — mm||||||||
|16D27<br>16<br>10<br>Grey<br>20D27<br>20<br>12<br>Blue<br>25D27<br>25<br>14<br>Yellow<br>35D33<br>35<br>16<br>Black<br>3<br>50D33<br>50<br>18<br>White<br>63D33<br>63<br>20<br>Copper<br>80D125<br>80<br>5<br>Silver<br>4<br>100D125<br>100<br>7<br>Red<br>Additional 500 V quick acting fuses in body sizes D16, D27, D33 and<br>D125 rated 2-100 A. Reference number suffixed "Q." E.g., 10D27Q.<br>~~—~~||||||D<br>36<br>5<br>&|||||||||
|Gauge rings and keys can also be supplied.||||||||||||||
|Catalog no.|Catalog no.<br>Amps|"D" dimension|Color code|
|---|---|---|---|
|2NZ01|2|11|Pink|
|4NZ01|4|11|Brown|
|6NZ01|6|11|Green|
|10NZ01|10|11|Red|
|16NZ01|16|11|Grey|
|20NZ02|20|15|Blue|
|25NZ02|25|15|Yellow|
|35NZ02|35|15|Black|
|50NZ02|50|15|White|
|63NZ02|63|15|Copper|
Dimensions — mm
**==> picture [220 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
13.2 21.5 27.5 33.5<br>50 50 50 57<br>D D D<br>Tyee D<br>Fig. 1 Fig. 2 Fig. 3 Fig. 4<br>**----- End of picture text -----**<br>
Data sheet no. 4124
Data sheet no. 4124
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
5-9
## **5 — IEC and British Standard fuses**
## ___NHG___B NH HRC fuses
## ___NHG___B NH HRC fuses
500 Vac gG/gL dual indicator voltage conducting metal gripping lugs
DIN 000 to 4 Class: gG/gL DIN square bodied, dual indication industrial fuses with voltage conducting metal gripping lugs. They are made of a steatite insulator, corrosion-proof (aluminum) metal parts with full-contact and silver-plated copper blades. All NHG fuses feature a selectivity ratio: 1:1.6 up to 500 Vac.
|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses|parts with full-contact and silver-plated copper blades. All NHG fuses||||Amps|Catalogno.||Amps|Catalogno.|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|feature a selectivity ratio: 1:1.6 up to 500 Vac.<br>Ratings<br> Volts<br>• 500 Vac<br>• 690 Vac<br> Amps 2-1250 A<br> IR 120 kA<br> Frequency<br>• 45-62 Hz operating<br>Agency information<br>PY<br>Hoo<br>|<br>as<br>eo<br>amare<br><=oe||||||||||||||4<br>=<br>poo<br>20A<br>aeOcc<br>(24<br>LCoPbTren]|||||||<br>Stan<br>630A<br>&<br>wp<br>a"<br>“|||||||||000 size<br>2<br>2NHG000B<br>4<br>4NHG000B<br>6<br>6NHG000B<br>10<br>10NHG000B<br>16<br>16NHG000B<br>20<br>20NHG000B<br>25<br>25NHG000B<br>32<br>32NHG000B<br>35<br>35NHG000B<br>40<br>40NHG000B<br>50<br>50NHG000B<br>63<br>63NHG000B<br>80<br>80NHG000B<br>~~—SSSSSSSSSSSSSSSSSS~~||||1 size<br>50<br>50NHG1B<br>63<br>63NHG1B<br>80<br>80NHG1B<br>100<br>100NHG1B<br>125<br>125NHG1B<br>160<br>160NHG1B<br>200<br>200NHG1B<br>224<br>224NHG1B<br>250<br>250NHG1B<br>315<br>315NHG1B<br>355<br>355NHG1B<br>02 size<br>35<br>35NHG02B<br>~~—SsSSSSSSSSSSSSSSSSSS~~||
|IEC 60269, VDE 0636, DIN 43620<br> CE (500 Vac only)||||||IEC 60269, VDE 0636, DIN 43620|||||||||||||||||||||||100<br>00 size<br>50|100NHG000B<br>50NHG00B||40<br>50<br>63|40NHG02B<br>50NHG02B<br>63NHG02B|
|Dimensions — mm|Dimensions — mm|Dimensions — mm|||||||||||||||||||||||||||63|63NHG00B||80|80NHG02B|
||||||a4||||||||||||||||||||||||80<br>100|80NHG00B<br>100NHG00B||100<br>125|100NHG02B<br>125NHG02B|
||||||a3|||||||||||||||e3|||||||||125|125NHG00B||160|160NHG02B|
|||||||||||||||||||||||||2 min.||2 min.|||160|160NHG00B||200|200NHG02B|
||||||||||||d||||||c2||||||||||||0 size|||224|224NHG02B|
||||||||||||||||||||||||||||||6|6NHG0B||250|250NHG02B|
||||||||||||||||b||c1||||||||||e1||10<br>16<br>20|10NHG0B<br>16NHG0B<br>20NHG0B||2 size<br>250<br>300|250NHG2B<br>300NHG2B|
||||||||||||||||f|||||||e4|||||||25|25NHG0B||315|315NHG2B|
||||||a2|||||||||||||||e2|||||||||32|32NHG0B||355|355NHG2B|
||||||a1||||||||||||||||||||||||35|35NHG0B||400|400NHG2B|
|Fuse<br>size<br>a1|||a2|a3|a4||b||||c1|c2||D|||e1|e2||e3||||e4||f|||40<br>50|40NHG0B<br>50NHG0B||425<br>450|425NHG2B<br>450NHG2B|
|000<br>79|||54|45|49||15||||35|10||2|||41|21||16||||6||8|||63|63NHG0B||500|500NHG2B|
|00<br>79|||54|45|49||15||||35|11|7.0||||48|30||25||||6||15|||80|80NHG0B||03 size||
|0<br>125|||68|62|68||15||||35|11|2.5||||48|30||25||||6||15|||100|100NHG0B||250|250NHG03B|
|01<br>135|||75|62|68||15||||40|11|2.5||||48|30||25||||6||15|||125|125NHG0B||315|315NHG03B|
|1<br>135|||75|62|68||20||||40|11|2.5||||53|52||25||||6||15|||160|160NHG0B||355|355NHG03B|
|02<br>150|||75|62|68||20||||48|11|2.5||||53|52||25||||6||15|||01 size|||400|400NHG03B|
|2<br>150|||75|62|68||25||||48|11|2.5||||61|60||25||||6||15|||6|6NHG01B||3 size||
|03<br>150|||75|62|68||25||||60|11|2.5||||61|60||25||||6||15|||10|10NHG01B||315|315NHG3B|
|3<br>150|||75|62|68||32||||60|11|3.0||||75|70||25||||6||18|||16|16NHG01B||355|355NHG3B|
|4<br>200|||84|80|90||50||||85|11||3||120||87||—||||8||30|||20|20NHG01B||400|400NHG3B|
|Recommended fuse blocks|Recommended fuse blocks|Recommended fuse blocks|Recommended fuse blocks||||||||||||||||||||||||||25|25NHG01B||425|425NHG3B|
||||||||||||||||||||||||||||||32|32NHG01B||450|450NHG3B|
|Block catalog no.||||||Fuse size|||||||||||||||||||||||35|35NHG01B||500|500NHG3B|
|SD00-D|||||||000-00||||||||||||||||||||||40|40NHG01B||630|630NHG3B|
|SD1-D<br>SD2-D||||||1*, 1<br>02, 2, 03, 3|||||||||||||||||||||||50<br>63<br>80|50NHG01B<br>63NHG01B<br>80NHG01B||800<br>4 size*<br>500|800NHG3B<br>500NHG4G|
||||||||||||||||||||||||||||||100|100NHG01B||630|630NHG4G|
||||||||||||||||||||||||||||||125|125NHG01B||800|800NHG4G|
||||||||||||||||||||||||||||||160|160NHG01B||1000|1000NHG4G|
|||||||||||||||||||||||||||||||||1250|1250NHG4G|
## Ratings
## • Volts
- Amps 2-1250 A
- IR 120 kA
- Frequency
## Agency information
- IEC 60269, VDE 0636, DIN 43620
- CE (500 Vac only)
## Dimensions — mm
Recommended fuse blocks
|Block catalog no.|Fuse size|
|---|---|
|SD00-D|000-00|
|SD1-D|1*, 1|
|SD2-D|02, 2, 03, 3|
* Size 4 is a a single indicator fuse with slotted end blades.
Data sheet no. 10164 (500 V), 720109 (690 V)
Eaton.com/bussmannseries
5-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**IEC and British Standard fuses — 5**
## ___NHG___B NH HRC fuses
|___NHG___B NH HRC fuses|___NHG___B NH HRC fuses|___NHG___B NH HRC fuses|___NHG___B NH HRC fuses|___NHG___B NH HRC fuses|
|---|---|---|---|---|
|690 Vac gG/gL dual indicator voltage conducting metal<br>gripping lugs<br>Amps<br>Catalog no.<br>000 size<br>2<br>2NHG000B-690<br>4<br>4NHG000B-690<br>6<br>6NHG000B-690<br>Amps<br>Catalog no.<br>2 size<br>200<br>200NHG2B-690<br>224<br>224NHG2B-690<br>250<br>250NHG2B-690<br>~~==~~|||||
|10|10NHG000B-690||315|315NHG2B-690|
|16|16NHG000B-690||3 size||
|20|20NHG000B-690||250|250NHG3B-690|
|25|25NHG000B-690||315|315NHG3B-690|
|32|32NHG000B-690||355|355NHG3B-690|
|35|35NHG000B-690||400|400NHG3B-690|
|40|40NHG000B-690||425|425NHG3B-690|
|50|50NHG000B-690||500|500NHG3B-690|
|63|63NHG000B-690||4 size**||
|00 size|||630|630NHG4B-690|
|50|50NHG00B-690||800|800NHG4B-690|
|63<br>80|63NHG00B-690<br>80NHG00B-690|* 160 amps rated at 660 Vac.<br>** Size 4 is a single indicator fuse with<br>slotted end blades.|||
|100|100NHG00B-690||||
|125<br>160*<br>1 size<br>50<br>63|125NHG00B-690<br>160NHG00B-690<br>50NHG1B-690<br>63NHG1B-690||||
|80|80NHG1B-690||||
|100|100NHG1B-690||||
|125|125NHG1B-690||||
|160|160NHG1B-690||||
|200|200NHG1B-690||||
|224|224NHG1B-690||||
|250|250NHG1B-690||||
## JKS-700 fast-acting fuses
The JKS-700 is a fast-acting, current-limiting fuse that is UL Recognized and has CSA Component Acceptance for applications up to 700 Vac. The JKS-700 is available in ratings up to 60 amps with the same dimensions as a standard Class J fuses; but its voltage rating places it outside the standard Class J fuse class.
Bussmann recommends the JM70100 modular fuse block and the JM70100-MW power distribution fuse block for the 30 amp case size JKS-700 fuses. See page 8-18 for details.
## Ratings
- Volts 700 Vac (or less)
- Amps 25-60 A
> • IR
- Minimum 6In
- 200 kA RMS Sym.
Operating class aR
Agency information
- UL Recognized, 248-13 Semiconductor Fuses, File E56412
- CSA Component Acceptance, C22.2 No 248.13 Semiconductor Fuses, Class 1422-30
## Features
- Current limitation for non-inductive circuits provides currentlimiting response to maximum ground fault and short-circuit conditions
- 200 kA interrupting rating provides protection at all circuit locations
- Economical circuit protection for high-fault current circuits
## Typical applications
- Power panelboards up to 700 Vac
- Machinery disconnects up to 700 Vac
Catalog no. (amps) JKS-25-700 JKS-30-700 JKS-35-700 JKS-60-700
Data sheet no. 10164 (500 V), 720109 (690 V)
Data sheet no. 1026
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
5-11
**5 — IEC and British Standard fuses**
## SD_ and TD_ NH fuse blocks
## Shroud kits
NH fuse bases feature thermoplastic bodies, and DIN-Rail and screw mounting (size 4 is screw fix). They are available with a range of protection accessories for live parts for IP20 protection.
## Ratings
## • Volts
- 690 Vac
- 1000 Vac (SD1-D only)
- Amps up to 1250 A
- NH fuse sizes 000 to 4
## Agency information
- IEC 60269-1 and 2
- VDE 0636-1 and 2
## Typical applications
- Protecting industrial circuits and electrical apparatus
|Catalog no.|Catalog no.||||
|---|---|---|---|---|
|Fuse<br>size|Poles|Amps|Catalog no.<br>Carton<br>qty.|Accepts fuse<br>sizes|
|DIN-Rail or screw mount|||||
|00|1<br>3|160|SD00-D<br>3<br>TD00-D<br>1|000 and 00|
|1|1<br>3|250|SD1-D<br>3<br>TD1-D<br>1|01 and 1|
|2|1<br>3|400|SD2-D<br>3<br>TD2-D<br>1|02 and 2|
|3|1<br>3|630|SD3-D<br>3<br>TD3-D<br>1|03 and 3|
|Screw mount only|||||
|4|1|1250|SD4-S<br>3|4|
## Neutrals
|NH size|Amps|Catalog no.|Carton qty.|
|---|---|---|---|
|1|250|SDL-1|3|
|2|400|SDL-2|3|
|3|630|SDL-3|3|
|Catalog no.|Fits fuse block|
|---|---|
|TD00-IP20|TD00-D|
|TD1-IP20|TD1-D|
|TD2-IP20|TD2-D|
|TD3-IP20|TD3-D|
|SD00-SK|SD00-D|
|SD12-SK|SD1 and SD2|
|SD3-SK|SD3|
## Phase barrier kits
|Catalog no.|Fits fuse block|
|---|---|
|SD00-PB|SD00-D|
|SD12-PB*|SD1 and SD2|
|SD3-PB*|SD3|
* Kits include 2 phase barriers and 2 ganging links.
## Fuse extraction handle
|Size|Catalog no.|Catalog no.<br>Carton qty.|Carton qty.|
|---|---|---|---|
|C00-3|FEH|1||
Data sheet 10163
Eaton.com/bussmannseries
5-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**IEC and British Standard fuses — 5**
## Class gG IEC 60269 industrial ferrule fuses
10 to 22mm diameter IEC Class gG fuses with optional indicators (10x38mm only) and strikers. See catalog numbers for availability and ratings.
## 10x38mm, Class gG, 500 and 400 Vac, 0.5 to 50 A
|Catalogno.||||||
|---|---|---|---|---|---|
|Standard|W/indicator|Vac|Amps|IR(kA)|Holder/block|
|C10G0.5<br>—<br>0.5<br>C10G1<br>—<br>1<br>C10G2<br>—<br>2<br>~~OO~~||||||
|C10G4|—||4|||
|C10G6|—||6|||
|C10G8<br>—<br>C10G10<br>—<br>C10G12<br>—<br>C10G16<br>—<br>C10G20<br>—<br>C10G25<br>—<br>C10G32<br>—<br>C10G32<br>—<br>—<br>C10G321<br>~~——~~||500<br>400<br>400<br>500|8<br>10<br>12<br>16<br>20<br>25<br>32<br>32<br>32|120|CHM DIN-Rail*,<br>BMM block|
|—|C10G40I|500|40|||
|—|C10G50I|400|50|||
## .22x58mm, Class gG, 400, 500 and 690 Vac, 2 to 125 A
|Catalogno.|||||
|---|---|---|---|---|
|Standard|W/striker|Vac|Amps|IR(kA)<br>Holder/block|
|C22G2|—||2||
|C22G4|C22G4S||4||
|C22G6|C22G6S||6||
|C22G8|C22G8S||8||
|C22G10|C22G10S||10||
|C22G12|C22G12S||12||
|C22G16|C22G16S|690|16|80|
|C22G20|C22G20S||20|CH22 DIN-Rail*,|
|C22G25|C22G25S||25|JM70100 block|
|C22G32|C22G32S||32||
|C22G40|C22G40S||40||
|C22G50|C22G50S||50||
|C22G63<br>C22G80<br>C22G100<br>C22G125|C22G63S<br>C22G80S<br>C22G100S<br>C22G125S|500<br>400|63<br>80<br>100<br>125|120|
* Use striker version to actuate optional, external microswitch.
## Dimensions — mm
||||||C|||D<br>ry|D<br>ry|D<br>ry|D<br>ry||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||ØA|||||||||||ØE|||
|||B<br>|________||||||||||||||
|Catalog<br>symbol<br>C10G<br>C14G<br>C22G|Ø A<br>10<br>14.3<br>22|||||B<br>38<br>51<br>58|C<br>10<br>13<br>16||||Indicator/striker<br>D<br>Ø E<br>—<br>—<br>8<br>4<br>8<br>4||IEC and British|Standard fuses|
* Not recommended for use with indicator version.
## 14x51mm, Class gG, 400, 500 and 690 Vac, 1 to 50 A
|Catalogno.||||||
|---|---|---|---|---|---|
|Standard|W/striker|Vac|Amps|IR(kA)|Holder|
|C14G1<br>C14G2<br>—|—<br>—<br>C14G2S|690<br>500|1<br>2|80<br>120||
|C14G4<br>—|—<br>C14G4S|690<br>500|4|80<br>120||
|C14G6<br>—|—<br>C14G6S|690<br>500|6|80<br>120||
|C14G8<br>—|—<br>C14G8S|690<br>500|8|80<br>120||
|C14G10<br>—<br>C14G12<br>—|—<br>C14G10S<br>—<br>C14G12S|690<br>500<br>690<br>500|10<br>12|80<br>120<br>80<br>120|CH14 DIN-Rail**|
|C14G16<br>—|—<br>C14G16S|690<br>500|16|80<br>120||
|C14G20<br>—|—<br>C14G20S|690<br>500|20|80<br>120||
|C14G25<br>—|—<br>C14G25S|690|25|80||
|C14G32<br>C14G40|C14G32S<br>C14G40S|500|32<br>40|120||
|C14G50|C14G50S|400|50|||
** Not recommended for use with indicator version, use striker version to actuate optional, external microswitch
Data sheet no. 720115
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
5-13
**5 — IEC and British Standard fuses** TON
Class aM IEC 60269 industrial ferrule fuses
22x58mm, Class aM, 400, 500 and 690 Vac, 2 to 125 A
|Catalogno.<br>Standard<br>W/<br>indicator<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~a~~|Catalogno.<br>Standard<br>W/<br>indicator<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~a~~|Catalogno.<br>Standard<br>W/<br>indicator<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~a~~|Catalogno.<br>Standard<br>W/<br>indicator<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~a~~|Catalogno.<br>Standard<br>W/<br>indicator<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~a~~|Catalogno.<br>Standard<br>W/<br>indicator<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~a~~|
|---|---|---|---|---|---|
|C22M2|—|—||2||
|C22M4|—|—||4||
|C22M6|—|—||6||
|C22M8|—|—||8||
|C22M10|—|—||10||
|C22M12|—|C22M12S||12||
|C22M16|—|C22M16S|690|16|80|
|C22M20|—|C22M20S||20|CH22 DIN-Rail*,|
|C22M25|—|C22M25S||25|JM70100 block|
|C22M32|—|C22M32S||32||
|C22M40|—|C22M40S||40||
|C22M50|—|C22M50S||50||
|C22M63|—|C22M63S||63||
|C22M80<br>C22M100|—<br>—|C22M80S<br>C22M100S|500|80<br>100|120|
|C22M125|C22M125I|C22M125S|400|125||
10 to 22mm diameter IEC Class aM fuses with optional indicators (22x58mm only) and strikers. See catalog numbers for availability and ratings.
10x38mm, Class aM, 500 and 400 Vac, 0.25 to 25 A
* Not recommended for use with indicator version, use striker version to actuate optional, external microswitch.
|Catalogno.<br>Standard<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~soo~~|Catalogno.<br>Standard<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~soo~~|Catalogno.<br>Standard<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~soo~~|Catalogno.<br>Standard<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~soo~~|Catalogno.<br>Standard<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~soo~~|Catalogno.<br>Standard<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~soo~~|Catalogno.<br>Standard<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~soo~~|Catalogno.<br>Standard<br>Vac<br>Amps<br>IR(kA)<br>Holder/block<br>~~soo~~|optional, external microswitch.<br>Dimensions — mm|optional, external microswitch.<br>Dimensions — mm|optional, external microswitch.|optional, external microswitch.|optional, external microswitch.|||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|C10M0.5<br>C10M1<br>C10M2<br>~~—_—_~~|||0.5<br>1<br>2<br>~~—_——_~~|||||||C<br>re|||||D<br>7||||||
||C10M4||4|||||ØA|||||||||||ØE||
|C10M6<br>C10M8<br>C10M10<br>C10M12<br>C10M16<br>C10M20<br>C10M25<br>~~—_—~~<br>~~=~~||500<br>400|6<br>8<br>10<br>12<br>16<br>20<br>25<br>~~—_—_~~<br>~~=~~||120|CHM Din-Rail,<br>BMM block||B<br>Catalog<br>symbol<br>Ø A<br>B<br>C<br>Indicator/striker<br>D<br>Ø E<br>C10M<br>10<br>38<br>10<br>—<br>—<br>_<br>~~——~~|||||||||||||
|||||||||C14M<br>14.3|||||51|13|||||8|4|
|14x51mm, Class aM, 400, 500 and 690 Vac, 0.25 to 50 A||||14x51mm, Class aM, 400, 500 and 690 Vac, 0.25 to 50 A|14x51mm, Class aM, 400, 500 and 690 Vac, 0.25 to 50 A|||C22M<br>22|||||58|16|||||8|4|
|Catalogno.<br>Standard<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder<br>~~or~~|Catalogno.<br>Standard<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder<br>~~or~~|Catalogno.<br>Standard<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder<br>~~or~~|Catalogno.<br>Standard<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder<br>~~or~~|Catalogno.<br>Standard<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder<br>~~or~~|Catalogno.<br>Standard<br>W/striker<br>Vac<br>Amps<br>IR(kA)<br>Holder<br>~~or~~|
|---|---|---|---|---|---|
|C14M0.25|—||0.25|||
|C14M0.5|—||0.5|||
|C14M1|—|690|1|80||
|C14M2<br>—|—<br>C14M2S|500|2|80<br>120||
|C14M4<br>—|—<br>C14M4S|690<br>500|4|80<br>120||
|C14M6<br>—|—<br>C14M6S|690<br>500|6|80<br>120||
|C14M8<br>—|—<br>C14M8S|690<br>500|8|80<br>120||
|C14M10<br>—|—<br>C14M10S|690<br>500|10|80<br>120|CH14 DIN-Rail**|
|C14M12<br>—|—<br>C14M12S|690<br>500|12|80<br>120||
|C14M16<br>—|—<br>C14M16S|690<br>500|16|80<br>120||
|C14M20<br>—|—<br>C14M20S|690<br>500|20|80<br>120||
|C14M25<br>—|—<br>C14M25S|690|25|80||
|C14M32<br>C14M40|C14M32S<br>C14M40S|500|32<br>40|120||
|C14M50|C14M50S|400|50|||
** Use striker version to actuate optional, external microswitch.
Data sheet no. 720115
Eaton.com/bussmannseries
5-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**IEC and British Standard fuses — 5**
## HRC fuse holders
## CAMaster
The Bussmann series CAMaster HRC fuse holder features a unique cam-action for easy fuse removal while allowing significantly improved contact pressure between fuse carrier and base contact that enhances electrical performance. A range of lockable safety carriers for the fuse holder (catalog reference LSC), are available.
## Ratings
- Volts 690 V
- Amps up to 100 A
## Agency information
- CSA C22.2 No. 39; IEC 269 and BS88, CE
|Catalog no.|Amps<br>Details for|Fuses accepted|
|---|---|---|
|CM20CF<br>CM30CF|30<br>HRCI-CA applications<br>30|_CIF21<br>_H07C|
|CM60CF|60|_K07C|
|CM100CF|HRCII applications<br>100|_K07CR|
## Accessories
|Catalog no.<br>20BS<br>32BS|Amps<br>30<br>30|Description<br>Back stud|CAMaster accepted<br>CM20CF<br>CM30CF|
|---|---|---|---|
|60/100BS|60/100||CM60/100CF|
|GLP|All|Ganging link kit|3-Pole|
|20LSC<br>32LSCC|30<br>30|Security carrier<br>with clip|CM20CF<br>CM30CF|
|63/100LSC|60/100||CM60/100CF|
## SAFEloc
The Bussmann series SAFEloc HRC fuse holders (for use with HRCI-CB fuses) provides a positive, stress-free fuse fitting and locks it in position to ensure safe insertion and withdrawal from the base. Base contacts are fully shrouded to help protect against electric shock. Shrouds utilize simple slide/snap action allowing access to the contact terminal screws. It can be mounted on a 35mm DIN-Rail or panel-mounted with a single screw.
## Ratings
- Volts 600 V
- Amps 30-60 A
## Agency information
- Designed to accommodate the compact range of offset blade fuse to CSA C22.2 No. 106, HRCI-CB, CE
|Catalog no.*|Catalog no.*<br>Amps|Connection|Fuses accepted|||
|---|---|---|---|---|---|
|C30F||Front||||
|C30BS<br>C30FBS<br>C60F<br>C60BS|30<br>60|Back<br>Front-back<br>Front<br>Back|_CIF06<br>EK-(amp)|IEC and British|Standard fuses|
|C60FBS||Front-back||||
* For use with HRCI-CB fuses.
## Bussmann series Red Spot fuse holders
These versatile CSA Certified and IP20 finger-safe fuse holders for BS88 HRC industrial fuses are available in ratings from 20 to 400 amps.
Padlock inserts, warning carriers and fuse adapter accessories enhance safety and application flexibility.
See data sheet no. 10083 for details.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
5-15
**BUSSMANN** SERIES
## Enhanced safety. Improved system reliability. Simplified inventory.
It’s easier than ever to improve your circuit protection while efficiently reducing your fuse inventory.
Leveraging Bussmann™ series ultimate protection fuses, our Low-Peak™ Upgrade program couples the industry’s most advanced circuit protection with our extensive knowledge to deliver enganced safety, improved system reliability and simplified inventory.
In just three simple steps, you’ll save time and increase productivity. All by using Bussmann series Low-Peak fuses.
Three steps to ultimate protection:
> 1 Audit
> 2 Analyze
to fi
**==> picture [51 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 Implement<br>**----- End of picture text -----**<br>
Visit Eaton.com/bussmannseries to learn more.
Follow us on social media to get the latest product and support information.
**Photovoltaic fuses, holders, and blocks — 6**
## Contents
## Complete and reliable solar circuit protection
||Description|||||Section<br>page|
|---|---|---|---|---|---|---|
||Fuses|Fuse size|Volts|Amps|||
||PVM<br>PVS-R|13/32" x 1-1/2"<br>RK5|600<br>600|4-30<br>20-400||2|
||PV-_A10_<br>HPV<br>PV-_A14F|10x38mm<br>In-line assembly<br>14x51mm|1000<br>1000/1500<br>1000/1100|1-20<br>1-20<br>15-32||3<br>4|
||PV-_ANH_|NH1, 2, 3|1000|32-400||5|
||PV-_A10F85L<br>PV15M-4A-CT|10x85mm<br>Crimp terminal|1500<br>1500|2.25-25<br>4||6|
||PV-_A-_XL|XL 01, 1, 2, 3|1000/1500|50-600||7|
||Holder|Fuse size|Volts|Amps|||
||CHPV_|10x38mm|1000|30||8|
||Blocks<br>BPVM-_|Fuse size<br>10x38mm|Volts<br>1000|Amps<br>30||9|
|CHPV15L85<br>10x85 and<br>14x85mm<br>1500<br>32<br>10<br>SD_-S-PV<br>01XL to 3L<br>1500<br>Up to 630<br>SD_-D-PV and<br>TD_D-PV<br>NH1, 2, 3<br>1500<br>Up to 630<br>11<br>~~OO~~<br>~~OE~~<br>~~OO~~|||||||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
6-1
**6 — Photovoltaic fuses, holders and blocks**
## PVM 600 Vdc 13/32" x 1-1/2" midget PV fuses
A range of UL 248-19 fast-acting 600 Vdc 13/32" x 1-1/2" (10x38mm) midget fuses specifically designed to protect solar power systems in extreme ambient temperature, high cycling and low level fault current conditions (reverse current, multi-array fault).
**2011/65/EU**
## PVS-R 600 Vac/dc Class RK5 PV fuse
A range of UL 248-19 fastacting 600 Vdc Class RK5 fuses specifically designed to protect photovoltaic power systems in extreme ambient temperature, high cycling and low level fault current conditions (reverse current, multi-array fault).
## Ratings
## Ratings
- Volts
- Volts 600 Vdc
- Amps 4-30 A
- IR 50 kA DC (4-30 A)
## Agency information
- UL Listed 248-19, Guide JFGA, File E335324, CSA Component Certified C22.2, RoHS compliant, CE
## Watts loss
**==> picture [231 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Power loss (watts)|
|Catalog no.|Amps|0.8 In|In|
|PVM-10|10|1.0|1.9|
|PVM-15|15|1.0|1.7|
|PVM-30|30|1.6|2.9|
|Catalog no. (amps)|
|PVM-4|PVM-7|PVM-10|PVM-20|
|PVM-5|PVM-8|PVM-12|PVM-25|
|PVM-6|PVM-9|PVM-15|PVM-30|
**----- End of picture text -----**<br>
- 600 Vac to UL 248-12
- 600 Vdc to UL 248-19
- Amps 20-400 A
- IR
- 200 kA RMS Sym. AC
- 20 kA DC (20-60 A)
- 10 kA DC (70-400 A)
## Agency information
- UL Listed, Std. 248-12, Class RK5, Guide JFGA, File E335324. Photovoltaic to UL 248-19, CSA Component Certified C22.2, CE
**==> picture [231 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Catalog no. (amps)|
|PVS-R-20|PVS-R-60|PVS-R-125|PVS-R-300|
|PVS-R-25|PVS-R-70|PVS-R-150|PVS-R-350|
|PVS-R-30|PVS-R-80|PVS-R-175|PVS-R-400|
|PVS-R-35|PVS-R-90|PVS-R-200|
|PVS-R-40|PVS-R-100|PVS-R-225|
|PVS-R-50|PVS-R-110|PVS-R-250|
**----- End of picture text -----**<br>
## Features
## Features
- Specifically designed to protect photovoltaic systems in extreme ambient temperature per UL 248-19 listed
- Capable of withstanding high cycling and low level fault current conditions
- Current limitation for non-inductive circuits provides Class RK5 current-limiting response to ground fault and short-circuit conditions
- Designed for the protection and isolation of photovoltaic systems
## Typical applications
## Typical applications
- Combiner boxes
- String protectors
- Photovoltaic systems
- Inverters
Recommended fuse holders and blocks, see pages 6-8 and 6-9.
- Photovoltaic system DC safety switches
- Recombiner boxes
Recommended fuse blocks, see page 8-19.
Data sheet no. 2153
Data sheet no. 4203
Eaton.com/bussmannseries
6-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Photovoltaic fuses, holders, and blocks — 6**
## PV 1000 Vdc 10x38mm PV fuses
## Features
A range 10x38mm, 1000 Vdc PV fuses for the protection and isolation of photovoltaic strings that are specifically designed for use in PV systems with extreme ambient temperature, high cycling and low fault current conditions (reverse current, multi-array fault) string arrays. For application flexibility, the PV 10x38mm fuse is available as a cylindrical fuse as well as bolt-on, single and dual PCB tab and in-line crimp terminal versions.
**2011/65/EU** 4
## Ratings
- Volts 1000 Vdc
- Amps 1-20 A
- IR 50 kA
## Terminals and conductors
- Crimp connection for single, 75°C/90°C Cu Stranded 12-8 AWG PV wire
- Meets UL and IEC photovoltaic standards for global acceptance
- Low watts loss performance for energy efficiency
- Low temperature rise performance for more precise sizing
- In-line crimp terminal version is easy to apply in wire harness construction
## Typical applications
- Combiner boxes
- Inverters
- PV wire harnesses
Recommended fuse blocks, holders and fuseclips
- BPVM modular fuse block with optional cover, see page 6-9
- CHPV 1- and 2-pole modular fuse holders with optional open fuse indication, see page 6-8
- 1A3400-09 PCB fuseclip, see page 3-16
- HPV in-line fuse holder assembly, see page 6-4
## Agency information
- UL Listed to 248-19[†] , Guide JFGA, File E335324, IEC 60269-6 (gPV), CSA File 53787, Class 1422-30 (1-15A), 20 A Pending, CCC (1-20 A), RoHS Compliant
- Except crimp terminal version that is UL Recognized to UL 248-19, Guide JFGA2, File E335324.
|Catalog no. (amp)<br>Cylindrical<br>PV-1A10F<br>PV-2A10F<br>PV-3A10F|Catalog no. (amp)<br>Bolt-on<br>PV-1A10-T<br>PV-2A10-T<br>PV-3A10-T|PCB single pin<br>PV-1A10-1P<br>PV-2A10-1P<br>PV-3A10-1P|PCB double pin<br>PV-1A10-2P<br>PV-2A10-2P<br>PV-3A10-2P|Crimp terminal<br>PV-1A10F-CT<br>PV-2A10F-CT<br>PV31A10F-CT|Amps<br>1<br>2<br>3|Pre-arcing<br>0.15<br>1.2<br>4|I2t (A2s)<br>Total @rated volts<br>0.4<br>3.4<br>11|Watts loss<br>0.8 In<br>In<br>0.8<br>1.5<br>0.6<br>1.0<br>0.8<br>1.3|Watts loss<br>0.8 In<br>In<br>0.8<br>1.5<br>0.6<br>1.0<br>0.8<br>1.3|PV fuses, holders,|blocks and SPDs|
|---|---|---|---|---|---|---|---|---|---|---|---|
|PV-3-5A10F|PV-3-5A10-T|PV-3-5A10-1P|PV-3-5A10-2|PV-3.5A10F-CT|3.5|6.6|18|0.9|1.4|||
|PV-4A10F|PV-4A10-T|PV-4A10-1P|PV-4A10-2P|PV-4A10F-CT|4|9.5|26|1.0|1.5|||
|PV-5A10F|PV-5A10-T|PV-5A10-1P|PV-5A10-2P|PV-5A10F-CT|5|19|50|1.0|1.6|||
|PV-6A10F|PV-6A10-T|PV-6A10-1P|PV-6A10-2P|PV-6A10F-CT|6|30|90|1.1|1.8|||
|PV-8A10F|PV-8A10-T|PV-8A10-1P|PV-8A10-2P|PV-8A10F-CT|8|3|32|1.2|2.1|||
|PV-10A10F|PV-10A10-T|PV-10A10-1P|PV-10A10-2P|PV-10A10F-CT|10|7|70|1.2|2.3|||
|PV-12A10F|PV-12A10-T|PV-12A10-1P|PV-12A10-2P|PV-12A10F-CT|12|12|120|1.5|2.7|||
|PV-15A10F|PV-15A10-T|PV-15A10-1P|PV-15A10-2P|PV-15A10F-CT|15|22|220|1.7|2.9|||
|PV-20A10F|PV-20A10-T|PV-20A10-1P|PV-20A10-2P|PV-20A10F-CT|20|34|350|2.1|3.6|||
Data sheet no. 10121
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
6-3
**6 — Photovoltaic fuses, holders and blocks** ~~I~~ 1C, a HPV 1000 Vdc in-line PV fuse assembly PV 1000/1100 Vdc 14x51mm PV fuses A single-pole, non-serviceable photovoltaic in-line fuse holder and fuse assembly in an IP67 dust tight, submersible insulating boot for A range of 14x51mm PV fuses specifically designed for protecting **2011/65/EU** use in photovoltaic wire harnesses. and isolating photovoltaic strings. **2011/65/EU** These fuses are capable of Ratings interrupting low overcurrents associated with faulted PV systems • Volts (reverse current, multi-array fault). • 1000 Vdc Ratings • 1500 Vdc (HPV-D15V-4A only) • Volts |
- Amps 1-20 A
- 1000 Vdc (25 and 32 A)
- IR 33 kA
- 1100 Vdc (15 and 20 A)
## Agency information
- UL Listed to 4248-1 and 4248-19, File E 348242, CSA Component Acceptance, Class 6225 30, File # 47235, IP67 submersible, RoHS compliant, CE
## Terminals and conductors
- Crimp connection for single, 75°C/90°C Cu Stranded 12-8 AWG PV wire
## Boot material
- UL 5VA flammability resistant rated elastomer, UV resistant to UL F1 suitable for outdoor use.
## Operating and storage temperature range
- -40°C to +90°C
## Packaging
- Bulk packed in cartons, 180 fuse assemblies per carton. Carton weight 19.3 lbs (8.7543 kg).
- Fuse assemblies poly bagged with PV fuse element, two insulating boots (for lineside and loadside), and one pressure sensitive label to be applied on outside after complete assembly to the wire harness.
**==> picture [238 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Catalog no. (amps)*|
|1000 Vdc|
|HPV-DV-1A|HPV-DV-3.5A|HPV-DV-8A|HPV-DV-20A|
|HPV-DV-2A|HPV-DV-4A|HPV-DV-10A|
|HPV-DV-2.5A|HPV-DV-5A|HPV-DV-12A|
|HPV-DV-3A|HPV-DV-6A|HPV-DV-15A|
|1500 Vdc|
|HPV-D15V-4A|
**----- End of picture text -----**<br>
- Amps 15-32 A
- IR 10 kA
## Agency information
- UL Listed, Guide JFGA, File E335324. Photovoltaic to, UL 248-19, IEC 60269-6 gPV, CSA Pending, CCC Pending, RoHS compliant
**==> picture [264 x 79] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|I|[2]|t (A|[2]|s)|Watts loss|
|ee|Catalog no.|Amps|Pre-arcing|Total @ rated volts|0.8 In|In|
|PV-15A14F|15|14|265|2.1|4|
|PV-20A14F|20|27|568|2.7|5|
|PV-25A14F|25|65|943|2.7|5.1|
|PV-32A14F|32|120|1740|3.3|6.2|
**----- End of picture text -----**<br>
## Features
- Specifically designed to provide fast-acting protection under low fault current conditions associated with PV systems
- High DC voltage rating
- Demonstrated performance in extreme temperature cycling conditions
## Typical applications
- Combiner boxes
- Inverters
## Recommended fuse holder
- CH141B-PV DIN-Rail modular fuse holder, see data sheet no. 720148 for more information.
- For PV-(amp)A10F-CT fuse specifications and derating curves see data sheet no. 10121 at Eaton.com/bussmannseries.
## Recommended tools
- Sta-Kon™ terminal crimping tool, catalog no. ERG4002
- Multi-Contact assembly tool, catalog no, PV-RWZ with PV-KOI+II and PV-KOIII tapered spindles
Data sheet no.: 2157
Data sheet no. 720132
Eaton.com/bussmannseries
6-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Photovoltaic fuses, holders, and blocks — 6**
|NH 1000 Vdc blade and bolt-on PV fuses<br>A range of 1000 Vdc NH size<br>Photovoltaic (PV) fuses specifically<br>designed for protecting and<br>isolating array combiners/<br>re-combiners, disconnects and<br>inverters.<br>Ratings<br>• Volts 1000 Vdc<br>• Amps 32-400 A<br>• IR 50 kA<br>Agency information<br>• UL Listed, Guide JFGA, File E335324, Photovoltaic to UL 248-19,<br>Catalogno.<br>NH<br>size<br>Amps<br>I2t(A2S)<br>Watts loss<br>Pre-<br>arcing<br>Total @<br>1000V<br>0.8 In<br>In<br>Blade versions<br>PV-32ANH1<br>1<br>32<br>80<br>720<br>4<br>8<br>PV-40ANH1<br>40<br>185<br>1670<br>5<br>9<br>PV-50ANH1<br>50<br>400<br>3600<br>6<br>11<br>PV-63ANH1<br>63<br>470<br>4300<br>6<br>12<br>PV-80ANH1<br>80<br>640<br>5760<br>8<br>15<br>PV-100ANH1<br>100<br>1300<br>11,700<br>8<br>16<br>PV-125ANH1<br>125<br>2600<br>23,400<br>9<br>17<br>PV-160ANH1<br>160<br>5200<br>46,800<br>14<br>27<br>PV-200ANH1<br>200<br>10,200<br>82,000<br>13<br>25<br>PV-250ANH2<br>2<br>250<br>17,000<br>136,000<br>19<br>38<br>PV-300ANH3<br>300<br>32,000<br>260,000<br>24<br>40<br>PV-315ANH3<br>315<br>32,000<br>260,000<br>26<br>44<br>**2011/65/EU**<br>©~~=~~|NH 1000 Vdc blade and bolt-on PV fuses<br>A range of 1000 Vdc NH size<br>Photovoltaic (PV) fuses specifically<br>designed for protecting and<br>isolating array combiners/<br>re-combiners, disconnects and<br>inverters.<br>Ratings<br>• Volts 1000 Vdc<br>• Amps 32-400 A<br>• IR 50 kA<br>Agency information<br>• UL Listed, Guide JFGA, File E335324, Photovoltaic to UL 248-19,<br>Catalogno.<br>NH<br>size<br>Amps<br>I2t(A2S)<br>Watts loss<br>Pre-<br>arcing<br>Total @<br>1000V<br>0.8 In<br>In<br>Blade versions<br>PV-32ANH1<br>1<br>32<br>80<br>720<br>4<br>8<br>PV-40ANH1<br>40<br>185<br>1670<br>5<br>9<br>PV-50ANH1<br>50<br>400<br>3600<br>6<br>11<br>PV-63ANH1<br>63<br>470<br>4300<br>6<br>12<br>PV-80ANH1<br>80<br>640<br>5760<br>8<br>15<br>PV-100ANH1<br>100<br>1300<br>11,700<br>8<br>16<br>PV-125ANH1<br>125<br>2600<br>23,400<br>9<br>17<br>PV-160ANH1<br>160<br>5200<br>46,800<br>14<br>27<br>PV-200ANH1<br>200<br>10,200<br>82,000<br>13<br>25<br>PV-250ANH2<br>2<br>250<br>17,000<br>136,000<br>19<br>38<br>PV-300ANH3<br>300<br>32,000<br>260,000<br>24<br>40<br>PV-315ANH3<br>315<br>32,000<br>260,000<br>26<br>44<br>**2011/65/EU**<br>©~~=~~|NH 1000 Vdc blade and bolt-on PV fuses<br>A range of 1000 Vdc NH size<br>Photovoltaic (PV) fuses specifically<br>designed for protecting and<br>isolating array combiners/<br>re-combiners, disconnects and<br>inverters.<br>Ratings<br>• Volts 1000 Vdc<br>• Amps 32-400 A<br>• IR 50 kA<br>Agency information<br>• UL Listed, Guide JFGA, File E335324, Photovoltaic to UL 248-19,<br>Catalogno.<br>NH<br>size<br>Amps<br>I2t(A2S)<br>Watts loss<br>Pre-<br>arcing<br>Total @<br>1000V<br>0.8 In<br>In<br>Blade versions<br>PV-32ANH1<br>1<br>32<br>80<br>720<br>4<br>8<br>PV-40ANH1<br>40<br>185<br>1670<br>5<br>9<br>PV-50ANH1<br>50<br>400<br>3600<br>6<br>11<br>PV-63ANH1<br>63<br>470<br>4300<br>6<br>12<br>PV-80ANH1<br>80<br>640<br>5760<br>8<br>15<br>PV-100ANH1<br>100<br>1300<br>11,700<br>8<br>16<br>PV-125ANH1<br>125<br>2600<br>23,400<br>9<br>17<br>PV-160ANH1<br>160<br>5200<br>46,800<br>14<br>27<br>PV-200ANH1<br>200<br>10,200<br>82,000<br>13<br>25<br>PV-250ANH2<br>2<br>250<br>17,000<br>136,000<br>19<br>38<br>PV-300ANH3<br>300<br>32,000<br>260,000<br>24<br>40<br>PV-315ANH3<br>315<br>32,000<br>260,000<br>26<br>44<br>**2011/65/EU**<br>©~~=~~|NH 1000 Vdc blade and bolt-on PV fuses<br>A range of 1000 Vdc NH size<br>Photovoltaic (PV) fuses specifically<br>designed for protecting and<br>isolating array combiners/<br>re-combiners, disconnects and<br>inverters.<br>Ratings<br>• Volts 1000 Vdc<br>• Amps 32-400 A<br>• IR 50 kA<br>Agency information<br>• UL Listed, Guide JFGA, File E335324, Photovoltaic to UL 248-19,<br>Catalogno.<br>NH<br>size<br>Amps<br>I2t(A2S)<br>Watts loss<br>Pre-<br>arcing<br>Total @<br>1000V<br>0.8 In<br>In<br>Blade versions<br>PV-32ANH1<br>1<br>32<br>80<br>720<br>4<br>8<br>PV-40ANH1<br>40<br>185<br>1670<br>5<br>9<br>PV-50ANH1<br>50<br>400<br>3600<br>6<br>11<br>PV-63ANH1<br>63<br>470<br>4300<br>6<br>12<br>PV-80ANH1<br>80<br>640<br>5760<br>8<br>15<br>PV-100ANH1<br>100<br>1300<br>11,700<br>8<br>16<br>PV-125ANH1<br>125<br>2600<br>23,400<br>9<br>17<br>PV-160ANH1<br>160<br>5200<br>46,800<br>14<br>27<br>PV-200ANH1<br>200<br>10,200<br>82,000<br>13<br>25<br>PV-250ANH2<br>2<br>250<br>17,000<br>136,000<br>19<br>38<br>PV-300ANH3<br>300<br>32,000<br>260,000<br>24<br>40<br>PV-315ANH3<br>315<br>32,000<br>260,000<br>26<br>44<br>**2011/65/EU**<br>©~~=~~|NH 1000 Vdc blade and bolt-on PV fuses<br>A range of 1000 Vdc NH size<br>Photovoltaic (PV) fuses specifically<br>designed for protecting and<br>isolating array combiners/<br>re-combiners, disconnects and<br>inverters.<br>Ratings<br>• Volts 1000 Vdc<br>• Amps 32-400 A<br>• IR 50 kA<br>Agency information<br>• UL Listed, Guide JFGA, File E335324, Photovoltaic to UL 248-19,<br>Catalogno.<br>NH<br>size<br>Amps<br>I2t(A2S)<br>Watts loss<br>Pre-<br>arcing<br>Total @<br>1000V<br>0.8 In<br>In<br>Blade versions<br>PV-32ANH1<br>1<br>32<br>80<br>720<br>4<br>8<br>PV-40ANH1<br>40<br>185<br>1670<br>5<br>9<br>PV-50ANH1<br>50<br>400<br>3600<br>6<br>11<br>PV-63ANH1<br>63<br>470<br>4300<br>6<br>12<br>PV-80ANH1<br>80<br>640<br>5760<br>8<br>15<br>PV-100ANH1<br>100<br>1300<br>11,700<br>8<br>16<br>PV-125ANH1<br>125<br>2600<br>23,400<br>9<br>17<br>PV-160ANH1<br>160<br>5200<br>46,800<br>14<br>27<br>PV-200ANH1<br>200<br>10,200<br>82,000<br>13<br>25<br>PV-250ANH2<br>2<br>250<br>17,000<br>136,000<br>19<br>38<br>PV-300ANH3<br>300<br>32,000<br>260,000<br>24<br>40<br>PV-315ANH3<br>315<br>32,000<br>260,000<br>26<br>44<br>**2011/65/EU**<br>©~~=~~|NH 1000 Vdc blade and bolt-on PV fuses<br>A range of 1000 Vdc NH size<br>Photovoltaic (PV) fuses specifically<br>designed for protecting and<br>isolating array combiners/<br>re-combiners, disconnects and<br>inverters.<br>Ratings<br>• Volts 1000 Vdc<br>• Amps 32-400 A<br>• IR 50 kA<br>Agency information<br>• UL Listed, Guide JFGA, File E335324, Photovoltaic to UL 248-19,<br>Catalogno.<br>NH<br>size<br>Amps<br>I2t(A2S)<br>Watts loss<br>Pre-<br>arcing<br>Total @<br>1000V<br>0.8 In<br>In<br>Blade versions<br>PV-32ANH1<br>1<br>32<br>80<br>720<br>4<br>8<br>PV-40ANH1<br>40<br>185<br>1670<br>5<br>9<br>PV-50ANH1<br>50<br>400<br>3600<br>6<br>11<br>PV-63ANH1<br>63<br>470<br>4300<br>6<br>12<br>PV-80ANH1<br>80<br>640<br>5760<br>8<br>15<br>PV-100ANH1<br>100<br>1300<br>11,700<br>8<br>16<br>PV-125ANH1<br>125<br>2600<br>23,400<br>9<br>17<br>PV-160ANH1<br>160<br>5200<br>46,800<br>14<br>27<br>PV-200ANH1<br>200<br>10,200<br>82,000<br>13<br>25<br>PV-250ANH2<br>2<br>250<br>17,000<br>136,000<br>19<br>38<br>PV-300ANH3<br>300<br>32,000<br>260,000<br>24<br>40<br>PV-315ANH3<br>315<br>32,000<br>260,000<br>26<br>44<br>**2011/65/EU**<br>©~~=~~|NH 1000 Vdc blade and bolt-on PV fuses<br>A range of 1000 Vdc NH size<br>Photovoltaic (PV) fuses specifically<br>designed for protecting and<br>isolating array combiners/<br>re-combiners, disconnects and<br>inverters.<br>Ratings<br>• Volts 1000 Vdc<br>• Amps 32-400 A<br>• IR 50 kA<br>Agency information<br>• UL Listed, Guide JFGA, File E335324, Photovoltaic to UL 248-19,<br>Catalogno.<br>NH<br>size<br>Amps<br>I2t(A2S)<br>Watts loss<br>Pre-<br>arcing<br>Total @<br>1000V<br>0.8 In<br>In<br>Blade versions<br>PV-32ANH1<br>1<br>32<br>80<br>720<br>4<br>8<br>PV-40ANH1<br>40<br>185<br>1670<br>5<br>9<br>PV-50ANH1<br>50<br>400<br>3600<br>6<br>11<br>PV-63ANH1<br>63<br>470<br>4300<br>6<br>12<br>PV-80ANH1<br>80<br>640<br>5760<br>8<br>15<br>PV-100ANH1<br>100<br>1300<br>11,700<br>8<br>16<br>PV-125ANH1<br>125<br>2600<br>23,400<br>9<br>17<br>PV-160ANH1<br>160<br>5200<br>46,800<br>14<br>27<br>PV-200ANH1<br>200<br>10,200<br>82,000<br>13<br>25<br>PV-250ANH2<br>2<br>250<br>17,000<br>136,000<br>19<br>38<br>PV-300ANH3<br>300<br>32,000<br>260,000<br>24<br>40<br>PV-315ANH3<br>315<br>32,000<br>260,000<br>26<br>44<br>**2011/65/EU**<br>©~~=~~|NH 1000 Vdc blade and bolt-on PV fuses<br>A range of 1000 Vdc NH size<br>Photovoltaic (PV) fuses specifically<br>designed for protecting and<br>isolating array combiners/<br>re-combiners, disconnects and<br>inverters.<br>Ratings<br>• Volts 1000 Vdc<br>• Amps 32-400 A<br>• IR 50 kA<br>Agency information<br>• UL Listed, Guide JFGA, File E335324, Photovoltaic to UL 248-19,<br>Catalogno.<br>NH<br>size<br>Amps<br>I2t(A2S)<br>Watts loss<br>Pre-<br>arcing<br>Total @<br>1000V<br>0.8 In<br>In<br>Blade versions<br>PV-32ANH1<br>1<br>32<br>80<br>720<br>4<br>8<br>PV-40ANH1<br>40<br>185<br>1670<br>5<br>9<br>PV-50ANH1<br>50<br>400<br>3600<br>6<br>11<br>PV-63ANH1<br>63<br>470<br>4300<br>6<br>12<br>PV-80ANH1<br>80<br>640<br>5760<br>8<br>15<br>PV-100ANH1<br>100<br>1300<br>11,700<br>8<br>16<br>PV-125ANH1<br>125<br>2600<br>23,400<br>9<br>17<br>PV-160ANH1<br>160<br>5200<br>46,800<br>14<br>27<br>PV-200ANH1<br>200<br>10,200<br>82,000<br>13<br>25<br>PV-250ANH2<br>2<br>250<br>17,000<br>136,000<br>19<br>38<br>PV-300ANH3<br>300<br>32,000<br>260,000<br>24<br>40<br>PV-315ANH3<br>315<br>32,000<br>260,000<br>26<br>44<br>**2011/65/EU**<br>©~~=~~|
|---|---|---|---|---|---|---|---|
|IEC 60269-6 gPV, CSA Class 1422-30, File 53787 (32-160 A), UL|PV-350ANH3|3|350|44,500|370,000|27|45|
|Listed, IEC gPV, CSA, CCC Pending, RoHS compliant<br>Features|PV-355ANH3<br>PV-400ANH3<br>Bolt-on versions||355<br>400|44,500<br>67,500|370,000<br>550,000|28<br>30|46<br>50|
|• Compact size saves panel space and extends design flexibility|PV-63ANH1-B||63|470|4300|6|12|
|• Bolt-on versions have common hole centers for standardizing<br>busbar designs across 63-400 amp range|PV-80ANH1-B<br>PV-100ANH1-B|1|80<br>100|640<br>1300|5760<br>11,700|8<br>8|15<br>16|
|• Low power loss for greater efficiency and lower operating<br>temperature|PV-125ANH1-B<br>PV-160ANH1-B||125<br>160|2600<br>5200|23,400<br>46,800|9<br>14|17<br>27|
|• Global agency standards simplifies design considerations for<br>worldwide markets|PV-200ANH1-B<br>PV-250ANH2-B|2|200<br>250|10,200<br>17,000|82,000<br>136,000|13<br>19|25<br>38|
||PV-315ANH3-B||315|32,000|260,000|26|44|
|• Dual indication feature and optional microswitches make system<br>monitoring easier|PV-355ANH3-B<br>PV-400ANH3-B|3|355<br>400|38,000<br>61,000|310,000<br>490,000|29<br>32|48<br>50|
## Typical applications
- Recombiner boxes
- Inverters
## Recommended fuse blocks
- SD_ and TD_, see page 6-11
## Optional microswitches[†]
|Catalog no.|Tab size - mm (inch)|Connection|Volts|Amps|
|---|---|---|---|---|
|170H0236|250/6.3 (1/4)|||2|
|170H0238|110/2.8 (0.11)|Quick connect|250|2|
|BVL50|187/4.8 (3/16)|||6|
Blade versions mount in fuse blocks
† For use with bladed version.
Bolt-on versions mount directly to busbas and conductor terminals
Data sheet no. 720133
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
6-5
**6 — Photovoltaic fuses, holders and blocks**
## PV 1500 Vdc 10x85mm PV fuses
A range of 10x85mm PV fuses specifically designed for protecting and isolating photovoltaic strings. These fuse links are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault).
Mounts in Bussmann series CHPV15L85 DIN-Rail holder. See page 6-10.
## Ratings
- Volts 1500 Vdc
- Amps 2.25-30 A
- IR 30 kA, 1 ms
**2011/65/EU** r
## Agency information
- UL 248-19
- IEC 60269
- RoHS compliant
## Features
- Designed for fast-acting protection under low fault current conditions associated with PV systems
- UL and IEC photovoltaic standards for global product acceptance
- Low watts loss for greater PV system efficiency
## Typical applications
- Combiner boxes, wire harnesses
## Operating class
- gPV
||||I2t (A2s)||Watts loss (W)|
|---|---|---|---|---|---|
|Catalog no.|Amps|Pre-arcing|Total at 1500 Vdc|0.8 In|In|
|PV-2.25A10F85L|2.25|3|10|1.4|2.4|
|PV-2.5A10F85L|2.5|4|10|1.3|2.1|
|PV-3A10F85L|3|7|20|1.3|2.2|
|PV-3-5A10F85L|3.5|10|20|1.6|2.6|
|PV-4A10F85L|4|15|30|1.7|2.8|
|PV-5A10F85L|5|33|60|1.7|2.8|
|PV-12A10F85L|12|19|240|2.1|3.5|
|PV-15A10F85L|15|42|300|2.2|3.6|
|PV-16A10F85L|16|48|350|2.1|3.5|
|PV-20A10F85L|20|108|800|2.7|4.5|
|PV-25A10F85L|25|190|1400|3.4|5.6|
|PV-30A10F85L|30|268|1090|4.0|6.6|
## Data sheet no. 10658
## PV15M-4A-CT 1500 Vdc in-line PV fuse with crimp terminals
Bussmann series PV15M-4A-CT is a 1500 Vdc in-line photovoltaic fuse with crimp terminals for use in wire harnesses and other applications where an in-line PV fuse is desirable.
This in-line fuse can be electrically insulated with customer-supplied overmolding or approved heat-shrink.
## Ratings
- **2011/65/EU**
- • Volts 1500 Vdc • Amps 4 A • IR 15 kA DC Sey
- Time constant 3 ms max.
## Agency information
- UL Recognized, 248-19, File E484317 Vol. 1 Sec. 1, CSA pending, RoHS compliant
## Catalog number
- PV15M-4A-CT
## Conductor
- Single PV stranded 75/90°C Cu
## Operating temperature range
- -40°C to 90°C
## Materials
- Copper terminals with ceramic fuse body
## Features
- Crimp terminals eliminate the need for a fuse holder or block
- 1500 Vdc rating is ideally suited for today's efficient, higher-voltage PV systems
## Recommended tools
## Data sheet no. 10639
Sta-Kon[®] terminal crimping tool, catalog no. ERG4002
Eaton.com/bussmannseries
6-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Photovoltaic fuses, holders, and blocks — 6**
## STON mt
## XL 1000 Vdc and 1500 Vdc PV fuses
## Features
A range of XL size PV fuses specifically designed for protecting and isolating photovoltaic array combiners and disconnects. These fuses are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault). Optional microswitches available for use in monitoring systems.
## Ratings
- Ratings **2011/65/EU**
- • Volts • 1000 Vdc (63-600 A) at the
- 1000 Vdc (63-600 A)
- 1500 Vdc (50-500 A)
- Amps (see table)
- IR (see table)
## Agency information
- UL 248-19, Guide JFGA, File E335324, IEC 60269-6 gPV, CSA Class 1422-30, File 53787, RoHS Compliant
- High DC voltage rating with fast-acting protection under low fault current conditions for PV systems
- Blade or bolt-on mounting for application flexibility
- Demonstrated performance in extreme temperature cycling conditions
## Typical applications
- Recombiner boxes, Inverters
Recommended fuse blocks
- SD_-S-PV blocks, see page 6-10
Optional microswitches
- Blade: 170H0235 or 170H0237 for size 01XL, 70H0236 or 170H0238 for sizes 1XL, 2XL and 3L
> • Bolt-on: 170H0069 for all sizes
|XL size<br>Catalogno.<br>Amps<br>IR(kA)<br>I2t(A2s)<br>Watts loss<br>Bladed version<br>Bolt-on version<br>Pre-arcing<br>Total@rated volts<br>0.8I~~n~~<br>I~~n~~<br>1000 Vdc<br>~~————————~~|XL size<br>Catalogno.<br>Amps<br>IR(kA)<br>I2t(A2s)<br>Watts loss<br>Bladed version<br>Bolt-on version<br>Pre-arcing<br>Total@rated volts<br>0.8I~~n~~<br>I~~n~~<br>1000 Vdc<br>~~————————~~|XL size<br>Catalogno.<br>Amps<br>IR(kA)<br>I2t(A2s)<br>Watts loss<br>Bladed version<br>Bolt-on version<br>Pre-arcing<br>Total@rated volts<br>0.8I~~n~~<br>I~~n~~<br>1000 Vdc<br>~~————————~~|XL size<br>Catalogno.<br>Amps<br>IR(kA)<br>I2t(A2s)<br>Watts loss<br>Bladed version<br>Bolt-on version<br>Pre-arcing<br>Total@rated volts<br>0.8I~~n~~<br>I~~n~~<br>1000 Vdc<br>~~————————~~|XL size<br>Catalogno.<br>Amps<br>IR(kA)<br>I2t(A2s)<br>Watts loss<br>Bladed version<br>Bolt-on version<br>Pre-arcing<br>Total@rated volts<br>0.8I~~n~~<br>I~~n~~<br>1000 Vdc<br>~~————————~~|XL size<br>Catalogno.<br>Amps<br>IR(kA)<br>I2t(A2s)<br>Watts loss<br>Bladed version<br>Bolt-on version<br>Pre-arcing<br>Total@rated volts<br>0.8I~~n~~<br>I~~n~~<br>1000 Vdc<br>~~————————~~|XL size<br>Catalogno.<br>Amps<br>IR(kA)<br>I2t(A2s)<br>Watts loss<br>Bladed version<br>Bolt-on version<br>Pre-arcing<br>Total@rated volts<br>0.8I~~n~~<br>I~~n~~<br>1000 Vdc<br>~~————————~~|XL size<br>Catalogno.<br>Amps<br>IR(kA)<br>I2t(A2s)<br>Watts loss<br>Bladed version<br>Bolt-on version<br>Pre-arcing<br>Total@rated volts<br>0.8I~~n~~<br>I~~n~~<br>1000 Vdc<br>~~————————~~|XL size<br>Catalogno.<br>Amps<br>IR(kA)<br>I2t(A2s)<br>Watts loss<br>Bladed version<br>Bolt-on version<br>Pre-arcing<br>Total@rated volts<br>0.8I~~n~~<br>I~~n~~<br>1000 Vdc<br>~~————————~~|
|---|---|---|---|---|---|---|---|---|
||PV-63A-01XL|PV-63A-01XL-B|63|50|260|1900|13|24|
||PV-80A-01XL|PV-80A-01XL-B|80|50|490|3600|17|29|
|01|PV-100A-01XL|PV-100A-01XL-B|100|50|870|6300|18|32|
||PV-125A-01XL|PV-125A-01XL-B|125|50|1930|13,900|20|40|
||PV-160A-01XL|PV-160A-01XL-B|160|50|3900|28,100|22|44|
|1|PV-200A-1XL|PV-200A-1XL-B|200|33|9400|27,260|31|60|
||PV-160A-2XL|PV-160A-2XL-B|160|33|2780|21,000|25|44|
||PV-200A-2XL|PV-200A-2XL-B|200|33|4950|37,000|28|50|
||PV-250A-2XL|PV-250A-2XL-B|250|33|9450|70,000|34|60|
||PV-315A-2XL|PV-315A-2XL-B|315|33|16,600|123,000|40|66|
|2|PV-355A-2XL<br>—|PV-355A-2XL-B<br>PV-160A-2XL-3B*|355<br>160|33<br>33|26,000<br>2780|192,000<br>21,000|42<br>25|68<br>44|
||—|PV-200A-2XL-3B*|200|33|4950|37,000|28|50|
||—|PV-250A-2XL-3B*|250|33|9450|70,000|34|60|
|3<br>1500 Vdc|—<br>—<br>PV-350A-3L<br>PV-400A-3L<br>PV-500A-3L<br>PV-600A-3L|PV-315A-2XL-3B*<br>PV-355A-2XL-3B*<br>PV-350A-3L-B<br>PV-400A-3L-B<br>PV-500A-3L-B<br>PV-600A-3L-B|315<br>355<br>350<br>400<br>500<br>600|33<br>33<br>50<br>50<br>50<br>50|16,600<br>26,000<br>31,000<br>44,500<br>85,000<br>137,000|123,000<br>192,000<br>161,200<br>231,400<br>442,000<br>712,400|40<br>42<br>40<br>48<br>50<br>80|66<br>68<br>65<br>82<br>85<br>108|
||PV-50A-01XL-15|PV-50A-01XL-B-15|50|30|175|1000|14|25|
||PV-63A-01XL-15|PV-63A-01XL-B-15|63|30|362|2250|15|26|
||PV-80A-01XL-15|PV-80A-01XL-B-15|80|30|565|3300|19|35|
|01|||||||||
||PV-100A-01XL-15|PV-100A-01XL-B-15|100|30|1100|6600|22|40|
||PV-125A-01XL-15|PV-125A-01XL-B-15|125|30|2200|10500|23|42|
||PV-160A-01XL-12|PV-160A-01XL-B-12|160|30|5000|24000|26|52|
||PV-100A-1XL-15|PV-100A-1XL-B-15|100|30|1250|6000|24|43|
||PV-125A-1XL-15|PV-125A-1XL-B-15|125|30|1950|9360|25|52|
|1|||||||||
||PV-160A-1XL-15|PV-160A-1XL-B-15|160|30|4200|20,160|30|58|
||PV-200A-1XL-15|PV-200A-1XL-B-15|200|30|9400|45,120|31|61|
||PV-125A-2XL-15|PV-125A-2XL-B-15|125|30|2200|15,000|25|44|
||PV-160A-2XL-15|PV-160A-2XL-B-15|160|30|5000|32,000|29|48|
||PV-200A-2XL-15|PV-200A-2XL-B-15|200|30|8800|51,000|32|57|
|2|PV-250A-2XL-15|PV-250A-2XL-B-15|250|30|16,600|85,000|40|70|
||—|PV-125A-2XL-3B-15*|125|30|2200|15,000|25|44|
||—|PV-160A-2XL-3B-15*|160|30|5000|32,000|29|48|
||—|PV-200A-2XL-3B-15*|200|30|8800|51,000|32|57|
||—|PV-250A-2XL-3B-15*|250|30|16,600|85,000|40|70|
||PV-250A-3L-15|PV-250A-3L-B-15|250|100|74,000|263,000|28|49|
||PV-315A-3L-15|PV-315A-3L-B-15|315|100|150,000|533,000|30|52|
||PV-350A-3L-15|PV-350A-3L-B-15|350|100|195,000|693,000|34|59|
|3|PV-355A-3L-15|PV-355A-3L-B-15|355|100|195,000|693,000|34|59|
||PV-400A-3L-15|PV-400A-3L-B-15|400|100|296,000|1,060,000|35|61|
||PV-450A-3L-15|PV-450A-3L-B-15|450|100|412,000|1,470,000|39|67|
||PV-500A-3L-15|PV-500A-3L-B-15|500|100|532,000|1,890,000|42|73|
- These fuses have revised bolting patterns that are identical to size 3L bolting pattern to allow using both size 2XL and size 3L fuses without changing the dimensional layout of the inverter, combiners and disconnects.
Data sheet no. 10201
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
6-7
**6 — Photovoltaic fuses, holders and blocks**
CHPV Modular, IP20 finger-safe DIN-Rail holders for 10x38mm fuses
## Features
- Enhanced safety with IP20 finger-safe construction
- Wiring flexibility with terminals rated for use with 75°C or 90°C solid, stranded and fine stranded wire, and spade terminals and comb busbars. (Use any higher temperature insulations at the 90°C ampacity with appropriate derating.)
Bussmann series CHPV DIN-Rail fuse holders are for 10x38mm IEC and UL photovoltaic fuses rated up to 1000 Vdc. They are available with and without indication in 1- and 2-pole IP20 finger-safe versions. A variety of accessories extends their application flexibility and they may be ganged together to meet specific application requirements.
- Complete range of UL Listed and high SCCR rated one- and threephase finger-safe comb busbars and power feed lugs
**==> picture [374 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
Optional open fuse indicator<br>Fuse access door IP20 finger-safe<br>accommodates construction<br>4mm lockout/<br>2011/65/EU tagout device<br>Captive phil-slot<br>terminal screw<br>Toolless<br>ganging for Fork lug<br>multiple poles connection<br>Of Dual conductor<br>Toolless 35mm rated box lug<br>DIN-Rail mounting clamp<br>Wire strip gauge<br>**----- End of picture text -----**<br>
## Ratings
- Volts 1000 Vdc (or less)
- Amps 30 A
- SCCR 33 kA DC
## Agency information
- UL Listed to 4248-19, Guide IZMR, File E348242
- CSA, Class 6225-30, File 47235
- IEC 60269-2
- CCC
- RoHS compliant
- CE
Mounting 35mm DIN-Rail
Wire range - AWG (mm[2] )
- 75°C and 90°C* Cu
- 18-4 (0.8[-] 21.1)
- Solid, stranded, fine stranded
- May be used with higher temperature rated conductors with appropriate derating.
Gang multiple poles to meet application requirements using kit catalog number JV-L (gangs up to four poles).
## Terminals
- Single or dual conductors
- Comb busbar
Torque 30 lb-in (3.4 N•m) maximum
Flammability UL 94V0, self-extinguishing
## Storage and operating temperature
- -4°F (-20°C) to 194°F (90°C) indicating
- -4°F (-20°C) to 248°F (120°C) non-indicating
|Catalogno.<br>With indication*|Without indication|Volts/amps|Agencymarks|Poles<br>SCCR|Recommended<br>Bussmann series fuses|
|---|---|---|---|---|---|
|CHPV1IU<br>CHPV2IU|CHPV1U<br>CHPV2U|1000 Vdc/30 A|UL, CSA, , UL 4248-18, IEC 60269-1, CCC|1<br>33 kA DC<br>2|PV-(amp)A10F,<br>PV10M-(amp)|
* All models require 90 V minimum for illumination.
Data sheet no. 10430
Eaton.com/bussmannseries
6-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Photovoltaic fuses, holders, and blocks — 6**
## BPVM modular blocks for 10x38mm fuses
The Bussmann series BPVM modular style 1000 Vdc fuse blocks for use with 10x38mm
**==> picture [29 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
(13/32” x 1-1/2”) photovoltaic fuses up to 30 amps contain multiple features to add versatility, reduce labor and enhance safety of any panel design. Optional IP20 fingersafe covers enhance safety with a lockout/tagout feature along with optional open fuse indication to speed troubleshooting.
## Ratings
- Volts 1000 Vdc
- Amps 30 A
- SCCR 33 kA
## Agency information
BPVM-2C with CVRI-CCM covers
- Blocks
- UL Listed, Guide IZMR, File E348242
- CSA Component Acceptance, Class 6225-01, File 47235
- RoHS compliant
- Available in 1- and 2-pole configurations to meet stocking requirements
- Blocks are fully modular with a snap-together design that provides tool-less assembly of multiple pole blocks at point-of-use to reduce inventory and save assembly time and labor
- DIN-Rail and panel mount versatility allows one product to be used for multiple applications, lowering inventory cost
- Compact footprint consumes minimal panel space
- Optional see-through cover enhances safety with IP20 finger-safe protection, lockout/tagout capability and open circuit indication
- Easy circuit identification with available universal marker labels for fuse block covers
- Tin-plated bimetallic copper fuse clips deliver superior fatigue resistance compared to traditional spring brass
- Listed to UL 4248-18 for photovoltaic application
## Terminal specifications for 75/90°C Cu and Al wire
|Terminal type|AWG range|Torque lb-in (N•m)|
|---|---|---|
|||Cu 2-3 — 50 (5.6)|
|||Cu 4-6 — 45 (5.1)|
|Box lug (“CR” Option)|Cu 2-14, Al 2-8|Cu 8-14 — 35 (4.0)<br>Al 2-6 — 50 (5.6)|
|||Al 8 — 40 (4.5)|
|Screw (S)|Cu 10-18|10-18 — 20 (2.3)|
## • CE
- Covers
- Covers are included in the overall UL Listing and CSA Acceptance
- IP20 finger-safe
- RoHS Compliant
|Catalogno.||||
|---|---|---|---|
|Terminal type<br>#10-32 Phil-<br>slot screw|Box lug|Poles|Fuse size/class|
|BPVM-1S<br>BPVM-2S|BPVM-1C<br>BPVM-2C|1<br>2|10x38mm (13/32" x 1-1/2”) gPV and PV|
## Poles
- 1-, 2-pole units factory assembled
- Single-pole units snap together to create desired number of poles
## Flammability ratings
- Blocks — UL 94V0, self-extinguishing
|Recommended covers*<br>Coverpart numbers<br>Indicating<br>CVRI-CCM|Non indicating<br>CVR-CCM|PV fuses, holders,|blocks and SPDs|
|---|---|---|---|
## Recommended covers*
- For use with 4 AWG max conductors.
- Covers — UL 94HB, self-extinguishing
Operating and storage temperature range
- Blocks -40°C to +120°C
- Non-Indicating covers -40°C to +120°C
- Indicating covers -20°C to +90°C*
- Indication requires minimum 90 Vac/dc and closed circuit to illuminate.
## Recommended Bussmann series fuses
- 10x38mm PV fuses
- Fast-acting 600 Vdc PVM fuses
- Class gPV 1000 Vdc PV fuses
## Recommended DIN-Rail end stops
- Catalog no. BRKT-ND or BRKT-NDSCRW2
## Features
Data sheet no. 10265
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
6-9
## **6 — Photovoltaic fuses, holders and blocks**
## CHPV15L85 holder for 10x85mm and 14x85mm fuses
CHPV15L85 fuse holder can be used with 10x85mm and 14x85mm cylindrical gPV fuses.
The unique design offers a high degree of safety with no possibility of any accidental contact with live parts during fuse replacement. When the fuse carrier is extracted, it continues to cover the live parts.
Ratings
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- Volts 1500 Vdc
- Amps 32 A (UL and IEC)
## SD blocks for XL size PV fuses
SD XL PV fuse blocks are available with integral shields specifically designed to be fitted with Bussmann series XL photovoltaic fuses (see data sheet 10201).
## Ratings
- Volts 1500 Vdc
- Amps
- 250 A **2011/65/EU**
- • 400 A • 630 A
- SCCR 50 kA
- Impulse withstand Uimp 12 kV (tested at 18.5 kV)
## Agency information
- cULus 4248-1 Edition 1, File E384242
- cULus 4248-19 Edition 1, File E14853
- IEC 60269-1
- RoHS compliant
Poles 1
## Agency information
- IEC 60269-1
- UL Listed, File E348242
- RoHS complaint
## Poles
- 1
- Power acceptance
- Sizes 01XL and 1XL: 56 W
- Size 2XL: 70 W
Fuse rated power dissipation
- Up to 8.5 W max
## Protection level
- IP20
Storage and operating temperature range
- Minimum permitted ambient temperature: -40°C (installation only at temperatures > -5°C). Service conditions as per IEC 61439-1, maximum pollution degree 3.
## Mounting
- 35mm DIN-Rail
Terminals
- Size 3L: 96 W
## Protection level
- IP20 with terminal covers and gripping lug cover in place and shielding of any exposed part of the terminal lugs
## Operating temperature range
- -45°C to 80°C (with fuse derating above 40°C)
## Mounting
- Panel
UL94 Flammability rating
- Block V-2
> • Terminal cover V-0
- Box terminal, Cu 4-10mm[2] flexible, directly clamped or with wireend ferrules (flexible + wire-end ferrule may not be possible with maximum cross-section)
## To order
- Specify catalog number CHPV15L85
## Features
- Global accreditation
- 32 amp current rating for UL and IEC
|Catalog no.<br>Description<br>XL fuse size<br>Amps<br>~~ee~~|Catalog no.<br>Description<br>XL fuse size<br>Amps<br>~~ee~~|Catalog no.<br>Description<br>XL fuse size<br>Amps<br>~~ee~~|
|---|---|---|
|SD1XL-S-PV|01XL and 1XL|250|
|SD2XL-S-PV|1-pole PV fuse block<br>2XL|400|
|SD3L-S-PV|3L|630|
|Accessory|||
|Catalog no.<br>Description<br>~~kee~~|||
|FEH1500|Fuse extraction handle available for sizes 01XL to 3L|Fuse extraction handle available for sizes 01XL to 3L|
## Compatible Bussmann series fuses
- PV-xA10F85 10x85mm fuses
- PV-xxA14LF10F 14x85mm fuses
Data sheet no. 10066
Data sheet no. 10628
Eaton.com/bussmannseries
6-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Photovoltaic fuses, holders, and blocks — 6**
## SD and TD blocks for NH size PV fuses
SD PV fuse blocks for NH fuse sizes 1 to 3 NH are available in 1- and 3-pole versions and are specifically designed for use with Bussmann series bladed NH photovoltaic fuses (see data sheet 720133).
## Ratings
## • Volts
- 1500 Vdc (IEC)
- Amps
- Amps • 250 A (SD1) **2011/65/EU** • 400 A (SD2) • 630 A (SD3)
- • SCCR 50 kA Agency information • IEC 60269-1 • UL Listed, File E348242 “®
- UL Listed, File E348242
- CSA File 47235
- RoHS compliant
## Poles
## Flammability rating
> • UL 94V0
|• UL 94V0|• UL 94V0||||
|---|---|---|---|---|
|Catalog no.<br>SD1--D-PV<br>~~_~~||Poles<br>Description<br>1|NH fuse size<br>1|Amps<br>250|
||TD1--D-PV|3|||
||SD2-D-PV|1|||
||TD2-D-PV|NH PV fuse block<br>3|2|400|
||SD3-D-PV<br>TD3-D-PV|1<br>3|3|630|
Accessories
## Fuse extraction handle
|Catalog no.<br>FEH<br>Shroud kits||Size<br>NH1 to 3||Amps<br>250 to 630|
|---|---|---|---|---|
|Catalog no.*|Fuse block|Fuse size|Amps|Description|
|SD12-SK|SD1 and TD1|NH1|250||
|||||Includes 2|
|SD12-SK|SD2 and TD2|NH2|400|shrouds and 1|
|||||fuse cover|
|SD3-SK|SD3 and TD3|NH3|630||
- 1 and 3
* Order one kit per pole.
Power acceptance Shown with optional shroud kit
- SD1 - 32 W
- SD2 - 45 W
- SD3 - 60 W
## Protection level
- IEC - IP20 with shroud kit installed and shielding of any exposed terminal lugs
- UL - Installation of shroud kit decreases the likelihood of incidental terminal contact. To ensure compliance to IP20 specifications per UL the installer must make additional provisions.
## Operating temperature range
- IEC Standards -20°C to 70°C
- UL -20°C to 90°C Max*
- Dependant upon rating of customer supplied lugs.
## Storage temperature range
- IEC and UL -40°C to 90°C
Phase barrier kits
|Catalog no.†<br>Fuse block<br>Fuse size<br>Amps<br>Description<br>SD12-PB<br>SD1 and TD1<br>NH1<br>250<br>~~a~~|Catalog no.†<br>Fuse block<br>Fuse size<br>Amps<br>Description<br>SD12-PB<br>SD1 and TD1<br>NH1<br>250<br>~~a~~|Catalog no.†<br>Fuse block<br>Fuse size<br>Amps<br>Description<br>SD12-PB<br>SD1 and TD1<br>NH1<br>250<br>~~a~~|Catalog no.†<br>Fuse block<br>Fuse size<br>Amps<br>Description<br>SD12-PB<br>SD1 and TD1<br>NH1<br>250<br>~~a~~|Catalog no.†<br>Fuse block<br>Fuse size<br>Amps<br>Description<br>SD12-PB<br>SD1 and TD1<br>NH1<br>250<br>~~a~~|
|---|---|---|---|---|
|SD12-PB|SD2 and TD2|NH2|400|2 phase barriers<br>and 2 ganging|
|SD3-PB|SD3 and TD3|NH3|630|links|
† Order one kit per pole.
## Microswitches
||Catalog no.<br>BVL50||6 A 250 Vac|Ratings<br>6 A 250 Vac|
|---|---|---|---|---|
||170H0236||2 A 250 Vac|2 A 250 Vac|
||170H0238||2 A 250 Vac|2 A 250 Vac|
|Neutral links<br>Catalog no.<br>Fuse block<br>Fuse size<br>Amps<br>SDL-1<br>SD1 and TD1<br>NH1<br>250<br>~~_~~<br>~~EEE~~|||||
||SDL-2|SD2 and TD2|NH2|400|
||SDL-3|SD3 and TD3|NH3|630|
## Mounting
- 35mm DIN-Rail
- Panel
Data sheet no. 720149
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
6-11
**BUSSMANN** SERIES
## Bussmann series products at your fingertips
We make searching for and selecting Bussmann™ series products easy with four unique product selector tools:
Surge Protective Device Selector Low Voltage Fuses Selector Medium Voltage Fuse Selector Connector Selector
Each tool allows you to select from available attributes to find the product that best meets your needs. Results are then displayed with links to product detail webpages for more information. Quick access to our team of experts for additional assistance is also made available. And with a responsive design, the tools can be used anytime, anywhere.
Find these selector tools and more at toolbox.bussmann.com.
Follow us on social media to get the latest product and support information.
**Medium voltage fuses — 7**
## Contents
||Description<br>Section<br>page<br>Introduction<br>2<br>~~ee~~|Description<br>Section<br>page<br>Introduction<br>2<br>~~ee~~|
|---|---|---|
|A fusible solution for virtually|E-Rated current-limiting||
|every medium voltage|2.75 kV<br>5.5 kV|3-4<br>5-7|
||5.5 kV specialty mount<br>8.3 kV|8-10<br>11-12|
||8.3 kV specialty mount|13-14|
||15.5 kV|15-17|
||15.5 kV specialty mount|18-19|
||DIN E-Rated current-limiting — 5.5-38 kV|20-21|
||R-Rated current-limiting||
||2.4 kV|22|
||4.8 kV|23-24|
||7.2 kV|25|
||PT E-Rated current-limiting — 2.475-38 kV|26-29|
||PT fast-acting current-limiting|30|
||British IEC|31|
||DIN IEC|32|
|' a|Expulsion fuse links<br>33<br>EEI-NEMA Type K and T – Type H and N<br>34<br>PT fuse mountings<br>35<br> ~~OO~~||
||Recommended fuseclips|36|
A fusible solution for virtually every medium voltage application
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-1
**7 — Medium voltage fuses**
## Introduction
## Worldwide circuit protection solutions
Eaton is the world-leading supplier of Bussmann series medium voltage fuses. Each product is backed by an efficient worldwide distribution network with unrivaled service and technical support. Eaton circuit protection solutions comply with major international standards: ANSI, BS, DIN, IEC and UL.
## Fuse types
Medium voltage fuses generally fit into two categories – expulsion fuses and current limiting. The definitions per ANSI C37.40 are:
Expulsion fuse: A vented fuse in which the expulsion effect of the gases produced by internal arcing, either alone or aided by other mechanisms results in current interruption. Expulsion fuses will limit the duration of an overcurrent event, but they will not limit the magnitude of fault current.
Current-limiting fuse: A fuse unit that, when in its currentresponsive element is melted by a current within the fuse’s specified current-limiting range, abruptly introduces a high resistance to reduce current magnitude and duration, resulting in subsequent current interruption. A current limiting fuse will reduce the magnitude a fault current as well as limit the duration of the overcurrent event when operating in its current limiting range. Eaton offers a broad range of current limiting fuses for protection of feeders, transformers and motor circuits designed to ANSI, BS, DIN and IEC standards.
## E- and R-Rated fuses
In North America, current limiting fuses typically fall into the category of E-Rated fuses and R-Rated fuses. Eaton also offers a wide range of Bussmann series current limiting fuses designed to BS, DIN and IEC standards.
E-Rated fuses are used to protect feeder circuits, power transformers and potential transformers. E-Rated fuses have defined current response times specified by ANSI C37.46. E-Rated fuses 100 amps and below must melt in 300 seconds at an RMS current within the range of 200 to 240 percent of the continuous current rating. E-Rated fuses above 100 amps must melt in 600 seconds at an RMS current within the range of 220 to 264 percent of the continuous current rating of the fuse. Eaton offers a wide variety of full range and general purpose E-Rated fuses from 2.4 to 38 kV.
R-Rated fuses are back-up fuses that provide short-circuit protection for motor circuits. They are applied with medium voltage motor starters which provide the overload protection for the circuit. R-Rated fuses also have defined current response times specified by ANSI C37.46. R-Rated fuses will melt in a range of 15 to 35 seconds at a current equal to 100 times the “R” rating. Bussmann series R-Rated fuses for motor circuit protection are available in voltage ratings from 2.4 to 8.3 kV
## Medium voltage current-limiting fuses
Current-limiting fuses are classified into three categories:
1. Full range – defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum rated interrupting current down to the minimum continuous current that causes the melting of the fusible element(s), when the fuse is applied at the maximum ambient temperature specified by the manufacturer.” It is able to interrupt any current that will melt its element.
2. General purpose – defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum rated interrupting current down to the current that causes melting of the fusible element(s) in one hour.” Not all currents fall within this range. It is possible for the fuse to be exposed to an overcurrent lower than the value given by the one hour criteria. In that case, a different overcurrent protection device would be required to interrupt the overcurrent.
3. Back-up – defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum interrupting rating current down to the minimum interrupting current.” The minimum interrupting current is the lowest current that the fuse will be able to clear properly. This creates a need to place a low current interrupting device, such as motor overloads, in series with the back-up rated fuse.
Eaton.com/bussmannseries
7-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## wee seme
## 2.75 kV E-Rated medium voltage ferrule fuses
Dimensions — in (mm)
## Catalog symbols
|2.75 kV E-Rated medium voltage ferrule fuses<br>Catalog symbols<br>wee seme|2.75 kV E-Rated medium voltage ferrule fuses<br>Dimensions — in (mm)|||||
|---|---|---|---|---|---|
|Catalog symbols|C<br>ee|||||
|2CLE-_E<br>JCX-_E<br>Ratings<br>Volts 2.75 kV<br>Amps 10 to 450 A<br>Interrupting ratings<br>• 50 kA RMS Sym. (2CLE-_E)<br>• 40 kA RMS Sym. (JCX-_E)<br>Agency information|3.31<br>(84.1)<br>B<br>B<br>A<br><5<br>in<br>~~oe~~|||||
- 2CLE-_E
- JCX-_E
Ratings
- Volts 2.75 kV
- Amps 10 to 450 A
- Interrupting ratings
## Agency information
- E-Rated fuses meet the performance characteristics of ANSI C37.46
## Recommended CLE fuse holders
|||||||Catalogno.||||
|---|---|---|---|---|---|---|---|---|---|
|Amps|Fuse mounting<br>type|BIL<br>(kV)|Approx. dimensions — in (mm)<br>Diameter A<br>Clipcenter B<br>Length C|||Mounting*<br>Porcelain<br>insulator|Glass-polyester<br>insulator|Live parts<br>(with end<br>fittings)|End fittings<br>(disconnect<br>only)|
|CLE||||||||||
|15E–25E<br>Single barrel|Non-disconnect<br>Disconnect†||2 (51)|8.1 (206)|9.5 (241)|2CLE-PNM-C<br>2CLE-PDM-C|2CLE-GNM-C<br>2CLE-GDM-C|CLE-NL-C<br>CLE-DL-C|—<br>CLE-DF-C|
|10E–225E|Non-disconnect|||||2CLE-PNM-D|2CLE-GNM-D|CLE-NL-D|—|
|Single barrel|Disconnect†|60||||2CLE-PDM-D|2CLE-GDM-D|CLE-DL-D|CLE-DF-D|
|250E–300E|Non-disconnect||3 (76)|7 (178)|10.9 (277)|2CLE-PNM-E|2CLE-GNM-E|CLE-NL-E|—|
|350X-450X||||||||||
|Double barrel|Disconnect†|||||2CLE-PDM-E|2CLE-GDM-E|CLE-DL-E|CLE-DF-E|
* Includes live parts and end fittings, end fittings supplied only when required.
- Disconnect mountings provide a means for fuse extraction only. Do not use a disconnect mounting for load switching or fuse removal while energized.
Recommended fuseclips
|Description<br>Fuse dia. — in (mm)<br>Catalogno.<br>~~ee~~|Description<br>Fuse dia. — in (mm)<br>Catalogno.<br>~~ee~~|Description<br>Fuse dia. — in (mm)<br>Catalogno.<br>~~ee~~|
|---|---|---|
|Enclosed fuseclip|2 (51)|A3354710*<br>A3354730*|
|Open fuseclip<br>Springloaded open fuseclip|3 (76)|1A0065<br>9078A67G04|
* For single barrel applications only. Not sold in pairs.
Data sheet no. 10350
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-3
## **7 — Medium voltage fuses**
## CLE and JCX
**==> picture [537 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in (mm)<br>Amps Length A Diameter B Clip centers C IR RMS Sym. (kA) No. of barrels Installation location Catalog no.<br>**----- End of picture text -----**<br>
|Amps<br>Dimensions — in (mm)<br>Length A<br>Diameter B<br>Clipcenters C|IR RMS Sym. (kA)|No. of barrels|Installation location|Catalogno.|
|---|---|---|---|---|
|1<br>9.2 (234)<br>2 (51)<br>7 (178)<br>2<br>3<br>5<br>7<br>10<br>10<br>10.9 (277)<br>3 (76)|40|1|Indoor/outdoor|JCX-1E|
|||||JCX-2E|
|||||JCX-3E|
|||||JCX-5E|
|||||JCX-7E|
|||||JCX-10E|
||50||Indoor|2CLE-10E|
|15<br>9.5 (241)<br>2 (51)<br>8.1 (206)<br>20<br>25||||2CLE-15E|
|||||2CLE-20E|
|||||2CLE-25E|
|30<br>10.9 (277)<br>3 (76)<br>7 (178)<br>40<br>50<br>65<br>80<br>100<br>125<br>150<br>200<br>225<br>250*<br>300*<br>350**<br>400**<br>450**||||2CLE-30E|
|||||2CLE-40E|
|||||2CLE-50E|
|||||2CLE-65E|
|||||2CLE-80E|
|||||2CLE-100E|
|||||2CLE-125E|
|||||2CLE-150E|
|||||2CLE-200E|
|||||2CLE-225E|
|||2||2CLE-250E|
|||||2CLE-300E|
|||||2CLE-350X|
|||||2CLE-400X|
|||||2CLE-450X|
* 250 and 300 amp ratings may also be applied at 280 and 325 amps respectively, but fuses will no longer be complaint with ANSI E rating criteria. ** Does not comply with ANSI C37.46 for “E” rating.
Data sheet no. 10350
Eaton.com/bussmannseries
7-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## 5.5 kV E-Rated medium voltage ferrule fuses
## Catalog symbols
- General purpose
- 5CLE-_E-D (10-25 A)
- 5CLE-_E (10-1350 A)
- 5HLE-_E (10-450 A)
- JCY-_E (1-25 A)
- Full range (per ANSI C37.40)
- MV055F_ (10-450 A)
## Ratings*
Dimensions — in (mm)
**==> picture [262 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>\ o y B<br>J<br>HON<br>3.31<br>(84.1)<br> B<br>P<br>._— A<br>**----- End of picture text -----**<br>
- Volts 5.5 kV
- Amps 1 to 450 A
- Interrupting ratings 40 to 63 kA RMS Sym.
- See catalog number tables for voltages, ampacities and interrupting ratings by catalog number.
Agency information
- E-Rated fuses meet the performance characteristics of ANSI C37.46
- UL Listed, Guide JEEG, File E240398. See catalog numbers.
## Recommended fuseclips
|Description|Fuse dia. — in (mm)|Catalogno.|
|---|---|---|
|Enclosed fuseclip<br>Open fuseclip|2 (51)<br>A3354710*<br>3 (76)<br>A3354730*<br>1A0065<br>~~——~~||
|Springloaded open fuseclip||9078A67G04|
- For single barrel applications only. Not sold in pairs.
## Recommended CLE and HLE holders
|||||||Catalogno.||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|Amps|Fuse mounting<br>type|BIL<br>(kV)|Approx. Dimensions — in (mm)<br>Diameter<br>A<br>Clip center<br>B||rox. Dimensions — in (mm)<br>Length C|Mounting*<br>Porcelain<br>insulator|Glass-polyester<br>insulator|Live parts<br>(with end<br>fittings)|End fittings<br>(disconnect<br>only)|||
|CLE<br>10E-D–25E-D<br>30E–250E<br>Single barrel<br>15E–25E<br>Single barrel|Non-disconnect<br>Disconnect†<br>Non-disconnect<br>Disconnect†|60|3.0 (76.2)<br>2.0 (50.8)|14.0 (355.6)<br>11.5 (292.1)|17.9 (454.7)<br>12.9 (327.7)|5CLE-PNM-D<br>5CLE-PDM-D<br>5CLE-PNM-C<br>5CLE-PDM-C|5CLE-GNM-D<br>5CLE-GDM-D<br>5CLE-GNM-C<br>5CLE-GDM-C|CLE-NL-D<br>CLE-DL-D<br>CLE-NL-C<br>CLE-DL-C|—<br>CLE-DF-D<br>—<br>CLE-DF-C|Medium voltage|fuses|
|300E–450E<br>Double barrel|Non-disconnect<br>Disconnect†||3.0 (76.2)|14.0 (355.6)|17.9 (454.7)|5CLE-PNM-E<br>5CLE-PDM-E|5CLE-GNM-E<br>5CLE-GDM-E|CLE-NL-E<br>CLE-DL-E|—<br>CLE-DF-E|||
|600E and 750E<br>Double barrel|Consult factory|||||||||||
|1100E and<br>1350E<br>Four barrel|Consult factory|—|4.0 (101.6)|N/A|N/A|—|—|—|—|||
|HLE||||||||||||
|10E-D–250E|Non-disconnect|||||5HLE-PNM-D|5HLE-GNM-D|CLE-NL-D|—|||
|Single barrel|Disconnect|||||5HLE-PDM-D|5HLE-GDM-D|CLE-DL-D|CLE-DF-D|||
|300E–450E|Non-disconnect|60|3.0 (76.2)|12.0 (304.8)|15.9 (403.9)|5HLE-PNM-E|5HLE-GNM-E|CLE-NL-E|—|||
|Double barrel|Disconnect|||||5HLE-PDM-E|5HLE-GDM-E|CLE-DL-E|CLE-DF-E|||
- Including live parts and end fittings, end fittings supplied only when required.
- Disconnect mountings provide a means for fuse extraction only. Do not use a disconnect mounting for load switching or fuse removal while energized.
Data sheet no. 10351
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-5
## **7 — Medium voltage fuses**
CLE, HLE and JCY general purpose
**==> picture [538 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in (mm) IR RMS Sym. Installation<br>Amps Length A Diameter B Clip centers C (kA) No. of barrels location Catalog no.<br>**----- End of picture text -----**<br>
|Amps<br>Dimensions — in (mm)<br>Length A<br>Diameter B|IR RMS Sym.<br>(kA)<br>Clipcenters C|No. of barrels|Installation<br>location|Catalogno.|
|---|---|---|---|---|
|1<br>11.2 (284)<br>2 (51)<br>2<br>3<br>5<br>7<br>10|9 (229)<br>40|1|Indoor/outdoor|JCY-1E|
|||||JCY-2E|
|||||JCY-3E|
|||||JCY-5E|
|||||JCY-7E|
|||||JCY-10E|
|10<br>17.9 (455)<br>3 (76)<br>10<br>15.9 (404)|14 (356)<br>63<br>12 (305)|||5CLE-10E-D|
|||||5HLE-10E|
|15<br>11.2 (284)<br>2 (51)<br>15<br>12.9 (328)|9 (229)<br>40|||JCY-15E|
||11.5 (292)<br>50||Indoor|5CLE-15E*|
|15<br>17.9 (455)<br>3 (76)<br>15<br>15.9 (404)|14 (356)<br>63<br>12 (305)||Indoor/outdoor|5CLE-15E-D|
|||||5HLE-15E|
|20<br>11.2 (284)<br>2 (51)<br>20<br>12.9 (328)|9 (229)<br>40|||JCY-20E|
||11.5 (292)<br>50||Indoor|5CLE-20E*|
|20<br>17.9 (455)<br>3 (76)<br>20<br>15.9 (404)|14 (356)<br>63<br>12 (305)||Indoor/outdoor|5CLE-20E-D|
|||||5HLE-20E|
|25<br>11.2 (284)<br>2 (51)<br>2 (51)<br>25<br>12.9 (328)|9 (229)<br>40|||JCY-25E|
||11.5 (292)<br>50||Indoor|5CLE-25E*|
|25<br>17.9 (455)<br>3 (76)<br>25<br>15.9 (404)<br>30<br>17.9 (455)<br>30<br>15.9 (404)<br>40<br>17.9 (455)<br>40<br>15.9 (404)<br>50<br>17.9 (455)<br>50<br>15.9 (404)<br>65<br>17.9 (455)<br>65<br>15.9 (404)<br>80<br>17.9 (455)<br>80<br>15.9 (404)<br>100<br>17.9 (455)<br>100<br>15.9 (404)<br>125<br>17.9 (455)<br>125<br>15.9 (404)<br>150<br>17.9 (455)<br>150<br>15.9 (404)<br>175<br>17.9 (455)<br>175<br>15.9 (404)<br>200<br>17.9 (455)<br>200<br>15.9 (404)<br>250<br>17.9 (455)<br>250<br>15.9 (404)<br>300<br>17.9 (455)<br>300<br>15.9 (404)<br>350<br>17.9 (455)<br>350<br>15.9 (404)<br>400<br>17.9 (455)<br>400<br>15.9 (404)<br>450<br>17.9 (455)<br>450<br>15.9 (404)|14 (356)<br>63<br>12 (305)<br>14 (356)<br>12 (305)||Indoor/outdoor|5CLE-25E-D|
|||||5HLE-25E|
|||||5CLE-30E|
|||||5HLE-30E|
||14 (356)<br>65<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)<br>14 (356)<br>12 (305)|||5CLE-40E†|
|||||5HLE-40E†|
|||||5CLE-50E†|
|||||5HLE-50E†|
|||||5CLE-65E†|
|||||5HLE-65E†|
|||||5CLE-80E†|
|||||5HLE-80E†|
|||||5CLE-100E†|
|||||5HLE-100E†|
|||||5CLE-125E†|
|||||5HLE-125E†|
|||||5CLE-150E†|
|||||5HLE-150E†|
|||||5CLE-175E†|
|||||5HLE-175E†|
|||||5CLE-200E†|
|||||5HLE-200E†|
|||||5CLE-250E†|
|||||5HLE-250E†|
|||2||5CLE-300E†|
|||||5HLE-300E†|
|||||5CLE-350E†|
|||||5HLE-350E†|
|||||5CLE-400E†|
|||||5HLE-400E†|
|||||5CLE-450E†|
|||||5HLE-450E†|
* Fuses conform to dimensional standards established by Westinghouse.
† UL Listed, Guide JEEG, File E240398.
Data sheet no. 10351
Eaton.com/bussmannseries
7-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
MV055 full range
**==> picture [536 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in (mm)<br>Amps Length A Diameter B Clip centers C IR RMS Sym. (kA) No. of Barrels Installation location Catalog no.<br>**----- End of picture text -----**<br>
|Amps<br>Length A|IR RMS Sym. (kA)<br>Diameter B<br>Clipcenters C|No. of Barrels<br>Installation location|Catalogno.|
|---|---|---|---|
|5<br>15.7 (399)<br>7<br>10<br>10<br>15<br>15<br>20<br>20<br>25<br>25<br>30<br>30<br>40<br>40<br>50<br>50<br>65<br>65<br>80<br>100<br>125<br>150<br>175<br>200<br>250<br>300<br>350<br>400<br>450|2 (51)<br>12 (305)<br>50<br>3 (76)<br>2 (51)<br>3 (76)<br>2 (51)<br>3 (76)<br>2 (51)<br>3 (76)<br>2 (51)<br>3 (76)<br>2 (51)<br>3 (76)<br>2 (51)<br>3 (76)<br>2 (51)<br>3 (76)|1<br>Indoor<br>2|MV055F1CAX5E|
||||MV055F1CAX7E|
||||MV055F1CAX10E|
||||MV055F1DAX10E|
||||MV055F1CAX15E|
||||MV055F1DAX15E|
||||MV055F1CAX20E|
||||MV055F1DAX20E|
||||MV055F1CAX25E|
||||MV055F1DAX25E|
||||MV055F1CAX30E|
||||MV055F1DAX30E|
||||MV055F1CAX40E|
||||MV055F1DAX40E|
||||MV055F1CAX50E|
||||MV055F1DAX50E|
||||MV055F1CAX65E|
||||MV055F1DAX65E|
||||MV055F1DAX80E|
||||MV055F1DAX100E|
||||MV055F1DAX125E|
||||MV055F1DAX150E|
||||MV055F1DAX175E|
||||MV055F1DAX200E|
||||MV055F2DAX250E|
||||MV055F2DAX300E|
||||MV055F2DAX350E|
||||MV055F2DAX400E|
||||MV055F2DAX450E|
## Recommended MV055 fuseclips
**==> picture [263 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
Description Fuse dia. — in (mm) Catalog no.<br>**----- End of picture text -----**<br>
|Enclosed fuseclip|2 (51)|A3354710*|
|---|---|---|
||3 (76)|A3354730*|
|Open fuseclip||1A0065|
|Springloaded open fuseclip||9078A67G04|
* For single barrel applications only. Not sold in pairs.
Data sheet no. 10351
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-7
**7 — Medium voltage fuses**
## 5.5 kV ~~E-Rated medium voltage~~ specialty mount fuses
## Catalog symbols
- 5AHLE- ~~_E (for Eaton~~ AMPGARD motor starting assemblies)
- 5BHLE-_E / 5BHCL-_E (bolt-on version)
- 5CLE-_ ~~E~~
- 5HCL-_E (clip-lock version)
Ratings*
- Volts 5.5 kV
- Amps 10 to 1350 A
- Interru ~~p~~ ting ratings 31 to 63 kA RMS Sym.
- See catalog number tables for voltages, ampacities and interrupting ratings by catalog n ~~u~~ mber.
Agency information
## HCL clip-lock
**==> picture [257 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>Indicator<br>0.5 (12.7)<br>0.25<br>(6.4)<br>4.31 (109.5)<br>1.25 1.25<br>(31.8) (31.8) B<br>7.94 (201.7)<br>**----- End of picture text -----**<br>
- E-Rated fuses meet the performanc ~~e~~ characteristics of ANSI C37.46
Recommended live parts for clip-lock fuses
- Catalog number HCL-NL-1
Dimensio ~~n~~ s — in (mm)
BHLE bolt-on
**==> picture [241 x 204] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.12<br>(53.8)<br>B C<br> A<br>Indicator to be<br>located here<br>3.31<br>(84.1)<br>B 2.12 C<br>(53.8) A<br>**----- End of picture text -----**<br>
## CLE four-barrel bolt-on
**==> picture [253 x 187] intentionally omitted <==**
**----- Start of picture text -----**<br>
16.0<br>10.18<br>1.19<br>20.0<br>**----- End of picture text -----**<br>
**==> picture [210 x 50] intentionally omitted <==**
Note: 1100E and 1350E fuses require two double barrel fuses (4 total barrels) customer to parallel.
Data sheet no. 10351
Eaton.com/bussmannseries
7-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
## **Medium voltage fuses — 7**
AHLE for Eaton AMPGARD motor starting assemblies
|AHLE for Eaton AMPGARD motor starting assemblies|AHLE for Eaton AMPGARD motor starting assemblies|||||
|---|---|---|---|---|---|
|Amps<br>IR RMS Sym. (kA)||No. of barrels||Catalogno.|Medium voltage<br>fuses<br>Catalogno.<br>5HCL-10E<br>5HCL-15E<br>5HCL-20E<br>5HCL-25E<br>5HCL-30E<br>5HCL-40E†<br>5HCL-50E†<br>5HCL-65E†<br>5HCL-80E†<br>5HCL-100E†<br>5HCL-125E†<br>5HCL-150E†<br>5HCL-200E†<br>5HCL-250E†<br>5HCL-300E†<br>5HCL-400E†<br>5HCL-450E†<br>5HCL-500E|
|10<br>65<br>15<br>20<br>25<br>30<br>40<br>50<br>65<br>80<br>100<br>125<br>150<br>175<br>200<br>250<br>300<br>350<br>400<br>450||1||5AHLE-10E||
|||||5AHLE-15E||
|||||5AHLE-20E||
|||||5AHLE-25E||
|||||5AHLE-30E||
|||||5AHLE-40E†||
|||||5AHLE-50E†||
|||||5AHLE-65E†||
|||||5AHLE-80E†||
|||||5AHLE-100E†||
|||||5AHLE-125E†||
|||||5AHLE-150E†||
|||||5AHLE-175E†||
|||||5AHLE-200E†||
|||||5AHLE-250E†||
|||2||5AHLE-300E†||
|||||5AHLE-350E†||
|||||5AHLE-400E†||
|||||5AHLE-450E†||
|† UL Listed, Guide JEEG, File E240398.<br>HCL clip-lock versions||||||
|Amps|Dimensions — in (mm)||No. of barrels|Installation<br>location||
|10|16.8 (427)<br>3 (76)<br>N/A<br>65<br>22.8 (579)||1|Indoor||
|15||||||
|20||||||
|25||||||
|30||||||
|40||||||
|50||||||
|65||||||
|80||||||
|100||||||
|125||||||
|150||||||
|200||||||
|250||||||
|300|||2|||
|400||||||
|450||||||
|500||||||
|600|||||5HCL-600E|
† UL Listed, Guide JEEG, File E240398.
Data sheet no. 10351
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-9
## **7 — Medium voltage fuses**
CLE, BHLE and BHCL bolt-on versions
**==> picture [537 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in (mm) IR RMS Sym. Installation<br>Amps Length A Diameter B Hole centers C (kA) No. of barrels location Catalog no.<br>**----- End of picture text -----**<br>
|Amps<br>Dimensions — in (mm)<br>Length A<br>Diameter B|IR RMS Sym.<br>(kA)<br>Hole centers C|No. of barrels<br>Installation<br>location|Catalogno.|
|---|---|---|---|
|10<br>19.2 (488)<br>3 (76)<br>15<br>20<br>25<br>30<br>40<br>50<br>65<br>80<br>100<br>125<br>150<br>175<br>200<br>200<br>25.1 (637)<br>250<br>19.2 (488)<br>250<br>25.1 (637)<br>300<br>19.2 (488)<br>300<br>25.1 (637)<br>350<br>19.2 (488)<br>400<br>400<br>25.1 (637)<br>450<br>19.2 (488)<br>450<br>25.1 (637)<br>500<br>600|17.9 (455)<br>65<br>23.7 (602)<br>17.9 (455)<br>23.7 (602)<br>17.9 (455)<br>23.7 (602)<br>17.9 (455)<br>23.7 (602)<br>17.9 (455)<br>23.7 (602)|1<br>Indoor<br>2<br>3<br>2<br>3<br>4|5BHLE-10E|
||||5BHLE-15E|
||||5BHLE-20E|
||||5BHLE-25E|
||||5BHLE-30E|
||||5BHLE-40E†|
||||5BHLE-50E†|
||||5BHLE-65E†|
||||5BHLE-80E†|
||||5BHLE-100E†|
||||5BHLE-125E†|
||||5BHLE-150E†|
||||5BHLE-175E†|
||||5BHLE-200E†|
||||5BHCL-200E|
||||5BHLE-250E†|
||||5BHCL-250E|
||||5BHLE-300E†|
||||5BHCL-300E|
||||5BHLE-350E†|
||||5BHLE-400E†|
||||5BHCL-400E|
||||5BHLE-450E†|
||||5BHCL-450E|
||||5BHCL-500E|
||||5BHCL-600E|
|600<br>28.9 (734)<br>4 (102)|18.4 (467)<br>40||5CLE-600E|
|750<br>25.1 (637)<br>3 (76)|23.7 (602)<br>63||5BHCL-750E|
|750<br>28.9 (734)<br>4 (102)|18.4 (467)<br>40||5CLE-750E|
|900<br>25.1 (637)<br>3 (76)|23.7 (602)<br>63||5BHCL-900E|
|1100<br>19.8 (503)<br>4 (102)<br>1350|18.4 (467)<br>31||5CLE-1100E|
||||5CLE-1350E|
† UL Listed, Guide JEEG, File E240398.
Data sheet no. 10351
Eaton.com/bussmannseries
7-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## 8.3 kV E-Rated medium voltage ferrule fuses
## Catalog symbols
- 8CLE-_E-D (10-25 A)
- 8CLE-_E (10-350 A)
- 8HLE-_E (10-350 A)
## Ratings*
- Volts 8.3 kV
- Amps 10 to 350 A
- Interrupting rating 50 kA RMS Sym.
- See catalog number tables for voltages, ampacities and interrupting ratings by catalog number.
## Dimensions — in (mm)
C B \ ~~pope PQ)~~ a) 3.31 aCWK J (84.1) B pp) ~~___~~ A
## Agency information
- E-Rated fuses meet the performance characteristics of ANSI C37.46
Recommended fuseclips
|Description<br>Fuse dia. — in (mm)<br>Catalogno.<br>~~ee~~|Description<br>Fuse dia. — in (mm)<br>Catalogno.<br>~~ee~~|Description<br>Fuse dia. — in (mm)<br>Catalogno.<br>~~ee~~|
|---|---|---|
|Enclosed fuseclip|2 (51)|A3354710*<br>A3354730*|
|Open fuseclip|3 (76)|1A0065|
|Springloaded open fuseclip||9078A67G04|
- For single barrel applications only. Not sold in pairs.
## Recommended fuse holders
|||||||Catalogno.||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|Amps|Fuse mounting<br>type|BIL<br>(kV)|Approx. dimensions — in (mm)<br>Diameter A<br>Clipcenter B<br>Length C|||Mounting*<br>Porcelain<br>insulator|Glass-polyester<br>insulator|Live parts<br>(with end<br>fittings)|End fittings<br>(disconnect<br>only)|||
|CLE||||||||||||
|10E-D–25E-D<br>30E–175E<br>Single barrel|Non-disconnect<br>Disconnect†||3.0 (76)||17.9 (455)|8CLE-PNM-D<br>8CLE-PDM-D|8CLE-GNM-D<br>8CLE-GDM-D|CLE-NL-D<br>CLE-DL-D|—<br>CLE-DF-D|||
|15E–25E<br>Single Barrel|Non-disconnect<br>Disconnect†|75|2.0 (51)|14 (356)|15.5 (394)|8CLE-PNM-C<br>8CLE-PDM-C|8CLE-GNM-C<br>8CLE-GDM-C|CLE-NL-C<br>CLE-DL-C|—<br>CLE-DF-C|||
|200E–350E<br>Double barrel<br>HLE<br>10E-175E<br>Single barrel<br>200E–350E|Non-disconnect<br>Disconnect<br>Non-disconnect<br>Disconnect†<br>Non-disconnect|75|3.0 (76)<br>3.0 (76)|12 (305)|17.9 (455)<br>15.9 (404)|8CLE-PNM-E<br>8CLE-PDM-E<br>8HLE-PNM-D<br>8HLE-PDM-D<br>8HLE-PNM-E|8CLE-GNM-E<br>8CLE-GDM-E<br>8HLE-GNM-D<br>8HLE-GDM-D<br>8HLE-GNM-E|CLE-NL-E<br>CLE-DL-E<br>CLE-NL-D<br>CLE-DL-D<br>CLE-NL-E|—<br>CLE-DF-E<br>—<br>CLE-DF-D<br>—|Medium voltage|fuses|
|Double barrel|Disconnect†|||||8HLE-PDM-E|8HLE-GDM-E|CLE-DL-E|CLE-DF-E|||
- Including live parts and end fittings, end fittings supplied only when required.
- Disconnect mountings provide a means for fuse extraction only. Do not use a disconnect mounting for load switching or fuse removal while energized.
Data sheet no. 10352
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-11
## **7 — Medium voltage fuses**
CLE and HLE Type fuses
|Amps|Dimensions — in (mm)<br>IR RMS Sym. (kA)<br>Length A<br>Diameter B<br>Clipcenters C|No. of barrels|Installation<br>location|Catalogno.|
|---|---|---|---|---|
|CLE Long construction (Westinghouse)|||||
|10<br>17.9 (455)<br>3 (76)<br>14 (356)<br>50<br>15<br>15.5 (394)<br>2 (51)<br>15<br>17.9 (455)<br>3 (76)<br>20<br>15.5 (394)<br>2 (51)<br>20<br>17.9 (455)<br>3 (76)<br>25<br>15.5 (394)<br>2 (51)<br>25<br>17.9 (455)<br>3 (76)<br>30<br>40<br>50<br>65<br>80<br>100<br>125<br>150<br>175<br>200<br>250<br>300<br>350||1|Indoor/outdoor|8CLE-10E-D|
||||Indoor|8CLE-15E*|
||||Indoor/outdoor|8CLE-15E-D|
||||Indoor|8CLE-20E*|
||||Indoor/outdoor|8CLE-20E-D|
||||Indoor|8CLE-25E*|
||||Indoor/outdoor|8CLE-25E-D|
|||||8CLE-30E|
|||||8CLE-40E|
|||||8CLE-50E|
|||||8CLE-65E|
|||||8CLE-80E|
|||||8CLE-100E|
|||||8CLE-125E|
|||||8CLE-150E|
|||||8CLE-175E|
|||2||8CLE-200E|
|||||8CLE-250E|
|||||8CLE-300E|
|||||8CLE-350E|
|HLE Short construction|||||
|10<br>15.9 (404)<br>3 (76)<br>12 (305)<br>50<br>15<br>20<br>25<br>30<br>40<br>50<br>65<br>80<br>100<br>125<br>150<br>175<br>200<br>250<br>300<br>350||1|Indoor/outdoor|8HLE-10E|
|||||8HLE-15E|
|||||8HLE-20E|
|||||8HLE-25E|
|||||8HLE-30E|
|||||8HLE-40E|
|||||8HLE-50E|
|||||8HLE-65E|
|||||8HLE-80E|
|||||8HLE-100E|
|||||8HLE-125E|
|||||8HLE-150E|
|||||8HLE-175E|
|||2||8HLE-200E|
|||||8HLE-250E|
|||||8HLE-300E|
|||||8HLE-350E|
* Fuses conform to dimensional standards established by Westinghouse.
Data sheet no. 10352
Eaton.com/bussmannseries
7-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## 8.3 kV E-Rated medium voltage specialty mount fuses
Catalog symbols
- 8AHLE-_E (special dimension fuses for use with 7.2 kV rated, 800 amp AMPGARD motor starting assemblies)
- 8BHLE-_E (bolt-on version)
- 8HCL-_E (clip-lock version)
Ratings*
- Volts 8.3 kV
- Amps 10 to 350 A
- Interrupting rating 50 kA RMS Sym.
- See catalog number tables for voltages, ampacities and interrupting ratings by catalog number.
## Agency information
- E-Rated fuses meet the performance characteristics of ANSI C37.46
Recommended live parts for clip-lock fuses
- Catalog number HCL-NL-1
Dimensions for BHLE — in (mm)
**==> picture [254 x 215] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.12<br>(53.8)<br>B C<br> A<br>Indicator to be<br>located here<br>3.31<br>(84.1)<br>B 2.12 C<br>(53.8) A<br>**----- End of picture text -----**<br>
Dimensions for HCL — in (mm)
**==> picture [255 x 171] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>Indicator<br>0.5 (12.7)<br>0.25<br>(6.4)<br>4.31 (109.5)<br>1.25 1.25<br>(31.8) (31.8) B<br>7.94 (201.7)<br>**----- End of picture text -----**<br>
Data sheet no. 10352
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-13
**7 — Medium voltage fuses**
## AHLE Type fuses
Special dimension fuses for use with 7.2 kV rated, 800 amp AMPGARD motor starting assemblies.
|Amps<br>IR RMS Sym. (kA)|Amps<br>IR RMS Sym. (kA)|No. of barrels|No. of barrels|Catalogno.||
|---|---|---|---|---|---|
|10<br>50<br>15<br>20<br>25<br>30<br>40<br>50<br>65<br>80<br>100<br>125<br>150<br>175<br>200<br>250<br>300<br>350||1||8AHLE-10E||
|||||8AHLE-15E||
|||||8AHLE-20E||
|||||8AHLE-25E||
|||||8AHLE-30E||
|||||8AHLE-40E||
|||||8AHLE-50E||
|||||8AHLE-65E||
|||||8AHLE-80E||
|||||8AHLE-100E||
|||||8AHLE-125E||
|||||8AHLE-150E||
|||||8AHLE-175E||
|||2||8AHLE-200E||
|||||8AHLE-250E||
|||||8AHLE-300E||
|||||8AHLE-350E||
|BHLE bolt-on versions||||||
|Amps|Dimensions — in (mm)||No. of barrels|Installation<br>location|Catalogno.|
|10|19.25 (488.9)<br>3 (76.2)<br>17.88 (454.2)<br>50||1|Indoor|8BHLE-10E|
|15|||||8BHLE-15E|
|20|||||8BHLE-20E|
|25|||||8BHLE-25E|
|30|||||8BHLE-30E|
|40|||||8BHLE-40E|
|50|||||8BHLE-50E|
|65|||||8BHLE-65E|
|80|||||8BHLE-80E|
|100|||||8BHLE-100E|
|125|||||8BHLE-125E|
|150|||||8BHLE-150E|
|175|||||8BHLE-175E|
|200|||2||8BHLE-200E|
|250|||||8BHLE-250E|
|300|||||8BHLE-300E|
|350|||||8BHLE-350E|
## HCL Clip lock versions
**==> picture [537 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in (mm) Installation<br>Amps Overall length Diameter Hole centers IR RMS Sym. (kA) No. of barrels location Catalog no.<br>**----- End of picture text -----**<br>
|Amps<br>Dimensions — in (mm)<br>IR RMS Sym. (kA)<br>Overall length<br>Diameter<br>Hole centers|No. of barrels<br>Installation<br>location|Catalogno.|
|---|---|---|
|65<br>22.5 (571.5)<br>3 (76.2)<br>N/A<br>50<br>80<br>100<br>125<br>150<br>175<br>200<br>250<br>300<br>350|1<br>Indoor/outdoor<br>2|8HCL-65E|
|||8HCL-80E|
|||8HCL-100E|
|||8HCL-125E|
|||8HCL-150E|
|||8HCL-175E|
|||8HCL-200E|
|||8HCL-250E|
|||8HCL-300E|
|||8HCL-350E|
Data sheet no. 10352
Eaton.com/bussmannseries
7-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## 15.5 kV E-Rated medium voltage ferrule fuses
## Catalog symbols
- General purpose
- 15CLE-_E-D (long construction, 10-25 A)
- 15CLE-_E (long construction, 15-300 A)
- 15HLE-_E (short construction, 10-250 A)
- 15LHLE-_E (intermediate construction, 65-300 A)
- Full range (per ANSI C37.40)
- MV155F_
## Ratings*
- Volts 15.5 kV
**==> picture [262 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br> B<br>LD<br>=<br>|<br>3.31 FIO<br>(84.1)<br> B<br>ree IO<br>-_——___ A ______ +<br>**----- End of picture text -----**<br>
- Amps 10 to 300 A
- Interrupting ratings 31.5 to 63 kA RMS Sym.
- See catalog number tables for voltages, ampacities and interrupting ratings by catalog number.
## Agency information
- E-Rated fuses meet the performance characteristics of ANSI C37.46
- UL Listed, Guide JEEG, File E240398. See catalog numbers.
## Recommended fuse holders
Dimensions — in (mm)
Recommended fuseclips
|Description<br>Fuse dia. — in (mm)<br>Catalogno.<br>~~ee~~|Description<br>Fuse dia. — in (mm)<br>Catalogno.<br>~~ee~~|Description<br>Fuse dia. — in (mm)<br>Catalogno.<br>~~ee~~|Description<br>Fuse dia. — in (mm)<br>Catalogno.<br>~~ee~~|
|---|---|---|---|
||Enclosed fuseclip|2 (51)|A3354710*<br>A3354730*|
||Open fuseclip|3 (76)|1A0065|
||Springloaded open fuseclip||9078A67G04|
- For single barrel applications only. Not sold in pairs.
|||||||Catalogno.|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Amps|Fuse mounting<br>type|BIL<br>(kV)|Approx. dimensions — in (mm)<br>Diameter<br>Clipcenter<br>Length|||Mounting*<br>Porcelain insulator|Glass-polyester<br>insulator|Live parts<br>(with end<br>fittings)|End fittings<br>(disconnect<br>only)||||
|CLE|||||||||||||
|15E–25E<br>Single barrel|Non-disconnect<br>Disconnect†|95<br>110<br>95<br>110|2 (51)||21.5 (546)|15CLE-PNM-C<br>15CLE-HPNM-C<br>15CLE-PDM-C<br>15CLE-HPDM-C|15CLE-GNM-C<br>—<br>15CLE-GDM-C<br>—|CLE-NL-C<br>CLE-NL-C<br>CLE-DL-C<br>CLE-DL-C|—<br>—<br>CLE-DF-C<br>CLE-DF-C||||
|10E-D–25E-D<br>30E–150E<br>Single barrel|Non-disconnect<br>Disconnect†|95<br>110<br>95<br>110|3 (76)|20 (508)|23.9 (607)|15CLE-PNM-D<br>15CLE-HPM-D<br>15CLE-PDM-D<br>15CLE-HPDM-D|15CLE-GNM-D<br>—<br>15CLE-GDM-D<br>—|CLE-NL-D<br>CLE-NL-D<br>CLE-DL-D<br>CLE-DL-D|—<br>—<br>CLE-DF-D<br>CLE-DF-D||||
|175E–300E<br>Double barrel<br>HLE<br>10E-125E<br>Single barrel<br>150E–250E|Non-disconnect<br>Disconnect†<br>Non-disconnect<br>Disconnect†<br>Non-disconnect|110<br>110<br>95<br>95<br>95|3 (76)|15 (381)|18.9 (480)|15CLE-PNM-E<br>15CLE-PDM-E<br>15HLE-PNM-D<br>15HLE-PDM-D<br>15HLE-PNM-E|—<br>—<br>15HLE-GNM-D<br>15HLE-GDM-D<br>—|CLE-NL-E<br>CLE-DL-E<br>CLE-NL-D<br>CLE-DL-D<br>CLE-NL-E|—<br>CLE-DF-E<br>—<br>CLE-DF-D<br>—<br>|||Medium voltage|fuses|
|Double barrel<br>Disconnect†<br>95<br>15HLE-PDM-E<br>—<br>CLE-DL-E<br>CLE-DF-E<br>LHLE<br>65E–150E<br>Non-disconnect<br>—<br>CLE-NL-D<br>—<br>~~ee~~|||||||||||||
|Single barrel<br>175E–300E|Disconnect†<br>Non-disconnect|—<br>—|3 (76)|18 (457)|20.53 (521)|Not available|Not available|CLE-DL-D<br>CLE-NL-E|CLE-DF-D<br>—||||
|Double barrel|Disconnect†|—||||||CLE-DL-E|CLE-DF-E||||
- Including live parts and end fittings, end fittings supplied only when required.
- Disconnect mountings provide a means for fuse extraction only. Do not use a disconnect mounting for load switching or fuse removal while energized.
Data sheet no. 10353
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-15
## **7 — Medium voltage fuses**
CLE, HLE and LHLE Type general purpose fuses
**==> picture [538 x 564] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in (mm) IR RMS Sym. Installation<br>Amps Length A Diameter B Clip centers C (kA) No. of barrels location Catalog no.<br>CLE Long construction<br>10 23.9 (607) 3 (76) 63 Indoor/outdoor 15CLE-10E-D<br>15 21.5 (546) 2 (51) 31.5 Indoor 15CLE-15E*<br>15 23.9 (607) 3 (76) 63 Indoor/outdoor 15CLE-15E-D<br>20 21.5 (546) 2 (51) 31.5 Indoor 15CLE-20E*<br>20 23.9 (607) 3 (76) 63 Indoor/outdoor 15CLE-20E-D<br>25 21.5 (546) 2 (51) 31.5 Indoor 15CLE-25E*<br>25 1 15CLE-25E-D<br>30 15CLE-30E<br>40 15CLE-40E [†]<br>50 20 (508) 15CLE-50E [†]<br>65 15CLE-65E [†]<br>80 15CLE-80E [†]<br>100 23.9 (607) 3 (76) 63 Indoor/outdoor 15CLE-100E [†]<br>125 15CLE-125E-D [†]<br>150 15CLE-150E-D [†]<br>175 15CLE-175E [†]<br>2<br>200 15CLE-200E [†]<br>250 15CLE-250E [†]<br>300 15CLE-300E [†]<br>HLE Short construction<br>10 15HLE-10E<br>15 15HLE-15E<br>20 15HLE-20E<br>25 15HLE-25E<br>30 1 15HLE-30E<br>40 15HLE-40E [†]<br>50 15HLE-50E [†]<br>65 18.9 (480) 3 (76) 15 (381) 63 Indoor/outdoor 15HLE-65E [†]<br>80 15HLE-80E [†]<br>100 15HLE-100E-D [†]<br>125 15HLE-125E-D [†]<br>150 15HLE-150E [†]<br>2<br>175 15HLE-175E [†]<br>200 15HLE-200E [†]<br>250 15HLE-250E [†]<br>LHLE<br>65 15LHLE-65E<br>80 15LHLE-80E<br>100 1 15LHLE-100E<br>125 15LHLE-125E<br>150 20.5 (521) 3 (76) 18 (457) 50 Indoor/outdoor 15LHLE-150E<br>175 15LHLE-175E<br>200 15LHLE-200E<br>2<br>250 15LHLE-250E<br>300 15LHLE-300E<br>**----- End of picture text -----**<br>
* Fuses conform to dimensional standards established by Westinghouse.
† UL Listed, Guide JEEG, File E240398.
Data sheet no. 10353
Eaton.com/bussmannseries
7-16
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## MV155F_ Full range
**==> picture [537 x 27] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in (mm) IR RMS Sym. Installation<br>Amps Length A Diameter B Clip centers C (kA) No. of barrels location Catalog no.<br>**----- End of picture text -----**<br>
|Amps<br>Dimensions — in<br>Length A<br>|(mm)<br>Diameter B|IR RMS Sym.<br>(kA)<br>Clipcenters C|No. of barrels<br>Installation<br>location|Catalogno.<br>|
|---|---|---|---|---|
|5<br>18.7 (475)<br>7<br>10<br>10<br>15<br>15<br>20<br>20<br>25<br>25<br>30<br>30<br>40<br>50<br>65|2 (51)|15 (381)<br>50<br>18 (457)<br>15 (381)<br>18 (457)<br>15 (381)<br>18 (457)<br>15 (381)<br>18 (457)<br>15 (381)<br>18 (457)<br>15 (381)<br>18 (457)<br>15 (381)<br>18 (457)|1<br>Indoor<br>2|MV155F1CBX5E|
|||||MV155F1CBX7E|
|||||MV155F1CBX10E|
||3 (76)|||MV155F1DBX10E|
||2 (51)|||MV155F1CBX15E|
||3 (76)|||MV155F1DBX15E|
||2 (51)|||MV155F1CBX20E|
||3 (76)|||MV155F1DBX20E|
||2 (51)|||MV155F1CBX25E|
||3 (76)|||MV155F1DBX25E|
||2 (51)|||MV155F1CBX30E|
||3 (76)|||MV155F1DBX30E|
|||||MV155F1DBX40E|
|||||MV155F1DBX50E|
|||||MV155F1DBX65E|
|65<br>21.7 (551)||||MV155F1DCX65E|
|80<br>18.7 (475)||||MV155F1DBX80E|
|80<br>21.7 (551)||||MV155F1DCX80E|
|100<br>18.7 (475)||||MV155F1DBX100E|
|100<br>21.7 (551)||||MV155F1DCX100E|
|125<br>18.7 (475)||||MV155F2DBX125E|
|125<br>21.7 (551)||||MV155F2DCX125E|
|150<br>18.7 (475)||||MV155F2DBX150E|
|150<br>21.7 (551)||||MV155F2DCX150E|
|175<br>18.7 (475)||||MV155F2DBX175E|
|175<br>21.7 (551)||||MV155F2DCX175E|
|200<br>18.7 (475)||||MV155F2DBX200E|
|200<br>21.7 (551)||||MV155F2DCX200E|
Data sheet no. 10353
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-17
**7 — Medium voltage fuses**
## 15.5 kV E-Rated medium voltage specialty mount fuses
Catalog symbols
- 15BHLE-_E (bolt-on version)
- 15HCL-_E (clip-lock version)
Ratings*
- Volts 15.5 kV
- Amps 10 to 400 A
- Interrupting ratings 50 to 63 kA RMS Sym.
- See catalog number tables for voltages, ampacities and interrupting ratings by catalog number.
Agency information
- E-Rated fuses meet the performance characteristics of ANSI C37.46
Recommended live parts for clip-lock fuses
- Catalog number HCL-NL-1
Dimensions — in (mm)
BHLE
HCL
**==> picture [534 x 214] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.12<br>(53.8)<br>A<br>Indicator<br>0.5 (12.7)<br>0.25<br>B C<br>(6.4)<br> A 4.31 (109.5)<br>1.25 1.25<br>Indicator to be (31.8) (31.8) B<br>located here<br>3.31<br>(84.1)<br>7.94 (201.7)<br>B 2.12 C<br>(53.8) A<br>**----- End of picture text -----**<br>
Data sheet no. 10353
Eaton.com/bussmannseries
7-18
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
BHCL, BHLE and HCL Type fuses
|Amps|Dimensions — in (mm)|IR RMS Sym.<br>(kA)<br>Hole centers C|No. of barrels|Installation<br>location|Catalogno.|
|---|---|---|---|---|---|
||Length A<br>Diameter B|||||
|BHCL and BHLE bolt-on||||||
|10<br>22.2 (563)<br>3 (76)<br>15<br>20<br>25<br>30<br>40<br>50<br>65<br>80<br>100<br>125<br>150<br>175<br>200<br>250<br>300<br>25.1 (637)<br>400||20.9 (531)<br>63|1|Indoor/outdoor|15BHLE-10E|
||||||15BHLE-15E|
||||||15BHLE-20E|
||||||15BHLE-25E|
||||||15BHLE-30E|
||||||15BHLE-40E†|
||||||15BHLE-50E†|
||||||15BHLE-65E†|
||||||15BHLE-80E†|
||||2||15BHLE-100E-D†|
||||||15BHLE-125E-D†|
||||||15BHLE-150E†|
||||||15BHLE-175E†|
||||||15BHLE-200E†|
||||||15BHLE-250E†|
|||23.7 (602)<br>50||Indoor|15BHCL-300E|
||||3|Indoor|15BHCL-400E|
|HCL clip-lock||||||
|10<br>22.8 (579)<br>3 (76)<br>15<br>20<br>25<br>30<br>40<br>50<br>65<br>80<br>100<br>125<br>150<br>175<br>200<br>250<br>300||N/A<br>63|1|Indoor|15HCL-10E|
||||||15HCL-15E|
||||||15HCL-20E|
||||||15HCL-25E|
||||||15HCL-30E|
||||||15HCL-40E†|
||||||15HCL-50E†|
||||||15HCL-65E†|
||||||15HCL-80E†|
||||||15HCL-100E†|
||||2||15HCL-125E-D†|
||||||15HCL-150E†|
||||||15HCL-175E†|
||||||15HCL-200E†|
||||||15HCL-250E†|
||||||15HCL-300E†|
† UL Listed, Guide JEEG, File E240398.
Data sheet no. 10353
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-19
**7 — Medium voltage fuses** ~~I~~ FC ce
## 5.5 to 38 kV E-Rated DIN medium voltage fuses
Bussmann series DIN dimensioned E-Rated medium voltage power fuses with striker for indoor use. Available in general purpose (5.5 to 17.5 kV) and full range (25.8 to 38 kV) versions.
## Ratings
- Volts 5.5 - 38 kV
- Amps 10 - 450 A
- Interrupting ratings 25 to 65 kA
## Agency information
- General purpose E-Rated per ANSI C37.46 (5.5 to 17.5 kV)
- Full range E-Rated per ANSI C37.40 (25.8 to 38 kV)
## Striker force
- 50 N (11 lbs)
Recommended fuseclips
See page 7-36 for dimensions.
|Amp range<br>Description<br>Catalog no.<br>~~ee~~|Amp range<br>Description<br>Catalog no.<br>~~ee~~|Amp range<br>Description<br>Catalog no.<br>~~ee~~|
|---|---|---|
|Up to 200 A|Enclosed fuseclip with wingnut<br>tensioner|A3354745*|
||Open fuseclip with spring tensioner|270303|
* Not sold in pairs.
## Features
- Cool running for lower watts loss
- 100% X-ray inspected to help assure fuse integrity
- Striker provides visual indication of fuse operation or a means to activate a remote monitoring system
## Typical applications
- Primary protection for medium voltage transformers and switch gear
- Protection of medium voltage feeder circuits
- Direct OEM replacement fuses for 600 A Square D HVLCC and HVL switches
Dimensions — in (mm)
**==> picture [429 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
Striker in operated position<br>(striker force 50 N/11 Lbs)<br>Diameter 1.77 0.59<br>(45) (15)<br>Cl] | ee<br>1.34 1.02<br>a Length e tsae (34) a (26)<br>See catalog numbers tables for diameter and length values.<br>**----- End of picture text -----**<br>
Data sheet no. 10638
Eaton.com/bussmannseries
7-20
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
**==> picture [537 x 659] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in (mm)<br>Catalog no. Amps Interrupting rating (Sym. kA) Length Diameter<br>General purpose versions<br>5.5 kV<br>55GDMSJ10E 10<br>55GDMSJ15E 15<br>55GDMSJ20E 20<br>55GDMSJ25E 25<br>55GDMSJ30E 30<br>55GDMSJ40E 40 17.4 (442) 2 (51)<br>55GDMSJ50E 50<br>55GDMSJ65E 65<br>55GDMSJ80E 80<br>55GDMSJ100E 100 65<br>55GDMSJ125E 125<br>55GFMSJ150E 150<br>55GFMSJ175E 175<br>55GFMSJ200E 200<br>55GFMSJ250E 250<br>17.4 (442) 3 (76)<br>55GFMSJ300E 300<br>55GFMSJ350E 350<br>55GFMSJ400E 400<br>55GFMSJ450E 450<br>15.5 kV<br>155GXQSJ175E 175<br>65 21.1 (537) 3.5 (89)<br>155GXQSJ200E 200<br>17.5 kV<br>175GDMSJ10E 10<br>175GDMSJ15E 15<br>175GDMSJ20E 20 17.4 (442) 2 (51)<br>175GDMSJ25E 25<br>175GDMSJ30E 30<br>175GFMSJ40E 40<br>65<br>175GFMSJ50E 50 17.4 (442) 3 (76)<br>175GFMSJ65E 65<br>175GXMSJ80E 80<br>17.4 (442) 3.5 (89)<br>175GXMSJ100E 100<br>175GXQSJ125E 125<br>21.1 (537) 3.5 (89)<br>175GXQSJ150E 150<br>Full range versions<br>25.8 kV<br>258GDQSJ10E 10<br>258GDQSJ15E 15<br>258GDQSJ20E 20 21.1 (537) 2 (51)<br>258GDQSJ25E 25<br>258GDQSJ30E 30<br>25<br>258GXQSJ40E 40<br>258GXQSJ50E 50 21.1 (537) 3.5 (89)<br>258GXQSJ65E 65<br>258GXZSJ80E 80<br>28.3 (718) 3.5 (89)<br>258GXZSJ100E 100<br>38 kV<br>38GFZSJ10E 10<br>38GFZSJ15E 15<br>38GFZSJ20E 20 25 28.3 (718) 3 (76)<br>38GFZSJ25E 25<br>38GFZSJ30E 30<br>**----- End of picture text -----**<br>
Data sheet no. 10638
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-21
**7 — Medium voltage fuses**
Dimensions — in (mm)
## 2.4 kV R-Rated fuses
## Catalog symbols/construction
- JCK-_R/Standard
- 2CLS-_R/Standard
- JCK-A-_R*/AMPGARD Hookeye
- 2ACLS-_R/AMPGARD Hookeye
- JCH-_R/Hermetically sealed AMPGARD
- 2HCLS-_R/Hermetically sealed AMPGARD
- JCK-B-_R/Bolt-on
|Construction<br>Amps<br>Dimension<br>A<br>B<br>C<br>D<br>Standard -<br>short<br>25-230A<br>10.8 (274)<br>3 (76)<br>3 (76)<br>—<br>390-450A<br>3.3 (84)<br>AMPGARD<br>Hookeye*<br>70-230A<br>—<br>390-450A<br>3.3 (84)<br>~~ee~~|
|---|
|Bolt-on<br>25-230A<br>19.2 (488)<br>17.9 (455)<br>—<br>390-450A<br>3.3 (84)|
- Includes hermetically sealed versions.
- 2BCLS-_R/Bolt-on
- For use in 400 amp AMPGARD motor starters.
## Standard and AMPGARD Hookeye
## Ratings
**==> picture [536 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
• Volts Gripping tab<br>for Hookeye<br> • 2.4 kV (nominal) D constructions only Indicator<br> • 2.54 kV (max design)<br>C<br> • Amps 25-450 A<br> • Interrupting ratings B A<br> • 50 kA Sym.<br> • 80 kA Asym.<br>Bolt-on<br>Agency information x a<br>**----- End of picture text -----**<br>
## Agency information
|Agency information<br>x|x~~a~~|Bolt-on<br>~~a~~|Bolt-on<br>~~a~~|Bolt-on<br>~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|~~a~~||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||R 0.23 [5.81] Typ.|||||
|• UL Recognized: Guide MSSS2, File E96676 (JCK-_R [2R-12R] and<br>JCK-A-_R [2R-12R])|||||E = 3 [76.2]<br>F = 2.5 [63.5]<br>G = 2.04 [51.81<br>E F G H I||||E F G H I|E F G H I||||||||
|Recommended fuseclips and holders for standard<br>constructions<br>Amps<br>Description<br>Catalogno.<br>Fuseclips<br>25-230A<br>3” Enclosed fuseclip*<br>A3354730<br>25-450A<br>3” Open fuseclip<br>1A0065<br>3” Springloaded open fuseclip<br>9078A67G04<br>~~en ~~<br>~~eee~~||3.0<br>[76.2]<br>2.12<br>[53.8]<br>D<br>B<br>A<br>3.0<br>[76.2]<br>H = 0.96 [24.4]<br>I = 0.5 [12.7]<br>Indicator<br>C<br> (OO~~LL~~<br>F~~S~~ EE||||||||||||||||
|Fuse holders||||||||||||||||||
|Non-disconnect holder,porcelain|2CLE-PNM-D|||||||||||||||||
|25-230A<br>Non-disconnect holder,glasspolyester|2CLE-GNM-D|||||||||||||||||
|Single barrel<br>Disconnect holder,porcelain|2CLE-PDM-D|||||||||||||||||
|Disconnect holder,glasspolyester|2CLE-GDM-E|||||||||||||||||
|Non-disconnect holder,porcelain|2CLE-PNM-E|||||||||||||||||
|390-450A<br>Double<br>Non-disconnect holder,glasspolyester|2CLE-GNM-E|||||||||||||||||
|barrel<br>Disconnect holder,porcelain|2CLE-PDM-E|||||||||||||||||
|Disconnect holder,glasspolyester|2CLE-GDM-E|||||||||||||||||
- Single barrel only, not sold in pairs.
2.4 kV R-Rated fuse catalog numbers
|Amps<br>"R"<br>Des.<br>Mountingstyle(minimum interruptingratingin amps)<br>No. of<br>barrels<br>Standard<br>Standard AMPGARD<br>Hermeticallysealed AMPGARD<br>Bolt-on<br>~~———————————————~~|Amps<br>"R"<br>Des.<br>Mountingstyle(minimum interruptingratingin amps)<br>No. of<br>barrels<br>Standard<br>Standard AMPGARD<br>Hermeticallysealed AMPGARD<br>Bolt-on<br>~~———————————————~~|Amps<br>"R"<br>Des.<br>Mountingstyle(minimum interruptingratingin amps)<br>No. of<br>barrels<br>Standard<br>Standard AMPGARD<br>Hermeticallysealed AMPGARD<br>Bolt-on<br>~~———————————————~~|Amps<br>"R"<br>Des.<br>Mountingstyle(minimum interruptingratingin amps)<br>No. of<br>barrels<br>Standard<br>Standard AMPGARD<br>Hermeticallysealed AMPGARD<br>Bolt-on<br>~~———————————————~~|Amps<br>"R"<br>Des.<br>Mountingstyle(minimum interruptingratingin amps)<br>No. of<br>barrels<br>Standard<br>Standard AMPGARD<br>Hermeticallysealed AMPGARD<br>Bolt-on<br>~~———————————————~~|Amps<br>"R"<br>Des.<br>Mountingstyle(minimum interruptingratingin amps)<br>No. of<br>barrels<br>Standard<br>Standard AMPGARD<br>Hermeticallysealed AMPGARD<br>Bolt-on<br>~~———————————————~~|Amps<br>"R"<br>Des.<br>Mountingstyle(minimum interruptingratingin amps)<br>No. of<br>barrels<br>Standard<br>Standard AMPGARD<br>Hermeticallysealed AMPGARD<br>Bolt-on<br>~~———————————————~~|Amps<br>"R"<br>Des.<br>Mountingstyle(minimum interruptingratingin amps)<br>No. of<br>barrels<br>Standard<br>Standard AMPGARD<br>Hermeticallysealed AMPGARD<br>Bolt-on<br>~~———————————————~~|Amps<br>"R"<br>Des.<br>Mountingstyle(minimum interruptingratingin amps)<br>No. of<br>barrels<br>Standard<br>Standard AMPGARD<br>Hermeticallysealed AMPGARD<br>Bolt-on<br>~~———————————————~~|Amps<br>"R"<br>Des.<br>Mountingstyle(minimum interruptingratingin amps)<br>No. of<br>barrels<br>Standard<br>Standard AMPGARD<br>Hermeticallysealed AMPGARD<br>Bolt-on<br>~~———————————————~~|Amps<br>"R"<br>Des.<br>Mountingstyle(minimum interruptingratingin amps)<br>No. of<br>barrels<br>Standard<br>Standard AMPGARD<br>Hermeticallysealed AMPGARD<br>Bolt-on<br>~~———————————————~~|
|---|---|---|---|---|---|---|---|---|---|---|
|25|—|—|2CLS-25*(100)|—|2ACLS-25*(90)|JCH-30*(90)|2HCLS-25*(90)|JCK-B-25*(90)|2BCLS-25*(90)||
|70|2R|JCK-2R(165)†|2CLS-2R(180)|JCK-A-2R(165)†|2ACLS-2R(180)|JCH-2R(180)|2HCLS-2R(180)|JCK-B-2R(180)|2BCLS-2R(180)||
|100|3R|JCK-3R(220)†|2CLS-3R(270)|JCK-A-3R(220)†|2ACLS-3R(270)|JCH-3R(270)|2HCLS-3R(270)|JCK-B-3R(270)|2BCLS-3R(270)||
|130<br>150|4R<br>5R|JCK-4R(320)†<br>JCK-5R(410)†|2CLS-4R(360)<br>2CLS-5R(450)|JCK-A-4R(320)†<br>JCK-A-5R(410)†|2ACLS-4R(360)<br>2ACLS-5R(450)|JCH-4R(360)<br>JCH-5R(450)|2HCLS-4R(360)<br>2HCLS-5R(450)|JCK-B-4R(360)<br>JCK-B-5R(450)|2BCLS-4R(360)<br>2BCLS-5R(450)|1|
|170|6R|JCK-6R(480)†|2CLS-6R(540)|JCK-A-6R(480)†|2ACLS-6R(540)|JCH-6R(540)|2HCLS-6R(540)|JCK-B-6R(540)|2BCLS-6R(540)||
|200|9R|JCK-9R(720)†|2CLS-200*(740)|JCK-A-9R(720)†|2ACLS-200*(740)|JCH-200*(740)|2HCLS-200*(740)|JCK-B-200*(740)|2BCLS-200*(740)||
|230|12R|JCK-12R(970)†|2CLS-230*(1080)|JCK-A-12R(970)†|2ACLS-230*(1080)|JCH-230*(1080)|2HCLS-230*(1080)|JCK-B-230*(1080)|2BCLS-230*(1080)||
|390<br>450|18R<br>24R|JCK-18R(1430)<br>JCK-24R(1880)|2CLS-390*(1500)<br>2CLS-450*(2200)|JCK-A-18R(1430)<br>JCK-A-24R(1880)|2ACLS-390*(1500)<br>2ACLS-450*(2200)|JCH-390*(1500)<br>JCH-450*(2200)|2HCLS-390*(1500)<br>2HCLS-450*(2200)|JCK-B-390*(1500)<br>JCK-B-450*(2200)|2BCLS-390*(1500)<br>2BCLS-450*(2200)|2|
- Does not comply with ANSI C37.46 for “R” rating.
- UL Recognized.
Data sheet no. 6001
Eaton.com/bussmannseries
7-22
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## 4.8 kV R-Rated fuses
## Catalog symbols/construction
- 5CLS-30 and 5CLS-_R/Standard - short (30 A, 2R-24R)
- JCL-_R/Standard - short (2R - 24R)
- 5LCLS-_R/Standard - long (2R - 24R)
- 5ACLS-30 and 5ACLS-_R/AMPGARD Hookeye* (30 A, 2R-24R)
- JCL-A-_R/AMPGARD Hookeye* (2R - 24R)
- 5HCLS-30 and 5HCLS-_R/Hermetically sealed AMPGARD Hookeye* (30 A, 2R-24R)
- 5BCLS-30 and 5BCLS-_R/Bolt-on (30 A, 2R-44R)
- JCL-B-_R/Bolt-on (2R-24R)
- 5MCLS-_R-_A and 5MCLS-_R-_B/Bolt-on GE Limitamp (2R- 24R)
- For use in 400 amp AMPGARD motor starters
## Ratings
- Volts
- 4.8 kV (nominal)
- 5.0 kV (max design)
- Amps 30-800 A
- Interrupting ratings
- 50 kA Sym.
- 80 kA Asym.
Agency information
- UL Recognized, Guide MSSS2
- File E96676: JCL-_R [2R-12R], JCL-A-_R [2R-12R], 5MCLS-_R-A [2R-24R], and 5MCLS-_R-B [2R-24R]
- File E60757: 5CLS-30, 5CLS-_R, 5ACLS-30, 5ACLS-_R [2R-24R], 5BCLS-30, and 5BCLS-_R [2R-24R]
Recommended fuseclips and holders for standard constructions
||BIL<br>||
|---|---|---|
|Amps<br>Fuseclips|Description<br>(kV)|Catalogno.|
|30-230A|3” Enclosed fuseclip*<br>—<br>3” Open fuseclip<br>”|A3354730|
|30-450A||1A0065<br>|
|3 Springloaded open fuseclip<br>Fuse holders for CLS/JCL/5HCLS||9078A67G04|
|30-230A<br>Single<br>barrel|Non-disconnect holder, porcelain<br>60<br>Non-disconnect holder, glasspolyester<br>Disconnect holder, porcelain<br>Disconnect holder, glasspolyester<br>Non-disconnect holder, porcelain<br>Non-disconnect holder, glasspolyester<br>Disconnect holder, porcelain<br>Disconnect holder, glasspolyester<br>f LCLS†|5HLE-PNM-D|
|||5HLE-GNM-D<br>5HLE-PDM-D<br>|
|390-450A<br>Double<br>barrel<br>F hld||5HLE-GDM-D<br>5HLE-PNM-E|
|||5HLE-GNM-E|
|||5HLE-PDM-E|
|||5HLE-GDM-E|
|use oer<br>70-230A<br>Single<br>barrel|or 5<br>Non-disconnect holder, porcelain<br>60<br>Non-disconnect holder, glasspolyester<br>Disconnect holder, porcelain<br>Disconnect holder, glasspolyester<br>Disconnect holderorcelain|5CLE-PNM-D|
|||5CLE-GNM-D<br>5CLE-PDM-D|
|||5CLE-GDM-D<br>8CLE-PDM-D|
||, p<br>75<br>Disconnect holder, glasspolyester|8CLE-GDM-D|
|390-450A<br>Double<br>Barrel|Disconnect holder, porcelain<br>60<br>Disconnect holder, glass polyester|5CLE-PDM-E|
|||5CLE-GDM-E|
## Dimensions — in (mm)
**==> picture [263 x 287] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimension<br>Construction Amp A B C D<br>30-230 —<br>Standard - short 15.6 (396)<br>390-450 3.3 (84)<br>70-230 —<br>Standard - long 17.8 (452) 3 (76)<br>390-450 3.3 (84)<br>3 (76)<br>AMPGARD 30-230 —<br>15.6 (396)<br>Hookeye* 390-450 3.3 (84)<br>30-230 —<br>Bolt-on 390-450 19.2 (488) 17.9 (455) 3.3 (84)<br>600-800 4 (101) 9 (229)<br>70-230 4.8 (122)<br>Limitamp (-A)<br>390-450 7.4 (188)<br>18.3 (465) 18.8 (478) 1.4 (36)<br>70-230 3.0 (76)<br>Limitamp (-B)<br>390-450 2.4 (61)<br>* Includes hermetically sealed versions.<br>Ferrule JCL, 5LCLS, 5CLS and AMPGARD Hookeye<br>Gripping tab<br>for Hookeye<br>D constructions only Indicator<br>C<br>B<br>A<br>**----- End of picture text -----**<br>
Bolt-on — 5BCLS-_ up to 24R
**==> picture [225 x 78] intentionally omitted <==**
**----- Start of picture text -----**<br>
R 0.23 [5.81] Typ.<br>E F G H I<br>E = 3 [76.2]<br>F = 2.5 [63.5]<br>G = 2.04 [51.81<br>H = 0.96 [24.4]<br>I = 0.5 [12.7]<br>D Indicator<br>C<br>2.12<br>[53.8]<br>B<br>[76.2]3.0 [76.2]3.0 A<br>**----- End of picture text -----**<br>
Bolt-on — 5MCLS-_R-A
**==> picture [243 x 252] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 SLOTS (0.38X0.5) 17.7 (striker not extended)<br> 0.25 C 16.5<br> 0.25 0.25<br> D<br> 7.75 3.1<br>Ø3.0 (REF) 2.25<br> 2.250 A<br> B 2 SLOTS<br>(.343 X .875)<br> C<br>Bolt-on — 5MCLS-_R-B<br> 17.7 (striker not extended)<br>Ø3.00 REF 0.25 0.25 16.5 0.25<br> 3.1<br> 7.01<br> D 2.25<br> 0.38<br> A<br> 2.25 B<br>2 SLOTS (0.38X0.5)<br>2 SLOTS<br>(0.343X0.875)<br> C C<br>**----- End of picture text -----**<br>
Bolt-on — 5MCLS-_R-B
- Single barrel only, not sold in pairs.
- ** Not available for standard - long constructions
† Not available for 390 to 450 amp ratings.
Data sheet no. 6001
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-23
## **7 — Medium voltage fuses**
## 4.8 kV R-Rated fuse catalog numbers
**==> picture [537 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ferrule constructions (min. interrupting rating in amps) No. of Bolt-on (min. interrupting rating in amps) No. of<br>Amps Short Short Long barrels Amps Regular Regular barrels<br>30 5CLS-30* (100)† — — 30 5BCLS-30* (100)† —<br>70 5CLS-2R (180)† JCL-2R (165)† 5LCLS-2R (180) 70 5BCLS-2R (180)† JCL-B-2R (165)<br>100 5CLS-3R (270)† JCL-3R (220)† 5LCLS-3R (270) 100 5BCLS-3R (270)† JCL-B-3R (220)<br>130 5CLS-4R (360)† JCL-4R (320)† 5LCLS-4R (360) 130 5BCLS-4R (360)† JCL-B-4R (320)<br>1 1<br>150 5CLS-5R (450)† JCL-5R (410)† 5LCLS-5R (450) 150 5BCLS-5R (450)† JCL-B-5R (410)<br>170 5CLS-6R (540)† JCL-6R (480)† 5LCLS-6R (540) 170 5BCLS-6R (540)† JCL-B-6R (480)<br>200 5CLS-9R (740)† JCL-9R (720)† 5LCLS-9R (740) 200 5BCLS-9R (740)† JCL-B-9R (720)<br>230 5CLS-12R (1080)† JCL-12R (970)† 5LCLS-12R (1080) 230 5BCLS-12R (1080)† JCL-B-12R (970)<br>390 5CLS-18R (1500)† JCL-18R (1430) 5LCLS-18R (1500) 390 5BCLS-18R (1500)† JCL-B-18R (1430)<br>2<br>450 5CLS-24R (2200)† JCL-24R (1880) 5LCLS-24R (2200) 450 5BCLS-24R (2200)† JCL-B-24R (1880)<br>* Does not comply with ANSI C37.46 for "R" rating. 600 5BCLS-32R (3000) — 2<br>† UL Recognized. 650 5BCLS-36R (3200) —<br>800 5BCLS-44R (3600) —<br>**----- End of picture text -----**<br>
|<br> <br> <br>2<br>450<br>5CLS-24R (2200)†<br>JCL-24R (1880)<br>5LCLS-24R (2200)<br>* Does not comply with ANSI C37.46 for "R" rating.<br>† UL Recognized.<br>|<br> <br>2<br>450<br>5BCLS-24R (2200)†<br>JCL-B-24R (1880)<br>600<br>5BCLS-32R (3000)<br>—<br>650<br>5BCLS-36R (3200)<br>—<br>800<br>5BCLS-44R (3600)<br>—|
|---|---|
|AMPGARD Hookeye (min. interruptingratingin amps)<br>No. of<br>barrels<br>Amps<br>Hookeye<br>Hookeye<br>Hermetic seal<br>30<br>5ACLS-30* (100)†<br>—<br>5HCLS-30* (100)<br>1<br>70<br>5ACLS-2R (180)†<br>JCL-A-2R (165)†<br>5HCLS-2R (180)<br>100<br>5ACLS-3R (270)†<br>JCL-A-3R (220)†<br>5HCLS-3R (270)<br>130<br>5ACLS-4R (360)†<br>JCL-A-4R (320)†<br>5HCLS-4R (360)<br>150<br>5ACLS-5R (450)†<br>JCL-A-5R (410)†<br>5HCLS-5R (450)<br>170<br>5ACLS-6R (540)†<br>JCL-A-6R (480)†<br>5HCLS-6R (540)<br>200<br>5ACLS-9R (740)†<br>JCL-A-9R (720)†<br>5HCLS-9R (740)<br>230<br>5ACLS-12R (1080)†<br>JCL-A-12R (970)†<br>5HCLS-12R (1080)<br>390<br>5ACLS-18R (1500)†<br>JCL-A-18R (1430)<br>5HCLS-18R (1500)<br>2<br>450<br>5ACLS-24R (2200)†<br>JCL-A-24R (1880)<br>5HCLS-24R (2200)<br>* Does not comply with ANSI C37.46 for "R" rating.<br>† UL Recognized.|* Does not comply with ANSI C37.46 for "R" rating.<br>† UL Recognized.|
||GE Limitamp(min. interruptingratingin amps)<br>No. of<br>barrels<br>Amps<br>Bolt-on<br>Bolt-on|
||30<br>—<br>—<br>1<br>70<br>5MCLS-2R-A (180)†<br>5MCLS-2R-B (180)†<br>100<br>5MCLS-3R-A (270)†<br>5MCLS-3R-B (270)†<br>130<br>5MCLS-4R-A (360)†<br>5MCLS-4R-B (360)†<br>150<br>5MCLS-5R-A (450)†<br>5MCLS-5R-B (450)†<br>170<br>5MCLS-6R-A (540)†<br>5MCLS-6R-B (540)†<br>200<br>5MCLS-9R-A (850)†<br>5MCLS-9R-B (850)†<br>230<br>5MCLS-12R-A (1150)†<br>5MCLS-12R-B (1150)†|
||390<br>5MCLS-18R-A (1725)†<br>5MCLS-18R-B (1725)†<br>2<br>450<br>5MCLS-24R-A (2350)†<br>5MCLS-24R-B (2350)†|
- Does not comply with ANSI C37.46 for "R" rating.
† UL Recognized.
## 5CLS, JCL, JCL-A, 5ACLS and 5HCLS Type mountings — in (mm)
**==> picture [537 x 234] intentionally omitted <==**
**----- Start of picture text -----**<br>
Hole centers BIL<br>Catalog no. A B Overall length C Hole inset D Hole ctr. E Contact hgt. F Overall hgt. G (kV)<br>Disconnect single barrel [†]<br>5CLE-GDM-D<br>15.24 (387.1) 25 (647.7)<br>5CLE-PDM-D<br>6 (152.4) 0.62 (15.7) 1.75 (44.4) 4.5 (114.3) 11.72 (297.7) 60<br>5HLE-PDM-D<br>16.25 (412.8) 23 (584.2)<br>5HLE-GDM-D<br>Disconnect double barrel [†]<br>5CLE-GDM-E<br>15.24 (387.1) 25 (647.7)<br>5CLE-PDM-E<br>6 (152.4) 0.62 (15.7) 1.75 (44.4) 4.5 (114.3) 15.28 (388.1) 60<br>5HLE-GDM-E<br>16.25 (412.8) 23 (584.2)<br>5HLE-PDM-E<br>Non-disconnect single barrel<br>5CLE-GNM-D<br>15.24 (387.1) 25 (635.0)<br>5CLE-PNM-D<br>6 (152.4) 0.62 (15.7) 1.75 (44.4) 4.5 (114.3) 8.79 (223.3) 60<br>5HLE-GNM-D<br>16.25 (412.7) 23 (584.2)<br>5HLE-PNM-D<br>Non-disconnect double barrel<br>5HLE-PNM-E<br>16.25 (412.7) 6 (152.4) 25 (635.0) 0.62 (15.7)\ 1.75 (44.4) 4.5 (114.3) 12.48 (317.0) 60<br>5HLE-GNM-E<br>**----- End of picture text -----**<br>
Data sheet no. 6001
Eaton.com/bussmannseries
7-24
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## 7.2 kV R-Rated fuses
## Catalog symbols/construction
- 8CLS-_R/Standard (2R - 6R)
- 8ACLS-_R/AMPGARD Hookeye* (2R - 6R)
- 7BCLS-_R/Bolt-on (2R - 6R)
## Dimensions — in (mm)
|Construction<br>Amps|Dimension|
|---|---|
||A<br>B<br>C|
|Standard<br>70-170<br>AMPGARD Hookeye<br>Bolt-on|15.8 (401)<br>3 (76)<br>3 (76)<br>19.2 (488)<br>17.9 (455)|
Standard and AMPGARD Hookeye
* For use in 400 amp AMPGARD motor starters.
Ratings
- Volts
- 7.2 kV (nominal)
- 8.3 kV (max design 70-170 A standard and AMPGARD Hookeye)
- 7.2 kV (max design 70-170 A bolt-on)
**==> picture [263 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
Gripping tab<br>for Hookeye<br>constructions Indicator<br>C<br>B<br>A<br>**----- End of picture text -----**<br>
- Amps 70-170 A
- Interrupting ratings
- 50 kA Sym.
- 80 kA Asym.
Recommended fuseclips and holders for standard constructions
|Amps<br>Description<br>BIL(kV)|Amps<br>Description<br>BIL(kV)|Cat. No.|
|---|---|---|
|Fuseclips|||
|70-170|3” Enclosed fuseclip*<br>—<br>3” Open fuseclip<br>3” Springloaded open fuseclip|A3354730|
|||1A0065|
|||9078A67G04|
|Fuse holders for 7CLS and 8CLS|||
|70-170|Non-disconnect holder, porcelain<br>75<br>Non-disconnect holder, glasspolyester<br>Disconnect holder, porcelain<br>Disconnect holder, glasspolyester|8HLE-PNM-D|
|||8HLE-GNM-D|
|||8HLE-PDM-D|
|||8HLE-GDM-D|
## Bolt-on
**==> picture [262 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
R 0.23 [5.81] Typ.<br>E F G H I<br>E = 3 [76.2]<br>F = 2.5 [63.5]<br>G = 2.04 [51.81<br>H = 0.96 [24.4]<br>I = 0.5 [12.7]<br>Indicator<br>C<br>2.12<br>[53.8]<br>B<br>3.0 A<br>[76.2]<br>**----- End of picture text -----**<br>
- Single barrel only, not sold in pairs.
## 7.2 kV R-Rated fuse catalog numbers
|Amps<br>“R” Designation|Mountingstyle (minimum interruptingratingin amps)<br>No. of barrels<br>Standard<br>AMPGARD Hookeye<br>Bolt-on|
|---|---|
|70<br>2R|8CLS-2R (160)<br>8ACLS-2R (160)<br>7BCLS-2R (160)<br>1<br>8CLS-3R (250)<br>8ACLS-3R (250)<br>7BCLS-3R (250)<br>8CLS-4R (325)<br>8ACLS-4R (325)<br>7BCLS-4R (325)<br>8CLS-5R (390)<br>8ACLS-5R (390)<br>7BCLS-5R (390)<br>8CLS-6R (500)<br>8ACLS-6R (500)<br>7BCLS-6R (500)|
|100<br>3R||
|130<br>4R||
|150<br>5R||
|170<br>6R||
Data sheet no. 6001
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-25
**7 — Medium voltage fuses** ~~TA~~
## E-Rated PT medium voltage fuses
Catalog symbols (by maximum voltage rating)
|•|2.475 kV|• 12 kV|
|---|---|---|
||• 2NCLPT-_|• 12ABCNA_|
|•|3.6 kV|• 12CAV_|
||• 3.6ABCNA_|• 15.5 kV|
||• 3.6ABWNA_|• 15CLPT-_E|
||• 3.6CAV_|• 15NCLPT-_E-A|
|•|5.5 kV|• 15NCLPT-_E-B|
||• JCW-_|• 15.5CAV_E|
||• 5CLPT-_E|• 15.5CAVH_E|
||• 5NCLPT-_E|• 17.5 kV|
||• 5NCLPT-_E-A|• 17.5ABGNA_|
||• 5.5ABWNA_E|• 17.5CAV_|
||• 5.5AMWNA_E|• 24 kV|
||• 5.5CAV_E|• 24ABGNA_|
||• 5.5CAVH_E|• 24CAV_|
|•|7.2 kV|• 25.5 kV|
||• 7.2ABWNA_|• 25CLPT-_E|
||• 7.2ABCNA_|• 36 kV|
||• 7.2AMWNA_E|• 36ABGNA_|
||• 7.2CAV_|• 36CAV_|
|•|8.3 kV|• 38 kV|
||• 8CLPT-_E-A|• 38CAV_E|
||• 8NCLPT-_E|• 38CAVH_E|
||• 8NCLPT-_E-A|• 38CLPT-_E|
||• 8NCLPT-_E-B||
Dimensions — in (mm) | -—_ C ~~—~~ B A Recommended fuseclip and block ~~kee~~ Description Catalog no. Open fuseclip for 0.8 (20 mm) dia. fuses 1A1837 Single-pole open fuse block with #10-32 phil-slot screw terminals rated 2500 V, 5 A maximum and PTFB-2500-JCD 63 kA withstand rating
## Ratings*
- Volts 2.4 kV to 38 kV
- Amps 0.25 to 15 A
- Interrupting ratings 25 to 80 kA RMS Sym.
- See catalog number tables for voltages, ampacities and interrupting ratings by catalog number.
## Agency information
- PT fuses conforming to the requirements for E-Rating meet the performance characteristics of IEEE/ANSI C37.46
Data sheet no. 6002
Eaton.com/bussmannseries
7-26
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## 2.475 to 38 kV PT E-Rated fuses
|Amps|Dimensions — in (mm)|Dimensions — in (mm)||Medium voltage<br>fuses<br>Catalog no. (IR - kA)<br>Recommended<br>fuseclip<br>Indicating<br>Non-indicating<br>—<br>2NCLPT-.25E (63)<br>1A1837<br>—<br>2NCLPT-.5E (63)<br>—<br>2NCLPT-1E (40)<br>—<br>2NCLPT-2E (40)<br>—<br>2NCLPT-5E (25)<br>—<br>3.6CAV2 (50)<br>1A1837<br>—<br>3.6ABWNA3.15 (50)<br>A3354705<br>—<br>3.6ABCNA3.15 (50)<br>—<br>3.6ABWNA6.3 (50)<br>—<br>3.6ABCNA6.3 (50)<br>—<br>3.6ABCNA10 (50)<br>—<br>5.5AMWNA0.5E (63)<br>1A1837<br>—<br>5.5ABWNA0.5E (50)<br>A3354705<br>5.5CAVH0.5E (50)<br>JCW-1/2E (40)<br>1A0835<br>5CLPT-.5 (80)†<br>5NCLPT-.5E-A (63)<br>1A0835<br>—<br>5.5ABWNA1E (50)<br>A3354705<br>—<br>5.5AMWNA1E (63)<br>1A1837<br>5.5CAVH1E (50)<br>JCW-1E (40)<br>1A0835<br>5CLPT-1 (80)†<br>5NCLPT-1E-A (63)<br>5CLPT-1.5 (80)†<br>—<br>—<br>5.5ABWNA2E (50)<br>A3354705<br>—<br>5.5AMWNA2E (63)<br>1A1837<br>5.5CAVH2E (50)<br>JCW-2E (40)<br>1A0835<br>—<br>5NCLPT-2E (63)<br>1A1837<br>—<br>5.5ABWNA3E (50)<br>A3354705<br>—<br>5.5AMWNA3E (63)<br>1A1837<br>5CLPT-3E (80)<br>5NCLPT-3E (63)<br>1A0835<br>—<br>JCW-3E (40)<br>—<br>5.5AMWNA4E (63)<br>1A1837<br>5CLPT-5E (80)<br>5NCLPT-5E-A (63)<br>1A0835<br>—<br>5.5ABWNA5E (50)<br>A3354705<br>—<br>5.5AMWNA5E (63)<br>1A1837|
|---|---|---|---|---|
||Length A|Diameter B|Clip centers C||
|2.475 kV maximum|system voltage||||
|0.25|4.5 (114)|0.8 (20)|3.9 (99)||
|0.5|||||
|1|||||
|2|||||
|5|||||
|3.6 kV maximum system voltage|||||
|2<br>8.7 (221)||1.6 (41)|7.6 (193)||
|3.15<br>5.6 (142)||1 (25)|4.4 (112)||
|3.15<br>7.7 (195)|||6.5 (165)||
|6.3<br>5.6 (142)|||4.4 (112)||
|6.3<br>7.7 (195)<br>10|||6.5 (165)||
|5.5 kV maximum system voltage|||||
|0.5<br>5.6 (142)<br>0.5||0.8 (20)|4.8 (122)||
|||1 (25)|4.4 (112)||
|0.5<br>7.4 (188)||1.6 (41)|6.2 (157)||
|0.5<br>9.5 (241)||1.6 (41)|8.1 (206)||
|1<br>5.6 (142)<br>1||1 (25)|4.4 (112)||
|||0.8 (20)|4.8 (122)||
|1<br>7.4 (188)||1.6 (41)|6.2 (157)||
|1<br>9.5 (241)<br>1.5|||8.1 (206)||
|2<br>5.6 (142)<br>2||1 (25)|4.4 (112)||
|||0.8 (20)|4.8 (122)||
|2<br>7.4 (188)||1.6 (41)|6.2 (157)||
|2<br>9.5 (241)|||8.1 (206)||
|3<br>5.6 (142)<br>3||1 (25)|4.4 (112)||
|||0.8 (20)|4.8 (122)||
|3<br>9.5 (241)||1.6 (41)|8.1 (206)||
|3<br>7.4 (188)|||6.2 (157)||
|4<br>5.6 (142)||0.8 (20)|4.8 (122)||
|5<br>9.5 (241)||1.6 (41)|8.1 (206)||
|5<br>5.6 (142)<br>5||1 (25)|4.4 (112)||
|||0.8 (20)|4.8 (122)||
|5<br>7.3 (185)||1.6 (41)|5.9 (150)|—<br>JCW-5E (40)<br>1A0835<br>5CLPT-10E (80)<br>5NCLPT-10E-A (63)<br>—<br>5.5CAV15E (50)|
|10<br>9.5 (241)|||8.1 (206)||
|15<br>7.4 (188)|||6.2 (157)||
† Due to manufacturing variations, this fuse does not comply with ANSI C37.46 for "E" rating.
Data sheet no. 6002
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-27
## **7 — Medium voltage fuses**
## 2.475 to 38 kV PT E-Rated fuses
**==> picture [536 x 655] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in (mm) Catalog no. (IR - kA)<br>Recommended<br>Amps Length A Diameter B Clip centers C Indicating Non-indicating fuseclip<br>7.2 kV maximum system voltage<br>0.5 7.2AMWNA0.5E (50)<br>1 5.6 (142) 0.8 (20) 4.8 (122) 7.2AMWNA1.0E (50) 1A1837<br>2 7.2AMWNA2.0E (50)<br>2 8.7 (221) 1.6 (41) 7.5 (190) 7.2CAV2 (40) 1A0835<br>3 5.6 (142) 0.8 (20) 4.8 (122) 7.2AMWNA3.0E (50) 1A1837<br>3.15 5.6 (142) 4.4 (112) 7.2ABWNA3.15 (45)<br>1 (25.4) A3354705<br>3.15 7.7 (195) 6.5 (165) 7.2ABCNA3.15 (45)<br>—<br>4 5.6 (142) 0.8 (20) 4.8 (122) 7.2AMWNA4.0E (50) 1A1837<br>4 8.7 (221) 1.6 (41) 7.5 (190) 7.2CAV4 (40) 1A0835<br>5 5.6 (142) 0.8 (20) 4.8 (122) 7.2AMWNA5E (50) 1A1837<br>6 8.7 (221) 1.6 (41) 7.5 (190) 7.2CAV6 (40) 1A0835<br>6.3 5.6 (142) 4.4 (112) 7.2ABWNA6.3 (45)<br>1 (25.4) A3354705<br>6.3 7.7 (195) 6.5 (165) 7.2ABCNA6.3 (45)<br>10 8.7 (221) 1.6 (41) 7.5 (190) 7.2CAV10 (40) 1A0835<br>8.3 kV maximum system voltage<br>0.5 9.5 (241) 1.6 (41) 8.1 (206) 8CLPT-.5 (80) [†] 8NCLPT-.5E-A (50) 1A0835<br>1 5 (127) 1.1 (28) 4 (102) 8NCLPT-1E (50) A3354705<br>1 9.5 (241) 1.6 (41) 8.1 (206) 8NCLPT-1E-A (50) 1A0835<br>—<br>2 8 (203) 0.8 (20) 7.2 (183) 8NCLPT-2E (25) 1A1837<br>2 9.5 (241) 8.1 (206) 8NCLPT-2E-A (50)<br>1.6 (41) 1A0835<br>3 12.9 (328) 11.5 (292) 8CLPT-3E (80) 8NCLPT-3E-B (50)<br>4 8 (203) 0.8 (20) 7.2 (183) 8NCLPT-4E (25) 1A1837<br>—<br>5 5 (127) 1.1 (28) 4 (102) 8NCLPT-5E (50) A3354705<br>5 12.9 (328) 1.6 (41) 11.5 (292) 8CLPT-5E (80) 8NCLPT-5E-B (50) 1A0835<br>8 5 (127) 1.1 (28) 4 (102) — 8NCLPT-8E (50) A3354705<br>10 12.9 (328) 1.6 (41) 11.5 (292) 8CLPT-10E (80) 8NCLPT-10E-B (50) 1A0835<br>12 kV maximum system voltage<br>2 8.7 (221) 1.6 (41) 7.5 (190) 12CAV2 (40) 1A0835<br>—<br>3.15 7.7 (195) 1 (25) 6.5 (165) 12ABCNA3.15 (45) A3354705<br>15.5 kV maximum system voltage<br>0.5 15.5CAVH0.5E (80) 15NCLPT-.5E-A (50)<br>0.5 15CLPT-.5 (80) —<br>1 15.5CAVH1E (80) 15NCLPT-1E-A (50)<br>1 12.9 (328) 11.5 (292) 15CLPT-1 (80) —<br>1.5 15CLPT-1.5 (80) —<br>2 15.5CAVH2E (80) 15NCLPT-2E (50)<br>3 1.6 (41) 15.5CAV3E (80) 1A0835<br>—<br>3 17.6 (447) 15NCLPT-3E (50)<br>16.1 (409)<br>3 17.6 (447) 15CLPT-3E (80) —<br>5 12.9 (328) 11.5 (292) — 15.5CAV5E (80)<br>5 17.6 (447) 16.1 (409) 15CLPT-5E (80) 15NCLPT-5E (50)<br>7 12.9 (328) 11.5 (292) — 15.5CAV7E (80)<br>10 17.6 (447) 16.1 (409) 15CLPT-10E (80) 15NCLPT-10E (50)<br>17.5 kV maximum system voltage<br>2 17.5CAV2 (40)<br>4 17.5CAV4 (40)<br>8.7 (221) 1.6 (41) 7.5 (190) — 1A0835<br>6 17.5CAV6 (40)<br>10 17.5CAV10 (40)<br>**----- End of picture text -----**<br>
† Does not comply with ANSI C37.46 for "E" rating.
Data sheet no. 6002
Eaton.com/bussmannseries
7-28
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## 2.475 to 38 kV PT E-Rated fuses
|Amps|Dimensions — in (mm)||Catalog no. (IR - kA)|Recommended<br>fuseclip<br>Non-indicating|
|---|---|---|---|---|
||Length A<br>Diameter B|Clip centers C|Indicating||
|24 kV maximum system voltage|||||
|2<br>13.49 (340)<br>1.6 (41)<br>3<br>4||12.2 (310)|—|24CAV2 (40)<br>1A0835<br>24CAV3 (40)<br>24CAV4 (40)|
|25.5 kV maximum system voltage|||||
|0.5<br>17.6 (447)<br>1.6 (41)<br>1||16.1 (410)|25CLPT-.5 (43.5)†|—<br>1A0835|
||||25CLPT-1 (43.5)†||
|36 kV maximum system voltage|||||
|2<br>17.3 (439)<br>1.6 (41)<br>4||16.1 (410)|—|36CAV2 (40)<br>1A0835<br>36CAV4 (40)|
|38 kV maximum system voltage|||||
|0.5<br>17.3 (439)<br>1.6 (41)<br>0.5<br>18.6 (472)<br>1<br>17.3 (439)<br>2<br>4||16.1 (409)|38CAVH0.5E (40)|—<br>1A0835<br>—<br>—<br>—<br>38CAV4E (40)|
|||17.1 (434)|38CLPT-.5 (43.5)†||
|||16.1 (409)|38CAVH1E (40)||
||||38CAVH2E (40)||
||||—||
† Does not comply with ANSI C37.46 for “E” rating.
CLPT Type mountings and hardware
**==> picture [562 x 301] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog no.<br>Mounting (including live parts, end fittings)**<br>Fuse mounting BIL Live parts End fittings<br>Amps type* (kV) Porcelain insulator Glass-polyester insulator (including end fittings)*** (disconnect only)<br>5.5 kV maximum (4.8 kV nominal) [†]<br>Non-disconnect 5CLPT-PNM-A 5CLPT-GNM-A CLPT-NL —<br>0.5–10 60<br>Disconnect [††] 5CLPT-PDM-A 5CLPT-GDM-A CLPT-DL CLPT-DF<br>8.3 kV maximum (7.2 kV nominal) [†]<br>Non-disconnect 8CLPT-PNM-A 8CLPT-GNM-A CLPT-NL —<br>0.5–2<br>Disconnect [††] 8CLPT-PDM-A 8CLPT-GDM-A CLPT-DL CLPT-DF<br>75<br>Non-disconnect 8CLPT-PNM-B 8CLPT-GNM-B CLPT-NL —<br>3–10<br>Disconnect [††] 8CLPT-PDM-B 8CLPT-GDM-B CLPT-DL CLPT-DF<br>15.5 kV maximum (14.4 kV nominal)<br>Non-disconnect 15CLPT-PNM-A 15CLPT-GNM-A CLPT-NL —<br>0.5–2<br>Disconnect [††] 15CLPT-PDM-A 15CLPT-GDM-A CLPT-DL CLPT-DF<br>95<br>Non-disconnect 15CLPT-PNM-B 15CLPT-GNM-B CLPT-NL CLPT-DF<br>3–10<br>Disconnect [††] 15CLPT-PDM-B 15CLPT-GDM-B CLPT-DL —<br>25.5 kV Maximum (23 kV Nominal)<br>Non-disconnect 25CLPT-PNM-A 25CLPT-NL —<br>0.5–1 150 —<br>Disconnect [††] 25CLPT-PDM-A 25CLPT-DL CLPT-DF<br>38 kV Maximum (34.5 kV Nominal)<br>Disconnect [††] Not applicable CLPT-NL CLPT-DF<br>0.5 N/A Not applicable<br>Non-disconnect 38CLPT-PNM-A CLPT-DL —<br>fuses<br>Medium voltage<br>**----- End of picture text -----**<br>
* See page 7-35 for dimensions and diagrams of typical mountings.
** End fittings supplied only when required.
† Refers to 5CLPT, 5NCLPT, 8CLPT and 8NCLPT-A or -B fuses only.
†† Disconnect mountings provide a means for fuse extraction only. Do not use a disconnect mounting for load switching or fuse removal while energized.
Data sheet no. 6002
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-29
**7 — Medium voltage fuses**
## HVA, HVB, HVJ, HVL, HVR, HVT, HVU, HVW and HVX fast-acting PT fuses
Medium voltage, non-time delay, fast-acting fuses.
## Ratings*
- Volts 1-10 kV
- Amps 1/16-10 A
- See catalog number table for possible volt/amp combinations.
## Features
- Physical size varies with electrical rating of fuse to prevent overfusing
- Space-saving size
## Typical applications
- Medium voltage instrument and circuit protection
## Test specifications
|Catalog symbol<br>Percent load|Opening time|
|---|---|
|110|4 hours (min)|
|HVA, HVB, HVJ, HVL||
|135|1 hour (max)|
|100|4 hours (min)|
|HVR, HVT, HVU, HVW, HVX||
|150|1 hour (max)|
## Recommended fuseclips and blocks
|Fuse catalog symbol|Fuse catalog symbol|Fuse catalog symbol<br>Block catalog no.|Block catalog no.<br>Fuseclip catalog no.|
|---|---|---|---|
|HVA, HVR|HVA, HVR|4528*||
||||5960|
|HVB, HVT|HVB, HVT|4529*||
|HVJ, HVU|HVJ, HVU|||
|||—|4180|
|HVL, HVX|HVL, HVX|||
* Use #8 screws.
|||||Dimensions — in (mm)|Dimensions — in (mm)|
|---|---|---|---|---|---|
|Catalog symbol|Catalog symbol<br>kV|Amps|Max. IR (amps)|Diameter|Length|
|HVA|1|1/16, 1/10, 1/8, 2/10, 1/4, 3/8, 1/2, 3/4, 1, 1-1/2, 2, 3, 4, 6, 10|20 DC / 30 AC||3 (76)|
|||||0.4 (10)||
|HVB|2.5|1/2, 3/4, 1, 1-1/2, 2, 3|8 DC / 12 AC||4.5 (114)|
|HVJ|5|1/16, 1/8, 1/4, 1/2, 3/4, 1, 1-1/2, 2, 4, 6*|4 DC / 6 AC||5 (126.9)|
|||||0.8 (21)||
|HVL|10|1/16, 1/8, 1/4, 1/2, 1, 1-1/2, 2, 3*|2 DC / 3 AC||10 (254)|
|HVR|1|1/2, 1, 2, 3, 4, 5|500 AC||3 (76)|
|HVW|1.2|1, 2, 3, 4, 5, 8|4 DC / 167 AC|0.4 (10)|2.3 (57)|
|HVT|2.5|1/2, 1, 2, 3, 5|500 AC||4.5 (114)|
|HVU|5|1/2, 1, 2, 3, 4, 5|500 AC||5 (127)|
|||||0.8 (20)||
|HVX|10|1/2, 1, 3, 5|1200 AC||10 (254)|
* AC only.
## Catalog number build-a-code
Fuse catalog symbol Amps
_ _ _ _ _ - _ _ _
E.g., HVB-3/4 (2.5 kV 3/4 amp fuse)
Data sheet no. 6003
Eaton.com/bussmannseries
7-30
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## British standard dimensioned IEC fuses for motor circuit protection
The Bussmann series IEC motor fuses are designed to meet the specific requirements necessary for motor protection. During the starting cycle of direct on-line motors, the fuse elements will reach a considerably higher temperature than during normal operation; (this is due to the high amount of current the motor will draw as it starts, typically, six times its normal load current value). This results in expansion and contraction of the fuse elements and could cause premature operation of the fuse.
Bussmann series motor fuses encompass an advanced design to minimize this effect. This, therefore, negates the need to over specify the fuse rating due to high values of motor starting current.
These motor fuses operate extremely quickly under heavy fault currents, resulting from the time / current characteristic. Low power dissipation ensures low temperature rise, important in multitier starters for example. Switching (arc), voltages are lower than permitted values, therefore, 5.5 kV fuses are also suitable for 4.8 kV and 2.4 kV circuits.
|Catalog<br>symbol<br>kV|IR<br>(kA)|Amps/rating|Dimensions — in(mm)<br>Length<br>Diameter|Dimensions — in(mm)<br>Length<br>Diameter|Dimension standard|
|---|---|---|---|---|---|
|3.6WJON6||5,6.3,10,16,20,25,31.5,40,50||1.4(36)|BS 2692(TA1)Interchangeable with GEC Type K2 PA|
|3.6WDOH6<br>3.6WFOH6||50,63,80,100,125<br>160,200|7.6 (192)|2(51)<br>3(76)|BS 2692 (TA1) or DIN 43625|
|3.6<br>3.6WDLSJ<br>3.6WFLSJ|50|50,63,80,100,125<br>160,200|11.5 (292)|2(51)<br>3(76)|DIN 43625|
|3.6WDFHO||50,63,80,100,125||2(51)||
|3.6WFFHO||160,200|10 (254)||BS 2692 (TA2)|
|3.6WKFHO||250,315,355,400||||
|5.5VFNHA<br>5.5|60|2R,3R,4R,6R|||ANSI R-Rated|
|5.5VKNHA<br>7.2WFNHO<br>7.2<br>7.2WKNHO|40|9R,12R,18R,24R<br>25,31.5,40,50,63,80,100,125,160<br>200,224,250,315|15.9 (403)|3 (76)|BS 2692 (TA4)|
|7.2WFMSJ<br>7.2WKMSJ|63|25,31.5,40,50,63,80,125,160<br>200,224,250,315,355|17.4 (442)||DIN 43625|
Catalog number build-a-code
Fuse catalog symbol Amps _ _ _ _ _ - _ _ _
E.g., 3.6WKFHO-315 (315 amp 3.6 kV fuse)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-31
**7 — Medium voltage fuses**
## DIN dimensioned IEC fuses for transformer protection
DIN dimension fuses to Specification DIN 43625 covering currentlimiting fuses with performance in compliance with IEC 60282-1. These are in accordance with the R10 and, in some cases, the R20 series of preferred numbers.
## Ratings*
- Volts 3.6-36 kV
- Amps 6.3-100 A
## Typical applications
- Medium voltage IEC designed equipment
Recommended fuseclips
- Catalog numbers 270303, A3354745, see page 7-36.
- Interrupting ratings 20-50 kA
- See catalog number table for possible volt/amp combinations.
## Agency information
- Compliant with DIN dimensional standard DIN 43625, VDE 0670 part 4, VDE 0670 part 40Z and with IEC 60282-1 (2005)
## Features
- DIN dimensioned for retrofitting in existing hardware
## Dimensions — in (mm)
**==> picture [262 x 69] intentionally omitted <==**
**----- Start of picture text -----**<br>
Striker -in<br>operated position<br>0.59<br>(15)<br>1.77<br>ao (45) : 1<br>=<br>KI Length ———— 1.34 | 1.02 |]<br>(34) (26)<br>Diameter<br>**----- End of picture text -----**<br>
For diameter and length values, see catalog number table.
- Open fuse indicator for ease in troubleshooting
> • Designed for use in IEC equipment
|kV<br>Catalog<br>symbol<br>Amps<br>Dimensions — in(mm)<br>IR RMS Sym.(kA)<br>Diameter<br>Length<br>3.6ADOSJ<br>6.3,10,16,20,25,31.5,40<br>2.0 (51)<br>7.6 (192)<br>40<br>3.6WDOSJ<br>50,63,80,100,125<br>~~eS~~<br>~~OO~~|kV<br>Catalog<br>symbol<br>Amps<br>Dimensions — in(mm)<br>IR RMS Sym.(kA)<br>Diameter<br>Length<br>3.6ADOSJ<br>6.3,10,16,20,25,31.5,40<br>2.0 (51)<br>7.6 (192)<br>40<br>3.6WDOSJ<br>50,63,80,100,125<br>~~eS~~<br>~~OO~~|kV<br>Catalog<br>symbol<br>Amps<br>Dimensions — in(mm)<br>IR RMS Sym.(kA)<br>Diameter<br>Length<br>3.6ADOSJ<br>6.3,10,16,20,25,31.5,40<br>2.0 (51)<br>7.6 (192)<br>40<br>3.6WDOSJ<br>50,63,80,100,125<br>~~eS~~<br>~~OO~~|kV<br>Catalog<br>symbol<br>Amps<br>Dimensions — in(mm)<br>IR RMS Sym.(kA)<br>Diameter<br>Length<br>3.6ADOSJ<br>6.3,10,16,20,25,31.5,40<br>2.0 (51)<br>7.6 (192)<br>40<br>3.6WDOSJ<br>50,63,80,100,125<br>~~eS~~<br>~~OO~~|kV<br>Catalog<br>symbol<br>Amps<br>Dimensions — in(mm)<br>IR RMS Sym.(kA)<br>Diameter<br>Length<br>3.6ADOSJ<br>6.3,10,16,20,25,31.5,40<br>2.0 (51)<br>7.6 (192)<br>40<br>3.6WDOSJ<br>50,63,80,100,125<br>~~eS~~<br>~~OO~~|kV<br>Catalog<br>symbol<br>Amps<br>Dimensions — in(mm)<br>IR RMS Sym.(kA)<br>Diameter<br>Length<br>3.6ADOSJ<br>6.3,10,16,20,25,31.5,40<br>2.0 (51)<br>7.6 (192)<br>40<br>3.6WDOSJ<br>50,63,80,100,125<br>~~eS~~<br>~~OO~~|kV<br>Catalog<br>symbol<br>Amps<br>Dimensions — in(mm)<br>IR RMS Sym.(kA)<br>Diameter<br>Length<br>3.6ADOSJ<br>6.3,10,16,20,25,31.5,40<br>2.0 (51)<br>7.6 (192)<br>40<br>3.6WDOSJ<br>50,63,80,100,125<br>~~eS~~<br>~~OO~~|
|---|---|---|---|---|---|---|
|3.6|3.6WFOSJ<br>3.6ADLSJ|160,200<br>25,40|3.0(76)<br>2.0(51)|||50|
|7.2|3.6WKLSJ<br>7.2TDLSJ<br>7.2TFLSJ|250,315,400<br>6.3,10,16,20,25,31.5,40,50,63<br>80,100,125,160|3.0(76)<br>2.0(51)<br>3.0(76)||11.5 (292)|40|
||12TDLEJ|6.3,10,16,20,25,31.5,40,50,63|2.0(51)||||
|12|12THLEJ<br>12TKLEJ<br>12TXLEJ*|80,100<br>125<br>160,200|2.5(64)<br>3.0(76)<br>3.5(88)||11.5 (292)|63|
||17.5TDLSJ*<br>17.5TFLSJ*|6.3,10,16,20,25,31.5,40<br>50|2.0(51)<br>3.0(76)|||35.5|
|17.5|17.5TDMEJ|6.3,10,16,20,25,31.5,40,50,63|2.0(51)||||
||17.5THMEJ|80,100|2.5(64)|||50|
||17.5TKMEJ|125|3.0(76)||||
||24TDMEJ|6.3,10,16,20,25,31.5,40,50|2.0(51)||17.4 (442)||
|24|24THMEJ<br>24TFMEJ|63<br>80,100*1|2.5(64)<br>3.0(76)|||50|
||24TXMEJ*|1252,160|3.5(88)|||31.5|
|36|36TDQSJ<br>36TFQSJ|3.153,6.3,10,16,20,25<br>31.5,40,50|2.0(51)<br>3.0(76)||21.2 (537)|35.5|
||36TXQEJ*|63|3.5(88)|||20|
- Not compliant with VDE 0670, part 402.
- 1 IR RMS Sym. is 63 kA
- 2 IR RMS Sym. is 40 kA
- 3 IR RMS Sym. is 20 kA
## Catalog number build-a-code
Fuse catalog symbol Amps
_ _ _ _ _ - _ _ _
E.g., 17.5THMEJ-80 (17.5 kV 80 amp fuse)
Eaton.com/bussmannseries
7-32
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
## Expulsion fuse links for use in high voltage distribution cut-outs
Expulsion fuse links available in a wide range of options from 15 to 72 kV in ANSI Type T and K characteristics. Expulsion fuse link current ratings should be selected on the basis of maximum expected transient no-damage currents rather than on full load current. In addition, the selection of higher current ratings will reduce the possibility of supply interruption due to transient surges such as those due to lightning strikes.
Links should be handled with a reasonable degree of care when installing. Excessively rough handling may damage the element.
It is normal, under certain fault conditions, for arc extinguishing material and/or metal particles to be expelled from the fuse assembly. It is therefore recommended that reasonable precautions be taken to prevent the installation being approached by unauthorized persons.
When ordering, select from the table below the characteristics in each column you need your fuse link to have.
Example: 15TB30 is a 15 kV, ANSI C 37-42 compliant fuse with a fixed button head terminal that is rated for 30 amps.
The fuse link assembly for a given range is standard to all rated voltages. The exception is the tail length that’s varied to suit the expulsion carrier dimensions of different ratings.
## Ratings*
- Volts 15-72 kV
- Amps 1-100 A
- Interrupting rating 8 kA approximate
- See catalog number configuring table for possible volt/amp combinations.
## Agency information
- Type T, complies with ANSI C37-42
- Type K, complies with ANSI C37-42
## Typical applications
- Primary side transformer protection
- Feeder protection
- Capacitor bank protection
Fuse label color coding
|Type|Color|Type|Color|
|---|---|---|---|
|||||
|XA|Pink|T|Green|
|K|Yellow|S|—|
Dimensions — mm (in)
~~A 125 (4.92)~~
~~125 (4.92)~~ Double tail ~~SS~~ Ø10 (0.39) Universal ~~—_~~ ——_ Button head —— Ø7.5 (0.29) Ø19 (0.75) Removeable button head Up to 50 A ~~rs A A ee 125 (4.92) ee~~ Double tail 11 (0.43) Universal S Ø19 (0.75) ~~S~~ Adjustable button for 65 to 100 a assembly only Button head ~~—~~ — 10.5 (0.41) Ø19 (0.75) Removeable button head 60-100 A ~~a A~~
Link kV A Link kV A ~~ee~~ 15 533 (21) 46 787 (31) 25 660 (26) 72 1016 (40
Notes: Type BR is similar to button head shown, except that the button head is attached via a 1/4" UNF thread. Tails can be cut to desired length.
## Features
- Wide range of options available from 15 kV to 72 kV in ANSI T and K characteristics.
- Extra rapid option also available.
|Catalog number configuration table|Catalog number configuration table|||
|---|---|---|---|
|Available voltage<br>ratings (kV)|1st letter = current characteristics type|2nd letter = termination type|Available amps<br>ratings|
||T = complies with ANSI C 37-42 requirements for<br>slow acting T characteristics|B = a fixed NEMA button head link||
||K = complies with ANSI C 37-42 requirements for|U = a universal link, with double tail and slip off||
||fast acting K characteristics|NEMA button head||
|15, 25, 46, 72|XA = this type of expulsion fuse link has an extra<br>rapid characteristic. It is suitable for applications<br>where a high degree of system protection is<br>required at the expense of discrimination.|D = double tailed link without NEMA button head|1, 2, 3, 4, 5, 6,<br>7.5, 8, 10, 12, 15,<br>20, 25, 30, 40,<br>50, 60, 65, 75,<br>80, 100|
||S = Solid links rated at 100 amps are also available|||
||in both button head and universal versions for<br>fitting into expulsion fuse carriers where required.<br>These can be ordered in a similar way using the|BR = as pattern B but the button head is attached via<br>a 1/4" UNF thread to allow use of an extension rod||
||abbreviation S, e.g. 15SB, etc.|||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-33
**7 — Medium voltage fuses**
## FL — Type H, and EEI-NEMA Type K and T fuses
Type H (high-surge), K and T universal tin element cutout fuses rated to 27 kV
Medium voltage fuses: Type H (high surge), EEI-NEMA Type K
|Medium voltage fuses: Type H (high surge), EEI-NEMA Type K<br>(fast-acting), EEI-NEMA Type T (time-delay).<br>High-surge, Type H fuses are<br>manufactured in ratings of 1,<br>2, 3, 5, and 8 amps and were<br>developed for primary fusing of<br>small-sized transformers. Type<br>H links are manufactured in the<br>universal button head design.<br>Type N fuses conform to previous<br>NEMA standards and are<br>superseded by Type K and T links.<br>Type N fuses are manufactured<br>g<br>\ [<br>Ve<br>ih<br>\\<br>A\\<br>\|Medium voltage fuses: Type H (high surge), EEI-NEMA Type K<br>(fast-acting), EEI-NEMA Type T (time-delay).<br>High-surge, Type H fuses are<br>manufactured in ratings of 1,<br>2, 3, 5, and 8 amps and were<br>developed for primary fusing of<br>small-sized transformers. Type<br>H links are manufactured in the<br>universal button head design.<br>Type N fuses conform to previous<br>NEMA standards and are<br>superseded by Type K and T links.<br>Type N fuses are manufactured<br>g<br>\ [<br>Ve<br>ih<br>\\<br>A\\<br>\|Medium voltage fuses: Type H (high surge), EEI-NEMA Type K|Medium voltage fuses: Type H (high surge), EEI-NEMA Type K|Medium voltage fuses: Type H (high surge), EEI-NEMA Type K<br>T <br>‘ie<br>\<br>\<br>y<br>\\<br>\|Medium voltage fuses: Type H (high surge), EEI-NEMA Type K<br>T <br>‘ie<br>\<br>\<br>y<br>\\<br>\|<br>\|Catalog no.<br>Amps<br>Type H high surge<br>EEI-NEMA<br>Type K fast-acting<br>Type T time-delay<br>Non-removable button-head for standard open or enclosed cutouts<br>FL11H1<br>FL11K1<br>FL11T1<br>1<br>FL11H2<br>FL11K2<br>FL11T2<br>2<br>FL11H3<br>FL11K3<br>FL11T3<br>3<br>FL11H5<br>FL11K5<br>FL11T5<br>5<br>—<br>FL11K6<br>FL11T6<br>6<br> ~~pe~~<br>~~———__—__->NY~~<br>~~ee~~<br>~~oo~~|Catalog no.<br>Amps<br>Type H high surge<br>EEI-NEMA<br>Type K fast-acting<br>Type T time-delay<br>Non-removable button-head for standard open or enclosed cutouts<br>FL11H1<br>FL11K1<br>FL11T1<br>1<br>FL11H2<br>FL11K2<br>FL11T2<br>2<br>FL11H3<br>FL11K3<br>FL11T3<br>3<br>FL11H5<br>FL11K5<br>FL11T5<br>5<br>—<br>FL11K6<br>FL11T6<br>6<br> ~~pe~~<br>~~———__—__->NY~~<br>~~ee~~<br>~~oo~~|Catalog no.<br>Amps<br>Type H high surge<br>EEI-NEMA<br>Type K fast-acting<br>Type T time-delay<br>Non-removable button-head for standard open or enclosed cutouts<br>FL11H1<br>FL11K1<br>FL11T1<br>1<br>FL11H2<br>FL11K2<br>FL11T2<br>2<br>FL11H3<br>FL11K3<br>FL11T3<br>3<br>FL11H5<br>FL11K5<br>FL11T5<br>5<br>—<br>FL11K6<br>FL11T6<br>6<br> ~~pe~~<br>~~———__—__->NY~~<br>~~ee~~<br>~~oo~~|Catalog no.<br>Amps<br>Type H high surge<br>EEI-NEMA<br>Type K fast-acting<br>Type T time-delay<br>Non-removable button-head for standard open or enclosed cutouts<br>FL11H1<br>FL11K1<br>FL11T1<br>1<br>FL11H2<br>FL11K2<br>FL11T2<br>2<br>FL11H3<br>FL11K3<br>FL11T3<br>3<br>FL11H5<br>FL11K5<br>FL11T5<br>5<br>—<br>FL11K6<br>FL11T6<br>6<br> ~~pe~~<br>~~———__—__->NY~~<br>~~ee~~<br>~~oo~~|
|---|---|---|---|---|---|---|---|---|---|---|
|in the universal button design<br>in ratings of 5 through 200<br>amps for use in standard NEMA<br>dimensioned cutouts rated|I<br>MN<br>_<br>\<br>\||\\<br>vai<br>\<br>J<br>4<br>f<br>\||||FL11H8<br>FL11K8<br>FL11T8<br>8<br>—<br>FL11K10<br>FL11T10<br>10<br>—<br>FL11K12<br>FL11T12<br>12<br>~~es~~||||
|through 27 kV.<br>Ratings*<br>• Volts rated to 27 kV|N\\,<br>AR|\|S\|;<br>eo|}||—<br>FL11K15<br>FL11T15<br>15<br>—<br>FL11K20<br>FL11T20<br>20<br>—<br>FL11K25<br>FL11T25<br>25<br>—<br>FL11K30<br>FL11T30<br>30<br>~~ooooaaDDDWDWDD$4IDDG~~~~**I**I~~<br>~~I~~||||
|• Amps 1-200 A|||||||—|FL11K40|FL11T40|40|
|* See catalog number table for type and amp combinations.|||||||—|FL11K50|FL11T50|50|
|Features<br>• Wide range of EEI-NEMA type fuse links for use in open fuse<br>cutouts|Wide range of EEI-NEMA type fuse links for use in open fuse|Wide range of EEI-NEMA type fuse links for use in open fuse|||Wide range of EEI-NEMA type fuse links for use in open fuse||—<br>—<br>—|FL11K65<br>FL11K80<br>FL11K100|FL11T65<br>FL11T80<br>FL11T100|65<br>80<br>100|
|• Voltage rating up to 27 kV for flexible application|||||||—|FL11K140|FL11T140|140|
|• Can be coordinated with other overcurrent protective devices for||||||Can be coordinated with other overcurrent protective devices for|—|FL11K200|FL11T200|200|
|sectionalizing to isolate feeder branches|||||||Removable button-head for cutouts requiring removable-button links*||||
|Typical applications|||||||—|FL3K1|FL3T1|1|
||||||||—|FL3K2|FL3T2|2|
|• Medium voltage fused cutouts|||||||—|FL3K3|FL3T3|3|
||||||||—|FL3K5|FL3T5|5|
||||||||—|FL3K6|FL3T6|6|
||||||||—|FL3K8|FL3T8|8|
||||||||—|FL3K10|FL3T10|10|
||||||||—|FL3K12|FL3T12|12|
||||||||—|FL3K15|FL3T15|15|
|Type K universal silver-element cutout fuses rated to 27 kV||||Type K universal silver-element cutout fuses rated to 27 kV|||—|FL3K20|FL3T20|20|
|Catalog no.<br>Fast-acting EEI-NEMA Type K|||Amps||||—<br>—<br>—|FL3K25<br>FL3K30<br>FL3K40|FL3T25<br>FL3T30<br>FL3T40|25<br>30<br>40|
|Non-removable button-head for standard open or enclosed cutouts|||||||—|FL3K50|FL3T50|50|
|FL12K8|||8||||—|FL3K65|FL3T65|65|
|FL12K10|||10||||—|FL3K80|FL3T80|80|
|FL12K12|||12||||—|FL3K100|FL3T100|100|
|FL12K15|||15||||—|FL3K140|FL3T140|140|
|FL12K25|||25||||—|FL3K200|FL3T200|200|
|FL12K50|||50||||* Adapter-type removable-button links with ferrule adapter to convert to dou-|* Adapter-type removable-button links with ferrule adapter to convert to dou-|* Adapter-type removable-button links with ferrule adapter to convert to dou-|* Adapter-type removable-button links with ferrule adapter to convert to dou-|
- Adapter-type removable-button links with ferrule adapter to convert to double-leader links are available in K and T types. Order by description.
Eaton.com/bussmannseries
7-34
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Medium voltage fuses — 7**
PT fuse mountings — in (mm)
**==> picture [537 x 365] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog no. Hole ctrs. A Hole ctrs. B Overall length C Hole Inset D Hole ctrs. E Contact hgt. F Overall hgt. G BIL (kV)<br>5.5 kV Disconnect [†]<br>5CLPT-GDM-A<br>9.37 (238) 6 (152.4) 18.63 (473.2) 0.75 (19) 1.75 (44.4) 4.5 (114.3) 9.56 (242.8) 60<br>5CLPT-PDM-A<br>5.5 kV Non-disconnect<br>5CLPT-GNM-A<br>9.37 (238) 6 (152.4) 18.63 (473.2) 0.75 (19) 1.75 (44.4) 4.5 (114.3) 6.94 (176.2) 60<br>5CLPT-PNM-A<br>8.3 kV Disconnect [†]<br>8CLPT-GDM-A<br>8CLPT-GDM-B 9.37 (238) 18.63 (473.2)<br>6 (152.4) 0.75 (19) 1.75 (44.4) 7 (177.8) 12.06 (306.3) 75<br>8CLPT-PDM-A<br>8CLPT-PDM-B 12.74 (323.6) 22 (558.8)<br>8.3 kV Non-disconnect<br>8CLPT-GNM-A<br>9.37 (238) 18.63 (473.2)<br>8CLPT-PNM-A<br>6 (152.4) 0.75 (19) 1.75 (44.4) 7 (177.8) 9.44 (239.8) 75<br>8CLPT-GNM-B<br>12.75 (323.8) 22 (558.8)<br>8CLPT-PNM-B<br>15.5 kV Disconnect [†]<br>15CLPT-GDM-A<br>12.74 (323.6) 22 (558.8)<br>15CLPT-PDM-A<br>6 (152.4) 0.75 (19) 1.75 (44.4) 7 (177.8) 12.06 (306.3) 95<br>15CLPT-GDM-B<br>17.46 (443.5) 26.63 (676.4)<br>15CLPT-PDM-B<br>15.5 kV Non-disconnect<br>15CLPT-GNM-A<br>12.74 (323.6) 22 (558.8)<br>15CLPT-PNM-A<br>6 (152.4) 0.75 (19) 1.75 (44.4) 7 (177.8) 9.44 (239.8) 95<br>15CLPT-GNM-B<br>17.46 (443.5) 26.63 (676.4)<br>15CLPT-PNM-B<br>25.5 kV Disconnect [†]<br>25CLPT-PDM-A 19.12 (485.6) 7 (177.8) 26.63 (676.4) 0.75 (19) 1.75 (44.4) 12 (304.8) 17.06 (433.3) 150<br>25.5 kV Non-disconnect<br>25CLPT-PNM-A 26.63 (676.4) 7 (177.8) 26.63 (676.4) 0.75 (19) 1.75 (44.4) 12 (304.8) 14.75 (374.6) 150<br>**----- End of picture text -----**<br>
† Disconnect mountings provide a means for fuse extraction only. Do not use a disconnect mounting for load switching or fuse removal while energized.
Disconnect mountings[††]
Non-disconnect mountings
**==> picture [519 x 272] intentionally omitted <==**
**----- Start of picture text -----**<br>
G G<br>D F D F<br>E E<br>A C A C<br>E E<br>D B D B<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
7-35
**7 — Medium voltage fuses**
Recommended fuseclips
||||ClipDimensions — in (mm)|ClipDimensions — in (mm)|Dimensions — in (mm)||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Description|Fuse dia. — in (mm)|Fig.|A|B|Ø C|D|E|F|G|Catalogno.|
|DIN clipand stirrup<br>Enclosed fuseclip|1.8 (45)|1<br>2|—<br>3.5 (89)|—<br>2.5 (63)|—<br>1.8 (45)|—|—<br>4.4 (112)|—|—|270303<br>A3354745*|
|Enclosed fuseclip|2 (51)|2|3.75 (95)|1.98 (50)|2.01 (51)|1.19 (30)|4.54 (115)|1.5 (38)|0.4 (10)|A3354710*|
|Enclosed fuseclip||2|4.14 (105)|2.45 (62)|3.01 (76)||5.64 (143)|||A3354730*|
|Open fuseclip<br>Spring loaded open fuseclip|3 (76)|3<br>4|||See dimensions drawing|||||1A0065<br>9078A67G04|
* For single barrel applications only. Not sold in pairs.
**==> picture [32 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Figure 1<br>**----- End of picture text -----**<br>
**==> picture [105 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
|<br>26.5 6.5<br>Cof-——-ab——,CCD<br>**----- End of picture text -----**<br>
**==> picture [203 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
Figure 2 t<br>ØC<br>yj} [-) A<br>» 4 ; D<br>B<br>—<br>G te I<br>aic F = ||===<br>E<br>**----- End of picture text -----**<br>
**==> picture [31 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Figure 3<br>**----- End of picture text -----**<br>
**==> picture [32 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Figure 4<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
7-36
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## Contents
||||||Fuse size/<br>class|Description|Section<br>page|
|---|---|---|---|---|---|---|---|
||||||Quickguide||2-3|
|Save up to 65% panel space<br>with Bussmann series power<br>distribution fuse blocks|||||Controlpanel applications<br>1/4" dia.<br>Panel mount blocks 8000,3828,4520,4393<br>Class CC and midget<br>Modular blocks BCM,BMM<br>DIN-Rail holders CHCC,CHM,NDNF1,OPM<br>Panel mount blocks 3743,4421,4515||4-5<br>6-7<br>8-13<br>14|
||||||Class G|||
|||||||Panel mount blocks BG,G|15|
||||||14mm dia.|||
|||||||DIN-Rail holder CH14|16|
|see||||22mm dia.<br>DIN-Rail holder CH22<br>Modular block JM70100<br>Modular power distribution blocks JM70100_<br>MW_<br> ~~a~~|||17<br>18|
||||||Class H(K)/R|||
|a<br>i ‘<br>| ifIP. ”||||Modular blocks HM,RM<br>19-23<br>Modular power distribution blocks HM___MW_,<br>RM___MW_<br>24-27<br>Class J<br>DIN-Rail holders CH30J,CH60J<br>28<br>SafetyJ™ JT(N)600<br>29<br>~~CC~~<br> ~~d,s~~||||
|||||||Panel mountpyramid block JP|30|
|||||||Modular blocks JM60_|31-32|
|||||||Modularpower distribution blocks JM60___MW_|33-34|
||||||Class T|||
|||||||300 Vpanel mount blocks T300|35-36|
|||||||600 Vpanel mount blocks T600|37-38|
||||||High speed fuses|||
|||||||Open center panel mount blocks BH, C5268,<br>1BS|39|
|Sr||te||||NH fuses<br>DIN-Rail/panel mount blocks SD00, SD1, SD2,<br>SD3,SD4,TD00,TD1,TD2,TD3<br>40<br>Through-panel applications<br> ~~OO~~|||
||||||5mm dia.|HTB|41|
||||||1/4" dia.|HJL,HK,HKP,HLD|42-43|
||||||13/32" dia.|HPC,HPC-D,HPD,HPF,HPG,HPM,HPS,HPS2|43-45|
||||||In-line applications|||
||||||5mm dia.|HHT|46|
||||||1/4" dia.|HFA,HFB,HEB-10,HHB,HR/HM,HRK|46-48|
||||||Class G|Single-pole HEC,HEG,HEH,HEJ non-breakaway|49|
||||||13/32" dia.|HEB single-pole breakawayand non-breakaway|51-52|
||||||Class CC|HEZ waterproof single-pole breakaway and<br>non-breakaway|52|
||||||13/32" dia.|HEX, Class CC HEY dual-pole breakaway and<br>non-breakaway|53-54|
Save up to 65% panel space with Bussmann series power distribution fuse blocks
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-1
**8 — Fuse blocks and holders**
## Quick guide
These tables list various fuse classes, sizes and voltages along with their available blocks and holders. Catalog pages are denoted parenthetically "()" next to their catalog symbol. E.g.: BCM603 (8-6) is in Section 8, page 6.
**==> picture [537 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse class/ Catalog Amp DIN—Rail In-line Panel mount Open center<br>size symbol* range Fuse blocks** holders** holders** holders** blocks**<br>**----- End of picture text -----**<br>
|Class CC<br>FNQ-R<br>KTK-R<br>LP-CC|Up to 30<br>BCM603 (8-6)<br>CHCC (8-8)<br>OPM-NG (8-13)<br>OPM-1038 (8-12)|HEY (8-53)<br>HEZ (8-52)|HPF-RR (8-43)<br>HPS-RR (8-45)|—|
|---|---|---|---|---|
|Class G<br>SC|1/2-15<br>BG301 (8-15)<br>—<br>20<br>BG302 (8-15)<br>25-30<br>BG303 (8-15)<br>35-60<br>G30060 (8-15)|HEG (8-49)|HPG-EE (8-44)<br>HPS-EE (8-45)|—|
|||HEH (8-49)|HPS-JJ (8-45)||
|||HEC (8-49)|HPS-FF (8-45)||
|||HEJ (8-49)|—||
|Class J<br>DFJ<br>JKS<br>LPJ|Up to 60<br>JM60030 (8-31)<br>JM60030-_MW_, *** (8-33)<br>JP60030-3 (8-30)<br>CH_J (8-28)<br>JT(N)600_ (8-29)|—|—|—|
||70-400<br>JM60100 (8-31)<br>JM60100-_MW_*** (8-33)<br>—<br>110-200<br>JM60200 (8-31<br>JM60200-_MW_*** (8-33)<br>250-400<br>JM60400 (8-31)<br>JM60400-_MW_*** (8-33)<br>450-600<br>JM60600 (8-31)|||1BS101 (8-39)<br>BH-0111 (8-39)|
|||||—|
|||||BH-3145 (8-39)|
|||||BH-3144 (8-39)|
|250 V<br>Class H/K5<br>NON|Up to 60<br>HM250__ (8-19)<br>HM250__-_MW_*** (8-24)<br>CH14 (8-16)|-—|—|—|
||70-600<br>HM25___ (8-19)||||
|600 V<br>Class H/K5<br>NOS|Up to 60<br>HM600__ (8-19)<br>HM600__0-_-MW_*** (8-24)<br>—<br>70-600<br>HM60___ (8-19)|—|—|—|
|Class L<br>KLU<br>KRP-C<br>KRP-CL<br>KTU|601-1200<br>51215 (1-pole)†<br>51235 (3-pole)†<br>—|—|—|—|
|250 V<br>Class RK1/RK5<br>FRN-R<br>KTN-R<br>KWN-R<br>LPN-RK|Up to 60<br>RM250__ (8-21)<br>RM250__0-_MW_*** (8-26)<br>—<br>70-600<br>RM25___ (8-21)|—|—|—|
|600 V<br>Class RK1/RK5<br>FRS-R<br>KTS-R<br>KWS-R<br>LPS-RK|Up to 60<br>RM600__ (8-21)<br>RM600__-_MW_*** (8-26)<br>—<br>70-600<br>RM60___0 (8-21)|—|—|—|
|300 V Class T<br>JJN|Up to 600<br>T30___ (8-35)<br>—<br>250-400<br>T30400 (8-35)<br>450-600<br>T30600 (8-35)|—|—|—|
||||BH-1133 (8-39)||
||||BH-3144 (8-39)||
|600 V Class T<br>JJS|Up to 60<br>T600__ (8-37)<br>—<br>70-100<br>T60100 (8-37)<br>110-200<br>T60200 (8-37)<br>250-400<br>T60400 (8-37)<br>450-600<br>T60600 (8-37)|—|—|—|
||||BH-0111 (8-39)||
||||BH-1132 (8-39)||
||||BH-1133 (8-39)||
||||BH-3144 (8-39)||
|Supplemental<br>13/32" x 1-1/2"<br>BAF<br>FNM<br>FNQ<br>KLM<br>KTK|Up to 30<br>BMM603 (8-6)<br>3743 (8-14)<br>4421 (8-14)<br>4515 (8-14)<br>CHM (8-8)<br>NDNF1-WH (8-11)<br>OPM-1038 (8-12)<br>OPM-NG (8-13)|HEB (8-51)<br>HEX (8-53)|HPC-D (8-43)<br>HPD (8-44)<br>HPF (8-43)<br>HPG (8-44)<br>HPM (8-44)<br>HPM-D (8-44)<br>HPS2 (8-45)<br>HPS (8-45)|—|
|Supplemental<br>13/32" x 1-3/8"<br>BBS|Up to 30<br>BMM603 (8-6)<br>3743 (8-14)<br>4421 (8-14)<br>4515 (8-14)<br>—|HEH (8-49)|HPS-L (8-45)|—|
Eaton.com/bussmannseries
8-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
**==> picture [537 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse class/ Catalog Amp DIN—Rail In-line Panel mount Open center<br>size symbol* range Fuse blocks** holders** holders** holders** blocks**<br>**----- End of picture text -----**<br>
||||||HHB (8-47)|||
|---|---|---|---|---|---|---|---|
|1/4 x 7/8|AGW|Up to 30|—|—|HM (8-48)<br>HR (8-48)|HJL (8-42)|—|
||||||HRK (8-48)|||
|1/4 x 1|AGX|Up to 30|3828 (8-5)<br>4520 (8-5)<br>4393 (8-5)|—|HHB (8-47)<br>HM (8-48)<br>HR (8-48)<br>HRK (8-48)|HJL (8-42)|—|
||ABC||||HFA (8-46)|||
||AGC||||HFB (8-47)|HKP (8-42)||
|1/4 x 1-1/4|GBB<br>MDA|Up to 30|S-8000 family (8-4)|—|HHB (8-47)<br>HM (8-48)|HTB (8-41)<br>HK (8-42)|—|
||MDL||||HR (8-48)|HLD (8-43)||
||MDQ||||HRK (8-48)|||
||C515|||||||
||C517|||||||
|5x15mm|C518|Up to 7|—|—|HHT (8-46)|—|—|
||C519|||||||
||C520|||||||
||GDA|||||||
||GDB|||||||
||GDC|||||||
||GMA|||||||
||GMC|||||||
|5x20mm|GMD|Up to 15|—|—|HHT (8-46)|HTB (8-41)|—|
||S500|||||||
||S501|||||||
||S505|||||||
||S505H|||||||
||S506|||||||
- Refer to data sheets for applicable fuse voltage and interrupting ratings and agency information.
** Fuse blocks and fused switches are available in a variety of pole and terminal configurations, and voltage and withstand ratings (SCCRs).Refer to data sheets for complete catalog numbers.
- *** This is a UL Listed power distribution fuse block, combining a fuse block and power distribution block into one unit.
- Not shown in this catalog. Contact customer service for details.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-3
**8 — Fuse blocks and holders**
S-8000 bolt-in and snap-in mount open blocks for 1/4" x 1-1/4" fuses
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
Ratings
Volts 300 V Amps 30 A max*
- See catalog number tables for agency limitations.
## Agency information
- UL Recognized, Guide IZLT2, File E14853, CSA Certified Class 6225-01, File 47235, RoHS compliant, CE
## Single pole anti-rotation pin
- Single-pole blocks may be ordered without the anti-rotational pin. Add an “X” to the number of poles, e.g., BK/S-8000-1X.
|Catalogno.†|Poles|Terminal|Terminal<br>angle|Max<br>amps|
|---|---|---|---|---|
|Bolt-in mount|||||
|S-8001-(poles)-R<br>S-8002-(poles)-R||Solder|0°<br>40°|UL 30<br>CSA 21|
|S-8101-(poles)-R<br>S-8102-(poles)-R|1-12|3/16" quick-connect|0°<br>40°|UL 20<br>CSA 13|
|S-8201-(poles)-R<br>S-8202-(poles)-R<br>S-8203-1-R|1|1/4" quick-connect<br>0°<br>40°<br>Side 1/4"quick-connect||UL 30<br>CSA 16|
|S-8301-(poles)-R|1-12|Screw|—|UL 30 A<br>CSA 25A|
|Snap-in mount|||||
|S-8001-1-SNP-R<br>S-8002-1-SNP-R||Solder|0°<br>40°|UL 25<br>CSA 21|
|S-8101-1-SNP-R<br>S-8102-1-SNP-R|1|3/16" quick-connect|0°<br>40°|UL 20<br>CSA 13|
|S-8201-1-SNP-R<br>S-8203-1-SNP-R||1/4" quick-connect|0°<br>Side|UL 20<br>CSA 16|
- Quantities for regular and bulk (BK/ prefix) catalog numbers varies with the number of poles. Contact customer satisfaction team for details.
## Mounting dimensions — in*
|No. of Poles|No. of Poles|No. of Poles<br>A|B|
|---|---|---|---|
|1<br>2<br>3<br>4<br>5||—<br>1-1/8<br>1-3/4<br>2-3/8<br>3|—<br>5/8<br>1-1/4<br>1-7/8<br>2-1/2|
|6||3-5/8|3-1/8|
|7||4-1/4|3-3/4|
|8||4-7/8|4-3/8|
|9||5-1/2|5|
|10||6-1/8|5-5/8|
|11||6-3/4|6-1/4|
|12||7-3/8|6-7/8|
A B
- Block length varies by specific termination and mounting. See data sheet 2101 for details.
Data sheet no. 2101
Eaton.com/bussmannseries
8-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
|3828 open blocks with solder terminals for<br>1/4" x 1" fuses<br>3828<br>Ratings<br>• Volts 250 V<br>• Amps 30 A<br>Catalog no.<br>Poles<br>Base width — in (mm)<br>3828-1<br>1<br>1/2 (12.7)<br>3828-2<br>2<br>1-1/8 (28.6)<br>**2011/65/EU**<br>ESTO emt~~=~~<br>~~RE~~|3828 open blocks with solder terminals for<br>1/4" x 1" fuses<br>3828<br>Ratings<br>• Volts 250 V<br>• Amps 30 A<br>Catalog no.<br>Poles<br>Base width — in (mm)<br>3828-1<br>1<br>1/2 (12.7)<br>3828-2<br>2<br>1-1/8 (28.6)<br>**2011/65/EU**<br>ESTO emt~~=~~<br>~~RE~~|3828 open blocks with solder terminals for<br>1/4" x 1" fuses<br>3828<br>Ratings<br>• Volts 250 V<br>• Amps 30 A<br>Catalog no.<br>Poles<br>Base width — in (mm)<br>3828-1<br>1<br>1/2 (12.7)<br>3828-2<br>2<br>1-1/8 (28.6)<br>**2011/65/EU**<br>ESTO emt~~=~~<br>~~RE~~|3828 open blocks with solder terminals for<br>1/4" x 1" fuses<br>3828<br>Ratings<br>• Volts 250 V<br>• Amps 30 A<br>Catalog no.<br>Poles<br>Base width — in (mm)<br>3828-1<br>1<br>1/2 (12.7)<br>3828-2<br>2<br>1-1/8 (28.6)<br>**2011/65/EU**<br>ESTO emt~~=~~<br>~~RE~~|
|---|---|---|---|
||3828-3|3|1-3/4 (44.5)|
||3828-4|4|2-3/8 (60.3)|
||3828-5|5|3 (76.2)|
||3828-6|6|3 5/8 (92.1)|
||3828-7|7|4-1/4 (108.0)|
||3828-8|8|4-7/8 (123.8)|
||3828-10|10|6-1/8 (155.6)|
||3828-12|12|7-3/8 (187.3)|
Dimensions — in** 1.88 te ~~n~~ a 0.63 ELEY 0.19 1.38 ~~-—~~
4520 and 4393 open blocks with solder terminals for 1/4" x 1" fuses
|Ratings<br> Volts 250 V<br> Amps 30 A<br>Catalog no.<br>4520|Description<br>Integral clip and straight solder terminals<br>**2011/65/EU**<br>~~=:~~|
|---|---|
|4393|Spare fuse block - no terminals|
Ratings
- Volts 250 V
- Amps 30 A
## Dimensions — in*
**==> picture [110 x 66] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.94<br>0.188<br>0.598<br>1.38<br>**----- End of picture text -----**<br>
4520 integral clip and straight solder terminals
**==> picture [128 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.38<br>0.188<br>0.598<br>0 & 2<br>**----- End of picture text -----**<br>
4393 spare fuse block, no terminals
- Mounting screw hole diameter is 0.147". Counterbore 0.636" diameter. Max #6 mounting screw.
** Mounting screw hole diameter is 0.147." Max #6 mounting screw.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-5
**8 — Fuse blocks and holders**
BCM (Class CC) and BMM (supplemental 13/32 x 1-1/2” /10x38mm) modular style fuse blocks with optional covers.
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
The BCM and BMM modular fuse blocks contain features that add versatility, reduce labor and enhance safety of any panel design. Optional IP20 finger-safe covers enhance safety with a lockout/tagout feature along with optional open fuse indication to speed troubleshooting.
## Ratings
- Volts 600 Vac/dc
- Amps 30 A
- SCCR up to 200 kA*
- Limited by fuse interrupting rating
BMM603-3C with CVRI-CCM covers
## Agency information
- Class CC BCM blocks
- UL Listed E14853 - IZLT
- CSA Certified 47235-6225-01
- RoHS Compliant
- 13/32” x 1-1/2” BMM blocks
- UL Recognized, E14853 - IZLT2
- CSA Certified 47235-6225-01
- CE
BCM603-3PQ with pressure plate and 1/4" quick-connect terminals
- RoHS compliant
## Covers*
- Covers are included in the overall UL Listing/Recognition and CSA Certification
- Covers sold separately in multiples of three units. Order one unit per pole.
## Poles
- 1-, 2-, 3-pole units factory assembled
- Single-pole units snap together to create desired number of poles
## Recommended Bussmann series fuses
- Class CC: LP-CC, FNQ-R, KTK-R
- UL 13/32" x 1-1/2": KTK, FNQ, KLM, FNM, BAF
- IEC 10x38mm: C10G, C10M, FWA, FWC
## Recommended DIN-Rail end stops
- Catalog no. BRKT-ND
- Catalog no. BRKT-NDSCRW2
## Features
- Available in 1-, 2- and 3-pole configurations to meet stocking requirements
- Blocks are fully modular with a snap-together design that provides toolless assembly of multiple pole blocks at point-of-use to reduce inventory and save assembly time and labor
- DIN-Rail and panel mount versatility allows one product to be used for multiple applications, lowering inventory cost
- Compact footprint consumes minimal panel space
- Optional see-through cover enhances safety with IP20 finger-safe protection, lockout/tagout capability and open circuit indication
- Easy circuit identification with available universal marker labels for fuse block covers
- Tin-plated bimetallic copper fuse clips deliver superior fatigue resistance compared to traditional spring brass
- Terminal options to meet application needs including 1/4” spade quick-connect terminals for faster panel assembly
## Terminals for 75/90°C Cu and AL wire
|Terminal type|AWG range|AWG|Torque<br>lb-in<br>(N•m)|
|---|---|---|---|
|||Cu 2-3|50 (5.6)|
|||Cu 4-6|45 (5.1)|
|Box lug (C)|Cu 2-14<br>Al 2-8|Cu 8-14<br>Al 2-6|35 (4.0)<br>50 (5.6)|
|||Al 8|40 (4.5)|
|Screw (S)||||
|Screw/quick-connect* (SQ)<br>Pressureplate (P)|Cu 10-18|10-18|20 (2.3)|
|Pressureplate/quick-connect* (PQ)||||
## Flammability ratings
- Blocks UL 94V0, self-extinguishing
- Covers UL 94HB, self-extinguishing
## Operating and storage temperature range
- Blocks -40°C to +120°C
- Non indicating covers -40°C to +120°C
- Indicating covers -20°C to +90°C**
- ** Indication requires minimum 90 V and closed circuit to illuminate.
## Cover catalog numbers
- ¼“ quick-connect terminal maximum amps dependent on female spade connector and wire ratings.
## Recommended covers†
||Cover catalogno.||
|---|---|---|
|Terminal type<br>Box lug (C)|Indicating<br>CVRI-CCM|Non indicating<br>CVR-CCM|
|Screw (S)|CVRI-CCM|CVR-CCM|
|Screw/quick-connect (SQ)|CVRI-CCM-QC|CVR-CCM-QC|
|Pressureplate (P)|CVRI-CCM|CVR-CCM|
|Pressureplate/quick-connect (PQ)|CVRI-CCM-QC|CVR-CCM-QC|
- For use with 4 AWG max conductors.
- For blocks with quick-connect terminals — CVR(I)-CCM-QC
- All other terminal options — CVR(I)-CCM
## Data sheet no. 10241
Eaton.com/bussmannseries
8-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
|Catalogno.|||||||
|---|---|---|---|---|---|---|
|Terminal type|||||||
|10-32 Phil-slot<br>screw|Screw with<br>quick-connect*|Pressureplate|Pressure plate with<br>quick-connect*|Box lug|Poles|Fuse/class|
|BCM603-1S|BCM603-1SQ|BCM603-1P|BCM603-1PQ|BCM603-1C|1|CC|
|BCM603-2S|BCM603-2SQ|BCM603-2P|BCM603-2PQ|BCM603-2C|2|CC|
|BCM603-3S|BCM603-3SQ|BCM603-3P|BCM603-3PQ|BCM603-3C|3|CC|
|—|BMM603-1SQ|—|BMM603-1PQ|BMM603-1C|1|10x38 (13/32”x1-1/2”)|
|—|BMM603-2SQ|—|BMM603-2PQ|BMM603-2C|2|10x38 (13/32”x1-1/2”)|
|—|BMM603-3SQ|—|BMM603-3PQ|BMM603-3C|3|10x38 (13/32”x1-1/2”)|
|—|BCCMM603-3SQ|—|BCCMM603-3PQ|—|3|3-Pole control circuit transformer block 2-pole<br>CC with 1-pole 10x38mm (13/32” x 1-1/2”)|
* 1/4“ quick-connect terminal maximum amps dependent on female spade connector and wire ratings.
## Dimensions — mm (in)
**==> picture [533 x 241] intentionally omitted <==**
**----- Start of picture text -----**<br>
33 21 40 60<br>1.3 .8 1.6 2.4<br>95 77 10<br>3.7 3.0 .4 4<br>.2<br>39<br>59<br>20 20 1.6<br>2.3<br>.8 .8<br>16<br>41 .6 33<br>1.6 1.3<br>**----- End of picture text -----**<br>
Data sheet no. 10241
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-7
## **8 — Fuse blocks and holders**
CH modular, IP20 finger-safe DIN-Rail holders for Class CC, midget and PV fuses
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
Bussmann series CH DIN-Rail fuse holders are for UL Class CC and midget fuses, and IEC 10x38mm fuses. They are available with and without indication in 1-, 2- and 3-pole IP20 finger-safe versions. A variety of accessories extends their application flexibility and they may be ganged together to meet specific application requirements.
## Ratings
- Volts
- 600 V (or less) UL
- 690 V (or less) IEC
- 1000 Vdc (or less) photovoltaic (PV)
- Amps
- 30 A UL
- 32 A IEC
- SCCR
- 33 kA photovoltaic
- 200 kA RMS Sym. (CHCC, CHM*)
- CHM SCCR is fuse interrupting rating dependent.
## Agency information
- CHCC, CHM; UL Listed Guide IZLT, Recognized Guide IZLT2, File E14853
- CHPV, UL Listed to 4248-19, Guide IZMR, File E348242
- CSA File 47235, CHPV and CHM - Class 6225-30, CHCC - Class 6225-01
- IEC 60269-2 (CHM, CHPV)
- CCC
- RoHS compliant
- CE
## Mounting: 35mm DIN-Rail
## Wire range
- 75°C and 90°C Cu
- 18-4 AWG (0.8-21.1mm[2] )
- Solid, stranded and fine stranded*
- See data sheet 10430 for application details.
## Flammability
- UL 94V0, self-extinguishing
## Storage and operating temperature
- -4°F (-20°C) to +194°F (90°C) indicating
- -4°F (-20°C) to +248°F (120°C) non-indicating
## Features
- High SCCR rated, UL Listed Class CC holder with optional open fuse indication for 600 V and 48 Vdc (see catalog number table for details)
- Enhanced safety with IP20 finger-safe construction
- UL Recognized midget and IEC 10x38mm holders with factory assembled neutral pole option
- Agency ratings up to 1000 Vdc for use with PV fuses.
- Available remote PLC fuse indication module
- Wiring flexibility with terminals rated for use with 75°C or 90°C solid, stranded and fine stranded wire, and fork terminals and comb busbars. (Use any higher temperature insulations at the 90°C ampacity with appropriate derating.)
- Complete range of UL Listed and high SCCR rated one- and threephase finger-safe comb busbars and power feed lugs
- Optional hex head terminal screw makes it easier to achieve necessary torque values
**==> picture [260 x 226] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse access door Optional open IP20 finger-safe<br>accommodates 4mm fuse indicator construction<br>lockout/tagout device<br>Captive phil-slot or<br>optional hex head<br>terminal screw<br>Fork lug<br>terminal<br>Toolless<br>ganging for<br>multiple poles<br>Dual conductor<br>Toolless 35mm rated box lug<br>DIN-Rail Wire strip terminal<br>mounting gauge<br>**----- End of picture text -----**<br>
## Terminals
- Single or dual conductors
- Comb busbar
- Terminal screws
- Standard phil-slot
- Optional hex head (order by adding “-H” suffix to the catalog number, e.g., CHM1DU-H)
## Torque
- 30 lb-in (3.4 N•m) maximum
## Data sheet no. 10430
Gang multiple poles to meet application requirements using kit catalog number JV-L (gangs up to four poles).
Eaton.com/bussmannseries
8-8 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## UL midget and IEC 10x38
|Catalogno.†<br>With indication*|Without indication|Volts and am<br>UL|Volts and amps<br>IEC|Agencymarks|Poles|SCCR|Recommended<br>Bussmann series fuses|
|---|---|---|---|---|---|---|---|
|CHM1DIU<br>CHM2DIU|CHM1DU<br>CHM2DU|||UR, CSA,<br>IEC 60269-2,|1<br>2<br>~~—~~|||
|CHM3DIU|CHM3DU|600 V/|690 V/|CCC|3||BAF, BAN,|
|CHM4DIU<br>CHM1DNIU<br>CHM3DNIU|CHM4DU<br>CHM1DNU<br>CHM3DNU|30 A|32 A|IEC 60269-2|4<br>1 + neutral<br>3 + neutral|200 kA<br>RMS Sym.††|FNM, FNQ,<br>FWA, FWC,<br>KLM, KTK,<br>AGU, C10G_, C10M_|
|CHM1DI-48U|—|48 Vdc/<br>30 A|48 Vdc/<br>32 A|UR, CSA,<br>IEC 60269-2,<br>CCC|1|||
|—|CHM1DNXU|—|690 V/<br>32 A|IEC 60269-2||N/A|N/A|
|CHM1DCIU|CHM1DCU||||1||600/690 V|
|CHM2DCIU|CHM2DCU||||2||BAF, BAN,|
||||||||FNM, FNQ,|
|CHM3DCIU|CHM3DCU|600 Vac,<br>1000 Vdc,<br>30 A|1000 Vdc,<br>690 V,<br>32 A|UR, CSA,<br>IEC 60269-2|3|200 kA<br>RMS Sym.††<br>33 kA DC|FWA, FWC,<br>KLM, KTK,<br>AGU, C10G_, C10M_,|
|CHM4DCIU|CHM4DCU||||4||1000 Vdc|
||||||||PV-(amp)A10F,|
||||||||PV10M-(amp)|
UL Class CC
Catalog no. † Recommended op ~~eee~~ With indication* Without indication Volts / amps Agency marks Poles SCCR Bussmann series fuses CHCC1DIU CHCC1DU 1 CHCC2DIU CHCC2DU 600 V/30 A 2 200 kA LP-CC, ~~————~~ CHCC3DIU CHCC3DU UL, CSA, CCC ~~—~~ 3 RMS Sym. FNQ-R, KTK-R CHCC1DI-48U — 48 Vdc/30 A 1 33 kA DC
## UL and IEC photovoltaic
|Catalogno.†<br>With indication*|Without indication|Volts/amps|Agencymarks|Poles|SCCR|Recommended<br>Bussmann series fuses|
|---|---|---|---|---|---|---|
|CHPV1IU<br>CHPV2IU|CHPV1U<br>CHPV2U|1000 Vdc/30 A|UL, CSA, , UL<br>4248-18, IEC<br>60269-1,CCC|1<br>2|33 kA DC|PV-(amp)A10F,<br>PV10M-(amp)|
- Available with optional hex head terminal screws. To order, add “-H” suffix to the desired catalog number.
- †† SCCR is limited to the interrupting rating of the installed fuse or 200 kA, which ever is less.
- All models require 90 V minimum for illumination, except CHM1DI-48U that requires 15 V minimum.
Dimensions — mm (in)
**==> picture [459 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
70 (2.756)<br>52.5 (2.067)<br>35 (1.378)<br>61.83 (2.434) 17.5<br>(0689)<br>18.59<br>(0.732)<br>73.88<br>(2.909)<br>9<br>| ISIS (0.354) Re<br>IS |)ESSE Im<br>7<br>42.58 (1.676) (0.276)<br>52.83 (2.08)<br>83.19 (3.275)<br>**----- End of picture text -----**<br>
Data sheet no. 10430
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-9
## **8 — Fuse blocks and holders**
## Accessories
## Power feed terminals
PWR1PLP — Single-phase, low profile power feed terminal
**==> picture [89 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power feed terminals<br>1- and 3-phase comb busbars<br>Contact safety covers<br>**----- End of picture text -----**<br>
## Ratings
- Volts 1000 V
- Amps 115 A
- Wire range 1/0-10 AWG Cu, max torque 50 lb-in (5.6 N•m)
- Wire rating 60°C[†]
PWR35MM — 35mm[2] three-phase power feed terminal for threephase busbars
## Ratings
- Volts 1000 V
- Amps 115 A
- Wire range 1/0-10 AWG Cu, max torque 50 lb-in (5.6 N•m)
- Wire rating 60°C[†]
## Comb busbars
- Easily distribute power in single-or three-phase systems
- Flexible cut-to-length busbars do not compromise the finger-safe protection (requires using endcaps)
- 100 kA SCCR when protected by a max 200 A Class J fuse
- Single-phase busbars rated to 1000 Vdc and 100 A
- Three-phase busbars rated to 600 V and 100 A
- Power feed terminals for single-and three-phase systems
PWR50MM — 50mm[2] direct feed power terminal
## Ratings
- Volts 1000 V
- Amps 115 A
- Wire range 1-14 AWG Cu, max torque 35 lb-in (3.9 N•m)
- Wire rating 75°C[†]
- Higher temperature rated wire may be used with appropriate derating.
## Agency information
- UL 508, File E195399
## Pitch 17.8mm
## Ratings
- Volts
- 600 V max. (three-phase)
- 1000 Vdc/600 Vac max. (single-phase)
- Amps 100 A max.
- SCCR
- 10 kA (default)
- 100 kA (with upstream Class J max 200 A fuses)
|Catalogno.|Phase|No. ofpins|Endcaps*|
|---|---|---|---|
|BB1P100M3||3||
|BB1P100M6<br>BB1P100M9<br>~~a~~||Yes*<br>6<br>9<br>~~oe~~||
|BB1P100M12|Single|12||
|BB1P100M15||15||
|BB1P100M57||57pin cuttable|No**|
|BB3P100M6||6||
|BB3P100M9||9||
||||Yes*|
|BB3P100M12|Three|12||
|BB3P100M15||15||
|BB3P100M57||57pin cuttable|No**|
## Comb busbar safety covers and end caps
## FSCVR
Spare comb busbar pin safety protection covers (used to cover exposed pins on comb busbars). Sold in quantity of ten strips of five covers each. (FSCVR comes with five covers on a strip. Minimum order is 10 strips or 50 safety covers total.)
## ECAP1P
End cap for single-phase comb busbars. Sold in quantity of fifty.
## ECAPMP
End cap for three-phase comb busbars. Sold in quantity of fifty.
## Accessory catalog numbers
|Catalogno.|Description|Cartonquantity|
|---|---|---|
|PWR1PLP|Single-phase low-profile power feed<br>terminal (115 A, 1000 V)|10|
|PWR35MM|35mm2power feed terminal for<br>three-phase busbar (115 A, 1000 V)|10|
|PWR50MM|50mm2direct power feed terminal<br>(1000 V)|10|
|ECAP1P|Single-phase busbar endcap|50|
|ECAPMP|Three-phase comb busbar end cap|50|
|FSCVR|Spare comb busbar pin safety<br>protection covers|10 strips of five<br>covers each, total<br>50 individual covers|
- With endcaps assembled. If cut to length, order additional endcaps separately.
- ** Order end caps separately, ECAP1P for single-phase busbars and ECAPMP for three-phase busbars.
Data sheet no. 10430
Eaton.com/bussmannseries
8-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## PLC fuse monitor
Flammability rating UL 94V0
Local indication
## Catalog no. CH-PLC2
The Bussmann series resettable PLC fuse monitor permits easy integration with a Programmable Logic Controller (PLC) or other monitoring and control equipment. Signals up to three-phases. Includes 0.11" (2.8mm) quick-connects for power, signal and ground connections.
## Ratings
- Signal output to PLC*
- +24 Vdc, 10 mA max
- Output signals
- Digital 0 Vdc (low), 24 Vdc max (high)
- 0 Vdc Low – fuse is good
- 24 Vdc High – fuse has opened
- When the fuse opens, the output signal is sent high and will remain high until the unit is reset.
## Agency information
- Two distinct LEDs indicate unit power (green) and open fuse (red). Open fuse LED is resettable upon fuse replacement and the actuating the reset switch
## Wiring
- For power, signal and ground connections use shielded twisted pair 22-24 AWG (0.34-0.25mm[2] ) 300 V rated wire.
## Minimum circuit voltage
- Minimum circuit voltage required across the CH holder is 100 Vac for the remote indication device to operate
## Installation
- Mounts on the left side of the fuse holder and mechanically interlocks with the fuse holder switch handle with hardware provided
Degree of protection IP20 finger-safe
- UL 508 Listed, Guide NKCR, File E170168
- cULus, Guide NKCR7, File E170168 to Canadian Standard 22.2, No. 14-13
Storage and operating temperature
- -4°F (-20°C) to +167°F (+75°C)
Emissions and immunity testing
- IEC 60947-1: Voltage Switchgear and Control Gear
- IEC 61000-6-2: Electromagnetic Compatibility (EMC)
- IEC 61000-4-2: Electrostatic Discharge Immunity - Test at level 3 (6 kV-Contact Discharge) and level 2 (4 kV-Air Discharge)
- IEC 61000-4-3: Electromagnetic Compatibility - Radiated, Radiofrequency, Electromagnetic Field Immunity test at level x (20 V/m)
- IEC 61000-4-4: Electromagnetic Compatibility - Testing and Measurement Techniques at level 3 (± 2kV - Power Port and ±1 kV - I/O Ports)
- IEC 61000-4-5: Electromagnetic Compatibility - Surge Immunity test at level 4 (±4 kV)
PLC programming
- The CH-PLC2 signal line is designed to provide a digital input to a PLC I/O card
- Programmable Logic Control program must be written to properly interpret the input signal to the PLC
- The PLC program should check for consecutive high signals before taking action on a critical process
## To order
- Specify catalog number CH-PLC2 (one unit)
- Data sheet no. 10430
- IEC 61000-4-6: Immunity to Conducted Disturbances at level 3 (10 V)
NDNF1-WH single-pole DIN-Rail mount fuse holding terminal block for 13/32" x 1-1/2" (10x38mm) fuses
Ratings: 600 volts / 30 amps
Wire range 8-22 AWG Cu
Torque rating 2.03 N•m (18 lb-in)
Mounting 35mm DIN-Rail or C-rail
Fuse pullers
- PF1-WH (white)
- PF1-BK (black)
Max operating temperature 105°C
Circuit jumper catalog no. JF1 for 2 circuits
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-11
## **8 — Fuse blocks and holders**
## Optima™ fuse holder module and module with disconnect switch
OPM-1038(R)(C) without switch OPM-1038(R)SW(C) with switch
OPM-1038(R)(C) is a 3-pole modular fuse holder 13/32" x 1-1/2" (10x38mm) and Class CC fuses.
OPM-1038(R)SW(C)* is a 3-pole load break modular fuse holder and disconnect switch for 13/32" x 1-1/2" (10x38mm) and Class CC fuses.
Both the OPM-1038(R)SW(C) and OPM-1038(R) (C) are available with optional communications for interfacing with programmable logic controllers.
- Recommend using the UL 98 Listed CCP2 disconnect switch. See page 11-2.
## Features
- Padlockable with finger-safe terminals for safety. Qualified as IP20 per IEC 60529
- Cam-action handle for easy fuse module removal, offered with Class CC rejection clips or 13/32 x 1-1/2 (10x38mm) clips to meet global needs
- Wire ready with 35mm DIN-Rail or screw panel mounting (#8 screw, 1-1/4” long) saves installation time
- Fuse indication lights with optional communications for remote fuse status available. See data sheet for additional wiring details.
## Typical applications
- Industrial control
- Process control systems
- Automated warehouse systems
- Individual control circuits
## Ratings
## Dimensions — in (mm)
- See catalog numbers table
0.57 (15)
**==> picture [533 x 434] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.22 (82)<br>Agency information 2T1 Counication<br>4T2 IL1 port<br>See catalog numbers table 3.74(95) ZA) 3.17(81) t 1.76(45)6T3 ae 3L25L3 0.740.27 (19)(7)<br>1.65 0.31 (8)<br>Flammability rating UL 94V0 (42) 0.23 (6) 0.50 (13) 3.6 (91)<br>0.41 (11)<br>OPM-1038(R)SW(C) switch horsepower ratings 0.224(6) 1.312(33) 3.60(91) 1.86(47) Counicationport<br>pS Panel mount Panel mount<br>hole pattern hole pattern<br>3-phase volts 240 480 600 OPM-1038<br>Ps = * 0.57 (15)<br>HP 5 10 15<br>Recommended Bussmann series fuses<br>3.74<br>Class CC; LP-CC, FNQ-R, KTK-R 3.17 (95) Counicationport<br>|| (81) [1] 84 |<br>UL 13/32" x 1-1/2"; KTK, FNQ, KLM, FNM, BAF 0.23 (6) 0.50<br>(13)<br>IEC 10x38mm; C10G, C10M, FWA, FWC 0.44<br>1.86 (11)<br>0.224 1.312 (47)<br>Physical characteristics (6) eo Panel mountinghole pattern(33) = 3.60Panel mountinghole pattern [(91)] _<br>Small size matches 45mm IEC starter width 5.72 (145)<br>4.25 (108)<br>Counication<br>Accepts Cu AWG stranded 8-18 and solid 10-18 wireOPM-1038(R)SW(C ) switch version requires a handle and shaft for 1.38(35) oe 0.43(11) 2T14T 26T3 1L13L2 0.27port(7) 1.76(45)<br>through the door operation 5L3 0.74 (19)<br>OPM-1038SW ee GD BS 0.31(8) |<br>Catalog no.<br>Without With<br>communication communication Fuse type/size Volts Amps SCCR Agency information<br>OPM with disconnect switch<br>UL 508 Recognized, Guide NLRV2, File E161278,<br>OPM-1038SW OPM-1038SWC* Non-rejection, 13/32” x 1-1/2 600 Vac UL/CSA, 30 A UL, ** CSA Certified, C22.2 No. 39, Class 6225-01, File<br>or 10x38mm 660 V IEC 32 A IEC<br>47235, IEC 60947-3, CE<br>UL 508 Listed, Guide NLRV, File E161278, CSA<br>OPM-1038RSW OPM-1038RSWC* Class CC 600 Vac UL/CSA 30 A 100 kA Certified, C22.2 No. 39, Class 6225-01, File<br>47235,IEC 60947-3, CE<br>OPM without switch<br>UL Recognized, Guide IZLT2, File E114853, CSA<br>OPM-1038 OPM-1038C* Non-rejection, 13/32” x 1-1/2 600 Vac UL/CSA, 30 A UL, ** Certified, C22.2 No. 39, Class 6225-01, File 47235,<br>or 10x38mm 660 V IEC 32 A IEC<br>IEC 60269-2-1, CE<br>UL Listed, Guide IZLT2, File E114853, CSA Certified,<br>OPM-1038R OPM-1038RC* Class CC 600 Vac UL/CSA 30 A 200 kA C22.2 No. 39, Class 6225-01, File 47235, IEC 60269-<br>2-1, CE<br>BUSS<br>BUSS<br>**----- End of picture text -----**<br>
Agency information
- See catalog numbers table
Flammability rating UL 94V0
OPM-1038(R)SW(C) switch horsepower ratings
3-phase volts 240 480 600 ~~Ps~~ HP 5 10 15
Recommended Bussmann series fuses
- Class CC; LP-CC, FNQ-R, KTK-R
- UL 13/32" x 1-1/2"; KTK, FNQ, KLM, FNM, BAF
- IEC 10x38mm; C10G, C10M, FWA, FWC
## Physical characteristics
- Small size matches 45mm IEC starter width
-
- OPM-1038(R)SW(C ) switch version requires a handle and shaft for through the door operation
- With communication not CE.
- ** Rating varies depending on fuse used in module; 10 kA default, higher SCCR requires testing and certification.
Data sheets no. 1002 (OPM-1038) and 1103 (OPM-1038SW)
Eaton.com/bussmannseries
8-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## OPM-NG Optima three-pole overcurrent protection module
The OPM-NG is a 3-pole protection module that's available in versions for Class CC, and UL 13/32" x 1-1/2" supplemental and 10x38mm IEC fuses.
## Catalog numbers
- OPM-NG-SC3 (Class CC)
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- OPM-NG-SM3 (UL/IEC)
Ratings
- Volts
- 600 Vac (or less) UL and CSA
Fuse holder AWG wire range (75°C Cu only)*
- 18-12, single/dual, torque 15 lb-in (1.7 N•m)
- 10-8, single/dual, torque 20 lb-in (2.2 N•m)
- Dual wire with same gauge and type
Input power terminal wire range (AWG)
|Wire|AWG (mm2) range<br>Torque lb-in (N•m)<br>Connector|Torque lb-in (N•m)<br>Screw clamp|
|---|---|---|
|Solid<br>Stranded|Single 14-2 (1.5-25)<br>20 (2.2)<br>Dual 14-6 (1.5-10)<br>Single 14-2 (1.5-25)|15 (1.7)|
||Dual 12-6 (2.5-10)||
## Flammability rating
- UL V2
- 690 Vac (or less) IEC
- Amps
Dimensions — mm (in)
- 30 A UL and CSA
- 32 A IEC
- SCCR
- 200 kA Class CC
- UL supplemental and IEC same as fuse IR up to 200 kA max
## Agency information
- UL; OPM-NG-SC3 UL Listed, UL 4248, File E14853, Guide IZLT. OPM-NG-SM3, UL Recognized, UL 4248, File E14853, Guide IZLT2. CSA Certified, C22.2 No. 4248, Class 6225-01, File 47235. IEC 60947-3 Utilization Category AC20B, CE
## Recommended Bussmann series fuses
- Class CC: LP-CC, FNQ-R, KTK-R
- UL 13/32" x 1-1/2": KTK, FNQ, KLM, FNM, BAF
- IEC 10x38mm: C10G, C10M, FWA, FWC
## Features
- 45mm width matches IEC starters
- 35mm DIN-Rail or panel mount. Max. screw size #8 (M4).
- Pressure plate terminations with dual-wire rated terminals (see wire table) and optional auxiliary contacts
- Integrated collapsible handle and fuse carrier cannot be removed from holder base
- Padlockable and IP20 finger-safe to IEC 60529
## Typical applications
- Mass produced control systems
- Process control systems
- Automated warehouse systems
- Individual control circuits
Data sheet no. 1109
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-13
**8 — Fuse blocks and holders**
3743 open, add-on block for 13/32" x 1-1/2" (10x38mm) fuses
4421 and 4515 open single pole blocks for 13/32" x 1-1/2" (10x38mm) fuses.
Single pole blocks lock into each other and can be added at any time. Each has a single end barrier.
## Ratings
- Volts 250 V **2011/65/EU**
- Amps 30 A
Ratings **2011/65/EU** 3743 open, add-on block Agency information 4421 solder terminal Volts 600 V • CE Amps 30 A Agency information • UL Recognized, Guide IZLT2, a Riza 4515 screw terminal File E14853, CE 3742 end barrier only Catalog no. Terminals Base width ~~—~~ Catalog no. Description ~~ee~~ 4421 Solder 5/8" (16mm) 3743 Add-on fuse block 4515 Screw 3/4" (19mm) 3742 End barrier 3723 Block and end barrier marking strip (length 9-3/8") Dimensions — in* ~~eea~~
Catalog no. Terminals Base width ~~ee~~ 4421 Solder 5/8" (16mm) 4515 Screw 3/4" (19mm) Dimensions — in* ~~a~~ 2.5 0.897 0.19 1.63 4421 solder terminals e ~~e~~ 2.56 0.897 0.19
Dimensions — in*
**==> picture [173 x 123] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.56 0.323<br>1.125 0.25<br>a Pn 0.78<br>0.144<br>B L E) al, 1.34<br>1.29<br>3 7 4 2 1.125 0.84<br>—— 2.56 0.25 = 0.50<br>**----- End of picture text -----**<br>
## 4515 with screw terminals
* Mounting screw hole diameter 0.147" (3.7mm). Counterbore diameter 0.636"
- (8mm). Max. #6 mounting screw.
- Mounting screw hole diameter 0.147". Counterbore diameter 0.312". Max. #6 mounting screw.
Data sheet no. 2104
Eaton.com/bussmannseries
8-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## BG and G Class G fuse blocks
Bussmann series open style BG and G fuse blocks are available in 1-, 2- and 3-pole configurations and offer a variety of terminal options.
## Ratings
- Volts
- 600 V (0-20 A)
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- 480 V (25-60 A)
- Amps up to 60 A
- SCCR 100 kA RMS Sym.
Agency information
- UL Listed, 4248-5, Guide IZLT, File E14853
- 1-60 A CSA Certified, C22.2 No. 39, Class 6225-01, File 47235
- RoHS compliant
Mounting
- Panel
- DIN-Rail with DRA-1 adapter
|Catalog no./terminal||
|---|---|
|Amps<br>Poles<br>Screw<br>w/ quick-<br>connect*<br>Pressure<br>plate w/<br>quick-<br>connect*<br>Box lug<br>Box lug w/<br>retaining<br>clip||
|BG3011SQ<br>BG3011PQ<br>BG3011B<br>—<br>1||
|Up to 15<br>BG3012SQ<br>BG3012PQ<br>BG3012B<br>—<br>2<br>BG3013SQ<br>BG3013PQ<br>BG3013B<br>—<br>3||
|20<br>BG3021SQ<br>BG3021PQ<br>BG3021B<br>—<br>1<br>BG3022SQ<br>BG3022PQ<br>BG3022B<br>—<br>2<br>~~EE~~||
|BG3023SQ<br>BG3023PQ<br>BG3023B<br>—<br>3||
|BG3031S<br>BG3031P<br>BG3031B<br>—<br>1||
|25-30<br>BG3032S<br>BG3032P<br>BG3032B<br>—<br>2||
|BG3033S<br>BG3033P<br>BG3033B<br>—<br>3<br>35-60<br>—<br>—<br>—<br>G30060-1CR<br>1<br>—<br>—<br>—<br>G30060-2CR<br>2<br>—<br>—<br>G30060-3C**<br>G30060-3CR<br>3<br>AWG<br>wire<br>range/<br>10-14 Cu<br>10-18 Cu<br>6-14 Cu (1-30 A)<br>2-14 Cu (35-60 A)<br>2-8 Al (35-60 A)<br>2-14 Cu<br>2-8 Al<br>~~OO~~<br>~~—_,_.__£{__—+{_—+_—~~<br>~~Oe~~||
|type||
## Dimensions — in
## **1-30 A**
**==> picture [240 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.53<br>1.22<br>0.36 0.425 0.425<br>0.36<br>HMGNeTeNee)<br>3 0.2<br>1.5<br>0.86<br>0.765 2.38<br>1.63 0.169 x 0.210<br>**----- End of picture text -----**<br>
## **35-60 A**
**==> picture [243 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.38 0.22 0.5 0.47 0.84<br>He<br>0.29 Dia. hole<br>0.38 C'bore<br>4.25<br>00 oe<br>2.125<br>0.94<br>fea 4<___» 1.78 }<br>**----- End of picture text -----**<br>
## **35-60 A 3-Pole G30060-3C and G30060-3CR**
**==> picture [231 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.41 1.69<br>0.53<br>lal lialiiall<br>0.22 Dia. hole<br>3.56<br>1.78<br>eeFSUISITUSI|<br>2.75<br>=<br>**----- End of picture text -----**<br>
- Quick-connect rated 20 A max.
- ** Not RoHS compliant.
Accessories
~~ee~~ Catalog no.[†] Description Color PF1-WH White Fuse cover/puller PF1-BK Black
- Order one cover per pole.
Data sheet no. 1106
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-15
**8 — Fuse blocks and holders** 10,
## CH14 modular fuse holders for 14x51mm fuses
Bussmann series 14x51mm modular fuse holders are suitable for use with standard cylindrical fuses and high speed FW type ferrule fuses. With DIN-Rail or panel mount flexibility, their compact dimensions helps reduce space, allows for higher cable bending radius. Low watts loss and wide range of accessories make them ideally suited for most industrial applications.
## Ratings
- Volts **2011/65/EU**
- 690 Vac/750 Vdc (IEC)
- 700 Vac (UL)
- Amps
- 50 A
- SCCR
- 120 kA AC
- 10 kA DC (PV only)
- Power acceptance
**==> picture [99 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shown with optional microswitch<br>**----- End of picture text -----**<br>
- 5 W to IEC 60269-2 (rated)
- 6.2 W (max)
- Rated impulse withstand voltage (Uimp)
- 6 kV
- Microswitch (IEC)
- 250 Vac / 5 A
## Agency information
|Catalog no.<br>Poles<br>Description<br>UL/IEC holders<br>~~Le~~|Catalog no.<br>Poles<br>Description<br>UL/IEC holders<br>~~Le~~|Catalog no.<br>Poles<br>Description<br>UL/IEC holders<br>~~Le~~|
|---|---|---|
|CH141DNXU<br>CH141DU|1<br>1|Neutral holder|
|CH142DU<br>CH143DU|2<br>3|Fuse holder|
|CH144DU|4||
|CH141DNU|2|1-pole holder+ neutral|
|CH143DNU|4|3-pole holder+ neutral|
|CH141DIU|1||
|CH142DIU<br>CH143DIU|2<br>3|Fuse holder with neon indicator|
|CH144DIU|4||
|CH141DNIU|2|1-pole holder + neutral + neon indicator|
|CH143DNIU|4|3-pole holder + neutral + neon indicator|
|CH141DMSU-F<br>CH143DMSU-F|1<br>3|Holder + microswitch|
|CH143DNMSU-F|4|3-pole holder+ neutral + microswitch|
|CHPV141DI-48U|1|Holder with LED indicator|
|1500 Vdc photovoltaic holders|||
|CHPV141U|1|Holder|
|CHPV141IU|1|Holder with neon indicator|
|CHPV142U|2|Holder|
|CHPV142IU|2|Holder with neon indicator|
- IEC 60269-1 and 2, UL Listed File E14853, CCC (UL/IEC)
- IEC 60269-1 and 2, UL Listed File E348242, CCC (PV)
- RoHS compliant
## Poles
1 to 4
## Protection index
## Accessories
|Catalogno.|Description|
|---|---|
|JV-L<br>CH14-SPS|Multi-pole connector kit; one kitgangs upto 4poles<br>Microswitch for CH141D(I)U; 1 NO + 1 NC changeover type|
|CH14-TPS|Microswitch for CH143D(I)U; 1 NO + 1 NC changeover type|
|CH14-CTP|IP20 protection accessory for terminals with 10mm2or less<br>cable|
- IP20
## Temperature range
- Storage
- -40°C to +80°C (CH14D)
- -20°C to +90°C (CHPV14 indicating)
- -20°C to +120°C (CHPV14 non-indicating)
- Operating
- -20°C to +70°C (CH14D)
- -20°C to +90°C (CHPV14 indicating)
- -20°C to +120°C (CHPV14 non-indicating)
## Features
- Ventilation zones optimized for better heat dissipation
- Built-in padlocking facility and IP20 degree of protection
- Photovoltaic version rated at 1500 Vdc (IEC only) for use with gPV fuses
Data sheet no. 10080
Eaton.com/bussmannseries
8-16
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
## **Fuse blocks and holders — 8**
## CH22 modular fuse holders for 22x58mm fuses
Bussmann series 22x58mm modular fuse holders are suitable for use with standard cylindrical fuses and high speed FW type ferrule fuses. Their compact dimensions help reduce space and allow for higher cable bending radius. Low watts loss and wide range of accessories make them ideally suited for most industrial applications.
## Ratings
- Volts **2011/65/EU**
- 690 Vac/1000 Vdc (IEC)
- 700 Vac (UL)
- Amps
- 125 A (IEC)
- 100 A (UL)
- SCCR
- 120 kA AC
- 50 kA DC
- Power acceptance
- 9.5 W to IEC 60269-2
- Rated impulse withstand voltage (Uimp)
- 6 kV
- Microswitch (IEC)
- 250 Vac / 5 A
## Agency information
- IEC 60269-1 and 2, UL Listed File E14853, CCC, RoHS compliant
|Catalog no.|Poles|Description|
|---|---|---|
|CH221DNXU|1|Neutral holder|
|CH221DU<br>CH222DU|1<br>2|Fuse holder|
|CH223DU|3||
|CH224DU|4||
|CH221DIU|1||
|CH222DIU|2||
|||Holder with neon indicator|
|CH223DIU|3||
|CH224DIU|4||
|CH221DNU|2|1-pole holder + neutral|
|CH223DNU|4|3-pole holder + neutral|
|CH221DNIU|2|1-pole holder+ neutral + neon indicator|
|CH223DNIU|4|3-pole holder+ neutral + neon indicator|
|CH221DMSU-F|1|Holder with microswitch (pre-breaking/fuse<br>operation)|
|CH223DMSU-F|3|3-pole holder + microswitch (pre-breaking/<br>fuse operation)|
|CH223DNMSU-F|3|3-pole holder + neutral + microswitch (pre-<br>breaking/fuse operation)|
|CH221DI-48U|1|1-pole holder with LED Indicator|
## Accessories
|Catalogno.|Description|
|---|---|
|JV-L|Multi-pole connector kit; one kitgangs upto 4poles|
|CH22-SPS|Microswitch for CH221D(I)U; 1 NO + 1 NC changeover type|
|CH22-TPS|Microswitch for CH223D(I)U; 1 NO + 1 NC changeover type|
|CH22-CTP|IP20 protection accessory for terminals with 10mm2or less<br>cable|
## Poles
1 to 4
## Protection index
- IP20 Finger-safe*
- Available protection accessory CH22-CTP for use with conductors of 10mm[2] or less
Wire size (Cu only)
- 2.5-70mm[2]
## Temperature range
- Storage -40°C to +80°C
- Operating -20°C to +70°C
## Features
- Compact dimensions
- Ventilation zones optimized for a better heat dissipation
- Built-in padlocking facility
- IP20 degree of protection
- Flexibility to mount on DIN Rail and screw mounting
- Toolless DIN-Rail mounting, improves ease of use and reduces installation time and costs
Data sheet no. 10115
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-17
**8 — Fuse blocks and holders**
JM70100 700 V modular fuse blocks and modular power distribution fuse blocks for 22x58mm IEC fuses
**==> picture [34 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>Fuses not<br>included.<br>**----- End of picture text -----**<br>
The patented JM70100 fuse block products are available for 22x58mm gG, aM and select high speed fuses as either a fuse block or power distribution fuse block. The power distribution fuse blocks eliminate the need for a separate power distribution block, and require up to 78 percent less panel space while reducing installation time and labor by an average of 36 percent.
All blocks are equipped with a fuse clip reinforcing spring to minimize temperature rise while maintaining reliable surface contact between the fuse and clip over the block's service life.
Rated for applications up to 700 V and 100 amps, their modular design allows for assembly of multiple pole configurations at the point of use. These blocks can also be ordered as factory configured 2- and 3-pole versions.
The versatile 35mm DIN-rail or panel mount capability allows using the same block for multiple applications and reducing inventory cost.
Optional IP20 finger-safe covers enhance electrical safety with a lockout/tagout feature and can be ordered with or without open fuse indication to speed troubleshooting.
The high 200 kA SCCR rating helps achieve a higher assembly short-circuit current rating (SCCR) for compliance with NEC[®] sections 110.10, 409.110(4), 409.22, 440.4(B), 670.3(A)(4) and 670.5.
Easy circuit identification with available universal labels for blocks and covers.
## Fuse class
## Ratings
- Volts 700 V
- Amps 100 A
- SCCR 200 kA RMS Sym.
## Agency information
- Blocks; UL Recognized, Guide IZLT2, File E14853, CSA Component acceptance 47235 — 6225-01
- Covers UL Listed, Guide JDVS, File E58836
- RoHS compliant
## Poles
- 1-, 2-, 3-pole
- Single-pole units snap together to create desired number of poles
## Flammability ratings
- Blocks: UL 94V0, self-extinguishing
- Covers: UL 94HB, self-extinguishing
## Operating and storage temperature range
- Blocks -40°C to +120°C
- Covers; Non-indicating -40°C to +120°C, Indicating -20°C to +90°C
## Conductors
- 75°C Cu/Al*
- Conductors with higher temperature rating may be used, but at their 75°C ampacity.
## Accessories
- IEC 22x58mm gG, gL, aM and aR and gR high speed fuses
- Optional IP20 finger-safe covers in indicating and non-indicating versions. Order one for each pole
|Catalog no.|Optional<br>covers*|Fuse amp<br>range|Poles|Lineside conductors and torque<br>Conductors<br>Size (AWG)|Lineside conductors and torque<br>Conductors<br>Size (AWG)|N•m (lb-in)|Loadside conductors and torque<br>Conductors<br>Size (AWG)|Loadside conductors and torque<br>Conductors<br>Size (AWG)|N•m (lb-in)|
|---|---|---|---|---|---|---|---|---|---|
|Fuse blocks||||||||||
|JM70100-1CR|||1||2-3|5.6 (50)||2-3|5.6 (50)|
|JM70100-2CR<br>JM70100-3CR|CVR-J-60060<br>CVRI-J-60060**|Up to 100|2<br>3|Cu 2-14<br>Al 2-8|4-6<br>8<br>10-14|5.1 (45)<br>4.5 (40)<br>4.0 (35)|Cu 2-14<br>Al 2-8|4-6<br>8<br>10-14|5.1 (45)<br>4.5 (40)<br>4.0 (35)|
|Power distribution fuse blocks|Power distribution fuse blocks|||||||||
|JM70100-1MW14|||1||2-3|5.6 (50)||Cu (1) 8|3.4 (30)|
|JM70100-2MW14<br>JM70100-3MW14|CVR-J-60060<br>CVRI-J-60060**|Up to 100|2<br>3|Cu 2-14<br>Al 2-8|4-6<br>8|5.1 (45)<br>4.5 (40)|Cu (1) 8-18<br>Cu (2) 12-18<br>Al (1) 8 Str<br>Al (1) 10 Sol|Cu (1) 10-18<br>Cu (2) 12-18|2.8 (25)<br>3.4 (30)|
||||||10-14|4.0 (35)||Al (1) 8-10|3.4 (30)|
* Covers sold separately, one cover per pole.
** Open fuse indication requires 90 volts minimum and closed circuit to operate.
Data sheet no. 10496
Eaton.com/bussmannseries
8-18
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## HM modular 250 V and 600 V Class H(K) fuse blocks
## Ratings
- Volts
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
Class H(K) modular fuse blocks enhance safety for any panel or electrical system design and are available for the full Class H(K) fuse amp range.
All blocks are available as snaptogether single-pole versions for toolless assembly of multiple poles at point of use, or as factory configured 2-, and 3-pole versions to meet stocking requirements.
All blocks are equipped with a fuse clip reinforcing spring to minimize temperature rise while maintaining reliable surface contact between the fuse and clip over the block's service life.
30 and 60 amp ferrule fuse blocks save panel space with the smallest width dimension on the market and feature DIN-Rail and panel mount versatility.
100 to 600 amp knifeblade fuse blocks feature phase barriers between poles for additional safety with up to four mounting holes per pole to increase installation flexibility. All knifeblade blocks meet UL creep and clearance requirements for Industrial Power Circuits (UL 508 and UL 845), with the 200 to 600 amp blocks meeting the higher UL creep and clearance requirements for Power Distribution Standards (UL 98, UL 67, UL 489, UL 891 and UL 869A)
All blocks are available with optional IP20 finger-safe high clarity, see-through covers for inspecting wire terminations or thermography measurements without removal. All covers enhance safety by featuring probe holes for easier, safer testing and a lockout/tagout capability. These covers also have optional open fuse indication to speed troubleshooting.
Easy circuit identification is available for 30 and 60 amp blocks and covers with universal marker labels.
- 250 V
- 600 V
- Amps up to 600
- SCCR 10 kA RMS Sym.
Agency information
- Blocks;UL Listed, Guide IZLT and IZLT7, File E14853, CSA Certified 47235-6225-01, CE
- RoHS Compliant
- Covers; UL Listed, Guide JDVS, File E58836, CSA Certified 472356225-01 (30 and 60 A)
- RoHS Compliant
## Poles
- 1-, 2-, 3-pole units factory assembled
- Single-pole units snap together to create desired number of poles
Flammability ratings
- Blocks: UL 94V0, self-extinguishing
- Covers: UL 94HB, self-extinguishing
Operating and storage temperature range
- Blocks -40°C to +120°C
- Covers; Non-Indicating -40°C to +120°C, Indicating -20°C to +90°C*
- Indication requires minimum 90 V and closed circuit to illuminate.
## Conductors
- See catalog numbers for details and torque specifications
Class K 30 and 60 amp blocks and covers
|Fuse<br>amp<br>range|Poles|Catalog no./terminal type<br>Box lug/slot<br>screw<br>Box lug/hex<br>screw|Catalog no./terminal type<br>Box lug/slot<br>screw<br>Box lug/hex<br>screw|10-32 Phil-slot<br>screw|Screw with<br>quick-connect<br>Pressure plate|Optional covers*<br>Indicating**|Non-<br>indicating|||
|---|---|---|---|---|---|---|---|---|---|
|250 volt blocks||||||||||
||1|HM25030-1CR|HM25030-1CHR|HM25030-1SR|HM25030-1QR<br>HM25030-1PR|||||
|up to 30|2|HM25030-2CR|HM25030-2CHR|HM25030-2SR|HM25030-2QR<br>HM25030-2PR|CVRI-RH-25030|CVR-RH-25030|||
||3|HM25030-3CR|HM25030-3CHR|HM25030-3SR|HM25030-3QR<br>HM25030-3PR|||||
|35 to 60<br>1<br>2<br>3<br>600 volt blocks||HM25060-1CR<br>HM25060-2CR<br>HM25060-3CR|HM25060-1CHR<br>HM25060-2CHR<br>HM25060-3CHR|—|—<br>—|CVRI-RH-25060|CVR-RH-25060|Fuse blocks and|holders|
||1|HM60030-1CR|HM60030-1CHR|HM60030-1SR|HM60030-1PR|||||
|up to 30|2|HM60030-2CR|HM60030-2CHR|HM60030-2SR|HM60030-2PR|CVRI-RH-60030|CVR-RH-60030|||
||3|HM60030-3CR|HM60030-3CHR|HM60030-3SR|—<br>HM60030-3PR|||||
||1|HM60060-1CR|HM60060-1CHR|||||||
|35 to 60|2|HM60060-2CR|HM60060-2CHR|—|—|CVRI-RH-60060|CVR-RH-60060|||
||3|HM60060-3CR|HM60060-3CHR|||||||
* Covers sold separately, one cover per pole.
** Open fuse indication requires 90 volts minimum and closed circuit to operate.
Data sheet no. 10487
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-19
**8 — Fuse blocks and holders**
Class H 100 to 600 amp knifeblade blocks and covers
|Fuse amp<br>range<br>Poles<br>Catalog no.|Fuse amp<br>range<br>Poles<br>Catalog no.|Optional covers*|Conductors***|Torque<br>N•m (lb-in)|
|---|---|---|---|---|
|||Non-indicating<br>Indicating**|Solid and stranded<br>Fine stranded||
|250 volt blocks|||||
|70-100|1<br>HM25100-1CR|CVR-RH-25100<br>CVRI-RH-25100|—<br>Cu 1-3 AWG|6.2 (55)|
||||1/0-3 AWG; (2) Cu 4-6 AWG<br>Cu 4-6 AWG|5.6 (50)|
||2<br>HM25100-2CR||2 4-6 AWG; (2) Cu 8 AWG<br>Cu 8 AWG|5.1 (45)|
||||8 AWG; (2) Cu 10-14 AWG<br>—|4.5 (40)|
||3<br>HM25100-3CR||Cu 10-14 AWG; Al 10-12 AWG<br>—|4.0 (35)|
|110-200|1<br>HM25200-1CR|CVR-RH-25200<br>CVRI-RH-25200|250kcmil-1 AWG<br>Cu 3/0-1 AWG|42 (375)|
||2<br>HM25200-2CR||2-6 AWG; (2) Cu 2-6 AWG<br>Cu 2-6 AWG|31 (275)|
||3<br>HM25200-3CR||||
|225-400|1<br>HM25400-1CR|CVR-RH-25400<br>CVRI-RH-25400|600kcmil<br>N/A<br>500kcmil-4 AWG<br>(2) Cu 3/0 - 4 AWG<br>(2) Al 3/0 - 4 AWG|57 (500)|
||2<br>HM25400-2CR|||51 (450)|
||3<br>HM25400-3CR|||57 (500)|
|||||34 (300)|
|450-600|1<br>HM25600-1CR|CVR-RH-25600<br>CVRI-RH-25600|2 (2) 500kcmil-4 AWG<br>N/A|51 (450)|
||2<br>HM25600-2CR||||
||3<br>HM25600-3CR||||
|600 volt blocks|||||
|70-100|1<br>HM60100-1CR|CVR-RH-60100<br>CVRI-RH-60100|—<br>Cu 1-3 AWG|6.2 (55)|
||||1/0-3 AWG; (2) Cu 4-6 AWG<br>Cu 4-6 AWG|5.6 (50)|
||2<br>HM60100-2CR||2 4-6 AWG; (2) Cu 8 AWG<br>Cu 8 AWG|5.1 (45)|
||||8 AWG; (2) Cu 10-14 AWG<br>—|4.5 (40)|
||3<br>HM60100-3CR||Cu 10-14 AWG; Al 10-12 AWG<br>—|4.0 (35)|
|110-200|1<br>HM60200-1CR|CVR-RH-60200<br>CVRI-RH-60200|250kcmil-1 AWG<br>Cu 3/0-1 AWG|42 (375)|
||2<br>HM60200-2CR||2-6 AWG; (2) Cu 2-6 AWG<br>Cu 2-6 AWG|31 (275)|
||3<br>HM60200-3CR||||
|225-400|1<br>HM60400-1CR|CVR-RH-60400<br>CVRI-RH-60400|600kcmil<br>N/A<br>500kcmil-4 AWG<br>(2) Cu 3/0 - 4 AWG<br>(2) Al 3/0 - 4 AWG|57 (500)|
||2<br>HM60400-2CR|||51 (450)|
||3<br>HM60400-3CR|||57 (500)|
|||||34 (300)|
|450-600|1<br>HM60600-1CR|CVR-RH-60600<br>CVRI-RH-60600|2 (2) 500kcmil-4 AWG<br>N/A|51 (450)|
||2<br>HM60600-2CR||||
||3<br>HM60600-3CR||||
- Covers sold separately.
- ** Open fuse indication requires 90 volts minimum and closed circuit to operate.
- *** Ratings for copper and aluminum conductors except where otherwise noted.
Class K 30 and 60 amp block terminals and conductors
**==> picture [263 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Torque<br>Terminal type AWG type/range AWG N•m (lb-in)<br>**----- End of picture text -----**<br>
|Terminal type<br>AWG type/range|AWG<br>Torque<br>N•m (lb-in)|
|---|---|
|Box lug<br>75°C<br>Cu 2-14,<br>AL 2-8|2-3<br>5.6 (50)|
||4-6<br>5.1 (45)|
||8<br>4.5 (40)|
||10-14<br>4.0 (35)|
|10-32 Phil-slot screw<br>75/90°C<br>Cu 10-18<br>Screw withquick-connect*<br>Pressureplate|10-18<br>2.3 (20)|
Recommended DIN-Rail stops for 30 and 60 amp blocks
|Catalogno.|Description|
|---|---|
|BRKT-ND||
|BRKT-NDSCREW2|DIN-Rail end stops|
- 3/16” quick-connect terminal maximum amps dependent on female spade connector and wire ratings.
Data sheet no. 10487
Eaton.com/bussmannseries
8-20
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## RM modular 250 V and 600 V Class R fuse blocks
Class R modular fuse blocks enhance safety for any panel or electrical system design and are available for the full Class R fuse amp range.
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
All blocks are available as snaptogether single-pole versions for toolless assembly of multiple poles at point of use, or as factory configured 2-, and 3-pole versions to meet stocking requirements.
All blocks are equipped with a fuse clip reinforcing spring to minimize temperature rise while maintaining reliable surface contact between the fuse and clip over the block's service life.
30 and 60 amp ferrule fuse blocks save panel space with the smallest width dimension on the market and feature DIN-Rail and panel mount versatility.
100 to 600 amp knifeblade fuse blocks feature phase barriers between poles for additional safety with up to four mounting holes per pole to increase installation flexibility. All knifeblade blocks meet UL creep and clearance requirements for Industrial Power Circuits (UL 508 and UL 845), with the 200 to 600 amp blocks meeting the higher UL creep and clearance requirements for Power Distribution Standards (UL 98, UL 67, UL 489, UL 891 and UL 869A).
All blocks are available with optional IP20 finger-safe high clarity, see-through covers for inspecting wire terminations or thermography measurements without removal. All covers enhance safety by featuring probe holes for easier, safer testing and a lockout/tagout capability. These covers also have optional open fuse indication to speed troubleshooting.
Easy circuit identification is available for 30 and 60 amp blocks and covers with universal marker labels.
## Ratings
- Volts
- 250 V
- 600 V
- Amps up to 600
- SCCR 200 kA RMS Sym.
## Agency information
- Blocks; UL Listed Guide IZLT and IZLT7, File E14853, CSA Certified 47235-6225-01, CE
- Covers; UL Listed Guide JDVS, File E58836, CSA Certified 472356225-01 (30 and 60 A)
- RoHS Compliant
## Poles
- 1-, 2-, 3-pole units factory assembled
- Single-pole units snap together to create desired number of poles
## Flammability ratings
- Blocks: UL 94V0, self-extinguishing
- Covers: UL 94HB, self-extinguishing
Operating and storage temperature range
- Blocks -40°C to +120°C
- Covers; Non-Indicating -40°C to +120°C, Indicating -20°C to +90°C*
- Indication requires minimum 90 V and closed circuit to illuminate.
## Conductors
- See catalog numbers for details and torque specifications
**==> picture [464 x 220] intentionally omitted <==**
**----- Start of picture text -----**<br>
Finger grips on cover Optional see-through, snap-on<br>for easy removal a cover for easy visual inspection<br>Optional open fuse indication<br>speeds troubleshooting<br>Standard phase barriers<br>for additional safety<br>Vent slots improve cooling*<br>Standard fuse clip reinforcing oud Ve<br>spring reduces temperature rise<br>Lockout/tagout feature<br>improves safety<br>Toolless interlocking modular design<br>for easy point-of-use assembly Probe holes for easy testing<br>without removing cover<br>coo DIN-rail or panel mounting on each<br>pole provides installation flexibility<br>for units rated up to 60 amps<br>**----- End of picture text -----**<br>
**==> picture [72 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
*No fuse derating necessary.<br>**----- End of picture text -----**<br>
Data sheet no. 10489
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-21
**8 — Fuse blocks and holders**
Class R 30 and 60 amp blocks and covers
**==> picture [536 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog no./terminal type Optional covers*<br>Fuse amp Box lug/ Box lug/ 10-32 screw with Non-<br>range Poles slot screw hex screw Phil-slot screw quick-connect Pressure plate Indicating** indicating<br>**----- End of picture text -----**<br>
|250 volt blocks|250 volt blocks||
|---|---|---|
|up to 30|1<br>RM25030-1CR<br>RM25030-1CHR<br>RM25030-1SR<br>RM25030-1QR|RM25030-1PR<br>CVRI-RH-25030<br>CVR-RH-25030<br>RM25030-2PR<br>RM25030-3PR|
||2<br>RM25030-2CR<br>RM25030-2CHR<br>RM25030-2SR<br>RM25030-2QR||
||3<br>RM25030-3CR<br>RM25030-3CHR<br>RM25030-3SR<br>RM25030-3QR||
|35 to 60|1<br>RM25060-1CR<br>RM25060-1CHR<br>—<br>—<br>2<br>RM25060-2CR<br>RM25060-2CHR<br>3<br>RM25060-3CR<br>RM25060-3CHR|—<br>CVRI-RH-25060<br>CVR-RH-25060|
|600 volt blocks|||
|up to 30|1<br>RM60030-1CR<br>RM60030-1CHR<br>RM60030-1SR<br>—<br>2<br>RM60030-2CR<br>RM60030-2CHR<br>RM60030-2SR<br>3<br>RM60030-3CR<br>RM60030-3CHR<br>RM60030-3SR<br>1<br>RM60060-1CR<br>RM60060-1CHR<br>—<br>2<br>RM60060-2CR<br>RM60060-2CHR<br>3<br>RM60060-3CR<br>RM60060-3CHR|RM60030-1PR<br>CVRI-RH-60030<br>CVR-RH-60030<br>RM60030-2PR<br>RM60030-3PR|
|35 to 60||—<br>CVRI-RH-60060<br>CVR-RH-60060|
* Covers sold separately, order one cover per pole.
** Open fuse indication requires 90 volts minimum and closed circuit to operate.
Class R 30 and 60 amp block terminals and conductors
**==> picture [264 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Torque<br>Terminal type AWG type/range AWG N•m (lb-in)<br>**----- End of picture text -----**<br>
|Terminal type<br>AWG type/range|AWG<br>Torque<br>N•m (lb-in)<br><br>|
|---|---|
|Box lug<br>75°C<br>Cu 2-14,<br>AL 2-8|2-3<br>5.6 (50)|
||4-6<br>5.1 (45)|
||8<br>4.5 (40)|
||10-14<br>4.0 (35)|
|10-32 Phil-slot screw<br>75/90°C<br>Cu 10-18<br>Pressureplate<br>Screw withquick-connect*|10-18<br>2.3 (20)|
- 3/16" quick-connect terminal maximum amps dependent on female spade connector and wire ratings.
Recommended DIN-Rail stops for 30 and 60 amp blocks
|Catalogno.|Description|
|---|---|
|BRKT-ND||
|BRKT-NDSCREW2|DIN-Rail end stops|
Data sheet no. 10489
Eaton.com/bussmannseries
8-22
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
Class R 100 to 600 amp knifeblade blocks and covers
|Fuse amp<br>range<br>Poles<br>Catalog no.|Fuse amp<br>range<br>Poles<br>Catalog no.|Optional covers*|Conductors***|Torque<br>N•m (lb-in)|
|---|---|---|---|---|
|||Non-indicating<br>Indicating**|Solid and stranded<br>Fine stranded||
|250 volt blocks|||||
|70-100|1<br>RM25100-1CR|CVR-RH-25100<br>CVRI-RH-25100|—<br>Cu 1-3 AWG|6.2 (55)|
||||1/0-3 AWG; (2) Cu 4-6 AWG<br>Cu 4-6 AWG|5.6 (50)|
||2<br>RM25100-2CR||2 4-6 AWG; (2) Cu 8 AWG<br>Cu 8 AWG|5.1 (45)|
||||8 AWG; (2) Cu 10-14 AWG<br>—|4.5 (40)|
||3<br>RM25100-3CR||Cu 10-14 AWG; Al 10-12 AWG<br>—|4.0 (35)|
|110-200|1<br>RM25200-1CR|CVR-RH-25200<br>CVRI-RH-25200|250kcmil-1 AWG<br>Cu 3/0-1 AWG|42 (375)|
||2<br>RM25200-2CR||2-6 AWG; (2) Cu 2-6 AWG<br>Cu 2-6 AWG|31 (275)|
||3<br>RM25200-3CR||||
|225-400|1<br>RM25400-1CR|CVR-RH-25400<br>CVRI-RH-25400|600kcmil<br>N/A<br>500kcmil-4 AWG<br>(2) Cu 3/0 - 4 AWG<br>(2) Al 3/0 - 4 AWG|57 (500)|
||2<br>RM25400-2CR|||51 (450)|
||3<br>RM25400-3CR|||57 (500)|
|||||34 (300)|
|450-600|1<br>RM25600-1CR|CVR-RH-25600<br>CVRI-RH-25600|2 (2) 500kcmil-4 AWG<br>N/A|51 (450)|
||2<br>RM25600-2CR||||
||3<br>RM25600-3CR||||
|600 volt blocks|||||
|70-100|1<br>RM60100-1CR|CVR-RH-60100<br>CVRI-RH-60100|—<br>Cu 1-3 AWG|6.2 (55)|
||||1/0-3 AWG; (2) Cu 4-6 AWG<br>Cu 4-6 AWG|5.6 (50)|
||2<br>RM60100-2CR||2 4-6 AWG; (2) Cu 8 AWG<br>Cu 8 AWG|5.1 (45)|
||||8 AWG; (2) Cu 10-14 AWG<br>—|4.5 (40)|
||3<br>RM60100-3CR||Cu 10-14 AWG; Al 10-12 AWG<br>—|4.0 (35)|
|110-200|1<br>RM60200-1CR|CVR-RH-60200<br>CVRI-RH-60200|250kcmil-1 AWG<br>Cu 3/0-1 AWG|42 (375)|
||2<br>RM60200-2CR||2-6 AWG; (2) Cu 2-6 AWG<br>Cu 2-6 AWG|31 (275)|
||3<br>RM60200-3CR||||
|225-400|1<br>RM60400-1CR|CVR-RH-60400<br>CVRI-RH-60400|600kcmil<br>N/A<br>500kcmil-4 AWG<br>(2) Cu 3/0 - 4 AWG<br>(2) Al 3/0 - 4 AWG|57 (500)|
||2<br>RM60400-2CR|||51 (450)|
||3<br>RM60400-3CR|||57 (500)|
|||||34 (300)|
|450-600|1<br>RM60600-1CR|CVR-RH-60600<br>CVRI-RH-60600|2 (2) 500kcmil-4 AWG<br>N/A|51 (450)|
||2<br>RM60600-2CR||||
||3<br>RM60600-3CR||||
* Covers sold separately, order one cover per pole.
- ** Open fuse indication requires 90 volts minimum and closed circuit to operate.
- *** Ratings for copper and aluminum conductors except where otherwise noted.
Data sheet no. 10489
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-23
**8 — Fuse blocks and holders**
## HM modular 250 V and 600 V Class H(K) power distribution fuse blocks
**==> picture [45 x 43] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>250 volt 60<br>amp modular<br>blocks.<br>**----- End of picture text -----**<br>
The patented 30 and 60 amp 250 V and 600 V Class H(K) power distribution fuse blocks use fewer wire connections to reduce watts loss and overall operating temperature of the panel, while simplifying panel layout. Available in ratings up to 400 amps, they use up to 57 percent less panel space while lowering inventory costs, and reducing installation time and labor by an average of 33 percent.
600 volt 30 and 60 amp modular blocks.
All blocks are equipped with a fuse clip reinforcing spring to minimize temperature rise while maintaining reliable surface contact between the fuse and clip over the block's service life.
Available as snap-together one-pole units for toolless assembly of multiple poles at point of use or factory configured 2- and 3-pole units to meet popular stocking requirements.
Optional see-through cover enhances safety with IP20 finger-safe protection, lockout/tagout capability and open circuit indication.
DIN-Rail and panel mount versatility allows one product to be used for multiple applications without incurring additional inventory cost.
## Ratings
- Volts
- 250 V
## Agency information
- Blocks: UL Listed, Guide IZLT, File E14853, CSA Certified 47235 - 6225-01
- Covers: UL Listed, Guide JDVS, File E58836
- RoHS compliant
## Poles
- 1-, 2-, 3-pole
- Single-pole units snap together to create desired number of poles
## Flammability ratings
- Blocks: UL 94V0, self-extinguishing
- Covers: UL 94HB, self-extinguishing
## Operating and storage temperature range
- Blocks: -40°C to +120°C
- Covers: Non-indicating -40°C to +120°C, Indicating -20°C to +90°C
## Conductors
- 75°C Cu/Al (unless otherwise noted)
## Accessories
- Optional IP20 finger-safe covers in indicating and non-indicating versions. Order one for each pole
- DIN-Rail end stops, catalog numbers BRKT-ND or BRKT-NDSCRW2
- 600 V
- Amps up to 60 A
- SCCR 10 kA RMS Sym.
**==> picture [533 x 288] intentionally omitted <==**
**----- Start of picture text -----**<br>
Available two-port Optional see-through, snap-on Finger grips on cover<br>lineside lug for easy cover for easy visual inspection for easy removal Lockout/tagout feature<br>daisy-chain wiring improves safety<br>configuration<br>Probe holes for easy testing<br>without removing cover<br>Standard phase barriers<br>for additional safety Vent slots improve cooling<br>(no fuse derating necessary)<br>oe oy ” m8<br>Optional open fuse indication<br>speeds troubleshooting<br>Toolless interlocking modular design<br>for easy point-of-use assembly<br>= — —= : eS ig a ) sit, % =<br>DIN-Rail or panel mounting on each<br>pole provides installation flexibility<br>Standard fuse clip reinforcing<br>spring reduces temperature rise<br>Multi-port loadside lug<br>Marker label provision<br>for power distribution to<br>multiple branch circuit \ for easy circuit<br>connections Ports on power distribution lugs rated for identification<br>dual-wire application, increasing the number<br>of branch circuit connections (see catalog<br>number table for details)<br>**----- End of picture text -----**<br>
Data sheet no. 10490
Eaton.com/bussmannseries
8-24
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
## **Fuse blocks and holders — 8**
|Catalog no.<br>Optional<br>covers*<br>Fuse<br>amp<br>range|Poles|Lineside (conductors per port)<br>Loadside (conductors per|Lineside (conductors per port)<br>Loadside (conductors per|port)|
|---|---|---|---|---|
|||Conductors<br>Ports/<br>pole|Torque AWG<br>N•m<br>(lb-in)<br>Conductors<br>Ports/<br>pole|Torque<br>AWG<br>N•m<br>(lb-in)|
|250 volt blocks|||||
|HM25060-1MW12<br>N/A<br>35-60<br>HM25060-2MW12<br>HM25060-3MW12<br>HM25060-1MW14<br>CVR-RH-25060<br>CVRI-RH-25060**<br>HM25060-2MW14<br>HM25060-3MW14<br>HM25060-1MW24†<br>N/A<br>HM25060-2MW24†<br>HM25060-3MW24†|1|Cu 2-14<br>Al 2-8<br>2|2-4<br>5.6 (50)<br>Cu 2-14<br>Al 2-8<br>1<br>6-10<br>4.5 (40)<br>12-14<br>1.7 (15)|2-3<br>5.6 (50)|
||2|||4-6<br>5.1 (45)|
||3|||8<br>4.5 (40)|
|||||10-14<br>4.0 (35)|
||1|Cu 2-14<br>Al 2-8<br>1|2-3<br>5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>4-6<br>5.1 (45)<br>8<br>4.5 (40)<br>10-14<br>4.0 (35)|Cu (1) 8<br>3.4 (30)|
||2|||Cu (1) 10-14<br>2.8 (25)|
||3|||Cu (2) 12-14<br>3.4 (30)|
|||||Al (1) 8-10<br>3.4 (30)|
||1|Cu 2-14<br>Al 2-8<br>2|2-4<br>5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>6-10<br>4.5 (40)<br>12-14<br>1.7 (15)|Cu (1) 8<br>3.4 (30)|
||2|||Cu (1) 10-14<br>2.8 (25)|
||3|||Cu (2) 12-14<br>3.4 (30)|
|||||Al (1) 8-10<br>3.4 (30)|
|600 volt blocks|||||
|HM60030-1MW14†<br>N/A<br>up to 30<br>HM60030-2MW14†<br>HM60030-3MW14†|1|Cu 2-14<br>Al 2-8<br>1|2-3<br>5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>4-6<br>5.1 (45)<br>8<br>4.5 (40)<br>10-14<br>4.0 (35)|Cu (1) 8<br>3.4 (30)|
||2|||Cu (1) 10-14<br>2.8 (25)|
||3|||Cu (2) 12-14<br>3.4 (30)|
|||||Al (1) 8-10<br>3.4 (30)|
|HM60060-1MW12<br>CVR-RH-60060<br>CVRI-RH-60060**<br>35-60<br>HM60060-2MW12<br>HM60060-3MW12<br>HM60060-1MW14<br>HM60060-2MW14<br>HM60060-3MW14<br>HM60060-1MW24†<br>HM60060-2MW24†<br>HM60060-3MW24†|1|Cu 2-14<br>Al 2-8<br>2|2-4<br>5.6 (50)<br>Cu 2-14<br>Al 2-8<br>1<br>6-10<br>4.5 (40)<br>12-14<br>1.7 (15)|2-3<br>5.6 (50)|
||2|||4-6<br>5.1 (45)|
||3|||8<br>4.5 (40)|
|||||10-14<br>4.0 (35)|
||1|Cu 2-14<br>Al 2-8<br>1|2-3<br>5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>4-6<br>5.1 (45)<br>8<br>4.5 (40)<br>10-14<br>4.0 (35)|Cu (1) 8<br>3.4 (30)|
||2|||Cu (1) 10-14<br>2.8 (25)|
||3|||Cu (2) 12-14<br>3.4 (30)|
|||||Al (1) 8-10<br>3.4 (30)|
||1|Cu 2-14<br>Al 2-8<br>2|2-4<br>5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>6-10<br>4.5 (40)<br>12-14<br>1.7 (15)|Cu (1) 8<br>3.4 (30)|
||2|||Cu (1) 10-14<br>2.8 (25)|
||3|||Cu (2) 12-14<br>3.4 (30)|
|||||Al (1) 8-10<br>3.4 (30)|
* Order one cover per pole.
** With open fuse indication. 90 V minimum and closed circuit required for illumination.
*** Dual wire rated lugs with same wire size and stranding.
† Rated for use with 75°C/90°C Cu/Al conductors.
Data sheet no. 10490
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-25
**8 — Fuse blocks and holders**
## RM modular 250 V and 600 V Class R power distribution fuse blocks
**==> picture [28 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
The patented 30 and 60 amp 250 V and 600 V Class R power distribution fuse blocks use fewer wire connections to reduce watts loss and overall operating temperature of the panel, while simplifying panel layout. Available in ratings up to 400 amps, they use up to 57 percent less panel space while lowering inventory costs, and reducing installation time and labor by an average of 33 percent.
High 200 kA SCCR helps achieve a higher assembly short-circuit current rating (SCCR) for compliance with NEC sections 110.10, 409.110(4), 409.22, 440.4(B), 670.3(A)(4) and 670.5.
All blocks are equipped with a fuse clip reinforcing spring to minimize temperature rise while maintaining reliable surface contact between the fuse and clip over the block's service life.
Available as snap-together one-pole units for toolless assembly of multiple poles at point of use or factory configured 2- and 3-pole units to meet popular stocking requirements.
Optional see-through cover enhances safety with IP20 finger-safe protection, lockout/tagout capability and open circuit indication.
DIN-Rail and panel mount versatility allows one product to be used for multiple applications without incurring additional inventory cost.
## Ratings
## Agency information
- Blocks; UL Listed Guide IZLT, File E14853, CSA Certified 47235 — 6225-01
- Covers; UL Listed Guide JDVS, File E58836
- RoHS compliant
## Poles
- 1-, 2-, 3-pole
- Single-pole units snap together to create desired number of poles
## Flammability ratings
- Blocks: UL 94V0, self-extinguishing
- Covers: UL 94HB, self-extinguishing
## Operating and storage temperature range
- Blocks: -40°C to +120°C
- Covers; Non-indicating -40°C to +120°C, Indicating -20°C to +90°C
## Conductors
- 75°C Cu/Al (unless otherwise noted)
## Accessories
- Optional IP20 finger-safe covers in indicating and non-indicating versions. Order one for each pole.
- DIN-Rail end stops, catalog numbers BRKT-ND or BRKT-NDSCRW2.
- Volts
- 250 V
- 600 V
- Amps up to 60 A
- SCCR 200 kA RMS Sym.
Optional see-through, snap-on Available two-port lineside cover for easy visual inspection lug for easy daisy-chain wiring configuration
Standard phase barriers for additional safety Toolless interlocking modular design for easy point-of-use assembly Standard fuse clip reinforcing spring reduces temperature rise Multi-port loadside lug for power distribution to multiple branch circuit connections Ports on power distribution lugs rated for dual-wire application, increasing the number of branch circuit connections (see catalog number table for details)
**==> picture [225 x 241] intentionally omitted <==**
**----- Start of picture text -----**<br>
Finger grips on cover<br>for easy removal<br>Lockout/tagout feature<br>t improves safety<br>mh I Probe holes for easy testing<br>without removing cover<br>in Vent slots improve cooling<br>(no fuse derating necessary)<br>Optional open fuse indication<br>i speeds troubleshooting<br>UH DIN-Rail or panel mounting on each<br>pole provides installation flexibility<br>Marker label provision<br>for easy circuit<br>identification<br>**----- End of picture text -----**<br>
Data sheet no. 10491
Eaton.com/bussmannseries
8-26
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
## **Fuse blocks and holders — 8**
|Catalog no.<br>Optional<br>covers*<br>Fuse<br>amp<br>range|Poles|Lineside (conductors per port)<br>Loadside (conductors per|Lineside (conductors per port)<br>Loadside (conductors per|port)|
|---|---|---|---|---|
|||Conductors<br>Ports/<br>pole|Torque AWG<br>N•m<br>(lb-in)<br>Conductors<br>Ports/<br>pole|Torque<br>AWG<br>N•m<br>(lb-in)|
|250 Volts|||||
|RM25060-1MW12<br>N/A<br>35 - 60<br>RM25060-2MW12<br>RM25060-3MW12<br>RM25060-1MW14<br>CVR-RH-25060<br>CVRI-RH-25060**<br>RM25060-2MW14<br>RM25060-3MW14<br>RM25060-1MW24†<br>N/A<br>RM25060-2MW24†<br>RM25060-3MW24†|1|Cu 2-14<br>Al 2-8<br>2|2-4<br>5.6 (50)<br>Cu 2-14<br>Al 2-8<br>1<br>6-10<br>4.5 (40)<br>12-14<br>1.7 (15)|2-3<br>5.6 (50)|
||2|||4-6<br>5.1 (45)|
||3|||8<br>4.5 (40)|
|||||10-14<br>4.0 (35)|
||1|Cu 2-14<br>Al 2-8<br>1|2-3<br>5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>4-6<br>5.1 (45)<br>8<br>4.5 (40)<br>10-14<br>4.0 (35)|Cu (1) 8<br>3.4 (30)|
||2|||Cu (1) 10-14<br>2.8 (25)|
||3|||Cu (2) 12-14<br>3.4 (30)|
|||||Al (1) 8-10<br>3.4 (30)|
||1|Cu 2-14<br>Al 2-8<br>2|2-4<br>5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>6-10<br>4.5 (40)<br>12-14<br>1.7 (15)|Cu (1) 8<br>3.4 (30)|
||2|||Cu (1) 10-14<br>2.8 (25)|
||3|||Cu (2) 12-14<br>3.4 (30)|
|||||Al (1) 8-10<br>3.4 (30)|
|600 Volts|||||
|RM60030-1MW14†<br>N/A<br>up to 30<br>RM60030-2MW14†<br>RM60030-3MW14†|1|Cu 2-14<br>Al 2-8<br>1|2-3<br>5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>4-6<br>5.1 (45)<br>8<br>4.5 (40)<br>10-14<br>4.0 (35)|Cu (1) 8<br>3.4 (30)|
||2|||Cu (1) 10-14<br>2.8 (25)|
||3|||Cu (2) 12-14<br>3.4 (30)|
|||||Al (1) 8-10<br>3.4 (30)|
|RM60060-1MW12<br>CVR-RH-60060<br>CVRI-RH-60060**<br>35-60<br>RM60060-2MW12<br>RM60060-3MW12<br>RM60060-1MW14<br>RM60060-2MW14<br>RM60060-3MW14<br>RM60060-1MW24†<br>RM60060-2MW24†<br>RM60060-3MW24†|1|Cu 2-14<br>Al 2-8<br>2|2-4<br>5.6 (50)<br>Cu 2-14<br>Al 2-8<br>1<br>6-10<br>4.5 (40)<br>12-14<br>1.7 (15)|2-3<br>5.6 (50)|
||2|||4-6<br>5.1 (45)|
||3|||8<br>4.5 (40)|
|||||10-14<br>4.0 (35)|
||1|Cu 2-14<br>Al 2-8<br>1|2-3<br>5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>4-6<br>5.1 (45)<br>8<br>4.5 (40)<br>10-14<br>4.0 (35)|Cu (1) 8<br>3.4 (30)|
||2|||Cu (1) 10-14<br>2.8 (25)|
||3|||Cu (2) 12-14<br>3.4 (30)|
|||||Al (1) 8-10<br>3.4 (30)|
||1|Cu 2-14<br>Al 2-8<br>2|2-4<br>5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>6-10<br>4.5 (40)<br>12-14<br>1.7 (15)|Cu (1) 8<br>3.4 (30)|
||2|||Cu (1) 10-14<br>2.8 (25)|
||3|||Cu (2) 12-14<br>3.4 (30)|
|||||Al (1) 8-10<br>3.4 (30)|
* Order one cover per pole.
** With open fuse indication. 90 V minimum and closed circuit required for illumination.
- *** Dual wire rated lugs with same wire size and stranding.
† Rated for use with 75°C/90°C Cu/Al conductors.
Data sheet no. 10491
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-27
**8 — Fuse blocks and holders**
## CH _ _ J _ Class J fuse holder
## Features
- Choice of local fuse indication; easyID™ viewing window (for seeing indicator on LPJ-SPI indicating fuse) or neon lamp
The CH_J_ Class J fuse holders are available in 30 and 60 amp ratings featuring IP20 finger-safe construction that can be either DIN-Rail or panel mounted. Available as factory configured 1-, 2- or 3-pole holders they are available with optional open fuse indication to speed troubleshooting.
- Versatile 1-, 2- and 3-pole versions for 0-30 A and 35-60 A fuses with dual wire rated connections simplify wiring
- Improved electrical safety with IP20 finger-safe construction with lock-out/tag-out feature. 3-phase fuse extraction assures all phases are opened for service work
> • Flexible panel/35mm DIN-Rail mounting
|rw!|rw!<br>f|Improved electrical safety with IP20 finger-safe construction with<br>lock-out/tag-out feature. 3-phase fuse extraction assures all phases<br>are opened for service work<br>• Flexible panel/35mm DIN-Rail mounting|Improved electrical safety with IP20 finger-safe construction with<br>lock-out/tag-out feature. 3-phase fuse extraction assures all phases<br>are opened for service work<br>• Flexible panel/35mm DIN-Rail mounting|Improved electrical safety with IP20 finger-safe construction with<br>lock-out/tag-out feature. 3-phase fuse extraction assures all phases<br>are opened for service work<br>• Flexible panel/35mm DIN-Rail mounting|Improved electrical safety with IP20 finger-safe construction with<br>lock-out/tag-out feature. 3-phase fuse extraction assures all phases<br>are opened for service work<br>• Flexible panel/35mm DIN-Rail mounting|Improved electrical safety with IP20 finger-safe construction with<br>lock-out/tag-out feature. 3-phase fuse extraction assures all phases<br>are opened for service work<br>• Flexible panel/35mm DIN-Rail mounting|
|---|---|---|---|---|---|---|
|60 A<br>— <br>do|f<br>|Dimensions — mm<br>Fuse amps<br>Poles<br>W<br>D<br>H<br>Up to 30 A<br>1<br>32<br>70<br>115<br>2<br>64<br>3<br>96<br>1<br>40<br> ~~$$.~~<br>~~OO~~|||||
||||35-60 A|2<br>80|83|125|
|||||3<br>120|||
## Ratings
|•|Volts 600 V (or less)|easyID|—|
|---|---|---|---|
|•|Amps|Jel|do|
||• 30 A|||
||• 60 A|30 A|60 A|
|•|SCCR 200 kA|||
## Agency information
- UL Listed, Guide IZLT, File E14853, UL 4248/CSA 22.2 No. 4248.P, CE
## Conductors
- Single 1-18 AWG and dual 3-18 AWG Cu solid and stranded conductors
## Terminal torque ratings
- 10-18 AWG 24 lb-in
- 1-8 AWG 35 lb-in
Storage and operating temperature range*
- -20°C to +75°C
- For fuse selection on applications above or below 25ºC, consult derating charts in the Bussmann Division publication no. 3002 “Selecting Protective Devices” (SPD).
Flammability rating UL 94V0
|Catalog no.|Catalog no.||||||||
|---|---|---|---|---|---|---|---|---|
|Without indication*|Without indication*<br>With indication**|Poles|Amps|Volts<br>(AC/DC)|IP20<br>finger-<br>safe|AWG Cu wire range|Padlockable|Mounting|
|CH30J1|CH30J1I|1|||||||
|CH30J2|CH30J2I|2|30|600|Yes|Single 1-18, dual 3-18|Yes|35mm DIN/ panel|
|CH30J3|CH30J3I|3|||||||
|CH60J1|CH60J1I|1|||||||
|CH60J2|CH60J2I|2|60|600|Yes|Single 1-18, dual 3-18|Yes|35mm DIN/ panel|
|CH60J3|CH60J3I|3|||||||
* Local fuse indication 6 amps and above possible using Bussmann series LPJ_SPI permanent indication fuses.
** Neon indication non-fuse dependent, minimum voltage 90 V.
Data sheet no. 2144
Eaton.com/bussmannseries
8-28
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## JT(N)60030 and JT(N)60060 Safety J™ modular finger-safe Class J fuse holders
## Typical applications
> • Industrial controls
The Bussmann series Safety J™ • Process controls modular fuse holders are available • Small horsepower VFDs in indicating and non-indicating versions. Finger-safe construction Dimensions — in (mm) improves electrical safety, while modular construction permits dovetailing the required number of poles* at point of use. DIN-Rail mount provides for easy installation. (29.0)1.141.14 (26.7)1.051.05 Optional open fuse indication ia 30 A version 60 A version Q Tie | == Fe speeds troubleshooting.
**==> picture [263 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
(29.0)1.141.14 (26.7)1.051.05<br>Slot Din-rail<br>[nel 0.07 ———<br>MOUNTING (1.8) 1.23<br>Shown without fuse pullout cover (31.2) 2.42<br>(61.3)<br>3.60<br>2.75 = (91.4) a<br>(69.9)<br>2.52<br>(64.1)<br>**----- End of picture text -----**<br>
- JT(N)60030 cannot be dovetailed to JT(N)60060.
## Ratings
- Volts 600 Vac
- Amps
- Up to 30 A (JT(N)60030)
- 35--60 A (JT(N)60060)
- SCCR
- 200 kA RMS Sym.
- 300 kA self certified using Bussmann series LPJ_SP fuses
## Agency information
- Listed to UL 4248: Guide IZLT, File 14853, CSA Certified: Class 6225-01, File 47235. IP20 per IEC 60529, CE JT(N)60030
Catalog numbers and conductor information
Catalog no. Terminal Holder Non75°C Cu conductor torque 1.31 1.25 amps indicating Indicating* size (AWG) and type N•m (lb-in) (33.3) (31.8) 8-18 stranded, single or dual** 30 JT60030 JTN60030 2.26 (20) Slot Din-rail 10-18 solid, single or dual** 4-14 stranded or solid, 60 JT60060 JTN60060 single 5.1 (45) 0.10 ~~mee~~ 8-10 stranded, dual** (2.6) (38.1)1.52 **MOUNTING** 2.96 * Indication non-fuse dependent, minimum 90 V. Shown without fuse pullout cover (75.2) 4.40 ~~Be|~~ ** Dual wire applications must use conductors of the same size and type. 3.10 iJ (111.7) (78.7) Dimensions — in (mm) JT60030, JTN60030 Flammability rating: UL 94V0 3.06 (77.7)
## Open fuse indication
Min. voltage: 90 V; neon lamp “ON” when fuse opens, voltage source and current path are present.
JT(N)60060
## Features
**==> picture [13 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
holders<br>Fuse blocks and<br>**----- End of picture text -----**<br>
- 300 kA SCCR with Bussmann series LPJ_SP fuses
- Rapid, flexible 35mm DIN-Rail mounting
- One piece interlocking design for assembling multiple pole blocks reduces inventory costs
- Removable fuse carrier allows fuse replacement away from base while maintaining finger-safe rating
Data sheet no. 1152
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-29
**8 — Fuse blocks and holders**
## JP pyramid style 3-pole Class J fuse block
The Bussmann series JP (pyramid) open fuse block provides a means of mounting a three-pole 30 amp Class J fuse block with a footprint that is narrower than traditional solutions. See catalog numbers for terminals and conductor information.
## Ratings
Volts 600 V Amps 30 A SCCR 200 kA RMS Sym.
Agency information
- UL Listed, UL 4248, Guide IZLT, File E14853, CSA Certified, C22.2 No. 39, Class 4225-04, File 47235, CE
## Flammability rating UL 94V0
## Mounting
- Panel
- 35mm DIN-Rail*
* To order DIN-Rail, specify catalog number DRL35MMLO (1 meter).
||Mounting|Mounting|Terminals/AWG wire range/<br>type|Terminals/AWG wire range/|
|---|---|---|---|---|
|Catalogno.|Panel|DIN-Rail*|Pressureplate|Box lug|
|JP60030-3PR|Yes|No|10-14 Cu|—|
|JP60030-3CR|Yes|No|—|2-14 Cu/Al|
|JP60030-3COR|Yes|No|—|2-14 Cu|
|JP60030-3PRA|No|Yes|10-14 Cu|—|
|JP60030-3CRA|No|Yes|—|2-14 Cu/Al|
|JP60030-3CORA|No|Yes|—|2-14 Cu|
* Requires adapter, order catalog number JPA-3.
## Dimensions — in
**==> picture [156 x 223] intentionally omitted <==**
**----- Start of picture text -----**<br>
DIN-Rail mounting screw 8 inches (203mm) apart<br>End stops prevent block movement when changing fuses<br>4.0 max.<br>(101)<br>3.75<br>(95)<br>1.88<br>(48)<br>1.19 (30)<br>2.38 (60)<br>3.29 (84)<br>2.78<br>3.06 (71)<br>(78)<br>3.13<br>_—— (80)<br>JPA-3 adaptor for symmetrical mounting on a 35mm DIN-Rail<br>**----- End of picture text -----**<br>
Data sheet no. 1108
Eaton.com/bussmannseries
8-30
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## JM modular Class J fuse blocks
## Ratings
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
Class J modular fuse blocks enhance safety for any panel or electrical system design and are available for the full Class J fuse amp range.
All blocks are available as single-pole versions that snap together at point of use, or as factory configured 2-, and 3-pole versions.
**==> picture [107 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
30 and 60 amp blocks are DIN-Rail and<br>panel mount. Optional covers increase<br>safety.<br>**----- End of picture text -----**<br>
All blocks are equipped with a fuse clip reinforcing spring to minimize temperature rise while maintaining reliable surface contact between the fuse and clip over the block's service life.
**==> picture [112 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
100 to 600 amp blocks are panel mount.<br>Optional covers increase safety.<br>**----- End of picture text -----**<br>
Ferrule fuse blocks up to 60 amps have the smallest width dimension on the market and feature DIN-Rail or panel mount versatility. Easy circuit identification is available for 30 and 60 amp blocks and covers with universal marker labels.
Knifeblade fuse blocks from 100 to 600 amps feature phase barriers for additional safety with up to four mounting holes per pole for increased installation flexibility. All knifeblade blocks meet UL creep and clearance requirements for Industrial Power Circuits (UL 508 and UL 845). The 200 to 600 amp blocks also meet the higher UL creep and clearance requirements for Power Distribution Standards (UL 98, UL 67, UL 489, UL 891 and UL 869A)
All blocks have optional IP20 finger-safe high clarity, see-through covers for inspecting wire terminations or thermography measurements without removal. All covers enhance safety by featuring probe holes for easier, safer testing and a lockout/tagout capability. These covers also have optional open fuse indication to speed troubleshooting.
**==> picture [93 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
Optional see-through, snap-on<br>cover for easy visual inspection<br>**----- End of picture text -----**<br>
**==> picture [156 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
Standard phase barriers<br>for additional safety<br>Toolless interlocking modular design<br>for easy point-of-use assembly<br>~<br>DIN-Rail or panel mounting on each<br>pole provides installation flexibility<br>(DIN-Rail mounting applies to 30<br>and 60 A blocks only)<br>Standard fuse clip reinforcing<br>spring reduces temperature rise<br>**----- End of picture text -----**<br>
- Volts 600 V
- Amps up to 600 A
- SCCR 200 kA RMS Sym.
## Agency information
- Blocks; UL Listed E14853 — IZLT and IZLT7, CSA Certified 472356225-01, CE, RoHS Compliant
- Covers; UL Listed E58836 - JDVS, CSA Certified 47235-6225-01 (30 and 60 A), RoHS Compliant
## Poles
- 1-, 2-, 3-pole units factory assembled
- Single-pole units snap together to create desired number of poles
## Flammability ratings
- Blocks: UL 94V0, self-extinguishing
- Covers: UL 94HB, self-extinguishing
Operating and storage temperature range
- Blocks -40°C to +120°C
- Covers; non-indicating -40°C to +120°C, indicating -20°C to +90°C*
- Indication requires minimum 90 V and closed circuit to illuminate.
## Conductors
- See catalog numbers for details and torque specifications.
**==> picture [248 x 207] intentionally omitted <==**
**----- Start of picture text -----**<br>
Finger grips on cover<br>Marker label provision<br>for easy removal<br>for easy circuit<br>identification (applies to<br>30 and 60 A blocks only)<br>Vent slots improve cooling<br>\) AQ (no fuse derating necessary)<br>WL S<br>Optional open fuse indication<br>speeds troubleshooting<br>Lockout/tagout feature<br>x SS improves safety<br>Probe holes for easy testing<br>without removing cover<br>**----- End of picture text -----**<br>
Data sheet no. 10488
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-31
**8 — Fuse blocks and holders**
30 and 60 amp blocks and covers
**==> picture [538 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse amp Catalog no./terminal type Optional covers*<br>range Poles Box lug/slot screw Box lug/hex screw 10-32 Phil-slot screw Pressure plate Indicating** Non-indicating<br>**----- End of picture text -----**<br>
|up to 30|1<br>JM60030-1CR<br>JM60030-1CHR<br>JM60030-1SR<br>JM60030-1PR<br>CVRI-J-60030<br>CVR-J-60030<br>2<br>JM60030-2CR<br>JM60030-2CHR<br>JM60030-2SR<br>JM60030-2PR<br>3<br>JM60030-3CR<br>JM60030-3CHR<br>JM60030-3SR<br>JM60030-3PR|
|---|---|
|35 to 60|1<br>JM60060-1CR<br>JM60060-1CHR<br>—<br>—<br>CVRI-J-60060<br>CVR-J-60060<br>2<br>JM60060-2CR<br>JM60060-2CHR<br>3<br>JM60060-3CR<br>JM60060-3CHR|
* Covers sold separately, one cover per pole.
** Open fuse indication requires 90 volts minimum and closed circuit to operate.
## 30 and 60 amp block terminals and conductors
**==> picture [264 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal type AWG type/range AWG Torque N•m (lb-in)<br>**----- End of picture text -----**<br>
|Terminal type<br>AWG type/range|AWG<br>Torque N•m (lb-in)<br>|
|---|---|
|Box lug<br>75°C<br>Cu 2-14,<br>Al 2-8|2-3<br>5.6 (50)|
||4-6<br>5.1 (45)|
||8<br>4.5 (40)|
||10-14<br>4.0 (35)|
|10-32 Phil-slot<br>screw<br>75/90°C<br>Cu 10-18<br>Pressureplate|10-18<br>2.3 (20)|
## 100 to 600 amp knifeblade blocks and covers
**==> picture [538 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
Optional covers* Conductors***<br>Fuse amp Torque<br>range Poles Catalog no. Non-indicating Indicating** Solid and stranded Fine stranded N•m (lb-in)<br>**----- End of picture text -----**<br>
|70-100|1<br>JM60100-1CR<br>CVR-J-60100-M<br>CVRI-J-60100-M<br>2<br>JM60100-2CR<br>3<br>JM60100-3CR|—<br>Cu 1-3 AWG|6.2 (55)|
|---|---|---|---|
|||1/0-3 AWG; (2) Cu 4-6 AWG<br>Cu 4-6 AWG|5.6 (50)|
|||2 4-6 AWG; (2) Cu 8 AWG<br>Cu 8 AWG|5.1 (45)|
|||8 AWG; (2) Cu 10-14 AWG<br>—|4.5 (40)|
|||Cu 10-14 AWG; Al 10-12 AWG<br>—|4.0 (35)|
|110-200|1<br>JM60200-1CR<br>CVR-J-60200-M<br>CVRI-J-60200-M<br>2<br>JM60200-2CR<br>3<br>JM60200-3CR|250kcmil-1 AWG<br>Cu 3/0-1 AWG|42 (375)|
|||2-6 AWG; (2) Cu 2-6 AWG<br>Cu 2-6 AWG|31 (275)|
|225-400|1<br>JM60400-1CR<br>CVR-J-60400-M<br>CVRI-J-60400-M<br>2<br>JM60400-2CR<br>3<br>JM60400-3CR<br>1<br>JM60400-1MW22<br>2<br>JM60400-2MW22<br>3<br>JM60400-3MW22|600kcmil<br>N/A<br>500kcmil-4 AWG<br>(2) Cu 3/0 - 4 AWG<br>(2) Al 3/0 - 4 AWG|57 (500)|
||||51 (450)|
||||57 (500)|
||||34 (300)|
|450-600|1<br>JM60600-1CR<br>CVR-J-60600<br>CVRI-J-60600<br>2<br>JM60600-2CR<br>3<br>JM60600-3CR|2 (2) 500kcmil-4 AWG<br>N/A|51 (450)|
- Covers sold separately.
- ** Open fuse indication requires 90 volts minimum and closed circuit to operate.
- *** Ratings for copper and aluminum conductors except where otherwise noted.
Data sheet no. 10488
Eaton.com/bussmannseries
8-32
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## JM modular Class J power distribution fuse blocks
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
The patented Class J power distribution fuse blocks use fewer wire connections to reduce watts loss and overall operating temperature of the panel, while simplifying panel layout. Available in ratings up to 400 amps, they use up to 65 percent less panel space while lowering inventory costs, and reducing installation time and labor by an average of 33 percent.
**==> picture [66 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
30 and 60 amp blocks.<br>**----- End of picture text -----**<br>
All blocks are equipped with a fuse clip reinforcing spring to minimize temperature rise while maintaining reliable surface contact between the fuse and clip over the block's service life.
100, 200 and 400 amp blocks.
Available as snap-together one-pole units for toolless assembly of multiple poles at point of use or factory configured 2- and 3-pole units to meet popular stocking requirements.
The high 200 kA SCCR helps achieve a higher assembly short-circuit current rating (SCCR) for compliance with NEC sections 110.10, 409.110(4), 409.22, 440.4(B), 670.3(A)(4) and 670.5.
30 and 60 amp blocks feature DIN-Rail and panel mount versatility, while 100 to 400 amp blocks are panel mount.
All blocks are available with optional see-through cover to enhance safety with IP20 finger-safe protection, lockout/tagout capability and open circuit indication. See catalog number tables for details.
## Ratings
- Volts 600 V
## Agency information
- Blocks; UL Listed, Guide IZLT, File E14853, CSA Certified 47235 — 6225-01
- Covers; UL Listed, Guide JDVS, File E58836
- RoHS compliant
## Poles
- 1-, 2-, 3-pole
- Single-pole units snap together to create desired number of poles
## Mounting
- 30 and 60 amp blocks DIN-Rail and panel mount
- 100, 200 and 400 amp blocks panel mount only
## Flammability ratings
- Blocks, UL 94V0, self-extinguishing
- Covers; UL 94HB, self-extinguishing
## Operating and storage temperature range
- Blocks, -40°C to +120°C
- Covers; non-indicating -40°C to +120°C, indicating -20°C to +90°C
## Conductors
- 75/90°C Cu/Al (unless otherwise noted)
## Accessories
- IP20 finger-safe covers in indicating and non-indicating versions. Order one for each pole.
- DIN-Rail end stops for blocks rated up to 60 amps, catalog numbers BRKT-ND or BRKT-NDSCRW2
- Amps up to 400 A
- SCCR 200 kA Sym. RMS
Available two-port lineside lug for easy daisy-chain wiring configuration. See catalog number table for applicable catalog numbers.
Standard phase barriers for additional safety
Optional see-through, snap-on cover for easy visual inspection
**==> picture [219 x 40] intentionally omitted <==**
**----- Start of picture text -----**<br>
Finger grips on cover Lockout/tagout feature<br>for easy removal improves safety<br>Probe holes for easy testing<br>without removing cover<br>**----- End of picture text -----**<br>
Vent slots improve cooling (no fuse derating necessary) Optional open fuse indication speeds troubleshooting
Toolless interlocking modular design for easy point-of-use assembly
DIN-Rail or panel mounting on each pole provides installation flexibility (DIN-Rail mounting applies to 30 and 60 A blocks only)
Standard fuse clip reinforcing spring reduces temperature rise
Multi-port loadside lug for power distribution to Ports on power distribution lugs rated multiple branch circuit connections for dual-wire application, increasing the number of branch circuit connections (see catalog number table for details)
Marker label provision for easy circuit identification (applies to 30 and 60 A blocks only)
Data sheet no. 10192
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-33
## **8 — Fuse blocks and holders**
**==> picture [537 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse Lineside (conductors per port) Loadside (conductors per port)<br>Optional amp Ports/ N•m Ports/ Torque N•m<br>Catalog no. covers* range Poles Conductors pole Torque AWG (lb-in) Conductors pole AWG (lb-in)<br>**----- End of picture text -----**<br>
|JM60030-1MW14<br>N/A<br>Up to 30<br>JM60030-2MW14<br>JM60030-3MW14|1<br>Cu 2-14<br>Al 2-8<br>1<br>2<br>3|2-3|5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>5.1 (45)<br>4.5 (40)<br>4.0 (35)|Cu (1) 8<br>3.4 (30)|
|---|---|---|---|---|
|||4-6||Cu (1) 10-14<br>2.8 (25)|
|||8||Cu (2) 12-14<br>3.4 (30)|
|||10-14||Al (1) 8-10<br>3.4 (30)|
|JM60060-1MW12†<br>CVR-J-60060<br>CVRI-J-60060**<br>35 - 60<br>JM60060-2MW12†<br>JM60060-3MW12†<br>JM60060-1MW14†<br>JM60060-2MW14†<br>JM60060-3MW14†<br>JM60060-1MW24<br>JM60060-2MW24<br>JM60060-3MW24|1<br>Cu 2-14<br>Al 2-8<br>2<br>2<br>3|2-4|5.6 (50)<br>Cu 2-14<br>Al 2-8<br>1<br>4.5 (40)<br>1.7 (15)|2-3<br>5.6 (50)|
|||6-10||4-6<br>5.1 (45)|
|||12-14||8<br>4.5 (40)|
|||||10-14<br>4.0 (35)|
||1<br>Cu 2-14<br>Al 2-8<br>1<br>2<br>3|2-3|5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>5.1 (45)<br>4.5 (40)<br>4.0 (35)|Cu (1) 8<br>3.4 (30)|
|||4-6||Cu (1) 10-14<br>2.8 (25)|
|||8||Cu (2) 12-14<br>3.4 (30)|
|||10-14||Al (1) 8-10<br>3.4 (30)|
||1<br>Cu 2-14<br>Al 2-8<br>2<br>2<br>3|2-4|5.6 (50)<br>Cu (1) 8-14<br>Cu (2) 12-14***<br>Al (1) 8 Str<br>Al (1) 10 Sol<br>4<br>4.5 (40)<br>1.7 (15)|Cu (1) 8<br>3.4 (30)|
|||6-10||Cu (1) 10-14<br>2.8 (25)|
|||12-14||Cu (2) 12-14<br>3.4 (30)|
|||||Al (1) 8-10<br>3.4 (30)|
|JM60100-1MW14<br>CVR-J-60100-M<br>CVRI-J-60100-M**<br>70 - 100<br>JM60100-2MW14<br>JM60100-3MW14|1<br>Cu 1/0-14<br>Al 1/0-12<br>1<br>2<br>3|1/0-3; Cu (2) 4-6|5.6 (50)<br>Cu (1) 4-14<br>Al (1) 4-8<br>Cu (2) 10-14***<br>4<br>5.0 (45)<br>4.5 (40)<br>4.0 (35)|4-6<br>4.0 (35)|
|||4-6; Cu (2) 8||8<br>2.8 (25)|
|||8; Cu (2) 10-14||Cu 10-14<br>2.3 (20)|
|||10-14||(2) 10-14<br>3.4 (30)|
|JM60200-1MW16<br>CVR-J-60200-M<br>CVRI-J-60200-M**<br>110-200<br>JM60200-2MW16<br>JM60200-3MW16|1<br>Cu/Al (1) 250kcmil-6<br>Cu (2) 2-6<br>1<br>2<br>3|250kcmil-1|42 (375)<br>Cu (1) 4-14<br>Al (1) 4-8<br>Cu (2) 10-14***<br>6<br>31 (275)|4-6<br>4.0 (35)|
|||||8<br>2.8 (25)|
|||2-6||10-14<br>2.3 (20)|
|||||(2) 10-14<br>3.4 (30)|
|JM60400-1MW16<br>CVR-J-60400-M<br>CVRI-J-60400-M**<br>225-400<br>JM60400-2MW16<br>JM60400-3MW16<br>JM60400-1MW26<br>JM60400-2MW26<br>JM60400-3MW26|1<br>Cu/Al (1) 600kcmil-4<br>Cu/Al (2) 3/0-4<br>1<br>2<br>3|600kcmil|57 (500)<br>Cu (1) 2-14<br>Al (1) 2-8<br>Cu (2) 8-14***<br>6<br>51 (450)<br>57 (500)<br>34 (300)|2-3<br>5.6 (50)|
|||500kcmil-4||4-6<br>5.0(45)|
|||||8<br>4.5(40)|
|||||(2)8<br>4.5(40)|
|||Cu (2) 3/0-4<br>Al (2) (3/0-4||10-14<br>4.0 (35)|
|||||(2) 10-14<br>4.5 (40)|
||1<br>Cu/Al 350kcmil-6<br>2<br>2<br>3|350kcmil-1|42 (375)<br>Cu (1) 2-14<br>Al (1) 2-8<br>Cu (2) 8-14***<br>6<br>31 (275)|2-3<br>5.6(50)|
|||||4-6<br>5.0(45)|
|||||8<br>4.5(40)|
|||||(2) 8<br>4.5 (40)|
|||2-6||10-14<br>4.0 (35)|
|||||(2) 10-14<br>4.5 (40)|
- Order one cover per pole.
- ** With open fuse indication. 90 V minimum and closed circuit required for illumination.
- *** Dual wire rated lugs with same wire size and stranding.
- Rated for 75°C Cu/Al conductors. Conductors with higher ratings may be used with appropriate derating.
Data sheet no. 10192
Eaton.com/bussmannseries
8-34
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## T300 300 volt Class T fuse blocks
## Dimensions — in
**==> picture [261 x 455] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.63 A 1.63<br>0.72 1.20 B 0.72<br>0.16 | 0.69 X Z - 0.16<br>0.91 2.75 2.5 0.91<br>T30030-S X Z T30060-C<br>SECTION X-X 0.44 Full SECTION Z-Z<br>0.20 Radius<br>C<br>Figure 1. Up to 60 A<br>Dimensions — in<br>Catalog no. A B C<br>T30030-2 2.41 — 1.03<br>T30060-2 2.41 — 1.03<br>T30030-3 3.44 1.03 2.06<br>T30060-3 3.44 1.03 2.06<br>T30030-4 4.47 2.06 3.09<br>T30060-4 4.47 2.06 3.09<br>1.69 (1 POLE)<br>3.09 (2 POLE)<br>4.5 (3 POLE)<br>2.06<br>0.84 1.41 (2 POLE)<br>2.81 (3 POLE)<br>nr<br>L |<br>X Z<br>TH GB<br>0.22 DIA<br>0.52 C'BORE<br>0.55 DEEP<br>2.25<br>4.78<br>REF<br>2.39<br>X Z<br>0.38<br>0.75<br>**----- End of picture text -----**<br>
Bussmann series T300 fuse blocks are open fuse blocks for use with Class T fuses up to 600 amps in various pole configurations from 1- to 4-poles. T300 blocks use Bussmann series JJN fuses.
Ratings
- Volts 300 V
- Amps up to 600 A
Figure 1. Up to 60 A
- SCCR 200 kA RMS Sym.
## Agency information
- UL Listed UL 4248, Guide IZLT, File E14853, CSA Certified, Class 6225-01, File 47235, CE
Flammability rating UL 94V0
## Features
- Provide 1-, 2-, 3- and 4-pole housing for 300 Vac Class T fuses
- High 200 kA RMS Sym. Short-Circuit Current Rating
- Class T fuse blocks have a small foot print, providing substantial space savings in equipment
Typical applications
- 300 V or less control systems
- 300 V or less individual control circuits
## Catalog numbers
**==> picture [507 x 264] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Catalog no./terminals|Terminal AWG wire|
|2.25|
|Screw|Box lug|Amps|Poles|Fig.|range/type|4.78|REF|
|T30030-2SR|T30030-2CR|2|
|SR 10-18 Cu|
|T30030-3SR|T30030-3CR|Up to 30|3|CR 6-14 Cu/Al|2.39|
|T30030-4SR|T30030-4CR|4|
|1|
|T30060-2SR|T30060-2CR|2|
|CR 2-14 Cu/Al|
|T30060-3SR|T30060-3CR|31-60|3|SR 10-18 Cu|X|Z|
|T30060-4SR|T30060-4CR|4|0.38|
|—|T30100-1CR|1|0.75|
|—|T30100-2CR|61-100|2|2|1/0-8 Cu/Al|Figure 2. 61 to 100 A|
|—|T30100-3CR|3|
|eT|——|T30200-1CT30200-3C|101-200|13|34|250kcmil-6 Cu/Al|——|3|6|0.05|
|—|T30400-1C|201-400|1|5|600kcmil-2/0 Cu/Al|1.125|
|OO|—|T30600-1C|401-600|1|6|(2) 600kcmil-4/0 Cu/Al|[==|1.25|T|2.25|
|oo|HOO|OO)|||
|1.69|0.28 DIAMETER|
|0.63 C'BORE 0.5 DEEP|
|3.06|
|2.56|
|1.94|i|t|el|
|0.81|
|Lt|T|=|
**----- End of picture text -----**<br>
Figure 3. 101 to 200 A
Data sheet no. 1115
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-35
## **8 — Fuse blocks and holders**
**==> picture [230 x 189] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.87<br>1.695<br>0.996<br>A 2.75<br>A<br>0.282 DIAMETER THRU HOLE, 0.625 C'BORE 0.438 DEEP<br>2.375<br>0.625<br> 4.46<br>**----- End of picture text -----**<br>
Figure 4. 200 A
**==> picture [240 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
6<br>3<br>1.25 2.25<br>1.125<br>0.63<br>0.28 DIAMETER, 0.63 C'BORE 0.5" DEEP<br>1.84<br>3.06<br>2.38<br>0.81<br>**----- End of picture text -----**<br>
Figure 5. 201 to 400 A
**==> picture [260 x 217] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.75<br>2.88<br>1.5<br>2 3<br>0.33 DIAMETER<br>0.75 C'BORE 0.5 DEEP<br>2.03<br>3.44<br>3<br>0.75<br>**----- End of picture text -----**<br>
Figure 6. 401 to 600 A
Data sheet no. 1115
Eaton.com/bussmannseries
8-36
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8** ~~a~~
T600 600 volt Class T fuse blocks
Bussmann series T600 fuse blocks are open fuse blocks for use with Class T fuses up to 600 amps in various pole configurations from 1- to 3-poles. T600 blocks use Bussmann series JJS fuses.
## Ratings
- Volts 600 V
- Amps up to 600 A
- SCCR 200 kA RMS Sym.
## Agency information
- UL Listed, UL 4248, Guide IZLT, File E14853, CSA Certified, Class 6225-01, File 47235, CE
Flammability rating UL 94V0
Features
Typical applications • 600 V or less control systems • 600 V or less individual control circuits
|Catalogno./terminals<br>Amps<br>Poles<br>Fig.<br>Terminal AWG<br>range/type<br>Screw<br>Box lug<br>~~ee~~|Catalogno./terminals<br>Amps<br>Poles<br>Fig.<br>Terminal AWG<br>range/type<br>Screw<br>Box lug<br>~~ee~~|Catalogno./terminals<br>Amps<br>Poles<br>Fig.<br>Terminal AWG<br>range/type<br>Screw<br>Box lug<br>~~ee~~|Catalogno./terminals<br>Amps<br>Poles<br>Fig.<br>Terminal AWG<br>range/type<br>Screw<br>Box lug<br>~~ee~~|Catalogno./terminals<br>Amps<br>Poles<br>Fig.<br>Terminal AWG<br>range/type<br>Screw<br>Box lug<br>~~ee~~|Catalogno./terminals<br>Amps<br>Poles<br>Fig.<br>Terminal AWG<br>range/type<br>Screw<br>Box lug<br>~~ee~~|
|---|---|---|---|---|---|
|T60030-1SR|T60030-1CR||1|||
|T60030-2SR|T60030-2CR|Up to<br>30|2|1|SR 10-18 Cu<br>CR 2-14 Cu/Al|
|T60030-3SR|T60030-3CR||3|||
|T60060-1SR|T60060-1CR||1|||
|T60060-2SR|T60060-2CR|31-60|2|2|SR 10-18 Cu<br>CR 2-14 Cu/Al|
|T60060-3SR|T60060-3CR||3|||
|—|T60100-1C||1|||
|—|T60100-2C|61-100|2|3|2/0-14 Cu/Al|
|—|T60100-3C||3|||
|—|T60200-1C||1|4||
|—|1B0089*|101-200|3|5|250kcmil-6 Cu/Al|
|—|T60400-1C|201-400|1|6|600kcmil-2/0 Cu/Al|
|—|T60600-1C|401-600|1|7|(2) 600kcmil-4/0 Cu/Al|
- UL Listed, Guide IZLT, File E14853, CSA Certified Class 6225-01, File 21455M18.
- Provide 1-, 2- and 3-pole housing for 600 Vac Class T fuses.
- High 200 kA RMS Sym. Short-Circuit Current Ratings
- Class T fuse blocks have a small foot print, providing substantial space savings in equipment
Dimensions — in
**==> picture [491 x 263] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.44 1.44 2.59 3.75<br>0.5 0.55 0.33 0.55 1.16 0.33 0.55 2.31 0.33<br>0.22 DIAMETER,<br>a a Tan Cec ThA. A 0.5 C'BORE<br>0.33<br>3.19 1.563<br>1.42<br>Figure 1. Up to 30 A<br>1.75 1.81 3.34 4.86<br>0.5 0.59 0.63 0.59 1.53 0.63 0.59 3.06 0.63<br>Fe Ta fi Tian 0.22 DIAMETER,<br>0.5 C'BORE<br>2.94 1.63<br>1.47<br>**----- End of picture text -----**<br>
Figure 2. 31 to 60 A
Data sheet no. 1116
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-37
**8 — Fuse blocks and holders**
Dimensions — in
**==> picture [249 x 203] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.69 (1 POLE)<br>3.09 (2 POLE)<br>4.5 (3 POLE)<br>0.84 1.41 (2 POLE)<br>2.81 (3 POLE)<br>X Z 0.78<br>0.22 DIA.<br>0.52 C'BORE<br>0.55 DEEP<br>2.34<br>REF<br>2.39<br>X Z<br>SECTION Z-Z<br>0.38<br>0.75<br>**----- End of picture text -----**<br>
Figure 3. 61 to 100 A
**==> picture [248 x 388] intentionally omitted <==**
**----- Start of picture text -----**<br>
6 0.05<br>3<br>1.125<br>1.25 2.25<br>2.5 0.28 DIAMETER<br>0.63 C'BORE 0.5 DEEP<br>3.06<br>2.56<br>1.94<br>0.81<br>Figure 4. 101 to 200 A (T60200-1C)<br>Ø0.2812<br>C-Bore 0.5<br>3.0 4.5<br>7.0<br>2.25<br>0.1875<br>7.75<br>**----- End of picture text -----**<br>
**==> picture [224 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
6<br>3<br>1.25 2.25<br>1.125<br>0.63<br>0.28 DIAMETER, 0.63 C'BORE 0.5 DEEP<br>2.72<br>3.06<br>2.38<br>0.81<br>**----- End of picture text -----**<br>
Figure 6. 201 to 400 A
**==> picture [221 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
6.75<br>3.38<br>1.5<br>2 3<br>0.3 DIAMETER, 0.75 C'BORE 0.5 DEEP<br>2.95<br>3.44<br>3<br>0.75<br>**----- End of picture text -----**<br>
Figure 7. 401 to 600 A
Figure 5. 101 to 200 A (1B0089)
Data sheet no. 1116
Eaton.com/bussmannseries
8-38
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## Modular open-center fuse blocks
**==> picture [28 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
## BH modular type
C5268 stud type
BH modular fuse blocks are for use with various blade and ferrule (cylindrical) Bussmann series high speed, and Class J and T fuses.
See the data sheets referenced in the catalog number table for block/fuse compatibility.
## Ratings
- Volts 700 V
- Amps
- BH-0xxx 100 A
- BH-1xxx and BH-2xxx 400 A
- BH-3xxx 700 A
The simpler design is the C5268 modular fuse block. With this design, the fuse terminal and cable (with termination) are mounted on the same stud, minimizing labor needed for installation. The stud type block is available in the configurations shown in the table below.
|Catalogno.<br>Max fuse amprating<br>Stud<br>~~eee~~|Catalogno.<br>Max fuse amprating<br>Stud<br>~~eee~~|Catalogno.<br>Max fuse amprating<br>Stud<br>~~eee~~|
|---|---|---|
|C5268-1||5/16-18 x 1"|
|C5268-2|200|5/16-18 x 1-3/4"|
|C5268-3||5/16-18 x 3/4"|
|C5268-4<br>C5268-5|100|1/4-20 x 1"<br>1/4-20 x 1-3/4"|
- SCCR 200 kA RMS Sym. or fuse IR, whichever is lower
## Agency information
- UL Recognized, Guide EZLT2, File No. E14853 up to 700 V, CSA Certified, Class 6225-01, File No. 47235 up to 700 V, RoHS compliant, CE
**==> picture [28 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
## Features
- A wide range of mounting configurations
- High Short-Circuit Current Rating (SCCR) based upon installed fuse up to 200 kA RMS Sym.
## Typical applications
- Solid state control circuits
- VFDs
- UPS systems
Refer to the data sheet numbers below for the catalog code description information.
|Cat no.|Data<br>sheet|Cat no.|Data<br>sheet|Cat no.|Data<br>sheet|Cat no.|Data<br>sheet|
|---|---|---|---|---|---|---|---|
|BH-0001||BH-1001||BH-2001||BH-3003||
|BH-0002||BH-1002||BH-2002||BH-3004||
|BH-0003||BH-1003||BH-2003||BH-3033||
|BH-0111<br>BH-0112|1200|BH-1131<br>BH-1132|1201|BH-2031<br>BH-2032|1202|BH-3144<br>BH-3145|1203|
|BH-0113||BH-1133||BH-2033||||
|BH-0121||||||||
|BH-0122||||||||
Data sheet no. 1200 (BH-0), 1201 (BH-1), 1202 (BH-2), 1203 (BH-3)
## 1BS10x connector type
Eaton's Bussmann series also offers a modular style fuse block that utilizes a tin-plated connector for wire termination and heat dissipation) with a plated-steel stud for fuse mounting. The connector type fuse block is available in the RoHS compliant configurations shown below. Consult your Bussmann series product representative for additional product details.
|Catalogno.|no.<br>Max rated voltage|Max fuse amprating|
|---|---|---|
|1BS101||100|
|1BS102<br>1BS103|600|400|
|1BS104||600|
Data sheet no. 1206 (1BS101), 1207 (1BS102), 1208 (1BS103), 1209 (1BS104)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-39
**8 — Fuse blocks and holders** ~~RT~~
## SD and TD blocks for NH size fuses
1-pole SD and 3-pole TD fuse blocks for NH fuse sizes 00 to 4 are specifically designed for use with Bussmann series bladed NH fuses. See data sheet 720109 (690 V gG/gL) and 10164 (500 V gG/gL).
**==> picture [115 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>Pr @><br>**----- End of picture text -----**<br>
For NH 1 to 3 photovoltaic fuse applications, see the single-pole SD-PV blocks in the PV fuse section.
## Ratings
- Volts
- 690 Vac
- 1000 Vac (Sd1-D only)
Shown with optional shroud kit
- Amps 160 to 1600 A
- SCCR up to 120 kA
## Agency information
- IEC 60269-1 and 2
- VDE 0636-1 and 2
- RoHS compliant
## Poles
- 1 and 3
## Protection level
- IEC - IP20 with shroud kit installed and shielding of any exposed terminal lugs
- UL - Installation of shroud kit decreases the likelihood of incidental terminal contact. To ensure compliance to IP20 specifications per UL the installer must make additional provisions.
## Temperature range
- Operating -20°C to +70°C
- Storage -40°C to +80°C
## Mounting
- 35mm DIN-Rail
- Panel
## Flammability rating
- UL 94V0
|Catalog no.<br>SD00-D<br>TD00-D<br>TD00-DI*<br>SD1-D<br>TD1-D<br>SD2-D|Poles<br>1<br>3<br>1<br>3<br>1|Description<br>NH fuse size<br>NH fuse block<br>000 and 00<br>1|Amps<br>160<br>250|
|---|---|---|---|
|||2|400|
|TD2-D|3|||
|SD3-D|1|||
|||3|630|
|TD3-D|3|||
|SD4-D|||1250|
|SD4-S1600**|1|4|1600|
- 3-pole integral base molding.
- ** Panel mount only.
## Accessories
## Fuse extraction handle
|Catalog no.|Size||Amps|Amps|
|---|---|---|---|---|
|FEH|NH00 to 3|NH00 to 3|160 to 630|160 to 630|
|Shroud kits|||||
|Catalog no.†|Fuse block|Fuse size|Amps|Description|
|SD12-SK|SD1/TD1|NH1|250|Includes 2|
|SD12-SK|SD2/TD2|NH2|400|shrouds and 1|
|SD3-SK|SD3/TD3|NH3|630|fuse cover|
- Order one kit per pole.
## Phase barrier kits
|Catalog no.††|Fuse block|Fuse size|Amps|Description|
|---|---|---|---|---|
|SD00-PB|SD00/TD00|NH00|160||
|SD12-PB|SD1/TD1|NH1|250|2 phase barriers|
|SD12-PB|SD2/TD2|NH2|400|and 2 ganging<br>links|
|SD3-PB|SD3/TD3|NH3|630||
†† Order one kit per 3-pole assembly.
## Microswitches
|Catalog no.||Ratings|
|---|---|---|
|BVL50||6 A 250 Vac|
|170H0236||2 A 250 Vac|
|170H0238||2 A 250 Vac|
|Neutral links|||
|Catalog no.|Fuse size|Amps|
|SDL-00|NH00|160|
|SDL-1|NH1|250|
|SDL-2|NH2|400|
|SDL-3|NH3|630|
## Neutral links
Data sheet no. 10163
Eaton.com/bussmannseries
8-40
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## HTB panel mount fuse holders for 5x20mm and 1/4" x 1-1/4" fuses
Panel mount holders with knobtype and screwdriver-type carriers made from high temperature, flame retardant thermoplastic (UL 94V0) and tin-plated brass quick-connect terminals.
**==> picture [99 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
Knob-type fuse carrier<br>Screwdriver-type<br>fuse carrier<br>2011/65/EU<br>**----- End of picture text -----**<br>
## Ratings*
Volts 250 V
Amps 20 A max*
- Insulation resistance (per IEC #257) 10,000 ohms @ 500 Vdc
## Agency information
- UL Recognized, Guide IZLT2, File E14853, 1/4" dia. fuse @ 20 A, 5mm dia. fuse @16 A @ 250 V, CSA Class 6225-01 File 47235 @ 16 A @ 250 V, VDE Certified, 136128, HTB-XXM, SEMKO Certification, Ref. 0146149/01, HTB-XXM, RoHS compliant, CE
## Operating temperature range
- -55°C to +85°C
## Mounting
- Rear hex nut; HTB-2_, HTB3_, HTB-4_, HTB-5_
- Front hex nut; HTB-6_
- Snap-in; HTB-8_, HTB-9_
- Contact resistance (per IEC #257) 0.005 ohms max @ 1 A
- Standoff voltage (per IEC #257) 480 V/Mil @ 0.125” thickness
- See data sheet 2119 for ratings by holder configuration.
## Splash-proof versions
- Splash-proof versions available by adding "-SP" suffix to the catalog number.
Catalog numbers and dimensions — in (mm)
**==> picture [547 x 431] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Solder / 3/16" QC terminal|1/4" QC terminal|Fuse carrier*|
|Max|
|panel|
|thickness|
|— in|0.34|0.33|0.47|0.45|1/4"|5mm|
|Holder dimensions|(mm)|In-line(8 7)|Rt. angle(8 3)|In-line(11 9)|Rt. angle(11.5)|I = inches|M = metric|
|Knob-type carrier — common length 1.69 (43)|
|[=|
|0.47|1.125|
|(11.9)|(28.6)|HTB-22I-R|HTB-24I-R|HTB-26I-R|HTB-28I-R|X|
|0.3 (8)|
|0.09 NOM.|HTB-22M-R|HTB-24M-R|HTB-26M-R|HTB-28M-R|X|
|(2.4)|
|(17.5)0.69|(23.0)0.91|HTB-42I-R|HTB-44I-R|HTB-46I-R|HTB-48I-R|X|
|4|
|0.125 (3)|
|__|HTB-42M-R|HTB-44M-R|HTB-46M-R|HTB-48M-R|X|
|(17.1)0.67|(23.4)0.92|HTB-62I-R|HTB-64I-R|HTB-66I-R|HTB-68I-R|X|
|alin|
|0.3 (8)|
|HTB-62M-R|HTB-64M-R|HTB-66M-R|HTB-68M-R|X|
|0.47(11.9)|1.125(28.6)|HTB-82I-R|HTB-84I-R|HTB-86I-R|HTB-88I-R|X|
|-|0.125 (3)|a|
|HTB-82M-R|HTB-84M-R|HTB-86M-R|HTB-88M-R|X|
|Screwdriver-type carrier — common length 1.75 (45)|
|[|-|EE|
|0.17|1.58|
|(4.37)|(40.03)|HTB-32I-R|HTB-34I-R|HTB-36I-R|HTB-38I-R|X|
|0.3 (8)|
|HTB-32M-R|HTB-34M-R|HTB-36M-R|HTB-38M-R|X|
|(10.31)0.41|(34.13)1.34|HTB-52I-R|HTB-54I-R|HTB-56I-R|HTB-58I-R|X|
|0.125 (3)|
|HTB-52M-R|HTB-54M-R|HTB-56M-R|HTB-58M-R|X|
|0.17|1.59|HTB-92I-R|HTB-94I-R|HTB-96I-R|HTB-98I-R|X|
|(4.37)|(40.08)|
|0.125 (3)|
|HTB-92M-R|HTB-94M-R|HTB-96M-R|HTB-98M-R|X|
**----- End of picture text -----**<br>
- Fuse carriers may be ordered separately. Specify "FT" for knob-type or "ST" for screwdriver type, followed by "-I" for 1/4" fuses and "-M" for 5mm fuses.
Data sheet no. 2119
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-41
## **8 — Fuse blocks and holders**
HJL panel mount neon lamp indicating holder for 1/4" x 1" fuses
## Ratings
- Volts 250 V
- Amps 15 A
**==> picture [232 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog no.* Volts Lamp color Knob type<br>HJL 90 to 250 Clear Octagonal<br>**----- End of picture text -----**<br>
## HKP panel mount holders for 1/4" x 1-1/4" fuses
Vibration resistant bayonet-type knob holders for panels up to 5/16" thick.
**==> picture [62 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
HKP,<br>HKP-L, HKP-W<br>HKP-BBHH,<br>HKP-HH, HKP-LW-HH<br>**----- End of picture text -----**<br>
## Ratings
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- Volts 250 V
- Amps up to 30 A*
- See data sheet 2106 for ratings by specific holder.
- Use with AGX, MKB, TCP70 and TDC fuses, for panels up to 1/8" thick.
## Dimensions — in (mm)
**==> picture [215 x 72] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.81<br>1.19 (71) Punched mounting<br>(30) hole<br>0.81 0.63<br>(21) (16)<br>N = y) yoe{ me<br>Octagonal 0.590<br>sides (15)<br>**----- End of picture text -----**<br>
## Data sheet no. 2121
HK panel mount neon and incandescent lamp indicating holders for 1/4" x 1" fuses
## Agency information
**==> picture [25 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
HKP-OO<br>**----- End of picture text -----**<br>
> • UL Recognized Guide IZLT2, File E14853, CSA Certified, Class 6225-01, File 47235, CE (HKP, HKP-L, HKP-W, HKP-OO), RoHS compliant Catalog no. Description ~~ee~~ HKP-R Standard fuse holder HKP-L-R HKP with 2250 V stand-off barrier HKP-W-R HKP with drip-proof knob HKP-BBHH-R HKP with 1/4" quick-connects, nut and washer assembled. HKP-HH-R HKP with 1/4" quick-connect. HKP-LW-HH-R HKP with drip-proof knob, 2250 V stand-off barrier and 1/4" quick-connects. HKP-OO-R HKP with snap-lock
## Ratings
## Replacement parts
- Volts 250 V
- Amps
- 15 A (HKL, HKL-X)
- 20 A (HKR, HKT, HKU, HKX)
## Agency information
- UL Recognized, Guide IZLT2, File E14853), CSA Certified Class 6225-01, File 47235, CE
||Catalog no.<br>HKL*|Lamp volts<br>90-250|Knob color/type<br>Clear/octagonal|
|---|---|---|---|
||HKL-X*|90-250|Clear/flat side|
||HKR**|22-30|Amber/octagonal|
|HKT**<br>~~TT~~||13-22|Amber/octagonal|
||HKU**|4-6|Red/octagonal|
||HKX**|22-33|Amber/flat side|
- Neon lamp UL Recognized and CSA Certified.
- ** Incandescent lamp.
## Dimensions — in (mm)
**==> picture [260 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.81<br>(71)<br>1.19 Punched mounting<br>(1) (30) hole<br>Flat sides<br>y) a ana _<br>0.81 0.630<br>7, I (21) “ (16) |<br>0.573<br>(15)<br>© Octagonal c E<br>sides<br>**----- End of picture text -----**<br>
Data sheet no. 2105
|Catalog no.|Description|
|---|---|
|||
|9435-1/2|Cap|
|BK/1A4287|Plastic nut (100 pieces minimum)|
|BK/1A4806-2|Metal nut (100 pieces minimum)|
|9732|Washer|
Dimensions — in (mm)
**==> picture [211 x 185] intentionally omitted <==**
**----- Start of picture text -----**<br>
HKP-R, HKP-L-R, HKP-W-R (120mm)<br>HKP-BBHH-R, HKP-HH-R, HKP-LW-HH-R Punched [Mi] vii [i] ~a [Hol]<br>0.75 1.56 Punched<br>uncl (19) lounting Hole (40) ril e lounting mounting hole Hole<br>= 0.855(22) I 1.17 Z | | a 0.89(23)<br>HKP-OO-R OM: (20)0.8 = J6ll 0.81(21)<br>FUSE FUSE<br>ESUF<br>**----- End of picture text -----**<br>
Data sheet no. 2106
Eaton.com/bussmannseries
8-42 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## TBST
HLD panel mount holders for 1/4" x 1-1/4" pin indicating fuses
## Ratings
- Volts 250 V
- Amps 15 A
Agency information
> • UL Recognized, Guide IZLT2, File E14853, CE
~~ee~~ Catalog no.* Terminals HLD Solder terminals HLD-HH 1/4" quick-connect terminals
- Use with GBA or GLD fuses.
HPF panel mount holders with screw-type knobs for 13/32" x 1-5/16" to 1-1/2" fuses
Ratings*
- Volts up to 600 V
- Amps up to 30 A
- See catalog numbers for ratings by specific holder.
Agency information
- UL Recognized, Guide IZLT2, File E14853; CSA Certified, Class 6225-01, File 47235, CE
Flammability rating: UL 94HB
Dimensions — in (mm)
## Terminals
|Dimensions — in (mm)|Dimensions — in (mm)|Dimensions — in (mm)|Dimensions — in (mm)||||Terminals|Terminals|Terminals|
|---|---|---|---|---|---|---|---|---|---|
||||2.5 Max. (HLD)<br>(64 Max.)<br>0.86||||• Combination 1/4" quick-connect/solder** terminals|||
||||(22)<br>Washer||Punched||** Solder terminal 10 AWG wire max.|** Solder terminal 10 AWG wire max.||
||||||mounting hole|||||
|Octagonal|0.69<br>(18)||2.75 Max. (HLD-HH)||0.505<br>(16)<br>0.473<br>(12)<br>Catalogno.<br>Amps<br>Volts(AC)<br>Fuse/description/length<br>HPF<br>302<br>600<br>1-1/2"(38mm)<br>HPF-C<br>303<br>6003<br>Clear knob 1-1/2"(38mm)<br>HPF-L<br>5<br>600<br>BBS,1-3/8" fuses.<br>~~—=~~|||||
|sides|||(70 Max.)||||HPF-EE|15<br>600|SC Class G upto 15 A,1-5/16"|
||||||Data sheet no. 2120||HPF-JJ<br>HPF-FF1|20<br>600<br>302<br>480|SC Class G 20 A,1-13/32"<br>SC Class G 25 and 30 A,1-5/8"|
|HPC-D flange panel mount, solder terminal|HPC-D flange panel mount, solder terminal||||||HPF-RR|302<br>600|FNQ-R,KTK-R,LP-CC,Class CC|
|10 AWG max holder with screw-type knob for 13/32" x 1-1/2" fuses.|10 AWG max holder with screw-type knob for 13/32" x 1-1/2" fuses.|10 AWG max holder with screw-type knob for 13/32" x 1-1/2" fuses.|10 AWG max holder with screw-type knob for 13/32" x 1-1/2" fuses.|10 AWG max holder with screw-type knob for 13/32" x 1-1/2" fuses.|10 AWG max holder with screw-type knob for 13/32" x 1-1/2" fuses.|10 AWG max holder with screw-type knob for 13/32" x 1-1/2" fuses.|HPF-WT|302<br>600|Splash-proof knob. 1-1/2"(38mm)|
## HPC-D flange panel mount, solder terminal
10 AWG max holder with screw-type knob for 13/32" x 1-1/2" fuses. Supplied with O-ring and panel gasket
- 1 Not CSA Certified.
- 2 20 A max when used with quick-connect terminals.
- 3 HPF-C ratings for CSA: 15 A, 250 V.
## Ratings
Dimensions — in (mm)
- 600 V, 30 A*
- 20 A max when used with quick-connect terminals.
## Agency information
- UL Recognized, Guide IZLT2, File E14853, CE
Flammability rating: UL 94HB
~~SSS~~ Catalog no. Description HPC-D Flange mount in panels up to 1/4" thick. BK/9987SA Replacement knob, bulk only, 50 pieces
**==> picture [164 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
With fuse<br>2.81 Max.<br>(71)<br>1.0 1.31 1.78<br>(25) (33) (45)<br>Ø 0.180 0.88(22)<br>1.125 (5) 2.69 Max.<br>(29) Without fuse (68) 0.250<br>(6)<br>(Typ.2)<br>FUESSEUFFUES<br>**----- End of picture text -----**<br>
Dimensions — in (mm)
**==> picture [173 x 132] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.120<br>(30.5) 0.88<br>(22.2)<br>1.775<br>(45.1)<br>With fuse<br>0.180(4.6) 2.48 (63.1)<br>0.187<br>(4.75)<br>1.031 0.89<br>(26.2) (22.6)<br>Mounting hole<br>1.312 1.312<br>(33.3) (33.3)<br>Or rear of panel O front of panel r<br>**----- End of picture text -----**<br>
Data sheet no. 2109
Data sheet no. 2114
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-43
**8 — Fuse blocks and holders** ~~I~~ Cc HPD and HPG panel mount bayonet-type knob HPM panel mount holders with screw-type knob holders for 13/32" x 1-1/2" fuses for 13/32" x 1-1/2" fuses.
Ratings
## Ratings
Volts 600 V
- Volts 600 V
Amps 30 A*
- Amps
- 20 A max when used with quick-connect terminals.
- 30 A
**==> picture [14 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
HPD<br>**----- End of picture text -----**<br>
- 15 A (Class G only)
Agency information
Agency information
- UL Recognized, Guide IZLT2, File E14853; CSA Certified, Class 6225-01, File 47235, CE
- UL Recognized, Guide IZLT2, File E14853, CE
Flammability rating: UL 94HB
~~|~~ Catalog no. Description HPM 1/4" quick-connect/solder HPM-D Splash-resistant knob** BK/9789-Y2 Replacement knob, bulk only, 50 pieces ~~co~~ ** HPM-D has 1/4" quick-connect/solder terminal on rear (load) terminal only. The side (line) terminal is 1/4" quick-connect only.
Flammability ratings
HPG, HPG-EE
- Body UL 94V0
- Knob UL 94HB
BK/9789-Y2 ~~a~~ Catalog no. Amps Volts (AC) Fuse/description/length ~~co~~ HPD* side (line) terminal is 1/4" quick-connect only. 30[1] 1-1/2" (38mm) HPG** 600 Nut torque: HPG-EE** 15 SC Class G up to 15 A, 1-5/16"
- 30 lb-in.
- HPD has combination 1/4" quick-connect/solder terminal on loadside (side) terminal only. Lineside (rear) terminal is 3/16" shorter than and is solder only.
- ** HPG and HPG-EE has combination 1/4" quick-connect/solder terminals on both side (load) and rear (line) terminals.
Dimensions — in (mm)
- 1 20 A max when used with quick-connect terminals.
**==> picture [176 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
With fuse<br>2.73<br>(69.5)<br>0.94<br>(23.8)<br>1.41<br>(30.6)<br>2.594<br>(65.89)<br>oF le Without fuse 0.250<br>(6.35)<br>**----- End of picture text -----**<br>
Dimensions — in (mm)
**==> picture [261 x 132] intentionally omitted <==**
**----- Start of picture text -----**<br>
HPD<br>©« O 2.81 l<br>(71)<br>0.88<br>(22) Punched mounting hole<br>1.125 0.88<br>(28.6) (22)<br>©. _ 0.815<br> dj=- ©: (21)<br>HPG, HPG-EE<br>**----- End of picture text -----**<br>
Data sheet no. 2108
Data sheet no. 2112
Eaton.com/bussmannseries
8-44
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
HPS panel mount bayonet-type knob holders for 13/32" x 1-5/16" to 1-1/2" fuses
## Ratings*
HPS2 panel mount, 1/4" quick-connect/solder terminal (10 AWG max) holder with screw-type knob for 13/32" x 1-1/2" fuses. Supplied with O-ring and panel gasket
- Volts up to 600 V
- Amps up to 30 A
- See catalog numbers for ratings by specific holder.
Agency information
- UL Recognized, Guide IZLT2, File E14853; CSA Certified, Class 6225-01, File 47235, CE
For fuse size 13/32" x 1-1/2", meeting UL 1598 requirement that both poles be removed simultaneously.
## Ratings
Volts 600 V
Amps 30 A*
Flammability rating: UL 94HB
## Terminals
- Combination 1/4" quick-connect/solder terminals.
|Catalogno.<br>HPS|Amps<br>301 2|Volts(AC)<br>600|Fuse/description/length<br>1-1/2"(38mm)|
|---|---|---|---|
|HPS-L|5|600|BBS,1-3/8"|
|HPS-EE*|15|600|SC Class G upto 15 A,1-5/16"|
|HPS-JJ*<br>HPS-F-EE†|20<br>15|600<br>600|SC Class G 20 A,1-13/32"<br>Sleeve on body, leaded for 1-5/16"<br>fuses|
|HPS-FF*†|301|480|SC Class G 25 and 30 A,1-5/8"|
|HPS-RR*†|301|600|FNQ-R KTK-R,LP-CC Class CC|
- 20 A max when used with quick-connect terminals.
## Agency information
- UL 4248 Recognized, Guide IZLT2, File E14853, CSA certified Class 6225-01, File 47235
## Flammability rating: UL 94V0
Terminals: 1/4” quick-connect/solder.
|Terminals: 1/4” quick-connect/solder.||
|---|---|
|Catalog no.|Description|
|HPS2|Standard 10-in carton|
|BK/HPS2|Bulk 100-in carton|
Dimensions — in (mm)
- -EE, -JJ, -FF and -RR suffix versions are UL Recognized for applications requiring branch circuit protection.
- Not CSA Certified.
- 1 20 A max when used with quick-connect terminals.
- 2 HPS rated at 250 V for CSA.
## Dimensions — in (mm)
**==> picture [201 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
With fuse<br>2.81<br>0.88 (71)<br>(22)<br>JO<br>0.250<br>1.78(45) = (Typ.2)(6)<br>Noy— 0.180 z| | 0.80 feo jo o<br>(5) (20)<br>— 1.125 2.41<br>(64)<br>(29) Without fuse<br>**----- End of picture text -----**<br>
Data sheet no. 2113
Data sheet no. 2140
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-45
**8 — Fuse blocks and holders**
## HHT in-line fuse holder for 5x15mm to 20mm fuses
## HFA in-line water-resistant holders for 1/4" x 1-1/4" fuses
The HHT features a black thermoplastic body with brass contacts and 13 inch red AWG 16 leads.
## Ratings
- Volts
- 250 Vac
The HFA is a waterproof, crimp or quick-connect terminal holder for exposed locations made of high temperature, flame retardant phenolic material meeting UL 94 HB. Recommended crimp tools include Thomas & Betts WT-112M or ERG-2002 and Channelock No. 909.
## Ratings
- 32 Vdc
- Volts 250 V
- Amps
- Amps 20 A max.
- 5 A (5x15mm fuses)
Agency information
- 10 A (5x20mm fuses)
- UL Recognized, Guide IZLT2, File E14853 using AWG 12 copper conductors
**==> picture [181 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Catalog no.|Fuse size (mm)|
|HHT (100-in)|
**----- End of picture text -----**<br>
5x15 and 5x20
- ~~C~~ BK/HHT (1000-in) ~~EO~~ Catalog no. Terminals/AWG
**==> picture [229 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Catalog no.|Terminals/AWG|
|HFA (10-in)|
|HFA-R (10-in, RoHS compliant)|Crimp/12-16|
|BK/HFA-R (20-in, RoHS compliant)|
|HFA-HH* (10-in)|
|HFA-HH-R* (10-in, RoHS compliant|1/4" quick-connect|
|BK/HFA-HH-R* (20-in, RoHS compliant|
**----- End of picture text -----**<br>
**==> picture [240 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in<br>S 0.25 C Joe =<br>6.181 0.88 0.99 6.063<br>WIRE LENGTH: 13<br>0.42 DIA.<br>1.87<br>**----- End of picture text -----**<br>
* Not UL Recognized.
Dimensions — in
Data sheet no. 2138
Data sheet no. 2115
Eaton.com/bussmannseries
8-46
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
HFB and HFB-10 in-line holders for 1/4" x 7/8" to 1-1/4" fuses
HHB universal in-line holders for 1/4" x 7/8", 1" and 1-1/4" fuses
Water-resistant in-line fuse holder for 1/4" x 1-1/4" fuses made of a thermoplastic rubber body with tin-plated, copper contacts.
Universal in-line fuse holder for 1/4" diameter fuses in lengths from 7/8" to 1-1/4" made of a nylon body with tin-plated, copper contacts.
## Ratings
## Ratings
- Volts 32 V
- Volts 32 V
- Amps 30 A max.
> • Amps 30 A max.
|Catalog no.|Description<br>~~ee~~|Description<br>~~ee~~|Catalog no.<br>Description<br> ~~eee~~|Catalog no.<br>Description<br> ~~eee~~|
|---|---|---|---|---|
|HFB-R*|Standard pack (10-in)||Holder without leads*||
|BK/HFB-R*|Bulk pack (100-in)||HHB-R**|Standard pack (10-in)|
|HFB-10-R**|Standard pack (10-in)||BK/HHB-R**|Bulk pack (1000-in)|
|BK/1A2294|HFB replacement contact clip||Holder with pre-attached 14 AWG insulated lead wires||
|1A2294-01|HFB-10** replacement contact clip||BK/HHB-Y408|8" yellow leads (1000-in)|
|Catalog no.<br>~~eee~~|Description<br>~~eee~~|
|---|---|
|Holder without leads*<br>~~eee~~|~~eee~~|
|HHB-R**|Standard pack (10-in)|
|BK/HHB-R**|Bulk pack (1000-in)|
|Holder with pre-attached 14 AWG insulated lead wires||
|BK/HHB-Y408|8" yellow leads (1000-in)|
|BK/HHB-R408**<br>BK/HHB-B408|8" red leads (1000-in)<br>8" black leads (1000-in)|
|BK/HHB-Y419|19" yellow leads (1000-in)|
|BK/HHB-R419|19" red leads (1000-in)|
|BK/HHB-B419|19" black leads (1000-in)|
- HFB-R accepts #12 to #18 wire leads (not provided). See data sheet 2102 for recommended crimp tools.
- ** HFB-10-R accepts #10 wire leads (not provided). See data sheet 2102 for recommended crimp tools.
## Features
- Simple assembly with one-piece thermoplastic (important information molded into body)
- Accepts #12 to #16 wire leads (not provided with basic fuse holder). See data sheet 2103 for recommended crimp tools.
- ** RoHS compliant.
- High visibility yellow color for easy identification in dark or hard-toaccess locations
Flammability rating: UL 94V2
- Ideal for shock and vibration environments; withstands many organic solvents; temperature range -40°C to +150°C
## Pull force
## Typical applications
- 5 lbs minimum to separate fuse holder housing with fuse installed
- Supplemental, low voltage, low amperage control circuits
## Features
Dimensions — in (mm)
- Universal application for 1/4" x 7/8", 1" and 1-1/4" fuses
**==> picture [166 x 62] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>(76.2)<br>0.75<br>(19.1)<br>“(pa<br>**----- End of picture text -----**<br>
## Typical applications
- Supplemental, low voltage, low amperage control circuits
Dimensions — in (mm)
|Dimensions — in (mm)|Dimensions — in (mm)|Dimensions — in (mm)|Dimensions — in (mm)|
|---|---|---|---|
|Fuse length<br>Fuse<br>Max. holder length “L”<br>7/8"<br>AWG<br>2.10<br>1"<br>AGX<br>2.25<br>L<br>0.53<br>(13.5)<br>(~~K~~=O<br>fw |||||
|1-1/4"||ABC, AGC, GBB,<br>MDA, MDL, MDQ<br>2.42||
Data sheet no. 2102
Data sheet no. 2103
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-47
**8 — Fuse blocks and holders** TONusage
## HM, HR and HH in-line holders
HM and HR in-line fuse holders feature 8 and 19 inch 14 AWG length leads with a size-rejecting SFE fuse. Also accommodates various length 1/4" diameter fuses from 5/8" to 1-1/4".
## Ratings
- Volts 32 V
> • Amps 20 A max.
|Catalog no.<br>Included SFE fuse<br>Lead length<br>(in)<br>Fuse length<br>(in)<br>HMJ*<br>SFE-20<br>1-1/4<br>HMI<br>SFE-14<br>1-1/16<br>~~aa~~<br>~~—=~~|Catalog no.<br>Included SFE fuse<br>Lead length<br>(in)<br>Fuse length<br>(in)<br>HMJ*<br>SFE-20<br>1-1/4<br>HMI<br>SFE-14<br>1-1/16<br>~~aa~~<br>~~—=~~|Catalog no.<br>Included SFE fuse<br>Lead length<br>(in)<br>Fuse length<br>(in)<br>HMJ*<br>SFE-20<br>1-1/4<br>HMI<br>SFE-14<br>1-1/16<br>~~aa~~<br>~~—=~~|
|---|---|---|
|HMH|SFE-9|8<br>7/8|
|HME|SFE-7-1/2|7/8|
|HMG|SFE-6|3/4|
|HMF|SFE-4|5/8|
|HRJ**|SFE-20|1-1/4|
|HRI|SFE-14|1-1/16|
|HRH|SFE-9|7/8|
|HRE|SFE-7-1/2|19<br>7/8|
|HRG|SFE-6|3/4|
|HRF|SFE-4|5/8|
- Also available as in-line fuse holder only with lead wire contacts, HMJ-LESS-fuse.
- ** Also available as in-line fuse holder only with lead wire contacts, HRJ-LESS-fuse.
|Catalog no.<br>Fuse<br>length (in)<br>Holder<br>description<br>AWG wire<br>range<br>Max amps<br>~~aa~~|Catalog no.<br>Fuse<br>length (in)<br>Holder<br>description<br>AWG wire<br>range<br>Max amps<br>~~aa~~|Catalog no.<br>Fuse<br>length (in)<br>Holder<br>description<br>AWG wire<br>range<br>Max amps<br>~~aa~~|Catalog no.<br>Fuse<br>length (in)<br>Holder<br>description<br>AWG wire<br>range<br>Max amps<br>~~aa~~|
|---|---|---|---|
|HHJ-A||18-22|10|
|HHJ-B|1-1/4<br>No wire or|12-16|30|
||fuse includ-|||
|HHI-A|ed|18-22|10|
||1-1/16|||
|HHI-B||12-16|30|
|Replacement contacts<br>Contact catalog no.<br>For holder catalog no.<br>~~_EEEEEE~~||||
|9838|HHJ-A and HHI-A|HHJ-A and HHI-A||
|9841|HHJ-B and HHI-B|HHJ-B and HHI-B||
HRK Universal in-line holder for 1/4" x 7/8" to 1-1/4" fuses
Universal in-line fuse holder with **2011/65/EU** 8" (203mm) 14 AWG lead wires for 1/4" diameter fuses in lengths from 7/8" to 1-1/4".
## Ratings
- Volts 32 V
- Amps 15 A max.
|Catalog no.|Catalog no.<br>Accepts fuse<br>length|Accepts fuse<br>Fuse<br>~~—~~|
|---|---|---|
|||~~— ~~|
||7/8"|AWG|
|HRK-R*|1"|AGX|
||1-1/4"|ABC, AGC, GBB, MDA, MDL, MDQ|
- Three springs furnished with fuse holder to accommodate different length 1/4" fuses.
## Features
- Universal application for 1/4" x 7/8", 1" and 1-1/4" fuses
- 14 AWG lead wires simplify electrical connection.
- RoHS compliant
## Typical applications
- Supplemental, low voltage, low amperage control circuits
## Dimensions — in (mm)
**==> picture [183 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.19<br>(55.6)<br>0.75<br>(19.1)<br>0.69<br>(17.5)<br>1.56 0.38<br>(39.7) (9.5)<br>+—_ S L)<br>**----- End of picture text -----**<br>
## Features
- Universal application for SFE and various length 1/4" diameter fuses.
- 14 AWG lead wires simplify electrical connection.
## Typical applications
- Supplemental, low voltage, low amperage control circuits
Dimensions — in (mm)
**==> picture [143 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.19<br>(55.6)<br>0.75<br>(19.1)<br>0.69<br>(17.5)<br>g eo<br>1.56 0.38<br>(39.7) (9.5)<br>**----- End of picture text -----**<br>
Data sheet no. 2111
Data sheet no. 2122
Eaton.com/bussmannseries
8-48
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## HEC, HEG, HEH and HEJ[†] single-pole Class G fuse non-breakaway in-line holders
Class G size-rejecting non-breakaway submersible, single-pole in-line fuse holders available with many terminal options to meet application needs. Optional insulating boots provide additional protection from dust and moisture ingress (order separately). The HEC is also available in a breakaway version.
† HEJ holders are not RoHS compliant. **2011/65/EU**
## Ratings*
Volts up to 600 V Amps up to 60 A SCCR 200 kA RMS Sym.
* Dependant upon fuse and conductor rating.
## Insulating boots
Insulating boots are not included. Two insulating boots must be ordered separately, if required, for each holder ordered. When insulating boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200 percent of the RMS load current.
## Recommended crimping tools
This list is not intended to exclude the use of other crimping tools that can provide similar crimps or indents.
|Terminal code|T & B P/N (Die)|Terminal code|T & B P/N (Die)|
|---|---|---|---|
|A|WT-111M (C)||TBM5 (Brown)|
||Sta-Kon ERG4002 (C)|D|TBM8 (Brown)|
|B<br>C|WT-115A (D)<br>TBM5 (Grey)|Z|WT-115A (F)<br>WT-111M (A)|
||WT-115A (E)||Sta-Kon ERG4002 (A)|
|N, P, Q, R, T|TBM8 (Orange)|||
## HET neutral
The HET holder is a single-pole in-line holder with a permanent, solid neutral for use along with the Class G in-line holders to provide a means of conductor continuity. The HET holder is identified by a white, plastic coupling nut. Available HET holder counterparts to their Class G holder equivalents are listed in the following catalog number tables. See data sheet no. 2125 for details on the HET holder.
To order insulating boots for Class G holders, use these catalog numbers.
|Catalog no.|Catalog no.<br>Description|
|---|---|
|2A0660|Single conductor|
|2A0661|Dual conductor|
**==> picture [165 x 43] intentionally omitted <==**
**----- Start of picture text -----**<br>
HEG HEH<br> • 600 V • 600 V<br> • 15 A • 20 A<br>**----- End of picture text -----**<br>
HEC breakaway Class G fuse in-line holder
HEC breakaway Class G fuse in-line holder • 600 V • 600 V • 15 A • 20 A v Ne The HEC breakaway holder includes insulating boots. HEC HEJ Amps Catalog no. Line and load terminal AWG • 480 V • 480 V 25-30 HEC-RW-RLB-R Al crimp 1-2 str. • 25-30 A • 35-60 A ~~YY~~
Data sheet no. 2123 (HEJ), 2124 (HEC, HEG, HEH)
Eaton.com/bussmannseries 8-49
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**8 — Fuse blocks and holders**
Non-breakaway catalog number system
## HE_ - A A
**==> picture [538 x 42] intentionally omitted <==**
**----- Start of picture text -----**<br>
Loadside terminal Lineside terminal<br>Terminal type AWG Wire range* Terminal type AWG wire range* HET neutral equivalent<br>Amps Catalog symbol Loadside terminal Lineside terminal<br>**----- End of picture text -----**<br>
|15<br>HEG|A|A<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>8-16; (2) 12-16<br>HET-AA|
|---|---|---|
|20<br>HEH|A|A<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>8-16; (2) 12-16<br>HET-AA|
|||D<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>2 str; (2) 6<br>—|
|25-30<br>HEC|A|A<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>8-16; (2) 12-16<br>HET-AA|
|35-60<br>HEJ|A|A<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>8-16; (2) 12-16<br>HET-AA|
|||B<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>6; (2) 10<br>HET-AB|
||B|B<br>Cu crimp<br>6; (2) 10<br>Cu crimp<br>6; (2) 10<br>HET-BB|
||C|C<br>Cu crimp<br>4 str; (2) 8<br>Cu crimp<br>4 str; (2) 8<br>—|
||D|D<br>Cu crimp<br>2 str; (2) 6<br>Cu crimp<br>2 str; (2) 6<br>—|
||J|J<br>Cu setscrew<br>3-12<br>Cu setscrew<br>3-12<br>HET-JJ|
|||K<br>Cu setscrew<br>3-12<br>Cu dual setscrew<br>2-12†<br>HET-JK|
||L|L<br>Al setscrew<br>2-12<br>Al setscrew<br>2-12<br>—<br>LB††|
||P|P<br>Al crimp<br>4 sol; 6 str<br>Al crimp<br>4 sol; 6 str<br>—|
||Q|Q<br>Al crimp<br>2 sol; 3-4 str<br>Al crimp<br>2 sol; 3-4 str<br>—|
||W|W<br>Cu solid<br>-<br>Cu solid<br>-<br>—|
- Solid/stranded conductors unless otherwise noted.
- Not dual wire rated. One wire per opening.
- †† Same as catalog number as HEJ-LL, but packaged with two 2A0660 single conductor insulating boots.
To order: specify catalog symbol and the loadside terminal code. Then select a lineside terminal code that is available with the loadside terminal. Example: HEJ-BB defines a non-breakaway holder with a loadside copper crimp terminal for a single #6 or two #10 wires with a lineside copper crimp terminal for a single #6 or two #10 wires.
Data sheet no. 2123 (HEJ), 2124 (HEC, HEG, HEH)
Eaton.com/bussmannseries
8-50
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8**
## HEB single-pole breakaway and non-breakaway in-line holders for 13/32" x 1-1/2" supplemental fuses
Breakaway and non-breakaway submersible, single-pole in-line fuse holders available with many terminal options to meet application needs. Breakaway versions come with insulating boots to provide submersibility per UL IP67. Nonbreakaway versions require ordering optional insulating boots for submersibility.
## Ratings
**==> picture [29 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
## Insulating boots
Two insulating boots come standard with the breakaway holder configurations. Insulating boots are not included as standard with non-breakaway holders. Two insulating boots must be ordered separately, if required, for each non-breakaway holder ordered. When insulating boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200 percent of the RMS load current.
To order insulating boots for a non-breakaway HEB holder, use these catalog numbers.
|Catalog no.|Catalog no.<br>Description|
|---|---|
|2A0660|Single conductor|
|2A0661|Dual conductor|
## Recommended crimping tools
Volts 600 V
Amps up to 30 A limited by conductor size
This list is not intended to exclude the use of other crimping tools that can provide similar crimps or indents.
SCCR 200 kA RMS Sym.*
* Dependant upon fuse interrupting rating.
## Agency information
UL Recognized, Guide IZLT2, File E14853, CSA Certified, Class 622501, File 47235, CE, RoHS compliant**
** See data sheet 2127 for exceptions.
|Terminal code|T & B P/N (Die)|Terminal code|T & B P/N (Die)|
|---|---|---|---|
|A|WT-111M (C)<br>Sta-Kon ERG4002 (C)|D|TBM5 (Brown)<br>TBM8 (Brown)|
|B|WT-115A (D)||WT-115A (F)|
|C|TBM5 (Grey)<br>WT-115A (E)|Z|WT-111M (A)<br>Sta-Kon ERG4002 (A)|
|N, P, Q, R, T|TBM8 (Orange)|||
## HET neutral
The HET holder is a single-pole in-line holder with a permanent, solid neutral for use along with the HEB holder to provide a means of conductor continuity. The HET holder is identified by a white, plastic coupling nut. Available HET holder counterparts to their HEB equivalents are listed in the following catalog number tables. See data sheet no. 2125 for details on the HET holder.
## Breakaway catalog number system
||||
|---|---|---|
|Catalog<br>symbol<br>Loadside<br>terminal<br>Lineside<br>terminal<br>AgencyInformation<br>Loadside terminal<br>UL<br>CSA<br>Terminal type<br>AWG wire range*||Lineside terminal<br>HET neutral<br>equivalent<br>Terminal type<br>AWG wire range*|
|HEB<br>A<br>RLC-A<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>RLC-B<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>RLC-C<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>RLC-J<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>RYC<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>RLA<br>—<br>—<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>RYA<br>—<br>—<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>B<br>RLC-A<br>X<br>X<br>Cu crimp<br>6; (2) 10<br>RLC-B<br>X<br>X<br>Cu crimp<br>6; (2) 10<br>RYC<br>X<br>X<br>Cu crimp<br>6; (2) 10<br>J<br>RLC-J<br>X<br>X<br>Cu setscrew<br>3-12 Str; 10-12 Sol<br>RYC<br>X<br>X<br>Cu setscrew<br>3-12 Str; 10-12 Sol<br>K<br>RLC-J<br>X<br>—<br>Cu dual setscrew<br>2-12 Str†; 10-12 Sol†<br>RYC<br>X<br>—<br>Cu dual setscrew<br>2-12 Str†; 10-12 Sol†<br>L<br>RLA<br>—<br>—<br>Al setscrew<br>2-12<br>RLC-J<br>—<br>—<br>Al setscrew<br>2-12<br>RYA<br>—<br>—<br>Al setscrew<br>2-12||Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>HET-AW-RLC-A|
|||Cu crimp<br>6; (2) 10<br>HET-AW-RLC-B|
|||Cu crimp<br>4; (2) 8<br>HET-AW-RLC-C|
|||Cu setscrew<br>3-12 Str; 10-12 Sol<br>HET-AW-RLC-J|
|||Cu dual setscrew<br>2-12†Str; 10-12 Sol†<br>HET-AW-RYC|
|||Al setscrew<br>2-12<br>—|
|||Al dual setscrew<br>2-12†<br>—|
|||Cu crimp<br>8-16; (2) 12-16<br>—|
|||Cu crimp<br>6; (2) 10<br>HET-BW-RLC-B|
|||Cu dual setscrew<br>2-12†Str; 10-12 Sol†<br>—|
|||Cu setscrew<br>3-12 Str; 10-12 Sol<br>HET-JW-RLC-J|
|||Cu dual setscrew<br>2-12†Str; 10-12 Sol†<br>HET-JW-RYC|
|||Cu setscrew<br>3-12 Str; 10-12 Sol<br>—|
|||Cu dual setscrew<br>2-12†Str; 10-12 Sol†<br>—|
|||Al setscrew<br>2-12<br>—|
|||Cu setscrew<br>3-12<br>—|
|||Al dual setscrew<br>2-12†<br>—|
- Stranded conductors unless otherwise noted.
† Not dual wire rated. One wire per opening.
To order: specify catalog symbol HEB and the loadside terminal code plus the letter “W.” Then select a lineside terminal code that is available with the loadside terminal. Example: HEB-BW-RCL-B defines a breakaway holder with a loadside copper crimp terminal for a single #6 or two #10 wires with a lineside copper crimp terminal for a single #6 or two #10 wires.
Data sheet no. 2127
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-51
**8 — Fuse blocks and holders** ~~I~~
## Non-breakaway catalog number system HEB - A A ~~eo~~
|HEB - A A<br>~~eo~~|HEB - A A<br>~~eo~~|HEB - A A<br>~~eo~~|
|---|---|---|
|Catalog<br>symbol<br>Loadside<br>terminal<br>Lineside<br>terminal<br>Agencyinformation<br>Loadside terminal<br>UL<br>CSA<br>Terminal type<br>AWG Wire range*<br>~~eo~~||Lineside terminal<br>HET neutral<br>equivalent<br>Terminal type<br>AWG wire range*|
|HEB<br>A<br>A<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>B<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>C††<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>D††<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>J<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>K<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>R<br>—<br>—<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>L<br>—<br>—<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>W<br>—<br>—<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>Y<br>—<br>—<br>Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>B<br>A<br>X<br>X<br>Cu crimp<br>6; (2) 10<br>B<br>X<br>X<br>Cu crimp<br>6; (2) 10<br>C<br>X<br>X<br>Cu crimp<br>6; (2) 10<br>D††<br>X<br>X<br>Cu crimp<br>6; (2) 10<br>W<br>—<br>—<br>Cu crimp<br>6; (2) 10<br>C<br>C††<br>X<br>X<br>Cu crimp<br>4; (2) 8<br>D<br>D<br>X<br>X<br>Cu crimp<br>2; (2) 6<br>Z<br>A<br>—<br>—<br>Cu crimp<br>18-20<br>J<br>J<br>X<br>—<br>Cu setscrew<br>3-12 Str; 10-12 Sol<br>K<br>X<br>—<br>Cu setscrew<br>3-12 Str; 10-12 Sol<br>L<br>—<br>—<br>Cu setscrew<br>3-12 Str; 10-12 Sol<br>W<br>—<br>—<br>Cu setscrew<br>3-12 Str; 10-12 Sol<br>Y<br>—<br>—<br>Cu setscrew<br>3-12 Str; 10-12 Sol<br>L<br>L<br>—<br>—<br>Al setscrew<br>2-12<br>N<br>N<br>—<br>—<br>Al crimp<br>8 Str ;6 Sol<br>P<br>P<br>—<br>X<br>Al crimp<br>6 Str; 4 Sol<br>Q<br>Q<br>—<br>X<br>Al crimp<br>3-4 Str; 2 Sol<br>R<br>R<br>—<br>X<br>Al crimp<br>1-2 Str<br>T<br>T<br>—<br>X<br>Al crimp<br>1/0 Str<br>W<br>W<br>—<br>—<br>Cu solid<br>—||Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>HET-AA|
|||Cu crimp<br>6; (2) 10<br>HET-AB|
|||Cu crimp<br>4; (2) 8<br>—|
|||Cu crimp<br>2; (2) 6<br>—|
|||Cu setscrew<br>3-12 Str; 10-12 Sol<br>—|
|||Cu dual setscrew<br>2-12†Str; 10-12 Sol†<br>—|
|||Al crimp<br>1-2<br>—|
|||Al setscrew<br>2-12<br>—|
|||Cu solid<br>—<br>HET-AW|
|||Al dual setscrew<br>2-12†<br>—|
|||Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>—|
|||Cu crimp<br>6; (2) 10<br>HET-BB|
|||Cu crimp<br>4; (2) 8<br>—|
|||Cu crimp<br>2; (2) 6<br>—|
|||Cu solid<br>—<br>—|
|||Cu crimp<br>4; (2) 8<br>—|
|||Cu crimp<br>2; (2) 6<br>—|
|||Cu crimp<br>8-16; (2) 12-16 Str/Sol<br>—|
|||Cu setscrew<br>3-12 Str; 10-12 Sol<br>HET-JJ|
|||Cu dual setscrew<br>2-12 Str†; 10-12 Sol†<br>HET-JK|
|||Al setscrew<br>2-12<br>—|
|||Cu solid<br>—<br>—|
|||Al dual setscrew<br>2-12†<br>—|
|||Al setscrew<br>2-12<br>—|
|||Al crimp<br>8 Str; 6 Sol<br>—|
|||Al crimp<br>6 Str; 4 Sol<br>—|
|||Al crimp<br>3-4 Str; 2 Sol<br>—|
|||Al crimp<br>1-2<br>—|
|||Al crimp<br>1/0<br>—|
|||Cu solid<br>—<br>—|
- Stranded conductors unless otherwise noted.
- Not dual wire rated. One wire per opening.
To order: specify catalog symbol HEB and the loadside terminal code. Then select a lineside terminal code that is available with the loadside terminal. Example: HEB-BB defines a non-breakaway holder with a loadside copper crimp terminal for a single #6 or two #10 wires with a lineside copper crimp terminal for a single #6 or two #10 wires.
## Data sheet no. 2127
HEZ waterproof single-pole breakaway and non-breakaway Class CC in-line holder Agency information **2011/65/EU** HEZ submersible, single-pole in-line rejection • UL Listed, Guide IZLT, File E14853 fuse holders are for UL Class CC fuses. They • CSA Certified, Class 6225-01, File 47235 are available in non-breakaway and breakaway versions with terminal options to meet • RoHS compliant application needs. Breakaway versions come with insulating boots (for details, see HEB insulating • CE boot information) to provide submersibility per UL IP67. The non-breakaway version requires ordering Catalog no. Type Terminal AWG range optional insulating boots for submersibility. NonHEZ-AA Line/load Cu crimp 8-16 (2) 12-16 breakaway Ratings . ~~a~~ HEZ-AW-RLC-A Line/load Cu crimp 8-16 (2) 12-16 • Volts 600 V Line Cu crimp 8-16 (2) 12-16 Breakaway • Amps up to 30 A limited by conductor size HEZ-AW-RYC Load Cu dual 2-12 setscrew[†]
- Withstand 200 kA RMS Sym.
- Not dual wire rated, one wire per opening.
Data sheet no. 2130
Eaton.com/bussmannseries
8-52
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse blocks and holders — 8** ABST ~~an~~
## HEX (13/32" x 1-1/2" supplemental) and HEY (Class CC) dual-pole breakaway and nonbreakaway in-line holders
Breakaway and non-breakaway submersible, dual-pole in-line fuse holders available with terminal options to meet application needs. Breakaway versions come with insulating boots to provide submersibility per UL IP67. Nonbreakaway versions require ordering optional insulating boots for submersibility.
## Ratings
## Insulating boots
Two insulating boots come standard with the breakaway holder configurations. Insulating boots are not included as standard with non-breakaway holders. Two insulating boots must be ordered separately, if required, for each non-breakaway holder ordered. When insulating boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200 percent of the RMS load current.
To order insulating boots for a non-breakaway HEB holder, use these catalog numbers.
|Catalog no.|Catalog no.<br>Description|
|---|---|
|2A0660|Single conductor|
|2A0661|Dual conductor|
## Recommended crimping tools
Volts 600 V
Amps
This list is not intended to exclude the use of other crimping tools that can provide similar crimps or indents.
- Up to 30 A limited by conductor size (UL)
- Up to 15 A limited by conductor size (CSA)
## SCCR
- 200 kA RMS Sym.*
- Dependant upon fuse interrupting rating.
## Agency information
- HEX; UL Recognized, Guide IZLT2, File E14853, CSA Certified, Class 6225-01, File 47235, CE
- HEY; UL Listed, Guide IZLT, File E14853, CSA Certified, Class 6225-01, File 47235, CE
|HEB terminal<br>A|T & B P/N (Die)<br>WT-111M (C)<br>Sta-Kon ERG4002 (C)|HEB terminal<br>D|T & B P/N (Die)<br>TBM5 (Brown)<br>TBM8 (Brown)|
|---|---|---|---|
|B|WT-115A (D)||WT-115A (F)|
|C|TBM5 (Grey)|Z|WT-111M (A)|
||WT-115A (E)||Sta-Kon ERG4002 (A)|
|N, P, Q, R, T|TBM8 (Orange)|||
## HET neutral
The HET holder is a single-pole in-line holder with a permanent, solid neutral for use along with the HEB holder to provide a means of conductor continuity. The HET holder is identified by a white, plastic coupling nut. Available HET holder counterparts to their HEB equivalents are listed in the following catalog number tables. See data sheet no. 2125 for details on the HET holder.
Breakaway catalog number system
## HE_ - A W - RYC
|HE_ - A W - RYC- A W - RYCA W - RYCW - RYCRYC<br>Catalog<br>symbol<br>Loadside<br>terminal<br>Lineside<br>terminal<br>Agency Information<br>Loadside terminal<br>Lineside terminal<br>HET neutral<br>equivalent<br>UL<br>CSA<br>Terminal type<br>AWG wire range*<br>Terminal type<br>AWG wire range*<br>13/32" x 1-1/2" supplemental fuse<br>~~ToSee~~|HE_ - A W - RYC- A W - RYCA W - RYCW - RYCRYC<br>Catalog<br>symbol<br>Loadside<br>terminal<br>Lineside<br>terminal<br>Agency Information<br>Loadside terminal<br>Lineside terminal<br>HET neutral<br>equivalent<br>UL<br>CSA<br>Terminal type<br>AWG wire range*<br>Terminal type<br>AWG wire range*<br>13/32" x 1-1/2" supplemental fuse<br>~~ToSee~~|HE_ - A W - RYC- A W - RYCA W - RYCW - RYCRYC<br>Catalog<br>symbol<br>Loadside<br>terminal<br>Lineside<br>terminal<br>Agency Information<br>Loadside terminal<br>Lineside terminal<br>HET neutral<br>equivalent<br>UL<br>CSA<br>Terminal type<br>AWG wire range*<br>Terminal type<br>AWG wire range*<br>13/32" x 1-1/2" supplemental fuse<br>~~ToSee~~|HE_ - A W - RYC- A W - RYCA W - RYCW - RYCRYC<br>Catalog<br>symbol<br>Loadside<br>terminal<br>Lineside<br>terminal<br>Agency Information<br>Loadside terminal<br>Lineside terminal<br>HET neutral<br>equivalent<br>UL<br>CSA<br>Terminal type<br>AWG wire range*<br>Terminal type<br>AWG wire range*<br>13/32" x 1-1/2" supplemental fuse<br>~~ToSee~~|HE_ - A W - RYC- A W - RYCA W - RYCW - RYCRYC<br>Catalog<br>symbol<br>Loadside<br>terminal<br>Lineside<br>terminal<br>Agency Information<br>Loadside terminal<br>Lineside terminal<br>HET neutral<br>equivalent<br>UL<br>CSA<br>Terminal type<br>AWG wire range*<br>Terminal type<br>AWG wire range*<br>13/32" x 1-1/2" supplemental fuse<br>~~ToSee~~|HE_ - A W - RYC- A W - RYCA W - RYCW - RYCRYC<br>Catalog<br>symbol<br>Loadside<br>terminal<br>Lineside<br>terminal<br>Agency Information<br>Loadside terminal<br>Lineside terminal<br>HET neutral<br>equivalent<br>UL<br>CSA<br>Terminal type<br>AWG wire range*<br>Terminal type<br>AWG wire range*<br>13/32" x 1-1/2" supplemental fuse<br>~~ToSee~~|HE_ - A W - RYC- A W - RYCA W - RYCW - RYCRYC<br>Catalog<br>symbol<br>Loadside<br>terminal<br>Lineside<br>terminal<br>Agency Information<br>Loadside terminal<br>Lineside terminal<br>HET neutral<br>equivalent<br>UL<br>CSA<br>Terminal type<br>AWG wire range*<br>Terminal type<br>AWG wire range*<br>13/32" x 1-1/2" supplemental fuse<br>~~ToSee~~|HE_ - A W - RYC- A W - RYCA W - RYCW - RYCRYC<br>Catalog<br>symbol<br>Loadside<br>terminal<br>Lineside<br>terminal<br>Agency Information<br>Loadside terminal<br>Lineside terminal<br>HET neutral<br>equivalent<br>UL<br>CSA<br>Terminal type<br>AWG wire range*<br>Terminal type<br>AWG wire range*<br>13/32" x 1-1/2" supplemental fuse<br>~~ToSee~~|
|---|---|---|---|---|---|---|---|
|DRLC-A|X|X|Cu crimp|8-16; (2) 12-16|Cu crimp|8-16; (2) 12-16|HET-AW_RLC-A|
|A<br>DRLC-B|X|—|Cu crimp|8-16; (2) 12-16|Cu crimp|6; (2) 10|HET-AW_RLC-B|
|HEX<br>DRYC<br>J<br>DRYC<br>K<br>DRYC<br>Class CC rejection fuse|X<br>X<br>X|—<br>—<br>—|Cu crimp<br>Cu setscrew<br>Cu dual setscrew|8-16; (2) 12-16<br>3-12<br>2-12†|Cu dual setscrew<br>Cu dual setscrew<br>Cu dual setscrew|2-12†<br>2-12†<br>2-12†|HET-AW_RYC<br>HET-JW-RYC<br>—|
|DRLC-A|X|X|Cu crimp|8-16; (2) 12-16|Cu crimp|8-16; (2) 12-16|HET-AW_RLC-A|
|DRLC-B|X|—|Cu crimp|8-16; (2) 12-16|Cu crimp|6; (2) 10|HET-AW_RLC-B|
|HEY<br>A||||||||
|DRLC-J|X|—|Cu crimp|8-12; (2) 12-16|Cu setscrew|3-12|HET-AW_RLC-J|
|DRYC|X|—|Cu crimp|8-16; (2) 12-16|Cu dual setscrew|2-12†|HET-AW_RYC|
* Solid/stranded conductors unless otherwise noted.
† Not dual wire rated. One wire per opening.
To order: specify catalog symbol HEX and the loadside terminal code plus the letter “W.” Then select a lineside terminal code that is available with the loadside terminal. Example: HEX-AW-DRCL-B defines a breakaway holder with a loadside copper crimp terminal for a single #8-16 or two #12-16 wires with a lineside copper crimp terminal for a single #6 or two #10 wires.
Data sheet no. 2126
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
8-53
**8 — Fuse blocks and holders**
Non-breakaway catalog number system
## HE_ - A A
|Catalog<br>symbol|Loadside<br>terminal<br>Lineside<br>terminal|Loadside<br>terminal<br>Lineside<br>terminal|Agency information<br>Loadside terminal<br>Lineside terminal<br>HET neutral<br>equivalent<br>UL<br>CSA<br>Terminal type<br>AWG Wire range*<br>Terminal type<br>AWG wire range*|
|---|---|---|---|
|13/32" x|1-1/2" supplemental fuse|||
|HEX|A|A<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>8-16; (2) 12-16<br>HET-AA||
|||B<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>6; (2) 10<br>HET-AB||
|||C<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>4 str; (2) 8<br>—||
|||D<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>2 str; (2) 6<br>—||
|||E<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>(2) 4<br>—||
||B|B<br>X<br>X<br>Cu crimp<br>6; (2) 10<br>Cu crimp<br>6; (2) 10<br>HET-BB||
||C|C<br>X<br>X<br>Cu crimp<br>4 str; (2) 8<br>Cu crimp<br>4 str; (2) 8<br>—||
||J|J<br>X<br>—<br>Cu setscrew<br>3-12<br>Cu setscrew<br>3-12<br>HET-JJ||
|||K<br>X<br>—<br>Cu setscrew<br>3-12<br>Cu dual setscrew<br>2-12†<br>HET-JK||
|Class CC rejection||fuse||
|HEY|A|A<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>8-16; (2) 12-16<br>HET-AA||
|||B<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>6; (2) 10<br>HET-AB||
|||C<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>4 str; (2) 8<br>—||
|||D<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>2 str; (2) 6<br>—||
|||E<br>X<br>X<br>Cu crimp<br>8-16; (2) 12-16<br>Cu crimp<br>(2) 4<br>—||
||B|B<br>X<br>X<br>Cu crimp<br>6; (2) 10<br>Cu crimp<br>6; (2) 10<br>HET-BB||
||J|J<br>X<br>—<br>Cu setscrew<br>3-12<br>Cu setscrew<br>3-12<br>HET-JJ||
- Solid/stranded conductors unless otherwise noted.
† Not dual wire rated. One wire per opening.
To order: specify catalog symbol HE_ and the loadside terminal code. Then select a lineside terminal code that is available with the loadside terminal. Example: HEX-BB defines a non-breakaway holder with a loadside copper crimp terminal for a single #6 or two #10 wires with a lineside copper crimp terminal for a single #6 or two #10 wires.
Data sheet no. 2126
Eaton.com/bussmannseries
8-54
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Power distribution and terminal blocks — 9**
## Contents
|||||Description|Section<br>page|
|---|---|---|---|---|---|
|||||Selecting power distribution blocks|2|
|Maximize short-circuit current<br>rating up to 200 kA||Maximize short-circuit current||Power distribution blocks<br>PDBFS UL Listed finger-safe, high SCCR blocks<br>PDB UL Listed high SCCR open blocks<br>160, 162, 163, 164 and 165 UL Recognized open blocks|3-5<br>6-8<br>9-12|
|||||Power stud terminal blocks||
|||||162, 163 and 165 UL Recognized blocks|13-14|
|||||Power splicer blocks||
|||||160, 162, 163 and 165 UL Recognized blocks|15-16|
|||||Power terminal blocks||
|roe |"|||||11675 250 V screw/quick-connect block<br>17<br>11725 600 V screw/quick-connect block<br>Barrier and deadfront terminal blocks<br> ~~ce~~||
|114HEX|i1|iy|14002 600 V barrier block<br>17<br>14004 600 V dead front block<br>~~TTT~~|||
Maximize short-circuit current rating up to 200 kA
Simplify your panel design
To save panel space and reduce component count, Bussmann series power distribution fuse blocks combine circuit protection and power distribution into one unit. Available in Class H(K), and R up to 60 amps and Class J up to 400 amps, with up to a high 200 kA withstand rating. See these cost and space saving products in Section 8, Fuse blocks and holders.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
9-1
**9 — Power distribution and terminal blocks**
## Selecting SCCR power distribution blocks and terminal blocks
## Short-circuit current rated power distribution blocks
Bussmann series power distribution blocks have three distinct styles to match different application needs. There are the PDBFS_ and PDB_ high short-circuit current rated power distribution blocks and the 16_ power terminal blocks. The differences are whether the power distribution blocks are enclosed or not, and whether they are UL 1953 Listed power distribution blocks or UL 1059 Recognized power terminal blocks, which have different minimum spacing requirements. The table on this page will assist you in selecting which block is right for your application.
## Why these are important
Power distribution and terminal blocks not marked with a component SCCR are typically one of the weakest links in a control panel's equipment SCCR and may limit the equipment SCCR to no more than 10 kA. The PDBFS_ and PDB_ products have the increased spacing required for use in feeder circuits of equipment listed to UL 508A (UL 1059 terminal blocks must be evaluated for proper spacings). Also, for building wiring systems, the PDBFS_ and PDB_ power distribution blocks can be used to meet the 2014 NEC requirements in section 376.56(B) for power distribution blocks in wireways.
## Selection table
Per the NEC and OSHA, equipment cannot be installed in an electrical system at a location where the available fault (short-circuit) current is greater than the equipment's SCCR.
Further, equipment SCCRs are required in the 2014 NEC and for UL 508A Listed control panels. Marking the equipment SCCR on control panels (NEC 409.110), industrial machinery electrical panels (NEC 670.3(A)), and HVAC equipment (NEC 440.4(B)) is required by the NEC.
The table below provides an overview of the three Bussmann series power distribution and terminal blocks mentioned above. For details on the PDB_ blocks, see data sheet number 10537. For the 16_ blocks, see data sheet numbers 10533 (UL Recognized power distribution blocks), 10534 (splicer blocks) and 10535 (stud blocks).
**==> picture [537 x 35] intentionally omitted <==**
**----- Start of picture text -----**<br>
Wireways NEC<br>Catalog High Spacing ** 1” UL 508A panel UL 508A panel HVAC UL 376.56(B) (requires<br>symbol UL status Enclosed SCCR* air, 2” surface branch circuit feeder circuit 1995 UL 1953)<br>**----- End of picture text -----**<br>
|Catalog<br>symbol|UL status|Enclosed|High<br>SCCR*|Spacing ** 1”<br>air, 2” surface|UL 508A panel<br>branch circuit|UL 508A panel<br>feeder circuit|HVAC UL<br>1995|Wireways NEC<br>376.56(B) (requires<br>UL 1953)|
|---|---|---|---|---|---|---|---|---|
||UL 1953||||||||
|PDBFS_|Listed power<br>distribution|Yes***|Yes|Yes|Yes|Yes|Yes|Yes|
||blocks||||||||
||UL 1953||||||||
|PDB_|Listed power<br>distribution|No†|Yes|Yes|Yes|Yes|Yes|Yes, with optional<br>cover|
||blocks||||||||
||UL 1059||||||||
|16_|Recognized<br>terminal|No†|Yes|No††|Yes|No††|Yes|No|
||blocks||||||||
* When protected by proper fuse class with maximum ampere rating specified or smaller.
** For details, see PDB and TB minimum spacing requirements for equipment table below.
- *** IP20 finger-safe under specific conditions, see data sheet 10536.
- Optional covers are available. Not IP20, but provide a safety benefit.
†† No, except if single pole units installed with proper spacings.
Power distribution and terminal block minimum spacing requirements for equipment
|UL standard|Spacing between live parts of opposite polarity<br>Spacing between live parts and<br>grounded parts or enclosure @ 600 V<br>Through air @ 600 V<br>Over surface @ 600 V|
|---|---|
|508A feeder circuits|1"<br>2"<br>1"|
|508A branch circuits|3/8"<br>1/2"<br>1/2"|
|1995 HVAC|3/8"<br>1/2"<br>1/2"|
Note: Refer to specific UL standards for complete spacing details.
Eaton.com/bussmannseries
9-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Power distribution and terminal blocks — 9**
## PDBFS UL Listed finger-safe, high SCCR power distribution blocks
These single pole, small footprint, high Short-Circuit Current Rating (SCCR) power distribution blocks provide IP20* fingersafe protection in a modular design that permits dovetailing together the required number of poles and still meet the UL 1953 minimum 1" and 2" spacing required per UL 508A for feeder circuit applications and per NEC for field installations.
With SCCRs up to 200 kA, these blocks help achieve compliance with NEC and OSHA requirements by resolving a common SCCR "weak link" in industrial control panels.
To increase application flexibility, these blocks feature dual-wire rated ports that accept copper or aluminum conductors while retaining a UL Listed status.
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
With panel or 35mm DIN-Rail** mounting these blocks are suitable for installation in wireways and industrial control panel feeder and branch circuits.
Catalog number example — PDBFS204 is a 1-pole block
Where:
- The catalog symbol "PDBFS" defines the block as a finger-safe design
- The catalog number ending "204" in this example defines this block's lineside and loadside characteristics covering the amp rating, number of ports and wire sizes, etc.
- See the catalog number table for details on the available lineside/loadside characteristics.
## Features
- IP20 finger-safe under specified conditions increases safety by isolating energized connections
- Wire-ready captive termination screws cannot be misplaced and are shipped "backed out" to save time on conductor installation
- Sliding DIN-Rail latch provides easy block mounting
- For multiple pole applications, all single-pole units can be gang mounted by using the interlocking dovetail pins that are preinstalled on the side of the blocks
- Elongated panel-mounting holes provide greater flexibility and installation ease when matching up with drilled panel holes
- See table on page 9-5.
- ** PDFFS504 panel mount only.
## Ratings
- Volts
- 600 V (UL)
- 690 V (IEC)
- 1000 V (self-certified)
- Amps 175 to 760 A
- SCCR Up to 200 kA (see table for circuit protection details)
## Conductors[†]
- Stranded 75°C copper and aluminum
- Higher temperature rated conductors permitted with appropriate derating
- As specified in the catalog number table.
## Agency information
## Dual wire port application
- Rated for dual wire port application to increase the possible number of lineside and loadside connections. E.g., PDBFS220 can accept two wires into the lineside port (4 - 14 Cu, 4 - 8 Al) and two wires per port (eight connections total) on the loadside lug (8 - 14 Cu, 8 Al).
- Dual wire applications are only viable when using two wires of the same size, stranding, and insulating and conductor material.
- Ferrule terminal application
- Bussmann series PDBFS power distribution blocks are rated for use with UL Listed ferrules (see catalog number table for details).
- Ferrule applications allow for the use of a broader range of conductor stranding and simulate a more efficient, solid wire connection with the PDBFS terminal port.
- Always use UL Listed ferrules in accordance with the manufacturer's specifications and instructions.
Multi-pole block ganging
- UL 1953 Listed, Guide QPQS, File E256146
- CSA Certified, Class 6228-01, File 47235
- RoHS compliant
- CE
## Flammability rating
Dovetail feature permits easy ganging for multi-pole applications
- UL 94 V0
## How to order
- From the catalog number table, select the catalog number that defines the desired lineside/loadside port and conductor characteristics
- Order one block per pole for the application
- Multiple single-pole blocks can be ganged together via the dovetailing feature to form multi-pole configurations
PDBFS blocks can be ganged for the required number of poles.
To gang two or more blocks for DIN-Rail or panel mounting, place them side-by-side and slide the dovetail pin of one block into the reciprocal slot on the other until fully seated and both blocks are coplanar.
Note: Dissimilar PDBFS blocks can be ganged. E.g., a PDBFS204 can be ganged with a PDBFS220. Ganging with a PDBFS504 (nonDIN Rail mount version) will prevent DIN-Rail mounting.
Data sheet no. 10536
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
9-3
## **9 — Power distribution and terminal blocks**
**==> picture [537 x 355] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lineside Loadside<br>Current Wire size Wires Wire size Wires Max<br>Line/load port rating (Str/ferrule unless per Torque Ports/ (Str/ferrule unless per Torque Ports/ SCCR Catalog<br>configuration (A) noted)* port N•m (lb-in) pole noted)* port N•m (lb-in) pole (kA)** no.<br>2/0 - 1 Cu/Al (Str) 1 2/0 - 1 Cu/Al (Str) 1<br>2 - 3 Cu/Al 1 12.4 (110) [††] 2 - 3 Cu/Al 1 12.4 (110) [††]<br>4 - 8 Cu/Al 1 4 - 8 Cu/Al 1<br>175 10 - 12 Al (Str) 1 1 10 - 12 Al (Str) 1 1 200 PDBFS204<br>4.0 (35) 4.0 (35)<br>10 - 14 Cu 1 10 - 14 Cu 1<br>4 - 8 Cu/Al 2 4 - 8 Cu/Al 2<br>13.6 (120) 13.6 (120)<br>10 - 14 Cu 2 10 - 14 Cu 2<br>2/0 - 1 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>2 - 3 Cu/Al 1 8 Cu 1<br>175 13.6 (120) 1 2.8 (25) 4 200 PDBFS220<br>4 - 8 Cu/Al 1-2 8 Al (Str) 1-2<br>10 - 14 Cu 1-2 10 - 14 Cu 1-2 2.3 (20)<br>350kcmil - 2/0 Cu/Al (Str) 1 350kcmil - 2/0 Cu/Al (Str) 1<br>310 1/0 Cu/Al (Str) 1-2 31.1 (275) [†] 1 1/0 Cu/Al (Str) 1-2 31.1 (275) [†] 1 200 PDBFS303<br>1 - 6 Cu/Al 1-2 1 - 6 Cu/Al 1-2<br>2 - 3 Cu/Al (Str) 1 5.6 (50)<br>500kcmil - 4/0 Cu/Al (Str) 1<br>4 Cu/Al 1<br>5.1 (45)<br>380 3/0 - 1/0 Cu/Al (Str) 1-2 56.5 (500) 1 6 Cu/Al 1-2 6 200 PDBFS330<br>8 Cu/Al 1-2 4.5 (40)<br>1 - 6 Cu/Al 1-2<br>10 - 14 Cu 1-2 4.0 (35)<br>300kcmil - 2/0 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>1/0 Cu/Al (Str) 1-2 8 Cu 1<br>2.8 (25)<br>570 1 - 2 Cu/Al 1-2 31.1 (275) [†] 2 8 Al (Str) 1-2 12 200 PDBFS377<br>10 - 12 Al (Str) 1<br>4 Cu/Al (Str) 1-2 2.3 (20)<br>10 - 14 Cu 1-2<br>350kcmil - 2/0 Cu/Al (Str) 1 350kcmil - 2/0 Cu/Al (Str) 1<br>1/0 Cu/Al (Str) 1-2 1/0 Cu/Al (Str) 1-2<br>620 31.1 (275) [†] 2 31.1 (275) [†] 2 200 PDBFS500<br>1 - 4 Cu/Al 1-2 1 - 4 Cu/Al 1-2<br>6 Cu/Al 2 6 Cu/Al 2<br>500kcmil - 4/0 Cu/Al (Str) 1 500kcmil - 4/0 Cu/Al (Str) 1<br>760 3/0 - 1/0 Cu/Al (Str) 1-2 56.5 (500) 2 3/0 - 1/0 Cu/Al (Str) 1-2 56.5 (500) 2 200 PDBFS504<br>1 - 6 Cu/Al 1-2 1 - 6 Cu/Al 1-2<br>**----- End of picture text -----**<br>
- 75°C wire (higher temperature rated wire acceptable with appropriate derating). Using a ferrule on a stranded conductor requires a correctly sized UL Listed ferrule (customer supplied) applied according to the manufacturer’s specifications. Ferrule ratings apply to copper wire only.
- ** See pages 9-4 and 9-5 for the tested upstream overcurrent protective devices necessary for achieving these SCCRs.
- Torque rating for dual wire and ferrule application is 30.5 N•m (270 lb-in).
- †† Torque rating for ferrule application is 13.6 N•m (120 lb-in).
## Upstream fusing for SCCR and minimum enclosure data
This table contains the tested SCCR levels for each PDBFS power distribution block using the specified lineside and loadside conductors and Bussmann series Class J, RK1, RK5 and T fuses. Using these tested SCCR levels also requires the power distribution block be installed in an enclosure with the minimum size indicated for each catalog number.
**==> picture [537 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
Conductors (AWG/kcmil) Fuse class and maximum amps*<br>RK1 — LPN-RK (250 V) RK5 — FRN-R (250 V), T — JJN (300 V), Min. enclosure<br>Catalog no. Lineside Loadside J — LPJ LPS-RK (600 V) FRS-R (600 V) JJS (600 V) SCCR (kA) size (in)<br>**----- End of picture text -----**<br>
|PDBFS204|2/0 - 8|2/0 - 8|200<br>100<br>60<br>200<br>200<br>16 x 16 x 6.75|
|---|---|---|---|
|PDBFS220|2/0 - 8|4 - 12<br>4 - 14|200<br>100<br>60<br>200<br>200<br>16 x 16 x 6.75<br>175<br>100<br>30<br>175<br>100<br>200<br>100<br>60<br>200<br>50|
|PDBFS303|350 - 6|350 - 6|400<br>200<br>100<br>400<br>200<br>36 x 30 x 12.625|
|PDBFS330|500 - 6|2 - 6<br>6 - 14|400<br>200<br>100<br>400<br>200<br>24 x 20 x 6.75<br>200<br>100<br>60<br>200<br>50<br>175<br>100<br>30<br>175<br>100|
|PDBFS377|300 - 4<br>4|4<br>4 - 14|600<br>400<br>200<br>600<br>200<br>24 x 20 x 6.75<br>400<br>200<br>100<br>400<br>100<br>200<br>100<br>60<br>200<br>50<br>600<br>400<br>200<br>600<br>50|
|||4||
|PDBFS500|350<br>350 - 4|350|600<br>400<br>200<br>600<br>200<br>36 x 30 x 12.625<br>600<br>400<br>200<br>600<br>100|
|||350 - 4||
|PDBFS504|500<br>500 - 6|500|600<br>600<br>200<br>800**<br>200<br>36 x 30 x 12.625<br>600<br>400<br>200<br>600<br>100|
|||500 - 6||
Ampacities 75°C per NEC[®] Table 310.16 and UL 508A Table 28.1.
- Class G 60 A (SC-60) or less or Class CC 30 A (LP-CC-30, FNQ-R-30, KTK-R-30) or less are suitable for all SCCRs in this table.
- ** Class L 800 A (KRP-C 800_SP) or less fuses suitable for this particular SCCR case.
Data sheet no. 10536
Eaton.com/bussmannseries
9-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Power distribution and terminal blocks — 9**
## Upstream circuit breakers for SCCR and minimum enclosure data
This table contains the tested SCCR levels for each PDBFS power distribution block using the specified lineside and loadside conductors and Eaton and General Electric circuit breakers. Using these tested SCCR levels also requires the power distribution block be installed in an enclosure with the minimum size indicated for each catalog number.
## PDBFS SCCR as rated with Eaton circuit breakers
**==> picture [537 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
Suitable Cu conductors kcmil/AWG SCCR, RMS Overcurrent protection circuit breaker required Min. enclosure size<br>Catalog no. Lineside Loadside Sym. (kA) Volts max Type Max amp (in.)<br>**----- End of picture text -----**<br>
|PDBFS204<br>2/0 - 8|2/0 - 8|65<br>480|EGC125,E125C,EGH125,E125H<br>125<br>16 x 16 x 6.75|
|---|---|---|---|
|PDBFS330<br>500 - 3|2 - 8|14<br>480<br>25|LGH400, L400H, LGE400, L400E,<br>LGS400,L400S<br>400<br>24 x 20 x 6.75<br>LGC400, L400C, LGU400, L400U,<br>LGX400,L400X|
|PDBFS377<br>(2) 300 - 2|4|30<br>480<br>18<br>14<br>42<br>35<br>14|LGH600, L600H, LGE600, L600E,<br>LGS600, L600S<br>600<br>24 x 20 x 6.75<br>LGC600, L600C, LGU600, L600U,<br>LGX600, L600X|
||6|||
||8|||
||4|||
||6|||
||8|||
## PDBFS SCCR as rated with General Electric circuit breakers
**==> picture [537 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
Suitable Cu conductors kcmil/AWG SCCR, RMS Overcurrent protection circuit breaker required Min. enclosure size<br>Catalog no. Lineside Loadside Sym. (kA) Volts max Type Max amp (in.)<br>65 SELA 150<br>PDBFS204 2/0 - 8 2/0 - 8 480 16 x 16 x 6.75<br>25 SEHA 150<br>**----- End of picture text -----**<br>
|Catalogno.<br>PDBFS204|Suitable Cu co<br>Lineside<br>2/0 - 8|nductors kcmil/AWG<br>Loadside<br>2/0 - 8|SCCR, RMS<br>Sym.(kA)<br>Volts max<br>65<br>480<br>25|Overcurrentprotection circuit breaker required<br>Min. enclosure size<br>(in.)<br>Type<br>Max amp<br>SELA<br>150<br>16 x 16 x 6.75<br>SEHA<br>150|
|---|---|---|---|---|
|PDBFS220|2/0 - 8|4 - 12|65<br>480<br>25|SELA<br>150<br>16 x 16 x 6.75<br>SEHA<br>150|
|PDBFS303|250 - 6<br>3/0 - 6|350 - 6|65<br>480<br>35<br>65<br>25|SFLA<br>250<br>24 x 20 x 6.75<br>SFHA<br>250<br>SELA<br>150<br>SEHA<br>150|
|||250 - 6|||
|||350 - 6|||
|PDBFS330|250 - 6<br>3/0 - 6|2 - 12|65<br>480<br>35<br>65<br>25|SFLA<br>250<br>24 x 20 x 6.75<br>SFHA<br>250<br>SELA<br>150<br>SEHA<br>150|
## Specified installation conditions for IP20 finger-safe ratings
This table contains the installed wire and trim lengths, and other conditions the PDBFS power distribution blocks need in order to be compliant with IP20 specifications. IP20 compliance status is indicated in the lineside and loadside wire port and terminal screw opening columns.
**==> picture [562 x 55] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lineside Loadside<br>IP20 status IP20 status<br>Terminal Terminal<br>Wire trim length - Wire port screw Wire trim length - Wire port screw<br>Catalog no. Installed wire/state in (mm) opening opening Installed wire/state in (mm) opening opening<br>PDBFS204 2/0 - 8 0.85 (22) Yes Yes 2/0 - 8 0.97 (25) Yes Yes<br>**----- End of picture text -----**<br>
|Catalogno.<br>Lineside<br>Installed wire/state<br>Wire trim length -<br>in(mm)<br>IP20 status<br>Wire port<br>opening<br>Terminal<br>screw<br>opening|Catalogno.<br>Lineside<br>Installed wire/state<br>Wire trim length -<br>in(mm)<br>IP20 status<br>Wire port<br>opening<br>Terminal<br>screw<br>opening|Catalogno.<br>Lineside<br>Installed wire/state<br>Wire trim length -<br>in(mm)<br>IP20 status<br>Wire port<br>opening<br>Terminal<br>screw<br>opening|Loadside|Loadside|Loadside|
|---|---|---|---|---|---|
||||Installed wire/state<br>Wire trim length -<br>in(mm)<br>IP20 status<br>Wire port<br>opening<br>Terminal<br>screw<br>opening|||
|PDBFS204<br>2/0 - 8<br>0.85(22)<br>Yes<br>Yes|||2/0 - 8<br>0.97(25)<br>Yes<br>Yes|||
|PDBFS220|2/0 - 8<br>0.75 (19)|Yes<br>Yes|4 - 14<br>Top row 0.55 (14),<br>Bottom row 0.85 (22)<br>Screws fullyopened<br>No wire in hole|Yes<br>Yes||
|||||N/A<br>Yes||
|||||No<br>N/A||
|PDBFS303|350kcmil - 2/0<br>1.35 (34)<br>1/0 - 6|Yes<br>Yes|350kcmil - 2/0<br>1.25 (32)<br>1/0 - 6|Yes<br>Yes||
|||No<br>Yes||No<br>Yes||
|PDBFS330|500 - 250kcmil<br>1.25 (32)<br>4/0 - 6|Yes<br>Yes|2 - 14<br>Top row 0.59 (15),<br>Bottom row 1.2 (30)<br>Screws fullyopened<br>No wire in hole|Yes<br>Yes||
|||No<br>Yes||N/A<br>Yes||
|||||Yes<br>N/A||
|PDBFS377|300kcmil - 4/0<br>Top row 1.15 (29)<br>bottom row 1.4 (36)<br>3/0 - 4<br>Screws fullyopen<br>No wire inport|Yes<br>Yes|4 - 14<br>Top row 0.55 (14),<br>Middle row 1.00 (35),<br>Bottom row 1.22 (31)<br>Screws fullyopen<br>No wire in port|Yes<br>Yes||
|||No<br>Yes||N/A<br>Yes||
|||N/A<br>No||Yes<br>N/A||
|||No<br>N/A||||
|PDBFS500|350kcmil - 2/0<br>1.25 (32)<br>1/0 - 4<br>Screws fullyopened<br>No wire inport|No<br>Yes|350kcmil - 2/0<br>1.25 (32)<br>1/0 - 4<br>Screws fullyopen<br>No wire inport|Yes<br>Yes||
|||No<br>Yes||No<br>Yes||
|||N/A<br>No||N/A<br>No||
|||No<br>N/A||No<br>N/A||
|PDBFS504|500 - 350kcmil<br>1.25 (32)<br>300 - 6<br>Screws fullyopen<br>No wire inport|Yes<br>Yes|500 - 350kcmil<br>1.25 (32)<br>300 - 6<br>Screws fullyopened<br>No wire inport|Yes<br>Yes||
|||No<br>Yes||No<br>Yes||
|||N/A<br>No||N/A<br>No||
|||No<br>N/A||No<br>N/A||
|||||||
Data sheet no. 10536
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
9-5
**9 — Power distribution and terminal blocks**
## PDB UL Listed high SCCR open power distribution blocks
High Short-Circuit Current Rating (SCCR) power distribution blocks provide up to 200 kA SCCR and help achieve compliance with NEC and OSHA requirements by resolving a common SCCR “weak link” in industrial control panels.
Available in 1-, 2- and 3-pole panel mount versions with popular lineside and loadside port configurations, these blocks are UL Listed with the requisite spacing between uninsulated opposite polarities or ground by meeting the UL 1953 1” through air and 2” over surface spacings required per UL 508A for feeder circuit applications and per NEC for field installations.
To increase application flexibility, these blocks feature dual-wire rated ports that accept copper or aluminum conductors while retaining a UL Listed status.
Optional covers are available to enhance electrical safety.
## Ratings
- Volts 600 V
- Amps 175 to 310 A
- SCCR 200 kA (see table for circuit protection details)
## Conductors[†]
- Stranded 75°C copper and aluminum
- Higher temperature rated conductors permitted with appropriate derating
- As specified in the catalog number table.
## Agency information
## Features
- High SCCRs up to 200 kA, assist in achieving high SCCR for a control panel per NEC and UL 508A requirements
- In compliance with UL 1953 minimum spacing requirements for industrial control panel feeder and branch circuits
- Optional covers available to reduce the risk of accidental contact with energized components
## Dual wire port application
- Rated for dual wire port application to increase the possible number of lineside and loadside connections. E.g., PDB220 can accept two wires into the lineside port (4-14 Cu, 4-8 Al) and two wires per port (eight connections per pole total) on the loadside lug (8-14 Cu, 8 Al).
- Dual wire applications are only viable when using two wires of the same size, stranding, and insulating and conductor material in the same port
## Ferrule terminal application
- Bussmann series PDB power distribution blocks are rated for use with UL Listed ferrules (see catalog number table for details)
- Ferrule applications allow for the use of a broader range of conductor stranding and simulate a more efficient, solid wire connection with the PDB terminal port
- Always use UL Listed ferrules in accordance with the manufacturer’s specifications and instructions
## Optional covers
Electrical safety can be enhanced by installing optional covers.
From the table below, order the cover catalog number that matches the block catalog number. Order the quantity indicated in the “order quantity” column. E.g., the 3-pole block PDB204-3 requires ordering three CPB162-1 covers (one cover for each pole).
- UL 1953 Listed, Guide QPQS, File E256146
- CSA Certified, Class 6228-01, File 47235
- CE
## Flammability rating
- UL 94 V0
## How to order
From the catalog number table, select the catalog number that defines the desired lineside/loadside port and conductor characteristics.
Add to the catalog number the suffix that defines the desired pole configuration. Note, you must select from the available number of poles for each catalog number. These appear in the second column of the catalog number tables.
## Catalog number example — PDB323-3 is a 3-pole PDB323
## Where:
|Block catalogno.|Poles|Cover catalogno.|Orderquantity|
|---|---|---|---|
|PDB204-1|1|CPB162-1|1|
|PDB204-3|3|CPB162-1|3|
|PDB220-1|1|CPB162-1|1|
|PDB220-3|3|CPB162-1|3|
|PDB280-1|1|CPB162-1|1|
|PDB280-3|3|CPB162-1|3|
|PDB323-1|1|CPDB-1|1|
|PDB323-3|3|CPDB-1|3|
|PDB370-1|1|CPDB-1|1|
|PDB370-3|3|CPDB-1|3|
|PDB371-1<br>PDB371-3|1<br>3|CPDB-1<br>CPDB-1|1<br>3|
|PDB321-1|1|CPDB-1*|1|
|PDB321-2|2|CPDB-2*|1|
|PDB321-3|3|CPDB-3*|1|
* For the PDB321-_ blocks, order one cover for each block (not per pole).
- The prefix “PDB323” defines the block’s lineside characteristics (i.e., one conductor port per pole that accepts 350kcmil-6 Cu/Al conductors) and the loadside characteristics (i.e., six (6) conductor ports per pole that each accepts 4-14 Cu or 4-12 Al conductors)
- The suffix “3” in this example defines this as a three-pole block
- See the catalog number table for details on the available lineside/ loadside characteristics
## Data sheet no. 10537
Eaton.com/bussmannseries
9-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Power distribution and terminal blocks — 9**
**==> picture [537 x 461] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lineside Loadside<br>Current Wire size Wires Wire size Wires Max<br>Line/load port No. of rating (Str/ferrule unless per Torque Ports/ (Str/ferrule unless per Torque Ports/ SCCR Catalog<br>configuration poles (A) noted)* port N•m (lb-in) pole noted)* port N•m (lb-in) pole (kA)** no.<br>2/0 - 1 Cu/Al (Str) 1 2/0 - 1 Cu/Al (Str) 1<br>2 - 3 Cu/Al 1 12.4 (110) [††] 2 - 3 Cu/Al 1 12.4 (110) [††]<br>4 - 8 Cu/Al 1 4 - 8 Cu/Al 1<br>1, 3 175 10 - 12 Al (Str) 1 1 10 - 12 Al (Str) 1 1 200 PDB204-_<br>4.0 (35) 4.0 (35)<br>10 - 14 Cu 1 10 - 14 Cu 1<br>4 - 8 Cu/Al 2 4 - 8 Cu/Al 2<br>13.6 (120) 13.6 (120)<br>10 - 14 Cu 2 10 - 14 Cu 2<br>2/0 - 1 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>2 - 3 Cu/Al 1 8 Cu 1<br>1, 3 175 13.6 (120) 1 2.8 (25) 4 200 PDB220-_<br>4 - 8 Cu/Al 1-2 8 Al (Str) 1-2<br>10 - 14 Cu 1-2 10 - 14 Cu 1-2 2.3 (20)<br>2/0 - 1 Cu/Al (Str) 1<br>1, 3 175 2 - 3 Cu/Al 1 13.6 (120) 1 1/4-20 x 3/4” Stud — — 1 200 PDB280-_<br>4 - 8 Cu/Al 1-2<br>10 - 14 Cu 1-2<br>2/0 - 1 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1<br>4.0 (35)<br>2 - 3 Cu/Al 1 8 Al (Str) 1-2<br>1, 2, 3 175 4 - 8 Cu/Al 1-2 13.6 (120) 1 8 Cu 1 2.8 (25) 6 200 PDB321-_<br>10 - 12 Al (Str) 1 10 - 12 Al (Str) 1 4.0 (35)<br>10 - 14 Cu 1-2 10 - 14 Cu 1-2 2.3 (20)<br>4 - 6 Cu/Al (Str) 1<br>350kcmil - 2/0 Cu/Al (Str) 1 4.0 (35)<br>8 Al (Str) 1-2<br>1/0 Cu/Al (Str) 1-2 8 Cu 1 2.8 (25)<br>1, 3 310 31.1 (275) [†] 1 6 200 PDB323-_<br>10 - 12 Al (Str) 1 4.0 (35)<br>1 - 6 Cu/Al 1-2 10 - 12 Cu 1<br>2.3 (20)<br>10 - 14 Cu 2<br>350kcmil - 2/0 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1<br>4.0 (35)<br>8 Al (Str) 1-2<br>1/0 Cu/Al (Str) 1-2<br>1, 3 310 31.1 (275) [†] 1 8 Cu 1 2.8 (25) 12 200 PDB370-_<br>10 - 12 Al (Str) 1 4.0 (35)<br>1 - 6 Cu/Al 1-2<br>10 - 14 Cu 1-2 2.3 (20)<br>2 - 3 Cu/Al (Str) 1<br>4 - 8 Al (Str) 1 5.6 (50)<br>350kcmil - 2/0 Cu/Al (Str) 1 6 - 8 Al (Str) 2<br>4 Cu 1<br>5.1 (45) 6<br>6 Cu 1-2<br>8 Cu 1-2 4.5 (40)<br>10 - 12 Cu 1-2<br>1, 3 310 31.1 (275) [†] 1 4.0 (35) 200 PDB371-_<br>1/0 Cu/Al (Str) 1-2 14 Cu 2<br>1/0 - 3 Cu/Al (Str) 1 5.6 (50)<br>4 - 6 Cu/Al 1 5.1 (45) [††]<br>8 Cu/Al 1 4.5 (40) [††]<br>3<br>10 - 12 Cu 1 4.0 (35) [††]<br>1 - 6 Cu/Al 1-2<br>6 - 14 Cu 2<br>13.6 (120)<br>4 - 6 Al (Str) 2<br>**----- End of picture text -----**<br>
- 75°C wire (higher temperature rated wire acceptable with appropriate derating). Using a ferrule on a stranded conductor requires a correctly sized UL Listed ferrule (customer supplied) applied according to the manufacturer’s specifications. Ferrule ratings apply to copper wire only.
- ** See page 9-8 for the tested upstream overcurrent protective devices necessary for achieving these SCCRs.
- Torque rating for dual wire and ferrule application is 30.5 N•m (270 lb-in).
- †† Torque rating for ferrule application is 13.6 N•m (120 lb-in).
Data sheet no. 10537
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
9-7
## **9 — Power distribution and terminal blocks**
Upstream fusing for SCCR and minimum enclosure data
This table contains the tested SCCR levels for each PDBFS power distribution block using the specified lineside and loadside conductors and Bussmann series Class J, RK1, RK5 and T fuses. Using these tested SCCR levels also requires the power distribution block be installed in an enclosure with the minimum size indicated for each catalog number.
**==> picture [539 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
Conductors (AWG/kcmil) Fuse class and maximum amps*<br>RK1 — LPN-RK (250 RK5 — FRN-R (250 V), T — JJN (300 SCCR Min. enclosure<br>Catalog no. Lineside Loadside G — SC (480 V) J — LPJ V), LPS-RK (600 V) FRS-R (600 V) V), JJS (600 V) (kA) size (in)<br>**----- End of picture text -----**<br>
|PDB204-1, -3<br>2/0 - 8|2/0 - 8<br>—<br>200<br>100<br>60<br>200<br>200<br>16 x 16 x 6.75|
|---|---|
|PDB220-1, -3<br>2/0 - 8|4 - 12<br>—<br>200<br>100<br>60<br>200<br>200<br>16 x 16 x 6.75<br>4 - 14<br>60<br>175<br>100<br>30<br>175<br>100|
|PDB280-1, -3<br>2/0 - 8|Stud<br>—<br>200<br>100<br>60<br>200<br>200<br>16 x 16 x 6.75|
|PDB321-1, -2, -3<br>2/0 - 8|4 - 12<br>—<br>400<br>200<br>100<br>400<br>200<br>24 x 20 x 6.75<br>4 - 14<br>60<br>175<br>100<br>30<br>175<br>100|
|PDB323-1, -3<br>350 - 4|4 - 8<br>—<br>400<br>200<br>100<br>400<br>200<br>24 x 20 x 6.75<br>4 - 12<br>60<br>175<br>100<br>30<br>175<br>100|
|PDB370-1, -3<br>350 - 4|4 - 8<br>—<br>400<br>200<br>100<br>400<br>200<br>24 x 20 x 6.75<br>4 - 14<br>60<br>175<br>100<br>30<br>175<br>100|
|PDB371-1, -3<br>350 - 4|1/0 - 6<br>—<br>400<br>200<br>100<br>400<br>200<br>24 x 20 x 6.75<br>1/0 - 12<br>60<br>175<br>100<br>30<br>175<br>100|
Ampacities 75°C per NEC Table 310.16 and UL 508A Table 28.1. * Class CC 30 A (LP-CC-30, FNQ-R-30, KTK-R-30) or less are suitable for all SCCRs in this table.
## Upstream circuit breakers for SCCR and minimum enclosure data
This table contains the tested SCCR levels for each PDB power distribution block using the specified lineside and loadside conductors and Eaton circuit breakers. Using these tested SCCR levels also requires the power distribution block be installed in an enclosure with the minimum size indicated for each catalog number.
PDB_ SCCR as rated with Eaton circuit breakers
**==> picture [536 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
Suitable Cu conductors kcmil/AWG Overcurrent protection circuit breaker required Min.<br>SCCR, RMS Volts enclosure<br>Catalog no. Lineside Loadside Sym. (kA) max Type Max amp size (in.)<br>**----- End of picture text -----**<br>
|PDB220|2/0 - 8|4 - 10<br>65<br>480<br>EGC125, E125C, EGH125, E125H<br>125<br>16 x 16 x 6.75<br>12<br>22<br>480<br>EGC125, E125C, EGE125, E125E, EGS125, E125S,<br>EGH125, E125H<br>125<br>14<br>14<br>480<br>EGC125, E125C, EGB125, E125B, EGE125, E125E,<br>EGS125, E125S, EGH125, E125H<br>125|
|---|---|---|
||2/0 - 8||
||2/0 - 8||
|PDB321|2/0 - 8|4 - 10<br>65<br>480<br>EGC125, E125C, EGH125, E125H<br>125<br>24 x 20 x 6.75<br>12<br>22<br>480<br>EGC125, E125C, EGE125, E125E, EGS125, E125S,<br>EGH125, E125H<br>125<br>14<br>14<br>480<br>EGC125, E125C, EGB125, E125B, EGE125, E125E,<br>EGS125, E125S, EGH125, E125H<br>125|
||2/0 - 8||
||2/0 - 8||
|PDB323|350 - 4|4 - 6<br>65<br>480<br>JGH250, J250H<br>250<br>24 x 20 x 6.75<br>8<br>42<br>480<br>JGH250, J250H<br>250<br>10<br>14<br>480<br>JGH250, J250H, JGE250, J250E, JGS250, J250S,<br>250<br>4 - 6<br>65<br>480<br>JGC250, J250C, JGU250, J250U, JGX250, J250X<br>250<br>8<br>42<br>10<br>25<br>8<br>50<br>10<br>25|
||350 - 4||
||350 - 4||
||350 - 4||
|PDB370|350 - 4|4 - 6<br>65<br>480<br>JGH250, J250H<br>250<br>24 x 20 x 6.75<br>8<br>42<br>480<br>JGH250, J250H<br>250<br>10<br>14<br>480<br>JGH250, J250H, JGE250, J250E, JGS250, J250S,<br>250<br>4 - 6<br>65<br>480<br>JGC250, J250C, JGU250, J250U, JGX250, J250X<br>250<br>8<br>42<br>10<br>25|
||350 - 4||
||350 - 4||
||350 - 4||
|PDB371|350 - 4|4 - 6<br>50<br>480<br>JGH250, J250H<br>250<br>24 x 20 x 6.75<br>8<br>42<br>480<br>JGH250, J250H<br>250<br>10<br>14<br>480<br>JGH250, J250H, JGE250, J250E, JGS250, J250S,<br>250<br>4 - 6<br>65<br>480<br>JGC250, J250C, JGU250, J250U, JGX250, J250X<br>250<br>8<br>50<br>10<br>25|
||350 - 4||
||350 - 4||
||350 - 4||
Data sheet no. 10537
Eaton.com/bussmannseries
9-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Power distribution and terminal blocks — 9**
## 160, 162, 163, 164 and 165 UL Recognized open power distribution blocks
UL Recognized power distribution blocks offer a variety of lineside and loadside port configurations for greater flexibility in panel wiring and wire management.
These blocks are UL Recognized to UL 1059 and rated for use in UL 508A industrial control panels.
Blocks are factory configured in 1-, 2 and 3-pole versions, and have optional covers to enhance safety (order covers separately).
## Ratings
- Volts 600 V
- Amps 175 to 1520 A
- SCCR up to 200 kA* (see table for SCCR by catalog number)
- Maximum SCCR contingent upon the application of an upstream current-limiting overcurrent protective device. See table for fusing requirements.
## Conductors[†]
- Stranded 75°C copper and aluminum
- Higher temperature rated conductors permitted with appropriate derating
- As specified in the catalog number table.
## Agency information
Dual wire port application
- Rated for dual wire port application to increase the possible number of lineside and loadside connections. E.g., 16220-1 can accept two wires into the lineside port (4 - 14 Cu, 4 - 8 Al) and two wires per port (eight connections total) on the loadside lug (8 - 14 Cu, 8 Al).
- Dual wire applications are only viable when using two wires of the same size, stranding, and insulating and conductor material.
## Ferrule terminal application
- Bussmann series UL Recognized power distribution blocks are rated for use with UL Listed ferrules (see catalog number table for details).
- Ferrule applications allow for the use of a broader range of conductor stranding and simulate a more efficient, solid wire connection with the terminal port.
- Always use UL Listed ferrules in accordance with the manufacturer’s specifications and instructions.
Optional covers
|Optional covers|Optional covers|
|---|---|
|For block catalognumber starting<br>Order cover catalognumber<br>160__<br>CPB160-(poles)*<br>~~|~~||
|162__|CPB162-(poles)*|
|163__|CPDB-(poles)*|
|165__|CPDB165**|
- Order one cover for each block by specifying the number of poles in the catalog number suffix. E.g., For the block catalog number 16021-4, order the cover catalog number CPD160-4.
- ** Order one cover for each of the block’s poles. E.g., For block catalog number 16530-3, order three of cover catalog number CPDB165.
- UL 1059 Recognized, Guide XCFR2, File E62622
- CSA Certified, Class 6228-01, File 15364
## Flammability rating
- UL 94 V0
## Optional covers
- See table for catalog numbers and ordering details
## How to order
From the catalog number tables, select the catalog number that defines the desired lineside/loadside port and conductor characteristics.
Add to the catalog number the suffix that defines the desired pole configuration. Note, you must select from the available number of poles for each catalog number. These appear in the second column of the catalog number tables.
## Catalog number example — 16220-3 is a 3-pole 16220
## Where:
- The prefix “16220” defines the block’s lineside characteristics (i.e., one conductor port per pole that accepts 2/0 - 14 Cu, or 2/0 - 8 Al conductors) and the loadside characteristics (i.e., four conductor ports per pole that each accepts 4 - 14 Cu or 4 - 8 Al conductors)
- The suffix “3” in this example defines this as a three-pole block
- See the catalog number tables for details on the available lineside/ loadside characteristics
Data sheet no. 10533
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
9-9
## **9 — Power distribution and terminal blocks**
**==> picture [537 x 543] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lineside Loadside<br>Current Wires Torque Wires Torque Max<br>Line/load port No. of rating Wire size (Sol/ferrule per N•m Ports/ Wire size (Sol/ferrule per N•m Ports/ SCCR<br>configuration poles (A) unless noted)* port (lb-in) pole unless noted)* port (lb-in) pole (kA)† Catalog no.<br>2/0 - 1 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>2 - 3 Cu/Al 1 8 Cu 1<br>2, 3, 4 175 13.6 (120) 1 2.8 (25) 6 10 16021-_<br>4 - 8 Cu/Al 1-2 8 Al (Str) 1-2<br>10 - 14 Cu 1-2 10 - 14 Cu 1-2 2.3 (20)<br>2/0 - 1 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>2 - 3 Cu/Al 1 8 Cu 1<br>1, 2, 3 175 13.6 (120) 1 2.8 (25) 4 200 16220-_<br>4 - 8 Cu/Al 1-2 8 Al (Str) 1-2<br>10 - 14 Cu 1-2 10 - 14 Cu 1-2 2.3 (20)<br>2/0 - 1 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>2 - 3 Cu/Al 1 8 Cu 1 16220-<br>1, 2, 3 175 13.6 (120) 1 2.8 (25) 4 200<br>4 - 8 Cu/Al 1-2 8 Al (Str) 1-2 _H [†††]<br>10 - 14 Cu 1-2 10 - 14 Cu 1-2 2.3 (20)<br>2/0 - 1 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>2 - 3 Cu/Al 1 8 Cu 1<br>1, 2, 3 175 13.6 (120) 1 2.8 (25) 6 200 16321-_<br>4 - 8 Cu/Al 1-2 8 Al (Str) 1-2<br>10 - 14 Cu 1-2 10 - 14 Cu 1-2 2.3 (20)<br>350kcmil - 2/0 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>8 Cu 1<br>1/0 Cu/Al (Str) 1-2 2.8 (25)<br>2,3,4 310 31.1 (275) [††] 1 8 Al (Str) 1-2 6 10 16023-_<br>10 - 12 Al (Str) 1<br>1 - 6 Cu/Al 1-2 2.3 (20)<br>10 - 14 Cu 1-2<br>350kcmil - 2/0 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>8 Cu 1<br>1/0 Cu/Al (Str) 1-2 2.8 (25)<br>1, 2, 3 310 31.1 (275) [††] 1 8 Al (Str) 1-2 6 200 16323-_<br>10 - 12 Al (Str) 1<br>1 - 6 Cu/Al 1-2 2.3 (20)<br>10 - 14 Cu 1-2<br>2 - 3 Cu/Al (Str) 1 5.6 (50)<br>4 Cu/Al 1<br>350kcmil - 2/0 Cu/Al (Str) 1 5.1 (45)<br>6 Cu/Al 1-2 3<br>8 Cu/Al 1-2 4.5 (40)<br>1, 2, 3 310 31.1 (275) [††] 1 10 - 14 Cu 1-2 4.0 (35) 10 16332-_<br>1/0 Cu/Al (Str) 1-2 1/0 - 3 Cu/Al (Str) 1<br>4 Cu 1<br>13.6 (120) 2<br>4 - 8 Al (Str) 1-2<br>1 - 6 Cu/Al 1-2<br>6 - 14 Cu 1-2<br>350kcmil - 2/0 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>8 Cu 1<br>1/0 Cu/Al (Str) 1-2 2.8 (25)<br>1, 2, 3 310 31.1 (275) [††] 1 8 Al (Str) 1-2 12 200 16370-_<br>10 - 12 Al (Str) 1<br>1 - 6 Cu/Al 1-2 2.3 (20)<br>10 - 14 Cu 1-2<br>2 - 3 Cu/Al (Str) 1 5.6 (50)<br>4 - 6 Cu/Al (Str) 1 5.1 (45)<br>350kcmil - 2/0 Cu/Al (Str) 1 6<br>8 Cu/Al (Str) 1 4.5 (40)<br>10 - 14 Cu (Str) 1 4.0 (35)<br>1, 2, 3 310 31.1 (275) [††] 1 1/0 - 3 Cu/Al (Str) 1 200 16371-_<br>1/0 Cu/Al (Str) 1-2 4 - 8 Cu/Al 1<br>10 - 14 Cu 1 13.6 (120) 3<br>6 - 14 Cu 2<br>1 - 6 Cu/Al 1-2<br>4 - 8 Al (Str) 2<br>350kcmil - 2/0 Cu/Al (Str) 1 10 Cu/Al 1<br>1, 2, 3 310 1/0 Cu/Al (Str) 1-2 31.1 (275) [††] 1 0.8 (7) 21 10 16372-_<br>12 - 14 Cu 1<br>1 - 6 Cu/Al 1-2<br>**----- End of picture text -----**<br>
- 75°C wire (higher temperature rated wire acceptable with appropriate derating). Using a ferrule on a stranded conductor requires a correctly sized UL Listed ferrule (customer supplied) applied according to the manufacturer’s specifications. Ferrule ratings apply to copper wire only.
- ** Not covered by CSA certification.
- See Short-Circuit Current Ratings table for the tested upstream overcurrent protective devices necessary for achieving these SCCRs.
- †† Torque rating for dual wire and ferrule application is 30.5 N•m (270 lb-in).
- ††† Configuration includes hex screws.
Data sheet no. 10533
Eaton.com/bussmannseries
9-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
## **Power distribution and terminal blocks — 9**
**==> picture [537 x 379] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lineside Loadside<br>Current Wires Torque Wires Torque Max<br>Line/load port No. of rating Wire size (Sol/ferrule per N•m Ports/ Wire size (Sol/ferrule per N•m Ports/ SCCR Catalog<br>configuration poles (A) unless noted)* port (lb-in) pole unless noted)* port (lb-in) pole (kA) [†] no.<br>10 Cu/Al 1<br>0.8 (7) 14<br>350kcmil - 2/0 Cu/Al (Str) 1 12 - 14 Cu 1<br>1/0 - 3 Cu/Al (Str) 1<br>16373-<br>1, 2, 3 310 31.1 (275) [††] 1 4 Cu 1 10<br>1/0 Cu/Al (Str) 1-2 6 - 14 Cu 1-2 13.6 (120) 3 _<br>4 - 8 Al (Str) 1-2<br>1 - 6 Cu/Al 1-2 10 - 14 Al (Str) 1<br>2/0 - 1 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>2 - 3 Cu/Al 1 8 Cu 1 16325-<br>1, 2, 3 350 13.6 (120) 2 2.8 (25) 6 10<br>4 - 8 Cu/Al 1-2 8 Al (Str) 1-2 _<br>10 - 14 Cu 1-2 10 - 14 Cu 1-2 2.3 (20)<br>2 - 3 Cu/Al (Str) 1 5.6 (50)<br>500kcmil - 4/0 Cu/Al (Str) 1<br>4 Cu/Al 1<br>5.1 (45)<br>6 Cu/Al 1-2 16330-<br>1, 2, 3 380 3/0 - 1/0 Cu/Al (Str) 1-2 56.5 (500) 1 6 10<br>8 Cu/Al 1-2 4.5 (40) _<br>10 - 12 Al (Str) 1<br>1 - 6 Cu/Al 1-2 4.0 (35)<br>10 - 14 Cu 1-2<br>2 - 3 Cu/Al (Str) 1 5.6 (50)<br>500kcmil - 4/0 Cu/Al (Str) 1 4 Cu/Al 1<br>5.1 (45)<br>6 Cu/Al 1-2 3<br>8 Cu/Al 1-2 4.5 (40)<br>16335-<br>1, 2, 3 380 3/0 - 1/0 Cu/Al (Str) 1-2 56.5 (500) 1 10 - 14 Cu 1-2 4.0 (35) 10<br>1/0 - 3 Cu/Al (Str) 1 _<br>4 Cu 1<br>13.6 (120) 2<br>1 - 6 Cu/Al 1-2 4 - 8 Al (Str) 1-2<br>6 - 14 Cu 1-2<br>500kcmil - 4/0 Cu/Al (Str) 1 6 Cu/Al (Str) 1 4.0 (35)<br>8 Cu 1<br>3/0 - 1/0 Cu/Al (Str) 1-2 2.8 (25)<br>1, 2, 3 380 56.5 (500) 1 8 Al (Str) 1-2 21 10 16541-_<br>10 - 14 Al (Str) 1<br>1 - 6 Cu/Al 1-2 2.3 (20)<br>10 - 14 Cu 1-2<br>4 - 6 Cu/Al (Str) 1 4.0 (35)<br>8 Cu 1<br>2.8 (25) 16375-<br>1, 2, 3 420 600kcmil - 2 Cu/Al (Str) 1 56.5 (500) 1 8 Al (Str) 1-2 12 10<br>10 - 12 Al (Str) 1 _<br>2.3 (20)<br>10 - 14 Cu 1-2<br>**----- End of picture text -----**<br>
- 75°C wire (higher temperature rated wire acceptable with appropriate derating). Using a ferrule on a stranded conductor requires a correctly sized UL Listed ferrule (customer supplied) applied according to the manufacturer’s specifications. Ferrule ratings apply to copper wire only.
- See Short-Circuit Current Ratings table for the tested upstream overcurrent protective devices necessary for achieving these SCCRs.
- †† Dual wire and ferrule application torque rating = 30.5 N•m (270 lb-in).
## Short-Circuit Current Rating (SCCR) data
**==> picture [537 x 43] intentionally omitted <==**
**----- Start of picture text -----**<br>
Conductors (AWG/kcmil) Fuse Class/Bussmann series symbol/amp rating<br>RK1 — LPN-RK RK5 — FRN-R (250<br>No. of (250 V), V), T — JJN (300 V),<br>Catalog no. poles Lineside Loadside J — LPJ LPS-RK (600 V) FRS-R (600 V) JJS (600 V) SCCR (kA)<br>**----- End of picture text -----**<br>
|16220-_<br>1, 2, 3<br>2/0 - 8|4 - 12|200<br>200<br>60<br>200<br>200|
|---|---|---|
||4 - 14|175<br>100<br>60<br>175<br>100|
|16321-_<br>1, 2, 3<br>2/0 - 8|4 - 12|400<br>200<br>100<br>400<br>200|
|||175<br>100<br>60<br>175<br>100|
|16323-_<br>1, 2, 3<br>350 - 4|4 - 8|400<br>200<br>100<br>400<br>200|
||4 - 12|175<br>100<br>60<br>175<br>100|
|16370-_<br>1, 2, 3<br>350 - 4|4 - 8|400<br>200<br>100<br>400<br>200|
||4 - 14|175<br>100<br>60<br>175<br>100|
|16371-_<br>1, 2, 3<br>350 - 4|1/0 - 6|400<br>200<br>100<br>400<br>200|
||1/0 - 12|175<br>100<br>60<br>175<br>100|
Data sheet no. 10533
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
9-11
## **9 — Power distribution and terminal blocks**
**==> picture [537 x 358] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lineside Loadside<br>Current Wire size Wires Wire size Wires Max<br>Line/load port No. of rating (Str/ferrule unless per Torque Ports/ (Str/ferrule unless per Torque Ports/ SCCR Catalog<br>configuration poles (A) noted)* port N•m (lb-in) pole noted)* port N•m (lb-in) pole (kA)† no.<br>2 - 3 Cu/Al (Str) 1 5.6 (50)<br>4 Cu/Al 1<br>5.1 (45)<br>6 Cu/Al 1-2 6<br>8 Cu/Al 1-2 4.5 (40)<br>1, 2, 3 420 600kcmil - 2 Cu/Al (Str) 1 56.5 (500) 1 10 - 14 Cu 1-2 4.0 (35) 10 16376-_<br>1/0 - 3 Cu/Al (Str) 1<br>4 Cu 1<br>13.6 (120) 3<br>6 - 14 Cu 1-2<br>4 - 8 Al (Str) 1-2<br>300kcmil - 2/0 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>1/0 Cu/Al (Str) 1-2 8 Cu 1<br>2.8 (25)<br>1, 2, 3 570 1 - 2 Cu/Al 1-2 31.1 (275) [††] 2 8 Al (Str) 1-2 12 10 16377-_<br>10 - 12 Al (Str) 1<br>4 Cu/Al (Str) 1-2 2.3 (20)<br>10 - 14 Cu 1-2<br>500kcmil - 4/0 Cu/Al (Str) 1 4 - 6 Cu/Al (Str) 1 4.0 (35)<br>3/0 - 1/0 Cu/Al (Str) 1-2 8 Cu 1<br>2.8 (25)<br>1, 2, 3 760 56.5 (500) 2 8 Al (Str) 1-2 12 10 16530-_<br>10 - 14 Al (Str) 1<br>1 - 6 Cu/Al 1-2 2.3 (20)<br>10 - 14 Cu 1-2<br>3/0 - 6 Cu/Al (Str) 1 13.6 (120) 4<br>4 - 6 Cu/Al (Str) 1 4.0 (35)<br>8 Cu 1<br>1, 2, 3 840 600kcmil - 2 Cu/Al 1 56.5 (500) 2 2.8 (25) 10 16528-_<br>8 Al (Str) 1-2 4<br>10 - 14 Al (Str) 1<br>2.3 (20)<br>10 - 14 Cu 1-2<br>2 - 3 Cu/Al (Str) 1 5.6 (50)<br>500kcmil - 4/0 Cu/Al (Str) 1 4 Cu/Al 1<br>5.1 (45)<br>6 Cu/Al 1-2 22<br>8 Cu/Al 1-2 4.5 (40)<br>1 1520 56.5 (500) 4 10 - 14 Cu 1-2 4.0 (35) 10 16400<br>3/0 - 1/0 Cu/Al (Str) 1-2<br>1/0 - 3 Cu/Al (Str) 1<br>4 Cu 1<br>13.6 (120) 6<br>4 - 8 Al (Str) 1-2<br>1 - 6 Cu/Al 1-2<br>6 - 14 Cu 1-2<br>**----- End of picture text -----**<br>
- 75°C wire (higher temperature rated wire acceptable with appropriate derating). Using a ferrule on a stranded conductor requires a correctly sized UL Listed ferrule (customer supplied) applied according to the manufacturer’s specifications. Ferrule ratings apply to copper wire only.
- See Short-Circuit Current Ratings table for the tested upstream overcurrent protective devices necessary for achieving these SCCRs.
- †† Dual wire and ferrule application torque rating = 30.5 N•m (270 lb-in).
Data sheet no. 10533
Eaton.com/bussmannseries
9-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Power distribution and terminal blocks — 9**
## 162, 163 and 165 UL Recognized stud power terminal blocks
Port-to-stud and stud-to-stud power terminal blocks are available with current ratings up to 760 A. These blocks provide a convenient stud connection means for lug/ring wire terminals.
Factory configured from 1- to 3-poles (catalog number dependent) with optional covers to enhance safety (order covers separately), these blocks are UL Recognized to UL 1059 and rated for use in UL 508A industrial control panels.
## Ratings
- Volts 600 V
- Amps 150 up to 760 A
- SCCR up to 200 kA* (see table for SCCR by catalog number)
- Maximum SCCR contingent upon the application of an upstream current-limiting overcurrent protective device. See table for fusing requirements.
## Conductors[†]
- Stranded 75°C copper and aluminum
- Higher temperature rated conductors permitted with appropriate derating
- As specified in the catalog number table.
## Agency information
- UL 1059 Recognized, Guide XCFR2, File E62622
- CSA Certified, Class 6228-01, File 15364
## Flammability rating
- UL 94 V0
## Optional covers
- See table for catalog numbers specific to each block
## How to order
From the catalog number tables, select the catalog number that defines the desired lineside/loadside port and conductor characteristics.
Add to the catalog number the suffix that defines the desired pole configuration. Note, you must select from the available number of poles for each catalog number. These appear in the second column of the catalog number tables.
Catalog number example — 16280-3 is a 3-pole 16280
## Where:
- The prefix “16280” defines the block’s lineside characteristics (i.e., one conductor port per pole that accepts 2/0 - 14 Cu/Al conductors) and the loadside characteristics (i.e., 1/4-20 x 3/4” stud)
- The suffix “3” in this example defines this as a three-pole block
- See the catalog number tables for details on the available lineside/ loadside characteristics
## Dual wire port application
- Rated for dual wire port application to increase the possible number of lineside and loadside connections. E.g., 16280-1 can accept two wires into the lineside port (#4 - #8 Cu/Al, #10 - #14 Cu).
- Dual wire applications are only viable when using two wires of the same size, stranding, and insulating and conductor material in the same port
## Ferrule terminal application
- Bussmann series stud blocks are rated for use with UL Listed ferrules (see catalog number table for details). Ferrule ratings apply to copper wire only.
- Ferrule applications allow for the use of a broader range of conductor stranding and simulate a more efficient, solid wire connection with the terminal port
- Always use UL Listed ferrules in accordance with the manufacturer’s specifications and instructions
## Optional covers
Electrical safety can be enhanced by installing optional covers. From the table below, order the cover catalog number that matches the block catalog number.
|Block catalogno.|Poles|Cover catalogno.|
|---|---|---|
|16280-1|1|CPB162-1*|
|16280-2|2|CPB162-2*|
|16280-3|3|CPB162-3*|
|16280-2-M|2|CPB162-2*|
|16280-3-M<br>16281-1|3<br>1|CPB162-3*<br>CPB162-1*|
|16281-2|2|CPB162-2*|
|16281-3|3|CPB162-3*|
|16290-1|1|CPB162-1*|
|16290-2|2|CPB162-2*|
|16290-3<br>16378-1|3<br>1|CPD162-3*<br>CPDB-1*|
|16378-2|2|CPDB-2*|
|16378-3|3|CPDB-3*|
|16383-1<br>16383-2|1<br>2|CPDB-1*<br>CPDB-2*|
|16383-3<br>16390-1|3<br>1|CPDB-3*<br>CPDB-1*|
|16390-2<br>16390-3|2<br>3|CPDB-2*<br>CPDB-3*|
|16392-1-H<br>16392-2-H<br>16392-3-H<br>16394-1|1<br>2<br>3<br>1|CPDB-1*<br>CPDB-2*<br>CPDB-3*<br>CPDB-1*|
|16394-2|2|CPDB-2*|
|16394-3|3|CPDB-3*|
|16395-1|1|CPDB-1*|
|16395-2|2|CPDB-2*|
|16395-3|3|CPDB-3*|
|16582-1|1|CPDB165**|
|16582-2|2|CPDB165**|
|16582-3|3|CPDB165**|
|16591-1|1|CPDB165**|
|16591-2|2|CPDB165**|
|16591-3<br>16593-1<br>16593-2<br>16593-3|3<br>1<br>2<br>3|CPDB165**<br>CPDB165**<br>CPDB165**<br>CPDB165**|
- Cover catalog number provides one individual cover for each block.
- ** Order one cover for each pole.
Data sheet no. 10535
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
9-13
## **9 — Power distribution and terminal blocks**
**==> picture [537 x 546] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lineside Loadside<br>Current Wires Torque<br>Line/load No. of rating Wire/stud size per N•m Ports/ Stud/ Studs/ SCCR<br>configuration poles (A) (Str/ferrule unless noted)* port (lb-in) pole connector size pole (kA) Catalog no.<br>Connector - to - stud<br>2/0 - 1 Cu/Al (Str)<br>1<br>2 - 3 Cu/Al<br>1, 2, 3 175 13.6 (120) 1 1/4-20 x 3/4” stud 1 200 [†] 16280-_**<br>4 - 8 Cu/Al<br>1-2<br>10 - 14 Cu<br>2/0 - 1 Cu/Al (Str)<br>1<br>2 - 3 Cu/Al<br>2, 3 175 13.6 (120) 1 M6 x 1” stud 1 200 [†] 16280-_-M<br>4 - 8 Cu/Al<br>1-2<br>10 - 14 Cu<br>2/0 - 1 Cu/Al (Str)<br>1<br>2 - 3 Cu/Al<br>1, 2, 3 175 13.6 (120) 1 1/4-20 tapped hole 1 10 16281-_**<br>4 - 8 Cu/Al<br>1-2<br>10 - 14 Cu<br>500kcmil - 4/0 Cu/Al (Str) 1<br>1, 2, 3 380 3/0 - 1/0 Cu/Al (Str) 56.5 (500) 1 1/4-20 x 1” stud 2 10 16378-_<br>1-2<br>1 - 6 Cu/Al<br>500kcmil - 4/0 Cu/Al (Str) 1<br>1, 2, 3 380 3/0 - 1/0 Cu/Al (Str) 56.5 (500) 1 3/8-16 x 1” stud 1 10 16383-_<br>1-2<br>1 - 6 Cu/Al<br>500kcmil - 4/0 Cu/Al (Str) 1<br>1, 2, 3 760 3/0 - 1/0 Cu/Al (Str) 56.5 (500) 2 3/8-16 x 1-5/8” stud 2 10 16582-_<br>1-2<br>1 - 6 Cu/Al<br>Stud - to - stud<br>1, 2, 3 175 1/4-20 x 3/4” stud 1 1/4-20 x 3/4” stud 1 10 16290-_**<br>1, 2, 3 250 3/8-16 x 1-1/8” stud 1 3/8-16 x 1-1/8” stud 1 10 16390-_<br>1, 2, 3 310 3/8-16 x 1-7/16” stud 1 1/4-20 x 9/16” stud 2 10 16395-_<br>1, 2, 3 400 3/8-16 x 1-1/8” stud 1 3/8-16 x 1-1/8” stud 1 10 16392-_-H [††]<br>1, 2, 3 400 1/2-13 x 1-1/16” stud 1 1/2-13 x 1-1/16” stud 1 10 16394-_<br>1, 2, 3 400 3/8-16 x 1-7/16” stud 1 3/8-16 x 1-7/16” stud 2 10 16591-_**<br>1, 2, 3 600 1/2-13 x 1” stud 1 1/2-13 x 1” stud 1 10 16593-_<br>**----- End of picture text -----**<br>
- 75°C wire (higher temperature rated wire acceptable with appropriate derating). Using a ferrule on a stranded conductor requires a correctly sized UL Listed ferrule (customer supplied) applied according to the manufacturer’s specifications. Ferrule ratings apply to copper wire only.
- ** Not covered by CSA certification.
- See table below for the tested upstream overcurrent protective devices necessary for achieving this SCCR.
- †† Configuration includes washers and hex nuts for each stud.
Short-Circuit Current Rating (SCCR) data for block 16280-_
**==> picture [537 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
Conductors (AWG) Fuse class/Bussmann series symbol/amp rating<br>Class RK1 Class RK5 Class T<br>Catalog No. of Class J LPN-RK (250 V) FRN-R (250 V) JJN (300 V)<br>no. poles Lineside Loadside LPJ LPS-RK (600 V) FRS-R (600 V) JJS (600 V) SCCR (kA)<br>16280-_ 1, 2, 3 2/0 - 8 1/4-20x3/4 stud 200 200 60 200 200<br>**----- End of picture text -----**<br>
Data sheet no. 10535
Eaton.com/bussmannseries
9-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Power distribution and terminal blocks — 9**
## 160, 162, 163 and 165 UL Recognized power splicer blocks
Splicer blocks allow for increasing or decreasing wire size within a circuit to accommodate different connections from the power source to the branch load.
These blocks are factory configured from 1- to 4-poles (catalog number dependent) for wire sizes up to 500kcmil and amp ratings up to 760 A. Optional covers are available to enhance safety (order covers separately).
These blocks are UL Recognized to UL 1059 and rated for use in UL 508A industrial control panels.
## Ratings
- Volts 600 V
- Amps 115 to 760 A
## Dual wire port application
- Rated for dual wire port application to increase the possible number of lineside and loadside connections. E.g., 16303-1 can accept two wires into the lineside port (1/0 - #6 Cu/Al) and two wires per port (2 connections per pole total) on the loadside lug (1/0 - #6 Cu/Al).
- Dual wire applications are only viable when using two wires of the same size, stranding, and insulating and conductor material in the same port.
## Ferrule terminal application
- Bussmann series splicer blocks are rated for use with UL Listed ferrules (see catalog number table for details). Ferrule ratings apply to copper wire only.
- Ferrule applications allow for the use of a broader range of conductor stranding and simulate a more efficient, solid wire connection with the PDB terminal port
- Always use UL Listed ferrules in accordance with the manufacturer’s specifications and instructions
## Optional covers
- SCCR up to 200 kA* (see table for SCCR by catalog number)
- Maximum SCCR contingent upon the application of an upstream current-limiting overcurrent protective device. See table for fusing requirements.
Electrical safety can be enhanced by installing optional covers. From the table below, order the cover catalog number that matches the block catalog number.
## Conductors[†]
- Stranded 75°C copper and aluminum
- Higher temperature rated conductors permitted with appropriate derating
- As specified in the catalog number table.
## Agency information
- UL 1059 Recognized, Guide XCFR2, File E62622
- CSA[®] Certified, Class 6228-01, File 15364
## Flammability rating
- UL 94 V0
## Optional covers
- See table for catalog numbers specific to each block
## How to order
From the catalog number tables, select the catalog number that defines the desired lineside/loadside port and conductor characteristics.
Add to the catalog number the suffix that defines the desired pole configuration. Note, you must select from the available number of poles for each catalog number. These appear in the second column of the catalog number tables.
Catalog number example — 16204-3 is a 3-pole 16204
Where:
- The prefix “16204” defines the block’s lineside and loadside characteristics (i.e., conductor port per pole that accepts 2/0 - #14 Cu, or 2/0 - #12 Al conductors)
- The suffix “3” in this example defines this as a three-pole block
- See the catalog number tables for details on the available lineside/ loadside characteristics
|Block catalogno.|Poles|Cover catalogno.|
|---|---|---|
|16000-2|2|CPB160-2*|
|16000-3|3|CPB160-3*|
|16000-4|4|CPB160-4*|
|16003-2|2|CPB160-2*|
|16003-3|3|CPB160-3*|
|16003-4|4|CPB160-4*|
|16005-2|2|CPB160-2*|
|16005-3|3|CPB160-3*|
|16005-4|4|CPB160-4*|
|16200-1|1|CPB162-1*|
|16200-2|2|CPB162-2*|
|16200-3|3|CPB162-3*|
|16201-1|1|CPB162-1*|
|16201-2|2|CPB162-2*|
|16201-3|3|CPB162-3*|
|16204-1|1|CPB162-1*|
|16204-2|2|CPB162-2*|
|16204-3|3|CPD162-3*|
|16301-1<br>16301-2|1<br>2|CPDB-1*<br>CPDB-2*|
|16301-3|3|CPDB-3*|
|16303-1<br>16303-2<br>16303-3|1<br>2<br>3|CPDB-1*<br>CPDB-2*<br>CPDB-3*|
|16306-1|1|CPDB-1*|
|16306-2|2|CPDB-2*|
|16306-3|3|CPDB-3*|
|16500-1<br>16500-2<br>16500-3<br>16504-1<br>16504-2<br>16504-3|1<br>2<br>3<br>1<br>2<br>3|CPDB165**<br>CPDB165**<br>CPDB165**<br>CPDB165**<br>CPDB165**<br>CPDB165**|
- Cover catalog number provides one individual cover for each block.
- ** Order one cover for each pole.
Data sheet no. 10534
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
9-15
## **9 — Power distribution and terminal blocks**
**==> picture [544 x 484] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lineside Loadside<br>No. Current Wire size Wires Torque Wire size Wires Torque<br>Line/load port of rating (Str/ferrule unless per N•m Ports/ (Str/ferrule unless per N•m Ports/ SCCR Catalog<br>configuration poles (A) noted)* port (lb-in) Pole noted)* port (lb-in) pole (kA) no.<br>2 - 3 Cu/Al (Str) 1 5.6 (50) 2 - 3 Cu/Al (Str) 1 5.6 (50)<br>4 - 6 Cu/Al (Str) 1 5.1 (45) 4 - 6 Cu/Al (Str) 1 5.1 (45)<br>1, 2, 3 115 1 1 10 16200-_**<br>8 Cu/Al (Str) 1 4.5 (40) 8 Cu/Al (Str) 1 4.5 (40)<br>10 - 14 Cu (Str) 1 4.0 (35) 10 - 14 Cu (Str) 1 4.0 (35)<br>1/0 - 3 Cu (Str) 1 5.6 (50) 1/0 - 3 Cu (Str) 1 5.6 (50)<br>4 - 6 Cu (Str) 1 5.1 (45) 4 - 6 Cu (Str) 1 5.1 (45)<br>1, 2, 3 150 1 1 10 16201-_<br>8 Cu (Str) 1 4.5 (40) 8 Cu (Str) 1 4.5 (40)<br>10 - 14 Cu (Str) 1 4.0 (35) 10 - 14 Cu (Str) 1 4.0 (35)<br>2/0 - 1 Cu/Al (Str) 1 2/0 - 1 Cu/Al (Str) 1<br>12.4 (110) 12.4 (110)<br>2 - 8 Cu/Al 1 2 - 8 Cu/Al 1<br>10 - 12 Al (Str) 1 10 - 12 Al (Str) 1<br>2, 3, 4 175 4.0 (35) 1 4.0 (35) 1 10 16000-_**<br>10 - 14 Cu 1 10 - 14 Cu 1<br>4 - 8 Cu/Al 2 4 - 8 Cu/Al 2<br>13.6 (120) 13.6 (120)<br>10 - 14 Cu 2 10 - 14 Cu 2<br>2/0 - 1 Cu/Al (Str) 1 2/0 - 1 Cu/Al (Str) 1<br>12.4 (110) 12.4 (110)<br>2 - 8 Cu/Al 1 2 - 8 Cu/Al 1<br>10 - 12 Al (Str) 1 10 - 12 Al (Str) 1<br>1, 2, 3 175 4.0 (35) 1 4.0 (35) 1 200 [†] 16204-_<br>10 - 14 Cu 1 10 - 14 Cu 1<br>4 - 8 Cu/Al 2 4 - 8 Cu/Al 2<br>13.6 (120) 13.6 (120)<br>10 - 14 Cu 2 10 - 14 Cu 2<br>2, 3, 4 255 250kcmil - 6 Cu 1 42.4 (375) 1 250kcmil - 6 Cu 1 42.4 (375) 1 10 16003-_**<br>1, 2, 3 255 250kcmil - 6 Cu 1 42.4 (375) 1 250kcmil - 6 Cu 1 42.4 (375) 1 10 16301-_<br>350kcmil - 2/0 Cu/Al (Str) 1 350kcmil - 2/0 Cu/Al (Str) 1<br>1/0 Cu/Al (Str) 1-2 31.1 1/0 Cu/Al (Str) 1-2 31.1<br>2, 3, 4 310 1 1 10 16005-_**<br>(275) [††] (275) [††]<br>1 - 6 Cu/Al 1-2 1 - 6 Cu/Al 1-2<br>350kcmil - 2/0 Cu/Al (Str) 1 350kcmil - 2/0 Cu/Al (Str) 1<br>1, 2, 3 310 1/0 Cu/Al (Str) 1-2 31.1 1 1/0 Cu/Al (Str) 1-2 31.1 1 10 16303-_<br>(275) [††] (275) [††]<br>1 - 6 Cu/Al 1-2 1 - 6 Cu/Al 1-2<br>500kcmil - 4/0 Cu/Al (Str) 1 500kcmil - 4/0 Cu/Al (Str) 1<br>1, 2, 3 380 3/0 - 1/0 Cu/Al (Str) 1-2 56.5 (500) 1 3/0 - 1/0 Cu/Al (Str) 1-2 56.5 (500) 1 10 16306-_<br>1 - 6 Cu/Al 1-2 1 - 6 Cu/Al 1-2<br>350kcmil - 2/0 Cu/Al (Str) 1 350kcmil - 2/0 Cu/Al (Str) 1<br>1/0 Cu/Al (Str) 1-2 31.1 1/0 Cu/Al (Str) 1-2 31.1<br>1, 2, 3 620 2 2 10 16500-_<br>1 - 4 Cu/Al 1-2 (275) [††] 1 - 4 Cu/Al 1-2 (275) [††]<br>6 Cu/Al 2 6 Cu/Al 2<br>500kcmil - 4/0 Cu/Al (Str) 1 500kcmil - 4/0 Cu/Al (Str) 1<br>1, 2, 3 760 3/0 - 1/0 Cu/Al (Str) 1-2 56.5 (500) 2 3/0 - 1/0 Cu/Al (Str) 1-2 56.5 (500) 2 10 16504-_<br>1 - 6 Cu/Al 1-2 1 - 6 Cu/Al 1-2<br>**----- End of picture text -----**<br>
- 75°C wire (higher temperature rated wire acceptable with appropriate derating). Using a ferrule on a stranded conductor requires a correctly sized UL Listed ferrule (customer supplied) applied according to the manufacturer’s specifications. Ferrule ratings apply to copper wire only.
- ** Not covered by CSA certification.
- See table below for the tested upstream overcurrent protective devices necessary for achieving this SCCR.
- †† Torque rating for dual wire and ferrule application is 30.5 N•m (270 lb-in).
## Short-Circuit Current Rating (SCCR) data for block 16204-_
**==> picture [537 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
Conductors (AWG) Fuse class/Bussmann series symbol/amp rating<br>Class RK1 Class RK5 Class T<br>No. of Class J LPN-RK (250 V) FRN-R (250 V) JJN (300 V)<br>Catalog no. poles Lineside Loadside LPJ LPS-RK (600 V) FRS-R (600 V) JJS (600 V) SCCR (kA) Min. enclosure size<br>16204-_ 1, 2, 3 2/0 - 8 2/0 - 8 200 200 60 200 200 16 x 16 x 6.75<br>**----- End of picture text -----**<br>
Data sheet no. 10534
Eaton.com/bussmannseries
9-16
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Power distribution and terminal blocks — 9**
## 11675 250 V screw/quick connect power terminal block
Lineside screw connection, loadside 0.250" quick-connect (3 per pole) power terminal block available from 2 to 6 poles (see catalog number table).
## Ratings
- Volts 250 Vac/dc
- Amps Up to 40 A
- SCCR 10 kA per UL 508A, Table SB4.1
## Agency information
- UL Recognized, Guide XCFR2, File E62622, CSA 47235, CE
## Conductors/torque ratings
11725 600 V screw/quick connect power terminal block
Lineside screw connection, loadside 0.250" quick-connect (4 per pole) power terminal block available in 2, 3 or 4 poles (see catalog number table).
## Ratings
- Volts 600 Vac/dc
- Amps up to 70 A
- SCCR 10 kA per UL 508A Table SB4.1
## Agency Information
- UL Recognized, Guide XCFR2, File E62622, CSA 47235, CE
## Conductors/torque ratings
- 2 – 14 AWG Cu
- 8-14 AWG Cu.
- 9 lb-in (1.0 N•m) max.
Catalog no. (poles) 11675-2 11675-3 11675-4 11675-6
## 14002 600 V barrier terminal block
Barrier terminal block available from 2 to 6 poles with box lug terminals. 2- and 3-pole versions available with loadside 0.25" quickconnect terminals (4 per pole). See catalog numbers table.
- 8 AWG Al.
- 45 lb-in (5.1 N•m) max.
Catalog no. (poles) 11725-2 11725-3 11725-4
## 14004 600 V dead front terminal block
Dead front terminal block available from 2 to 12 poles (see catalog number table).
## Ratings
- Volts 600 Vac/dc
## Ratings
- Volts 600 Vac/dc
- Amps 115 A
- SCCR 10 kA per UL 508A Table SB4.1
- Amps 90 A
- SCCR 10 kA per UL 508A Table SB4.1
## Agency information
- UL Recognized, Guide XCFR2, File E62600, CSA 47235, CE
## Agency information
## Conductors
- UL Recognized, Guide XCFR2, File E62622, CSA 47235, CE
## Conductors/torque ratings*
- Wire; 2 – 14 AWG Cu, 8 AWG Al.
- Torque; 2-3 AWG 50 (5.6 N•m), 4-6 AWG 45 (5.1 N•m), 8 AWG 40 (4.5 N•m), 10-14 AWG 35 (3.9 N•m)
- 4 – 14 AWG Cu
- 8 AWG Al
## Marking
- Numeral marking molded into the top of the block is standard
* Consult factory for torque ratings on "Q" quick-connect terminal option.
## Marking
- Marking strip optional on 2- and 3-pole configurations. See catalog numbers table.
|Catalog no. (poles)||||
|---|---|---|---|
|14004-2|14004-5|14004-8|14004-12|
|14004-3|14004-6|14004-9||
|14004-4|14004-7|14004-10||
|Catalog no. (poles)<br>Standard<br>14002-2<br>14002-3|Catalog no. (poles)<br>14002-5<br>14002-6|Loadside quick-<br>connect terminals<br>Q14002-2<br>Q14002-3|Standard with<br>marking strip<br>14002-2A<br>14002-3A|
|---|---|---|---|
|14002-4||||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
9-17
**BUSSMANN** SERIES
## Calculate 7 ; available fault — . ben current anytime, anywhere
Eaton’s Bussmann™ series FC[2 ] Available Fault Current Calculator is a simple-to-use mobile and web-based application that calculates single- and three-phase system fault current levels.
The free tool is available for all Apple[®] iPhones, iPads, and Android™ mobile devices and allows you to quickly and easily determine available fault current levels anywhere in an electrical distribution system.
What’s more, FC[2] has English, Spanish and French modes to address local language and equipment marking requirements.
Download today from the Android or Apple store or visit Eaton.com/bussmannseries to learn more.
Follow us on social media to get the latest product and support information.
**Connector products — 10**
## Contents
|Connector products to simplify<br>wiring|Description<br>Section<br>page<br>Compact rail and panel mount blocks<br>NDN DIN-Rail and C-Rail feed through blocks<br>2-3<br>N512, NFT2, NFT3, NC3, NSE3, NSS3 C-Rail feed<br>through blocks<br>4-5<br>15188, PLU3, PLU1, PSU1 depluggable DIN-Rail and<br>C-Rail blocks<br>6-7|Connector|products|
|---|---|---|---|
||KT3, KT4 multi-pole panel mount blocks<br>7|||
||BNQ21, BQQ41 quick-connect panel mount blocks<br>8|||
|+f.tebi43 <br>=<br>iordaei<br>“449;|Power feed through terminal blocks<br>C7021 1- to 6-pole block<br>9<br>Double row terminal blocks<br>TB100 2- to 36-pole blocks<br>10-11<br>TB200 and TB200HB 2- to 30-pole blocks<br>12-13<br>TB300 and TB345 2- to 24-pole blocks<br>14-15<br>Accessories for double row terninal blocks<br>Marking options and covers<br>16<br>Top and bottom marking strips for terminal blocks<br>17<br>Double row terminal blocks continued<br>TB400 2- to 12-pole blocks<br>18<br> ~~a~~|||
||KU 2- to 12-pole blocks<br>19<br>Mounting accessories<br>End brackets<br>20<br>DIN-Rail and C-Rail mounting rails and brackets<br>~~—_~~<br>~~nn~~|||
Connector products to simplify wiring
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
10-1
## **10 — Connector products**
NDN DIN-Rail feed through blocks
**==> picture [530 x 518] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|The NDN feed through blocks|
|feature a compact line of|
|terminal blocks suitable for|
|both 35mm DIN-Rail or C-Rail|
|applications. Products easily|
|snap onto the mounting rail for a|
|quick, simple, low-cost solution.|
|Available accessories include|
|jumpers and marking tape.|
|UL E62622|
|CSA File 15364|
|NDNV4|NDN3|NDN63|
|CSA File 47235 (NDN1, NDN111)|
|Approval|Approval|Approval|
|Technical data|Technical data|Technical data|
|Rated voltage|600V|Rated voltage|600V|Rated voltage|600V|
|Rated Current|30A|Rated Current|30A|Rated Current|65A|
|Center spacing, in (mm)|0.25 / 6.35|Center spacing, in (mm)|0.3 / 7.62|Center spacing, in (mm)|0.375 / 9.52|
|Conductor cross-section, flexible (AWG/mm2)|22~10 / 0.3~5.3|Conductor cross-section, flexible (AWG/mm2)|22~10 / 0.3~5.3|Conductor cross-section, flexible (AWG/mm2)|18~6 / 0.8~13.3|
|Number of Poles|4|Number of Poles|3|Number of Poles|3|
|Circuits per foot|48|Circuits per foot|38|Circuits per foot|30|
|Torque(N•m)|2|Torque(N•m)|2|Torque(N•m)|4|
|Torque(lb-in)|18|Torque(lb-in)|18|Torque(lb-in)|35|
|Screw|#6-32|Screw|#6-32|Screw|#10-32|
|WxHxD(mm)|25.4|x|34|x|42.4|WxHxD(mm)|23.9 x 33.3 x 42.4|WxHxD(mm)|29.7 x 36.8 x 42.4|
|Colors|Cat. no.|Colors|Cat. no.|Colors|Cat. no.|
|Oo|White (standard)|NDNV4-WH|O|White (standard)|NDN3-WH|O|White (standard)|NDN63-WH|
|Block|
|Black|NDNV4-BK|Blue|NDN3-BL|Black|NDN63-BK|
|o|e|7|<=|
|Accessories|Cat. no.|Accessories|Cat. no.|Accessories|Cat. no.|
|Jumper|4 circuits|JN4|2 circuits|JNDN3|2 circuits|JN1|
|Marking tape|MTC6|MT12-1-2|MT12-1-2|
|DRL35MML|DRL35MML|DRL35MML|
|35mm DIN-Rail|35mm DIN-Rail|35mm DIN-Rail|
|DRL35MMHI|DRL35MMHI|DRL35MMHI|
|Mounting|NFTA|NFTA|NFTA|
|C-Rail|C-Rail|C-Rail|
|NRA|NRA|NRA|
|Modular option|—|—|—|—|—|—|
|Dimensions — in (mm)|Dimensions — in (mm)|Dimensions — in (mm)|
|(25.4)1.0|Markingtape|
|(42.41)1.67|(37.33)1.47|(31.24)1.23|(37.33)1.47|(38.10)1.50|
|q|TT|—||TK|fel|||1.67|——|
|||1|[[aaa]|1.67|(42.41)|
|a|,|Ll,|0d|]|(42.41)|Coo|||||| Ee|N|
|aLT|Bl]|(34.04)1.34|I.|0|E|.94|ytiy|¥|1.31|K||i:|(29.71)1.17|—|(36.83)1.45|_,|
|(23.87)|(33.27)|
|0|o|||||~_<—|—>||
**----- End of picture text -----**<br>
Eaton.com/bussmannseries
10-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Connector products — 10**
|NDN1||NDN111|
|---|---|---|
|Approval<br>Technical data<br>Rated voltage<br>600V<br>Rated Current<br>90A<br>Center spacing in (mm)<br>0.635 / 16.31<br>Conductor cross-section,<br>flexible (AWG/mm<br>2)<br>18~2 / 0.8~33.6<br>Number of Poles<br>3<br>Circuits per foot<br>18<br>Torque(N•m)<br>3.6<br>Torque(lb-in)<br>32<br>Screw<br>1/4-28<br>WxHxD(mm)<br>47.5 x 36.6 x 43.5<br>Colors<br>Cat. no.<br>White (standard)<br>NDN111-WH<br>Approval<br>Technical data<br>Rated voltage<br>600V<br>Rated Current<br>90A<br>Center spacing in (mm)<br>0.635 / 16.31<br>Conductor cross-section,<br>flexible (AWG/mm<br>2)<br>18~2 / 0.8~33.6<br>Number of Poles<br>1<br>Circuits per foot<br>18<br>Torque(N•m)<br>3.6<br>Torque(lb-in)<br>32<br>Screw<br>1/4-28<br>WxHxD(mm)<br>15 x 30.3 x 43.5<br>Colors<br>Cat. no.<br>White (standard)<br>NDN1-WH<br>~~==~~|||
|Accessories<br>Cat. no.<br>—<br>—<br>~~OO~~<br>~~ee ~~||Black<br>NDN111-BK<br>Accessories<br>Cat. no.<br>2 circuits<br>JN1<br> ~~|=~~|
|MT12-1-2||MT12-1-2|
|35mm DIN-Rail<br>DRL35MML<br>DRL35MMHI||35mm DIN-Rail<br>DRL35MML<br>DRL35MMHI|
|C-Rail<br>NFTA<br>NRA||C-Rail<br>NFTA<br>NRA|
|||NDN111A-WH, NDN111A-BK|
|Dimensions — in (mm)<br>~~Re~~||Dimensions — in (mm)<br>|~~hs~~|
0.18 (4.57) dia.Mtg. holes 0.28 (7.11) c'bores ~~1.46~~ (37.13) 1.71 1.71 1.32 (43.48) (43.48) (33.68) Dovetail option 0.62 (15.75) | Ae}| = (47.50)1.87 ~~-~~ Dovetail 0.59 1.43 Option (14.99) LoL (36.31) ~~So~~ h 1.44 IA (36.57)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
10-3
## **10 — Connector products**
C-Rail feed through terminal blocks 12-pole C-Rail terminal blocks provide a low-profile, compact footprint solution for various wire connection applications. Products feature an easy, snap-on installation method and an array of accessories including jumpers and marking strips.
UL E62622 (excluding N512) CSA File 15364
|CSA File 15364|CSA File 15364|||||||||
|---|---|---|---|---|---|---|---|---|---|
|CSA File 47235 (NFT3)|CSA File 47235 (NFT3)|N512<br>Approval||NFT2<br>Approval||||NFT3<br>Approval||
|||Technical data||Technical data||||Technical data||
|||Rated voltage|300V<br>600V|Rated voltage|600V|||Rated voltage|600V|
|||Rated current|20A<br>5A|Rated Current|40A|||Rated Current|40A|
|||Center spacing in (mm)|0.197 / 5.0|Center spacing in (mm)|0.28 / 7.13|||Center spacing in (mm)|0.39 / 9.91|
|||Conductor cross-section,<br>flexible (AWG/mm<br>2)|22~12 / 0.3~3.3|Conductor cross-section,<br>flexible (AWG/mm<br>2)|22~8 / 0.3~8.4|||Conductor cross-section,<br>flexible (AWG/mm<br>2)|22~8 / 0.3~8.4|
|||Number of Poles|12|Number of Poles|2|||Number of Poles|3|
|||Circuits per foot|60|Circuits per foot|38|||Circuits per foot|28|
|||Torque(N•m)|1.4|Torque(N•m)|2|||Torque(N•m)|2|
|||Torque(lb-in)|12|Torque(lb-in)|18|||Torque(lb-in)|18|
|||Screw|#4-48|Screw|#8-32|||Screw|#8-32|
|||WxHxD(mm)|61.0 x 27.7 x 22.4|WxHxD(mm)|16.5 x 34.7 x 42.8|||WxHxD(mm)|30.0 x 32.9 x 31.4|
|||Colors|Cat. no.|Colors|Cat. no.|||Colors|Cat. no.|
||Jumper<br>Block|Black (standard)<br>N512-BK<br>—<br>—<br>Accessories<br>Cat. no.<br>12 circuits<br>JN512<br>~~e~~<br>(2 ~~BO~~<br>~~ee ee~~||White (standard)<br>NFT2-WH<br>—<br>—<br>Accessories<br>Cat. no.<br>2 circuits<br>JN2<br>~~O~~<br>~~OE ~~<br>~~ee~~|||<br>=|White (standard)<br>NFT3-WH<br>Black<br>NFT3-BK<br>Accessories<br>Cat. no.<br>2 circuits<br>JN3<br>~~O~~<br> ~~ee~~||
||Marking tape||AT512||MT12-1-2||||MT12-1-2|
||Mounting|C-Rail|NFTA<br>NRA|C-Rail|NFTA<br>NRA|||C-Rail|NFTA<br>NRA|
Dimensions — in (mm) Dimensions — in (mm) Dimensions — in (mm) ~~ee es =e~~
**==> picture [371 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.40<br>(60.96)<br>0.88 (15.44)0.60 (1.78) 0.07 ( 23.80.93 (32.94) 1.29 0) 0.36(9.14) (29.97)1.18 (32.94)1.29<br>(22.35)<br>BRORORERONE ale 1.68 + 1.23 1.23 ieee) |<br>(42.82) (31.34) (31.37)<br>- 7 L<br>1.09<br>(27.68) (16.51)0.65 |<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
10-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Connector products — 10**
**==> picture [399 x 419] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|3-pole|
|||ib|wey|°|)|
|NC3|NSE3|NSS3|
|Approval|Approval|Approval|
|Technical data|Technical data|Technical data|
|Rated voltage|600V|Rated voltage|600V|Rated voltage|600V|
|Rated Current|175A|Rated Current|115A|Rated Current|30A|
|Center spacing in (mm)|1.06 / 26.92|Center spacing in (mm)|1.06 / 26.92|Center spacing in (mm)|0.385 / 9.77|
|Conductor cross-section,|14~2/0 /2.1~67.4|Conductor cross-section,|Ring terminals|Conductor cross-section,|Ring terminals|
|flexible (AWG/mm2)|Cu/AL|flexible (AWG/mm2)|only|flexible (AWG/mm2)|only|
|Number of Poles|3|Number of Poles|3|Number of Poles|3|
|Circuits per foot|11|Circuits per foot|11|Circuits per foot|28|
|Torque(N•m)|5.1|Torque(N•m)|3.6|Torque(N•m)|1.4|
|Torque(lb-in)|45|Torque(lb-in)|32|Torque(lb-in)|12|
|Screw|5/16 - 24|Screw|1/4 - 28|Screw|#6-32|
|WxHxD(mm)|79.4 x 44.5 x 44.5|WxHxD(mm)|79.2 x 38.9 x 445|WxHxD(mm)|31.5 x 33.7 x 31.8|
|Colors|Cat. no.|Colors|Cat. no.|Colors|Cat. no.|
|OO|White (standard)|NC3-WH|Oe|White (standard)|NSE3-WH|White (standard)|NSS3-WH|
|—|—|—|—|—|—|
|Accessories|Cat. no.|Accessories|Cat. no.|Accessories|Cat. no.|
|Ss|a|s|
|—|—|2 circuits|JNSE3|2 circuits|JNSS3|
|MT12-1-2|MT12-1-2|MT12-1-2|
|—|
|Panel mount|—|Panel mount|—|Panel mount|NFTA|
|NFTA|NFTA Series|
|C-Rail|C-Rail|C-Rail|NRA|
|NRA|NRA Series|
|Dimensions — in (mm)|Dimensions — in (mm)|Dimensions — in (mm)|
**----- End of picture text -----**<br>
Dimensions — in (mm) Dimensions — in (mm) ~~SS Le~~
1.25 (31.75) (79.38)3.12 ~~_— ..|~~ (44.45)1.75 ~~.,x»~~ 0.250 x 0.190mtg. slots Sig ~~£.,~~ trata. ~~ha~~ (44.45)1.75 ~~Fo~~ (31.50)1.24 **(44.45)1.75** (31.75)1.25 (33.73)1.32 1.53 (31.75)1.25 0.250 x 0.190"mtg. slots (38.86) 3.12 (79.24)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
10-5
**10 — Connector products**
## DIN-Rail depluggable blocks
Depluggable terminal blocks are available for both 35mm DIN-Rail and C-Rail applications. These blocks provide a simple depluggable* option for panel wiring applications with the convenience of quick, easy, snap-on installation. Product accessories such as jumpers and marking tape are available for most products.
UL E62622
CSA File 15364 15188 PLU3 PLU1 CSA File 47235 (15188 Series) Approval Approval Approval * Not for use as a load break Technical data Technical data Technical data disconnect. Rated voltage 600V Rated voltage 600V Rated voltage 600V Rated Current 30A Rated Current 40A Rated Current 70A Center spacing in (mm) 0.375 / 9.52 Center spacing in (mm) 0.39 / 9.91 Center spacing in (mm) 0.3 / 7.62 Conductor cross-section, flexible (AWG/mm2) 16~12 / 1.3~3.3 Conductor cross-section, flexible (AWG/mm2) 22~8 / 0.3~8.4 Conductor cross-section, flexible (AWG/mm2) 18~4 / 0.8~21.2 Number of Poles 3 or 4 Number of Poles 3 Number of Poles 1 - 3 Circuits per foot 32 Circuits per foot 28 Circuits per foot 19 Torque(N•m) 1.4 Torque(N•m) 2 Torque(N•m) 3.6 Torque(lb-in) 12 Torque(lb-in) 18 Torque(lb-in) 32 Screw #6-32 Screw #8-32 Screw 1/4 - 28 WxHxD(mm) WxHxD(mm) WxHxD(mm) 3-Pole 30.2 x 49.3 x 47.8 3-Pole 31.8 x 47.0 x 45.6 1-Pole 18.5 x 47.0 x 45.6 4-Pole 39.2 x 49.3 x 47.8 2-Pole 34.0 x 47.0 x 45.6 3-Pole 49.5 x 47.0 x 45.6 Colors Cat. no. Colors Cat. no. Colors Cat. no. ~~= PO=~~ e) White (standard) 15188-3 ie) White (standard) PLU3-WH Oo White (1-Pole) PLU1-WH Block White (standard) 15188-4 Black PLU3-BK White (2-Pole) PLU11-WH (25 o ~~e oO.~~ e) White (3-Pole) PLU111-WH Accessories Cat. no. Accessories Cat. no. Accessories Cat. no. ~~pe~~ S ~~eeeeee—C eS~~ Jumper 2 circuits 15188J-2-J, J15188 2 circuits JN3 2 circuits JN1 — — MT12-1-2 MT12-1-2 Marking tape DRL35MMLO NFTA NFTA Mounting 35mm DIN-Rail DRL35MMHI C-Rail (AL) NRA C-Rail (AL) NRA Reverse Wiring 15188-_R Configurable Option LockingReverse; Locking 15188-_RS15188-_S — — — — Options offered for both pole lengths ~~7,~~ Dimensions — in (mm) ~~ee~~ Dimensions — in (mm) Dimensions — in (mm) 3 Pole = 1.19 (30.22) 4 Pole = 1.56 (39.62) 1.85 (46.99) 1.25 1.87 1.48 (31.75) (47.49) (37.59) 1.94 (49.27) 0.59 1.79 (14.98) (45.64) ee IN-LINE WIRING DIRECTION ~~“|~~ ae 3 Pole = 1.19 (30.22)4 Pole = 1.56 (39.62) (31.75)1.25 (31.75)1.25 (46.99)1.85 0.375 0.22 (9.52) (5.58) 1.25 (31.75) 1.94 (49.27) vx eS WY | REVERSE WIRING DIRECTION
Eaton.com/bussmannseries
10-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Connector products — 10**
Panel mount multi-pole blocks
Multi-pole panel mount terminal blocks provide a compact, high density circuit connection solution without the necessity of a mounting rail. These products are designed to be nested together to form one string of circuit connections.
**==> picture [552 x 499] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|blocks provide a compact,|
|high density circuit connection|
|—<|solution without the necessity of|“ey|AS|
|a mounting rail. These products|
|Pe,|a|«Ny|
|are designed to be nested|
|together to form one string of|
|circuit connections.|
|UL E62622|
|CSA 15364|
|PSU1|KT3|KT4|
|Approval|Approval|Approval|
|Technical data|Technical data|Technical data|
|Rated voltage|600V|Rated voltage|600V|Rated voltage|600V|
|Rated Current|45A|Rated Current|40A|Rated Current|30A|
|Center spacing in (mm)|0.625 / 15.88|Center spacing in (mm)|0.39 / 9.91|Center spacing in (mm)|0.25 / 6.35|
|Conductor cross-section, flexible (AWG/mm2)|Ring terminals only|Conductor cross-section, flexible (AWG/mm2)|22~8 / 0.3~8.4|Conductor cross-section, flexible (AWG/mm2)|22~10 / 0.3~5.3|
|Number of Poles|3|Number of Poles|4|
|Number of Poles|1 - 3|
|Circuits per foot|19|Circuits per foot|28|Circuits per foot|48|
|Torque(N•m)|2.7|Torque(N•m)|2|Torque(N•m)|2|
|Torque(lb-in)|24|Torque(lb-in)|18|Torque(lb-in)|18|
|Screw|#10-32|Screw|#8-32|Screw|#6-32|
|WxHxD(mm)|59.5 x 31.8 x 31.0|WxHxD(mm)|43.8 x 34.0 x 32.2|
|WxHxD(mm)|Colors|Cat. no.|Colors|Cat. no.|
|3-Pole|50.3 x 49.1 x 62.1|
|White (standard)|KT3-WH|White|KT4-WH-A*|
|Block|
|Colors|Cat. no.|a|OO|5|White|KT4-WH-B*|
|Accessories|Cat. no.|Accessories|Cat. no.|
|Ss|
|e)|White (3-Pole)|PSU111-WH|Jumper|a|2 circuits|JN3|4 circuits|JN4|
|Accessories|Cat. no.|Marking tape|On|Panel mount|MT12-1-2—|MTC6|
|Panel mount|—|
|—|—|• Mounting foot|KAD|
|Mounting|
|MT12-1-2|Dimensions — in (mm)|Dimensions — in (mm)|
|Se|||
|C-Rail (AL)|NFTA|0.98|0.37|
|NRA|1.87|1.25|0.25|(24.99)|(9.40)|
|(47.63)|(31.75)|(6.35)|
|—|—|(31.04)1.22|(15.88)0.62|(32.23)1.26|
|#8 screw clearance|
|Dimensions — in (mm)|KAD|
|end mtg.|
|adapter|1.25|
|(31.75)|
|(49.12)1.931.93|2.34|1.25|(34.04)1.34|
|0.625|1.48|(59.51)|(31.75)|
**----- End of picture text -----**<br>
**==> picture [100 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
(49.12)1.931.93<br>0.625 1.48<br>(15.88) (37.64)<br>2.44<br>(62.10)<br>1.30<br>0.43 (33.00)<br>(11.10)<br>**----- End of picture text -----**<br>
- The KT4 products are designed to be nested together to form one string of circuit connectors. When used in series, order catalog numbers KT4WH-A and KT4-WH-B.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
10-7
**10 — Connector products**
Panel mount quick-connect blocks
A time saving alternative for electrical connections, the Bussmann series quickconnect terminal blocks offer a convenient solution. With male spade terminals, wire connections are made quickly and simply with these terminal blocks.
UL E62622
CSA 15364
||BNQ21|||BQQ41||
|---|---|---|---|---|---|
||Approval|||Approval||
||Technical data|||Technical data||
||Rated voltage|600V||Rated voltage|600V|
||Rated Current|40A||Rated Current|30A|
||Center spacing in (mm)|0.437 / 11.1||Center spacing in (mm)|0.437 / 11.1|
||Conductor cross-section,<br>flexible (AWG/mm<br>2)|22~8 / 0.3~8.4||Conductor cross-section,<br>flexible (AWG/mm<br>2)|0.25" Quick-connect<br>terminals only|
||Number of Poles|1||Number of Poles|1|
||Circuits per foot|24||Circuits per foot|24|
||Torque(N•m)|2||Torque(N•m)|NA|
||Torque(lb-in)|18||Torque(lb-in)|NA|
||Screw|#8-32||Screw|NA|
||WxHxD(mm)|33.3 x 35.8 x 37.3||WxHxD(mm)|33.3 x 35.8 x 37.3|
||Colors|Cat. no.||Colors|Cat. no.|
|Block|White (standard)<br>BNQ21-WH<br>Accessories<br>Cat. no.<br>—<br>—<br>~~Ps~~<br>~~OO ~~|||White (standard)<br>BQQ41-WH<br>Accessories<br>Cat. no.<br>—<br>—<br>p<br> ~~[nn~~||
||Panel mount|—||Panel mount|—|
|Mounting|• Mounting foot|BQE||• Mounting foot|BQE|
||Dimensions — in (mm)<br>~~Ee~~|||Dimensions — in (mm)<br>~~yyy~~||
**==> picture [258 x 57] intentionally omitted <==**
**----- Start of picture text -----**<br>
(end mtg. adaptor)#BQE #8 mtg.screw (end mtg. adaptor)#BQE #8 mtg.screw<br>0.56 0.56<br>(14.28) (14.28)<br>(37.33)1.47 (37.33)1.47<br>LEEREE BA | (35.81)1.41 c B!See) BA Ca (35.81)1.41<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
10-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Connector products — 10**
C7021 power feed through terminal blocks
Power feed through terminal block with two rows 1/4-20 studs capable of accommodating the industry standard two-hole compression lugs on both studs in parallel.
## Ratings
- Volts 300 V
- Amps 115/175 A* per pole
- 175 achieved using both studs in parallel, 115 A using a single stud per line.
## Agency information
- cURus, Guides XCFR2, XCFR8, File E62622
- CE
## Specifications
- Poles: 1- to 6
- Wire range: AWG #3/0-8
- Center spacing: 0.69" (18mm)
- Bolt hole spacing: 0.625" or 5/8" (16mm)
- Stud: Standard 1/4-20 stud (tin-plated brass) or optional M6 stud.
- Mounting: #6 thread cutting screws (not included) or optional mounting ends.
- Torque: 36 lb-in.
- Operating temperature: 130°C (266°F) max.
## Typical applications
Dimensions — mm (in)
**==> picture [278 x 348] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|D|
|C|(0.62)15.8|(1.10)28.0(0.38)9.6|(2.19)55.7|
|5.4|
|With|(0.21)|
|mounting ends|(0.62)15.8|(0.49)12.5|
|Ø 9.0 TYP|
|‘|f|o|lelcl.|e|e|(0.35)|
|7.9|
|(0.31)|A|1/4-20 UNC-2A|Ø 12.2 TYP|
|Thread TYP|(0.48)|
|B|
|17.5 TYP|
|E|n|(0.69)|e|
|Without|15.0 TYP|
|(0.59)|24.0|
|mounting ends|(0.94)|
|(0.50)12.7|Blind Hole for #6Thread Cutting|
|14.5 TYP|Screw|
|(1.30)33.0|t|(0.57)|—|||14.5 TYP(0.57)|
|E|
|A|14.2|1.6|
|—|( ø.56)|ae|(R.06)|
|Panel cutouts|30.0|
|(1.18)|
|P||Catalog no.|A|B|C|D|E|
|C7021-01-X with mounting ends|
|C7021-02-X|17.5 (0.69)|—|54.4 (2.14)|67.3 (2.65)|31.8 (1.25)|
|C7021-03-X|34.9 (1.37)|—|70.9 (2.83)|84.8 (3.34)|49.2 (1.94)|
|C7021-04-X|52.3 (2.06)|—|89.3 (3.52)|102.2 (4.02)|66.7 (2.63)|
|C7021-05-X|69.8 (2.75)|—|106.8 (4.20)|119.7 (4.71)|84.2 (3.31)|
|C7021-06-X|87.2 (3.44)|—|124.2 (4.89)|134.1 (5.40)|101.7 (4.00)|
|C7021-01N-X without mounting ends|
|C7021-02N-X|17.5 (0.69)|36.1 (1.42)|—|—|31.8 (1.25)|
|C7021-03N-X|34.9 (0.69)|53.5 (2.11)|—|—|49.2 (1.94)|
|C7021-04N-X|52.3 (2.06)|71.0 (2.80)|—|—|66.7 (2.63)|
|C7021-05N-X|69.8 (2.75)|88.4 (3.48)|—|—|84.2 (3.31)|
|C7021-06N-X|87.2 (3.44)|105.9 (4.17)|—|—|101.7 (4.00)|
**----- End of picture text -----**<br>
- Applications requiring up to 175 A utilizing a 2-hole compression lug on 5/8" centers
- Input/output block for telecommunications power panels
- To eliminate busbars
## Catalog number build-a-code
**==> picture [408 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Symbol|Poles|Mount ends|Studs|Hardware|
|C7021|—|
|01 = 1-pole (2 studs)|Blank = Mount ends|Blank = Standard|Blank = No hardware|
|02 = 2-pole (4 studs)|N = No mount ends|M6 = M6 studs|0 = Bulk pack, one set|
|03 = 3-pole (6 studs)|1 = Bulk pack, two sets|
|04 = 4-pole (8 studs)|2 = Assembled, bottom|
|05 = 5-pole (10 studs)|3 = Assembled, top|
|06 = 6-pole (12 studs)|4 = Assembled, both sets|
**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
10-9
**10 — Connector products**
## TB100 double row terminal blocks
## Dimensions — in
## Ratings*
- 300 V
**==> picture [36 x 57] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB100-08<br>TB100-04SP<br>**----- End of picture text -----**<br>
- 30 A
- Breakdown voltage: 3600 V
- Maximum rating shown; some options may be rated lower.
## Agency information
- UL File E62622/CSA File 47235; IEC Compliance
A 0.14 0.14 B (3.5) (3.5) 0.88 0.31 (7.9) (22.3) PES ESS RBs ~¢ URS Fee eS) Fes Fes) Sd ST SISO) 0.375 0.30 0.17 dia. ~~+]~~ fe (9.5) (7.6) ~~|~~ (4.3) 0.41 0.25 (6.3) jf (|) |) | | i} |) |) (10.4) —— _— CEIGSBRR SBE<a
## Specifications
- Poles: 2 to 36
- Center spacing: 0.375" or 3/8" (10mm)
- Wire range: 14-22 AWG Cu
- Screw size: #6-32 phil-slot screws
- Torque rating: 9 lb-in
- Distance between barriers: 0.30" (8mm)
- Mounting: #6 screws
- Operating temperature: -40°C to 130°C (-40°F to 266°F)
## Materials
- Molded black thermoplastic base, UL rated 94V0
- Tin-plated brass terminals
- Zinc-plated steel screws
|Poles<br>A<br>B<br>Poles<br>A<br>B<br>Poles<br>A<br>B<br>~~|~~|Poles<br>A<br>B<br>Poles<br>A<br>B<br>Poles<br>A<br>B<br>~~|~~|Poles<br>A<br>B<br>Poles<br>A<br>B<br>Poles<br>A<br>B<br>~~|~~|
|---|---|---|
|02<br>1.40<br>1.12<br>14<br>5.90<br>5.62<br>26|10.40|10.12|
|03<br>1.78<br>1.50<br>15<br>6.28<br>6.00<br>27|10.78|10.50|
|04<br>2.16<br>1.88<br>16<br>6.66<br>6.38<br>28|11.16|10.88|
|05<br>2.53<br>2.25<br>17<br>7.03<br>6.75<br>29|11.53|11.25|
|06<br>2.90<br>2.62<br>18<br>7.40<br>7.12<br>30|11.90|11.62|
|07<br>3.28<br>3.00<br>19<br>7.78<br>7.50<br>31|12.28|12.00|
|08<br>3.66<br>3.38<br>20<br>8.16<br>7.88<br>32|12.66|12.38|
|09<br>4.03<br>3.75<br>21<br>8.53<br>8.25<br>33|13.03|12.75|
|10<br>4.40<br>4.12<br>22<br>8.90<br>8.62<br>34|13.40|13.12|
|11<br>4.78<br>4.50<br>23<br>9.28<br>9.00<br>35|13.78|13.50|
|12<br>5.16<br>4.88<br>24<br>9.66<br>9.38<br>36|14.16|13.88|
|13<br>5.53<br>5.25<br>25<br>10.03<br>9.75|||
- 1" = 25.4mm.
## Catalog number build-a-code
|Symbol||Poles|Screw options|Marking/cover|Hardware options|
|---|---|---|---|---|---|
|TB100|—|||||
|||02 to 36|Blank = steel phil-slot, zinc-plated<br>00 = screws shipped bulk|L1 to L6<br>Marking options, see page 10-16|QC1 to QC20 = Quick-connects<br>Custom options†<br>~~Po~~|
||||B = brass phil-slot, nickel-plated|Special markings†, see page 10-16|J101 = flat slip-on jumper (2 position only)|
||||SP = steel SEMS phil-slot, zinc-plated||0J2 = over barrier jumpers|
||||||0J4 = over barrier jumpers|
- Contact factory for configuration.
## Accessories
- Marker strips, see page 10-17
- Covers, see page 10-16
Eaton.com/bussmannseries
10-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Connector products — 10**
## Screw options
**==> picture [34 x 38] intentionally omitted <==**
**==> picture [240 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
B SP<br>Brass phil-slot, nickel-plated Steel SEMS phil-slot, zinc-plated<br>F502-J (bulk) B001-7021-J (bulk)<br>**----- End of picture text -----**<br>
## Hardware options
Quick-connects — assembled: 0.187" x 0.020" terminals, 13 amps maximum. For other orientations, contact factory.
**==> picture [521 x 52] intentionally omitted <==**
**==> picture [521 x 181] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC1 QC2 QC3 QC4 QC5 QC6 QC7<br>QC8 QC9 QC10 QC11 QC12 QC13 QC14<br>QC15 QC16 QC17 QC18 QC19 QC20<br>**----- End of picture text -----**<br>
Quick-connects — bulk: minimum order 100 pieces per catalog number.
**==> picture [65 x 36] intentionally omitted <==**
**==> picture [475 x 122] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC101-J QC102-J QC103-J QC104-J QC105-J<br>Flat — none QC 45° — none QC 90° — none Flat — Flat Flat — QC 45°<br>QC106-J QC107-J QC108-J QC109-J<br>Flat — QC 90° QC 45° — QC 45° QC 45° — QC 90° QC 90° — QC90°<br>**----- End of picture text -----**<br>
Jumpers — bulk: minimum order 100 pieces per catalog number. Contact factory for jumper assembly.
**==> picture [65 x 34] intentionally omitted <==**
**==> picture [16 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
J101<br>**----- End of picture text -----**<br>
Flat slip-on (bulk: J101-J)
**==> picture [65 x 57] intentionally omitted <==**
OJ2
Slip-on over barrier (bulk: OJ2-J)
**==> picture [65 x 56] intentionally omitted <==**
OJ4
Closed over barrier (bulk: OJ4-J)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
10-11
**10 — Connector products**
## TB200 and TB200HB double row terminal blocks
## Ratings*
- Volts
**==> picture [155 x 79] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB200-10SP<br> • 300 V (TB200)<br> • 600 V (TB200HB) ;<br> • Amps 30 A<br> • Breakdown voltage 4800 V<br>TB200HB-06<br>* Maximum rating shown; some<br>options may be rated lower.<br>**----- End of picture text -----**<br>
## Agency information
- UL File E62622, CSA File 47235 and 15364; IEC Compliance
## Specifications
- Poles: 2 to 30
- Wire range: 12 - 22 AWG Cu
- Center spacing: 0.437" or 7/16" (11mm)
- Distance between barriers: 0.353" (9mm)
- Screw size: #6-32 phil-slot screws
- Torque rating: 9 lb-in
- Mounting: #6 screws
- Operating temperature: -40°C to 130°C (-40°F to 266°F)
## Materials
- Molded black thermoplastic base UL rated 94V0
- Terminal plating: Tin-plated brass terminals
- Zinc-plated steel screws
## Dimensions — in
**==> picture [263 x 394] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|A|
|0.16|0.16|
|B|
|(4.0)|(4.0)|
|TB200|0.44 (11.2)|1.12|
|(28.4)|
|>|l|0.437|e|0.35|a|3|e|,|
|(11.1)|(8.9)|
|0.17 dia.|
|(4.3)|
|0.56|
|0.31 (7.8)|(14.2)|
|er|OE|(|
|{|
|A|
|0.16|0.16|
|(4.0)|B|(4.0)|
|;(—|—|
|0.44 (11.2)|(22.8)0.90|(34.8)1.37|
|| gigisielelisipigiata|
|TB200HB|0.437|0.353|
|0.17 dia.|a|aa|(11.1)|(8.9)||||e|0.17 x 0.22 slots|
|(4.3)|(4.3 x 5.6)|
|an|
|0.75|
|0.33 (8.4)|(19.0)|
|deeeeeeeEEE|[Gl|
|tT|TT|
|Poles|A|B|Poles|A|B|Poles|A|B|
|PO|
|02|1.63|1.31|12|6.00|5.68|22|10.37|10.06|
|03|2.07|1.75|13|6.44|6.12|23|10.81|10.50|
|04|2.51|2.18|14|6.87|6.56|24|11.25|10.93|
|05|2.94|2.62|15|7.31|7.00|25|11.68|11.37|
|06|3.38|3.06|16|7.75|7.43|26|12.12|11.81|
|07|3.82|3.50|17|8.19|7.87|27|12.56|12.25|
|08|4.25|3.93|18|8.62|8.31|28|13.00|12.68|
|09|4.69|4.37|19|9.06|8.75|29|13.44|13.12|
|10|5.13|4.81|20|9.50|9.18|30|13.87|13.56|
|11|5.57|5.25|21|9.94|9.62|
**----- End of picture text -----**<br>
- 1" = 25.4mm.
## Catalog number build-a-code
**==> picture [514 x 170] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Barrier|
|Symbol|style|Poles|Screw options|Marking/cover|Hardware options|
|TB|—|
|200 =|02 to 30|Blank = Steel phil-slot, zinc-plated|L1 to L6 = Marking options,|QC1 to QC20 = Quick-connects|
|Standard|see page 10-16|
|200HB =|00 = Screws shipped bulk|Special markings|[†]|, see page|Custom options|[†]|
|High barrier|10-16|
|B = Brass phil-slot, nickel-plated|J201 = Flat slip-on jumper, 2 position|
|only|
|BS = Brass SEMS phil-slot, nickel-|0J3 = Over barrier jumpers|
|plated|
|P = Steel SEMS (P-style)|0J5 = Over barrier jumpers|
|SP = Steel SEMS phil-slot, zinc-plated|0J7 = Over barrier jumpers|
|SS = Stainless steel SEMS, phil-slot|
|ST = Stainless steel, phil-slot|
**----- End of picture text -----**<br>
† Contact factory for configuration.
## Accessories
- Marker strips, see page 10-17
- Covers, see page 10-16
Eaton.com/bussmannseries
10-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Connector products — 10**
Screw options
**==> picture [34 x 38] intentionally omitted <==**
**==> picture [33 x 38] intentionally omitted <==**
**==> picture [33 x 38] intentionally omitted <==**
**==> picture [33 x 38] intentionally omitted <==**
**==> picture [512 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
B BS SP P ST SS<br>Brass phil-slot Brass SEMS phil-slot Steel SEMS phil-slot Steel SEMS Stainless steel phil- Stainless steel SEMS<br>nickel-plated nickel-plated zinc-plated (P-style) slot phil-slot<br>B001-7016-J (bulk) B001-7019-J (bulk) B001-7007-J (bulk) B001-7000-J (bulk) F507-J (bulk) B001-7085-J (bulk)<br>**----- End of picture text -----**<br>
## Hardware options
Quick-connects — assembled: 0.25" x 0.031" terminals, 20 amps maximum. For other orientations, contact factory.
**==> picture [521 x 53] intentionally omitted <==**
**==> picture [520 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC1 QC2 QC3 QC4 QC5 QC6 QC7<br>QC8 QC9 QC11 QC10 QC12 QC13 QC14<br>QC15 QC16 QC17 QC18 QC19 QC20<br>**----- End of picture text -----**<br>
Quick-connects — bulk: minimum order 100 pieces per catalog number.
**==> picture [65 x 35] intentionally omitted <==**
**==> picture [479 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC201-J QC202-J QC203-J QC204-J QC205-J<br>QC 45° — blank Flat — blank QC 90° — blank Flat — Flat Flat — QC 45°<br>QC206-J QC207-J QC208-J QC209-J<br>Flat — QC 90° QC 45° — QC 45° QC 45° — QC 90° QC 90° — QC 90°<br>**----- End of picture text -----**<br>
Jumpers — bulk: minimum. order 100 pieces per catalog number. Contact factory for jumper assembly.
**==> picture [65 x 35] intentionally omitted <==**
**==> picture [65 x 57] intentionally omitted <==**
**==> picture [65 x 57] intentionally omitted <==**
**==> picture [66 x 57] intentionally omitted <==**
**==> picture [499 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
J201 OJ3 OJ5 OJ7<br>Flat slip-on Slip-on over barrier for TB200HB Closed over barrier for TB200HB Closed over barrier for TB200<br>(not available on TB200HB) OJ3-J (bulk) OJ5-J (bulk) OJ7-J (bulk)<br>J201-J (bulk)<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
10-13
**10 — Connector products**
TB300 and TB345 double row terminal blocks
Dimensions — in
## Ratings*
|Ratings*|||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Ratings*||||||||||8-32 binding head screw - TB 300|||||||||||
|||||||||||10-32 binding head screw - TB 345|||||||||||
|• Volts 600 V|||||||||||A||||||||||
|• Amps|TB300-08|||||0.22<br>(5.6)|||||B||||||||||
|• 30 A (TB300)<br>• 45 A (TB345)<br>• Breakdown voltage 7500 V<br>* Maximum rating shown; some|TB345-06SP<br>bd,<br>a<br>fh.<br>et|||TB300<br>and<br>TB345|0.56<br>(14.2)<br>0.56<br>(14.2)<br>0.412<br>(10.4)<br>0.21dia.<br>0.21 x 0.25 slots<br>(5.3 x 6.3)<br>1.33<br>(33.8)<br>0.90<br>(22.8)<br>0.50 (12.7)<br>~~eae~~<br>—, {3 oacf)es 8 (2)fc)<br>3)<br>g**e**<br>rell||||||||||||||||
|options may be rated lower.|||||(5.3)|||||||||||on|||||
|Agency information|||||0.33 (8.4)||||||||||||0.81<br>(20.5)||||
|UL File E62622, CSA File 47235; IEC Compliance||||||7|||||||||||||||
|Specifications||||Poles|A|B|||Poles||A|B|Poles||||A||B||
|• Poles: 2 to 24||||02|2.13|1.69|||10||6.62|6.19|18||||11.12||10.68||
|• Wire range: 8 - 22 AWG Cu||||03|2.69|2.25|||11||7.18|6.75|19||||11.68||11.25||
|• Center spacing: 0.562" or 9/16" (14mm)||||04|3.25|2.81|||12||7.75|7.31|20||||12.24||11.81||
|• Screw size||||05|3.81|3.37|||13||8.31|7.87|21||||12.80||12.37||
|• TB300 — #8-32 phil-slot screws<br>• TB345 — #10-32 phil-slot screws<br>• Torque rating||||06<br>07<br>08<br>09|4.37<br>4.94<br>5.50<br>6.06|3.94<br>4.50<br>5.06<br>5.62|||14<br>15<br>16<br>17||8.87<br>9.43<br>9.99<br>10.56|8.44<br>9.00<br>9.56<br>10.12|22<br>23<br>24||||13.37<br>13.93<br>14.49||12.93<br>13.50<br>14.06||
- #8 screws - 16 lb-in
- 1" = 25.4mm.
- #10 screws - 20 lb-in
- Distance between barriers: 0.41" (10mm)
- Mounting
- TB300 — #8 screws
- TB345 — #10 screws
- Operating temperature: -40°C to 130°C (-40°F to 266°F)
## Materials
- Molded black thermoplastic base, UL rated 94V0
- Tin-plated brass terminals
- Zinc-plated steel screws
## Catalog number build-a-code
|Symbol|Screw size||Poles|Screw options|Marking/cover|Hardware options|
|---|---|---|---|---|---|---|
|TB||—|||||
||300 = 8-32 screw<br>345 = 10-32 screw||02 to 24|Blank = Steel phil-slot, zinc-plated<br>00 = Screws shipped bulk|L1 to L6 marking options, see page<br>10-16<br>Special markings†, see page 10-16|QC1 to QC20 = Quick-connects (TB300<br>only)<br>Custom options (TB300 only)†|
|||||B = Brass phil-slot, nickel-plated||J301 = Flat slip-on jumper|
|||||BS = Brass SEMS phil-slot, nick-||OJ6 = Over barrier jumper|
|||||el-plated (TB300 only)|||
|||||SP = Steel SEMS phil-slot, zinc-plat-||OJ11 = Over barrier jumper|
|||||ed|||
|||||ST = Stainless steel, phil-slot|||
† Contact factory for configuration.
## Accessories
- Marker strips, see page 10-17
- Covers, see page 10-16
Eaton.com/bussmannseries
10-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Connector products — 10**
## Screw options
**==> picture [34 x 38] intentionally omitted <==**
**==> picture [33 x 38] intentionally omitted <==**
**==> picture [436 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
B BS SP ST<br>Brass SEMS phil-slot nickel-plated Steel SEMS phil-slot zinc-plated Stainless steel phil-slot<br>- B001-7015-J (TB300 bulk) - B001-7017-J (TB300 bulk) - B001-7063-J (TB300 bulk)<br>- B001-5774-J (TB346 bulk) - B001-7064-J (TB345 bulk)<br>**----- End of picture text -----**<br>
**==> picture [89 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
Brass phil-slot nickel-plated<br>- B001-7018-J (TB300 bulk)<br>- B500-023-028-J (TB345 bulk)<br>**----- End of picture text -----**<br>
## Hardware options
Quick-connects — assembled: TB300 only; 0.25" x 0.031" terminals, 20 amps maximum. For other orientations, contact factory.
**==> picture [521 x 53] intentionally omitted <==**
**==> picture [521 x 163] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC1 QC2 QC3 QC4 QC5 QC6 QC7<br>QC8 QC9 QC10 QC11 QC12 QC13 QC14<br>QC15 QC16 QC17 QC18 QC19 QC20<br>**----- End of picture text -----**<br>
Quick-connects — bulk: *TB300 only; minimum order 100 pieces per catalog number.
**==> picture [65 x 35] intentionally omitted <==**
**==> picture [476 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
QC201-J QC202-J QC203-J QC204-J QC205-J<br>Flat — blank QC 45° — blank QC 90° — blank Flat — Flat Flat — QC 45°<br>QC206-J QC207-J QC208-J QC209-J<br>Flat — QC 90° QC 45° — QC 45° QC 45° — QC 90° QC 90° — QC 90°<br>**----- End of picture text -----**<br>
Jumpers — bulk: TB300 only; minimum order 100 pieces per catalog number. Contact factory for jumper assembly.
**==> picture [65 x 35] intentionally omitted <==**
J301 Flat slip-on J301-J (bulk)
**==> picture [65 x 57] intentionally omitted <==**
OJ6
Closed over barrier OJ6-J (bulk)
**==> picture [65 x 56] intentionally omitted <==**
OJ11
Slip-on over barrier OJ11-J (bulk)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
10-15
**10 — Connector products**
Marking options and covers for double row terminal blocks
## Standard marking
**==> picture [229 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3 3 2 1<br>L1 L2 L3<br>L4 L5 L6<br>1 2 3<br>3 2 1 1 2 3 3 2 1<br>**----- End of picture text -----**<br>
Standard markings are applied directly to the side(s) of a block. The standard marking color is white. The standard numeral height is 0.125 inches (3mm).
## Special marking*
**==> picture [263 x 111] intentionally omitted <==**
Special markings are available at an additional charge. Drawing(s) must be submitted to ensure accuracy of part required. Consult factory for price and delivery.
* Not available on TB400 products
Note: Blocks marked on both sides require a different code for each side. Example: Style L1 on one side of the block requires Style L2 on the other side to ensure common terminal marking. To order, add appropriate suffix (L1, L2, L3, L4, L5 and/or L6) to block catalog number in the proper sequence.
## Covers
(must be ordered separately)
**==> picture [129 x 90] intentionally omitted <==**
**==> picture [263 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog no. For block family<br>**----- End of picture text -----**<br>
||DD1-J|TB100|
|---|---|---|
||DD2-J|TB200|
||DD2HB-J|TB200HB|
||DD3-J|TB300|
Covers prevent personnel, screws and foreign items from contacting live terminals, and are available in white (opaque) or clear plastic. Two cover clips are supplied with each cover. The cover width is 1.31 inches (33mm). Example: 10 position cover, white, TB100 = catalog number X12010.
## Cover catalog number build-a-code[†]
**==> picture [264 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
High barrier<br>Symbol Cover strip [†] Poles option only<br>**----- End of picture text -----**<br>
|||||
|---|---|---|---|
|X||||
|119 = TB100 - clear<br>02 to 36 (TB100)<br>HB = High<br>barrier††<br>120 = TB100 - white<br>02 to 30 (TB200/<br>TB200HB)<br>219 = TB200/TB200HB - clear<br>02 to 24 (TB300/<br>TB345)<br>220 = TB200/TB200HB - white<br>319 = TB300/TB345 - clear<br>320 = TB300/TB345 - white||||
† Cover strip not available for TB400 products.
†† Applicable to X219 and X220 only.
Cover clips — bulk
Eaton.com/bussmannseries
10-16
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Connector products — 10**
## Top marker strips
(order separately from blocks)
**==> picture [148 x 91] intentionally omitted <==**
Top mounting marker strips must be ordered separately and are only available in white (opaque) plastic. Two cover clips are supplied with each marker strip.
Example: 12 position cover, TB200, 0.032" x 0.312" = catalog number X20312.
Example: 12 position cover, TB200HB, 0.06" x 0.50" = catalog number X23312HB.
Top marker strip catalog number build-a-code
**==> picture [265 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
High barrier<br>Series Top marker strip [†] Poles option only<br>**----- End of picture text -----**<br>
|||||
|---|---|---|---|
|X||||
|103 = TB100<br>(0.032 thk x 0.312 w)<br>02 to 36<br>(TB100)<br>HB = High<br>barrier††<br>133 = TB100<br>(0.060 thk x 0.500 w)<br>02 to 30<br>(TB200/TB200HB)<br>203 = TB200/TB200HB<br>(0.032 thk x 0.312 w)<br>02 to 24<br>(TB300/TB345)<br>233 = TB200/TB200HB<br>(0.060 thk x 0.500 w)||||
303 = TB300/TB345 (0.032 thk x 0.380 w)
333 = TB300/TB345 (0.060 thk x 0.500 w)
† Marking strips not available for TB400 products
†† Applicable to X203 and X233 only.
## Bottom marker strips
(order separately from blocks)
**==> picture [288 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
Marking two sides<br>Marking two sides<br>Marking one side<br>Connector products<br>**----- End of picture text -----**<br>
Bottom mounting marker strips are made of 0.03" thick black PVC. Space is available along the edge to handle most marking needs. All marker strips must be ordered separately.
To order, specify catalog number and required marking orientation. Example: 13 position strip, TB100 with no markings, space for marking one side = catalog number X10513. Consult factory for specials.
Standard numeral height is 0.125". Standard markings are 0-99. Special markings are available on special order. Drawing(s) must be submitted to ensure accuracy of part required.
## Dimensions — in
||Dim.|TB100|TB200|For TB<br>TB200HB|block<br>TB300|TB345|TB400|
|---|---|---|---|---|---|---|---|
||A|1.13|1.37|1.62|1.58|1.58|N/A|
||B|1.38|1.62|1.81|1.81|1.81|N/A|
Bottom marker strip catalog number build-a-code
**==> picture [263 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
Marking<br>Symbol Bottom Marker Strip [†] Poles orientation<br>X<br>**----- End of picture text -----**<br>
|X||||
|---|---|---|---|
|101 = TB100<br>marking both sides<br>02 to 36<br>(TB100)<br>BF =<br>Bottom forward<br>105 = TB100<br>marking one side<br>02 to 30<br>(TB200/TB200HB)<br>BR =<br>Bottom reverse<br>201 = TB200<br>marking both sides<br>02 to 24<br>(TB300/TB345)<br>TF =<br>Top forward<br>205 = TB200<br>marking one side<br>TR =<br>Top reverse<br>291 = TB200HB<br>marking both sides<br>295 = TB200HB<br>marking one side<br>301 = TB300 and TB345<br>marking both sides<br>305 = TB300 and TB345<br>marking one side||||
† Not available for TB400 products.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
10-17
**10 — Connector products** TOI
## TB400 double row terminal blocks
## Ratings
- Volts 600 V
- Amps 75 A
- Breakdown voltage 7500 V
**==> picture [29 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB400-05<br>**----- End of picture text -----**<br>
## Agency information
- UL File E62622, CSA File 47235; IEC Compliance
## Specifications
- Poles: 2 to 12
- Wire range: 6-14 AWG Cu
- Center spacing: 0.687" or 11/16" (17mm)
- Distance between barriers: 0.56" (14mm)
- Screw size: #10-32 phil-slot screws
- Torque rating: 20 lb-in
- Mounting: #10 screws
- Operating temperature: -40°C to 130°C (-40°F to 266°F)
## Materials
- Molded black thermoplastic base, UL rated 94V0
- Tin-plated brass terminals
**==> picture [66 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in<br>**----- End of picture text -----**<br>
|A||
|---|---|
|B||
|0.15 dia.<br>(3.8)<br>0.68~~7~~<br>(17.4)<br>0.22<br>(5.6)<br>0.625<br>(15.9)<br>1.12<br>(28.4)<br>0.687<br>(17.4)<br>0.562<br>(14.3)<br>1.81<br>(46.0)<br>0.76<br>(19.3)<br>0.46 (11.7)<br>1.34<br>(34.0)<br>0.22 dia. (5.6)<br>~~er~~<br>~~we~~<br>“CRB ~~S~~r~~-~~<br>~~|~~<br>|||
|Poles<br>A<br>B<br>Poles<br>A<br>B<br>Poles<br>A<br>B<br>~~|~~||
|02<br>2.51<br>2.06<br>06<br>5.26<br>4.81<br>10<br>8.01<br>7.56||
|03<br>3.20<br>2.75<br>07<br>5.95<br>5.50<br>11<br>8.70<br>8.25||
|04<br>3.89<br>3.44<br>08<br>6.64<br>6.19<br>12<br>9.39<br>8.94||
|05<br>4.58<br>4.13<br>09<br>7.33<br>6.88||
- 1" = 25.4mm.
## Screw options
- Zinc-plated steel screws
**==> picture [225 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Brass nickel-plated phil-slot Stainless steel phil-slot<br>B500-023-028-J (bulk) B001-7064-J (bulk)<br>**----- End of picture text -----**<br>
## Hardware options
**==> picture [92 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
OJ14: Closed over barrier<br>OJ14-J (bulk)<br>**----- End of picture text -----**<br>
Catalog number build-a-code
Symbol Poles Screw options TB400 — ~~EE—E—E—_E__~~ 02 to 12 Blank = Zinc-plated steel phil-slot 00 = Screws shipped bulk B = Nickel-plated brass phil-slot ST = Stainless steel, phil-slot
## Accessories
- OJ14 - Jumper over barrier, consult factory for pole configuration
Eaton.com/bussmannseries
10-18
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Connector products — 10**
## KU double row terminal blocks
## Ratings
**==> picture [62 x 59] intentionally omitted <==**
**----- Start of picture text -----**<br>
KU_<br>KU_SC<br>**----- End of picture text -----**<br>
- Volts 600 V
- Amps 60 A*
- 60 A rating achieved with 6 AWG Cu wire crimped to ring terminal.
## Agency information
- UL File E62622, CSA File 47235
## Dimensions — in
**==> picture [279 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
KUX B<br>0.62<br>KU only (15.9)<br>Poles A B A<br>02 2.50 1.62 2.00<br>2.00 1.50<br>04 3.75 2.87 3.25 (50.8) (38.1)<br>06 5.00 4.12 4.50<br>08 6.25 5.37 5.75<br>10 7.50 6.62 7.00 #10 screwclearance 0.43 1 .2 5<br>12 8.75 7.87 8.25 (11.1 ) (31.8)<br>0.50<br>1" = 25.4mm. (12.7)<br>A<br>Connector products<br>**----- End of picture text -----**<br>
## Specifications
- Poles: 2 to 12
## Accessories (order separately)
- Wire range: 6-22 AWG Cu
- Center spacing: 0.625" (16mm)
- Screw size: #10-32
- Torque rating: 20 lb-in
- Distance between barriers: 0.437" (11mm)
- Mounting: Panel mount
MTMU(poles) NUM(poles) JU12 Molded marking Molded marking Jumper, 12 circuits tape, matte finish tape
- Operating temperature: 105°C (221°F) max.
## Materials
- Molded black Noryl base, UL rated 94V1
- Terminal plating: Nickel-plated brass terminals
- Zinc-plated steel screws
NUE NUC(poles) End piece for NUC Cover
## Catalog number build-a-code - KU versions
|Symbol / for|Poles||Screw options|Covers|Marking strip|
|---|---|---|---|---|---|
|||—||||
|KU / Standard block|2||00 = Screws shipped bulk|WC = Top cover and2 end|MT = Matte finish|
||4|||plates||
||6|||||
|KUX / Short block|8||BP = Brass phil-slot, nickel-plated||NU = Numbered 1 to|
||10||||12, horizontal|
|KURL / Standard w/removable link|12||P = Steel screw w/pressure plate zinc-plated||NUV = Numbered 1 to|
||||||12, vertical|
|KUXRL / Short block w/removable link|||W = Brass washer head, nickel-plated||PT = Marker strip for|
||||||cover†|
## Catalog number build-a-code - KU__SC versions
|Symbol / for|Poles||Screw options|Covers|Marking strip|
|---|---|---|---|---|---|
|||—||||
|KUSC / Standard w/shorting strap and 4|2||00 = Screws shipped bulk|WC = Top cover and 2|PT = Marker strip for|
|shorting screws|4|||end plates|cover†|
||6|||||
|KUXSC / Short block w/shorting strap|8||BP = Brass phil-slot, nickel-plated|||
|and 4 shorting screws|10|||||
||12||P = Steel screw w/pressure plate, zinc-plated|||
- P = Steel screw w/pressure plate, zinc-plated
W = Brass washer head, nickel-plated
† Requires WC cover option
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
10-19
**10 — Connector products**
## End brackets
**==> picture [83 x 121] intentionally omitted <==**
**----- Start of picture text -----**<br>
BRKT-ND<br>7<br>4 eee.<br>:<br>Use with DRL35MMHI<br>DRL35MMLO<br>**----- End of picture text -----**<br>
**==> picture [74 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — mm<br>**----- End of picture text -----**<br>
**==> picture [82 x 121] intentionally omitted <==**
**----- Start of picture text -----**<br>
BRKT-NDSCRW<br>i P<br>i SS<br>Use with DRL35MMHI<br>DRL35MMLO<br>**----- End of picture text -----**<br>
**==> picture [73 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — mm<br>**----- End of picture text -----**<br>
**==> picture [215 x 121] intentionally omitted <==**
**----- Start of picture text -----**<br>
BRKT-NDSCRW2 BRKT-NDSCRW3<br>ésC_ a &<br>P Sey Rein<br>Use with DRL35MMHI Use with DRL35MMHI<br>DRL35MMLO DRL35MMLO<br>**----- End of picture text -----**<br>
**==> picture [74 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — mm<br>**----- End of picture text -----**<br>
**==> picture [74 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — mm<br>**----- End of picture text -----**<br>
## Mounting rails and brackets
**==> picture [176 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
DRL35MMLO* DRL35MMHI*<br>Low profile High profile<br>35mm DIN-Rail 35mm DIN-Rail<br>**----- End of picture text -----**<br>
**==> picture [36 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
BRKT-ANGL<br>Angle bracket<br>**----- End of picture text -----**<br>
**==> picture [30 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
BRKT-FLT<br>Flat bracket<br>**----- End of picture text -----**<br>
**==> picture [23 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
NFTA**<br>C-Rail<br>**----- End of picture text -----**<br>
**==> picture [20 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
NRA**<br>C-Rail<br>**----- End of picture text -----**<br>
- Available in 1 meter lengths only.
- ** Cut-to-length. Consult your Bussmann series product representative for details.
Eaton.com/bussmannseries
10-20
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
## **Disconnect switches — 11**
## **The power of space**
The Bussmann[TM] series Compact Circuit Protector for Class CF CUBEFuse[TM]
## Contents
|Description|Section<br>page|
|---|---|
|Compact Circuit Protector disconnect switches||
|Class CF CUBEFuse up to 100 A (CCP2-CF)|2-8|
|Class CF CUBEFuse 200 and 400 A (CCP2-CF)|9-12|
|Accessories for CUBEFuse CCP2|13-|
|Multi-wire lug kits|13-14|
|Selector and pistol handles, shafts, NFPA 79 compliant<br>handles|15-16|
|Flange handle rod and cable operators|17|
|200 and 400 A switch rotary mechanisms|18|
|Auxiliary contacts|19-20|
|PLC fuse monitors (up to 100 A switches)|21-22|
|How to order Class CF switches|23-35|
|Switches up to 100 A|23-30|
|200 and 400 A switches|32-35|
|Description<br>Compact Circuit Protector disconnect switches|Section<br>page||||
|---|---|---|---|---|
|Compact Circuit Protector Base (CCP2B - CUBEFuse)|36-37||||
|Class CC, UL supplemental and IEC 10x38 (CCP2)|38-42||||
|Accessories for Class CC, UL supp. and IEC 10x38 CCP2|43-47||||
|Multi-wire lug kits<br>Selector and pistol handles, shafts, NFPA 79 compliant<br>handles<br>Auxiliary contacts<br>PLC fuse monitors<br>How to order Class CC, UL supplemental and IEC 10x38<br>switches|43<br>44<br>45<br>46-47<br>48-51||Disconnect|switches|
|Low profile Class CC and G, UL supplemental and<br>IEC 10x38 (CCPLP)<br>52-53<br>UL 98 fused disconnect switches, 30 to 800 A<br>~~ee~~|||||
|Introduction and agency information<br>54<br>Product line summary — UL<br>55<br>30 A Class CC and compact Class J<br>56-57<br>30 A standard Class J<br>58-59<br>60 A compact Class J<br>60-61<br>~~TTT~~CS<br>~~TT~~<br>~~TT I TT SS~~<br>~~gC~~|||||
|60 A standard Class J<br>62-63<br>100 A standard Class J<br>64-65<br>200 A and 400 A standard Class J<br>66-68<br>600 A standard Class J and 800 A Class L<br>69-70<br>UL 98 non-fused disconnect switches, 30 to 1200 A<br>~~eee~~<br>~~OO~~<br>~~JT~~|||||
|Introduction, agency information and IEC product summary<br>71<br>UL product summary<br>72<br>30 A, 60 A and 100 A compact<br>73-74<br>~~TN~~|||||
|100 A, 200 A and 400 A standard|75-76||||
|600 A, 800 A, 1000 A and 1200 A standard|77-78||||
|UL 508 non-fused disconnect switches, 16 to 80 A|||||
|Introduction, agency information and IEC product summary|79||||
|UL product summary|80||||
|16 A, 25 A, 40 A, 63 A and 80 A|81-83||||
|Enclosed UL 98 and UL 508 disconnect switches|||||
|Introduction and agency information|84||||
|Fused UL 98 enclosed disconnects, 30 to 800 A|85-86||||
|Non-fused UL 98 enclosed disconnects, 30 to 1200 A|87-88||||
|Non-fused UL 508 enclosed disconnects, 16 to 80 A|89-90||||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-1
**11 — Disconnect switches**
## Compact Circuit Protector
UL 98 Class CF disconnect switches from 30 to 400 A
CCP2 switch up to 100 A with and without rotary operation mechanisms
200 A CCP2 switch with and without rotary operation mechanisms
## Class CF CCP contents
## Section page
**==> picture [255 x 508] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|30, 60 and 100 amp switches|
|Descriptions and specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4|
|Catalog numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5|
|Terminal data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-8|
|200 and 400 A switches|
|Descriptions and specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|9-10|
|Catalog numbers and horsepower ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|10|
|Available lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|10|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12|
|Accessories|
|Multi-wire lug kits|
|30, 60 and 100 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|13|
|200 and 400 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|14|
|Handles and shafts|
|Selector and pistol handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|15|
|Handle shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|16|
|NFPA 79 compliant handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|16|
|Flange handle rod and cable operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|17|
|200 and 400 A switches|
|Front rotary mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|18|
|Side rotary mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|18|
|Terminal shroud kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|18|
|Phase barrier kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|18|
|Handle extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|18|
|Auxiliary contacts|
|30, 60 and 100 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|19|
|200 and 400 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|20|
|PLC fuse monitor (30, 60 and 100 A switches) . . . . . . . . . . . . . . . . . . . . . . . . . 21-22|
|How to order|
|30 and 60 A switches|
|Switch only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|23|
|Front and right side rotary switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25|
|Left side rotary switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|26|
|100 A switches|
|Switch only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|27|
|Front and right side rotary switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-29|
|Left side rotary switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|30|
|200 and 400 A switches|
|200 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33|
|400 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-35|
**----- End of picture text -----**<br>
400 A CCP2 switch with and without rotary operation mechanisms
Eaton.com/bussmannseries
11-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
Catalog symbols for 30, 60 and 100 A switches
**==> picture [264 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Symbol Description<br>**----- End of picture text -----**<br>
|CCP2-(pole)-(amps)CF|Switch only|
|---|---|
|CCP2R-(pole)-(amps)CF|Right front rotary, clockwise operated switch|
|CCP2RL-(pole)-(amps)CF|Left front rotary,clockwise operated switch|
|CCP2S-(pole)-(amps)CF|Right side rotary,clockwise operated switch|
|CCP2SL-(pole)-(amps)CF|Left side rotary, counterclockwise operated<br>switch|
## Description
The revolutionary, next generation Bussmann™ series Compact Circuit Protector (cat. no. CCP2) is a fused UL[®] 98 branch circuit disconnect switch utilizing the UL Class CF time-delay or fast-acting CUBEFuse™ with Class J electrical performance. With up to a 51 percent smaller footprint than a traditional fusible solution, these switches provide a high 200 kA SCCR to help improve panel and assembly SCCR.
The 35 mm DIN-Rail mount CCP2 is available in a variety of 30, 60 and 100 amp configurations to meet many application needs including rotary operation.
The switch-only versions of the 30, 60 and 100 A disconnects are direct, drop-in replacements for the earlier models (noted by a catalog number starting “CCP-”). The auxiliary contacts and PLC remote fuse indicator are backwards compatible. The multi-wire lug kits and terminal shrouds are not.
Application flexibility is extended with an optional multi-wire lug kit, featuring finger-safe shrouds, that provides three (30 and 60 A switches) and six (100 A switches) additional wire ports on each pole for power distribution applications.
Other accessories include a PLC fuse monitor for open fuse indication and NO/NC auxiliary contacts that easily integrate into various monitoring systems.
Front and side rotary operated versions are easily applied for through-the-door or through the left or right side operation to enhance safety.
## Ratings
- Volts
- 347 Vac (1-pole switches)
- 600 Vac (2- and 3-pole switches)
- 125 Vdc*
- • Amps • 30 A
- 60 A
- 100 A
## Conductors/ terminals
- 75°C Cu, see conductor tables for size, type and torque information
- Box lug, single/dual conductor
- Fork terminal suitable for line, load or accessory connection, max. 30 A suitable for use with:
- 10-24 screw for 30 and 60 A switches
- 1/4-28 screw for 100 A switches
- Multi-wire lug kits — see accessories for details
Storage and operating temperature
- -20°C to 75°C (-4°F to 167°F)*
- For fuse performance under or above 25°C, consult fuse performance derating charts in the Bussmann Division publication no. 3002, titled Selecting Protective Devices (SPD)
Lockout/ tagout provisions
- 1/4” lock, direct use on switches without rotary mechanisms requires a lock with a straight shank of sufficient length to engage all poles
Miniumum enclosure size per UL 98*
- 30 and 60 A switch 10”x 8”x 6”(254 x 203 x 152 mm)
- 100 A switch, 12” x 10” x 6” (305 x 254 x 152 mm)
- Smaller enclosures may be used at the discretion of the user, with adherence to NEC minimum wire bend radius requirements.
## Mounting**
- 35 mm DIN-Rail
- ** Switch is panel mount with flange handle cable operator.
Local open fuse indication minimum voltage
- 90 Vac, requires an open fuse to be in the CCP2 and the switch in the ON position
## Accessories
- Multi-wire lug kits with terminal shrouds
- Selector and pistol handles for use with rotary operated switches
- 8 mm shafts for use with selector and pistol handles
- Auxiliary contacts
- PLC fuse monitor
- NFPA 79 compliant handle
- Flange handle rod and cable operators
- Hot stick handles
- SCCR
- 200 kA RMS Sym.
- 100 kA DC
## Poles
- 1-, 2- and 3-poles catalog number dependent
- Switch amp rating and installed fuse amp rating dependent, see catalog number table for details.
## Agency information
- UL 98 Listed, Guide WHTY, File E302370
- cULus to Canadian Standard 22.2 No. 4-04, Guide WHTY7, File E302370
- RoHS compliant
- CE
- IEC 60947-3 AC-21A (up to 30A)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-3
**11 — Disconnect switches**
## Features
- Uses UL Class CF time-delay or fast-acting CUBEFuse with Class J electrical performance
- Extremely compact design at 25.4 mm (1 inch) wide per pole
- Amp rating rejection disconnects will not accept a CUBEFuse amp rating greater than switch rating
- High 200 kA short-circuit current rating
- Disconnect rated to provide means for load isolation
- Full voltage rated at 347 Vac (1-pole switches) and 600 Vac (2- and 3-pole switches)
- 125 Vdc* rated to meet specialized applications
- UL 98 Listed and suitable for branch circuit disconnect and branch circuit protection with installed fuses
- Horsepower rated
- Open fuse indication:
- Local open fuse indication light standard on each pole
- Optional PLC fuse monitor for wired remote open fuse indication by signaling a PLC and opening a contactor to de-energize all phases, if required
- Additional open fuse indication can be provided by the indicating time-delay CUBEFuse (6 to 100 A)
- Finger-safe construction with 10 AWG (6 mm[2] ) wire or larger
- Built-in switch interlock prohibits removing or installing the fuse while in the ON position
- Padlockable for lockout/tagout procedures with a 1/4” lock
Right front rotary operated CCP2 switch with PLC fuse monitor.
- Rotary operated versions provide for through-the-door and through-the-side operation flexibility and enhanced safety with:
- Right or left front operation
- Right or left side operation
- Optional selector and pistol handles, and shafts available for use with rotary operated versions
Rotary operating versions
> • Multi-wire lug kits with terminal shrouds allow for power distribution to multiple loads. Each lug has three (30 and 60 A switches) or six (100 A switches) ports rated for single and dual wires (see lug kits in accessories for details).
- Switch amp rating and installed fuse amp rating dependent, see catalog number table for details.
Switch handle (ganged on 2- and 3-pole versions)
**==> picture [259 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
Open fuse<br>indicating light<br>Fuse holder<br>Fork terminal<br>Box lug terminal<br>1/4” Lockout/ yo I be<br>tagout provision<br>**----- End of picture text -----**<br>
Left front Right front Uses clockwise handles Uses clockwise handles Left side Right side Uses counterclockwise handles Uses clockwise handles
Eaton.com/bussmannseries
11-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
30, 60 and 100 A switch catalog numbers
|30, 60 and 100 A switch catalog numbers|||
|---|---|---|
|Catalogno.<br>Poles<br>Description/switch operation|Volts<br>SCCR|Max Hprating(Vac)<br>120<br>240<br>480<br>600<br>1-1/2<br>—<br>—<br>—<br>—<br>3<br>—<br>—<br>—<br>5<br>15<br>10|
|30 ampswitches|||
|CCP2-1-30CF<br>1<br>Switch only<br>CCP2-2-30CF<br>2<br>CCP2-3-30CF<br>3|347 Vac/125 Vdc<br>200 kA AC<br>100 kA DC<br>600 Vac/125 Vdc<br>600 Vac<br>600 Vac/125 Vdc<br>600 Vac<br>600 Vac/125 Vdc<br>600 Vac<br>600 Vac/125 Vdc<br>600 Vac<br>600 Vac/125 Vdc<br>600 Vac||
|CCP2R-2-30CF<br>2<br>Right front rotary, clockwise<br>CCP2R-3-30CF<br>3||Disconnect<br>switches<br>—<br>3<br>—<br>—<br>—<br>5<br>15<br>10<br>—<br>3<br>—<br>—<br>—<br>5<br>15<br>10<br>—<br>3<br>—<br>—<br>—<br>5<br>15<br>10|
|CCP2RL-2-30CF<br>2<br>Left front rotary, clockwise<br>CCP2RL-3-30CF<br>3|||
|CCP2S-2-30CF<br>2<br>Right side rotary, clockwise<br>CCP2S-3-30CF<br>3|||
|CCP2SL-2-30CF<br>2<br>Left side rotary, counterclockwise<br>CCP2SL-3-30CF<br>3||—<br>3<br>—<br>—<br>—<br>5<br>15<br>10<br>3<br>—<br>—<br>—<br>—<br>7-1/2<br>—<br>—<br>—<br>7-1/2<br>20<br>10<br>—<br>7-1/2<br>—<br>—<br>—<br>7-1/2<br>20<br>10<br>—<br>7-1/2<br>—<br>—<br>—<br>7-1/2<br>20<br>10<br>—<br>7-1/2<br>—<br>—<br>—<br>7-1/2<br>20<br>10<br>—<br>7-1/2<br>—<br>—<br>—<br>7-1/2<br>20<br>10<br>5<br>—<br>—<br>—<br>—<br>10<br>—<br>—<br>—<br>20<br>50<br>40<br>—<br>10<br>—<br>—<br>—<br>20<br>50<br>40<br>—<br>10<br>—<br>—<br>—<br>20<br>50<br>40<br>—<br>10<br>—<br>—<br>—<br>20<br>50<br>40<br>—<br>10<br>—<br>—<br>—<br>20<br>50<br>40|
|60 ampswitches|||
|CCP2-1-60CF<br>1<br>Switch only<br>CCP2-2-60CF<br>2<br>CCP2-3-60CF<br>3|347 Vac/125 Vdc*<br>200 kA AC<br>100 kA DC<br>600 Vac/125 Vdc*<br>600 Vac<br>600 Vac/125 Vdc*<br>600 Vac<br>600 Vac/125 Vdc*<br>600 Vac<br>600 Vac/125 Vdc*<br>600 Vac<br>600 Vac/125 Vdc*<br>600 Vac||
|CCP2R-2-60CF<br>2<br>Right front rotary, clockwise<br>CCP2R-3-60CF<br>3|||
|CCP2RL-2-60CF<br>2<br>Left front rotary, clockwise<br>CCP2RL-3-60CF<br>3|||
|CCP2S-2-60CF<br>2<br>Right side rotary, clockwise<br>CCP2S-3-60CF<br>3|||
|CCP2SL-2-60CF<br>2<br>Left side rotary, counterclockwise<br>CCP2SL-3-60CF<br>3|||
|100 ampswitches|||
|CCP2-1-100CF<br>1<br>Switch only<br>CCP2-2-100CF<br>2<br>CCP2-3-100CF<br>3|347 Vac/125 Vdc**<br>200 kA AC<br>100 kA DC<br>600 Vac/125 Vdc**<br>600 Vac<br>600 Vac/125 Vdc**<br>600 Vac<br>600 Vac/125 Vdc**<br>600 Vac<br>600 Vac/125 Vdc**<br>600 Vac<br>600 Vac/125 Vdc**<br>600 Vac||
|CCP2R-2-100CF<br>2<br>Right front rotary, clockwise<br>CCP2R-3-100CF<br>3|||
|CCP2RL-2-100CF<br>2<br>Left front rotary, clockwise<br>CCP2RL-3-100CF<br>3|||
|CCP2S-2-100CF<br>2<br>Right side rotary, clockwise<br>CCP2S-3-100CF<br>3|||
|CCP2SL-2-100CF<br>2<br>Left side rotary, counterclockwise<br>CCP2SL-3-100CF<br>3|||
* 125 Vdc for installed fuse amp ratings up to 40 A. 24 Vdc for installed fuse amp ratings from 45 to 60 A.
- ** 125 Vdc for installed fuse amp ratings up to 80 A, 24 Vdc for installed fuse amp ratings from 90 to 100 A.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-5
## **11 — Disconnect switches**
Box lug terminal conductor data
|Wire<br>type<br>AWG<br>range<br>Class<br>30 and 60 A switches|Wire<br>type<br>AWG<br>range<br>Class<br>30 and 60 A switches|Wire<br>type<br>AWG<br>range<br>Class<br>30 and 60 A switches|Quantity|Torque<br>N•m (lb-in)|
|---|---|---|---|---|
|75°C Cu<br>4-6<br>8-18<br>6-8<br>10-18<br>10-18<br>4-18<br>6-18<br>4-18<br>6-18<br>100 A switches|4-6<br>8-18<br>6-8|Stranded, Class B<br>to K<br>Stranded, Class B/C|Single<br>Dual|3.95 (35)<br>2.26 (20)<br>3.39 (30)|
|||Stranded, Class K||2.26 (20)|
||10-18|Stranded, Class B<br>to K|||
||10-18|Solid|Single/dual|2.26 (20)|
||4-18|Stranded, UL ferrule,<br>Class B/C|Single|3.39 (30)|
||6-18||Twin†||
||4-18|Stranded, UL ferrule,<br>Class K|Single|2.82 (25)|
||||Twin†||
|75°C Cu|12-18|Stranded, Class B/C|Single|2.26 (20)|
||10|||2.82 (25)|
||8<br>|||4.52 (40<br>|
||4-6<br>1-3|||5.08 (45)<br>6.21 (55)|
||4-12||Dual|5.08 (45)|
||12-18|Stranded, UL ferrule,<br>Class B/C|Single|2.26 (20)|
||10<br>1-8<br>10-18|||3.95 (35)<br>4.52 (40)<br>2.26 (20)|
||6-9<br>10-18|Solid|Twin†<br>Single/Dual|<br>2.82 (25)<br>2.26 (20)|
||8-18|Class K|Single|2.26 (20)|
||1-7|||3.39 (30)|
||3-10||Dual|5.08 (45)|
||8-18|Class K, UL ferrule|Single|2.26 (20)|
||1-7|||3.39 (30)|
||6-18||Twin|2.26 (20)|
- Two stranded conductors placed in one UL Listed twin ferrule.
## Lineside and loadside fork terminal
- Fork terminal suitable for line, load or accessory connection, max. 30 A suitable for use with:
## Dimensions – mm (in)
Switch (shown with optional terminal shrouds)
**==> picture [263 x 246] intentionally omitted <==**
**----- Start of picture text -----**<br>
114<br>4.5 206<br>8.1<br>76<br>3.0<br>83<br>50 75<br>3.3<br>2.0 3.0<br>25<br>1.0 30A Fuse<br>75 89<br>3.0 3.5<br>60A Fuse<br>**----- End of picture text -----**<br>
30 and 60 amp switches
**==> picture [263 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
75<br>3.0<br>50<br>2.0<br>25 148<br>1.0 5.8<br>240<br>9.5<br>100<br>3.9<br>**----- End of picture text -----**<br>
100 amp switches
- 10-24 screw for 30 and 60 A switches
- 1/4-28 screw for 100 A switches
## Available Bussmann series fuses
|UL fuse<br>class|Type/description<br>Volts<br>Data<br>sheet<br>no.|
|---|---|
|CF|Indicating time-delay, Low-Peak™<br>CUBEFuse (6-100 A)<br>600 Vac/<br>300 Vdc<br>9000<br>Non-indicating time-delay, Low-Peak<br>CUBEFuse (1-100 A)|
||Non-indicating fast-acting CUBEFuse<br>(1-100 A)<br>600 Vac/dc<br>2147|
Eaton.com/bussmannseries
11-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
Left front rotary switches (shown with optional terminal shrouds)
**==> picture [263 x 262] intentionally omitted <==**
**----- Start of picture text -----**<br>
114<br>4.5 206<br>8.1<br>99<br>83<br>3.9<br>101 3.3<br>4.0<br>76<br>3.0 30 A Fuse<br>99<br>3.9 89<br>3.5<br>60 A Fuse<br>**----- End of picture text -----**<br>
Right front rotary switches (shown with optional terminal shrouds)
**==> picture [263 x 279] intentionally omitted <==**
**----- Start of picture text -----**<br>
114<br>4.5 206<br>8.1<br>99<br>83<br>3.9<br>101 3.3<br>4.0<br>76<br>3.0 30 A Fuse<br>99<br>89<br>3.9<br>3.5<br>60 A Fuse<br>**----- End of picture text -----**<br>
30 and 60 amp switches
**==> picture [263 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
101<br>4.0<br>76 148<br>3.0 5.8 240<br>9.5<br>100 106<br>3.9 4.2<br>**----- End of picture text -----**<br>
100 amp switches
**==> picture [263 x 178] intentionally omitted <==**
**----- Start of picture text -----**<br>
101<br>4.0<br>148<br>3.076 5.8 240<br>9.5<br>100 106<br>3.9 4.2<br>**----- End of picture text -----**<br>
100 amp switches
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-7
## **11 — Disconnect switches**
Left side rotary switches (shown with optional terminal shrouds)
**==> picture [263 x 245] intentionally omitted <==**
**----- Start of picture text -----**<br>
114<br>4.5<br>206<br>8.1<br>83<br>75 3.3<br>3.0<br>101<br>4.0 30 A Fuse<br>89<br>75 3.5<br>3.0<br>60 A Fuse<br>**----- End of picture text -----**<br>
30 and 60 amp switches
**==> picture [263 x 179] intentionally omitted <==**
**----- Start of picture text -----**<br>
101<br>4.0<br>148<br>76 5.8<br>240<br>3.0<br>9.5<br>100<br>3.9<br>**----- End of picture text -----**<br>
100 amp switches
Right side rotary switches (shown with optional terminal shrouds)
**==> picture [258 x 246] intentionally omitted <==**
**----- Start of picture text -----**<br>
114<br>4.5 206<br>8.1<br>83<br>75 3.3<br>101 3.0<br>4.0<br>76<br>30 A Fuse<br>3.0<br>75 89<br>3.0 3.5<br>60 A Fuse<br>**----- End of picture text -----**<br>
30 and 60 amp switches
**==> picture [256 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
101<br>4.0<br>76 148<br>3.0 5.8 240<br>9.5<br>100<br>3.9<br>**----- End of picture text -----**<br>
100 amp switches
Eaton.com/bussmannseries
11-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
200 and 400 A switches
## Poles
- 1-, 2- and 3-poles catalog number dependent
Agency information
- UL 98 Listed, Guide WHTY, File E302370
- cULus to Canadian Standard 22.2 No. 4-04, Guide WHTY7, File E302370
- RoHS compliant
Conductors/terminals
**==> picture [178 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
200 A switch 400 A switch<br>**----- End of picture text -----**<br>
- See available lug table for size, type and torque information
Storage and operating temperature
- -20°C to 75°C (-4°F to 167°F)*
- For fuse performance under or above 25°C, consult fuse performance derating charts in the Bussmann Division publication no. 3002, titled Selecting Protective Devices (SPD)
Lockout/tagout provisions using 1/4” lock
- Integral with switch handle
**==> picture [93 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
With side rotary accessory<br>**----- End of picture text -----**<br>
With front rotary accessory
|Catalog no.|Poles|Amps<br>Description|
|---|---|---|
|CCP2-1-200CF|1||
|CCP2-2-200CF|2|200|
|CCP2-3-200CF|3||
|CCP2-1-400CF|1|Switch only|
|CCP2-2-400CF|2|400|
|CCP2-3-400CF|3||
## Description
The Bussmann series 200 and 400 A Compact Circuit Protector (CCP2) fused disconnect switches utilize the finger-safe UL Class CF time-delay CUBEFuse with Class J electrical performance. With up to a 69 percent smaller footprint than a traditional fusible solution, these switches provide a high 200 kA SCCR to help improve panel and assembly SCCR.
The panel mount 200 and 400 A CCP2 switches are available with a variety of accessories to meet many application needs including rotary and flange handle operation.
Rotary operators are available for front or side (right or left) operation. Front rotary operators are for three-pole switches only while the side operator may be applied to the right or left side of 1-, 2- and 3-pole units.
- Front rotary operating mechanism
- Rotary pistol handles
- Flange rod and cable operators
- Minimum enclosure size
- 200 A switch 16 x 12 x 6” (405 x 305 x 150 mm)
- 400 A switch 24 x 16 x 8 (610 x 405 x 200 mm)
- Mounting
- Panel mount
Local open fuse indication minimum voltage
> • 90 Vac, requires an open fuse to be in the CCP2 and the switch in the ON position
## Accessories
- Lugs and lug kits with terminal shrouds
- Pistol handles for use with rotary operated switches
- NFPA 79 compliant handle
- 12 mm shafts for use with selector and pistol handles
- Auxiliary contacts
- Flange handle rod and cable operators
Other accessories include lugs, terminal shrouds, rotary pistol handles, flange rod and cable operating mechanisms, NO/NC auxiliary contacts that easily integrate into various monitoring systems and a handle extension.
Front and side rotary operated versions are easily applied for through-the-door or through the left or right side operation to enhance safety.
## Ratings
- Volts
- 347 Vac (1-pole) 600 Vac (2- and 3-pole)
- Amps
- 200 A
- 400 A
- SCCR
- 200 kA RMS Sym.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-9
**11 — Disconnect switches**
## Features
- Uses UL Class CF time-delay CUBEFuse with Class J electrical performance
- Amp rating rejection feature will not accept a CUBEFuse amp ratings greater than switch rating
- High 200 kA short-circuit current rating
- Disconnect rated to provide means for load isolation
- Full voltage rated at 600 Vac
- UL 98 Listed and suitable for branch circuit disconnect and branch circuit protection with installed fuses
- Horsepower rated (see table below)
- Standard local open fuse indication light on each pole speeds troubleshooting
- Built-in switch interlock prevents inserting or removing fuse while in the ON position
- Padlockable for lockout/tagout procedures with a 1/4” lock
- Front and side rotary operator accessories provide for throughthe-door and through-the-side operation flexibility and enhanced safety
- Optional pistol handles and shafts available for use with rotary operator accessories
- Multi-wire lug kits with terminal shrouds allow for power distribution to multiple loads.
Catalog numbers and horsepower ratings
|Catalogno.<br>Poles<br>Description|Volts AC<br>SCCR|Max Hp rating (Vac)|
|---|---|---|
|||240<br>480<br>600|
|200 ampswitches|||
|CCP2-1-200CF<br>1<br>Switch only<br>CCP2-2-200CF<br>2<br>CCP2-3-200CF<br>3|347<br>200 kA<br>600|—<br>—<br>—|
|||10<br>—<br>—|
|||50<br>100<br>150|
|400 ampswitches|||
|CCP2-1-400CF<br>1<br>Switch only<br>CCP2-2-400CF<br>2<br>CCP2-3-400CF<br>3|347<br>200 kA<br>600|—<br>—<br>—|
|||—<br>—<br>—|
|||100<br>200<br>250|
Available lugs, conductor ratings and terminal torques
|Catalog no.<br>Description<br>Lugs per<br>cat. no.<br>Wire range<br>AWG (mm2)<br>Wire type/<br>temp.<br>Conductor torque<br>N•m (lb-in)<br>Lug mounting screw<br>torque N•m (lb-in)|Catalog no.<br>Description<br>Lugs per<br>cat. no.<br>Wire range<br>AWG (mm2)<br>Wire type/<br>temp.<br>Conductor torque<br>N•m (lb-in)<br>Lug mounting screw<br>torque N•m (lb-in)|
|---|---|
|200 A switches||
|CCP2-L2-1<br>Stainless steel lug<br>1<br>350-4(185-25)<br>Cu 75°C<br>20.3(180)<br>0.9(8)||
|CCP2-L2-1A<br>Aluminum lug*<br>1<br>350-4(185-25)<br>Cu/Al 75°C<br>28.2(250)<br>13.5(120)||
|CCP2-MW2-3<br>3-port multi-wire terminal with shroud*<br>3<br>2-14(35-2.5)<br>Cu/Al 75°C<br>7.9(70)<br>10.8(95)||
|CCP2-MW2-6<br>6-port multi-wire terminal with shroud*<br>3<br>6-14(16-2.5)<br>Cu/Al 75°C<br>2.8(25)<br>10.8(95)||
|* These lugs also accept 1/4”quick connect control wire terminals. Order catalognumber CCP2-CWK2 (package of 12 terminals).||
|400 A Switches||
|CCP2-L4-1<br>Stainless steel lug<br>1<br>500-3(240-35)<br>Cu 75°C|42.0(375)<br>22.0 (200)<br>42.0(375)<br>57.0(500)<br>62.0(550)<br>42.0(375)<br>42.0(375)<br>10-14 = 3.9 (35)<br>8 = 4.5(40)<br>4-6 = 5.0(45<br>1/0-2 = 5.6(50)|
|CCP2-L4-1A<br>Aluminum lug<br>1<br>500-3(240-35)<br>Cu/Al 75°C||
|CCP2-L4B-3<br>Stainless steel lugkit with shroud<br>3<br>750-500(400-240)<br>Cu 75°C||
|CCP2-L4B-3A<br>Aluminum lugkit with shroud<br>3<br>750-500(400-240)<br>Cu/Al 75°C||
|CCP2-L6-3<br>2-port stainless steel lugkit with shroud<br>3<br>(2)500-2(240-35)<br>Cu 75°C||
|CCP2-L6-3A<br>2-port aluminum lugkit with shroud<br>3<br>(2)500-2(240-25)<br>Cu/Al 75°C||
|CCP2-MW6-6<br>6-port multi-wire terminal with shroud<br>3<br>1/0-14 (50-2.5)<br>Cu/Al 75°C||
## Accessories
**==> picture [264 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
Switch<br>Catalog no. amps Description<br>**----- End of picture text -----**<br>
|CCP2-TS2-3<br>200<br>CCP2-PB2<br>CCP2-RM2|3-pole terminal shroud|
|---|---|
||Phase barriers (pack of 2)|
||Front rotaryoperator* (3-pole switch only)|
|CCP2-TS6-3<br>400<br>CCP2-PB6<br>CCP2-RM4|3-pole terminal shroud|
||Phase barriers (pack of 2)|
||Front rotaryoperator* (3-pole switch only)|
|CCP2-SM<br>200/400|Side rotaryoperator* (1-, 2- or 3-pole switches)|
* Complete installation requires pistol handle and shaft, order separately.
Eaton.com/bussmannseries
11-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
200 amp switch dimensions — mm (in)
**==> picture [561 x 604] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø 5.0 (0.2) Thru<br>Ø 9.2 (0.4) 5.4 (0.2) 133.2 (5.2)<br>119.7 (4.7) 160.4 (6.3) 104.7 (4.1)<br>85.4 (3.4) 34.9 (1.4) 34.9 (1.4)<br>55.2 56.0<br>(2.2) (2.2)<br>152.4<br>177.9 (6.0)139.7<br>(7.0) Front rotary (5.5) Side rotary<br>mechanism mechanism<br>accessory accessory<br>CCP2-RM2 CCP2-SM<br>34.9 (1.4) 34.9 (1.4)<br>119.7<br>(4.7)<br>87.3<br>(3.4)<br>335.9<br>(13.2) 3-pole terminal<br>shroud accessory<br>CCP2-TS2-3<br>104.8<br>(4.1)<br>switches<br>Disconnect<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-11
## **11 — Disconnect switches**
400 amp switch dimensions — mm (in)
**==> picture [539 x 268] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø 5.0 (0.2) Thru<br>Ø 14.0 (0.5) 5.9 (0.2)<br>159.3 (6.3)<br>132.8 (5.2) 175.8 (6.9)<br>130.8 (5.1)<br>102 (4.0)<br>43.6 (1.7) 43.6 (1.7)<br>98.8 56.0<br>(3.9) (2.2)<br>225.0<br>(8.8) 214.4<br>257 (8.4)<br>(10.1) Front rotary Side rotary<br>mechanism mechanism<br>accessory accessory<br>CCP2-RM4 CCP2-SM<br>43.6 (1.7) 43.6 (1.7)<br>**----- End of picture text -----**<br>
**==> picture [537 x 299] intentionally omitted <==**
**----- Start of picture text -----**<br>
132.9<br>(5.2)<br>101.4<br>(4.0)<br>(14.3) 365.0 3-pole terminal<br>shroud accessory<br>CCP2-TS6-3<br>139.2<br>(5.4)<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
11-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## 30, 60 and 100 A switch multi-wire lug kits
Installed on CCP2-3-xx
## Catalog numbers
- CCP2-MW1-3 (30 and 60 A switches only)
- CCP2-MW1-6 (100 A switches only)
## Description
The multi-wire lug kits permit expanding each box lug terminal on the switch into a three-port (30 and 60 A switches) or six-port (100 A switches) terminal for power distribution applications.
Each multi-wire lug kit comes with three lugs and three terminal shrouds. Shrouds provide finger-safe protection when properly installed.
Lugs may be mounted on either the loadside or lineside to meet various application needs.
Ports on any one lug accept any conductor combination listed, e.g., one of the ports may have dual 14 AWG wires and the other two ports single 10 AWG wires.
## Ratings
- Volts 600 V
- Amps
- 60 A max (CCP2-MW1-3)
Multi-wire lugs mount in switch box lug terminals to provide three additional wire ports per pole. Lugs can be mounted on the switch lineside or loadside. Each multi-wire lug kit comes with three lugs and three shrouds.
Wire insulation strip lengths
- 100 A max (CCP2-MW1-6)
- SCCR 200 kA
Agency information
- UL Recognized, Guide WHTY2, File E302370
- RoHS compliant
## Storage and operating temperature
1/8” Allen 1/8” Allen head screw head screw EE 1 = 11/16” EF, 1 = 11/16” 2 = 1-1/8” .QJ aeO 2 = 1-1/8” 3 = 1-9/16” 3 = 1-9/16”
- -20°C to 75°C (-4°F to 167°F)
Multi-wire lug conductor information
- 75°C Cu/AL
- AWG size and quantity per port - see table below
|Type|AWG<br>range|Class|Quantity|Torque<br>N•m (lb-in)|
|---|---|---|---|---|
|Cu/Al|4-6<br>8|Stranded, Class B/C|Single|3.95 (35)<br>2.82 (25)|
||10-14|Stranded, Class B/C|Single/dual*|2.26 (20)|
|Cu|10-14<br>Solid<br>Single<br>2.26 (20)<br>8<br>2.82 (25)<br>~~ee~~||||
||10-14|UL ferrule, Class B to K|Single/twin†|2.26 (20)|
Strip back wire insulation to the lengths as indicated in the illustration above and the table below.
|Lug port<br>Strip wire insulation back (inch)|Lug port<br>Strip wire insulation back (inch)|Strip wire insulation back (inch)|
|---|---|---|
||1|11/16|
||2|1-1/8|
||3|1-9/16|
* Dual wire to be same size and type.
- Two stranded conductors placed in one UL Listed twin ferrule.
CCP2 box lug torque for multi-wire lugs
- 30/60 A switch lug, 4.52 N•m (40 lb-in)
- 100 A switch lug, 5.09 N•m (45 lb-in)
Wiring versatility is provided by single/dual rated box lug terminals on the switch, or by the three-port or six-port multi-wire lug kits that are also single/dual wire rated.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-13
**11 — Disconnect switches**
## 200 and 400 A switch multi-wire lug kits
## Catalog numbers
- CCP2-MW2-3 ( 3-port, 200 A switches only)
- CCP2-MW2-6 (6-port, 200 A switches only)
- CCP2-MW6-6 (6-port, 400 A switches only)
## Description
The multi-wire lug kits permit expanding the terminal on the switch into a three-port (200 A switches) or six-port (200 and 400 A switches) terminal for power distribution applications.
Each multi-wire lug kit comes with three lugs and a 3-pole terminal shroud. The shroud provides finger-safe protection when properly installed.
Lugs can only be mounted on loadside to meet application needs.
Ports on any one lug accept any conductor combination listed, e.g., one of the ports may have dual 14 AWG wires and the other two ports single 10 AWG wires.
## Ratings
- Volts 600 V
- Amps
- 225 A max (CCP2-MW2-3 and CCP2-MW2-6)
- 600 A max (CCP2-MW6-6)
- SCCR 200 kA
## Agency information
- UL Recognized, Guide WHTY2, File E302370
- RoHS compliant
## Storage and operating temperature
- -20°C to 75°C (-4°F to 167°F)
Multi-wire lug conductor information
## Installed on CCP2-3-xx
**==> picture [127 x 97] intentionally omitted <==**
## 3- and 6-port multi-wire lugs mounted on 200 A switches
**==> picture [162 x 142] intentionally omitted <==**
## 6-port multi-wire lugs mounted on 400 A switches
Multi-wire lugs mount on the switch terminals to provide three or six additional wire ports per pole. Lugs to be mounted only on the loadside. Each multi-wire lug kit comes with three lugs, a shroud and mounting hardware.
Wire insulation strip lengths
- 75°C Cu/AL
- AWG size and quantity per port - see table below
**==> picture [263 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
AWG Torque<br>Type range Class Quantity N•m (lb-in)<br>**----- End of picture text -----**<br>
|Cu/Al|4-6<br>Stranded, Class B/C<br>Single<br>8|
|---|---|
|Cu|10-14<br>Stranded, Class B/C<br>Single/dual*|
||10-14<br>Solid<br>Single|
||8<br>UL ferrule, Class B to K<br>Single/twin†<br>10-14|
* Dual wire to be same size and type.
- Two stranded conductors placed in one UL Listed twin ferrule.
**==> picture [256 x 57] intentionally omitted <==**
**----- Start of picture text -----**<br>
Straight blade<br>head screw<br>4 mm Allen 4 mm Allen<br>head screw head screw 1 = 3/4 to 7/8”<br>1 = 3/8 to 1/2” 1 = 3/8 to 1/2” 2 = 1-3/8 to 1-1/2”<br>2 = 3/4 to 7/8” 2 = 3/4 to 7/8” 3 = 2 to 2-1/8”<br>3 = 1-1/4 to 1-3/8” 3 = 1-1/4 to 1-3/8”<br>CCP2-MW2-3 CCP2-MW2-6 CCP2-MW6-6<br>**----- End of picture text -----**<br>
Strip back wire insulation to the lengths indicated in the illustration above and the table below.
||Lug kit|Wire<br>Lug port 1|insulation strip length (inch)<br>Lug port 2<br>Lug port 3|insulation strip length (inch)<br>Lug port 2<br>Lug port 3|
|---|---|---|---|---|
||CCP2-MW2-3|3/8 to 1/2|3/4 to 7/8|1-1/4 to 1-3/8|
||CCP2-MW2-6||||
||CCP2-MW6-6|3/4 to 7/8|1-3/8 to 1-1/2|2 to 2-1/8|
Eaton.com/bussmannseries
11-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
Selector handles Pistol handles —short and long
## Selector and pistol handles
Catalog symbol
- CCP2-H4X-_1 (selector handle for 30, 60 and 100 A switches)
- CCP2-H4X-_2 (pistol handle for 30, 60 and 100 A switches)
- CCP2-H4X-_3 (short pistol handle for 200 and 400 A switches)
- CCP2-H4X-_4 (long pistol handle for 200 and 400 A switches)
## Description
Selector and pistol handles are used with rotary operated switches. Pistol handles for 200 and 400 A switches come in short and long versions. All handles are available in black/gray and red/yellow colors, and clockwise/counterclockwise operating modes. Front and right side operated switches use clockwise handles while left side operated switches use counterclockwise handles.
- Agency information • UL Listed, Guide DIHS/DIHS7, File E140305
- Type 1, 4X and 12
- RoHS compliant
- CE
Installation requires an 8 mm shaft for 30, 60 and 100 A switches and a 12 mm shaft for 200 and 400 A switches (ordered separately).
Each handle is rated Type 1, 4X and 12, and accepts up to three (3) 1/4” diameter shank locks for lockout/tagout in the OFF position. They can also be field configured for lock-on and are defeatable.
## Storage and operating temperature
- -20°C to 75°C (-4°F to 167°F)
Only the clockwise operating handles in combination with front rotary operating switches provide a door interlock means to ensure the enclosure door remains shut during lockout/tagout or lock-on. Rotary handles mounted on the enclosure’s left or right side do NOT provide a door interlock means.
See the catalog number table below for applicable rotary switch, handle and shaft combinations.
Handles and shafts for 30, 60 and 100 A switches
|For catalogno.<br>Description/operation<br>Order handle cat. no.<br>Order either 8 mm shaft cat. no.<br>~~ee~~|For catalogno.<br>Description/operation<br>Order handle cat. no.<br>Order either 8 mm shaft cat. no.<br>~~ee~~|For catalogno.<br>Description/operation<br>Order handle cat. no.<br>Order either 8 mm shaft cat. no.<br>~~ee~~|For catalogno.<br>Description/operation<br>Order handle cat. no.<br>Order either 8 mm shaft cat. no.<br>~~ee~~|
|---|---|---|---|
|CCP2R-(pole)-30CF||||
|CCP2R-(pole)-60CF|Right front rotary, clockwise|||
|CCP2R-(pole)-100CF||CCP2-H4X-B1 (selector, black/grey)||
|CCP2RL-(pole)-30CF<br>CCP2RL-(pole)-60CF<br>CCP2RL-(pole)-100CF|Left front rotary, clockwise|CCP2-H4X-R1(selector, red/yellow)<br>CCP2-H4X-B2 (pistol, black/grey)||
|CCP2S-(pole)-30CF<br>CCP2S-(pole)-60CF|Right side rotary, clockwise|CCP2-H4X-R2 (pistol, red/yellow)|CCP2-SH1-290 (11.5”/290 mm)<br>CCP2-SH1-490 (19.3”/490 mm)|
|CCP2S-(pole)-100CF||||
|CCP2SL-(pole)-30CF||CCP2-H4X-B1L (selector, black/grey)||
|CCP2SL-(pole)-60CF|Left side rotary,<br>counterclockwise|CCP2-H4X-R1L (selector, red/yellow)<br>CCP2-H4X-B2L (pistol, black/grey)||
|CCP2SL-(pole)-100CF||CCP2-H4X-R2L (pistol, red/yellow)||
Handles and shafts for 200 and 400 A switches
|For catalogno.|Order front<br>rotary<br>mechanism<br>cat. no.<br>Order right/<br>left side rotary<br>mechanism<br>cat. no.|Order front/right side clockwise<br>handle cat. no.|Order left side counterclockwise<br>handles (use only with CCP2-SM)<br>cat. no.|Order either 12<br>mm shaft cat.<br>no.|
|---|---|---|---|---|
|CCP2-(poles)-200CF|CCP2-RM2*|CCP2-H4X-B3 (short - black/grey)|CCP2-H4X-B3L (short - black/grey)|CCP2-SH2-225|
||CCP2-SM|CCP2-H4X-R3 (short - red/yellow)|CCP2-H4X-R3L (short - red/yellow)|(8.9”/225 mm)|
|CCP2-(poles)-400CF|CCP2-RM4*|CCP2-H4X-B4 (long - black/grey)<br>CCP2-H4X-R4 (long - red/yellow)|CCP2-H4X-B4L (long - black/grey)<br>CCP2-H4X-R4L (long - red/yellow)|CCP2-SH2-425<br>(16.7”/425 mm)|
* For three-pole switches only.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-15
**11 — Disconnect switches** TON
Handle dimensions — mm (in) Selector for 8 mm shafts
**==> picture [257 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
28 Ø7<br>(1.1) (0.3)<br>85 71<br>(3.3) (2.8)<br>48 (1.9) 85 (3.3) 71 (2.8)<br>73 (2.9)<br>26 (1.0)<br>**----- End of picture text -----**<br>
## Handle shafts
8 mm shafts
Short pistol for 8 mm and 12 mm shafts
**==> picture [257 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
33<br>(1.3) 85<br>(3.3)<br>_—<br>Ø7<br>ON (0.3)<br>OFF<br>129<br>(5.1)<br>71<br>(2.8)<br>69 (2.7)<br>96 (3.8) 85 (3.3) 71 (2.8)<br>27 (1.1)<br>**----- End of picture text -----**<br>
12 mm shafts
## Catalog numbers
Long pistol for 12 mm shafts
**==> picture [256 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
34 85<br>(1.3) (3.3)<br>Ø7<br>(0.3)<br>68<br>(2.7) (3.8)96 (3.3)85 (2.8)71<br>28<br>(1.1) 179<br>(7.0) 71<br>(2.8)<br>**----- End of picture text -----**<br>
- CCP2-SH1-290 (8 mm, 290 mm long)
- CCP2-SH1-490 (8 mm, 490 mm long)
- CCP2-SH2-225 (12 mm, 225 mm long)
- CCP2-SH2-425 (12 mm, 425 mm long)
## Description
Square shafts available in:
- 8 mm square by 290 and 490 mm lengths for 30, 60 and 100 A switches
- 12 mm square by 225 and 425 mm lengths for 200 and 400 A switches
All shafts are indexed to ensure handle/switch orientation for correct operation. Shafts are to be cut to length when installed.
## Hot stick handles
## Catalog numbers
## NFPA 79 compliant handles
## Catalog numbers
- CCP2-NFPA-1 (8 mm shafts for 30-100 A switches)
- CCP2-NFPA-2 (12 mm shafts for 200 and 400 A switches)
## Description
NFPA 79 handles mount on the shaft of front rotary operated switch installations and provide a lockout means independent of the door position.
- CCP2-HSHS-94 (94 mm shaft)
- CCP2-HSHL-290 (290 mm shaft)
## Description
The hot stick handle attaches directly to a CCP2 disconnect switch (up to 100 A) with a metal shaft and two lock pins, allowing operation of the switch from ground level with the use of a hot stick device (not included) in applications such as an elevated tap-off box disconnect switch in a data center.
This UL Recognized device is field installable with the CCP2 and is Lockout/Tagout compatible.
Eaton.com/bussmannseries
11-16
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11** TESTO ~~sh~~ Flange handle rod and cable operators
|Catalog no.<br>Description<br>Rating<br>30, 60 and 100 amp switches<br>~~———~~|Catalog no.<br>Description<br>Rating<br>30, 60 and 100 amp switches<br>~~———~~|Catalog no.<br>Description<br>Rating<br>30, 60 and 100 amp switches<br>~~———~~|
|---|---|---|
|CCP2-FLR1|Rod operator with painted handle|Type1, 3R, 12|
|CCP2-FLR1X|Rod operator with chrome handle|Type4X|
|CCP2-FLC1-36|36” Cable with painted handle|Type1, 3R, 12|
|CCP2-FLC1-36X|36” Cable with chrome handle|Type4X|
|CCP2-FLC1-60<br>CCP2-FLC1-60X<br>CCP2-FLC1-120|60” Cable with painted handle<br>60” Cable with chrome handle<br>120” Cable with painted handle|Type1, 3R, 12<br>Type4X<br>Type1, 3R, 12|
|CCP2-FLC1-120X|120” Cable with chrome handle|Type4X|
|200 and 400 amp switches|||
|CCP2-FLR2<br>CCP2-FLR2X<br>CCP2-FLC2-36<br>CCP2-FLC2-36X<br>CCP2-FLC2-60<br>CCP2-FLC2-60X<br>CCP2-FLC2-120|Rod operator with painted handle<br>Rod operator with chrome handle<br>36” Cable with painted handle<br>36” Cable with chrome handle<br>60” Cable with painted handle<br>60” Cable with chrome handle<br>120” Cable with painted handle|Type1, 3R, 12<br>Type4X<br>Type1, 3R, 12<br>Type4X<br>1, 3R, 12<br>Type4X<br>Type1, 3R, 12|
|CCP2-FLC2-120X|120” Cable with chrome handle|Type4X|
Flange rod operator kit for 30, 60 and 100 A switches.
Description
Flange rod and cable operators for use on 2- and 3-pole CCP2 switches (cannot be used with 2- or 3-pole 30, 60 or 100 amp switches already having a front or side rotary operating mechanism).
Flange rod operator kit for 200 and 400 A switches.
Handles are available in painted versions with NEMA 1, 3R and 12 ratings or chrome versions with a NEMA 4X rating.
Cable operators are available with 36, 60 and 120 inch cable lengths.
Agency information
- Type 1, 4X and 12
- RoHS compliant
Storage and operating temperature
- -20°C to 75°C (-4°F to 167°F)
Packaging
- Each handle is packaged individually as a kit
Flange cable operator kit for 30, 60 and 100 A switches.
Flange cable operator kit for 200 and 400 A switches.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-17
**11 — Disconnect switches**
Front rotary mechanisms for 200 and 400 A switches ee
## Phase barriers
Catalog numbers
- CCP2-PB2 (3-pole 200 A switches)
- CCP2-PB6 (3-pole 400 A switches)
Description
Phase barrier kit with two phase barriers for isolation between the lugs on 3-pole 200 and 400 A switches.
## Catalog numbers
- CCP2-RM2 (3-pole 200 A switches)
Packaged individually.
- CCP2-RM4 (3-pole 400 A switches)
Description
## Handle extension
Front rotary mechanisms for through-the-door operation and install on the front of 3-pole switches only. These units provide at-switch lockout/tagout capability for enhanced safety. Complete installation requires installing pistol handle (short or long) and 12 mm shaft.
Packaged individually.
Side rotary mechanism for 200 and 400 A switches
## Catalog number
- CCP2-HEX (1-, 2- and 3-pole 200 and 400 A switches)
## Description
A handle extension to provide additional leverage for operating the switch in installations that do not have rotary mechanisms or flange operators installed. Does not mount on switch, provision for tether provided.
Packaged individually.
## Catalog number
> • CCP2-SM (1-, 2- or 3-pole 200 and 400 A switches)
Description
Side rotary mechanism for through-the-side operation and installs on the left or right side (right side installation recommended) of any 1-, 2- or 3-pole 200 and 400 A switch. The side rotary mechanism does not provide for door interlock nor local lockout/tagout capability. Complete installation requires installing pistol handle (short or long) and 12 mm shaft.
Packaged individually.
## Terminal shrouds
Catalog numbers
- CCP2-TS2-3 (3-pole 200 A switches)
- CCP2-TS6-3 (3-pole 400 A switches)
Description
3-pole shroud kit with shields for isolating the lugs on 3-pole 200 and 400 A switches.
Packaged individually.
Eaton.com/bussmannseries
11-18
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## Auxiliary contacts for 30, 60 and 100 A switches
Catalog numbers
- CCP2-AUX (30 and 60 A switches)
## Installed on a CCP2-3-xx
Note: CCP2-AUX and CCP2-AUX-100 CANNOT be mounted on the right front and right side rotary operated versions, nor installed with the flange handle rod or cable operator.
- CCP2-AUX-100 (100 A switches)
## Description
NO+NC contact output to indicate the switching mechanism status on the CCP2. A single unit can be mounted on any 1-, 2- or 3-pole CUBEFuse CCP2 switch and the left front/left side rotary operated switches.
## Ratings
- 240 Vac max
- 5 A max
> • NC/NO contacts are closed/open when the CCP2 switch is in the “ON” position (closed)
## Catalog no. Switch Description Max per CCP2* Ratings ~~ee~~ 30/60 A
CCP2-AUX only Auxiliary contacts 1 per CCP2 N/NC for switch 5 A / 240 Vac 100 A (1-, 2- or 3-pole) CCP2-AUX-100 status only
- The CCP2-AUX CANNOT be mounted on the right front and right side rotary operated versions, nor installed with the flange handle rod or cable operator.
- ~~Be~~ De-energize all circuits and follow all prescribed safety procedures before installing or removing the auxiliary contact device.
## Agency information
- UL 98 Recognized, Guide WHTY2, File E155130
- cURus to Canadian Standard 22.2 No. 4-04
- Finger-safe in installed state
- RoHS compliant
- CE
## Wiring
- 16-20 AWG (1.5 to 0.5 mm[2] ) single and dual stranded wire
- 20 AWG (1.5 mm[2] ) single and dual solid wire
## Dimensions — in
**==> picture [259 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.8<br>o<br> 2.6 STRIP<br>33 NO 34 NO 1.9<br>re) | O<br>41 NC 42 NC<br>|_<br>© 3.7 L .190 °7<br> 0.3<br>**----- End of picture text -----**<br>
CCP2-AUX
- Torque 0.56 N•m (5 lb-in)
- Use only 75°C Cu wire
## Packaging
- CCP2-AUX and CCP2-AUX-100 are packaged individually
## Installation technique
- Mounts on the CCP2’s right side ONLY and mechanically interlocks with the CCP2 switch handle with provided hardware. The CCP2-AUX and CCP2-AUX-100 CANNOT be mounted on the right front and right side rotary operated versions, nor installed with the flange handle rod or cable operator.
## Storage and operating temperature
- -20°C to 75°C (-4°F to 167°F)
**==> picture [264 x 160] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.8<br>_I, fo)<br>© fo)<br> 2.9<br>33 NO STRIP 34 NO<br> 2.2<br>41 NC __- U0 42 NC<br>© oO ” 4 ©<br> .190<br> 3.7 0.3<br>**----- End of picture text -----**<br>
CCP2-AUX-100
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-19
## **11 — Disconnect switches**
## Auxiliary contacts for 200 and 400 A switches
## Catalog number
- CCP2-AUX-S (200 and 400 A switches)
## Installed on a CCP2-3-xx
Note: CCP2-AUX-S CANNOT be mounted on the same side as the side rotary mechanism CCP2-SM or the right side if a flange handle rod or cable operator is installed.
## Description
NO+NC contact output to indicate the switching mechanism status on the CCP2. A single unit can be mounted on either side of any 1-, 2- or 3-pole switch (cannot be mounted on the same side as the CCP2-SM side rotary mechanism or the right side if a flange handle rod or cable operator is installed).
## Ratings
- 240 Vac max
- 5 A max
> • NC/NO contacts are closed/open when the CCP2 switch is in the “ON” position (closed)
Catalog no. Switch Description Max per CCP2* Ratings ~~ee~~ Auxiliary contacts 200 and 1 per CCP2 CCP2-AUX-S NO+NC for switch 5 A / 240 Vac 400 A (1-, 2- or 3-pole) status
- The CCP2-AUX-S CANNOT be mounted on the same side where the side rotary mechanism (CCP2-SM) is installed.
- De-energize all circuits and follow all prescribed safety procedures before installing or removing the auxiliary contact device.
## Agency information
- UL 98 Recognized, Guide WHTY2, File E155130
- cURus to Canadian Standard 22.2 No. 4-04
- Finger-safe in installed state
- RoHS compliant
## Wiring
- 16-20 AWG (1.5 to 0.5 mm[2] ) single and dual stranded wire
- 20 AWG (1.5 mm[2] ) single and dual solid wire
- Torque 0.56 N•m (5 lb-in)
- Use only 75°C Cu wire
## Installation technique
- Mounts on either side of the 200 and 400 A switches and mechanically interlocks with the switch’s handle with provided hardware. The CCP2-AUX-S CANNOT be mounted on the same side with an installed CCP2-SM side rotary mechanism, or the flange cable/rod operating mechanisms.
## Storage and operating temperature
- -20°C to 75°C (-4°F to 167°F)
## Packaging
- Packaged individually.
Eaton.com/bussmannseries
11-20
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
PLC fuse monitor for 30, 60 and 100 A switches
## Catalog numbers
- CCP2-PLC-IND (30/60 A switches)
- CCP2-PLC-100 (100 A switches)
Description
A resettable three-phase fuse monitor that integrates with the I/O card in a Programmable Logic Controller (PLC). A single unit can be mounted on any 1-, 2- or 3-pole CUBEFuse CCP2 switch up to 100 A and the left front/ left side rotary operated switches.
A single unit monitors up to three phases. When used on 1- and 2-pole switches unused conductor(s) are removed after installation. The CCP2-PLC-IND and CCP2-PLC-100 CANNOT be mounted on the left front/left side rotary operated versions or if a multi-wire lug kit is installed or if a multi-wire lug kit is installed, or if the flange handle rod operator is installed.
## Ratings
- Signal output to PLC*
- +24 Vdc, 10 mA max
- Output signals
- Digital 0 Vdc (low), 24 Vdc max (high)
- 0 Vdc Low – fuse is good
## Agency information
- UL 98 Recognized, Guide WHTY2, File E155130
- cURus to Canadian Standard 22.2 No. 4-04
## Local indication
- Two distinct LEDs indicate unit power (green) and open fuse (red). Open fuse LED is resettable upon fuse replacement and the actuating the reset switch
## Wiring
> • For power, signal and ground connections use shielded twisted pair 22-24 AWG (0.34-0.25 mm[2] ) 300 V rated wire
## Installation technique
- Mounts on the left side ONLY of the CCP2 and mechanically interlocks with the CCP2 switch handle with hardware provided. The CCP2-PLC-IND and CCP2-PLC-100 CANNOT be mounted on the left front/left side rotary operated versions or if a multi-wire lug kit is installed or if the flange handle rod operator is installed.
## IP20 rating — yes
## Storage and operating temperature
- -20°C to 75°C (-4°F to 167°F)
## PLC programming
> • The CCP2-PLC-IND or CCP2-PLC-100 signal line is designed to provide a digital input to a PLC I/O card. In this case, a Programmable Logic Control program must be written to properly interpret the input signal to the PLC. The PLC program should check for consecutive high signals before taking action on a critical process.
- 24 Vdc High – fuse has opened
- When the fuse opens, the output signal is sent high and will remain high until the unit is reset.
## Emissions and immunity testing
- IEC 60947-1: Voltage Switchgear and Control Gear
- IEC 61000-6-2: Electromagnetic Compatibility (EMC)
- IEC 61000-4-2: Electrostatic Discharge Immunity - Test at level 3 (6 kV-Contact Discharge) and level 2 (4 kV-Air Discharge)
- IEC 61000-4-3: Electromagnetic Compatibility - Radiated, Radiofrequency, Electromagnetic Field Immunity test at level x (20 V/m)
- IEC 61000-4-4: Electromagnetic Compatibility - Testing and Measurement Techniques at level 3 (± 2kV - Power Port and ±1 kV - I/O Ports)
- IEC 61000-4-5: Electromagnetic Compatibility - Surge Immunity test at level 4 (±4 kV)
- IEC 61000-4-6: Immunity to Conducted Disturbances at level 3 (10 V)
|Catalogno.|Switch|Description|Max per<br>CCP2**|Signal<br>output<br>to PLC|Min.<br>circuit<br>volts|
|---|---|---|---|---|---|
|CCP2-PLC-IND<br>CCP2-PLC-100|30/60 A<br>only<br>100 A<br>only|Wired<br>remote fuse<br>indication<br>for PLC<br>applications|1 per CCP2<br>(1, 2- or<br>3-pole)|24 Vdc/<br>10 mA|100 Vac|
- ** The CCP2-PLC-IND and CCP2-PLC-100 CANNOT be mounted on the left front/ left side rotary operated versions or if a multi-wire lug kit is installed.
- De-energize all circuits and follow all prescribed safety procedures before installing or removing the CCP2-PLC-IND or CCP2-PLC-100.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-21
**11 — Disconnect switches**
Installed on a CCP2-3-xx
## PLC wiring schematic
PLC power supply PLC fuse monitor +24 Vdc ~~a~~ +24 Vdc 0 Vdc/Gnd 0 Vdc/Gnd ~~i.~~ Signal 10 mA max.
CCP2-PLC-IND mounted on a 3-pole switch and using the fork terminals. When mounted on a 2- or 1-pole switch, remove unused leads.
The PLC fuse monitor needs to be powered by the same +24 Vdc and ground (0 Vdc/Gnd return) terminals that feed the ° PLC input card. If it is not, it may improperly signal. +24 Vdc If feeding multiple 0 Vdc/Gnd 5O 6eo} PLC fuse monitors from different power supplies, PLC there must be multiple input cards being powered input card by those same power supplies as well.
Note: the CCP2-PLC-IND CANNOT be mounted on the left front/left side rotary operated versions or if the multi-wire lug kit is installed or if the flange handle rod operator is installed.
## Dimensions — in
**==> picture [462 x 352] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.8<br>OI iE — Pin interlocks with<br>CCP2 switch handle<br>-<br>TT aD <= Ds om<br>i LY) ©<br> 2.6 1.9<br>[ Je rel; 6<br> 3.7 0.3<br>30 and 60 A CCP<br> 2.0<br>Pin interlocks with<br>CCP2 switch handle<br>cnn _ -<br>a jp Cc —p. = Ds<br> 2.9 [oo 2.2 les<br>cc a ——«<br> 0.3<br> 3.7 a<br>ON RESET STATUS +24vDC +24vDC GND SIG<br>1L1 2T1<br>2<br>3L2<br>4T<br>5L3 6T3<br>ON RESET STATUS +24vDC +24vDC GND SIG<br>1L1 2T1<br>3L2 2<br>4T<br>5L3 3<br>6T<br>**----- End of picture text -----**<br>
100 A CCP
Eaton.com/bussmannseries
11-22
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11** ABST ~~an~~
## Ordering a complete switch installation
## 30 and 60 A CCP2 switches
For a complete assembly, select from the following required and optional components, and accessories.
|Required|~~Pp~~|Catalog no.|Catalog no.|Catalog no.|
|---|---|---|---|---|
|||Switches|Amps|Poles|
|||Switch (used alone or with flange cable or flange rod handles)<br>~~Pp~~<br>~~Po~~|||
||~~Pp~~<br>~~x=~~|CCP2-1-30CF<br>~~Pp~~<br>~~x=~~|30<br>~~x=~~|1<br>~~Po~~<br>~~x=~~|
|||CCP2-2-30CF<br>~~Pp~~<br>~~—~~<br>~~x=~~||2<br>~~Po~~<br>~~x=~~|
|||CCP2-3-30CF<br>~~—~~<br>~~x=~~||3<br>~~x=~~|
|||CCP2-1-60CF<br>~~x=~~|60<br>~~|p~~<br>~~x=~~|1<br>~~|p~~<br>~~x=~~|
|||CCP2-2-60CF<br>~~x=~~||2<br>~~|p~~<br>~~x=~~|
|||CCP2-3-60CF<br>~~x=~~||3<br>~~|p~~<br>~~x=~~|
|And|||||
|Optional|~~=~~|Flange handle rod<br>operator<br>~~=~~|Description — 3-pole switches only<br>~~=~~|Rating<br>~~=~~|
|||CCP2-FLR1-21<br>~~=~~|Red/black painted handle<br>~~a~~<br>~~=~~|1, 3R and 12<br>~~ee~~<br>~~=~~|
|||CCP2-FLR1-21X<br>~~=~~|Chrome handle<br>~~=~~|4X<br>~~=~~|
|||Or|||
|||Flange handle cable<br>operator<br>~~PR~~|Description - 3-pole switches only, cannot be used with side or<br>front rotary mechanisms<br>~~PR~~|Rating<br>~~Po~~|
|||CCP2-FLC1-36<br>~~PR~~|36” cable, red/black painted handle<br>~~PR~~|Type 1, 3R, 12<br>~~Po~~|
|||CCP2-FLC1-36X<br>~~PR~~|36” cable, chrome handle<br>~~PR~~|Type 4X<br>~~Po~~|
|||CCP2-FLC1-60|60” cable, red/black painted handle|Type 1, 3R, 12|
|||CCP2-FLC1-60X|60” cable, chrome handle|Type 4X|
|||CCP2-FLC1-120|120” cable, red/black painted handle|Type 1, 3R, 12|
|||CCP2-FLC1-120X|120” cable, chrome handle<br>~~]—~~|Type 4X<br>~~]—~~|
||||||
|||Multi-wire lug kits|Description||
|||CCP2-MW1-3|3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3||
|And|||||
|Accessories||Terminal shrouds|Description||
|||CCP2-TS1-3|Pack of 3||
|||Auxiliary contacts|Description — mounts on right side, cannot be used with flange handle rod or<br>cable operator||
|||CCP2-AUX|NO/NC, 5 A / 240 V||
|||PLC fuse monitor|Description — mounts on left side, cannot be used with flange handle rod<br>operator||
|||CCP2-PLC-IND|Signal output 24 Vdc / 10 mA||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-23
**11 — Disconnect switches**
Ordering a complete switch installation
30 and 60 A CCP2 clockwise rotary switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no. Switches Amps Poles Right front rotary CCP2R-2-30CF 2 30 CCP2R-3-30CF 3 ~~— po~~ CCP2R-2-60CF 2 ~~OO~~ 60 ~~po~~ CCP2R-3-60CF 3 ~~oF~~ ~~**po**~~ Left front rotary CCP2RL-2-30CF 2 30 CCP2RL-3-30CF 3 ~~SS ————E~~ CCP2RL-2-60CF 2 ~~TT~~ 60 ~~pO~~ CCP2RL-3-60CF 3 ~~SS po————~~ Right side rotary CCP2S-2-30CF 2 30 CCP2S-3-30CF 3 ~~po po~~ CCP2S-2-60CF 2 ~~——a~~ 60 ~~eee~~ CCP2S-3-60CF 3 ~~J~~ ~~**p** Oo~~ And Rotary handles Description Rating CCP2-H4X-B1 Selector handle — black/grey ~~a~~ CCP2-H4X-R1 Selector handle — red/yellow Type 1, 4X, 12 CCP2-H4X-B2 Pistol handle — black/grey ~~———~~ CCP2-H4X-R2 Pistol handle — red/yellow And Shafts (8 mm) Length CCP2-SH1-290 290 mm ~~Em~~ TN ~~**a**~~ CCP2-SH1-490 490 mm NFPA 79 compliant Color handle CCP2-NFPA-1 Red And ~~|~~ Multi-wire lug kits Description CCP2-MW1-3 3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
Eaton.com/bussmannseries
11-24
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
|And|And|And|And|
|---|---|---|---|
|Accessories|~~Qe~~<br>~~qt~~|Terminal shrouds<br>~~Qe~~|Description<br>~~Qe~~|
|||CCP2-TS1-3<br>~~Qe~~<br>~~qt~~|Pack of 3<br>~~Qe~~|
||~~qt~~|Auxiliarycontacts<br>~~qt~~|Description — use with CCP2RL-(poles)-30/60CF switches|
|||CCP2-AUX<br>~~qt~~|NO/NC, 5 A / 240 V|
||~~qt~~|PLC fuse monitor<br>~~qt~~|Description — use with CCP2R-(poles)-30/60CF and CCP2S-(poles)-30/60CF<br>switches|
|||CCP2-PLC-IND|Signal output 24 Vdc / 10 mA|
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-25
**11 — Disconnect switches** ~~<0~~
## Ordering a complete switch installation
30 and 60 A CCP2 counterclockwise switches
For a complete assembly, select from the following required and optional components, and accessories.
|Required<br>~~C~~||Catalog no.|Catalog no.|Catalog no.|
|---|---|---|---|---|
|||Switches|Amps|Poles|
|||Left side rotary|||
||~~f~~<br>~~————~~|CCP2SL-2-30CF<br>~~—~~<br>~~f~~<br>~~————~~|30<br>~~fF~~<br>~~————~~|2<br>~~fF~~<br>~~————~~|
|||CCP2SL-3-30CF<br>~~f~~<br>~~————~~||3<br>~~fF~~<br>~~————~~|
|||CCP2SL-2-60CF<br>~~f~~<br>~~————~~|60<br>~~fF~~<br>~~————~~|2<br>~~fF~~<br>~~————~~|
|||CCP2SL-3-60CF<br>~~————~~||3<br>~~————~~|
||~~oo~~<br>Cie<br>~~_—____——~~|And<br>~~oo~~|||
|||Rotaryhandles<br>~~oo~~|Description<br>~~oo~~|Rating|
|||CCP2-H4X-B1L<br>~~oo~~<br>~~**a**~~|Selector handle — black/grey<br>~~oo~~<br>~~**a**e~~|Type 1, 4X, 12<br>~~e~~<br>~~—____——~~|
|||CCP2-H4X-R1L<br>~~**a**~~|Selector handle — red/yellow<br>~~**a**e~~||
|||CCP2-H4X-B2L<br>~~**a**~~<br>~~a ee~~|Pistol handle — black/grey<br>~~**a**e~~<br>~~ee~~||
|||CCP2-H4X-R2L<br>~~**a**~~<br>~~—____——~~|Pistol handle — red/yellow<br>~~**a**e~~<br>~~ee~~<br>~~—____——~~||
||~~_—____——~~<br>~~C~~|And<br>~~—____——~~|||
|||Shafts (8 mm)<br>~~—____——~~|Length<br>~~—____——~~||
|||CCP2-SH1-290<br>~~—____——~~|290 mm<br>~~—____——~~||
|||CCP2-SH1-490<br>~~—____——~~<br>|490 mm<br>~~—____——~~<br>||
||~~_—____——~~<br>~~Cee~~|NFPA 79 compliant<br>handle<br>~~—____——~~<br>~~ee~~|Color<br>~~—____——~~<br>~~ee~~||
|||CCP2-NFPA-1<br>~~ee~~|Red<br>~~ee~~||
|And<br>~~C~~|||||
|Optional||Multi-wire lug kits|Description||
|||CCP2-MW1-3|3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3||
|And<br>~~eee~~|||||
|Accessories||Terminal shrouds|Description||
|||CCP2-TS1-3|Pack of 3||
|||Auxiliarycontacts|Description —mounts on right side||
|||CCP2-AUX|NO/NC, 5 A / 240 V||
Eaton.com/bussmannseries
11-26
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## BTM
## Ordering a complete switch installation
## 100 A CCP2 switches
For a complete assembly, select from the following required and optional components, and accessories.
|Required|~~—~~|Catalog no.|Catalog no.|Catalog no.|
|---|---|---|---|---|
|||Switches|Amps|Poles|
|||Switch (used alone or with flange cable or flange rod handles)<br>~~—~~<br>~~—~~|||
||~~—~~<br>~~Sa~~<br>~~—~~|CCP2-1-100CF<br>~~—~~<br>~~Sa~~|100<br>~~Sa~~|1<br>~~—~~<br>~~Sa~~|
|||CCP2-2-100CF<br>~~—~~<br>~~Sa~~<br>~~—~~||2<br>~~—~~<br>~~Sa~~<br>~~oe~~|
|||CCP2-3-100CF<br>~~Sa~~<br>~~—~~||3<br>~~Sa~~<br>~~oe~~|
|And<br>~~—~~<br>~~oe~~|||||
|Optional|~~EE~~|Flange handle rod<br>operator<br>~~EE~~|Description — 3-pole switches only<br>~~EE~~|Rating<br>~~EE~~|
|||CCP2-FLR1-21<br>~~EE~~|Red/black painted handle<br>~~EE~~|1, 3R and 12<br>~~EE~~|
|||CCP2-FLR1-21X<br>~~EE~~|Chrome handle<br>~~EE~~|4X<br>~~EE~~|
||~~Se~~|Or<br>~~Se~~|||
|||Flange handle cable<br>operator<br>~~Se~~|Description - 3-pole switches only, cannot be used with side or<br>front rotary mechanisms<br>~~Se~~|Rating<br>~~Se~~|
|||CCP2-FLC1-36<br>~~Se~~|36” cable, red/black painted handle<br>~~pO~~<br>~~Se~~|Type 1, 3R, 12<br>~~Se~~|
|||CCP2-FLC1-36X<br>~~Se~~|36” cable, chrome handle<br>~~Se~~|Type 4X<br>~~Se~~|
|||CCP2-FLC1-60<br>~~Se~~|60” cable, red/black painted handle<br>~~Se~~|Type 1, 3R, 12<br>~~Se~~|
|||CCP2-FLC1-60X<br>~~Se~~|60” cable, chrome handle<br>~~Se~~|Type 4X<br>~~Se~~|
|||CCP2-FLC1-120<br>~~Se~~<br>~~J~~|120” cable, red/black painted handle<br>~~Se~~<br>~~J~~|Type 1, 3R, 12<br>~~Se~~<br>~~J~~|
|||CCP2-FLC1-120X<br>~~Se~~<br>~~J~~|120” cable, chrome handle<br>~~Se~~<br>~~J~~|Type 4X<br>~~Se~~<br>~~J~~|
||||||
|||Multi-wire lug kits|Description||
|||CCP2-MW1-6|6-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3||
|And|||||
|Accessories||Terminal shrouds|Description||
|||CCP2-TS1-6|Pack of 3||
|||Auxiliary contacts|Description — mounts on right side, cannot be used with flange handle rod or<br>cable operator||
|||CCP2-AUX-100|NO/NC, 5 A / 240 V||
|||PLC fuse monitor|Description — mounts on left side, cannot be used with flange handle rod<br>operator||
|||CCP2-PLC-100|Signal output 24 Vdc / 10 mA||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-27
**11 — Disconnect switches** ran Ordering a complete switch installation
100 A CCP2 clockwise rotary switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no. Switches Amps Poles Right front rotary CCP2R-2-100CF 2 100 CCP2R-3-100CF 3 ~~—~~ Left front rotary CCP2RL-2-100CF 2 100 CCP2RL-3-100CF 3 ~~— oO~~ Right side rotary ~~—~~ CCP2S-2-100CF 2 100 CCP2S-3-100CF 3 ~~.———i=~~ And ~~EE~~ Rotary handles Description Rating CCP2-H4X-B1 Selector handle — black/grey CCP2-H4X-R1 Selector handle — red/yellow ~~a~~ Type 1, 4X, 12 CCP2-H4X-B2 Pistol handle — black/grey CCP2-H4X-R2 Pistol handle — red/yellow ~~CC~~ And ~~oe ——_—E~~ Shafts (8 mm) Length CCP2-SH1-290 290 mm CCP2-SH1-490 490 mm ~~EE~~ NFPA 79 compliant Color handle CCP2-NFPA-1 Red And Multi-wire lug kits Description CCP2-MW1-6 6-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
Eaton.com/bussmannseries
11-28
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
And Terminal shrouds Description CCP2-TS1-6 Pack of 3 ~~Qe~~ Auxiliary contacts Description — cannot be used on right front or right side operated switches CCP2-AUX-100 NO/NC, 5 A / 240 V ~~qe~~ PLC fuse monitor Description — Cannot be used on left front or left side operated switches CCP2-PLC-100 Signal output 24 Vdc / 10 mA
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-29
**11 — Disconnect switches** ~~<0~~
Ordering a complete switch installation
## 100 A CCP2 counterclockwise switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no. Switches Amps Poles Left side rotary CCP2SL-2-100CF 2 100 CCP2SL-3-100CF 3 ~~ee~~ And Rotary handles Description Rating CCP2-H4X-B1L Selector handle — black/grey ~~a~~ CCP2-H4X-R1L Selector handle — red/yellow Type 1, 4X, 12 CCP2-H4X-B2L Pistol handle — black/grey ~~a~~ CCP2-H4X-R2L Pistol handle — red/yellow Ca ~~oe~~ And ~~a~~ Shafts (8 mm) Length CCP2-SH1-290 290 mm CCP2-SH1-490 490 mm ~~<————~~ NFPA 79 compliant Color handle CCP2-NFPA-1 Red ~~wr~~ And Multi-wire lug kits Description CCP2-MW1-6 6-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3 And ~~eee~~ Terminal shrouds Description CCP2-TS1-6 Pack of 3 Auxiliary contacts Description — mounts on right side CCP2-AUX-100 NO/NC, 5 A / 240 V ~~—~~ 11-30 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018 Eaton.com/bussmannseries
**Disconnect switches — 11**
## About the UL Class CF CUBEFuse
## Features
- Smallest installed footprint of any UL Class CC, J, or R fuse solution
- Easy application using CUBEFuse holders (TCFH_N), UL 98 Compact Circuit Protector (CCP2) switches and Compact Circuit Protector Base (CCP2B up to 100 A). See data sheet 9007 for details on the CUBEFuse holder, 10801 for details on the CCP2-_CF switch and 1161 for the CCP2B.
- Holders and switches have an amp rating rejection feature to help prevent overfusing; 30, 60 and 100 A switches and holders will hold any CUBEFuse up to its rating, 200 and 400 A switches and 200, 225 and 400 A holders will hold any CUBEFuse 110 A and above up to its rating
- UL Class CF with Class J time-delay electrical performance
The Bussmann series Low-Peak CUBEFuse is a UL Class CF currentlimiting, dual-element, time-delay branch circuit fuse with Class J electrical performance. Available in indicating and non-indicating versions, this finger-safe fuse has a very compact, space-saving size and is easily applied using the CUBEFuse holder (TCFH_N), UL 98 Compact Circuit Protector switch (CCP2-_CF) or Compact Circuit Protector Base (CCP2B up to 100 A) used in the Quik-Spec Coordination Panelboard).
## Ratings
- Volts
- 600 Vac
- 300 Vdc
- Amps
- 6-400 A (indicating)
- 1-400 A (non-indicating)
- Interrupting rating
- 300 kA RMS Sym. (Up to 100 A UL)
- 200 kA RMS Sym. (110 to 400 A UL)
- 200 kA RMS Sym. (Up to 100 A CSA)
- 100 kA DC (Up to 400 A UL and up to 100 A CSA)
## Agency information
- UL Listed Class CF fuse: Guide JDDZ, File E4273 (up to 400 A)
- CSA[®] Certified fuse: Class 1422-02, File 053787_C_000 (up to 100 A)
- CE
- RoHS compliant
## Catalog numbers (amps)
## Indicating CUBEFuse
|TCF6<br>TCF10|TCF30<br>TCF35|TCF70<br>TCF80|TCF150<br>TCF175|TCF350<br>TCF400|
|---|---|---|---|---|
|TCF15<br>TCF17-1/2<br>TCF20|TCF40<br>TCF45<br>TCF50|TCF90<br>TCF100<br>TCF110|TCF200<br>TCF225<br>TCF250||
|TCF25|TCF60|TCF125|TCF300||
|Non-Indicating CUBEFuse|Non-Indicating CUBEFuse||||
|TCF1RN|TCF20RN|TCF50RN|TCF110RN|TCF250RN|
|TCF3RN|TCF25RN|TCF60RN|TCF125RN|TCF300RN|
|TCF6RN|TCF30RN|TCF70RN|TCF150RN|TCF350RN|
|TCF10RN<br>TCF15RN|TCF35RN<br>TCF40RN|TCF80RN<br>TCF90RN|TCF175RN<br>TCF200RN|TCF400RN|
|TCF17-1/2RN|TCF45RN|TCF100RN|TCF225RN||
- Available in indicating and non-indicating versions
- The indicating version features local easyID™ open fuse technology for faster troubleshooting and reduced downtime
- Faster response to damaging faults helps reduce destructive thermal and magnetic forces
- True dual-element fuse construction with a minimum 10 seconds time-delay at 500% of rating
- Long time-delay minimizes nuisance openings caused by temporary overloads and transient surges
- Up to 300 kA interrupting rating safely interrupts virtually any fault
- Robust cycling and inrush current withstand
- Low let-through currents under fault conditions
- Provides Type 2 “No Damage” protection for IEC motor starters when properly sized
- Easy selective coordination with any other Bussmann series Low-Peak Class CC, J, L or RK1 fuse with simple 2:1 amp ratio between upstream and downstream fuses
- Finger-safe status depends on final, installed application, and will require using accessory shrouds for 110 to 400 A ratings.
## CUBEFuse (cat. no. TCFH_N) holders
The CUBEFuse is also used in holders that can be dovetail together for the smallest footprint possible of any Class J fuse solution (see data sheet no. 9007 for details).
Finger-safe DIN-Rail or panel mount holders up to 100 A.
- 30 A holder accepts any CUBEFuse up to 30 A.
- 60 amp holder accepts any CUBEFuse up to 60 A.
- 100 amp holder accepts any CUBEFuse up to 100 A.
Panel mount holders from 200 to 400 A.
- 200 A holder accepts any CUBEFuse from 110 to 200 A
- 225 A* holder accepts any CUBEFuse from 110 to 225 A
- 400 A holder accepts any CUBEFuse from 110 to 400 A Finger-safe installation achievable for three ganged holders and lug kits with shroud
- 200 A and 225 A holders share the same overall dimensions, but the 200 A holder will reject a 225 A fuse.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-31
**11 — Disconnect switches** ~~Ta~~ 2s Ordering a complete switch installation 200 A CCP2 switches
For a complete installation, select from the following required and optional components, and accessories.
Catalog no. Switches Amps Poles CCP2-1-200CF 1 CCP2-2-200CF 200 2 CCP2-3-200CF 3 ~~eo~~ And Lug kits Description CCP2-L2-1 Stainless steel lug, 75° Cu only, 350 kcmil-4, 1 per pack fi rs ~~ee~~ CCP2-L2-1A Aluminum lug, 75°C Cu/Al, 350 kcmil-4, 1 per pack CCP2-MW2-3 3-port multi-wire lug, 75°C Cu/Al, 2-14, 3 per pack, includes terminal shroud CCP2-MW2-6 6-port multi-wire lug, 75°C Cu/Al, 6-14, 3 per pack, includes terminal shroud ~~ee~~ And Rotary mechanisms Description CCP2-SM Side rotary mechanism - mounts on left or right side of 1-, 2- and 3-pole switches ~~|~~ CCP2-RM2 Front rotary mechanism - mounts only on 3-pole switches, requires clockwise rotating handle ~~aL...~~ And Rotation - must match Rotary handles Description switch rotation Rating CCP2-H4X-B3 Short pistol handle — black/grey Clockwise CCP2-H4X-R3 Short pistol handle — red/yellow For use with front rotary mechanism or side rotary CCP2-H4X-B4 Long pistol handle — black/grey mechanism CCP2-SM on CCP2-H4X-R4 Long pistol handle — red/yellow the switch’s right side Type 1, 4X, 12 CCP2-H4X-B3L Short pistol handle — black/grey Counterclockwise CCP2-H4X-R3L Short pistol handle — red/yellow Use only if installing side rotary mechanism CCP2CCP2-H4X-B4L Long pistol handle — black/grey SM on the switch’s left ~~=o~~ — ~~$S——~~ CCP2-H4X-R4L Long pistol handle — red/yellow side And Shafts (12 mm) Length CCP2-SH2-225 225 mm CCP2-SH2-425 425 mm ~~_~~ NFPA 79 Color compliant handle CCP2-NFPA-2 Red ~~a~~
Eaton.com/bussmannseries
11-32
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
|Optional||Or<br>~~eee~~|Or<br>~~eee~~|Or<br>~~eee~~|
|---|---|---|---|---|
|||Flange handle rod<br>operator|Description — 3-pole switches<br>only, cannot be used with side or<br>front rotarymechanisms|Rating|
|||CCP2-FLR2-21|Red/black, painted handle|Type 1, 3R and 12|
|||CCP2-FLR2-21X|Chrome handle|Type 4X|
||~~a~~|Or<br>~~Pee~~<br>~~a~~|||
|||Flange handle<br>cable operator<br>~~a~~|Description - 3-pole switches only,<br>cannot be used with side or front<br>rotarymechanisms|Rating|
|||CCP2-FLC2-36<br>~~a~~|36“ cable, red/black painted handle|Type 1, 3R and 12|
|||CCP2-FLC2-36X<br>~~a~~|36“ cable, chrome handle|Type 4X|
|||CCP2-FLC2-60<br>~~a~~|60“ cable, red/black painted handle|Type 1, 3R and 12|
|||CCP2-FLC2-60X<br>~~a~~|60“ cable, chrome handle|Type 4X|
|||CCP2-FLC2-120<br>~~a~~<br>~~ee~~|120“ cable, red/black painted handle<br>~~es~~|Type 1, 3R and 12<br>~~es~~|
|||CCP2-FLC2-120X<br>~~a~~<br>~~ee~~|120“ cable, chrome handle<br>~~es~~|Type 4X<br>~~es~~|
|And<br>~~eees~~<br>~~{—_—_———~~|||||
|Accessories|fA<br>~~{—_—_———~~|Terminal shrouds<br>~~ee~~<br>~~{—_—_———~~|Description<br>~~{—_—_———~~||
|||CCP2-TS2-3<br>~~ee~~<br>~~{—_—_———~~|3-pole terminal shroud with phase shields, 1 per pack<br>~~{—_—_———~~||
|||Phase barriers<br>~~ee~~<br>~~{—_—_———~~|Description<br>~~{—_—_———~~||
|||CCP2-PB2<br>~~ee~~<br>~~{—_—_———~~|Phase barriers, 2 per pack<br>~~{—_—_———~~||
||And<br>~~{—_—_———~~||||
||~~et~~|Control wire<br>terminals<br>~~et~~|Description<br>~~et~~||
|||CCP2-CWK2<br>~~et~~|1/4” quick-connect control wire terminals - mounts on installed lug (cannot be used<br>with lug CCP2-L2-1), 12 per pack<br>~~et~~||
|||Auxiliarycontacts|Description||
|||CCP2-AUX-S|NO/NC, 5 A, 240 V - Can be mounted on right or left side||
|||Handle extension|Description||
|||CCP2-HEX|Handle extension to facilitate operating 1-, 2 and 3-pole switches. Cannot be used<br>when side or front rotary mechanisms or flange handle rod or cable operators are<br>installed.||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-33
**11 — Disconnect switches** ata Ordering a complete switch installation
## 400 A CCP2 switches
For a complete installation, select from the following required and optional components, and accessories.
|~~e—-—~~|~~e—-—~~|Catalog no.|Catalog no.|Catalog no.|Catalog no.|
|---|---|---|---|---|---|
|||Switches<br>~~—-—~~|Amps<br>~~—-—~~|Poles||
|Required|~~e—-—~~|CCP2-1-400CF<br>~~—-—~~|400<br>~~—-—~~|1||
|||CCP2-2-400CF<br>~~—-—~~||2||
|||CCP2-3-400CF<br>~~—-—~~||3||
||~~e—-—~~<br>e6,.<<br>~~—=~~|And<br>~~—-—~~<br>~~—————~~<br>~~—=~~||||
|||Lug kits<br>~~—————~~<br>~~—=~~|Description<br>~~—————~~<br>~~—=~~|||
|||CCP2-L4-1<br>~~—————~~<br>~~—=~~|Stainless steel lug, 75° Cu only, 500 kcmil-3, 1 per pack<br>~~—————~~<br>~~—=~~|||
|||CCP2-L4-1A<br>~~—————~~<br>~~—=~~|Aluminum lug, 75° Cu only, 500 kcmil-3, 1 per pack<br>~~—————~~<br>~~—=~~|||
|||CCP2-L4B-3<br>~~—————~~<br>~~—=~~|Stainless steel lug, 75° Cu only, 750-500 kcmil, 3 per pack, includes terminal shroud<br>~~—————~~<br>~~—=~~|||
|||CCP2-L4B-3A<br>~~—————~~<br>~~—=~~|Aluminum lug, 75°C Cu/Al, 750-500 kcmil, 3 per pack, includes terminal shroud<br>~~—————~~<br>~~—=~~|||
|||CCP2-MW6-6<br>~~—=~~|6-port multi-wire lug, 75°C Cu/Al, 1/0-14, 3 per pack, includes terminal shroud<br>~~—=~~|||
|||CCP2-L6-3<br>~~—=~~|2-port stainless steel lug, 75° Cu only, 500 kcmil-2, 3 per pack, includes terminal shroud<br>~~—=~~|||
|||CCP2-L6-3A<br>~~—=~~|2-port aluminum lug kit, 75° Cu/Al only, 500 kcmil-2, 3 per pack, includes terminal shroud<br>~~—=~~|||
|And||||||
|Optional<br>~~|~~|~~|~~|Rotary<br>mechanisms|Description|||
|||CCP2-SM<br>|Side rotary mechanism - mounts on left or right side of 1-, 2- and 3-pole switches<br>|||
||~~|~~|CCP2-RM4<br>|Front rotary mechanism - mounts only on 3-pole switches, requires clockwise<br>rotating handle<br>|||
||~~|Em~~<br>~~_~~|And<br>~~Em~~||||
|||Rotaryhandles<br>~~Em~~|Description<br>~~Em~~|Rotation - must match<br>switch rotation<br>~~Em~~|Rating|
|||CCP2-H4X-B3<br>~~Em~~|Short pistol handle — black/grey<br>~~Em~~|Clockwise<br>For use with front rotary<br>mechanism or side rotary<br>mechanism CCP2-SM on<br>the switch’s right side<br>~~Em~~|Type 1, 4X, 12<br>~~oo~~<br>|
|||CCP2-H4X-R3<br>~~Em~~|Short pistol handle — red/yellow<br>~~Em~~|||
|||CCP2-H4X-B4<br>~~Em~~|Long pistol handle — black/grey<br>~~Em~~|||
|||CCP2-H4X-R4<br>~~Em~~|Long pistol handle — red/yellow<br>~~Em~~|||
|||CCP2-H4X-B3L<br>~~Em~~<br>~~oo~~<br>|Short pistol handle — black/grey<br>~~Em~~<br>~~oo~~<br>|Counterclockwise<br>Use only if installing side<br>rotary mechanism CCP2-<br>SM on the switch’s left<br>side<br>~~Em~~<br>~~oo~~<br>||
|||CCP2-H4X-R3L<br>~~Em~~<br>~~oo~~<br>|Short pistol handle — red/yellow<br>~~Em~~<br>~~oo~~<br>|||
|||CCP2-H4X-B4L<br>~~Em~~<br>~~oo~~<br>|Long pistol handle — black/grey<br>~~Em~~<br>~~oo~~<br>|||
|||CCP2-H4X-R4L<br>~~Em~~<br>~~oo~~<br>|Long pistol handle — red/yellow<br>~~Em~~<br>~~oo~~<br>|||
||~~_ _———————~~|And<br>~~oo~~<br>~~_———————~~||||
|||Shafts (12 mm)<br>~~oo~~<br>~~_———————~~|Length<br>~~oo~~<br>~~_———————~~|||
|||CCP2-SH2-225<br>~~oo~~<br>~~_———————~~|225 mm<br>~~oo~~<br>~~_———————~~|||
|||CCP2-SH2-425<br>~~oo~~<br>~~_———————~~|425 mm<br>~~oo~~<br>~~_———————~~|||
||~~NN~~|NFPA 79<br>compliant handle<br>~~NN~~|Color<br>~~NN~~|||
|||CCP2-NFPA-2<br>~~NN~~|Red<br>~~NN~~|||
Eaton.com/bussmannseries
**Disconnect switches — 11** Or Flange handle rod Description - 3-pole switches only, cannot be used with side operator or front rotary mechanisms Rating oihe. CCP2-FLR2-21 Red/black, painted handle Type 1, 3R, 12 ~~a~~ CCP2-FLR2-21X Chrome handle Type 4X Or ~~]~~ Flange handle Description - 3-pole switches only, cannot be used with side cable operator or front rotary mechanisms Rating CCP2-FLC2-36 36“ cable, red/black painted handle Type 1, 3R, 12 CCP2-FLC2-36x 36“ cable, chrome handle Type 4X CCP2-FLC2-60 60“ cable, red/black painted handle Type 1, 3R, 12 CCP2-FLC2-60x 60“ cable, chrome handle Type 4X CCP2-FLC2-120 120“ cable, red/black painted handle Type 1, 3R, 12 ~~SS~~ | ~~——==SeCe~~ CCP2-FLC2-120x 120“ cable, chrome handle Type 4X And ~~a~~ Terminal shrouds Description CCP2-TS6-3 3-pole terminal shroud with phase shields, 1 per pack Phase barriers Description CCP2-PB6 Phase barriers, 2 per pack And Auxiliary contacts Description CCP2-AUX-S NO/NC, 5 A, 240 V - Can be mounted on right or left side ~~-~~ Handle extension Description Handle extension to facilitate operating 1-, 2 and 3-pole switches. Cannot be used CCP2-HEX when side or front rotary mechanisms, or flange handle rod and cable mechanisms are installed. ~~—~~ BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018 Eaton.com/bussmannseries 11-35
**11 — Disconnect switches**
## CUBEFuse Compact Circuit Protector
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
## Lineside bolt-on bus connector and torque
- Bolt-mounted design into Quik-Spec Coordination Panelboard bus
- • #10-32 UNC hex flange Phillips screw; 2.8 N•m (25 lb-In)
Loadside box lug terminal conductor data
- See conductor table for details
## Loadside fork terminal
- Max. 30 A suitable for use with #8-32 UNC screw
- Lockout/tagout
- 1/4” lock
**==> picture [224 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
1-Pole 2-Pole 3-pole<br>CCP2B-1-_CF CCP2B-2-_CF CCP2B-3-_CF<br>**----- End of picture text -----**<br>
**==> picture [44 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Description<br>**----- End of picture text -----**<br>
The revolutionary Bussmann series Compact Circuit Protector UL 98 Disconnect Switch (CCP2) with CUBEFuse™ is a horsepower rated fused disconnect switch. Primarily used in the Bussmann series Quik-Spec™ Coordination Panelboard, the CCP2B with CUBEFuse simplifies selective coordination for code complaince along with a lockout/tagout feature for isolating individual branch circuit loads to promote safe work practices.
## Features
- Uses finger-safe, current-limiting Class CF CUBEFuse with Class J performance available, time-delay or fast-acting versions from 1 to 100 amps
- Patented amp rating rejection feature helps prevent overfusing
- High 200 kA short-circuit current rating
- Disconnect rated to provide a means for load isolation
- 1,2 and 3 pole versions full voltage rated at 600 Vac
- Up to 125 Vdc ratings
- UL 98 Listed for branch circuit disconnect
- 1-, 2- and 3-pole versions are horsepower rated
## Local open fuse indication
- Light illumination requires closed circuit and minimum 90 volts
- Carton quantity and shipping weight
|Item<br>Poles<br>lbs (kg)<br>upto 60 ampswitches<br>6<br>1.7 (0.77)<br>~~ee~~|
|---|
|70 to 100 ampswitches<br>6<br>2.6 (1.18)|
## Environmental data
- Storage and operating temperature -20°C to 75°C**
- ** For fuse performance under or above 25°C, consult fuse performance derating charts.
Available Bussmann series fuses
|UL fuse<br>class|Type/description|Volts|Data sheet<br>no.|
|---|---|---|---|
||Indicating time-delay, Low-Peak|||
|CF|CUBEFuse (6-100 A)<br>Non-indicating time-delay,<br>Low-Peak CUBEFuse (1-100 A)|600 Vac/<br>300 Vdc|9000|
||Non-indicating fast-acting<br>CUBEFuse (1-100 A)|600 Vac/dc|2147|
- Listed to UL and cULus
- Open fuse indication lamp per pole speeds troubleshooting
- Additional open fuse indication can be provided by using the timedelay indicating CUBEFuse in ratings from 6 to 100 A
- Built-in switch/fuse interlock prevents removing or installing a fuse while energized
- Permanent lockout/tagout and lock-on provision usign a 1/4” lock
## Specifications:
Switch amp ratings and rejection breaks
- 15, 20, 30, 40, 50, 60, 70, 90 and 100 A
## Poles
- 1-, 2- and 3-poles
**==> picture [174 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
Lineside bolt-on bus connector<br>Switch ON and OFF symbols<br>1d<br>Lockout/tagout<br>provision<br>Switch handle<br>Local open fuse indication CCP2B lock on<br>light device (sold as<br>accessory)<br>CUBEFuse base<br>Set screw size:<br>5/64”x3/8”, 8-32<br>Loadside box lug and fork thread<br>terminals Allen wrench size:<br>5/64”<br>**----- End of picture text -----**<br>
## Volts
- 600 Vac (or less)
Lock on device for CCP2B up to 60 amps
- 125 Vdc*
- Switch amp rating and installed fuse amp rating dependent, see catalog number table for details.
## Agency information
- UL 98 Listed, Guide WHTY, File E302370
- cULus to Canadian Standard 22.2 No. 4, Guide WHTY7, File E302370
- RoHS compliant
- CE
## Data sheet no: 1161
|Catalogno.|Description|Compatible CCP2B|
|---|---|---|
|||CCP2B-X-15CF*|
|||CCP2B-X-20CF*|
|CCP2B-60-LOD|Lock on device for select<br>CCP2B bases|CCP2B-X-30CF*<br>CCP2B-X-40CF*<br>CCP2B-X-50CF*<br>CCP2B-X-60CF*|
- *(X = 1,2,3 poles)
- Lock Shackle Size = ¼” dia. max
- Flammability rating of lock on device PA12-GB nylon resin = 94V-0
Eaton.com/bussmannseries
11-36
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## Catalog numbers and ratings
## Box lug conductor data
**==> picture [562 x 579] intentionally omitted <==**
**----- Start of picture text -----**<br>
Accepts AWG Torque<br>Catalog Voltage CUBEFuse Hp ratings Wire type range Class Quantity N•m (lb-in)<br>numbers Poles ratings amp range SCCR (Vac)††† 15 to 60 A switches<br>CCP2B-1-15CF 1 347 Vac, 125 Vdc 0.5 Hp @ 120 V 8-184-6 Stranded, Class B to K Single 3.95 2.26 ((3520))<br>600 Vac,<br>CCP2B-2-15CF 2 125 Vdc 1 to 15 1.5 Hp @ 240 V 6-8 Stranded, Class B/C 3.39 (30)<br>3 Hp @ 240 V Stranded, Class K Dual<br>CCP2B-3-15CF 3 600 Vac 5 Hp @ 480 V 10-18 Stranded, Class B 2.26 (20)<br>7.5 Hp @ 600 V 75°C Cu to K<br>347 Vac, 10-18 Solid Single/dual 2.26 (20)<br>CCP2B-1-20CF 1 125 Vdc 0.75 Hp @ 120 V 4-18 Stranded, UL ferrule, Single<br>3.39 (30)<br>CCP2B-2-20CF 2 600 Vac, 125 Vdc 1 to 20 2 Hp @ 240 V 6-18 Class B/C Twin [†]<br>4-18 Stranded, UL Single<br>3 Hp @ 240 V 6-18 ferrule, Class K Twin [†] 2.82 (25)<br>CCP2B-3-20CF 3 600 Vac 7.5 Hp @ 480 V<br>10 Hp @ 600 V 70 to 100 A switches<br>347 Vac, 12-18 2.26 (20)<br>CCP2B-1-30CF 1 125 Vdc 1.5 Hp @ 120 V 10 2.82 (25)<br>CCP2B-2-30CF 2 600 Vac, 125 Vdc 1 to 30 3 Hp @ 240 V 8 Stranded, Class B to K Single 4.52 (40<br>4-6 5.08 (45)<br>5 Hp @ 240 V 1-3 6.21 (55)<br>CCP2B-3-30CF 3 600 Vac 15 Hp @ 480 V<br>10 Hp @ 600 V 3-12 Stranded, Class B Dual 3.95 (35)<br>to K<br>347 Vac,<br>CCP2B-1-40CF 1 125 Vdc 2.0 Hp @ 120 V 12-18 2.26 (20)<br>600 Vac, 10 Single 3.95 (35)<br>CCP2B-2-40CF 2 125 Vdc 1 to 40 3 Hp @ 240 V 1-8 Stranded, UL 4.52 (40)<br>75°C Cu ferrule, Class B/C<br>7.5 Hp @ 240 V 10-18 2.26 (20)<br>CCP2B-3-40CF 3 600 Vac 20 Hp @ 480 V 6-8 Twin† 2.82 (25)<br>10 Hp @ 600 V<br>10-18 Single 2.26 (20)<br>347 Vac, Solid<br>CCP2B-1-50CF 1 125 Vdc* 200 kA 3.0 Hp @ 120 V 10-18 Dual 2.26 (20)<br>600 Vac, AC 8-18 2.26 (20)<br>CCP2B-2-50CF 2 125 Vdc* 1 to 50 5 Hp @ 240 V 1-6 Class K Single 3.39 (30)<br>100 kA 7.5 Hp @ 240 V 3-10 Dual 5.08 (45)<br>CCP2B-3-50CF 3 600 Vac DC 20 Hp @ 480 V 8-18 2.26 (20)<br>10 Hp @ 600 V 1-6 Class K, UL ferrule Single 3.39 (30)<br>347 Vac,<br>CCP2B-1-60CF 1 125 Vdc* 3.0 Hp @ 120 V 6-18 Twin 2.26 (20)<br>600 Vac, † Two stranded conductors placed in one UL Listed twin ferrule.<br>CCP2B-2-60CF 2 125 Vdc* 1 to 60 7.5 Hp @ 240 V<br>Dimensions — in (mm)<br>7.5 Hp @ 240 V<br>CCP2B-3-60CF 3 600 Vac 20 Hp @ 480 V10 Hp @ 600 V (76)3.03.0 2.0 (25)1.01.0 (13)0.50.5 (69)2.72.7<br>347 Vac, (51)<br>CCP2B-1-70CF 1 125 Vdc 3.0 Hp @ 120 V<br>600 Vac,<br>CCP2B-2-70CF 2 125 Vdc 1 to 70 7.5 Hp @ 240 V<br>15 Hp @ 240 V<br>CCP2B-3-70CF 3 600 Vac 30 Hp @ 480 V<br>40 Hp @ 600 V 3.9<br>(99) 15-60 A<br>347 Vac,<br>CCP2B-1-90CF 1 125 Vdc** 5.0 Hp @ 120 V<br>600 Vac,<br>CCP2B-2-90CF 2 125 Vdc** 1 to 90 10 Hp @ 240 V<br>20 Hp @ 240 V<br>CCP2B-3-90CF 3 600 Vac 50 Hp @ 480 V 2.9<br>347 Vac, 40 Hp @ 600 V (Ø 5.1)Ø 0.2Ø 0.2 (76)3.03.0 (51)2.02.0 (25)1.01.0 (0.8)0.030.03 (70)2.7(73)2.7(73)(73)<br>CCP2B-1-100CF 1 125 Vdc** 5.0 Hp @ 120 V<br>0.54<br>600 Vac, (14)<br>CCP2B-2-100CF 2 125 Vdc** 1 to 100 10 Hp @ 240 V<br>20 Hp @ 240 V<br>CCP2B-3-100CF 3 600 Vac 50 Hp @ 480 V<br>40 Hp @ 600 V<br>Ø 0.2<br>(Ø 5.1)<br>switches<br>Disconnect<br>**----- End of picture text -----**<br>
**==> picture [256 x 271] intentionally omitted <==**
**----- Start of picture text -----**<br>
(76)3.03.0 2.0 (25)1.01.0 (13)0.50.5 (69)2.72.7<br>(51)<br>3.9<br>(99) 15-60 A<br>2.9<br>(Ø 5.1)Ø 0.2Ø 0.2 (76)3.03.0 (51)2.02.0 (25)1.01.0 (0.8)0.030.03 (70)2.7(73)2.7(73)(73)<br>0.54<br>(14)<br>5.3 70-100 A<br>(133)<br>3.4<br>(86)<br>Ø 0.2<br>(Ø 5.1)<br>**----- End of picture text -----**<br>
- 1 and 3 A indicating CUBEFuse not available. Correct fit with CCP2B disconnect requires indicating CUBEFuse with date code R38 or later.
- †† Not for use with motors.
- ††† Indicating or non-indicating time-delay CUBEFuse only.
- 125 Vdc for installed fuse amp ratings up to 40 A. 24 Vdc for installed fuse amp ratings from 45 to 60 A.
- ** 125 Vdc for installed fuse amp ratings up to 80 A, 24 Vdc for installed fuse amp ratings from 90 to 100 A.
For details on the CCP2B and its use in the Quik-Spec Coordination Panelboard, see data sheet no. 1160.
Data sheet no: 1161
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-37
**11 — Disconnect switches**
## Compact Circuit Protector (cat. no. CCP2)
For use with Class CC, Supplemental and IEC 10x38 mm fuses
CCP2 switch
CCP2 right front rotary switch
CCP2 right side rotary switch
**==> picture [257 x 200] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Class CC and midget CCP contents|Section page|
|Description and specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-40|
|Catalog numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|41|
|Conductor information and available fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|42|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|42|
|Accessories|
|Multi-wire lug kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|43|
|Selector and pistol handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|44|
|NFPA 79 compliant handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|44|
|Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|44|
|Auxiliary contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|45|
|PLC fuse monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46-47|
|How to order tables|
|Clockwise rotary operated switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-49|
|Switches only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|50|
|Counterclockwise rotary operates switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|51|
**----- End of picture text -----**<br>
CCP2 left front rotary switch
CCP2 left side rotary switch
Eaton.com/bussmannseries
11-38
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## Catalog symbols
**==> picture [264 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Symbol Fuse type Description<br>**----- End of picture text -----**<br>
|CCP2-(poles)-30CC<br>CCP2-(poles)-30M|Class CC<br>UL sup./IEC 10x38|Switch only|
|---|---|---|
|CCP2-1-DCC<br>CCP2-1-DCM|Class CC Vdc<br>UL sup./IEC 10x38 Vdc|1-pole switch only|
|CCP2R-(pole)-30CC<br>CCP2R-(pole)-30M<br>CCP2RL-(pole)-30CC<br>CCP2RL-(pole)-30M<br>CCP2S-(pole)-30CC<br>CCP2S-(pole)-30M|Class CC<br>UL sup./IEC 10x38<br>Class CC<br>UL sup./IEC 10x38<br>Class CC<br>UL sup./IEC 10x38|Right front rotary switch<br>Left front rotary switch<br>Right side rotary switch|
|CCP2SL-(pole)-30CC<br>CCP2SL-(pole)-30M|Class CC<br>UL sup./IEC 10x38|Left side rotary switch|
## Description
The revolutionary next generation Bussmann™ series Compact Circuit Protector (cat. no. CCP2) fused disconnect switch is 3/5 the footprint of a traditional fusible switch and provides up to a high 200 kA Short-Circuit Current Rating (SCCR) to help improve panel and assembly SCCR.
The 35 mm DIN-Rail mount CCP is available in a variety of configurations to meet many application needs including rotary operation.
Application flexibility is extended with an optional multi-wire lug kit, with finger-safe shrouds, that provides three additional wire ports on each pole for power distribution applications.
Other accessories include a PLC interface device for open fuse monitoring and NO/NC auxiliary contacts that easily integrate into many monitoring systems.
Front and side rotary operated versions are easily applied for through-the-door or through the left or right side operation to enhance safety.
## Ratings
- Volts
- 600 Vac (UL[®] Class CC)
- 240 Vac (UL Supplemental)
- 400 Vac (IEC 10x38 mm)
- 80 Vdc (DC Class CC, DC UL Supplemental/IEC)
- Amps
- 30 A (UL)
- 32 A (IEC)
- SCCR
- 200 kA (UL Class CC)
- 10 kA (UL Supplemental)
- 120 kA (IEC 10x38 mm max)
- UL Supplemental and IEC 10x38 mm fuse versions
- UL 508 Listed, Guide NRNT, File E320230
- cULus Certified 22.2 No. 14-05
- IEC 60947-3 AC-23A
- DC voltage UL Class CC version (CCP2-1-DCC)
- UL 508 Listed, cULus 22.2, No. 1405
- DC IEC 10x38 version (CCP2-1-DCM)
- IEC 60947-3, DC-23A
- RoHS compliant
- CE
## Conductors/terminals
- 75°C Cu/Al, see conductor tables for size, type and torque information
- Box lug, single/dual conductor
- Fork terminal suitable for line, load or accessory connection
- Multi-wire lug kit — see accessories for details
## Storage and operating temperature
- - 20°C to 75°C (-4°F to 167°F)*
- For fuse performance under or above 25°C, consult fuse performance derating charts in the Bussmann Division publication no. 3002, titled Selecting Protective Devices (SPD)
## Lockout/tagout provisions
> • Switch only — 4 mm lock or Brady pin-out device part number 90850
- Switch with rotary operating mechanism — 1/4” lock
## Minimum enclosure size
- 10” x 8” x 6” (254 x 203 x 152 mm)
## Mounting
- 35 mm DIN-Rail
Local open fuse indication minimum voltage**
- 90 Vac for AC switches
- 12 Vdc for DC switches
- ** Open fuse indication requires an open fuse to be in the CCP2 and the switch in the ON position.
## Accessories
- Multi-wire lug kit with terminal shrouds
- Selector and pistol handles for use with rotary operated switches
- 8 mm shafts for use with selector and pistol handles
- Auxiliary contacts
- PLC fuse monitor
- 20 kA (DC Class CC/UL)
- 10 kA (DC UL Supplemental/IEC)
## Poles
- 1-, 2- and 3-poles catalog number dependent
## Agency information
- UL Class CC fuse versions
- UL 98 Listed, Guide WHTY, File E302370
- cULus to Canadian Standard 22.2 No. 4-04, UL Guide WHTY7, File 302370
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-39
## **11 — Disconnect switches**
## Features
- Extremely compact (18 mm wide per pole ) design
- High SCCR up to 200 kA (UL Class CC) and 120 kA (IEC)
- Disconnect rated for load isolation
- Full voltage rated up to 600 Vac or 80 Vdc
- UL 98 Listed Class CC version is horsepower rated and suitable for branch circuit protection and disconnect
- IEC 10x38 version complies with IEC 60947-3 and suitable for branch circuit protection and disconnect
> • Suitable for global installations, the switches comply with UL, cULus and IEC standards accepting UL Class CC, Supplemental or IEC aM and gG/gL fuses
- Open fuse indication
- Standard local open fuse indicating light for each pole
- Optional PLC fuse monitor can be utilized to signal a PLC and open a contactor to de-energize all phases, if required
> • IP20 finger-safe with 10 AWG (6 mm[2] ) or larger wire (box lug terminals only)
- Built-in switch interlock prohibits removing the fuse under load
- Padlockable handle for lockout/tagout
- 4 mm lock for switch only
- 1/4” lock for rotary operated switches
- Rotary operated versions provide for through-the-door and through-the-side operation flexibility and enhanced safety with:
- Right front switch operation
- Left front switch operation
Right front rotary operated CCP2 switch with PLC fuse monitor.
- Right side switch operation
- Left side switch operation
> • Optional selector and pistol handles available for use with rotary operated versions
## Rotary operating switch versions
- Multi-wire lug kit with terminal shrouds allows for power distribution to multiple loads. Each lug has three ports rated for single and dual wires (see lug kit in accessories for conductor and torque details).
**==> picture [259 x 201] intentionally omitted <==**
**----- Start of picture text -----**<br>
Switch handle<br>(ganged on 2- and<br>Open fuse 3-pole versions)<br>indicating light<br>Fuse access door<br>R CE) rd A<br>Fork terminal<br>Box lug terminal<br>Lockout/tagout y : 3 “<br>provision<br>**----- End of picture text -----**<br>
**==> picture [246 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
Left front rotary switch Right front rotary switch<br>Clockwise operating handles Clockwise operating handles<br>I, [oR i mm 7<br>A) \ i al cal 1 =<br>Right side rotary switch CORR Left side rotary switch —<br>Clockwise operating handles Counterclockwise operating han-<br>dles<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
11-40
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## Catalog numbers
**==> picture [562 x 415] intentionally omitted <==**
**----- Start of picture text -----**<br>
Max horsepower rating (Vac)<br>Wire type/<br>Catalog no. Poles Description Amps Volts SCCR 120 240 480 600 size*<br>Class CC<br>CCP2-1-30CC 1 347 Vac 1/2 — — —<br>CCP2-2-30CC 2 Switch only — 2 — —<br>600 Vac<br>CCP2-3-30CC 3 3/4 3 5 7.5<br>CCP2R-2-30CC 2 Switch with right 600 Vac — 2<br>CCP2R-3-30CC 3 front rotary operation 3/4 3 5 7.5 75°C Cu/Al<br>CCP2RL-2-30CC 2 Switch with left front 30 A 200 kA — 2 — — 18-4 AWG<br>600 Vac<br>CCP2RL-3-30CC 3 rotary operation 3/4 3 5 7.5 Fork terminal [††]<br>CCP2S-2-30CC 2 Switch with right side 600 Vac — 2 — —<br>CCP2S-3-30CC 3 rotary operation 3/4 3 5 7.5<br>CCP2SL-2-30CC 2 Switch with left side — 2 — —<br>600 Vac<br>CCP2SL-3-30CC 3 rotary operation 3/4 3 5 7.5<br>UL Supplemental and IEC 10x38 mm<br>CCP2-1-30M 1<br>CCP2-2-30M 2 Switch only<br>CCP2-3-30M 3<br>CCP2R-2-30M 2 Switch with right<br>CCP2R-3-30M 3 front rotary operation 75°C Cu/Al<br>UL 240 Vac†<br>CCP2RL-2-30M 2 Switch with left front IEC 32 A**UL 30 A UL 10 kA†IEC 120 kA† — — — — 18-4 AWG<br>CCP2RL-3-30M 3 rotary operation IEC 400 Vac† Fork terminal [††]<br>CCP2S-2-30M 2 Switch with right side<br>CCP2S-3-30M 3 rotary operation<br>CCP2SL-2-30M 2 Switch with left side<br>CCP2SL-3-30M 3 rotary operation<br>Single-pole DC switches<br>CCP2-1-DCC 1 UL Class CC 30 A 80 Vdc [†] 20 kA [†] — — — — 75°C Cu/Al<br>UL supplemental 30 A 18-4 AWG<br>CCP2-1-DCM 1 80 Vdc [†] 10 kA [†] — — — —<br>IEC 10x38 32 A** Fork terminal [††]<br>switches<br>Disconnect<br>**----- End of picture text -----**<br>
* See box lug terminal conductor data table for details.
** 32 A Class aM, 25 A Class gG.
† SCCR may be lower, refer to installed fuse data sheet for interrupting rating at applied voltage.
†† Fork terminal with a 4.3 mm gap for a #8-32 stud, 30 A max, insulated flange, wire size 12-10 AWG.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-41
## **11 — Disconnect switches**
Box lug terminal conductor data
|Type|AWG<br>range<br>4-18|Class<br>Stranded,Class B to K|Quantity<br>Single|Torque<br>N•m(lb-in)<br>2.26(20)|
|---|---|---|---|---|
||6-8|Stranded,Class B/C|Dual|3.39(30)|
||6-8|Stranded,Class K|Dual||
||10-18|Stranded,Class B to K||2.26 (20)|
|Cu|10-18|Solid|Single/dual||
||4-18<br>6-18|Stranded, UL ferrule, Class B/C|Single<br>Twin†|3.39 (30)|
||4-18|Stranded, UL ferrule, Class K|Single|2.82 (25)|
||6-18||Twin†||
||4-8||Single|2.26 (20)|
|Al|6|Stranded||2.82 (25)|
||||Dual||
||8|||2.26 (20)|
† Two stranded conductors placed in one UL Listed twin ferrule.
Available Bussmann series fuses
|Fuse<br>class|Type/description|Volts|Data<br>sheet<br>no.|
|---|---|---|---|
||LP-CC time-delay|600 Vac/300 Vdc*|1023|
|CC|FNQ-R time-delay|600 Vac/300 Vdc|1014|
||KTK-R fast-acting|600 Vac|1015|
||FNM time-delay|250 Vac|2028|
||FNQ time-delay|500 Vac|1012|
|M|KTK fast-acting|600 Vac|1011|
||BAF fast-acting|250 Vac|2011|
|gG/gL|KLM fast-acting<br>C10G|600 Vac/dc<br>500 V (400 V@32 A)|2020<br>720115|
|aM|C10M|500 V (400 V@20@25 A)|720115|
- 1/2 to 2-1/2 and 20 to 30 A are 300 Vdc, 2-8/10 to 15 A are 150 Vdc.
## Dimensions – mm (in)
Switch
**==> picture [204 x 165] intentionally omitted <==**
**----- Start of picture text -----**<br>
53<br>49 35 2.1<br>1.9 18 1.4<br>0.7<br>93<br>3.7<br>80<br>3.1<br>**----- End of picture text -----**<br>
Left front and right front rotary switches
**==> picture [230 x 306] intentionally omitted <==**
**----- Start of picture text -----**<br>
78<br>3.999 3.1 2.153 35<br>49 1.4 18<br>1.9 0.7<br>93<br>3.7<br>80<br>3.1<br>99 78<br>[3.9] 53 [3.1]<br>[1.9]49 [0.7]18 [1.4]35 [2.1]<br>93<br>93 [3.7]<br>[3.7]<br>80<br>[3.1]<br>**----- End of picture text -----**<br>
Left side and right side rotary switches
**==> picture [213 x 159] intentionally omitted <==**
**----- Start of picture text -----**<br>
78<br>3.1 53<br>2.1 35<br>1.4 18<br>1.949 0.7<br>93<br>3.7<br>80<br>3.1<br>**----- End of picture text -----**<br>
**==> picture [203 x 154] intentionally omitted <==**
**----- Start of picture text -----**<br>
78<br>53 3.1<br>1.949 0.718 1.435 2.1<br>93<br>3.7<br>80<br>3.1<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
11-42
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## Multi-wire lug kit
Installed on CCP2-3-xx
Catalog number
- CCP2-MW1-3
## Description
The multi-wire lug kit permits expanding each box lug terminal on the switch into a three-port terminal for power distribution applications.
Each multi-wire lug kit comes with three (3) three-port lugs and three terminal shrouds. Shrouds provide finger-safe protection when properly installed.
Lugs may be mounted on either the loadside or lineside to meet various application needs.
Ports on any one lug accept any conductor combination listed, e.g., one of the three ports may have dual 14 AWG wires and the other two ports single 10 AWG wires.
## Ratings
- Volts 600 V
- Amps 60 A max
- SCCR 200 kA
## Agency information
Multi-wire lugs mount in switch box lug terminals to provide three additional wire ports per pole. Lugs can be mounted on the switch lineside or loadside. Each multi-wire lug kit comes with three lugs and three shrouds.
Wire insulation strip lengths
- UL Recognized (lug only)
- RoHS compliant
Storage and operating temperature
- - 20°C to 75°C (-4°F to 167°F)
Multi-wire lug conductor information
- 75°C Cu/AL
1/8” Allen head screw 1 = 11/16” 2 = 1-1/8” 3 = 1-9/16”
- AWG size and quantity per port - see table below
|Type<br>AWG<br>range|Class|Quantity|Torque<br>N•m (lb-in)|
|---|---|---|---|
|Cu/Al<br>4-6<br>8|Stranded, Class B/C|Single|3.95 (35)<br>2.82 (25)|
|10-14|Stranded, Class B/C|Single/dual*|2.26 (20)|
|Cu<br>10-14|Solid|Single|2.26 (20)|
|8|||2.82 (25)|
|10-14|UL ferrule, Class B to K|Single/twin†|2.26 (20)|
Strip back wire insulation to the lengths as indicated in the illustration above and the table below.
|Lug port|Lug port<br>Strip wire insulation back (inch)|Strip wire insulation back (inch)|Strip wire insulation back (inch)|Strip wire insulation back (inch)|Strip wire insulation back (inch)|
|---|---|---|---|---|---|
|1|||11/16|||
|2|||1-1/8|||
|3|||1-9/16|||
* Dual wire to be same size and type. † Two stranded conductors placed in one UL Listed twin ferrule. CCP2 box lug torque for multi-wire lug • 4.52 N•m (40 lb-in) Terminal shroud accessory Terminal shrouds are available without multi-wire terminals. Catalog no. Description CCP2-TS1-3 Pack of three ~~ee~~
Wiring versatility is provided by single/dual rated box lug terminals on the switch, or by the three-port multi-wire lug kit that’s also single/dual wire rated.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-43
**11 — Disconnect switches** ~~TA~~
Selector and pistol handles
## Selector handles
## Catalog symbol
- CCP2-H4X-_
## Description
Selector and pistol handles for use with any 2- and 3-pole CCP2 rotary operated switch. Both selector and pistol handles are available in black/grey and red/yellow colors and clockwise/counterclockwise operating modes. Applying clockwise and counterclockwise operation depends upon the CCP2 rotary switch configuration. Installation requires an 8 mm shaft (ordered separately).
Each handle is rated NEMA 4X and capable of accepting up to three (3) 1/4” diameter shank locks for lockout/tagout in the OFF position. They can also be field configured for lock-on.
In application, only the clockwise operating handles in combination with either the left front or right front rotary switches provide a door interlock means to ensure the enclosure door remains shut during lockout/tagout or lock-on. Both clockwise and counterclockwise operating handles when mounted on the enclosure’s left or right side do NOT provide a door interlock means.
See the catalog number table below for applicable rotary switch, handle and shaft combinations.
Pistol handles it &
Handle shafts
## Agency information
- UL Listed, Guide DIHS, File E140305
- NEMA 4X rating
- RoHS compliant
- CE
Storage and operating temperature
- -20°C to 75°C (-4°F to 167°F)
## Packaging
- Each handle is packaged individually
## Handle shafts
## Catalog symbol
- CCP2-SH1-_
## Description
NFPA 79 compliant handle
## Catalog number
- CCP2-NFPA-1
## Description
NFPA 79 compliant handle mounts on the shaft of front rotary operated switch installations and provide a lockout means independent of the door position.
Eight millimeter square shafts available in 290 and 490 millimeter (11.5 and 19.3 inch) lengths. Shafts are indexed to ensure handle/ switch orientation for correct operation. Shafts are cut to length when installed.
## Packaging
> • Each shaft is packaged separately
|For these switch<br>catalognumbers<br>Description/operation<br>Order these handle catalog numbers<br>(description)<br>Order either shaft catalognumber<br>~~eee~~|For these switch<br>catalognumbers<br>Description/operation<br>Order these handle catalog numbers<br>(description)<br>Order either shaft catalognumber<br>~~eee~~|For these switch<br>catalognumbers<br>Description/operation<br>Order these handle catalog numbers<br>(description)<br>Order either shaft catalognumber<br>~~eee~~|For these switch<br>catalognumbers<br>Description/operation<br>Order these handle catalog numbers<br>(description)<br>Order either shaft catalognumber<br>~~eee~~|
|---|---|---|---|
|CCP2R-(pole)-30CC<br>CCP2R-(pole)-30M|Right front rotary, clockwise|• CCP2-H4X-B1 (selector, black/grey)||
|CCP2RL-(pole)-30CC<br>CCP2RL-(pole)-30M|Left front rotary, clockwise|• CCP2-H4X-R1(selector, red/yellow)<br>• CCP2-H4X-B2 (pistol, black/grey)||
|CCP2S-(pole)-30CC<br>CCP2S-(pole)-30M|Right side rotary, clockwise|• CCP2-H4X-R2 (pistol, red/yellow)|• CCP2-SH1-290 (11.5”/290 mm)<br>• CCP2-SH1-490 (19.3”/490 mm)|
|CCP2SL-(pole)-30CC||• CCP2-H4X-B1L (selector, black/grey)||
|CCP2SL-(pole)-30M|Left side rotary, counterclockwise|• CCP2-H4X-R1L (selector, red/yellow)<br>• CCP2-H4X-B2L (pistol, black/grey)||
|||• CCP2-H4X-R2L (pistol, red/yellow)||
Eaton.com/bussmannseries
11-44
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## Auxiliary contacts
## Catalog number
## Installed on a CCP2-3-xx
Note: CCP2-AUX CANNOT be mounted on the right front and right side rotary operated versions.
- CCP2-AUX
## Description
NO+NC contact output to indicate the switching mechanism status on the CCP2. A single unit can be mounted on any 1-, 2- or 3-pole CCP2 switch and the left front/left side rotary operated switches.
## Ratings
- Amps up to 5 A
- Volts up to 240 Vac
> • NC/NO contacts are closed/open when the CCP2 switch is in the “ON” position (closed)
Dimensions — in
Description Max per CCP2* Signal output Auxiliary contacts NO+NC 1 per CCP2 5 A / 240 Vac for switch status (1-, 2- or 3-pole) ~~Pe~~
- The CCP2-AUX CANNOT be mounted on the right front and right side rotary operated versions. De-energize all circuits and follow all prevailing safety procedures before installing or removing the CCP2-AUX.
## Agency information
- UL 98 Recognized, Guide WHTY2, File E155130
- cURus to Canadian Standard 22.2 No. 4-04
- IP20 finger-safe in installed state
- RoHS compliant
- CE
## Wiring
**==> picture [263 x 180] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.8<br>4<br>°<br>fe) fe)<br> 2.6 STRIP<br>33 NO 34 NO 1.9<br>° oo<br>:<br>41 NC 42 NC<br>©<br> 3.7 0.19<br> 0.3<br>SPL<br>**----- End of picture text -----**<br>
- 75°C Cu, 20-16 AWG (0.5 to 1.5 mm[2] ) wire
- Torque 0.56 N•m (5 lb-in)
## Packaging
- The CCP2-AUX is packaged individually
## Installation technique
- Mounts on the CCP2’s right side ONLY and mechanically interlocks with the CCP2 switch handle with provided hardware. The CCP2-AUX CANNOT be mounted on the right front and right side rotary operated versions.
## Storage and operating temperature
- -20°C to 75°C (-4°F to 167°F)
CCP2-AUX auxiliary contacts mounted on a 3-pole CCP2 switch.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-45
**11 — Disconnect switches**
## PLC fuse monitor
## Catalog number
Wiring
- For power, signal and ground connections use shielded twisted pair 22-24 AWG (0.34-0.25 mm[2] ) 300 V rated wire
- CCP2-PLC-IND
## Description
A resettable three-phase fuse monitor that integrates with the I/O card in a Programmable Logic Controller (PLC). A single unit can be mounted on any 1-, 2- or 3-pole CCP2 switch and the right front/ right side rotary operated switches. A single unit monitors up to three phases. When used on 1- and 2-pole switches unused conductor(s) are removed after installation.
The CCP2-PLC-IND CANNOT be mounted on the left front/left side rotary operated versions or if the multi-wire lug kit is installed.
## Ratings
- Signal output to PLC*
- +24 Vdc, 10 mA max
- Output signals
- Digital 0 Vdc (low), 24 Vdc max (high)
- 0 Vdc Low – fuse is good
- 24 Vdc High – fuse has opened
- When the fuse opens, the output signal is sent high and will remain high until the unit is reset.
## Packaging
- The CCP2-PLC-IND is packaged individually
- Includes 0.110” (2.8 mm) quick connects for power, signal and ground connections
## Installation technique
- Mounts on the left side ONLY of the CCP2 and mechanically interlocks with the CCP2 switch handle with hardware provided. The CCP2-PLC-IND CANNOT be mounted on the left front/ left side rotary operated versions or if the multi-wire lug kit is installed.
## IP20 rating — yes
## Storage and operating temperature
- -20°C to 75°C (-4°F to 167°F)
## PLC programming
- The CCP2-PLC-IND signal line is designed to provide a digital input to a PLC I/O card. In this case, a Programmable Logic Control program must be written to properly interpret the input signal to the PLC. The PLC program should check for consecutive high signals before taking action on a critical process.
Installed on a CCP2-3-xx
## Emissions and immunity testing
- IEC 60947-1: Voltage Switchgear and Control Gear
- IEC 61000-6-2: Electromagnetic Compatibility (EMC)
- IEC 61000-4-2: Electrostatic Discharge Immunity - Test at level 3 (6 kV-Contact Discharge) and level 2 (4 kV-Air Discharge)
- IEC 61000-4-3: Electromagnetic Compatibility - Radiated, Radiofrequency, Electromagnetic Field Immunity test at level x (20 V/m)
- IEC 61000-4-4: Electromagnetic Compatibility - Testing and Measurement Techniques at level 3 (± 2 kV - Power Port and ±1 kV - I/O Ports)
- IEC 61000-4-5: Electromagnetic Compatibility - Surge Immunity test at level 4 (±4 kV)
- IEC 61000-4-6: Immunity to Conducted Disturbances at level 3 (10 V)
CCP2-PLC-IND mounted on a 3-pole switch and using the fork terminals. When mounted on a 2- or 1-pole switch, remove unused leads.
Note: The CCP2-PLC-IND CANNOT be mounted on the left front/left side rotary operated versions or if the multi-wire lug kit is installed.
|Description|Max per<br>CCP2**|Signal output<br>to PLC|Min. circuit<br>volts|
|---|---|---|---|
|Wired remote fuse<br>indication for PLC<br>applications|1 per CCP2<br>(1, 2- or 3-pole)|24 Vdc/ 10 mA|100 Vac|
- ** The CCP2-PLC-IND CANNOT be mounted on the left front/left side rotary operated versions or if the multi-wire lug kit is installed.
De-energize all circuits and follow all prescribed safety procedures before installing or removing the CCP2-PLC-IND.
## Agency information
- UL 98 Recognized, Guide WHTY2, File E155130
- cURus to Canadian, Standard 22.2 No. 4-04
## Local indication
- Two distinct LEDs indicate unit power (green) and open fuse (red). Open fuse LED is resettable upon fuse replacement and actuating the reset switch.
CCP2-PLC-IND fuse monitor mounted on a right front rotary operated switch.
Eaton.com/bussmannseries
11-46
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
PLC wiring schematic
PLC power supply
PLC fuse monitor
CCP2-PLC-IND connections from a CCP2-3-xx to a remote monitoring device
**==> picture [207 x 45] intentionally omitted <==**
**----- Start of picture text -----**<br>
+24 Vdc +24 Vdc<br>0 Vdc/Gnd 0 Vdc/Gnd<br>Signal<br>10 mA max.<br>**----- End of picture text -----**<br>
The PLC fuse monitor needs to be powered by the same +24 Vdc and ground (0 Vdc/Gnd return) terminals that feed the PLC input card.
**==> picture [244 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuit monitoring leads from<br>CCP2-PLC-IND to CCP2<br>(100 – 600 Vac) 1 ee<br>Circuit monitoring<br>leads from PLC or<br>remote monitoring<br>device.<br>_ Ee<br>**----- End of picture text -----**<br>
If it is not, it may improperly signal.
+24 Vdc If feeding multiple 0 Vdc/Gnd PLC fuse monitors from different power supplies, PLC there must be multiple input cards being powered input card by those same power supplies as well.
Connection from CCP2-PLC-IND to CCP2-3-xx
**==> picture [245 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power lead Lead from CCP2-PLC-IND<br>**----- End of picture text -----**<br>
Leads from CCP2-PLC-IND are connected to the fork terminals as shown.
Note: When monitoring a 1- or 2-pole switch, remove unused leads.
## Dimensions — in
**==> picture [414 x 165] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.8<br>Pin interlocks with<br>CCP2 switch handle<br>i<br>om es So, 2 2<br> 2.6 1.9<br>| rl) 6<br>Cc -{— a, IS)<br> 3.7 0.3<br>ON RESET STATUS +24vDC +24vDC GND SIG<br>1L1 2T1<br>2<br>3L2<br>4T<br>5L3 6T3<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-47
**11 — Disconnect switches** ~~<0~~
Class CC and UL Supplemental (IEC 10x38) clockwise rotary switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no. Switches Amps Poles Right front rotary CCP2R-2-30CC 2 ~~Pe Po~~ CCP2R-3-30CC 3 CCP2R-2-30M 30 2 CCP2R-3-30M 3 ~~SrPo Se~~ Left front rotary CCP2RL-2-30CC 2 CCP2RL-3-30CC 3 30 CCP2RL-2-30M 2 CCP2RL-3-30M 3 ~~—————— —— oe~~ Right side rotary CCP2S-2-30CC 2 CCP2S-3-30CC 3 30 CCP2S-2-30M 2 CCP2S-3-30M 3 ~~——————~~ And Rotary handles Description NEMA rating CCP2-H4X-B1 Selector handle — black/grey CCP2-H4X-R1 Selector handle — red/yellow 4X CCP2-H4X-B2 Pistol handle — black/grey Cals ~~a ee~~ CCP2-H4X-R2 Pistol handle — red/yellow ~~a ee~~ And Shafts (8 mm) Length CCP2-SH1-290 290 mm CCP2-SH1-490 490 mm ~~I ——~~ NFPA 79 compliant Color handle CCP2-NFPA-1 Red ~~a~~ And Lug kits Description CCP2-MW1-3 3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
Eaton.com/bussmannseries
11-48
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
And Terminal shrouds Description CCP2-TS1-3 Pack of 3 ~~qo~~ Auxiliary contacts Description — cannot be used on right front or right side operated switches CCP2-AUX NO + NC, 5 A / 240 V ~~i___~~ PLC fuse monitor Description — Cannot be used on left front operated switches CCP2-PLC-IND Signal output 24 Vdc / 10 mA ~~tT~~
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-49
**11 — Disconnect switches**
Class CC and UL Supplemental (IEC 10x38) Switches
For a complete assembly, select from the following required and optional components, and accessories.
**==> picture [536 x 679] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog no.<br>Switches Amps Poles<br>Switch<br>CCP2-1-30CC 1<br>CCP2-2-30CC 2<br>CCP2-3-30CC 3<br>30<br>CCP2-1-30M 1<br>CCP2-2-30M 2<br>CCP2-3-30M 3<br>———=<br>And<br>Lug kits Description<br>CCP2-MW1-3 3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3<br>jC<br>And<br>Terminal shrouds Description<br>CCP2-TS1-3 Pack of 3<br>Auxiliary contacts Description<br>CCP2-AUX NO + NC, 5 A / 240 V<br>i<br>PLC fuse monitor Description<br>CCP2-PLC-IND Signal output 24 Vdc / 10 mA<br>—a<br>11-50 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018 Eaton.com/bussmannseries<br>Required<br>Optional<br>Accessories<br>**----- End of picture text -----**<br>
**Disconnect switches — 11**
|Required||Catalog no.|Catalog no.|Catalog no.|
|---|---|---|---|---|
|||Switches|Amps|Poles|
|||Left side rotary|||
||~~—————~~<br>~~fF~~<br>~~|~~<br>~~|~~|CCP2SL-2-30CC<br>~~—————~~<br>~~fF~~|30<br>~~—————~~|2<br>~~—————~~<br>~~PO~~|
|||CCP2SL-3-30CC<br>~~—————~~<br>~~fF~~<br>~~|~~||3<br>~~—————~~<br>~~PO~~<br>~~PO~~|
|||CCP2SL-2-30M<br>~~—————~~<br>~~fF~~<br>~~|~~<br>~~|~~||2<br>~~—————~~<br>~~PO~~<br>~~PO~~<br>~~Po~~|
|||CCP2SL-2-30M<br>~~—————~~<br>~~|~~<br>~~|~~||2<br>~~—————~~<br>~~PO~~<br>~~Po~~|
||~~|~~<br>~~oC~~<br>ler<br>~~ZZ~~|And<br>~~|~~<br>~~Po~~<br>~~oC—~~|||
|||Rotaryhandles<br>~~oC~~|Description<br>~~oC—~~|NEMA rating|
|||CCP2-H4X-B1L<br>~~oC~~|Selector handle — black/grey<br>~~oC—~~|4X<br>~~——~~|
|||CCP2-H4X-R1L<br><br>~~ee~~|Selector handle — red/yellow<br>~~—~~||
|||CCP2-H4X-B2L<br>~~ee~~|Pistol handle — black/grey||
|||CCP2-H4X-R2L<br>~~ee~~<br>~~ee~~<br>~~ZZ~~|Pistol handle — red/yellow<br>~~ee~~<br>~~ZZ~~<br>~~——~~||
||~~ZZ~~|And<br>~~ZZ~~<br>~~——~~|||
|||Shafts (8 mm)<br>~~ZZ~~|Length<br>~~ZZ~~<br>~~——~~||
|||CCP2-SH1-290<br>~~ZZ~~|290 mm<br>~~ZZ~~<br>~~——~~||
|||CCP2-SH1-490<br>~~ZZ~~|490 mm<br>~~ZZ~~<br>~~——~~||
|And<br>~~ZZ~~<br>~~——~~<br>~~ee~~|||||
|Optional||Lug kits|Description||
|||CCP2-MW1-3|3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3||
|And<br>~~|~~|||||
|Accessories||Terminal shrouds|Description||
|||CCP2-TS1-3|Pack of 3||
|||Auxiliarycontacts|Description —mounts on right side||
|||CCP2-AUX|NO + NC, 5 A / 240 V||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-51
**11 — Disconnect switches**
CCPLP UL 98 Listed low profile Compact Circuit Protector
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
The revolutionary Bussmann series low profile Compact Circuit Protector (CCPLP) is a UL 98/508 Listed fused disconnect switch. This front panel mount switch is available in 1-, 2- and 3-pole versions, and has the smallest footprint of any fused disconnect switch. It features an SCCR up to 200 kA to help improve equipment SCCR.
## Four fuse types
The CCPLP is available for UL Class CC and G, UL supplemental (13/32” x 1-1/2”) and IEC 10x38 mm fuses.
Class CC and G versions are easily selectively coordinated with the upstream Bussmann series CUBEFuse™ using published fuse ampacity ratio tables.
## Design/application flexibility
## Poles
## 1-, 2- and 3-pole factory configured*
* 2- and 3-pole versions supplied as ganged switches with phase barriers.
## Agency information
- Class G fuse versions
- UL 98 Listed, Guide WHTY, File E302370
- IEC 60947-3 AC-23A
- Class CC fuse versions
- UL 98 Listed, Guide WHTY, File E302370
- cULus to Canadian Standard 22.2 No. 4-04, Guide WHTY7, File E302370
- IEC 60947-3 AC-23A
- UL supplemental and IEC 10x38mm fuse versions
- UL 508 Listed, Guide NRNT, File E320230
- cULus Listed to Canadian Standard 22.2 No. 14-05, Guide NRNT7, File E320230
- IEC 60947-3 AC-23A
The CCPLP is easily integrated into many panel designs and provides a high SCCR alternative to low profile circuit breakers on the market.
## Ratings
- Volts
- 600 Vac (Class CC up to 30 A, Class G 20 A)
- 550 Vac (10x38mm IEC Class aM 0.16-16 A)
- RoHS compliant
- CE
## Safety
- Finger-safe IP20 from panel front
## Mounting
- 500 Vac (10x38mm IEC Class gG 0.5-25 A)
- 400 Vac (10x38mm IEC Class aM 20-32 A, gG 32 A)
- 240 Vac (13/32” x 1-1/2” UL supplemental 30 A)
- Amps
- Up to 30 A (UL)
- Up to 32 A (IEC)
- Front panel mounting with customer supplied M3 screws
## Open fuse indication*
- Local open fuse indication provided for each pole by an orange neon lamp (minimum 90 V)
- Open fuse indication requires an energized, closed circuit with an open fuse in the CCPLP and the switch in the ON position.
- SCCR
- 200 kA (Class CC)
- 120 kA (10x38mm IEC Class gG and aM)
- 100 kA (Class G)
## Lockout/tagout provision
- Brady pin-out device, part number 90844
## Circuit labeling provision
- 10 kA (13/32” x 1-1/2” UL supplemental)
- Frequency 50/60 Hz
- Accepts up to two universal marker labels, catalog number TM26CB
- Impulse voltage 8 kV
Carton quantity
## Terminals and conductors 75°C/90°C Cu
- 12 poles (1-pole: 12 units, 2-pole: 6 units, 3-pole: 4 units)
- Screw terminal, 10-32 phil-slot screw with external tooth lock washer (use with properly rated/UL Listed ring or fork terminal)
- Pressure plate terminal, 10-32 phil-slot screw (single 22-6 AWG solid or stranded)
## Minimum enclosure size
- 6” x 6” x 4” per UL 98 Listing
## Ambient storage and operating temperature
- -20 to 90°C, 85% relative humidity, non-condensing
Data sheet no.10372
Eaton.com/bussmannseries
11-52
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
|||**Disconnect switches —11**<br>Disconnect<br>switches<br>100<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>200<br>0.5<br>—<br>—<br>—<br>—<br>2<br>—<br>—<br>—<br>3<br>4<br>7. 5<br>10<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—|**Disconnect switches —11**<br>Disconnect<br>switches<br>100<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>200<br>0.5<br>—<br>—<br>—<br>—<br>2<br>—<br>—<br>—<br>3<br>4<br>7. 5<br>10<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
|---|---|---|---|
|||||
|||||
|||||
||CCPLP-1-20G-S<br>CCPLP-1-20G-P<br>1<br>600<br>20<br>CCPLP-2-20G-S<br>CCPLP-2-20G-P<br>2<br>CCPLP-3-20G-S<br>CCPLP-3-20G-P<br>3|100||
|||||
||CCPLP-1-30CC-S<br>CCPLP-1-30CC-P<br>1<br>600<br>30<br>CCPLP-2-30CC-S<br>CCPLP-2-30CC-P<br>2<br>CCPLP-3-30CC-S<br>CCPLP-3-30CC-P<br>3|200||
||||Disconnect<br>switches<br>—<br>2<br>—<br>—<br>—<br>3<br>4<br>7. 5<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
|||||
||CCPLP-1-30M-S<br>CCPLP-1-30M-P<br>1<br>240<br>30<br>CCPLP-2-30M-S<br>CCPLP-2-30M-P<br>2<br>CCPLP-3-30M-S<br>CCPLP-3-30M-P<br>3|10||
||||—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||CCPLP-1-30M-S<br>CCPLP-1-30M-P<br>1<br>gG fuses:<br>up to 25 A @ 500 V<br>32 A @ 400 V<br>aM fuses:<br>up to 16 A @ 550 A<br>20-23 A @ 400V<br>CCPLP-2-30M-S<br>CCPLP-2-30M-P<br>2<br>CCPLP-3-30M-S<br>CCPLP-3-30M-P<br>3|120||
|||120||
|||120||
**==> picture [177 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Switch handle (ganged on 2- and 3-pole versions)<br>**----- End of picture text -----**<br>
**==> picture [422 x 243] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse access door Open fuse indicating light<br>Mounting holes for customer<br>supplied M3 screws<br>Lockout/tagout provision*<br>Circuit marking area<br>Phase barrier 10/32 phil-slot screw or<br>pressure plate terminal<br>**----- End of picture text -----**<br>
**==> picture [116 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
* Use Brady pin-out device, P/N 90844<br>**----- End of picture text -----**<br>
## Available Bussmann series fuses
**==> picture [264 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fuse class Catalog symbol<br>**----- End of picture text -----**<br>
|CC|FNQ-R, KTK-R, LP-CC|
|---|---|
|G|SC|
|M|BAF, FNM, FNQ, KLM, KTK|
|gG|C10G|
|aM|C10M|
Data sheet no.10372
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-53
## **11 — Disconnect switches**
## UL 98 fused disconnect switches up to 800 A
Bussmann series UL 98 and UL 489 fused disconnect switches “break” and “make” power circuits ON and OFF load.
The switches employ double break contacts per pole that help ensure complete isolation of the fuse when the switch is in the "OFF" position.
## Agency information
- UL 98, Guide WHTY, File E155130
- UL 489, Guide WJAZ, File E359801
- CSA 22.2 No. 4, File 257020
- Conforms with IEC 60947-3
- NFPA 79
## Features
- Make and break power under load
- Double break by pole
- 30-60 A DIN-Rail or panel mount, 100-800 A panel mount only
- Up to 200 kA short-circuit current rating
- Finger-safe covers
- Compact footprints available
- Defeatable handles automatically re-latch when the panel door is closed
- Most disconnect switches are front, right side, flange or direct handle operable
- NFPA 79 compliant handle kits
## Online resources available at Eaton.com/bussmannseries
- CAD drawings
- Instruction sheets
- UL information
## Available Bussmann series fuses
|Fuse class|Fuse class<br>Catalogsymbol/type|
|---|---|
||LP-CC time-delay,current limiting|
|CC|FNQ-R time-delay|
||KTK-R fast-acting|
||LPJ time-delay,current limiting|
|J|JKS fast-actingfuses|
||DFJ high speed drive fuse|
||KRP-C time-delay,current limiting|
|L|KTU fast-acting|
||KLU time-delay|
||KRP-CL(225-600 A)|
Eaton.com/bussmannseries
11-54
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## UL 98 fused disconnect switches — 30 to 800 A
|||RDF30CC-3||RDF30J-3 / RDF60J-3-COMP|RDF30J-3 / RDF60J-3-COMP|RDF60J-3|RDF60J-3|RDF200J-3||RDF600J-3||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Poles||||||Catalog no.||||||||
|2-pole||—|—|RDF30J-2|RDF60J-2-COMP|RDF60J-2|RDF100J-2|RDF200J-2|RDF400J-2|RDF600J-2|RDF800L-2|||
|3-pole||RDF30CC-3|RDF30J-3-<br>COMP|RDF30J-3|RDF60J-3-COMP|RDF60J-3|RDF100J-3|RDF200J-3|RDF400J-3|RDF600J-3|RDF800L-3|||
|3-pole + neutral<br>4-pole<br>UL standard<br>Fuse class<br>Max fuse/ampacity||RDF30CC-3N<br>—<br>UL 489<br>CC<br>30|RDF30J-3N-<br>COMP<br>—<br>UL 489<br>J<br>30|—<br>RDF30J-4<br>UL 98<br>J<br>30|—<br>RDF60J-4-COMP<br>UL 98<br>J<br>60|—<br>RDF60J-4<br>UL 98<br>J<br>60|—<br>RDF100J-4<br>UL 98<br>J<br>100|—<br>RDF200J-4<br>UL 98<br>J<br>200|—<br>RDF400J-4<br>UL 98<br>J<br>400|—<br>RDF600J-4<br>UL 98<br>J<br>600|—<br>RDF800L-4<br>UL 98<br>L<br>800|Disconnect|switches|
|Switch type||Compact|Compact|Standard|Compact|Standard|Standard|Standard|Standard|Standard|Standard|||
|Handle operation||Front|Front|Front/Side|Front/Side|Front/Side|Front/Side ,<br>Flange|Front/Side ,<br>Flange|Front/Side ,<br>Flange|Front , Flange|Front , Flange|||
|UL electrical ratings||||||||||||||
|Max AC volts||600 Vac|600 Vac|600 Vac|600 Vac|600 Vac|600 Vac|600 Vac|600 Vac|600 Vac|600 Vac|||
|Max DC volts*||—|—|250 Vdc|250 Vdc|250 Vdc|250 Vdc|—|250 Vdc|600 Vdc|600 Vdc|||
||1-phase, 240|—|—|3|10|10|10|10|10|—|—|||
|Std. AC Hp<br>ratings|3-phase, 240<br>3-phase, 480|3<br>5.0|3<br>5.0|3<br>5.0|7.5<br>15|7.5<br>15|15<br>25|25<br>50|50<br>100|75<br>150|75<br>200|||
||3-phase, 600|7.5|7.5|7.5|15|15|30|60|125|200|250|||
|Max. AC Hp<br>ratings|3-phase, 240<br>3-phase, 480<br>3-phase, 600|7.5<br>15<br>20|7.5<br>15<br>20|7.5<br>15<br>20|15<br>30<br>50|15<br>30<br>50|30<br>60<br>75|60<br>125<br>150|125<br>250<br>350|200<br>400<br>500|200<br>500<br>500|||
|DC Hp ratings|125 Vdc<br>250 Vdc|—<br>—|—<br>—|3<br>5|5<br>10|5<br>10|7.5<br>20|—<br>—|20<br>50|—<br>—|—<br>—|||
|Electrical characteristics||||||||||||||
|SCCR||100 kA|100 kA|200 kA|100 kA|200 kA|200 kA|200 kA|200 kA|200 kA|200 kA|||
|Terminal lugs/kits||Integral|Integral|Integral|Integral|Integral|Integral|•|•|•|•|||
|Mounting torque-lb-in (N•m)||—|—|—|—|—|—|160 (18)|310 (35)|310 (35)|310 (35)|||
|Wire type||75°C Cu|75°C Cu|75°C Cu|75°C Cu|75°C Cu|75°C Cu|75°C Cu/ Al|75°C Cu/ Al|75°C Cu/ Al|75°C Cu/ Al|||
|Wire range,<br>torque - lb-in<br>(N•m)|Solid<br>Stranded|14-10,27<br>(3.1)<br>14-1027<br>(3.1)|14-10,27<br>(3.1)<br>14-1027 (3.1)|14-10,31<br>(3.5)<br>14-6 , 31<br>(3.5)|14-10,31 (3.5)<br>14-6,31 (3.5)|12-10,35.4<br>(4)<br>12-1,35.4<br>(4)|12-10,35.4<br>(4)<br>12-1,35.4 (4)|—<br>6-300 kcmil,<br>275 (31)|—<br>4-600 kcmil,<br>550 (62),<br>Dual 1/0-250<br>kcmil 550 (62)|—<br>(2) 2-600<br>kcmil,375<br>(42.4)|—<br>(2) 2-600<br>kcmil,375<br>(42.4)|||
|Mechanical characteristics||||||||||||||
|Endurances/cycles<br>Physical characteristics<br>Dimensions<br>2-pole||10,000<br>—|10,000<br>—|10,000<br>3.0 (1.3)|10,000<br>See drawings on product pages<br>3.1 (1.4)|10,000<br>10,000<br>8000<br>See drawings on product pages<br>4.1 (1.8)<br>4.1 (1.8)<br>5.7 (2.6)|||6000<br>11.4 (5.2)|5000<br>31.7 (14.4)|5000<br>31.7 (14.4)|||
|Weight - lbs<br>(kg)|3-pole<br>3-pole +<br>neutral|1.3 (0.6)<br>1.4 (0.6)|1.4 (0.6)<br>1.5 (0.7)|3.8 (1.7)<br>—|4.1 (1.8)<br>—|5.3 (2.4)<br>—|5.3 (2.4)<br>—|7.8 (3.5)<br>—|16.6 (7.6)<br>—|44.2 (20.1)<br>—|44.2 (20.1)<br>—|||
||4-pole|—|—|4.7 (2.1)|4.8 (2.2)|6.49 (2.9)|6.49 (2.9)|10.8 (4.9)|21.8 (9.9)|56.8 (25.8)|56.8 (25.8)|||
|Environmental||||||||||||||
|Operating temp. range<br>Flammability rating<br>Accessories||-20-70°C<br>UL 94-V0|-20-70°C<br>UL 94-V0|-20-70°C<br>UL 94-V0|-20-70°C<br>UL 94-V0|-20-70°C<br>UL 94-V0|-20-70°C<br>UL 94-V0|-20-70°C<br>UL 94-V0|-20-70°C<br>UL 94-V0|-20-70°C<br>UL 94-V0|-20-70°C<br>UL 94-V0|||
|Lug Kit||Integral|Integral|Integral|Integral|Integral|Integral|•|•|•|•|||
||Direct|•|•|•|•|•|•|•|•|•|•|||
||Front|||||||||||||
|Handles|selector|•|•|—|—|—|—|—|—|—|—|||
||Front pistol|•|•|•|•|•|•|•|•|•|•|||
||Side pistol|—|—|•|•|•|•|•|•|—|—|||
|Flange|Cable<br>Shaft|—<br>—|—<br>—|•<br>•|•<br>•|•<br>•|•<br>•|•<br>•|—<br>—|—<br>—|—<br>—|||
|NFPA through door handle||•|•|•|•|•|•|•|•|•|•|||
|Shafts c/s-mm||5x5|5x5|10x10|10x10|10x10|10x10|10x10|10x10|12X12|12X12|||
|Terminal shrouds||Not<br>Required|Not<br>Required|Not<br>Required|Not Required|Not<br>Required|Not<br>Required|•|•|•|•|||
|Auxiliary|(1) NO|•|•|•|•|•|•|•|•|•|•|||
|contacts|(1) NC|•|•|•|•|•|•|•|•|•|•|||
|AC ratings|Volts<br>Amps|600<br>10|600<br>10|600<br>10|600<br>10|600<br>10|600<br>10|600<br>10|600<br>10|600<br>10|600<br>10|||
- Available, see product page for details and catalog numbers.
- Not available.
- General purpose only, not photovoltaic rated.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-55
**11 — Disconnect switches** ata
## UL 98 fused rotary disconnect switches — 30 A
Standard 30 amp Class CC and compact 30 amp Class J For a complete assembly, select:
|||Switch|||
|---|---|---|---|---|
|||Fuse<br>SCCR<br>Max Hpratin|rating,3-phase<br>Conductor||
|||Amps<br>class<br>Poles<br>(kA)<br>220/240|AWG size/type<br>440/480<br>600|Catalogno.|
||Switch|30<br>CC<br>3<br>100<br>7.5<br>30<br>3 + Ntrl.*<br>100<br>7.5<br>30<br>J<br>3<br>100<br>7.5<br>30<br>3 + Ntrl.*<br>100<br>7.5|15<br>20<br>14-10 Sol/Str<br>75°C Cu<br>15<br>20<br>15<br>20<br>15<br>20|RDF30CC-3<br>RDF30CC-3N<br>RDF30J-3-COMP<br>RDF30J-3N-COMP|
|||* Neutral is switched.|||
||||Plus||
|||Direct mount handle - mounts directlyto switch,no shaft required|||
|||For switch cat. no.<br>Color<br>Test function|Padlockable|Catalogno.|
|||RDF30CC-_||DIR-05|
|||Black<br>Y<br>RDF30J-_-COMP|Y|DIR-06|
|Select for standard applications|Handle<br>OR<br>+<br>External front operated selector handle - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,4,4X,12<br>Black<br>N<br>Y<br>Y<br>H4X-04B<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-04R<br>Shafts for selector handles<br>Length - in(mm)<br>Mountingdepth(X)- in(mm)<br>Catalogno.<br>7.9(200)<br>4.02~9.65(102~245)<br>SH1-200<br>12.6(320)<br>4.02~14.37(102~365)<br>SH1-320<br>15.7(400)<br>4.02~17.52(102~445)<br>SH1-400<br>OR<br>External front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,12<br>Black<br>N<br>Y<br>Y<br>H12-05B<br>1,3R,12<br>Red/yellow<br>H12-05R<br>1,3R,4,4X,12<br>Black<br>H4X-05B<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-05R<br>1,3R,4,4X,12<br>Black<br>Y<br>H4X-05TB<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-05TR<br>or<br>Metallic hasp (heavyduty)external front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 4, 4X, 12<br>Black<br>N<br>Y<br>Y<br>H4X-05BHD<br>1, 3R, 4, 4X, 12<br>Red/yellow<br>H4X-05RHD<br>+<br>Shafts forpistol handles<br>Length - in(mm)<br>Mountingdepth(X)- in(mm)<br>Catalogno.<br>7.9(200)<br>4.02~9.65(102~245)<br>SH2-200<br>12.6(320)<br>4.02~14.37(102~365)<br>SH2-320<br>15.7(400)<br>4.02~17.52(102~445)<br>SH2-400<br>~~CO~~<br>~~————————~~<br>~~l=~~<br>~~———~~<br>~~—~~<br>~~=~~<br>~~——~~<br>~~—~~<br>~~ses~~||||
||||OR||
|||NFPA through the door handle kit - to be used with frontpistol handle|||
|||Color<br>Test function|Padlockable<br>Defeatable|Catalogno.|
|||Red<br>N<br>Ss|Y<br>N|H79-1|
||||AND...||
|||Auxiliarycontacts|||
|Accessories|Auxiliary contacts|1 2<br>Contact<br>type<br>No. of<br>contacts<br>Continuous<br>amprating<br>Voltage(Vac)<br>NO<br>1<br>10<br>600<br>NC<br>Auxiliary contact holder<br>_|Maximum number of auxiliary contacts per<br>disconnect switch catalognumber<br>RDF30CC-_: 4 / 8 with BAC-HOLDER2<br>BAC05 (1) RDF30J-_-COMP: 2 /6 with BAC-<br>HOLDER2<br>Accepts 4 Auxiliary contacts: BAC05 or<br>BAC06|Catalogno.<br>BAC05(1)<br>BAC06 (1)<br>BAC-HOLDER2 (2)|
Eaton.com/bussmannseries
11-56
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
Dimensions — in (mm)
RDF30CC-_
**==> picture [122 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.28<br>83.3 1.12<br>28.5<br>5.19 (131.8)<br>Fuse Cover Fully Open<br>**----- End of picture text -----**<br>
**==> picture [200 x 431] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.78<br>96 1.47 0.59<br>37.5 15<br>4.13<br>105<br>1.47 0.59<br>37.5 15<br>Door drilling layout<br>1.57<br>40<br>0.11<br>4 Ø 0.27 3<br>4 Ø 7<br>Ø 1.22Ø 31<br>Ø 31 With 4 Mounting Screws Ø Ø 22.50.88Ø 22.50.8822.50.880.88 With mounting nut<br>1<br>25.5<br>4.56 116<br>3.3 84<br>1<br>25.5<br>4.56 116<br>3.3 84<br>0.53 13.5<br>1.10 28<br>**----- End of picture text -----**<br>
RDF30J-_-COMP
**==> picture [89 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.89<br>99<br>1.12<br>28.5<br>**----- End of picture text -----**<br>
**==> picture [162 x 97] intentionally omitted <==**
## External front selector handle
**==> picture [398 x 286] intentionally omitted <==**
**----- Start of picture text -----**<br>
Selector handle type Direction of front operation Door drilling layout<br>1.57<br>I 40<br>0.11<br>Ø3.07 4 Ø 0.27 3<br>Ø78 4 Ø 7<br>0<br>H4X-04_ 1.4537 Ø 1.22Ø 31 With 4 Mounting Screws Ø Ø 22.50.88Ø 22.50.8822.50.880.88 With mounting nut<br>Pistol handle type Direction of front operation Door drilling layout<br>I<br>Ø 1.46<br>Ø3.07 4 Ø 0.27 Ø 37<br>Ø78 4 Ø 7<br>0<br>H4X-05__<br>1.73<br>H12-05__ 44<br>TEST 0.55 0.55<br>14 14<br>90°<br>90°<br>3.46 88 1.10 28 0.53 13.5<br>0.78 20<br>2.75 70<br>65° 0.78 20<br>**----- End of picture text -----**<br>
External front pistol handles
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-57
**11 — Disconnect switches** ~~I~~ FC ce Standard 30 amp Class J
For a complete assembly, select:
||Switch|
|---|---|
||Max horsepower rating|
||Fuse<br>SCCR<br>Conductors<br>1-phase<br>3-phase<br>DC*|
||Switch<br>Amps<br>class<br>Poles<br>(kA)<br>AWG size / type<br>Catalogno.<br>220/240<br>220/240<br>440/480<br>600<br>125<br>250<br>30<br>J<br>2<br>200<br>3<br>-<br>-<br>-<br>3<br>5<br>14-10 Sol/14-6 Str<br>75°C Cu<br>RDF30J-2<br>3<br>-<br>7.5<br>15<br>20<br>3<br>5<br>RDF30J-3<br>4<br>-<br>7.5<br>15<br>20<br>3<br>5<br>RDF30J-4|
||* DC ratings use twopoles in series.|
||PLUS|
|Select for standard applications|Handle<br>Direct mount handle - mounts directlyto switch,no shaft required<br>For switch cat. no.<br>Color<br>Test function<br>Padlockable<br>Catalogno.<br>All switches<br>Black<br>Y<br>Y - On switch<br>DIR-07<br>OR<br>Or<br>External front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 12<br>Black<br>N<br>Y<br>Y<br>H12-05B<br>Red/yellow<br>H12-05R<br>1, 3R, 4, 4X, 12<br>Black<br>H4X-05B<br>Red/yellow<br>H4X-05R<br>Black<br>Y<br>H4X-05TB<br>Red/yellow<br>H4X-05TR<br>Metallic hasp (heavyduty)external front operatedpistol handles - shaft required<br>NEMA<br>type<br>Color<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalog no.<br>1, 3R, 4, 4X, 12<br>Black<br>N<br>Y<br>Y<br>H4X-05BHD<br>Red/yellow<br>H4X-05RHD<br>External right side operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 4, 4X, 12<br>Black<br>N<br>Y<br>N/A<br>H4X-05SB<br>Red/yellow<br>H4X-05SR<br>+<br>Shafts forpistol handles<br>Length — in(mm)<br>Mountingdepth(X)— in(mm)<br>Catalogno.<br>7.9(200)<br>5.30~9.06(135~230)<br>SH5-200<br>12.6(320)<br>5.30~13.78(135~350)<br>SH5-320<br>15.7(400)<br>5.30~16.93(135~430)<br>SH5-400<br>OR<br>Flange handle(1)- requires shaft operated mechanism or cable operated mechanism + cable<br>NEMA type<br>Flange style<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,4,12<br>Standard<br>N<br>Y<br>Y<br>FLH1<br>1,3R,4,4X,12<br>Chromeplated<br>FLH2<br>Shaft operated flange mechanism(2)- includes shaft<br>For enclosure depth - in(mm)<br>Catalogno.<br>6~24(152~613)<br>FLRM<br>Cable operated flange mechanism and cable - must select mechanism(3)and cable(4)<br>Item / length — in(mm)<br>Catalogno.<br>Cable mechanism<br>FLCM<br>36(900)cable<br>FLC36<br>60(1500)cable<br>FLC60<br>120(3000)cable<br>FLC120<br>OR<br>NFPA through the door handle kit - to be used with frontpistol handle<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>Red<br>N<br>Y<br>N<br>H79-2<br>1<br>4<br>3<br>2<br>~~eerr~~<br>?<br>~~=~~<br>~~ee~~<br>) ~~—....z,~~<br>~~a~~<br>~~SESE~~<br>~~—_=~~<br>~~————————————————~~<br>~~——~~|
|AND...<br>Accessories<br>Aux. contacts<br>Auxiliarycontacts<br>Contact<br>type<br>No. of contacts<br>Continuous amp rating<br>Voltage (Vac)<br>Max. aux contacts per switch<br>Catalog no.<br>NO<br>1<br>10<br>600<br>4<br>BAC05<br>NC<br>BAC06<br>~~tc—~~||
Eaton.com/bussmannseries
11-58 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## Dimensions — in (mm)
**==> picture [364 x 527] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.87<br>149.3 4.84<br>123<br>1.41<br>1.46 1.41<br>36<br>37.2 36<br>Direct mount handle<br>1.57 1.79<br>40 45.5<br>DIR-07<br>Flange handle<br>3.50<br>(88.9) Ø0.28<br>2.16 (Ø7.1)<br>(54.9)<br>Ø0.50 1.55<br>0.86 1.06 (Ø12.7) (39.4)<br>(26.9)<br>(21.8)<br>4.68<br>5.66 1.00 (118.9)<br>6.22 (143.8) (25.4)<br>(158.0)<br>1.00 0.88<br>(25.4) (22.3)<br>2.32<br>(58.9) 2.70<br>7.10<br>(68.6)<br>(180.3)<br>2.68 68.07<br>5.35 136 4.02 102.1<br>5.31 135<br>**----- End of picture text -----**<br>
FLH_
External front and right side pistol handle
**==> picture [391 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
Handle type Direction of front operation Direction of right side operation Door drilling layout<br>I<br>I<br>Ø 1.46<br>Ø3.07 4 Ø 0.27 Ø 37<br>Ø78 4 Ø 7<br>0 0<br>H4X-05__ 1.73<br>H12-05__ 44<br>TEST 0.55 0.55<br>14 14<br>90°<br>90°<br>0.78 20<br>2.75 70<br>65° 0.78 20<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-59
**11 — Disconnect switches** FC)
## Compact 60 amp Class J
For a complete assembly, select:
||Switch||
|---|---|---|
||Max horsepower rating||
||Fuse<br>SCCR<br>1-phase<br>3-phase<br>DC*<br>Conductor||
||Switch<br>Amps<br>class<br>Poles<br>(kA)<br>Catalogno.<br>AWG size / type<br>220/240<br>220/240<br>440/480<br>600<br>125<br>250<br>60<br>J<br>2<br>100<br>10<br>-<br>-<br>-<br>5<br>10<br>14-10 Sol/14-6 Str<br>75°C Cu<br>RDF60J-2-COMP<br>3<br>-<br>15<br>30<br>50<br>5<br>10<br>RDF60J-3-COMP<br>4<br>-<br>15<br>30<br>50<br>5<br>10<br>RDF60J-4-COMP<br>~~aaa~~||
||* DC ratings use twopoles in series.||
||PLUS||
||Direct mount handle - mounts directlyto switch,no shaft required<br>For switch cat. no.<br>Color<br>Test function<br>Padlockable<br>Catalogno.<br>All switches<br>Black<br>Y<br>Y - on switch<br>DIR-07<br>OR<br>~~rr~~||
||External front operatedpistol handles - shaft required||
|Select for standard applications<br>Handle<br>Or<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,12<br>Black<br>N<br>Y<br>Y<br>H12-05B<br>1,3R,12<br>Red/yellow<br>H12-05R<br>1,3R,4,4X,12<br>Black<br>H4X-05B<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-05R<br>1,3R,4,4X,12<br>Black<br>Y<br>H4X-05TB<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-05TR<br>Metallic hasp (heavyduty)external front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,4,4X,12<br>Black<br>N<br>Y<br>Y<br>H4X-05BHD<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-05RHD<br>External right side operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,4,4X,12<br>Black<br>N<br>Y<br>N/A<br>H4X-05SB<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-05SR<br>+<br>Shafts forpistol handles<br>Length — in(mm)<br>Mountingdepth(X)- in(mm)<br>Catalogno.<br>7.9(200)<br>5.30~9.06(135~230)<br>SH5-200<br>12.6(320)<br>5.30~13.78(135~350)<br>SH5-320<br>15.7(400)<br>5.30~16.93(135~430)<br>SH5-400<br>OR<br>Flange handle(1)- requires shaft operated mechanism or cable operated mechanism + cable<br>NEMA type<br>Flange style<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,4,12<br>Standard<br>N<br>Y<br>Y<br>FLH1<br>1,3R,4,4X,12<br>Chromeplated<br>FLH2<br>Shaft operated flange mechanism(2)- includes shaft<br>For enclosure depth - in(mm)<br>Catalogno.<br>6~24(152~613)<br>FLRM<br>Cable operated flange mechanism and cable - must select mechanism(3)and cable(4)<br>Item / length — in(mm)<br>Catalogno.<br>Cable mechanism<br>FLCM<br>36(900)cable<br>FLC36<br>60(1500)cable<br>FLC60<br>120(3000)cable<br>FLC120<br>OR<br>NFPA through the door handle kit - to be used with selector handle or frontpistol handle<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>Red<br>N<br>Y<br>N<br>H79-2<br>AND...<br>Accessories<br>Aux. contacts<br>Auxiliarycontacts<br>Contact type<br>No. of contacts<br>Continuous amp<br>rating<br>Voltage (Vac)<br>Max. aux contacts per switch<br>Catalog no.<br>NO<br>1<br>10<br>600<br>4<br>BAC05<br>NC<br>BAC06<br>1<br>4<br>3<br>2<br>~~ne~~<br>~~—~~<br>— ~~— —_—_==~~<br>~~=~~<br>—~~——_{£_—_=~~<br>~~rl~~<br>~~————————~~<br>So.~~a~~<br>~~—~~<br>'s~~re~~<br>~~OOlrT—~~<br>~~it~~|||
Eaton.com/bussmannseries
11-60
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## Dimensions — in (mm)
**==> picture [112 x 41] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.89<br>99<br>1.12<br>28.5<br>**----- End of picture text -----**<br>
**==> picture [204 x 123] intentionally omitted <==**
**==> picture [190 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.13<br>105<br>1.47 0.59<br>37.5 15<br>1<br>25.5<br>4.56 116<br>3.3 84<br>**----- End of picture text -----**<br>
## Direct mount handle
**==> picture [285 x 274] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.57 1.79<br>40 45.5<br>DIR-07<br>Flange handle<br>3.50<br>(88.9) Ø0.28<br>2.16 (Ø7.1)<br>(54.9)<br>Ø0.50 1.55<br>0.86 1.06 (Ø12.7) (39.4)<br>(26.9)<br>(21.8)<br>4.68<br>5.66 1.00 (118.9)<br>6.22 (143.8) (25.4)<br>(158.0)<br>1.00 0.88<br>(25.4) (22.3)<br>2.32<br>(58.9) 2.70<br>7.10<br>(68.6)<br>(180.3)<br>5.31 135<br>**----- End of picture text -----**<br>
FLH_
External front and right side pistol handle
Handle type Direction of front operation Direction of right side operation Door drilling layout
**==> picture [495 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
I<br>I<br>Ø 1.46<br>Ø3.07 4 Ø 0.27 Ø 37<br>Ø78 4 Ø 7<br>0<br>0<br>H4X-05__ 1.73<br>H12-05__ 44<br>TEST 0.55 0.55<br>14 14<br>90°<br>90°<br>0.78 20<br>2.75 70<br>0.78 20<br>65°<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-61
**11 — Disconnect switches** TON
Standard 60 amp Class J
For a complete assembly, select:
||Switch||
|---|---|---|
||Max horsepower rating||
||Fuse<br>SCCR<br>Conductor AWG<br>1-phase<br>3-phase<br>DC*||
||Switch<br>Amps<br>class<br>Poles<br>(kA)<br>size/type<br>Catalogno.<br>220/240<br>220/240<br>440/480<br>600<br>125<br>250<br>60<br>J<br>2<br>200<br>10<br>-<br>-<br>-<br>5<br>10<br>12-10 Sol/12-1 Str<br>75°C Cu<br>RDF60J-2<br>3<br>200<br>-<br>15<br>30<br>50<br>5<br>10<br>RDF60J-3<br>4<br>200<br>-<br>15<br>30<br>50<br>5<br>10<br>RDF60J-4<br>* DC ratings use twopoles in series.<br>~~ee~~||
||PLUS||
||Direct mount handle - mounts directlyto switch,no shaft required||
||For switch cat. no.<br>Color<br>Test function<br>Padlockable|Catalogno.|
|Select for standard applications|Handle<br>All switches<br>Black<br>Y<br>Y<br>DIR-07<br>OR<br>External front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,12<br>Black<br>N<br>Y<br>Y<br>H12-03B<br>1,3R,12<br>Red/yellow<br>H12-03R<br>1,3R,4,4X,12<br>Black<br>H4X-06B<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-06R<br>1,3R,4,4X,12<br>Black<br>Y<br>H4X-06TB<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-06TR<br>Or<br>Metallic hasp (heavyduty)external front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,4,4X,12<br>Black<br>N<br>Y<br>Y<br>H4X-06BHD<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-06RHD<br>External right side operated pistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,4,4X,12<br>Black<br>N<br>Y<br>N/A<br>H4X-06SB<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-06SR<br>+<br>Shafts forpistol handles<br>Length — in(mm)<br>Mountingdepth(X)— in(mm)<br>Catalogno.<br>7.9(200)<br>5.30~9.06(135~230)<br>SH5-200<br>12.6(320)<br>5.30~13.78(135~350)<br>SH5-320<br>15.7(400)<br>5.30~16.93(135~430)<br>SH5-400<br>OR<br>Flange handle(1)- requires shaft operated mechanism or cable operated mechanism + cable<br>NEMA type<br>Flange style<br>Test Function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,4,12<br>Standard<br>N<br>Y<br>Y<br>FLH1<br>1,3R,4,4X,12<br>Chromeplated<br>FLH2<br>Shaft operated flange mechanism(2)- includes shaft<br>For enclosure depth — in(mm)<br>Catalogno.<br>6~24(152~613)<br>FLRM<br>Cable operated flange mechanism and cable - must select mechanism(3)and cable(4)<br>Item / length — in(mm)<br>Catalogno.<br>Cable mechanism<br>FLCM<br>36(900)cable<br>FLC36<br>60(1500)cable<br>FLC60<br>120(3000)cable<br>FLC120<br>OR<br>NFPA through the door handle kit - to be used with frontpistol handle<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>Red<br>N<br>Y<br>N<br>H79-2<br>AND...<br>1<br>4<br>3<br>2<br>~~SS~~<br>~~——~~<br>? ~~———————~~<br>~~————~~<br>~~——_—_—_E~~<br>~~SS~~<br>~~———~~<br>~~CSE=~~<br>~~——————————~~<br>~~SSL —_——~~<br>~~SSTT~~||
|Accessories|Aux. contacts<br>Auxiliarycontacts<br>Contact type<br>No. of contacts<br>Continuous amp<br>rating<br>Voltage (Vac)<br>Max number of aux contacts per<br>switch<br>NO<br>1<br>10<br>600<br>4<br>NC|Catalog no.<br>BAC05<br>BAC06|
Eaton.com/bussmannseries
11-62
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## Dimensions — in (mm)
**==> picture [351 x 489] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.87 4.81<br>149.3 1.41 122.2<br>1.41 1.46 36<br>36 37.2<br>Direct mount handle<br>1.57 1.79<br>40 45.5<br>DIR-07<br>Flange handle<br>3.50<br>(88.9) Ø0.28<br>2.16 (Ø7.1)<br>(54.9)<br>Ø0.50 1.55<br>0.86 1.06 (Ø12.7) (39.4)<br>(26.9)<br>(21.8)<br>4.68<br>5.66 1.00 (118.9)<br>6.22 (143.8) (25.4)<br>(158.0)<br>1.00 0.88<br>(25.4) (22.3)<br>2.32<br>(58.9) 2.70<br>7.10<br>(68.6)<br>(180.3)<br>FLH_<br>3.66 92.96<br>7.32 186 6.77 172 5.23 133<br>5.31 135<br>**----- End of picture text -----**<br>
External front and right side pistol handle
Handle type Direction of front operation Direction of right side operation Door drilling layout
**==> picture [487 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
I<br>I<br>Ø3.07<br>Ø 1.46<br>Ø78<br>4 Ø 0.27 Ø 37<br>4 Ø 7<br>0<br>H4X-06__<br>1.77<br>H12-03__ 45 TEST 0.55 0.55<br>14 14<br>90°<br>90°<br>0.78 20<br>4.92 125 0<br>65° 0.78 20<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-63
**11 — Disconnect switches** ~~7~~
Standard 100 amp Class J
For a complete assembly, select:
||Switch|
|---|---|
||Max horsepower rating|
||Fuse<br>SCCR<br>Conductor<br>1-phase<br>3-phase<br>DC*|
||Switch<br>Amps<br>class<br>Poles<br>(kA)<br>AWG size/type<br>Catalogno.<br>220/240<br>220/240<br>440/480<br>600<br>125<br>250<br>100<br>J<br>2<br>200<br>10<br>-<br>-<br>-<br>7.5<br>20<br>12-10 Sol/12-1 Str<br>75°C Cu<br>RDF100J-2<br>3<br>-<br>30<br>60<br>75<br>7.5<br>20<br>RDF100J-3<br>4<br>-<br>30<br>60<br>75<br>7.5<br>20<br>RDF100J-4<br>* DC ratings use twopoles in series.<br>~~——————~~|
||PLUS|
|Select for standard applications|Handles<br>Direct mount handle - mounts directlyto switch,no shaft required<br>For switch cat.<br>no.<br>Color<br>Test function<br>Padlockable<br>Catalog no.<br>All switches<br>Black<br>Y<br>Y<br>DIR-07<br>OR<br>External front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 12<br>Black<br>N<br>Y<br>Y<br>H12-03B<br>Red/yellow<br>H12-03R<br>1, 3R, 4, 4X, 12<br>Black<br>H4X-06B<br>Red/yellow<br>H4X-06R<br>Black<br>Y<br>H4X-06TB<br>Red/yellow<br>H4X-06TR<br>Or<br>Metallic hasp(heavyduty) external front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,4,4X,12<br>Black<br>N<br>Y<br>Y<br>H4X-06BHD<br>1,3R,4,4X,12<br>Red/yellow<br>H4X-06RHD<br>External right side operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 4, 4X, 12<br>Black<br>N<br>Y<br>N/A<br>H4X-06SB<br>Red/yellow<br>H4X-06SR<br>+<br>Shafts forpistol handles<br>Length — in<br>(mm)<br>Mounting depth (X) - in (mm)<br>Catalog no.<br>7.9(200)<br>5.30~9.06(135~230)<br>SH5-200<br>12.6(320)<br>5.30~13.78(135~350)<br>SH5-320<br>15.7(400)<br>5.30~16.93(135~430)<br>SH5-400<br>~~—————~~<br>_~~—————s~~<br>~~=~~<br>? ~~88S~~<br>~~—~~<br>~~—~~|
||OR<br>Flange handle(1)- requires shaft operated mechanism or cable operated mechanism + cable<br>NEMA type<br>Flange style<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,4,12<br>Standard<br>N<br>Y<br>Y<br>FLH1<br>1,3R,4,4X,12<br>Chromeplated<br>FLH2<br>Shaft operated flange mechanism(2)- includes shaft<br>For enclosure depth — in(mm)<br>Catalogno.<br>6~24(152~613)<br>FLRM<br>Cable operated flange mechanism and cable - must select mechanism(3)and cable(4)<br>Item / length — in(mm)<br>Catalogno.<br>Cable mechanism<br>FLCM<br>36(900)cable<br>FLC36<br>60(1500)cable<br>FLC60<br>120(3000)cable<br>FLC120<br>OR<br>NFPA through the door handle kit - to be used with frontpistol handle<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>Red<br>N<br>Y<br>N<br>H79-2<br>1<br>4<br>3<br>2<br>~~KKSe~~<br>é:~~a~~<br>~~ooo~~<br>~~7~~<br>~~eEEE——EE=E==~~|
|AND...<br>Accessories<br>Aux. contacts<br>Auxiliarycontacts<br>Contact type<br>No. of contacts<br>Continuous amp<br>rating<br>Voltage (Vac)<br>Max number of aux contacts<br>per switch<br>Catalog no.<br>NO<br>1<br>10<br>600<br>4<br>BAC05<br>NC<br>BAC06<br>~~(ee—~~||
Eaton.com/bussmannseries
11-64
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
Dimensions — in (mm)
**==> picture [345 x 468] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.87 4.81<br>149.3 1.41 122.2<br>1.41 1.46 36<br>36 37.2<br>Direct mount handle<br>1.57 1.79<br>40 45.5<br>DIR-07<br>Flange handle<br>3.50<br>(88.9) Ø0.28<br>2.16 (Ø7.1)<br>(54.9)<br>Ø0.50 1.55<br>0.86 1.06 (Ø12.7) (39.4)<br>(26.9)<br>(21.8)<br>4.68<br>5.66 1.00 (118.9)<br>6.22 (143.8) (25.4)<br>(158.0)<br>1.00 0.88<br>(25.4) (22.3)<br>2.32<br>(58.9) 2.70<br>7.10<br>(68.6)<br>(180.3)<br>3.66 92.96<br>7.32 186 6.77 172 5.23 133<br>5.31 135<br>**----- End of picture text -----**<br>
FLH_
External front and right side pistol handle
Handle type Direction of front operation Direction of right side operation Door drilling layout
**==> picture [487 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
I<br>I<br>Ø3.07<br>Ø 1.46<br>Ø78<br>4 Ø 0.27 Ø 37<br>4 Ø 7<br>0<br>H4X-06__<br>1.77<br>H12-03__ 45 TEST 0.55 0.55<br>14 14<br>90°<br>90°<br>0.78 20<br>4.92 125 0<br>65° 0.78 20<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-65
**11 — Disconnect switches** ~~<0~~
Standard 200 and 400 amp Class J
For a complete assembly, select:
|||Switch|||
|---|---|---|---|---|
|||Max horsepower rating|||
|||Fuse<br>SCCR<br>1-phase<br>3-phase<br>DC*|||
|||Amps<br>class<br>Poles<br>(kA)<br>220/240<br>220/240<br>440/480<br>600<br>125<br>250||Catalogno.|
|||2<br>10<br>-<br>-<br>-<br>-<br>-||RDF200J-2|
||Switch + lugs|200<br>J<br>200<br>3<br>-<br>60<br>125<br>150<br>-<br>-<br>RDF200J-3<br>4<br>-<br>60<br>125<br>150<br>-<br>-<br>RDF200J-4<br>400<br>2<br>10<br>-<br>-<br>-<br>20<br>50<br>RDF400J-2<br>3<br>-<br>125<br>250<br>350<br>20<br>50<br>RDF400J-3<br>4<br>-<br>125<br>250<br>350<br>20<br>50<br>RDF400J-4<br>* DC ratings use twopoles in series.<br>+<br>Terminal lugkit<br>Switch amps<br>Poles<br>Lugsper kit<br>AWG wire / type<br>Catalogno.<br>~~——=—_—_—=~~|||
|||200<br>2<br>2<br>6-300 kcmil<br>75°C Cu/Al<br>3<br>3<br>4<br>4||LUG1-2<br>LUG1-3<br>LUG1-4|
|||400<br>2<br>2<br>4-600 kcmil or dual 1/0-250 kcmil<br>75°C Cu/Al<br>3<br>3<br>4<br>4||LUG2-2<br>LUG2-3<br>LUG2-4|
|||PLUS|||
|||Direct mount handle - mounts directlyto switch,no shaft required|||
|||For switch cat. no.<br>Color<br>Test function<br>Padlockable||Catalogno.|
|||All switches<br>Black<br>Y<br>Y||DIR-07|
|Select for standard applications|Handles<br>OR<br>External front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 12<br>Black<br>N<br>Y<br>Y<br>H12-03B<br>Red/yellow<br>H12-03R<br>1, 3R, 4, 4X, 12<br>Black<br>H4X-06B<br>Red/yellow<br>H4X-06R<br>Black<br>Y<br>H4X-06TB<br>Red/yellow<br>H4X-06TR<br>Or<br>Metallic hasp (heavyduty)external front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 4, 4X, 12<br>Black<br>N<br>Y<br>Y<br>H4X-06BHD<br>Red/yellow<br>H4X-06RHD<br>External right side operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 4, 4X, 12<br>Black<br>N<br>Y<br>N/A<br>H4X-06SB<br>Red/yellow<br>H4X-06SR<br>+<br>Shafts forpistol handles<br>Length — in(mm)<br>Mountingdepth(X)— in(mm)<br>Catalogno.<br>~~rrr~~<br>~~=<~~<br>~~=~~<br>~~————~~||||
|||7.9 (200)<br>200 A: 5.70-9.06(145-230)<br>400 A: 7.87-10.24(200-260)<br>12.6 (320)<br>200 A: 5.70-13.78(145-350)<br>400 A: 7.87-16.93 (200-380)<br>15.7 (400)<br>200 A: 5.70-16.93(145-430)<br>400 A: 7.87-18.10(200-460)<br>~~7~~||SH5-200<br>SH5-320<br>SH5-400|
||OR<br>Flange handle (1) 200 A only - requires shaft operated mechanism or cable operated mechanism +<br>cable<br>NEMA type<br>Flange style<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1,3R,4,12<br>Standard<br>N<br>Y<br>Y<br>FLH1<br>1,3R,4,4X,12<br>Chromeplated<br>FLH2<br>Shaft operated flange mechanism(2)200 A only- includes shaft<br>For enclosure depth — in(mm)<br>Catalogno.<br>6~24(152~613)<br>FLRM<br>Cable operated flange mechanism and cable 200 A only- must select Mechanism (3) and Cable (4)<br>Item — in(mm)<br>Catalogno.<br>Cable mechanism<br>FLCM<br>36(900)cable<br>FLC36<br>60(1500)cable<br>FLC60<br>120(3000)cable<br>FLC120<br>1<br>4<br>3<br>2<br>~~a~~<br>i.~~—_~~<br>~~——~~||||
Eaton.com/bussmannseries
11-66
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
## **Disconnect switches — 11**
||||||||||||||||OR|||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||||NFPA through the door handle kit - to be used with front|h the door handle kit - to be used with frontpistol handle||||istol handle|||||||
|||||||||||||Use with switch||Color|Test function||Padlockable||Defeatable|Catalogno.||||
|||||||||||||RDF200J-_||||||||H79-2||||
|||||||||||||||Red|N|||Y|N|||||
|||||||||||||RDF400J-_||||||||H79-3||||
||||||||||||||||AND...|||||||||
|||||||||||||Auxiliarycontacts||||||||||||
||Aux. contacts|||||||||||Contact type<br>NO<br>NC<br>Terminal shrouds - includes terminal shroud for lineside or loadside|No. of contacts<br>Continuous amp<br>rating<br>Voltage (Vac)<br>1<br>10<br>600<br>AND...<br>Terminal shrouds - includes terminal shroud for lineside or loadside||||||Max number of<br>aux contacts per<br>switch catalog<br>number<br>RDF200J-__: 4<br>RDF400J-__: 8|Catalog no.<br>BAC05<br>BAC06||Disconnect|switches|
|Accessories||||||||||||Switch amps<br>200|Poles<br>2<br>3|||||||Catalogno.<br>TSH8-2TB<br>TSH8-3TB||||
||Shrouds|aos||VEGen|||ae <br>Tt||Ue <br>UN||||4<br>TSH8-4TB<br>2<br>TSH9-2TB<br>3<br>TSH9-3TB<br> ~~ee~~<br>~~©»~~<br>~~»»_~~||||||||||||
|||-|pte<br>,<br>+<br>||||||a||1s<br>a<br>a||a|400||||||||||||
||||||||||||||4|||||||TSH9-4TB||||
Dimensions — in (mm) RDF200J-3
RDF400J-3
**==> picture [506 x 207] intentionally omitted <==**
**----- Start of picture text -----**<br>
7.72<br>196.2<br>7.08<br>6.61 180<br>168 4.37 10.19 (3P) - 12.79 (4P)<br>6.18 111.1 259 (3P) - 325 (4P)<br>157<br>| 7 =<br>\ TES==| =o L| poll ianlienl lien<br>VQ dq[|] op — eh ails it.<br>©@© ©—— —OH= Cc geo998900000Qoo000 | || cooood boone000000 ||| 000000 coooo ooocc5bk Hel=hisene!oC | le iesH\ } abeqde aN© al=© H(]ptfoaoo0000gaoagece | sageneseOooooccsdooo0000cooo0000 | | || Soooo00n cooooocDcooooc00sooo0000 | soooo000[ty |||| saescecs coocoocGooooo000sooooooo fFTIPaWA<br>O 000000o0o00000 | | oooooo 000000 |}| oooooo oo0000 JOTan "JII~ o @ | fj Cocececs | seoccan | soooonen jos[eoa<br>O ot 000000SEEdooo00000000 | | oooo00| 000000HEEESEE | | oooooo} coo000 ||Y “| —ae;© 2q | l]l sooo0000 | oooo0000 | oooo0000 Oear_||L+~}<br>6? stellate900000 | 000000ately j oo0000 4 2 ° © ) ( | 00000000 |Eeseeee | Ooo000000 Sesesese | coooo000| aeaeaeae |||<br>: © ae: od= C{oo0000000000 ||| oo0000 000000 000000 ||| 900000 oo0000oo0000 = f rTeo. , eMOm @) JHi Oo000000 | cooooo00 | cooooo00 nhFP+<br>(( TS Ge ae GB <aLlJi |[] b wo I o o c | 0.9824.9<br>1.41<br>36 3.26<br>z= a H H = lLy LZ | CET 83<br>5.11 | 1.96 ee<br>130 50 2.59 2.59<br>66 66<br>2.95 75<br>3.98<br>101.25<br>5.28 134.2 6.50 165.2 7.67 195 11.46 291.3 7.97 202.5 15.35 390 9.44 240<br>3.98<br>101.25<br>2.95 75<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-67
**11 — Disconnect switches**
Dimensions — in (mm)
DIR-07 direct mount handle
## FLH_ flange handle
**==> picture [96 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.57 1.79<br>40 45.5<br>5.31 135<br>**----- End of picture text -----**<br>
**==> picture [286 x 144] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.50<br>(88.9) Ø0.28<br>2.16 (Ø7.1)<br>(54.9)<br>Ø0.50 1.55<br>0.86 1.06 (Ø12.7) (39.4)<br>(26.9)<br>(21.8)<br>4.68<br>5.66 1.00 (118.9)<br>6.22 (143.8) (25.4)<br>(158.0)<br>1.00 0.88<br>(25.4) (22.3)<br>2.32<br>(58.9) 2.70<br>7.10<br>(68.6)<br>(180.3)<br>**----- End of picture text -----**<br>
External front and right side pistol handle
**==> picture [491 x 352] intentionally omitted <==**
**----- Start of picture text -----**<br>
Handle type Direction of front operation Direction of right side operation Door drilling layout<br>I<br>I<br>Ø3.07<br>Ø 1.46<br>Ø78<br>4 Ø 0.27 Ø 37<br>4 Ø 7<br>0<br>H4X-06__<br>1.77<br>H12-03__ 45 TEST 0.55 0.55<br>14 14<br>Terminal lugs<br>200 A (LUG1-__) 400 A (LUG2-__)<br>Ø 0.4<br>Ø 4.7<br>0.45<br>Ø11.6<br>2.8 0.63<br>71.5 15.88<br>1.52 0.46<br>38.8 11.68<br>90°<br>90°<br>0.78 20<br>4.92 125 0<br>0.78 20<br>1 25 1.3 35<br>0.25 6.35 1.8 46 0.44 11.13<br>1.12 28.6<br>65°<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
11-68
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
Standard 600 amp Class J and 800 amp Class L
For a complete assembly, select:
||||Switch|||||||
|---|---|---|---|---|---|---|---|---|---|
||||Fuse||Max horsepower rating,3-phase|||||
||||Amps<br>class|Poles<br>SCCR()kA)|220/240<br>440/480<br>600|Catalogno.||||
||Switch + lugs|+<br>Boo{ ~~———~~|600<br>J<br>2<br>200<br>3<br>4<br>800<br>L<br>2<br>3<br>4<br>Terminal lugkit<br>Switch amps<br>Poles<br>Lugsper kit<br>2<br>2<br>~~———~~||-<br>-<br>-<br>200<br>400<br>500<br>200<br>400<br>500<br>-<br>-<br>-<br>200<br>500<br>500<br>200<br>500<br>500<br>Conductor AWG size / type|RDF600J-2<br>RDF600J-3<br>RDF600J-4<br>RDF800L-2<br>RDF800L-3<br>RDF800L-4<br>Catalogno.<br>LUG5-2<br>~~—~~||Disconnect|switches|
||||600-800|3<br>3|(2) 2-600 kcmil<br>75°C Cu/ Al|LUG5-3||||
|||||4<br>4||LUG5-4||||
||||||PLUS|||||
||||Direct mount handle - mounts directly to switch, no shaft required|||||||
|Select for standard application|||For switch cat. no.<br>Color<br>Test<br>function<br>Padlockable<br>Defeatable<br>All switches<br>Black<br>Y<br>Y<br>N<br>OR<br>External front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test<br>function<br>Padlockable<br>Defeatable<br>1, 3R, 4, 4X, 12<br>Black<br>N<br>Y<br>Y<br>Red/yellow<br>Metallic hasp (heavyduty)external front operatedpistol handles - shaft required|||Catalog no.<br>DIR-08<br>Catalog no.<br>H4X-07B<br>H4X-07R||||
|||Or|NEMA<br>type|Color|Test<br>function<br>Padlockable<br>Defeatable|Catalog no.||||
||Handles||1, 3R, 4, 4X, 12|Black<br>Red/yellow|N<br>Y<br>Y|H4X-07BHD<br>H4X-07RHD||||
||||Shafts forpistol handles|||||||
|||+|Length — in(mm)|Mountingdepth(X)— in(mm)||Catalogno.||||
||||7.9 (200)|10.63~11.97 (270~304)||SH7-200||||
||||12.6 (320)|10.63~16.69 (270~424)||SH7-320||||
||||15.7 (400)|10.63~19.84 (270~504)||SH7-400||||
||||||OR|||||
||||NFPA through the door handle kit - to be used with frontpistol handle|||||||
||||For switch cat. no.|Color|Test func-<br>tion<br>Padlockable<br>Defeatable|Catalog no.||||
|||>,|All switches|Red|N<br>Y<br>N|H79-4||||
||||||AND...|||||
||Aux. contacts||Auxiliarycontacts<br>Contact type<br>NO<br>NC|No. of<br>contacts<br>Continuous<br>amprating<br>1<br>10|Voltage<br>(Vac)<br>Max number of aux contacts per<br>switch<br>600<br>8|Catalog no.<br>BAC05<br>BAC06||||
|Accessories|Shrouds|Pate he VEN ||AND...<br>Terminal shrouds - includes terminal shroud for lineside or loadside<br>Switch amps<br>Poles<br>600-800<br>2<br>3|||Catalogno.<br>TSH10-2TB<br>TSH10-3TB||||
||||||4|TSH10-4TB||||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-69
**11 — Disconnect switches**
Dimensions — in (mm)
## RDF600J-3 and RDF800L-3
**==> picture [393 x 204] intentionally omitted <==**
**----- Start of picture text -----**<br>
min 10.43<br>min 265<br>9.84 11.18 (3P) - 14.88 (4P)<br>2506.10 284 (3P) - 378 (4P)<br>2.56 1.34<br>155<br>65 34<br>3.12 0.43<br>79.5 11<br>0.27<br>7 Ø 0.51 0.35<br>Ø 13 9<br>2.32<br>59 2<br>18.58 14.96 51 3.7 3.7<br>472 380 94 94<br>Fuse Cover Fully O pen 14.33 (3P) - 18.03 (4P)<br>364 (3P) - 458 (4P)<br>3.36 85.5<br>7<br>0.27<br>3.54 90 11.81 300 10.23 260 x 9.84 x 250 5 126.5 18.54 471<br>7<br>0.27<br>11.81 300 3.36 85.5<br>**----- End of picture text -----**<br>
## Dir-08 drect mount handle
**==> picture [81 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.36<br>60<br>3.35<br>85<br>7.48 190<br>**----- End of picture text -----**<br>
## External front pistol handle
**==> picture [107 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Direction of front operation<br>**----- End of picture text -----**<br>
**==> picture [233 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
Handle type<br>Ø3.07<br>Ø78 I<br>H4X-07__ 61<br>90°<br>210 0<br>**----- End of picture text -----**<br>
Door drilling layout
**==> picture [99 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø 1.46<br>4 Ø 0.27 Ø 37<br>4 Ø 7<br>0.55 0.55<br>14 14<br>0.78 20<br>0.78 20<br>**----- End of picture text -----**<br>
**==> picture [51 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal lugs<br>**----- End of picture text -----**<br>
## 600 to 800 A (LUG5-__)
**==> picture [241 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.76<br>95.5<br>0.40<br>Ø10.2<br>3.15<br>80<br>11-70 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018<br>1.49 38<br>2.87 73 0.64 16.2<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
**Disconnect switches — 11**
## UL 98 non-fused rotary disconnect switches — 30 to 1200 amps
Bussmann series UL 98 non-fused rotary disconnect switches are versatile switches that “break” and “make” power circuits ON and OFF load.
## Agency information
- UL 98, Guide WHTY, File E155130
- CSA 22.2 No. 4, File 257020
- Conforms with IEC 60947-3
## Features
- Make and break power under load
- Up to 200 kA SCCR
- Panel mount (30-100 A compact DIN-Rail or panel mount)
- Disconnect switches are front, right side and direct handle operable (30-100 A)
- Finger-safe (30-100 A compact only)
- Fully visualized breaking (100-1200 A)
## Online resources
## Related Bussmann series products
## Fuse blocks
Modular Class H(K), J and RK fuse blocks up to 600 A Modular Class H(K), J and RK power distribution fuse blocks up to 400 A Modular, finger-safe CH Class CC and J, and UL supplemental and IEC 10x38mm DIN-Rail holders up to 60 A Finger-safe Optima Class CC, UL supplemental and IEC 10x38mm DINRail/panel mount holders up to 30 A Finger-safe Optima™ Class CC, UL supplemental and IEC 10x38mm DINRail/panel mount protection modules up to 30 A
Visit Eaton.com/bussmannseries for:
- CAD drawings
- Instruction sheets
- UL information
|IEC specifications<br>3-pole<br>4-pole<br>Thermal current I~~th~~ @40°C(A)<br>Rated insulation voltage U~~i~~ (V)<br>Rated impulse withstand voltage U~~imp~~ (kV)<br>Rated operation currents I~~e~~ (A)<br>Rated voltage (Vac)|Load duty<br>category|RD30-3<br>—<br>30<br>800<br>8<br>A1|RD30-3<br>RD60-3<br>—<br>60<br>800<br>8<br>A1|RD30-3<br>RD100-3<br>—<br>100<br>800<br>8<br>A1|RD100-3-SCCR<br>—<br>100<br>1000<br>8<br>A1|RD200-3<br>RD600-3<br>Catalogno.<br>RD200-3<br>RD400-3<br>RD600-3<br>RD800-3<br>RD1000-3<br>RD200-4<br>RD400-4<br>RD600-4<br>RD800-4<br>RD1000-4<br>200<br>400<br>—<br>—<br>—<br>1000<br>1000<br>1000<br>1000<br>1000<br>8<br>8<br>12<br>12<br>12<br>A1<br>A1<br>A1<br>A1<br>A1<br>~~—_~~|RD200-3<br>RD600-3<br>Catalogno.<br>RD200-3<br>RD400-3<br>RD600-3<br>RD800-3<br>RD1000-3<br>RD200-4<br>RD400-4<br>RD600-4<br>RD800-4<br>RD1000-4<br>200<br>400<br>—<br>—<br>—<br>1000<br>1000<br>1000<br>1000<br>1000<br>8<br>8<br>12<br>12<br>12<br>A1<br>A1<br>A1<br>A1<br>A1<br>~~—_~~|RD200-3<br>RD600-3<br>Catalogno.<br>RD200-3<br>RD400-3<br>RD600-3<br>RD800-3<br>RD1000-3<br>RD200-4<br>RD400-4<br>RD600-4<br>RD800-4<br>RD1000-4<br>200<br>400<br>—<br>—<br>—<br>1000<br>1000<br>1000<br>1000<br>1000<br>8<br>8<br>12<br>12<br>12<br>A1<br>A1<br>A1<br>A1<br>A1<br>~~—_~~|RD200-3<br>RD600-3<br>Catalogno.<br>RD200-3<br>RD400-3<br>RD600-3<br>RD800-3<br>RD1000-3<br>RD200-4<br>RD400-4<br>RD600-4<br>RD800-4<br>RD1000-4<br>200<br>400<br>—<br>—<br>—<br>1000<br>1000<br>1000<br>1000<br>1000<br>8<br>8<br>12<br>12<br>12<br>A1<br>A1<br>A1<br>A1<br>A1<br>~~—_~~|RD200-3<br>RD600-3<br>Catalogno.<br>RD200-3<br>RD400-3<br>RD600-3<br>RD800-3<br>RD1000-3<br>RD200-4<br>RD400-4<br>RD600-4<br>RD800-4<br>RD1000-4<br>200<br>400<br>—<br>—<br>—<br>1000<br>1000<br>1000<br>1000<br>1000<br>8<br>8<br>12<br>12<br>12<br>A1<br>A1<br>A1<br>A1<br>A1<br>~~—_~~|RD200-3<br>RD600-3<br>Catalogno.<br>RD200-3<br>RD400-3<br>RD600-3<br>RD800-3<br>RD1000-3<br>RD200-4<br>RD400-4<br>RD600-4<br>RD800-4<br>RD1000-4<br>200<br>400<br>—<br>—<br>—<br>1000<br>1000<br>1000<br>1000<br>1000<br>8<br>8<br>12<br>12<br>12<br>A1<br>A1<br>A1<br>A1<br>A1<br>~~—_~~|RD1200-3<br>RD1200-4<br>—<br>1000<br>12<br>A1|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|400<br>690|AC-22 A<br>AC-23 A<br>AC-22 A<br>AC-23 A|32|63|100<br>80<br>63|100|200|400<br>315|630<br>500<br>200|800<br>630<br>400||1000<br>630<br>400|1200<br>1000<br>630<br>400|
|Operationalpower(Vac)in AC-23(kW)|||||||||||||
|400 V w/oprebreak AC1, 2<br>500 V w/oprebreak AC1, 2||15|30|45|51<br>63|100<br>140|220<br>280|355<br>450|450<br>560||560|560|
|690 V w/oprebreak AC1, 2||18.5|||90|185|185|185|400||400|400|
|Overload capacity (U~~e~~415 Vac)<br>Rated short-circuit makingcapacityI~~cm~~ (kApeak) 3<br>Fuseprotected short-circuit withstand||12|12|12|17.6|32|48|48|75||48|75|
|(kA RMSprospective)|||||||||||||
|Short-circuit current(kA) 3<br>Associated fuse rating (A) 3||50<br>32|50<br>63|25<br>100|200<br>100|200|200<br>400|100<br>630|100<br>800||100<br>1000|100<br>1250|
|Connection|||||||||||||
|Minimum Cu cable cross section(mm2)||2.5|2.5|10|35|70|185|2x150|2x185||2x240|—|
|Minimum Cu busbar section(mm2)||—|—|—|—|—|—|2x30x5|2x40x5||2x50x5|2x60x5|
|Maximum Cu cable section(mm2)||70|70|70|300|300|600|—|—||—|—|
- 1 A/B: Category with index A = frequent operation; category with index B = infrequent operation.
- 2 The power value is given for information only; the current values vary from one manufacturer to another.
- 3 For a rated operating voltage, Ue = 400 Vac.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-71
**11 — Disconnect switches** ~~TN~~
UL specifications
RD30-3
RD200-3
RD600-3
|||||||Catalogno.|Catalogno.|||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|3-pole||RD30-3|RD60-3|RD100-3|RD100-3-<br>SCCR|RD200-3|RD400-3|RD600-3|RD800-3|RD1000-3|RD1200-3|
|4-pole||—|—|—|—|RD200-4|RD400-4|RD600-4|RD800-4|RD1000-4|RD1200-4|
|ULstandard||UL98|UL98|UL98|UL98|UL98|UL98|UL98|UL98|UL98|UL98|
|Maxampacity||30A|60A|100A|100A|200A|400A|600A|800A|1000A|1200A|
|Switchtype||Compact|Compact|Compact|Standard|Standard|Standard|Standard|Standard|Standard|Standard|
|Handle operation||Front/Side|Front/Side|Front/Side|Front|Front|Front|Front|Front|Front|Front|
|ULelectrical ratings||||||||||||
|Max voltage (AC)||600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|600Vac|
|Max voltage (DC)||—|—|—|250Vdc|250Vdc|—|250Vdc|—|—|—|
||1-phase,120|2|3|5|—|—|—|—|—|—|—|
|Max. AC Hp<br>ratings|1-phase,240<br>3-phase,240<br>3-phase,480|5<br>10<br>20|10<br>20<br>40|10<br>20<br>50|10<br>30<br>75|10<br>75<br>150|—<br>125<br>250|—<br>200<br>400|—<br>200<br>500|—<br>200<br>500|—<br>200<br>500|
||3-phase, 600|25|50|50|100|200|350|350|500|500|500|
|DC Hp ratings|125<br>250|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|20<br>50|—<br>—|—<br>—|—<br>—|
|Electricalcharacteristics||||||||||||
|SCCR with fuse (kA)||100|100|25 /100*|200|200|200|200|100|100|100|
|Fuse class||J|J|J|J|J|J|J|L|L|L|
|Max.fuserating (A)||30|60|100|10A|200|400|600|800|1000|1200|
|Terminal lugs/kits||Integral|Integral|Integral|•|•|•|•|•|•|•|
|Lug mounting torque - lb-in<br>(N•m)||—|—|—|160 (18)|160 (18)|LUG2-_ 310 (35)<br>LUG3-_ 398 (45)|310 (35)|310 (35)|310 (35)|310 (35)|
|Wire type||75°C Cu|75°C Cu|75°C Cu|75°C Cu/ Al|75°C Cu/ Al|75°C Cu/ Al|75°C Cu/ Al|75°C Cu/<br>Al|75°C Cu/ Al|75°C Cu/ Al|
||Solid|12-10,<br>35.4(4)|12-10,<br>35.4(4)|12-10,<br>35.4(4)|—|—|—|—|—|—|—|
|Wire range<br>and torque -<br>lb-in (N•m)|Stranded|10-1,<br>35.4 (4)<br>1/0, 39.8<br>(4.5)|10-1,<br>35.4 (4)<br>1/0, 39.8<br>(4.5)|10-1,<br>35.4 (4)<br>1/0, 39.8<br>(4.5)|6-300 kcmil,<br>275 (31)|6-300 kcmil,<br>275 (31)|LUG2-_ 4-600<br>kcmil, 550 (62)<br>Dual 1/0-250<br>kcmil, 550 (62)|(2) 2-600<br>kcmil, 375<br>(42.4)|(4) 2-600<br>kcmil, 375<br>(42.4)|(4) 2-600<br>kcmil, 375<br>(42.4)|(4) 2-600<br>kcmil, 375<br>(42.4)|
|||2/0, 44.3 (5)|2/0, 44.3 (5)|2/0, 44.3<br>(5)|||LUG3-_: (2) 6-2,<br>200 (22.6)|||||
||||||||(2) 1-350 kcmil,<br>375 (42.4)|||||
|Mechanicalcharacteristics||||||||||||
|Endurances/Cycles||10,000|10,000|10,000|10,000|8000|6000|6000|3500|3500|3500|
|Physicalcharacteristics||||||||||||
|Dimensions|||||See drawings onproduct pages|||||||
|Weight - lbs|3-pole|1.3 (0.6)|1.3 (0.6)|1.3 (0.6)|4.2(1.91)|4.2(1.91)|10.0 (4.6)|18.1(8.2)|19.6 (8.9)|19.6 (8.9)|19.6 (8.9)|
|(kg)|4-pole|—|—|—|—|5.0 (2.3)|12.3 (5.6)|23.9 (10.9)|25.3 (11.5)|25.3 (11.5)|25.3 (11.5)|
|Environmental||||||||||||
|Operating Temperature||-20 to 70°C|-20 to 70°C|-20 to<br>70°C|-20 to 70°C|-20 to 70°C|-20 to 70°C|-20 to 70°C|-20 to 70°C|-20 to 70°C|-20 to 70°C|
|FlammabilityRating||UL94-V0|UL94-V0|UL94-V0|UL94-V0|UL94-V0|UL94-V0|UL94-V0|UL94-V0|UL94-V0|UL94-V0|
|Accessories||||||||||||
|Lug kit cat. no.|3-pole<br>4-pole|Integral<br>—|Integral<br>—|Integral<br>—|•<br>—|•<br>•|•<br>•|•<br>•|•<br>•|•<br>•|•<br>•|
||NEMA 1,|•|•|•|•|•|•|—|—|—|—|
||3R,12|||||||||||
||NEMA 1, 3R,|•|•|•|•|•|•|•|•|•|•|
|Handles|4,4X,12<br>Direct|•|•|•|•|•|•|•|•|•|•|
||FrontPistol|•|•|•|•|•|•|•|•|•|•|
||Front or Side|•|•|•|—|—|—|—|—|—|—|
||Selector|||||||||||
|Shaft c/s- mm||5x5|5x5|5x5|10x10|10x10|10x10|12x12|12x12|12x12|12x12|
|Shaft guide||•|•|•|•|•|•|•|•|••|•|
|Shrouds||•|•|•|•|•|•|•|•|•|•|
|Additionalpole accessory||•|•|•|—|—|—|—|—|—|—|
|Auxiliary|NO+ NC|•|•|•|•|•|•|•|•|•|•|
|contacts|(2)NO|•|•|•|—|—|—|—|—|—|—|
- Available, see product page for details and catalog numbers.
- Not available.
- 25 kA @ 600 Vac, 100 kA @ 480 Vac.
Eaton.com/bussmannseries
11-72
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## UL 98 non-fused rotary disconnect switches — 30, 60 and compact 100 A
For a complete assembly, select:
||||||||Switch|
|---|---|---|---|---|---|---|---|
||Switch|||o!)<br>Do.<br>«<br>«<br>e<br>}<br>eTelT. a<br>©<br>led|||Amps<br>Poles<br>SCCR(kA)<br>Max horsepower rating<br>Conductor<br>AWG size/type<br>Catalogno.<br>1-phase<br>3-phase<br>120<br>220/240<br>220/240<br>440/480<br>600<br>30<br>3<br>100<br>2<br>5<br>10<br>20<br>25<br>10-2/0 Str/12-10 Sol<br>75°C Cu<br>RD30-3<br>60<br>3<br>10<br>20<br>40<br>50<br>RD60-3<br>100<br>25/100*<br>5<br>10<br>20<br>50<br>50<br>RD100-3<br>* 100 kA@480 Vac,25 kA@600 Vac.<br>PLUS<br>Direct mount handle - mounts directlyto switch,no shaft required<br>For switch cat. no.<br>Color<br>Test function<br>Padlockable<br>Catalogno.<br>All switches<br>Black<br>N<br>Y - On Switch<br>DIR-02|
||||||||OR|
||||1|2|||External front or right side operated selector handles - shaft required<br>NEMA type<br>Color<br>Handle<br>length<br>Test function<br>Padlockable<br>Catalog no.|
||||||||Black<br>Short<br>H4X-01B(1)|
|Select for standard application|Handles|||Or|||1, 3R, 4, 4X, 12<br>N<br>Y<br>Red/yellow<br>Short<br>H4X-01R(1)<br>Black<br>Long<br>H4X-02B(2)<br>Red/yellow<br>Long<br>H4X-02R(2)<br>External front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Handle<br>length<br>Test function<br>Padlockable<br>Defeatable<br>Catalog no.<br>1, 3R, 4, 4X, 12<br>Black<br>—<br>N<br>Y<br>Y<br>H4X-03B<br>Red/yellow<br>—<br>H4X-03R<br>Metallic hasp (heavyduty)external front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Handle<br>length<br>Test function<br>Padlockable<br>Defeatable<br>Catalog no.<br>1, 3R, 4, 4X, 12<br>Black<br>—<br>N<br>Y<br>Y<br>H4X-03BHD<br>Red/yellow<br>—<br>H4X-03RHD|
|||||+|||Shafts for selector handles|
||||1||||Length — in(mm)<br>Mountingdepth(X)— in(mm)<br>Catalogno.<br>5.9(150)<br>3.50~7.60(89~193)<br>SH4-150(1)|
||||||||7.9(200)<br>3.50~9.50(89~241)<br>SH4-200(1)|
||||||||12.6(320)<br>3.50~14.9(89~378)<br>SH4-320(1)|
||||||||Shafts forpistol handles|
|||||2|||Length — in(mm)<br>Mountingdepth(X)- in(mm)<br>Catalogno.<br>7.9(200)<br>3.30~7.40(84~188)<br>SH3-200(2)<br>12.6(320)<br>3.30~9.30(84~236)<br>SH3-320(2)<br>~~oT~~|
|||||+<br>———|||15.7(400)<br>3.30~14.7(84~373)<br>SH3-400(2)<br>Shaftguide for selector handles<br>Catalogno.<br>Required for 12.6"(320mm)longshafts,optional for other lengths<br>SH-GUIDE1<br> ~~_<—~~|
||||||||Shaftguide forpistol handles|
||||||||Catalogno.|
||||||||Required for 15.7î(400mm)longshafts,optional for other lengths<br>SH-GUIDE2|
||||||||AND...|
||||||||Auxiliarycontacts|
|Accessories|Aux. contacts<br>Shrouds||Contact type<br>No. of contacts<br>Continuous amp<br>rating<br>Voltage (Vac)<br>Max number of units per<br>switch<br>Catalog no.<br>NO + NC<br>1 of each<br>10<br>240<br>2 (1 per side/4 contacts<br>total)<br>BAC01<br>NO<br>2<br>2 (1 per side/4 contacts<br>total)<br>BAC02<br>AND...<br>Terminal shrouds - includes terminal shroud for both lineside and loadside<br>Switch<br>amps<br>Poles<br>Location on switch<br>Catalog no.<br>All switch-<br>es<br>1(for switched 4thpole)<br>Lineside and loadside<br>TSH3-1TB<br>3<br>TSH3-3TB<br>e~~f~~<br>~~E~~<br>~~f~~<br>~~:~~<br>~~—~~<br>~~—~~|||||
||||||||AND...|
||||||||Switched 4th Pole - converts 3-pole switch to 4-pole|
||Sw. 4thpole|||Switch amps<br>Catalog no.<br>30<br>POLE98-30<br>60<br>POLE98-60<br>~~*~~<br>~~|~~<br>~~ee~~<br>t||||
|||||e<br>pa,|||100<br>POLE98-100|
|Auxiliary contact<br>configurations||||Auxiliary contact<br>py<br>Pfelaliol<br>i|||Possible~~4~~th pole<br>configurations<br>~~_~~<br>inal<br>Pu)<br>inva<br>SESs<br>pds<br>WED<br>pa|
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-73
## **11 — Disconnect switches**
Dimensions - in (mm)
Direct handle operation
**==> picture [93 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
External front operation<br>**----- End of picture text -----**<br>
## External right side operation
**==> picture [516 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.95 1.42 3.94 min./14.65 max.<br>75 3.07 36 100 min./372 max.<br>2.5264 2 1 1.027826 1 2 3.19812.52641.9950.6 1 130.511.023.077826 1.18 min./7.91 max.30 min./201 max.1 1.4236<br>2 2<br>0.24<br>0.35 1.02 1.02 1.02 0.35<br>2.09 6 8.8 26 26 26 8.8<br>53 M5 2.08 0.266 0.348.8 1.0226 1.0226 1.0226 0.348.8<br>53 M5<br>4.91 124.6 5.17 131.4 7.44 189<br>2.79 71 4.90 124.6 5.17 131.4 7.44 189 2.79 71<br>**----- End of picture text -----**<br>
1. Position for 1 switched 4[th] pole (1 per device max.) or 1 auxiliary contact.
2. Position for 1 auxiliary contact only. Note: Maximum of 4 Auxiliary contacts, or 3 Auxiliary contacts + one switched 4th pole.
External front/right side operated selector handle, front operated pistol handle
**==> picture [469 x 213] intentionally omitted <==**
**----- Start of picture text -----**<br>
Handle type Door drilling layouts<br>Ø3.07 1.57<br>Ø78 40<br>Direction of Direction of 4 Ø 0.27 0.11<br>4 Ø 7 3<br>Selector front operation right side operation |<br>- H4X-01_ Y 1.4236 I I ~<br>Ø3.07 Ø78 | Ø 1.22<br>Ø 31<br>Ø 0.88<br>- 0 (dy 0 (a With 4 Mounting Screws o Ø 22.5 O With mounting nut<br>SelectorH4X-02_ S&S Lt 1.4537 1.5740<br>4 Ø 0.27<br>4 Ø 7<br>H4X-03_ with 4 mounting screws<br>Pistol<br>H4X-03_<br>Ø 1.45in/37mm screw clip (from front)<br>Ø 1.22in/31mm screw (from rear)<br>90° 90°<br>2.79 71<br>1.10 28 0.53 13.5<br>3.46 88<br>1.10 28<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
11-74
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## er
UL 98 non-fused rotary disconnect switches—100, 200 and compact 400 A For a complete assembly, select:
||Switch|
|---|---|
||Max horsepower rating|
||1-phase<br>3-phase|
|Select for standard application|Switch<br>Amps<br>Poles<br>SCCR(kA)<br>Catalogno.<br>220/240<br>220/240<br>440/480<br>600<br>100<br>3<br>200<br>10<br>30<br>75<br>100<br>RD100-3-SCCR<br>200<br>10<br>75<br>150<br>200<br>RD200-3<br>4<br>10<br>75<br>150<br>200<br>RD200-4<br>400<br>3<br>-<br>125<br>250<br>350<br>RD400-3<br>4<br>-<br>125<br>250<br>350<br>RD400-4<br>+<br>Terminal lugkit<br>Switch<br>amps<br>Poles<br>Lugs per kit<br>Conductor AWG size/type<br>Catalog no.<br>100-200<br>2<br>2<br>6-300 kcmil<br>75°C Cu/ Al<br>LUG1-2<br>3<br>3<br>LUG1-3<br>4<br>4<br>LUG1-4<br>400<br>2<br>2<br>4-600 kcmil or Dual 1/0-250 kcmil<br>75°C Cu/ Al<br>LUG2-2<br>3<br>3<br>LUG2-3<br>4<br>4<br>LUG2-4<br>2<br>2<br>(2) 6-350 kcmil<br>75°C Cu/ Al<br>LUG3-2<br>3<br>3<br>LUG3-3<br>4<br>4<br>LUG3-4<br>PLUS<br>Handle<br>Direct mount handle - mounts directlyto switch,no shaft required<br>For switch cat. no.<br>Color<br>Test<br>function<br>Padlockable<br>Catalog no.<br>All switches<br>Black<br>N<br>Y<br>DIR-03<br>OR<br>External front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test<br>function<br>Padlockable<br>Defeatable<br>Catalog no.<br>1, 3R, 12<br>Black<br>N<br>Y<br>Y<br>H12-03B<br>Red/yellow<br>H12-03R<br>Or<br>1, 3R, 4, 4X, 12<br>Black<br>H4X-06B<br>Red/yellow<br>H4X-06R<br>Metallic hasp (heavyduty)external front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test<br>function<br>Padlockable<br>Defeatable<br>Catalog no.<br>1, 3R, 4, 4X, 12<br>Black<br>N<br>Y<br>Y<br>H4X-06BHD<br>Red/yellow<br>H4X-06RHD<br>+<br>Shafts forpistol handles<br>Length — in(mm)<br>Mountingdepth(X)- in(mm)<br>Catalogno.<br>7.9(200)<br>5.31~10.43(135~265)<br>SH5-200<br>12.6(320)<br>5.31~15.16(135~385)<br>SH5-320<br>15.7(400)<br>5.31~18.31(135~465)<br>SH5-400<br>+<br>Shaft Guide<br>Catalogno.<br>Required for 15.7î (400mm) long shafts, optional for other lengths<br>SH-GUIDE2<br>—~~_—~~<br>SF ~~re~~<br>[<br>~~—_~~<br>~~Ge~~<br>, ~~oo~~<br>— ~~Nc~~<br>P|
||AND...|
||Auxiliarycontacts|
||Aux. contacts<br>Contact<br>type<br>No. of<br>contacts<br>Continuous amp rating<br>Voltage<br>Vac<br>Max number of aux<br>contactsper switch<br>Catalog no.<br>NO + NC<br>1 of each<br>10.1<br>125-250<br>2<br>BAC03*<br>NO + NC<br>BAC04*<br>NO + NC<br>1<br>125<br>BAC11*<br>NO + NC<br>BAC12*|
|Accessories|* For one auxiliarycontact, install either BAC03 or BAC11. For two auxiliarycontacts, install BAC03 + BAC04, or BAC11 + BAC12.<br>AND...<br>Terminal shrouds - includes terminal shroud for Lineside or loadside<br>Switch<br>amps<br>Poles<br>Location on switch<br>Catalog no.|
||Shrouds<br>100-200<br>3<br>Lineside<br>TSH4-3T<br>Loadside<br>TSH4-3B<br>4<br>Lineside or loadside<br>TSH4-4TB<br>400<br>3<br>Lineside<br>TSH5-3T<br>Loadside<br>TSH5-3B<br>~~—~~|
||4<br>Lineside or loadside<br>TSH5-4TB|
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-75
## **11 — Disconnect switches**
Dimensions — in (mm)
**==> picture [296 x 269] intentionally omitted <==**
**----- Start of picture text -----**<br>
M<br>J1 U Z<br>Y 1<br>W<br>R1<br>R2<br>T AD<br>F C<br>CA<br>V<br>K<br>AC<br>N AA<br>H<br>**----- End of picture text -----**<br>
**==> picture [536 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
Switch Overall Terminal shrouds Switch body Switch mounting Connection<br>amps dim. C AC AD F 3p. F 4p. H J1 3p. J1 4p. K M 3p. M 4p. N R1 R2 T U V W Y Z A A AC<br>10.1 7.09 9.06 4.22 2.17 4.13 1.8 6.3 8.27 5.31 0.35 0.27 1.97 0.98 1.18 0.43 0.14 1.35 6.3 0.6<br>100 3.72 (95) 3.05 (78)<br>(256) (180) (230) (107) (55) (105) (46) (160) (210) (135) (9) (7) (50) (25) (30) (11) (4) (34) (160) (15)<br>**----- End of picture text -----**<br>
|amps<br>100|dim.<br>3.72|C<br>(95)|AC<br>10.1<br>(256)|AD<br>3.05 (78)|F 3p.<br>7.09<br>(180)|F 4p.<br>9.06<br>(230)|H<br>4.22<br>(107)|J1 3p.<br>2.17<br>(55)|J1 4p.<br>4.13<br>(105)|K<br>1.8<br>(46)|M 3p.<br>6.3<br>(160)|M 4p.<br>8.27<br>(210)|N<br>5.31<br>(135)|R1<br>0.35<br>(9)|R2<br>0.27<br>(7)|T<br>1.97<br>(50)|U<br>0.98<br>(25)|V<br>1.18<br>(30)|W<br>0.43<br>(11)|Y<br>0.14<br>(4)|Z<br>1.35<br>(34)|A A<br>6.3<br>(160)|AC<br>0.6<br>(15)|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|200|3.72|(95)|10.1<br>(256)|3.05 (78)|7.09<br>(180)|9.06<br>(230)|4.22<br>(107)|2.17<br>(55)|4.13<br>(105)|1.8<br>(46)|6.3<br>(160)|8.27<br>(210)|5.31<br>(135)|0.35<br>(9)|0.27<br>(7)|1.97<br>(50)|0.98<br>(25)|1.18<br>(30)|0.43<br>(11)|0.14<br>(4)|1.35<br>(34)|6.3<br>(160)|0.6<br>(15)|
|400|4.92|(128)|16<br>(406)|4.15 (115)|9.05<br>(230)|11.4<br>(290)|6.53<br>(166)|2.95<br>(75)|5.31<br>(135)|2.65<br>(68)|8.26<br>(210)|10.6<br>(270)|7.67<br>(195)|0.35<br>(9)|0.27<br>(7)|2.56<br>(65)|1.77<br>(45)|1.97<br>(50)|0.43<br>(13)|0.2<br>(5)|2.08<br>(53)|10.2<br>(260)|0.8<br>(20)|
## DIR-03 direct mount handle
## External front handle
**==> picture [515 x 281] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.57 1.79<br>Handle type Direction of front operation Door drilling layout<br>40 45.5<br>I<br>Ø3.07<br>Ø 1.46<br>Ø78<br>4 Ø 0.27 Ø 37<br>4 Ø 7<br>H4X-06__<br>1.77<br>H12-03__ 45 TEST 0.55 0.55<br>14 14<br>Terminal lugs<br>Ø 0.4Ø 4.7 2.31 73.150.88<br>0.45 58.67 0.53<br>Ø11.6 2.8 0.63 13.46<br>1.52 0.46 71.5 15.88<br>38.8 11.68<br>1.19<br>30.23<br>0.25<br>6.35<br>LUG1-_ 100 to 200 A LUG2-_ 400 A LUG3-_ 400 A<br>90°<br>0.78 20<br>5.31 135 4.92 125 0<br>0.78 20<br>1 25 1.3 35<br>1.94 49.30<br>1.12 28.6 0.25 6.35 1.8 46 0.44 11.13 1.25 31.75<br>65°<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
11-76
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
UL 98 non-fused rotary disconnect switches — 600, 800, 1000 and 1200 A
For a complete assembly, select:
||||Switch||
|---|---|---|---|---|
||||Max horsepower rating||
||||SCCR<br>3-phase<br>DC*||
||||Amps<br>Poles<br>(kA)<br>220/240<br>440/480<br>600<br>125<br>250|Catalogno.|
||Switch|600<br>3<br>200<br>240<br>400<br>350<br>20<br>50<br>4<br>240<br>400<br>350<br>20<br>50<br>800<br>3<br>100<br>200<br>500<br>500<br>-<br>-<br>4<br>200<br>500<br>500<br>-<br>-<br>1000<br>3<br>200<br>500<br>500<br>-<br>-<br>4<br>200<br>500<br>500<br>-<br>-<br>1200<br>3<br>200<br>500<br>500<br>-<br>-<br>4<br>200<br>500<br>500<br>-<br>-<br>~~=~~||RD600-3<br>RD600-4<br>RD800-3<br>RD800-4<br>RD1000-3<br>RD1000-4<br>RD1200-3<br>RD1200-4|
|||* DC ratings use twopoles in series.<br>+<br>Terminal lugkit<br>Switch amps<br>Poles<br>Lugs per kit<br>Lugs required per pole<br>Conductor AWG<br>size/type<br>Catalog no.<br>600<br>3<br>3<br>1<br>(2) 2-600 kcmil<br>75°C Cu/ Al<br>LUG5-3<br>4<br>4<br>LUG5-4<br>800-1200<br>3<br>6<br>2<br>(4) 2-600 kcmil<br>75°C Cu/ Al<br>LUG6-6<br>4<br>8<br>LUG6-8<br>—~~_—_——~~|||
|Select for standard application|PLUS<br>Handles<br>Direct mount handle - mounts directlyto switch,no shaft required<br>For switch cat. no.<br>Color<br>Test function<br>Padlockable<br>Catalogno.<br>All switches<br>Black<br>N<br>Y<br>DIR-04<br>OR<br>External front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 4, 4X, 12<br>Black<br>N<br>Y<br>Y<br>H4X-07B(1)<br>Red/yellow<br>H4X-07R(1)<br>Black<br>H4X-08B(2)<br>Red/yellow<br>H4X-08R(2)<br>Or<br>Metallic hasp (heavyduty)external front operatedpistol handles - shaft required<br>NEMA type<br>Color<br>Test function<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 4, 4X, 1<br>Black<br>N<br>Y<br>Y<br>H4X-07BHD(3)<br>Red/yellow<br>H4X-07RHD(3)<br>Black<br>H4X-08BHD(4)<br>Red/yellow<br>H4X-08RHD(4)<br>+<br>Shafts forpistol handles<br>Length — in(mm)<br>Mountingdepth(X)— in(mm)<br>Catalogno.<br>7.9(200)<br>8.70~13.50(221~343)<br>SH6-200<br>12.6(320)<br>8.70~18.23(221~463)<br>SH6-320<br>15.7(400)<br>8.70~21.38(221~543)<br>SH6-400<br>+<br>Shaftguide<br>Catalogno.<br>Required for 15.7" (400mm) long shafts, optional for other lengths<br>SH-GUIDE2<br>1<br>4<br>3<br>2<br>~~2~~<br>7.~~==~~<br>LO<br>2||||
||||AND...||
|Accessories|Aux. contacts|Pe|Auxiliarycontacts<br>Contact type<br>No. of contacts<br>Continuous amp rating<br>Voltage (Vac)<br>Max number of aux contacts<br>per switch<br>NO + NC<br>1 of each<br>10.1<br>125-250<br>2<br>NO + NC<br>1 of each<br>NO + NC<br>1 of each<br>1<br>125<br>NO + NC<br>1 of each<br>* For one auxiliarycontact,install either BAC03 or BAC11. For two auxiliarycontacts,install BAC03 + BAC04,or BAC11 + BAC12.<br>AND...<br>Terminal shrouds* — includes terminal shroud for lineside or loadside|Catalog no.<br>BAC03*<br>BAC04*<br>BAC11*<br>BAC12*|
||||Switch amps<br>Poles<br>Location on switch|Catalogno.|
||Shrouds||600<br>3<br>Lineside or loadside<br>4<br>800-1200<br>3<br>4|TSH6-3TB<br>TSH6-4TB<br>TSH7-3TB<br>TSH7-4TB|
||||* Shroud for lineside included with switch.||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-77
## **11 — Disconnect switches**
**==> picture [300 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions — in (mm)<br>600 A 800 to 1200 A<br>**----- End of picture text -----**<br>
**==> picture [194 x 146] intentionally omitted <==**
**==> picture [150 x 127] intentionally omitted <==**
|Switch<br>amps<br>Terminal<br>shrouds B|Switch body<br>Switch mounting<br>Connection|
|---|---|
||F 3p.<br>F 4p.<br>H<br>J 3p.<br>J 4p.<br>M 3p.<br>M 4p.<br>N<br>N1<br>N2<br>A A<br>Z|
|600<br>18.12 (460)|11 (280)<br>14.17 (360)<br>5.5 (140)<br>5 (128)<br>6.59 (168)<br>10.03 (255)<br>13.19 (335)<br>6.88 (175)<br>2.34 (60)<br>1.1 (28)<br>12.6 (320)<br>1.85 (47)|
|800<br>18.12 (460)|14.64 (372)<br>19.37 (492)<br>5.5 (140)<br>6.83 (174)<br>9.19 (234)<br>13.66 (347)<br>18.38 (467)<br>6.88 (175)<br>2.34 (60)<br>1.1 (28)<br>13 (330)<br>1.85 (47)|
|1000<br>18.12 (460)|14.64 (372)<br>19.37 (492)<br>5.5 (140)<br>6.83 (174)<br>9.19 (234)<br>13.66 (347)<br>18.38 (467)<br>6.88 (175)<br>2.34 (60)<br>1.1 (28)<br>13 (330)<br>1.85 (47)|
|1200<br>18.12 (460)|14.64 (372)<br>19.37 (492)<br>5.5 (140)<br>6.83 (174)<br>9.19 (234)<br>13.66 (347)<br>18.38 (467)<br>6.88 (175)<br>2.34 (60)<br>1.1 (28)<br>13 (330)<br>1.85 (47)|
**==> picture [108 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
DIR-04 Direct mount handle<br>**----- End of picture text -----**<br>
## External front pistol handles
**==> picture [535 x 252] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.36<br>60 Handle Type Direction of Front Operation<br>I<br>Ø3.07<br>Ø78<br>Door drilling layout<br>Ø 1.46<br>3.35 H4X-07__ 2.4 4 Ø 0.274 Ø 7 Ø 37<br>85 61<br>Terminal lugs<br>I<br>Ø3.07<br>Ø78 0.55 0.55<br>14 14<br>0<br>H4X-08__ 2.36<br>60<br>90°<br>90°<br>7.48 190 0<br>8.27 210<br>0.78 20<br>0.78 20<br>13.78 350<br>**----- End of picture text -----**<br>
LUG5-__, LUG6-__ 600 to 1200 A
**==> picture [238 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
3.76<br>95.5<br>0.40<br>Ø10.2<br>3.15<br>80<br>11-78 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018<br>1.49 38<br>2.87 73 0.64 16.2<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
**Disconnect switches — 11**
## UL 508 non-fused rotary disconnect switches — 16 to 80 A
Eaton UL 508 load break disconnect switches allow safe control and safe disconnection of any motor application or to isolate a circuit within the panel.
These disconnect switches are compact and offer a wide variety of accessories like 4th poles, Auxiliary contacts, door mounting and 6/8-Pole kits.
## Features
- Suitable for motor disconnect
- DIN-Rail or panel mount
- Door mount option
- Disconnect switches are front, right side or direct handle operable
- Finger-safe
Agency information
- UL 508, Guide NLRV, File E155129
- CSA C22.2 No. 14, File 257020
- Conforms with IEC 60947-3
## Online resources
Visit Eaton.com/bussmannseries for:
- CAD drawings
Related Bussmann series products
~~eee~~ Fuse blocks Modular Class H(K), J and RK fuse blocks up to 600 A Modular Class H(K), J and RK power distribution fuse blocks up to 400 A Modular, finger-safe CH Class CC and J, and UL supplemental and IEC 10x38mm DIN-Rail holders up to 60 A
Finger-safe Optima Class CC, UL supplemental and IEC 10x38mm DINRail/panel mount holders up to 30 A
Finger-safe Optima™ Class CC, UL supplemental and IEC 10x38mm DINRail/panel mount protection modules up to 30 A
- Instruction sheets
- UL information
IEC specifications RD16-3-508 RD16-3-508 with 6-pole conversion kit
|Catalogno.<br>RD16-3-508<br>RD25-3-508<br>RD40-3-508<br>RD63-3-508<br>RD80-3-508<br>~~ee~~|Catalogno.<br>RD16-3-508<br>RD25-3-508<br>RD40-3-508<br>RD63-3-508<br>RD80-3-508<br>~~ee~~|Catalogno.<br>RD16-3-508<br>RD25-3-508<br>RD40-3-508<br>RD63-3-508<br>RD80-3-508<br>~~ee~~|Catalogno.<br>RD16-3-508<br>RD25-3-508<br>RD40-3-508<br>RD63-3-508<br>RD80-3-508<br>~~ee~~|Catalogno.<br>RD16-3-508<br>RD25-3-508<br>RD40-3-508<br>RD63-3-508<br>RD80-3-508<br>~~ee~~|Catalogno.<br>RD16-3-508<br>RD25-3-508<br>RD40-3-508<br>RD63-3-508<br>RD80-3-508<br>~~ee~~|
|---|---|---|---|---|---|
|Thermal current I~~th~~at 40°C(A)|16|25|40|63|80|
|Rated insulation voltage U~~i~~ (V)|800|800|800|800|800|
|Rated impulse withstand voltage U~~imp~~ (kV)<br>Rated operation currents Ie(A)|8|8|8|8|8|
|Load dutycategory<br>Rated voltage|A/B1|A/B1|A/B1|A/B1|A/B1|
|500<br>AC-22 A/ AC-22 B<br>AC-23A/ AC-23 B|16/16<br>16/16|25/25<br>25/25|40/40<br>25/25|63/63<br>63/63|80/80<br>63/63|
|AC-21 A/ AC-21 B|16/16|25/25|40/40|63/63|80/80|
|690<br>AC-22 A/ AC-22 B|16/16|25/25|32/40|40/63|63/80|
|AC-23A/ AC-23 B|16/16|25/25|25/25|40/40|40/40|
|Operationalpower in AC-23(kW)||||||
|400 Vac withoutprebreak AC1, 2|7.5|11|18.5|30|37|
|500 Vac withoutprebreak AC1, 2|7.5|11|15|30|37|
|690 Vac withoutprebreak AC1, 2|7.5|15|18.5|30|37|
|Overload capacity (U~~e~~415 Vac)<br>Rated short-time withstand current 0.3 s. ICW (kA<br>RMS) 3|2.5|2.5|2.5|3|3|
|Rated short-time makingcapacityI~~cm~~ (kApeak) 3<br>6<br>Fuseprotected short-circuit withstand(kA RMSprospective)||6|6|9|9|
|Prospective short-circuit current(kA RMS) 3|50|50|50|50|50|
|Associated fuse rating (A) 3|16|25|40|63|80|
|Connection||||||
|Minimum Cu cable cross section(mm2)|1.5|1.5|1.5|2.5|2.5|
|Maximum Cu cable section(mm2)|16|16|16|35|35|
|Tighteningtorque min/max(N•m)|2/2.2|2/2.2|2/2.2|3.5/3.85|3.5/3.85|
- 1 A/B: Category with index A = frequent operation; category with index B = infrequent operation.
- 2 The power value is given for information only; the current values vary from one manufacturer to another.
- 3 For a rated operating voltage, Ue = 400 Vac.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-79
**11 — Disconnect switches**
## UL specifications
|UL specifications|UL specifications|‘On<br>3<br>Lt||||©<br>ve<br>mon|ee.|©<br>ve<br>mon|ee.|
|---|---|---|---|---|---|---|---|
|RD16-3-508<br>Catalogno.||‘On<br>3<br>Lt<br>eee|RD16-3-508 with 6-pole conversion kit<br>RD16-3-508<br>RD25-3-508<br>RD40-3-508|||RD63-3-508<br>RD80-3-508<br>©<br>ve<br>mon | ee.<br>oSrenbeet?||
|UL standard|||UL 508|UL 508|UL 508|UL 508|UL 508|
|Max ampacity|||16 A|25 A|40 A|63 A|80 A|
|Handle operation|||Front/Side|Front/Side|Front/Side|Front/Side|Front/Side|
|UL ratings||||||||
|Max voltage(AC)|||600 Vac|600 Vac|600 Vac|600 Vac|600 Vac|
||3-phase,208||3|7.5|7.5|15|15|
|Max. Hp ratings|3-phase,240<br>3-phase,480||5<br>10|7.5<br>15|7.5<br>20|20<br>40|20<br>40|
||3-phase,600||10|20|25|40|40|
|Electrical characteristics||||||||
|SCCR with fuse(kA)|||65|65|10/65|50/65|50/65|
|Recommended upstream|Fuse class<br>Max. fuse rating (A)||J<br>30|J<br>30|J<br>60/30|J<br>100/60|J<br>100/60|
|Terminals|||Integral|Integral|Integral|Integral|Integral|
|Wire type|||75°C Cu|75°C Cu|75°C Cu|75°C Cu|75°C Cu|
||Solid single||14-10,26.5(3)|14-10,26.5(3)|14-10,26.5(3)|14-10,31.1(3.5)|14-10,31.1(3.5)|
|Wire range and torque - lb-in|Solid dual||12,26.5(3)|12,26.5(3)|12,26.5(3)|12,31.1(3.5)|12,31.1(3.5)|
|(N•m)|Stranded single||14-4,26.5(3)|14-4,26.5(3)|14-4,26.5(3)|14-1,31.1(3.5)|14-1,31.1(3.5)|
||Stranded dual||14-12,26.5(3)|14-12,26.5(3)|14-12,26.5(3)|10-6,31.1(3.5)|10-6,31.1(3.5)|
|Mechanical characteristics||||||||
|Endurances/cycles|||10,000|10,000|10,000|10,000|10,000|
|Physical characteristics||||||||
|Dimensions||||See drawings onproductpages||||
|Weight- lb(kg)|||0.5(0.2)|0.5(0.2)|0.5(0.2)|0.7(0.32)|0.7(0.32)|
|Environmental||||||||
|Operatingtemperature|||-20 to 70°C|-20 to 70°C|-20 to 70°C|-20 to 70°C|-20 to 70°C|
|Flammabilityrating|||UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|UL 94-V0|
|Accessories||||||||
||Direct||DIR-01|DIR-01|DIR-01|DIR-01|DIR-01|
||Short selector/NEMA 1, 3R, 4,||H4X-01B|H4X-01B|H4X-01B|H4X-01B|H4X-01B|
||4X, 12||H4X-01R|H4X-01R|H4X-01R|H4X-01R|H4X-01R|
||Long selector/NEMA 1, 3R, 4,||H4X-02B|H4X-02B|H4X-02B|H4X-02B|H4X-02B|
|Handles|4X, 12||H4X-02R|H4X-02R|H4X-02R|H4X-02R|H4X-02R|
||Pistol handle/NEMA 1, 3R, 4,||H4X-03B|H4X-03B|H4X-03B|H4X-03B|H4X-03B|
||4X, 12||H4X-03R|H4X-03R|H4X-03R|H4X-03R|H4X-03R|
||Metallic hasp (HD) pistol handle/||H4X-03BHD|H4X-03BHD|H4X-03BHD|H4X-03BHD|H4X-03BHD|
||NEMA 1, 3R, 4, 4X, 12||H4X-03RHD|H4X-03RHD|H4X-03RHD|H4X-03RHD|H4X-03RHD|
||5.9"/150mm||SH4-150|SH4-150|SH4-150|SH4-150|SH4-150|
|Selector handle shafts - 5x5mm|7.9"/200mm||SH4-200|SH4-200|SH4-200|SH4-200|SH4-200|
||12.6"/320mm||SH4-320|SH4-320|SH4-320|SH4-320|SH4-320|
||7.9"/200mm||SH3-200|SH3-200|SH3-200|SH3-200|SH3-200|
|Pistol handle shafts - 5x5mm|12.6"/320mm||SH3-320|SH3-320|SH3-320|SH3-320|SH3-320|
||15.75"/400mm||SH3-400|SH3-400|SH3-400|SH3-400|SH3-400|
|Selector handle shaftguide|||SH-GUIDE1|SH-GUIDE1|SH-GUIDE1|SH-GUIDE1|SH-GUIDE1|
|Pistol handle shaftguide|||SH-GUIDE2|SH-GUIDE2|SH-GUIDE2|SH-GUIDE2|SH-GUIDE2|
|Door mount kit|||DOOR-508|DOOR-508|DOOR-508|DOOR-508|DOOR-508|
||1-Pole||TSH1-1TB|TSH1-1TB|TSH1-1TB|—|—|
||3-Pole(loadside and lineside)||TSH1-3TB|TSH1-3TB|TSH1-3TB|TSH2-3TB|TSH2-3TB|
||Switched 4thpole/switch amps||POLE-16|POLE-25|POLE-40|—|—|
|Shrouds/switch amps|Ground module (conforms to IEC<br>60947-3)||GND-16-40|GND-16-40|GND-16-40|GND-63-80|GND-63-80|
||Neutral module (conforms to IEC<br>60947-3)||NTRL-16-40|NTRL-16-40|NTRL-16-40|NTRL-63-80|NTRL-63-80|
||NO + NC(1 ea.)||BAC01|BAC01|BAC01|BAC01|BAC01|
||(2)NO||BAC02|BAC02|BAC02|BAC02|BAC02|
|Auxiliary contacts|AC ratings|||||||
||Volts||240 Vac|240 Vac|240 Vac|240 Vac|240 Vac|
||Amps||10|10|10|10|10|
|6-/8-pole conversion kit gangs two switches of same rating, 16-80 A|||KIT-6POLE|KIT-6POLE|KIT-6POLE|KIT-6POLE|KIT-6POLE|
|switch amps||||||||
- Not available.
Eaton.com/bussmannseries
11-80
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## ABST
## UL 508 non-fused rotary disconnect switches —16, 25, 40, 63 and 80 A
For a complete assembly, select:
|||Switch|||
|---|---|---|---|---|
|||Max. Class<br>Max horsepower rating, 3-Phase|||
|||Amps<br>Poles<br>SCCR @600V<br>(kA)<br>J fuse<br>amps<br>Conductor AWG size/<br>type<br>Catalogno.<br>208<br>220/240<br>440/480<br>600|||
||Switch|16<br>3<br>65<br>30<br>3<br>5<br>10<br>10<br>14-10 Sol, Dual 12<br>Sol, 14-4 Str, Dual<br>14-12 Str, 75°C Cu<br>RD16-3-508<br>25<br>7.5<br>7.5<br>15<br>20<br>RD25-3-508<br>40<br>10<br>60<br>7.5<br>7.5<br>20<br>25<br>RD40-3-508<br>65<br>30<br>63<br>50<br>100<br>15<br>20<br>40<br>40<br>14-10 Sol, Dual 12<br>Sol, 14-1 Str, Dual<br>10-6 Str, 75°C Cu<br>RD63-3-508<br>65<br>60<br>80<br>50<br>100<br>15<br>20<br>40<br>40<br>RD80-3-508<br>65<br>60<br>PLUS|Disconnect|switches|
|||Direct mount handle - mounts directlyto switch,no shaft required<br>Forswitchcat.no.<br>Color<br>Testfunction<br>Padlockable<br>Catalogno.<br>All switches<br>Black<br>N<br>Y - On Switch<br>DIR-01<br>@|||
|Select for standard application|Handles|OR<br>External front or right side operated selector handles-shaftrequired<br>NEMAtype<br>Color<br>Handlelength<br>Testfunction<br>Padlockable<br>Catalogno.<br>1, 3R, 4, 4X, 12<br>Black<br>Short<br>N<br>Y<br>H4X-01B(1)<br>Red/yellow<br>H4X-01R(1)<br>Black<br>Long<br>H4X-02B(2)<br>Red/yellow<br>H4X-02R(2)<br>Or<br>External front operated pistol handles-shaftrequired<br>NEMAtype<br>Color<br>Handlelength<br>Testfunction<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 4, 4X, 12<br>Black<br>—<br>N<br>Y<br>Y<br>H4X-03B<br>Red/yellow<br>H4X-03R<br>Metallichasp (heavy duty) external front operated pistol handles-shaftrequired<br>NEMAtype<br>Color<br>Handlelength<br>Testfunction<br>Padlockable<br>Defeatable<br>Catalogno.<br>1, 3R, 4, 4X, 12<br>Black<br>—<br>N<br>Y<br>Y<br>H4X-03BHD<br>Red/yellow<br>H4X-03RHD<br>+<br>Shaftsforselector handles<br>Length — in(mm)<br>Mounting depth(X)- in(mm)<br>Catalogno.<br>5.9 (150)<br>3.50~7.60 (89~193)<br>SH4-150 (1)<br>7.9 (200)<br>3.50~9.50 (89~241)<br>SH4-200 (1)<br>12.6 (320)<br>3.50~14.9 (89~378)<br>SH4-320 (1)<br>Shaftsforpistol handles<br>Length — in(mm)<br>Mounting depth(X)- in(mm)<br>Catalogno.<br>7.9 (200)<br>3.30~7.40 (84~188)<br>SH3-200 (2)<br>12.6 (320)<br>3.30~9.30 (84~236)<br>SH3-320 (2)<br>15.7(400)<br>3.30~14.7(84~373)<br>SH3-400 (2)<br>+<br>Shaft guidesforselectorand pistol handles<br>Handle type<br>Catalogno.<br>Selector<br>Requiredfor 12.6"(320mm)long shafts, optional forother lengths<br>SH-GUIDE1<br>Pistol<br>Required for 15.7" (400mm) long shafts, optional for other lengths<br>SH-GUIDE2<br>+<br>Door mount kit<br>For mounting switch on the right side of the enclosure or directly on the enclosure door using switch side operation shaft location. Kit<br>includes a shaft. Orderswitchand selector handle separately.<br>Switch<br>Catalogno.<br>All switches - kit includes shaft<br>DOOR-508<br>1<br>2<br>1<br>2<br>ee.~~,rtrti‘OSCSC;CO™~OC~~<br>Se~~———————————————————~~<br>— ~~_V—__—_————~~<br>eT ~~————~~<br>~~a~~<br>_~~,_-_.jjQQgec=~~|||
AND...
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-81
## **11 — Disconnect switches**
||Aux.Contacts||Auxiliary contacts<br>Contact type<br>No. of<br>contacts<br>Continuous amp<br>rating<br>Voltage (Vac) rating<br>NO+ NC<br>1 Ea.<br>10<br>240<br>NO<br>2<br>6~~—~~<br>e|Auxiliary contacts<br>Contact type<br>No. of<br>contacts<br>Continuous amp<br>rating<br>Voltage (Vac) rating<br>NO+ NC<br>1 Ea.<br>10<br>240<br>NO<br>2<br>6~~—~~<br>e|Auxiliary contacts<br>Contact type<br>No. of<br>contacts<br>Continuous amp<br>rating<br>Voltage (Vac) rating<br>NO+ NC<br>1 Ea.<br>10<br>240<br>NO<br>2<br>6~~—~~<br>e|Max number of units per switch<br>2 (1 per side/4 contacts total)|Max number of units per switch<br>2 (1 per side/4 contacts total)|Catalog no.<br>BAC01<br>BAC02<br>~~——~~|Catalog no.<br>BAC01<br>BAC02<br>~~——~~|
|---|---|---|---|---|---|---|---|---|---|
||||||AND...|||||
||||||Terminalshrouds- includes terminalshroudforboth lineside andloadside|||||
||Shrouds||||Switch<br>amps<br>Poles<br>16-40<br>1(forswitched4thpole)<br>16-40<br>3<br>63-80||Location on switch<br>Lineside and loadside||Catalog no.<br>TSH1-1TB<br>TSH1-3TB<br>TSH2-3TB|
||||||AND...|||||
||||||Switched4thpole-converts 3-pole switchto4-pole switch|||||
|Accessories|4thpole||||Switchamps<br>16<br>25<br>40<br>AND...||||Catalogno.<br>POLE-16<br>POLE-25<br>POLE-40|
||||||Ground andNeutral Modules-provides unswitched ground or neutralpole-conforms toIE|IEC 60947-3||||
||Gnd./neut. mods||||Switchamps<br>ModuleType<br>16-40<br>Ground<br>63-80<br>16-40<br>Neutral<br>63-80||||Catalogno.<br>GND-16-40<br>GND-63-80<br>NTRL-16-40<br>NTRL-63-80|
||||||AND...|||||
||||||6-pole conversion kit-creates a 6-pole switchby ganging two 3-pole switches ofequal rating|||||
||6 pole kit||Switchamps<br>Catalogno.<br>Allswitches<br>KIT-6POLE*<br>* Kit ships with a direct handle. If external handle is needed order a selector handle and shaft for the UL 508 Rotary Disconnect<br>Switches.<br>Note: To create an 8-pole switch from 16 to 40 amp switches, use two 3-pole switches of equal ratings plus two switched 4th poles<br>(part # POLE-_).<br>siete<br>|olele z!~~Ono~~<br>ie|||||||
Order switches separately
**==> picture [530 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
Auxiliary contact Ground and neutral module, and<br>configurations switched 4 [th] pole configurations.<br>Sciciag opi s fa l e fel l as pa o oegf e c pat s pi e s op e<br>Dimensions — in (mm)<br>2.95 1.42 E F D 1.42<br>752.52 F 1 36 3.19812.52 M 36<br>64 1 M 2 641.99 J 1 2<br>2 50.6 1<br>2<br>Nd 0.24 0.35 F1 LA smn T F1 0.35 PU iO 2 ele}o © ~<br>1.97 6 8.8 M5 8.8<br>50 0.236 0.358.8 F1 T F1 0.358.8<br>1.96<br>- | | sl 50 si M5<br>Direct handle operation External front operation External side operation<br>1. Position for 1 switched 4 [th] pole (1 per device max.), or ground or neutral module (2 per device max.) or 1 auxiliary contact.<br>2. Position for 1 auxiliary contact only.<br>Note: Maximum of 4 Auxiliary contacts, or 3 Auxiliary contacts + one ground or neutral module, or one switched 4 [th] pole.<br>N or G N or G N or G N or G N or G N or G<br>G 2.67 68 N AC<br>G 2.68 68 N AC ø 2.79 ø 71<br>**----- End of picture text -----**<br>
|Switch||Overall dimensions|Overall dimensions||Terminal||Switch body|Switch body||Switch mountin|Switch mounting||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|amps|D min|D max|E min|E max|shroud AC|F|F1|G|J|M|N|Connection T|
|16 to 40|1.18 (30)|9.25 (235)|3.94 (100)|14.64 (372)|4.33 (110)|1.77 (45)|0.59 (15)|2.67 (68)|0.59 (15)|1.18 (30)|2.95 (75)|0.59 (15)|
|63 to 80|1.18 (30)|9.25 (235)|3.93 (100)|14.64 (372)|4.33 (110)|2.06 (53)|0.69 (18)|2.99 (76)|0.69 (18)|1.38 (35)|3.35 (85)|0.69 (18)|
Eaton.com/bussmannseries
11-82
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
Dimensions — in (mm)
**==> picture [534 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
F F<br>J 3.50 J<br>F2 89 F2<br>om 2 1 X I M 2.0652.5 1 2 3.0778 ne 2 1 ——| X M 2.0652.5 1 2 E 1.4236<br>0.24<br>0.358.8 F1 Be T en T [tae 0.29 F1 0.358.8 6 i) 1.6943 34.71.36 0.358.8 F1 ee T T rr 0.29 F1 0.358.8 i<br>midalli 2.06 7.5 : min 2.06 7.5<br>52.5 52.5<br>N G 2.67 68 1.77 45 N G 2.67 68 ø 2.79 ø 71<br>**----- End of picture text -----**<br>
Direct front operation for 6/8-pole disconnects
External front operation for 6/8-pole disconnects
1. Position for 1 switched 4th pole (1 per device max.) or 1 auxiliary contact.
2. Position for 1 auxiliary contact only.
Note: Maximum of 4 auxiliary contacts, or 3 auxiliary contacts + one switched 4th pole.
|Switch<br>amps|Overall dimensions<br>E min<br>E max<br>F|Overall dimensions<br>E min<br>E max<br>F|Overall dimensions<br>E min<br>E max<br>F|F1|Switch body<br>F2<br>G|Switch body<br>F2<br>G|J|Switch mounting<br>M|Switch mounting<br>N|Connection<br>T<br>X|Connection<br>T<br>X|
|---|---|---|---|---|---|---|---|---|---|---|---|
|16 to 40|4.13 (105)|14.64 (372)|3.83 (98)|0.59 (15)|1.77 (45)|2.67 (68)|1.92 (48.75)|1.18 (30)|2.95 (75)|0.59 (15)|0.29 (8)|
|63 to 80|4.13 (105)|14.65 (372)|4.13 (105)|0.69 (18)|2.06 (53)|2.99 (76)|2.06 (52.5)|1.38 (35)|3.35 (85)|0.69 (18)|0.34 (9)|
External selector and pistol handles
**==> picture [536 x 244] intentionally omitted <==**
**----- Start of picture text -----**<br>
Handle type Door drilling layouts<br>Ø3.07 1.57<br>Ø78 40<br>Direction of Direction of 4 Ø 0.27 0.11<br>4 Ø 7 3<br>Selector front operation right side operation<br>H4X-01_ A 1.4236 I I o- ©<br>Ø3.07 ! ! cp | ame<br>— Ø78 Ø 1.22<br>Ø 31<br>Ø 0.88<br>0 0 With 4 Mounting Screws Ø 22.5 With mounting nut<br>eS <== OS<br>Selector 1.45 i| 1.57<br>H4X-02_ 37 i 40<br>iH 11it on<br>4 Ø 0.27<br>4 Ø 7<br>& <5)<br>6 @:: o c H4X-03_ with 4 mounting screws<br>Pistol S Os<br>H4X-03_<br>Ø 1.45in/37mm screw clip (from front)<br>Ø 1.22in/31mm screw (from rear)<br>90° 90°<br>2.79 71<br>1.10 28 0.53 13.5<br>3.46 88<br>1.10 28<br>**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-83
**11 — Disconnect switches**
## UL 98 and UL 508 enclosed disconnect switches
Enclosed fused and non-fused rotary disconnect switches from 16 to 1200 A in NEMA 1, 3R, 4, 4X, 12 enclosures.
## Ratings
- Volts
**==> picture [28 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- 600 Vac
- 250-600 Vdc*
- Amps 16-1200 A
- SCCR
- UL 98 25-200 kA
NEMA 1, 3R, 4 and 12
- UL 508 10-65 kA
* Some non-fused disconnect switches are not rated for DC applications.
## Agency information
- UL 98 Listed, Guide WIAX, WIAX7, File E182262
- UL 508 Listed, Guide NLRV, NLRV, File E155129
- cULus Listed to Canadian Standard 22.2, No. 14
- cULus Listed to Canadian Standard 22.2, No. 4
- Conforms with IEC 60947-3
- RoHS compliant
- CE
## Operating temperature
NEMA 4X 304 stainless steel
- -20ºC to 70ºC
4X plastic enclosure flammability ratings
- Polycarbonate UL 94-5V A-0
- Fiberglass UL 94-5V
## Field installed accessories
- Auxiliary contacts
- Terminal shrouds
- Switched 4[th] pole (UL 508 only)
NEMA 4X polycarbonate or fiberglass
## Online resources
Visit Eaton.com/bussmannseries for:
- CAD drawings
- Instruction sheets
- UL information
## Features
- UL 98 Listed for general purpose, main disconnect, or branch circuit protection up to 600 Vac/dc
- UL 508 Listed for motor disconnect applications up to 600 Vac
- Multiple field installed accessories enhance the enclosed disconnect switches to fit the desired application
- Lockout/tagout: Up to three 1/4" shank padlocks can be installed on external handles
Eaton.com/bussmannseries
11-84
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
||||||||||**Disconnect switches —11**|**Disconnect switches —11**|||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|UL 98 enclosed fused disconnects — 30 to 800 A|||||UL 98 enclosed fused disconnects — 30 to 800 A||||||||
|3-pole UL 98 600 Vac<br>Catalog number system:<br>ER<br>4X<br>-<br>60<br>J<br>3<br>P<br>B<br>ER<br>Enclosed Rotary disconnect<br>NEMA rating<br>1, 3R, 4, 4X (304 SST), 4P (4X Plastic), 12<br>Amp rating<br>30, 60, 100, 200, 400, 600, 800<br>Fuse class<br>J = Class J, L = Class L<br>Number of poles<br>3 = 3-pole<br>Handle type<br>P = Pistol<br>Handle color<br>NEMA 1, 3R, 4 and 12<br>NEMA 4X<br>304 stainless steel<br>NEMA 4X<br>30-800A UL 98 fused switches<br>Available Bussmann series fuses<br>Fuse class<br>Catalogsymbol/type<br>J<br>LPJ time-delay,current limiting<br>JKS fast-actingfuses<br>DFJ high speed drive fuse<br>L<br>KRP-C time-delay,current limiting<br>KTU fast-acting<br>~~=~~|||||||||||Disconnect|switches|
|B = Black, R = Red|||||||||KLU time-delay<br>KRP-CL(225-600 A)||||
|Catalog numbers|||||||||||||
|All catalog numbers provided with integral or installed lugs and a|||||All catalog numbers provided with integral or installed lugs and a||||||||
|black selector handle. Order Red/yellow handle by changing the|||||||||||||
|suffix “B” to “R.”|||||||||||||
||||NEMA enclosure type and catalogno.||||||||||
|Switch amps<br>Fuse class||||1||3R||4|4Xplastic1<br>4X 304 stainless|12|||
|30||||ER1-30J3PB||ER3R-30J3PB||ER4-30J3PB|ER4P-30J3PB<br>ER4X-30J3PB|ER12-30J3PB|||
|60||||ER1-60J3PB||ER3R-60J3PB||ER4-60J3PB|ER4P-60J3PB<br>ER4X-60J3PB|ER12-60J3PB|||
|J<br>100<br>200||||ER1-100J3PB<br>ER1-200J3PB||ER3R-100J3PB<br>ER3R-200J3PB||ER4-100J3PB<br>ER4-200J3PB|ER4P-100J3PB<br>ER4X-100J3PB<br>ER4P-200J3PB<br>ER4X-200J3PB|ER12-100J3PB<br>ER12-200J3PB|||
|400||||ER1-400J3PB||ER3R-400J3PB||ER4-400J3PB|ER4P-400J3PB<br>ER4X-400J3PB|ER12-400J3PB|||
|600||||ER1-600J3PB||ER3R-600J3PB||ER4-600J3PB|ER4P-600J3PB<br>ER4X-600J3PB|ER12-600J3PB|||
|800<br>L||||ER1-800L3PB||ER3R-800L3PB||ER4-800L3PB|ER4P-800L3PB<br>ER4X-800L3PB|ER12-800L3PB|||
1 Enclosures ≤100 A are polycarbonate, flammability rating UL 94-5V A-V0, ≥200 A are fiberglass, flammability rating UL 94-5V.
## Switch ratings
For wire types, ranges and terminal torques, see table on page 11-55.
|||||Voltage|||
|---|---|---|---|---|---|---|
|Switch amps|Switch cat. no.|Fuse class<br>Poles|Vac|Vdc|SCCR@Vac(kA)|Max. Hp @600 Vac|
|30|RDF30J-3|||||20|
|60|RDF60J-3|||250||50|
|100<br>200|RDF100J-3<br>RDF200J-3|J<br>3|600|N/A|200|75<br>150|
|400|RDF400J-3|||250||350|
|600|RDF600J-3||||||
|||||600||500|
|800|RDF800L-3|L|||||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-85
**11 — Disconnect switches** TON
UL 98 enclosed fused disconnects — 30 to 800 A W Enclosure weights and dimensions a Catalog no. Fuse NEMA Mounting centers h x w (in) family Amps class enclosure H x W x D (in) A B C Weight (lbs) MH H 1, 3R, 4, 12 10x10x6 8.3x8.3 — — 15 A ER_-30J 30 4X-SST — 10.7x8.3 8.3x10.7 4X-plastic[1] — 12x5.6 7.6x10 8 ~~a=~~ 1, 3R, 4, 12 12x10x6 10.3x8.3 — — 19 | ER_-60J 60 4X-SST — 12.7x8.3 8.3x10.7 MW ~~ae~~ 4X-plastic[1] 13x13x6 — 14x7.6 9.6x12 11 1, 3R, 4, 12 14x12x6 12.3x10.3 — — 21 W ER_-100J 100 4X-SST — 14.7x10.3 12.3x12.7 ~~—_—_~~ 4X-plastic[1] 13x13x6 — 14x7.6 9.6x12 12 J 1, 3R, 4, 12 24x20x8 22.3x18.3 — — 55 ER_-200J 200 4X-SST — 24.7x18.3 22.3x20.7 4X-plastic[1] 27x21x10 — 25.75x14 — 39 B H MH 1, 3R, 4, 12 48x36x12 46.3x34.3 — — 188 ER_-400J 400 4X-SST — 48.7x34.3 46.3x36.7 4X-plastic[1] 51x37x14 — 50x28.5 — 186 ~~ee~~ ER_-600J 600 1, 3R4X-SST, 4, 12 48x36x12 46.3x34.3— 48.7x34.3— 46.3x36.7— 216 || MW 4X-plastic[1] 51x37x14 — 50x28.5 — 214 W 1, 3R, 4, 12 48x36x12 46.3x34.3 — — 216 ER_-800L 800 L 4X-SST — 48.7x34.3 46.3x36.7 4X-plastic[1] 51x37x14 — 50x28.5 — 214 1 Enclosures ≤100 A are polycarbonate, flammability rating UL 94-5V A-V0, ≥200 A are fiberglass, flammability rating UL 94-5V. C MH H Available field-Installed accessories - order separately Auxiliary contacts - for 30 to 800 amp switches il Contact type No. of contacts Cont. amp rating Vac Max. units per switch Catalog no. MW NO 4 (30 to 200 A) BAC05 1 10 600 NC 8 (400 to 800 A) BAC06 ~~——~~ Terminal shrouds For 200 to 800 amp switches - includes terminal shroud for lineside or loadside
|Switch amps|Poles|Catalogno.|
|---|---|---|
|200||TSH8-3TB|
|400|3|TSH9-3TB|
|600-800||TSH10-3TB|
Eaton.com/bussmannseries
11-86
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
UL 98 enclosed non-fused disconnects — 30 to 1200 A
3-pole UL 98 600 Vac Catalog number system:
ER 4X - 60 N 3 P B
ER Enclosed Rotary disconnect NEMA rating 1, 3R, 4, 4X (304 SST), 4P (4X Plastic), 12 Amp rating 30, 60, 100, 200, 400, 600, 800, 1200
N = non-fused Number of poles 3 = 3-pole Handle type P = Pistol Handle color B = Black, R = Red
NEMA 1, 3R, 4 and 12
NEMA 4X 304 stainless steel
NEMA 4X
200-1200A UL 98 non-fused switches
NEMA 1, 3R, 4 and 12
NEMA 4X NEMA 4X 304 stainless steel
30-800A UL 98 non-fused switches
## Catalog numbers
All Catalog numbers provided with integral or installed lugs and a black selector handle. Order Red/yellow handle by changing the suffix “B” to “R.”
||||NEMA enclosure type and catalogno.|NEMA enclosure type and catalogno.|||
|---|---|---|---|---|---|---|
|Amps|1|3R|4|4Xplastic1|4X 304 stainless|12|
|30|ER1-30N3PB|ER3R-30N3PB|ER4-30N3PB|ER4P-30N3PB|ER4X-30N3PB|ER12-30N3PB|
|60|ER1-60N3PB|ER3R-60N3PB|ER4-60N3PB|ER4P-60N3PB|ER4X-60N3PB|ER12-60N3PB|
|100|ER1-100N3PB|ER3R-100N3PB|ER4-100N3PB|ER4P-100N3PB|ER4X-100N3PB|ER12-100N3PB|
|200|ER1-200N3PB|ER3R-200N3PB|ER4-200N3PB|ER4P-200N3PB|ER4X-200N3PB|ER12-200N3PB|
|400|ER1-400N3PB|ER3R-400N3PB|ER4-400N3PB|ER4P-400N3PB|ER4X-400N3PB|ER12-400N3PB|
|600|ER1-600N3PB|ER3R-600N3PB|ER4-600N3PB|ER4P-600N3PB|ER4X-600N3PB|ER12-600N3PB|
|800|ER1-800N3PB|ER3R-800N3PB|ER4-800N3PB|ER4P-800N3PB|ER4X-800N3PB|ER12-800N3PB|
|1200|ER1-1200N3PB|ER3R-1200N3PB|ER4-1200N3PB|N/ A|ER4X-1200N3PB|ER12-1200N3PB|
1 Enclosures ≤100 A are polycarbonate, flammability rating UL 94-5V A-V0, ≥200 A are fiberglass, flammability rating UL 94-5V.
## Switch ratings
For wire types, ranges and terminal torques, see table on page 11-72.
|Amps<br>Switch catalogno.<br>Poles<br>Vac<br>SCCR(kA)<br>Max. Hp@ 600 Vac<br>~~eee~~|Amps<br>Switch catalogno.<br>Poles<br>Vac<br>SCCR(kA)<br>Max. Hp@ 600 Vac<br>~~eee~~|Amps<br>Switch catalogno.<br>Poles<br>Vac<br>SCCR(kA)<br>Max. Hp@ 600 Vac<br>~~eee~~|Amps<br>Switch catalogno.<br>Poles<br>Vac<br>SCCR(kA)<br>Max. Hp@ 600 Vac<br>~~eee~~|Amps<br>Switch catalogno.<br>Poles<br>Vac<br>SCCR(kA)<br>Max. Hp@ 600 Vac<br>~~eee~~|Amps<br>Switch catalogno.<br>Poles<br>Vac<br>SCCR(kA)<br>Max. Hp@ 600 Vac<br>~~eee~~|
|---|---|---|---|---|---|
|30|RD30-3||||25|
|||||100||
|60|RD60-3|||||
||||||50|
|100|RD100-3|||25/100*||
|200|RD200-3||||200|
|||3|600|||
|400|RD400-3|||200||
||||||350|
|600|RD600-3|||||
|800|RD800-3|||||
|||||100|500|
|1200|RD1200-3|||||
* 25 kA @ 600 Vac, 100 kA @ 480 Vac.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-87
**11 — Disconnect switches** ~~7~~
|UL 98 enclosed non-fused disconnects —<br>30 to 1200 A<br>Enclosure weights and dimensions<br>Catalog<br>no. family<br>Amps<br>NEMA<br>enclosure<br>H x W x D(in)<br>Mountingcenters h x w(in)<br>Weight(lbs)<br>A<br>B<br>C<br>ER_-30<br>30<br>1,3R,4,12<br>10x8x6<br>8.3x6.3<br>—<br>—<br>11<br>4X-SST<br>—<br>10.7x6.3<br>8.3x8.7<br>11<br>4X-plastic(1)<br>9x9x6<br>—<br>10x3.6<br>5.6x8<br>5<br>ER_-60<br>60<br>1,3R,4,12<br>10x8x6<br>8.3x6.3<br>—<br>—<br>12<br>4X-SST<br>—<br>10.7x6.3<br>8.3x8.7<br>12<br>4X-plastic(1)<br>9x9x6<br>—<br>10x3.6<br>5.6x8<br>5<br>ER_-100<br>100<br>1,3R,4,12<br>12x10x6<br>10.3x8.3<br>—<br>—<br>12<br>4X-SST<br>—<br>12.7x8.3<br>8.3x10.7<br>12<br>4X-plastic(1)<br>13x13x6<br>—<br>14x7.6<br>9.6x12<br>8<br>ER_-200<br>200<br>1,3R,4,12<br>20x16x8<br>18.3x14.3<br>—<br>—<br>39<br>4X-SST<br>—<br>20.7x14.3<br>18.3x16.7<br>39<br>4X-plastic(1)<br>20x17x12<br>—<br>21.5x10.1<br>31<br>ER_-400<br>400<br>1,3R,4,12<br>36x30x8<br>34.3x28.3<br>—<br>—<br>122<br>4X-SST<br>—<br>36.7x28.3<br>34.3x30.7<br>122<br>4X-plastic(1)<br>37x32x14<br>—<br>38x28.9<br>—<br>103<br>ER_-600<br>600<br>1,3R,4,12<br>48x36x12<br>46.3x34.3<br>—<br>—<br>209<br>4X-SST<br>—<br>48.7x34.3<br>46.3x36.7<br>209<br>4X-plastic(1)<br>51x37x 14<br>—<br>50x28.5<br>—<br>187<br>ER_-800<br>800<br>1,3R,4,12<br>48x36x12<br>46.3x34.3<br>—<br>—<br>211<br>4X-SST<br>—<br>48.7x34.3<br>46.3x36.7<br>211<br>4X-plastic(1)<br>51x37x 14<br>—<br>50x28.5<br>—<br>189<br>ER_-1200<br>1200<br>1,3R,4,12<br>60x36x16<br>60x36x16<br>58.3x34.3<br>—<br>—<br>268<br>4X-SST<br>—<br>60.7x34.3<br>58.3x36.7<br>268<br>W<br>W<br>W<br>MW<br>MW<br>MW<br>H<br>H<br>H<br>MH<br>MH<br>MH<br>A<br>B<br>C<br>~~a~~<br>~~es~~| |<br>~~SE~~<br>~~a~~<br>-<br>ll<br>il<br>~~oe~~|
|---|
|1 Enclosures ≤100 A are polycarbonate, flammability rating UL 94-5V A-V0, ≥200 A are fiberglass, flammability rating UL 94-5V.|
Available field-installed accessories - order separately
Auxiliary contacts for 30 to 1200 amp switches.
|Switch amps<br>Contact type|No. of contacts|Cont. amprating|Vac|Max. unitsper switch<br>Catalogno.|
|---|---|---|---|---|
|NO + NC|1 of each|||BAC01*|
|30-100||10|240|4|
|NO|2|||BAC02*|
|NO + NC|1 of each|||BAC03**|
|NO + NC|1 of each|10.1|125-250|BAC04**|
|200-1200<br>NO + NC|1 of each|||2<br>BAC11**|
|NO + NC|1 of each|1|125|BAC12**|
- Two (2) Units per switch max.
- ** For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.
Terminal shrouds for 200 to 800 amp switches
|Terminal shrouds for 200 to 800 amp switches|Terminal shrouds for 200 to 800 amp switches|Terminal shrouds for 200 to 800 amp switches|Terminal shrouds for 200 to 800 amp switches|Terminal shrouds for 200 to 800 amp switches|
|---|---|---|---|---|
|Switch amps<br>Poles<br>Location on switch<br>Catalogno.<br>30-100<br>Lineside and loadside<br>TSH3-3TB<br>~~—E={Z~~<br>~~ooo~~|||||
||||Lineside|TSH4-3T|
||200||||
||||Loadside|TSH4-3B|
|||3|Lineside|TSH5-3T|
|400<br>600<br>e~~R~~|||Loadside<br>Lineside or loadside|TSH5-3B<br>TSH6-3TB|
||800-1200|||TSH7-3TB|
Eaton.com/bussmannseries
11-88
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Disconnect switches — 11**
## UL 508 enclosed non-fused disconnect — 16 to 80 A
3-/6-pole UL 508 600 Vac Catalog number system:
ER 4X - 63 N 6 P B ER Enclosed Rotary disconnect NEMA rating 1, 3R, 4, 4X (304 SST), 4P (4X Plastic), 12 Amp rating 16, 25, 40, 63, 80 N = non-fused Number of poles 3 = 3-pole, 6 = 6-pole Handle type S = Selector*, P = Pistol** Handle color
NEMA 1, 3R, 4 and 12 NEMA 4X NEMA 4X 304 stainless steel
**==> picture [125 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
16-80 A UL 508 non-fused switches<br>**----- End of picture text -----**<br>
B = Black, R = Red
- 6-Pole switches only, selector handle does not interlock the enclosure door.
- ** 3-pole switches only.
## Catalog numbers
All catalog numbers provided with a black selector handle. Order red/ yellow handle by changing the suffix “B” to “R.”
||||NEMA enclosure and catalogno.|NEMA enclosure and catalogno.|||
|---|---|---|---|---|---|---|
|Amps<br>Poles|1|3R|4|4Xplastic1|4X 304 stainless|12|
|3|ER1-16N3PB|ER3R-16N3PB|ER4-16N3PB|ER4P-16N3PB|ER4X-16N3PB|ER12-16N3PB|
|16|||||||
|6|ER1-16N6SB|ER3R-16N6SB|ER4-16N6SB|ER4P-16N6SB|ER4X-16N6SB|ER12-16N6SB|
|3|ER1-25N3PB|ER3R-25N3PB|ER4-25N3PB|ER4P-25N3PB|ER4X-25N3PB|ER12-25N3PB|
|25|||||||
|6|ER1-25N6SB|ER3R-25N6SB|ER4-25N6SB|ER4P-25N6SB|ER4X-25N6SB|ER12-25N6SB|
|3|ER1-40N3PB|ER3R-40N3PB|ER4-40N3PB|ER4P-40N3PB|ER4X-40N3PB|ER12-40N3PB|
|40|||||||
|6|ER1-40N6SB|ER3R-40N6SB|ER4-40N6SB|ER4P-40N6SB|ER4X-40N6SB|ER12-40N6SB|
|3|ER1-63N3PB|ER3R-63N3PB|ER4-63N3PB|ER4P-63N3PB|ER4X-63N3PB|ER12-63N3PB|
|63|||||||
|6|ER1-63N6SB|ER3R-63N6SB|ER4-63N6SB|ER4P-63N6SB|ER4X-63N6SB|ER12-63N6SB|
|3|ER1-80N3PB|ER3R-80N3PB|ER4-80N3PB|ER4P-80N3PB|ER4X-80N3PB|ER12-80N3PB|
|80|||||||
|6|ER1-80N6SB|ER3R-80N6SB|ER4-80N6SB|ER4P-80N6SB|ER4X-80N6SB|ER12-80N6SB|
1 Polycarbonate enclosure flammability rating UL 94-5V A-V0.
## Switch ratings
For wire types, ranges and terminal torques, see table on page 11-80.
|For wire types, ranges and terminal torques, see table on page 11-80.|For wire types, ranges and terminal torques, see table on page 11-80.|For wire types, ranges and terminal torques, see table on page 11-80.|For wire types, ranges and terminal torques, see table on page 11-80.|For wire types, ranges and terminal torques, see table on page 11-80.|For wire types, ranges and terminal torques, see table on page 11-80.|
|---|---|---|---|---|---|
|Amps<br>Switch catalogno.<br>Vac<br>SCCR with max upstream Class J fuse<br>Max. Hp@ 600 V<br>16<br>RD16-3-508<br>10<br>~~fo~~<br>~~T—“C™tisSCSSSCSCSC“‘“‘CN’NNCNWNWNWNWCS“CWN~~||||||
|||||65 kA /30 A||
||25|RD25-3-508|||20|
||40|RD40-3-508|600|65 kA /30 A — 10 kA / 60 A|25|
||63|RD63-3-508||65 kA /60 A — 50 kA / 100 A|40|
||80|RD80-3-508||50 kA / 100 A|40|
Note: Voltage, SCCR and horsepower ratings are the same for 3- and 6-pole switches.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-89
**11 — Disconnect switches**
UL 508 enclosed non-fused disconnect — 16 to 80 A
W
Enclosure weights and dimensions
Enclosure weights and dimensions NEMA Switch Mounting centers h x w (in) enclosure Poles amps H x W x D (in) A B C Weight (lbs) A MH H 3 8x6x6 6.3x4.3 — — 8 1, 3R, 4, 12 6 10x8x6 8.3x6.3 — — 11 3 16-80 8x6x6 — 8.7x4.3 6.3x6.7 8 || ~~TL:~~ 4X-304 SST 6 10x8x6 — 10.7x6.3 8.3x8.7 11 MW 3 16-63 7.4x8.7x5.8 — 8x3.6 3.6x8 4 W 4X-plastic[1] 80 9.4x8.7x5.9 — 10x3.6 5.6x8 5 ~~OO~~ 6 16-8 A 11.4x10.7x6.3 — 12x5.6 7.6x10 6 _
1 Polycarbonate.
|Available field-installed accessories - order separately|Available field-installed accessories - order separately|Available field-installed accessories - order separately|Available field-installed accessories - order separately|||||B|||H<br>MH|H<br>MH|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||
||||||||||||||
|||No. of<br>Cont.<br>amp||||||MW|||||
|Contact type<br>contacts<br>rating<br>Vac<br>Max. unitsper switch<br>Catalogno.<br>NO + NC<br>1 Ea.<br>10<br>240<br>2 (1 per side, 4 contacts total)<br>BAC01<br>NO<br>2<br>BAC02<br>Auxiliary contact<br>configurations<br>W<br>H<br>MH<br>C<br>~~=~~<br>PS<br>a)|||||||||||||
Available field-installed accessories - order separately
## Auxiliary contacts
## Terminal shrouds
MW
Includes terminal shroud for both lineside and loadside.
|Switch amps<br>Poles|Location on switch<br>Catalog no.|
|---|---|
|16-40|TSH1-3TB|
|3|Lineside and loadside|
|63-80|TSH2-3TB|
## Switched 4[th] pole
Converts 3-pole switch to 4-pole switch.
|Switch amps|Catalog no.|
|---|---|
|16|POLE-16|
|25|POLE-25|
|40|POLE-40|
Eaton.com/bussmannseries
11-90
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Quik-Spec™ electrical gear — 12**
## Contents
## Bussmann series Quik-Spec[TM] Coordination Panelboard
**==> picture [254 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Section|
|Description|page|
|Quik-Spec™ Coordination Panelboards|
|QSCP Up to 400 A|2|
|QSCP 600 to 1200 A|3|
|Quik-Spec elevator disconnects|
|Power Module™ switches and panels|4-5|
|HVAC disconnects|
|Fused, non-fused, GFCI|6|
**----- End of picture text -----**<br>
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
12-1
**12 — Quik-Spec™ electrical gear**
## 30-400A Quik-Spec™ Coordination Panelboard (QSCP)
Configurable 600 Vac fused panelboard with from 30 to 400 amp mains, 15 to 200 amp 1-, 2- and 3-pole disconnect switches and 18, 30, 42, 60, 72, or 84 branch circuit positions. Finger-safe fused branch circuit switches use the time-delay or fast-acting CUBEFuse available in ratings from 1 to 200 amps.
## Ratings
- Volts
- Up to 600 Vac
- Up to 125 Vdc *
- Amps 30, 60, 100, 200, 225 or 400 A
- SCCR
- 200 kA, 100 kA or 50 kA AC
- 100 kA or 20 kA@125 Vdc*
- Vdc rating applicable to MLO panels only. 50 and 60 amp switches are rated 125 Vdc for installed fuse amp ratings up to 40 A and 24 Vdc for installed fuse amp ratings from 45 to 60 A. 90 and 100 amp switches are rated 125 Vdc for installed fuse amp ratings up to 80 A and 24 Vdc for installed fuse amp ratings from 90 to 100 A.
## Agency information
- UL Listed to UL 67
## Mains
- MLO (main lug only)
- Fused disconnect
- Non-fused disconnect
## Enclosure**
- NEMA 1 (top or bottom feed)
- NEMA 3R (bottom feed only)
- Consult factory for other ratings (NEMA 4X and 12)
- ** Standard size 20" W x 5" D x various heights, depending on configuration. Flush mount and door-in-door not available with NEMA 3R enclosure.
## Mounting
- Surface – NEMA 1 and 3R
- Flush – NEMA 1 only
## Doors
- Single - NEMA 1 and 3R
- Door-in-Door – NEMA 1 only
## Branch positions
## Loadside lugs and disconnect
- Feed-through single and double
- Fused loadside disconnect, ≥100 to ≤200 amp (400 amp panels only)
## Neutrals
- 200, 400 and 800 A CCP2B 3-pole branch unbonded and bonded switch features lockout provision for 1/4" lock
## Ground
- Non-isolated or isolated
## Features
- UL Listed and cULus to Canadian Standard 22.2, No. 29-M1989 make it easy to address NEC and CEC selective coordination requirements in an all fused system or upstream Eaton circuit breakers
- Same size footprint as traditional circuit breaker panelboards and 40% smaller than standard fusible panelboards: 20" W x 5-3/4" D x various heights (depending on configuration)
- Increased safety with the current-limiting finger-safe Class CF CUBEFuse that helps reduce arc flash hazard levels
## Optional surge protection
NEC 700.8 requires a listed SPD to be installed in or on all emergency system panelboards.
Any QSCP intended for installation on an AC circuit can be ordered with an Surge Protective Device to comply with NEC 700.8.
The installed SPDs feature a remote Form C contact relay (rated at 250 Vac/0.5 A ) for easy integration into a monitoring system.
## Ordering
The QSCP is factory configured to the specific electrical system. To place your order, contact your Bussmann series product distributor or representative and provide the relevant electrical and circuit information for your installation.
## Accessories
CCP2B-60-LOD - Lock on device for Compact Circuit Protector up to 60 amps
The lock on device (CCP2B-60-LOD) ensures the ON state of a CCP2B switch used in fire alarm circuits and other critical circuit applications.
This device allows for compliance with NEC, UL and CE code requirements for fire alarm circuits and can accommodate a padlock to prevent the operation of the switch.
- 18, 30, 42, 60, 72, and 84 (factory configured)
## Branch switches
- 1-, 2- and 3-pole amp rating rejecting CCP2B fused switches[†] (field installable)
- Amp rejection breaks 15, 20, 30, 40, 50, 60, 70, 90, 100 A
- CCP2Bs will not accept a fuse with a greater amp rating than the switch.
|Catalogno.|Description|Compatible<br>CCP2B||
|---|---|---|---|
|CCP2B-60-LOD|Lock on<br>device<br>for select<br>CCP2B|CCP2B-X-15CF*<br>CCP2B-X-20CF*<br>CCP2B-X-30CF*<br>CCP2B-X-40CF*||
||bases|CCP2B-X-50CF*||
|||CCP2B-X-60CF*||
|*(X = 1,2,3 poles)|||Set screw size:|
||||5/64”x3/8”, 8-32 thread|
|• Lock Shackle Size = ¼” dia. max|Lock Shackle Size = ¼” dia. max||Allen wrench size: 5/64”|
- *(X = 1,2,3 poles)
- Lock Shackle Size = ¼” dia. max
- Flammability rating of lock on device PA12-GB nylon resin = 94V-0
Data sheet no. 1160
Data sheet no. 11323
Eaton.com/bussmannseries
12-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Quik-Spec™ electrical gear — 12**
## 600-1200A Quik-Spec Coordination Panelboard (QSCP)
Configurable fused panelboard with 600, 800 and 1200 amp MLO mains and branch switches up to 600 amps.
## Ratings
- Volts
- Up to 600 Vac
- Up to 125 Vdc
- Amps 600, 800, 1200 A
- SCCR 200 kA
## Agency information
- UL Listed to UL 67
## Assembly
- Main lug only
- Floor mount NEMA 1 enclosure
- Branch switches 1-, 2- and 3-pole, 15 to 600 A
## Available branch switch fuses
- Fast-acting or time-delay Class J (time-delay LPJ or fast-acting JKS) non-CCP2B disconnects only
- High speed DFJ Class J fuses (non-CCPB disconnects only)
- Fast-acting or time-delay Class CF (time-delay TCF or fast-acting FCF) CCP2B disconnects only
## Features
- Configurable panelboards with options for 600, 800 and 1200 A MLO mains and branches from 15-600 A all rated 200 kA SCCR at 600 Vac
- The CCP2B finger-safe branch switches (utilizing the UL Class CF CUBEFuse up to 100 A) features amp rating rejection to help prevent overfusing
- Fused switches make it simple to address NEC selective coordination system requirements in an all fused system or with upstream Eaton circuit breakers.
## Ordering
The QSCP is factory configured to the specific electrical system. To place your order, contact your Bussmann series product distributor or representative and provide the relevant electrical and circuit information for your installation.
Configuration and dimensions — in
|Panel<br>amps|Panel<br>amps|Branch configurations|H|W|D|||
|---|---|---|---|---|---|---|---|
|||(18) 1-100 A<br>(18) 1-100 A + 200 A single<br>~~sss~~||||||
||600|(18) 1-100 A + 200 A twin<br>200 A single + 200 A single<br>200 A single + 200 A twin<br>200 A twin + 200 A twin|65|27|15|||
|||(2) 300 A single|89|38|15|||
|||(18) 1-100 A + 200 A single||||||
|||(18) 1-100 A + 200 A twin|65|38|15|||
||800|(2) 200 A twin<br>(18) 1-100 A + 400 A single<br>200 A twin + 400 A single|89|38|15|Quik-Spec|Electrical gear|
|||(2) 400 A single||||||
|||(18) 1-100 A + 600 A single||||||
|||(3) 200 A twin||||||
||||89|38|15|||
|||200 A twin + 600 A single||||||
||1200|(2) 200 A twin + 400 A single<br>(3) 400 A single||||||
|||600 A single + 400 A single + 200 A single<br>600 A single + 400 A single + 200 A twin|102|38|15|||
|||(2) 600 A single||||||
## Accessories
CCP2B-60-LOD - Lock on device for Compact Circuit Protector Bases up to 60 amps
The lock on device (CCP2B-60-LOD) ensures the ON state of a CCP2B switch used in fire alarm circuits and other critical circuit applications. This device allows for compliance with NEC, UL and CE code requirements for fire alarm circuits and can accommodate a padlock to prevent the operation of the switch.
|Catalogno.|Description|Compatible<br>CCP2B<br>CCP2B-X-15CF*||
|---|---|---|---|
|CCP2B-60-LOD|Lock on<br>device<br>for select<br>CCP2B|CCP2B-X-20CF*<br>CCP2B-X-30CF*<br>CCP2B-X-40CF*||
||bases|CCP2B-X-50CF*|Set screw size:|
|||CCP2B-X-60CF*|5/64”x3/8”, 8-32 thread|
||||Allen wrench size: 5/64”|
- *(X = 1,2,3 poles)
- Lock Shackle Size = ¼” dia. max
- Flammability rating of lock on device PA12-GB nylon resin = 94V-0
Data sheet no. 1171
Data sheet no. 11323
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
12-3
**12 — Quik-Spec™ electrical gear**
## Quik-Spec Power Module switch and panel all-in-one elevator disconnects
Fused power switch (PS) or panel (PMP) with shunt trip and fire safety interface provide a single point tie in with fire alarm systems.
## Ratings
- Volts 600 Vac, 3Ø
- Amps*
- 30-400 A (PS)
- 30-200 A (PMP feeder switches)
- 400-800 A (PMP main switches)
PS[†] Power Module Switch for single elevator applications.
- SCCR 200 kA RMS
- Contact your Bussmann series product representative for applications greater than 800 amps.
## Agency information
- Power Module switch (PS) — UL Listed (UL 98) enclosed and dead front switch Guide 96NK3917, File E182262, NEMA 1, UL 50 Listed enclosure**, cUL per Canadian Standards C22.2, No. 0-M91-CAN/CSA C22.2, No. 4-M89 Enclosed switch.
- Power Module Panel (PMP) — UL 98 enclosed and deadfront switches, complies with NFPA 70
- ** NEMA 12, 3R, and 4 enclosures also available.
## Elevator shutdown
- ANSI/ASME A17.1, 2.8.3.3.2
- NEC 620.51(B) (elevator shutdown)
- NEC 240.12 (orderly shutdown)
- Shunt trip voltage monitoring
- NFPA 72, 6.16.4.4
## Selective coordination
PMP[†] Power Module Panel for multiple elevator applications.
- NEC 620.62
## Auxiliary contact (hydraulic elevator)
- NEC 620.91(C)
## Features
- Internally powered, relay activated shunt trip system
- Mechanically interlocked auxiliary contact
- Self-contained adherence to elevator consensus standards, NFPA 70, NFPA 72, ANSI/ASME A17.1
- Shunt trip capability
- Fire safety signal interface
† Fused main disconnect requires Class J fuses, not supplied with switch.
## Typical applications
- Elevator disconnects
- Computer room shunt trip disconnect
- Fire safety interface relay
## Accessories
- For added safety, use the Bussmann series SAMI™ fuse covers to improve maintenance personnel protection (OSHA 1910.333, Paragraph C)
## Ordering
- Shunt trip voltage monitoring
- Component protection with Low-Peak™ Class J fuses
- Lockable in the open position with three-lock capability
- Optional key-test switch and optional pilot light for easy inspection
- The Quik-Spec Power Module Switch and Panel are factory configured. To place your order, have all relevant electrical and circuit information contact your Bussmann series product representative.
- No annual calibration or testing of overcurrent protection required
- Padlockable for service-work safety and open-door “override” for troubleshooting
## Data sheet no. 1145 (switch) 1146 (panel)
Eaton.com/bussmannseries
12-4 BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Quik-Spec™ electrical gear — 12**
## Hydraulic elevators
Hydraulic elevators need battery backup to help prevent stranding passengers. To keep the elevator from moving when it’s been manually shut down for maintenance, the NEC requires battery backup be connected to the elevator disconnecting means through an auxiliary contact.
However, an unintended consequence can be passengers getting stranded because of devices that open automatically (circuit breakers and disconnects utilizing a molded case switch with a trailing fuse block) will operate with a fault on their loadside. That operation also disables the battery backup and strands passengers. That’s why the Power Module has a non-automatic fusible shunt trip switch. If the Power Module has a fault on its loadside, the fuses open and the battery stays enabled. Thus the Power Module ensures that battery power is enabled when the passengers need it to exit - and disabled to allow safe maintenance of the elevator and hoistway.
**==> picture [264 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
Offered<br>Offered by other<br>Battery by elevator<br>lowering Power discon-<br>Scenario required Reason Module nects<br>**----- End of picture text -----**<br>
|Power<br>failure|Yes|Need to lower elevator<br>and allow passengers<br>to exit.|Yes|Yes|
|---|---|---|---|---|
|Fire in<br>shaft or<br>machine<br>room|No|Recall is initiated by<br>smoke detector and<br>lowers elevator to a<br>safe floor. Battery not<br>needed.|Yes|Yes|
|Disconnect<br>manually<br>opened|No|Worker to perform<br>maintenance. Elevator<br>must remain stationary<br>to prevent injury.|Yes|Yes|
|Fault on<br>loadside of<br>disconnect|Yes|Need to lower elevator<br>and allow passengers<br>to exit.|Yes|No|
Power Module Switch catalog number system
To order, use this build-a-code to specify your Power Module switch.
PS 1 T48 R1 K G N1 B F1 U PS = Power Module Switch Amp rating[†]
- 3 = 30, 6 = 60, 1 = 100 2 = 200, 4 = 400
- Control transformer*[†]
- T20 = 208 V, T24 = 240 V T48 = 480 V, T60 = 600 V
- Fire safety interface relay (3PDT, 10A, 12V)[†]
- R1 = 120 Vac coil, R2 = 24 Vdc coil
Optional key test switch
- K = Key
Optional pilot light ON
- G = Green, R = Red W = White
Optional neutral lug[††]
- N6 = 30-60 A, N1 = 100 A N2 = 200 A, N4 = 400 A
Auxiliary contacts[†]
- B = 2 NO/NC
Fire alarm voltage monitoring relay (to monitor shunt trip voltage)
- F1 = Single-pole, F3 = Three-pole**
## QuikShip service program, 3 days for switches and 10 days for panels!
Ship-direct service within three business days for Power Module switches (PS_) and 10 business days for Power Module panels (PMP_).
||Power Module switch*||
|---|---|---|
|Catalog no.|Amps|Volts|
|PS6T48R1KGBF3-X|60|480|
|PS1T48R1KGBF3-X|100|480|
|PS1T20R1KGBF3-X|100|208|
|PS2T48R1KGBF3-X|200|480|
|PS2T20R1KGBF3-X|200|208|
||Power Module panel**||
|Catalog no.||Amps|
|PMP-400-X||400|
|PMP-600-X||600|
|PMP-800-X||800|
Optional NEMA enclosures (Type 1 standard with no suffix designation required)
- U = Type 3R, Y = Type 4, Z = Type 12
- 100 Va with primary and secondary fusing (120 V secondary).
- ** Only for use with R1 option.
- Required equipment.
- †† Neutral lug rating should be equal to or greater than the switch amp rating.
- Three day PS_ shipment requires ordering from catalog numbers shown, limit three units or less per order.
- ** 10 day PMP_ shipment covers NEMA 1 enclosures with the amp ratings shown and all requirements for relay type (AC or DC), accessory options and number of switches. To order PMP_, contact your Bussmann series product representative with all relevant electrical and circuit information.
Data sheet no. 1145 (switch) 1146 (panel)
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
12-5
**12 — Quik-Spec™ electrical gear**
## Fused and non-fused HVAC disconnects
## Dimensions
Fused and non-fused pullout HVAC disconnects in NEMA 3R enclosures. Fused versions are available in 30 and 60 amp ratings with or without selftesting GFCI receptacles. Nonfused versions are available in 60 amp versions with or without self-testing GFCI receptacles.
## Ratings
- Volts
- 120 Vac single-phase
Fused disconnect
Non-fused disconnect
- See catalog numbers table
## Features
- HVAC disconnects meet National Electrical Code (NEC[®] ) requirements 404.30, 440.11, and 440.14
- Self-testing GFCI units meet UL 943 and NEC requirements under articles 210.63, 210.8, and 406.9(B)(1)
- Padlockable with two-position pullout handle to lock safety shield when in the ON position. (Not available on GFCI or 60 A switched units.) For added safety, pullout handle can be stored in the compartment in the OFF position
- Weather-resistant enclosures withstand outdoor environment
- 240 Vac split-phase
- Amps 30 or 60 A
- Horsepower rated (see catalog numbers table)
Non-fused disconnect with GFCI receptacle
## Agency Information
Metallic and non-metallic
- cULus Listed
Conductors - AWG
Non-metallic non-fused disconnect
- 3-14 Cu/Al
## Enclosure
- Metallic NEMA 3R enclosure with weather-resistant coating
## Applications
Intended for indoor/outdoor use, subject to the below limitations:
- All wiring must comply with state and local electrical codes, including the NEC and/or Canadian Electrical Code
- This unit contains no serviceable parts
- 60 A HVAC disconnects are designed and listed in compliance to UL 1429
- Intended for use with lower load compressors with intermittent operation, pursuant to the NEC/NFPA 70
- This HVAC disconnect is not intended for use on electric vehicle (EV) charging, photovoltaic, and resistive heating applications. Eaton recommends disconnect switch B222-60NFNA for these applications.
- Non-metaliic PPE (polyphenylene ether) weather-resistant plastic enclosure
|Catalogno.|Description|Amp<br>rating|Max Hprating<br>120 V<br>240 V|Fuse<br>class|Approximate dimensions (in)<br>Height<br>Width<br>Depth|Approximate dimensions (in)<br>Height<br>Width<br>Depth|Approximate dimensions (in)<br>Height<br>Width<br>Depth|
|---|---|---|---|---|---|---|---|
|Fused disconnects||||||||
|B221-30F|Pullout disconnect||||8-3/4|5-3/8|2-7/8|
|B221-30FGFWTST|Pullout disconnect with weather-resistant/<br>tamper-resistant rated GFCI|30|1.5<br>3|H or R|13|7-1/2|4-3/4|
|B222-60F|Pullout disconnect||||8-3/4|5-3/8|2-7/8|
|B222-60FGFST<br>B222-60FGFWTST|Pullout disconnect with GFCI<br>Pullout disconnect with weather-resistant/<br>tamper-resistant rated GFCI|60|3<br>10|H or R|13|7-1/2|4-3/4|
|Non-fused disconnects||||||||
|B222-60NF|Pullout disconnect||||8-3/4|5-3/8|2-7/8|
|B222-60NFGFWTST|Pullout disconnect with weather-resistant/<br>tamper-resistant rated GFCI|60|3<br>10|*|11-3/4|6-1/2|4-1/2|
|B222-60NFNA|Disconnect switch||—||8-3/4|5-3/8|3-5/8|
* Upstream overcurrent protective device (OPCD) not to exceed 60 A.
10kA Short-Circuit Current Rating when protected by max fuse or circuit breaker size of 60 A. For a 30 and 60 amp pullout replacement handle, order catalog number 96-3258-4.
## Recommended Bussmann series fuses
|Fuse class|Fuse class|Catalogsymbol|Operation|Available amps|Data sheet no.|
|---|---|---|---|---|---|
||H|NON-(amp)|One time,generalpurpose|Upto 60|1030|
|||FRN-R-(amp) (non-indicating)|||1019|
||R|FRN-R-(amp)ID (indicating)<br>LPN-RK-(amp)SP (non-indicating)|Dual element, time-delay|Up to 60|1019<br>1003|
|||LPN-RK-(amp)SPI (indicating)||35 to 60|1003|
Data sheet no. 1143
Eaton.com/bussmannseries
12-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
## Contents
|Description|Section<br>page|||
|---|---|---|---|
|Selecting Type 1 SPDs|2-3|||
|Type 1 SPDs||||
|SurgePOD PRO Type 1, NEMA 4X|4-5|||
|BSPA, Type 1 and 2, NEMA 4X|6-9|||
|BSPD high capacity Type 1 and 2, NEMA 1 and 4X|10-14|||
|UL DIN-Rail high SCCR Type 1 SPDs||||
|1-pole, BSPM_S2G|15-16|||
|2-pole, BSPM_S3G|17-18|||
|3-pole, BSPM_WYG/DLG|19-20|||
|4-pole, BSPM_WYNG/HLG|21-22|||
|UL DIN-Rail power and control voltage Type 4 SPDs||||
|1-pole, Type 4 power BSPM_LV|23-24|||
|2-pole, Type 4 voltage BSPH2A_LV|25-26|||
|UL 497B DIN-Rail data signal SPDs||||
|RJ45/Ethernet<br>Universal 4 wire|27<br>28-29|Surge protective|devices|
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-1
**13 — Surge protective devices** ~~7~~
## Selecting a Type 1 SPD
Electrical systems and connections
Step 1: Review the following system diagrams that show the SPD connection points for the Bussmann series SPD models that may be applied.
Step 2: Locate the system diagram that matches your application, note the applicable SPD model numbers and then proceed to the product pages for their details.
Understanding the following will help assure that the correct surge protective device is specified:
- Typical North American electrical systems include single-phase, split-phase, Delta and Wye.
- Selecting the wrong SPD generally arises from misunderstanding the nominal system voltage, ground and neutral connections.
**==> picture [180 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
BSPD high capacity BSPA<br>**----- End of picture text -----**<br>
- General convention has it that a “ground” wire is not counted as a wire in the system description (e.g., 3 wire, 4 wire, etc.), but it is counted as a connection point if the SPD has a ground wire.
- Selecting a voltage rating for Wye systems must be based upon its nominal system voltage rating and not on the leg-to-leg voltages.
**==> picture [54 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
SurgePOD PRO<br>**----- End of picture text -----**<br>
- Bonded N-G configurations do not require protection at the service entrance transformer, but protection is suggested in downstream bonded N-G systems if the length of conductor making the bond is greater than 10 feet (3m).
Two wire single-phase - 2 connection points
Application: Sub-panel or feeder panel
Volts: 120, 240 (L-N)
Note: Must be installed within 10 feet (3m) of a bonded neutral ground connection per IEEE C62.41-1991.
Three wire split-phase/twopole - 3 connection points
Three wire split-phase/twopole - 3 connection points
Application: Sub-panel or feeder panel
Application: Service entrance panel Volts: 120, 240 (L-N)
Volts: 120, 240 (L-N), 240, 480 (L1-L2)
Note: Installation for where the SPD is greater than 10 feet (3m) Note: Installation at or less from a bonded neutral-ground than 10 feet (3m) from the connection. transformer and within 10 feet (3m) of a bonded-neutral ground connection.
Three wire split-phase/twopole plus ground - 4 connection points
Application: Service entrance equipment
Volts: 120, 240 (L-N), 240 (L1-L2)
Note: Installation where greater than 10 feet (3m) of a bonded-neutral ground connection.
**==> picture [492 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
G L1 N L2 Dedicated two-pole<br>Dedicated one-pole circuit breaker, or one-polefusible switch Dedicated one-pole circuit breaker, or one-polefusible switch common trip circuit breaker, or two-pole fusible switch Dedicated two-pole common trip circuit breaker, or two-pole fusible switch<br>Black<br>Black Black Black<br>Black<br>Black<br>White White<br>White<br>White Green L1 L2 Green<br>L1 L1 L1 L2<br>G N<br>G N G N<br>G N<br>**----- End of picture text -----**<br>
## SPD catalog numbers:
## • BSPA
- Specify from build-a-code catalog number system
- SurgePOD™ PRO
- SPP40SP1120SN
## SPD catalog numbers:
## • BSPA
- Specify from build-a-code catalog number system
## SPD catalog numbers:
- BSPA
- Specify from build-a-code catalog number system
- SurgePOD PRO
- SPP40SP2240PN
## SPD catalog numbers:
- BSPA
- Specify from build-a-code catalog number system
Eaton.com/bussmannseries
13-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
Four wire Wye plus ground - 5 connection points
Three wire split-phase/twopole plus ground - 4 connection points
Three wire Wye plus ground - 4 connection points
Four wire Wye plus ground - 5 connection points
Application: Service entrance equipment
Application: Sub-panel or feeder panel
Application: Sub-panel or feeder panel
Application: Sub-panel or feeder panel
Volts: 120, 127, 277, 347 (L-N), 208, 220, 480, 600 (L-L)
Volts: 208, 480, 600 (L-L)
Volts: 120, 127, 277, 347 (L-N), 208, 220, 480, 600 (L-L)
Volts: 120, 240 (L-N), 240 (L1-L2)
Note: A common MCC configuration for pumping and Note: Common system water/waste water treatment. configuration with Neutral pulled into facility and bonded to ground.
Note: Common system configuration with Neutral pulled into facility and bonded to ground.
Note: For installation greater than 10 feet (3m) of a bondedneutral ground connection.
**==> picture [243 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 N L2 L3<br>Dedicated three-pole<br>common trip circuit<br>breaker, or three-pole<br>fusible switch<br>Black<br>Dedicated three-pole Black<br>common trip circuit<br>breaker, or three-pole Black<br>fusible switch<br>White<br>Black Green<br>Black L1 L2 L3<br>Black<br>White G N<br>Green<br>L1 L2 L3<br>G N SPD catalog numbers:<br>**----- End of picture text -----**<br>
**==> picture [243 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 N L2 Dedicated two-pole<br>common trip<br>circuit breaker, or Dedicated three-pole<br>two-pole common trip circuit<br>fusible switch breaker, or three-pole<br>fusible switch<br>Black<br>Black<br>Black<br>Black<br>White Black<br>Green<br>L1 L2 Green<br>L1 L2 L3<br>G N G<br>**----- End of picture text -----**<br>
## SPD catalog numbers:
## SPD catalog numbers:
- BSPA
## • BSPA
## • BSPA
- Specify from build-a-code catalog number system
## SPD catalog numbers:
- Specify from build-a-code catalog number system
- Specify from build-a-code catalog number system
- BSPA
- BSPD
- Specify from build-a-code catalog number system
- SurgePOD PRO
- Specify from build-a-code catalog number system
- SPP40SP3208WYG
- BSPD
- SPP4SP3480WYG
- Specify from build-a-code catalog number system
Three wire Delta plus ground - 4 connection points
Application: Service entrance equipment, sub-panel or feeder panel
Volts: 240, 480, 600 (L-L)
**==> picture [106 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dedicated three-pole<br>common trip circuit<br>breaker, or three-pole<br>fusible switch<br>Black<br>Black<br>Black<br>Green<br>L1 L2 L3<br>G<br>**----- End of picture text -----**<br>
SPD catalog numbers:
## • BSPA
- Specify from build-a-code catalog number system
## • BSPD
- Specify from build-a-code catalog number system
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-3
**13 — Surge protective devices** ara i
## SurgePOD™ PRO for UL 1449 ~~4 ~~~[th] Edition Listed loadside and lineside protection
~~ee~~ Catalog no. SPP40SP1120SN SPP40SP3240DLG SPP40SP3208WYG SPP40SP2240PN SPP40SP3480DLG SPP40SP3480WYG SPP40SP3600WYG
The Bussmann series SurgePOD PRO is a Type 1 UL Listed 1449 ~~4~~[th] Edition surge protective device suitable for installation on both the loadside or lineside of the service entrance overcurrent protective device and is well suited for light commercial and residential applications.
See catalog number explanation below for details.
## Catalog number explanation
This is not a build-a-code for configuring an orderable catalog number. It's purpose is to show what portions of the catalog number denotes which specification.
SPP 40S Px xxx xxx
Available in popular voltage and system specific versions to match common residential and light commercial electrical system and equipment requirements. The SurgePOD PRO delivers superior surge protection using MOV thermal disconnect technology that **2011/65/EU** easyID™ LED Status Indicator eliminates the need for additional - overcurrent protection.
SPP = Product family
Surge rating
- 40 kA surge current capacity
Number of wires
- P1 = 1, P2 = 2, P3 = 3
System voltage (Vac)
Parallel connection to the electrical system permits the SurgePOD PRO SPD to be installed on any ampacity panel.
- 120, 208, 240, 480, 600
System type/wires and connection points
- Type 1 UL 1449 4[th] Edition Listed SPDs are easily selected and installed on the loadside or lineside of the service entrance overcurrent protective device
- SN = Single-phase 2 wire, 2 connection points
- PN = Split-phase 3 wire , 3 connection points
- Voltage specific models precisely match and protect electrical systems and equipment better than “one-size-fits-all” SPDs
- DLG = Three-phase Delta 3 wire + G, 4 connection points
- WYG = Three-phase Wye 3 wire + G, 4 connection points
- Thermal disconnect technology eliminates the need for additional fusing
- NEMA 4X enclosure for indoor or outdoor applications
## easyID™ LED status indicator
- easyID™ LED status indicator provides surge protection status at a glance
The easyID LED status indicator will illuminate when the unit is properly installed and the system or equipment being protected is energized. The following LED color/status indicates:
Dimensions — in
**==> picture [332 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
4-1/8”<br>Ø 1-1/16”<br>1-11/16”<br>3-3/8” 3-3/16”<br>4-1/16”<br>1-11/16”<br>felPoy “TELo,<br>7/8”<br>2-1/16” 2-1/16”<br>Mounting<br>**----- End of picture text -----**<br>
## GREEN LED = Good
The circuit is energized and protected.
## RED LED = Replace
The circuit is energized and unprotected. The unit needs replacing.
SurgePOD PRO is a panel mount device. It may also be mounted using a customer supplied bracket or directly onto a female threaded conduit fitting.
**==> picture [156 x 64] intentionally omitted <==**
**----- Start of picture text -----**<br>
For NEMA 4X installation, install appropriate customer<br>supplied gasket between SPD and enclosure wall.<br>Tighten locknut to<br>20.3 Lb-In (2.3N•m)<br>**----- End of picture text -----**<br>
## LED is Out / Unlit:
The circuit is most likely deenergized
The unit’s leads are disconnected
The unit is damaged
Authorized personnel should follow all prescribed lockout/tagout and safety procedures in troubleshooting the cause for the above conditions. Opening SurgePOD PRO enclosure will void the warranty.
Data sheet no. 10033
Eaton.com/bussmannseries
13-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
## SurgePOD PRO
**==> picture [536 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
Max. continuous operating AC<br>Catalog no. Nominal system voltage voltage (MCOV) (VC) System type Connection points<br>**----- End of picture text -----**<br>
|SPP40SP1120SN|120|150|Single-phase 2 wire|2|
|---|---|---|---|---|
|SPP40SP2240PN|120/240|150|Split-phase 3 wire|3|
|SPP40SP3240DLG|240|320|Three-phase Delta 3 wire + G|4|
|SPP40SP3480DLG|480|550|Three-phase Delta 3 wire + G|4|
|SPP40SP3208WYG|208|150|Three-phase Wye 3 wire + G|4|
|SPP40SP3480WYG|480|320|Three-phase Wye 3 wire + G|4|
|SPP40SP3600WYG*|600|420|Three-phase Wye 3 wire + G|4|
* Not CSA Certified.
**==> picture [536 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
Specifications (for all SurgePOD PRO units) Values<br>**----- End of picture text -----**<br>
|Short-Circuit Current Rating(SCCR)|200 kA|
|---|---|
|Nominal discharge current (8x20µs) (In)|10 kA|
|Surge current capacity(8x20µs) (Imax)|40 kA|
|Response time (ns) (tA)|<25ns|
|Frequency<br>Operatingstate/fault indication<br>Conductor length /gauge<br>Mounting<br>Enclosure / flammabilityratings|50/60 Hz<br>Bi-color LED -green (good) / red (replace)<br>18 inches, 10 AWG stranded tinned copper<br>Chase nipple / bracket*<br>NEMA 4X - UL 94-5VA|
|Degree ofprotection (installed state)|IP20 (finger-safe)|
|SPD install location|Indoor/outdoor|
|Circuit location|Lineside or loadside of service entrance overcurrentprotective device|
|Operatingtemperature|-40°C to +65°C|
|Maximum operatingaltitude|12,000FT|
|Agencyinformation|UL Listed, CSA Certified, RoHS compliant|
|Standard|UL Type 1 1449 4thEdition SPD|
|Warranty|Twoyears**|
* Customer-supplied bracket.
** See Limited Warranty Statement 3A1502 for details at Eaton.com/bussmannseries.
## Voltage protection ratings (VPR)
**==> picture [536 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal system Voltage Protection Ratings (VPR)<br>Catalog no. voltage MCOV (VC) L-N L-L L-G<br>**----- End of picture text -----**<br>
|SPP40SP1120SN|120|150|700|—|—|
|---|---|---|---|---|---|
|SPP40SP2240PN|120V/240|150|700|1200|—|
|SPP40SP3240DLG|240|320|—|2500|1200|
|SPP40SP3480DLG|480|550|—|3000|1800|
|SPP40SP3208WYG|208|150†|—|1200|700|
|SPP40SP3480WYG|480|320†|—|2500|1200|
|SPP40SP3600WYG|600|420†|—|2500|1500|
† SPD voltages are measured from Line-to-Neutral, or Line-to-Ground on systems where there is no neutral present. These units do not have a line-to-neutral, so the line-to-ground voltage is 120 V for the 208 V Wye L-G and 277 V for the 480 V L-G, making the normal voltage applied to the unit less than the MCOV values listed in the table.
Data sheet no. 10033
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-5
**13 — Surge protective devices**
## BSPA NEMA 4X Type 1 and 2
## Catalog number system
**==> picture [27 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
The Bussmann series BSPA surge protective devices are UL 1449 4[th] Edition surge protectors. Application of BSPA units throughout a facility will help ensure that equipment is protected from damaging surges.
The BSPA compact NEMA 4X enclosure allows for installation external to an electrical assembly in a variety of environments.
BSPA units are available in all common voltage and system configurations, and in a variety of peak surge current capacity ratings from 50 through 200 kA per phase. Several feature package options (filtering, audible alarm and Form C contacts) extend application flexibility along with a range of configurable options suitable for most commercial and light industrial applications covering service entrances, distribution panelboards and point-of-use applications.
## Agency information
- UL 1449 4[th] Edition Type 1 and Type 2
- UL 1283 6[th] Edition
- Canadian Standards Association (CSAT) Type 1 and Type 2
- CSA C22.2 No. 269.1-14 for Type 1 SPD, CSA C22.2 No. 269.2-13 for Type 2 SPD, CSA C22.2 No. 8-13 for EMI filter
- RoHS compliant
## Features
The catalog numbering system permits specifying any combination to meet requirements.
BSPA 200 208Y 8 P BSPA = Product family Surge rating per phase ~~|~~ • 050 = 50 kA per phase
- 100 = 100 kA per phase
- 150 = 150 kA per phase
- 200 = 200 kA per phase
Voltage/system code
- 120N = 120 V single-phase (2W +G)
- 240N = 240 V single-phase (2W +G)
- 240S = 120/240 V split-phase (3W +G)
- 240D = 240 V Delta (3W + G)
- 480D = 480 V Delta (3W + G)
- 600D = 600 V Delta (3W + G)
- 208Y = 120/208 V Wye (4W + G)
- 415Y = 240/415 V Wye (4W + G)
- 480Y = 277/480 V Wye (4W + G)
- 600Y = 347/600 V Wye (4W + G)
Options
- 1 = No options (standard configuration), Type 1
- 4 = Form C relay, Type 1
- Thermally-protected metal oxide varistor (MOV) technology
- Tri-colored LED status indicators display continuous self-diagnostic testing, including neutral-ground mode
- 20 kA nominal discharge current (In) rating (maximum rating in the UL 1449 4[th] Edition standard)
- 50 through 200 kA per phase peak surge current capacity ratings
- 5 = Audible alarm and Form C relay, Type 1
- 7 = EMI filtering and Form C relay, Type 2
- 8 = EMI filtering, audible alarm and Form C relay, Type 2
- NEMA enclosure
- P = NEMA 4X
- Configure to order with five feature/option combinations
- Corrosion-resistant NEMA 4X enclosure with detachable mounting feet
- 200 kA short-circuit current rating (SCCR)
- Factory wired with 36-inch 10 AWG leads
- Optional Form C contact relay for integration into remote monitoring systems*
- Optional EMI/RFI filtering form improved power quality*
- Optional audible alarm*
- No user-serviceable parts or items requiring periodic maintenance
- Ten-year warranty
- See catalog number system for availability.
BSPA wire port and conductors
BSPA with mounting feet
Data sheet no. 10661
Eaton.com/bussmannseries
13-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
## BSPA configurations
The BSPA allows for selecting along with the standard features the audible alarm, Form C relay contacts and EMI/RFI filtering options shown in table 1.
Configurable features
|Configurable features||
|---|---|
|Feature<br>Surge protection using thermally protected<br>MOV technology|Standard<br>Options<br>•|
|Tri-colored LED protection status indicators for<br>eachphase|•|
|Tri-colored LED protection status indicators for<br>the neutral-groundprotection mode|•|
|Audible alarm<br>Form C relaycontact<br>EMI/RFI filtering, for up to 40 dB of noise atten-<br>uation from 10 kHz to 100 MHz*|•<br>•<br>•|
* Available on Type 2 SPD units only.
## Tri-colored LED status indicators
These LED indicators show continuous self-diagnostic testing, including neutral-ground mode and display:
- Green—Fully protected
- Yellow—Loss of neutral-to-ground protection
- Red—Loss of protection
LED protection status indicators showing full protection and phase faults
## Enclosure ratings, options, dimensions and weights
The BSPA NEMA 4X enclosure is supplied with mounting feet to facilitate installation in a variety of applications. There are two enclosure sizes, P1 and P2, dependent on the voltage code and surge rating.
## Available optional equipment
Voltage protection ratings (VPRs) per ANSI/UL 1449 4[th] Edition
|Voltage<br>code|L–N|Protection mode<br>L–G<br>N–G|Protection mode<br>L–G<br>N–G|L–L|
|---|---|---|---|---|
|50 kA unit VPR|||||
|120N|700|1200|700|—|
|240N|1200|2000|1500|—|
|240S|700|1200|700|1200|
|208Y|700|1200|700|1200|
|415Y|1200|2000|1500|2000|
|480Y|1200|2000|1500|2000|
|600Y|1500|1500|1500|2500|
|240D|—|1000|—|1000|
|480D|—|2000|—|2500|
|600D|—|2500|—|2500|
|100 kA unit VPR|||||
|120N<br>240N<br>240S<br>208Y<br>415Y|600<br>1200<br>600<br>600<br>1200|600<br>1200<br>600<br>600<br>1200|600<br>1200<br>600<br>600<br>1200|—<br>—<br>1000<br>1000<br>2000|
|480Y|1200|1200|1200|2000|
|600Y<br>240D|1500<br>—|1500<br>1000|1500<br>—|2500<br>1000|
|480D|—|2000|—|2500|
|600D|—|2500|—|2500|
|150-200 kA unit VPR<br>120N<br>700<br>240N<br>1000||700<br>1200|700<br>1000|—<br>—|
|240S|700|700|700|1200|
|208Y|700|700|700|1200|
|415Y|1200|1200|1200|2000|
|480Y|1200|1200|1200|2000|
|600Y|1500|1500|1500|2500|
|240D|—|1000|—|1000|
|480D|—|1800|—|2000|
|600D|—|2500|—|2500|
|Available option|Catalogno.|
|---|---|
|Flush mountplate for P1 enclosure|BSPA-FLUSHPLT1|
|Flush mountplate for P2 enclosure|BSPA-FLUSHPLT2|
BSPA voltage configurations per enclosure size*
|P1 enclosure|P2 enclosure|
|---|---|
|Voltage code<br>kA|Voltage code<br>kA|
|120N/240N<br>50–200|240S<br>120–200<br>208Y/415Y/480Y/600Y<br>240D/480D|
|240S<br>50-100<br>208Y/415Y/480Y/600Y<br>240D/480D||
||600D<br>50–200|
* See catalog number system for voltage code details.
Data sheet no. 10661
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-7
**13 — Surge protective devices**
## BSPA specifications
**==> picture [537 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
Description Value<br>**----- End of picture text -----**<br>
|Leads|Length|36”|
|---|---|---|
||Size|10 AWG stranded copper|
|Mounting||Chase nipple/panel (with mountingfeet)|
|Peak surge current capacityratings available||50, 100, 150, 200 kAperphase|
|Nominal discharge current (In)||20 kA|
|Short-circuit current rating(SCCR)||200 kA|
|Single-phase voltages available (2W + G)||120, 240|
|Split-phase voltages available (3W +G)||120/240|
|Three-phase Wye system voltages available (4W + G)||120/208, 240/415, 277/480, 347/600|
|Three-phase Delta system voltages available (3W + G)||240, 480, 600|
|Inputpower frequency||50/60 Hz|
|Protection modes|Single–phase|L–N, N–G, L–G|
||Split–phase|L–N, N–G, L–G, L–L|
||Wye|L–N, N–G, L–G, L–L|
||Delta|L–G, L–L|
|Maximum continuous operating voltage (MCOV):|Voltage code||
||120N|150 L–N, 150 L–G, 150 N–G|
||240N|320 L–N, 320 L–G, 320 N–G|
||240S, 208Y|150 L–N, 150 L–G, 150 N–G, 300 L–L|
||415Y, 480Y|320 L–N, 320 L–G, 320 N–G, 640 L–L|
||600Y|420 L–N, 420 L–G, 420 N–G, 840 L–L|
||240D|320 L–G, 300 L–L|
||480D|550 L–G, 640 L–L|
||600D|840 L–G, 840 L–L|
|Ports||1|
|Operatingand storage temperature||–40°F to +140°F (–40°C to +60°C)|
|Operatinghumidity||5% through 95%, non-condensing|
|Operatingaltitude||Upto 2000 m (6561 ft)|
|Agency information||UL 1449 4thedition, UL 1283 6th edition, CSA C22.2 No. 269.1-14 for<br>Type 1 SPD, CSA C22.2 No. 269.2-13 for Type 2 SPD, CSA C22.2 No.<br>8-13 for EMI filter|
|Durability/repetitive strike test||Passed 12,000 strikes to ANSI/IEEE C62.41 (20 kV, 10 kA) Category C<br>waveform|
|SPD type||UL 1449 4thedition and CSA Type 1 and Type 2 SPD (dependent on<br>feature options)|
|Enclosure dimensions and weights||Refer to Figure 1 and Figure 3 for enclosure dimensions and weights|
|Enclosure rating||NEMA 4X enclosure*|
|Form C relaycontact ratings||2 A at 30 Vdc or 250 Vac|
|Form C relay contact logic||Power ON, normal state—NO contact = open, NC contact = closed|
|||Power OFF or fault state—NO contact = closed, NC contact = open|
|EMI/RFI filteringattenuation||Upto 40 dB from 10 kHz to 100 MHz|
|RoHS compliant||Yes|
|Warranty||Tenyears standard|
* Mounting feet required to achieve NEMA 4X rating.
Data sheet no. 10661
Eaton.com/bussmannseries
13-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
Dimensions — in (mm)
**==> picture [535 x 252] intentionally omitted <==**
**----- Start of picture text -----**<br>
6.00 8.50<br>3.75 (152.3) (215.9)<br>(95.3) Lid 3.75 Lid<br>36-inch (95.3)<br>long wires 36-inch<br>1.12 (28.5) long wires<br>Mounting feet(included) 5.50 (139.6)Lid 4x #8 [m 4] Mounting feet(included) (60.4)2.38<br>6.62 (168.1) Flathead screw<br>7.50 (190.5) Lid<br>(not included) 4x #8 (m4)<br>Overall base 8.62 (219.0) Flathead screw<br>including 7.56 (192.0) (not included)<br>stabilization ribs overall base including<br>0.75 (19.1) 5.56 (141.2) 0.75 (19.1) stabilization ribs<br>Locknut Locknut<br>external thread3/4-14 NPS (81.0)3.19 external thread3/4-14 NPS (81.1)3.19<br>9.13 (232.0)<br>7.13 (181.2) 1.00 (25.4)<br>1.00 (25.4) 0.16 (4.1)<br>0.16 (4.1) mounting feet<br>Mounting feet (included)<br>(included)<br>**----- End of picture text -----**<br>
**==> picture [26 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
devices<br>Surge protective<br>**----- End of picture text -----**<br>
P1 enclosure, NEMA 4X with mounting feet dimensions, weight = 2.5 lb
P2 enclosure, NEMA 4X with mounting feet dimensions, weight = 4 lb
**==> picture [262 x 197] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.80<br>(20.3)<br>1.51<br>(38.4)<br>7.75<br>(196.9)<br>4.17 5.98<br>(105.9) (151.2)<br>9.00<br>(228.6)<br>1.51 4X Ø<br>(38.4) 0.223<br>0.0747 THK 5.48 (139.2)<br>7.25 (184.2)<br>8.50 (215.9)<br>**----- End of picture text -----**<br>
**==> picture [263 x 192] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.80<br>(20.3)<br>1.51<br>(38.4)<br>10.25<br>(260.4)<br>6.67<br>8.48<br>(169.4)<br>(215.4)<br>11.50<br>(292.1)<br>1.51 4X Ø<br>(38.4) 0.223<br>0.0747 THK 7.48 (190.0)<br>9.25 (235.0)<br>10.50 (266.7)<br>**----- End of picture text -----**<br>
Optional flush mount plate for P1 enclosure (catalog number BSPA-FLUSHPLT1)
Optional flush mount plate for P2 enclosure (catalog number BSPA-FLUSHPLT2)
Data sheet no. 10661
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-9
**13 — Surge protective devices**
## BSPD high capacity Type 1 and 2
BSPD Surge Protective Devices (SPDs) are UL Listed 1449 4[th] Edition Type 1 or UL Recognized 1283 5[th] Edition Type 2 surge protectors, depending on the configuration. The BSPD is available for installation external to an electrical enclosure or panelboard. Application of BSPD units throughout a facility will help ensure that equipment is protected.
**==> picture [27 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
NEMA 1 steel enclosure 120 kA and 200 kA maximum surge current capacity
BSPD units are available for common Delta and Wye voltage systems in a variety of surge current capacity ratings from 120 kA through 400 kA. Available in three configurations, the BSPD’s configurations and options make it easy to specify units for many electrical applications; including service entrances, distribution switchboards, panelboards and point-of-use.
NEMA 1 steel enclosure 300 kA and 400 kA maximum surge current
- Basic, Standard and capacity Standard with Surge Counter configurations UL Listed 1449 ~~4~~[th] Edition, Guide VZCA, File E316410, CSA Certified Notice 516 File 243397
- Standard and Standard with Surge Counter configurations are also UL Recognized 1283 ~~5~~[th] Edition, Guide VZCA2, File E316410, CSA Component Acceptance Std. C22.2
NEMA 4X 304 Stainless Steel enclosure, all surge current capacities
- RoHS compliant
- 20 kA nominal discharge current (In) rating (maximum rating assigned by UL)
- 120 kA through 400 kA per phase surge current capacity (Imax) ratings
- 200 kA Short-Circuit Current Rating (SCCR)
- Two color LED status indicators for each phase on Delta and Wye units, plus N-G on Wye units
- 10-Year warranty
## Configurations
The BSPD provides users with the option of selecting between three configurations:
- Basic (Type 1)
## Catalog number system
The catalog numbering system permits specifying any combination to meet requirements.
BSPD 200 480D 2 K
BSPD = Product family
Surge rating per phase
- 120 = 120 kA
- 200 = 200 kA
- 300 = 300 kA
- 400 = 400 kA
Voltage/system code
- 208Y = 120/208 Wye (4W + G)
- 480Y = 277/480 Wye (4W + G)
- 600Y = 347/600 Wye (4W + G)
- 240D = 240 Delta (3W + G)
- 480D = 480 Delta (3W + G)
- 600D = 600 Delta (3W + G)
Configurations
- 1 = Basic
- Green and red LEDs per phase to indicate protection status.
- Green and red LEDs on Wye units to indicate protection status of the neutral-to-ground mode
- 2 = Standard
- Green and red LEDs per phase to indicate protection status
- Green and red LEDs on Wye units to indicate protection status of the neutral-to-ground mode
- Audible alarm with silence button
- Form C contact relay
- EMI/RFI filtering providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz
- 3 = Standard With Surge Counter
- Green and red LEDs per phase to indicate protection status
- Green and red LEDs on Wye units to indicate protection status of the neutral-to-ground mode
- Audible alarm with silence button
- Form C contact relay
- EMI/RFI filtering providing up to 50 dB of noise attenuation from 10 kHz to 100 MHz
- Surge counter with reset button
- Standard with Form C contact and EMI/RFI filter (Type 2)
NEMA enclosures
- K = NEMA 1
- Standard with Surge Counter (Type 2)
- P = NEMA 4X
The appropriate configuration can be specified from the catalog number system based on the application’s requirements or specifications.
Data sheet no. 10209
Eaton.com/bussmannseries
13-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
## BSPD configurations
|Features|Basic<br>(Type 1)|Configuration<br>Standard<br>(Type 2)<br>Standard with<br>Surge Counter<br>(Type 2)|Configuration<br>Standard<br>(Type 2)<br>Standard with<br>Surge Counter<br>(Type 2)|
|---|---|---|---|
|Two color LEDprotection status indicators for eachphase|X|X|X|
|Two color LEDprotection status indicators for the neutral-groundprotection mode (Wye systems only)|X|X|X|
|Audible alarm with silence button||X|X|
|Form C contact relay||X|X|
|EMI/RFI filtering,providingupto 50 dB of noise attenuation from 10 kHz to 100 MHz||X|X|
|Surge counter with reset button|||X|
Dimensions — in (mm)
**==> picture [262 x 209] intentionally omitted <==**
**----- Start of picture text -----**<br>
7.28<br>(184.9)<br>1.00<br>5.27 (25.4)<br>(133.9)<br>12.05 10.48 11.25<br>(306.1) (266.2) (285.8)<br>0.68<br>5.24 (17.3)<br>(133.1)<br>Ø0.20<br>(Ø5.1)<br>2.00<br>0.78 (50.8) 7.47 0.40<br>(19.8) 3.48 (189.7) (10.2)<br>(88.4)<br>4.41<br>(112.0)<br>**----- End of picture text -----**<br>
120 kA and 200 kA Units/NEMA 1
**==> picture [210 x 123] intentionally omitted <==**
**==> picture [121 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B<br>120-200kA 2.60 (66.0) 5.39 (137.0)<br>250-400kA 4.10 (104.1) 7.68 (195.0)<br>**----- End of picture text -----**<br>
120 kA to 400 kA Units/NEMA 4X
**==> picture [262 x 186] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.00<br>5.47 (25.4)<br>(138.9)<br>12.05<br>(306.1) 10.48 11.25<br>(266.2)<br>(285.8)<br>0.67<br>5.24<br>(17.0)<br>(133.1)<br>2.00 Ø0.20<br>0.78 (50.8) (Ø5.1) 7.47 0.40<br>5.76 (189.7)<br>(19.8) (10.2)<br>(146.3)<br>6.69<br>(169.9)<br>300 kA and 400 kA Units/NEMA 1<br>**----- End of picture text -----**<br>
Form C Contact relay wire color codes
Common Blue/white NO (normally open) Red/white NC (normally closed) Orange/white
Data sheet no. 10209
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-11
**13 — Surge protective devices**
## BSPD specifications
**==> picture [537 x 577] intentionally omitted <==**
**----- Start of picture text -----**<br>
Description Values<br>Available system voltages<br>Three-phase Wye 120/208, 277/480 and 347/600<br>Three-phase Delta 240, 480 and 600<br>Input power frequency 50/60 Hz<br>Maximum Continuous Operating Voltage (MCOV)<br>208Y, and 240D voltage/system codes 150 L-N,150 L-G, 150 N-G, 300 L-L<br>480Y Voltage/system code 320 L-N, 320 L-G, 320 N-G, 640 L-L<br>600Y Voltage/system code 420 L-N, 420 L-G, 420 N-G, 840 L-L<br>480D Voltage/system code 640 L-G, 640 L-L<br>600D Voltage/system code 840 L-G, 840 L-L<br>Short-Circuit Current Rating (SCCR) 200 kA<br>Nominal discharge current (In) 20 kA<br>Surge current capacity per phase (Imax) 120 kA, 200 kA, 300 kA and 400 kA ratings available<br>SPD Types<br>Type 1 Basic configuration, can also be used in Type 2 applications<br>Type 2 Standard and Standard With Surge Counter configurations<br>Enclosure types NEMA 1<br>NEMA 4X 304 stainless steel<br>Ports 1<br>SPD conductor length/gauge 48” (1.22m) 10 AWG Stranded copper<br>Form C contact relay (Standard and Standard With Surge Counter configurations only)<br>Contact ratings 150 Vac or 125 Vdc, 1A maximum<br>Lead length/gauge 48 inches (1.22m) / 14 AWG<br>Power ON, normal state; N.O. contact = OPEN, N.C. contact = CLOSED<br>Contact logic<br>Power OFF, fault state; N.O. contact = CLOSED, N.C. contact = OPEN<br>Power consumption<br>0.5 W — 208Y and 240D voltage/system codes<br>Basic configuration 1.1 W — 480Y and 480D voltage/system codes<br>1.3 W — 600Y and 600D voltage/system codes<br>0.6 W — 208Y and 240D voltage/system codes<br>Standard and<br>Standard with Surge Counter configurations 1.7 W — 480Y, and 480D voltage/system codes<br>2.1 W — 600Y and 600D voltage/system codes<br>Protection modes<br>Three-phase Delta L-G, L-L<br>Three-phase Wye L-N, L-G, N-G, L-L<br>Operating temperature / humidity -40 to +50°C (-40 to +122°F) / 5% to 95%, non-condensing<br>Operating altitude - ft (m) 16,000 (5000)<br>EMI/RFI filtering attenuation Up to 50 dB from 10 kHz to 100 MHz (Standard and Standard With Surge Counter configurations)<br>Weight - lbs (kg)<br>120-200 kA - 6.8 (3.1)<br>NEMA 1<br>300- 400 kA -13.5 (6.1)<br>120-200 kA - 14.6 (6.6)<br>NEMA 4X<br>300-400 kA - 21.0 (9.5)<br>Agency information<br>Basic, Standard and Standard with Surge Counter UL Listed 1449 4 [th] Edition File E316410 Guide VZCA, CSA Certified Notice 516 File 243397<br>configurations<br>Standard and UL Recognized 1283 5 [th] Edition File E316410 Guide VZCA2, CSA Component Acceptance Std. C22.2 No.<br>Standard with Surge Counter configurations 8-M1986, File 243397<br>RoHS compliant Yes<br>Seismic withstand capability Meets or exceeds the requirements specific to I.B.C. 2006, C.B.C. 2007 and U.B.C. Zone 4<br>Warranty 10 Years (see warranty statement 3A1502 for details at Eaton.com/bussmannseries)<br>**----- End of picture text -----**<br>
Data sheet no. 10209
Eaton.com/bussmannseries
13-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
## Voltage protection ratings
## ANSI/UL 1449 4[th] Edition voltage protection ratings
Voltage Protection Rating (VPR) data for all units is included in the following tables, The data varies based upon the configuration and NEMA enclosure. VPR values for the Basic configurations are on the left-hand side of the page. Tables on the right-hand side contain VPR values for the Standard or Standard with Surge Counter configurations.
## NEMA 1: Basic
Catalog numbers ending with 1K.
## 120-200 kA
**==> picture [264 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection mode<br>Voltage/system code L-N L-G N-G L-L<br>**----- End of picture text -----**<br>
|208Y|700|700|700|1200|
|---|---|---|---|---|
|480Y|1200|1200|1200|2000|
|600Y|1500|1500|1500|2500|
|240D<br>480D|—<br>—|1000<br>2000|—<br>—|1000<br>2500|
|600D|—|2500|—|2500|
## 300 kA
**==> picture [264 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection mode<br>Voltage/system code L-N L-G N-G L-L<br>**----- End of picture text -----**<br>
|208Y|700|700|700|1000|
|---|---|---|---|---|
|480Y|1200|1200|1200|1800|
|600Y|1500|1500|1500|2500|
|240D|—|1000|—|1000|
|480D|—|1800|—|2000|
|600D|—|2500|—|2500|
## 400 kA
**==> picture [264 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection mode<br>Voltage/system code L-N L-G N-G L-L<br>**----- End of picture text -----**<br>
|208Y|700|700|700|1000|
|---|---|---|---|---|
|480Y|1200|1200|1200|1800|
|600Y|1500|1500|1500|2500|
|240D|—|1000|—|1000|
|480D|—|1800|—|2000|
|600D|—|2500|—|2500|
## NEMA 1: Standard or Standard w/ Surge Counter
Catalog numbers ending with 2K or 3K.
120-200 kA
**==> picture [263 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection mode<br>Voltage/system code L-N L-G N-G L-L<br>**----- End of picture text -----**<br>
|208Y|600|800|600|1000|
|---|---|---|---|---|
|480Y|1200|1200|1200|1800|
|600Y|1500|1500|1500|2500|
|240D<br>480D|—<br>—|1000<br>2500|—<br>—|1000<br>2500|
|600D|—|2500|—|2500|
## 300 kA
**==> picture [263 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection mode<br>Voltage/system code L-N L-G N-G L-L<br>**----- End of picture text -----**<br>
|208Y|600|700|600|1000|
|---|---|---|---|---|
|480Y|1000|1200|1000|1800|
|600Y|1500|1500|1500|2500|
|240D|—|1000|—|1000|
|480D|—|1800|—|2000|
|600D|—|2500|—|2500|
## 400 kA
|Voltage/system code|Protection mode|
|---|---|
||L-N<br>L-G<br>N-G<br>L-L|
|208Y|600<br>700<br>600<br>1000|
|480Y|1000<br>1200<br>1000<br>1800|
|600Y|1500<br>1500<br>1500<br>2500|
|240D|—<br>1000<br>—<br>1000|
|480D|—<br>1800<br>—<br>2000|
|600D|—<br>2500<br>—<br>2500|
Data sheet no. 10209
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-13
**13 — Surge protective devices**
## Voltage protection ratings continued
## NEMA 4X: Basic
Catalog numbers ending with 1P.
## 120–200 kA
**==> picture [263 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection mode<br>Voltage/system code L-N L-G N-G L-L<br>**----- End of picture text -----**<br>
|208Y|700|800|700|1200|
|---|---|---|---|---|
|480Y|1200|1200|1000|2000|
|600Y|1500|1500|1500|2500|
|240D|—|1000|—|1000|
|480D|—|2000|—|2500|
|600D|—|2500|—|2500|
## 300 kA
**==> picture [263 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection mode<br>Voltage/system code L-N L-G N-G L-L<br>**----- End of picture text -----**<br>
|208Y|700|800|700|1200|
|---|---|---|---|---|
|480Y|1200|1200|1200|2000|
|600Y|1500|1500|1500|2500|
|240D|—|1000|—|1000|
|480D|—|1800|—|2000|
|600D|—|2500|—|2500|
## 400 kA
**==> picture [263 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection mode<br>Voltage/system code L-N L-G N-G L-L<br>**----- End of picture text -----**<br>
|208Y|700|800|700|1200|
|---|---|---|---|---|
|480Y|1200|1200|1200|2000|
|600Y|1500|1500|1500|2500|
|240D|—|1000|—|1000|
|480D|—|1800|—|2000|
|600D|—|2500|—|2500|
## NEMA 4X: Standard or Standard w/ Surge Counter
Catalog numbers ending with 2P or 3P.
## 120–200 kA
**==> picture [263 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection mode<br>Voltage/system code L-N L-G N-G L-L<br>**----- End of picture text -----**<br>
|208Y|900|900|700|1500|
|---|---|---|---|---|
|480Y|1200|1200|1000|2500|
|600Y|1500|1500|1500|2500|
|240D|—|1000|—|1000|
|480D|—|2500|—|2500|
|600D|—|2500|—|2500|
## 300 kA
**==> picture [263 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protection mode<br>Voltage/system code L-N L-G N-G L-L<br>**----- End of picture text -----**<br>
|208Y|800|900|700|1500|
|---|---|---|---|---|
|480Y|1200|1200|1000|2000|
|600Y|1500|1500|1500|2500|
|240D|—|1000|—|1000|
|480D|—|2000|—|2000|
|600D|—|2500|—|2500|
## 400 kA
|Voltage/system code|Protection mode|
|---|---|
||L-N<br>L-G<br>N-G<br>L-L|
|208Y|800<br>900<br>700<br>1500|
|480Y|1200<br>1200<br>1000<br>2000|
|600Y|1500<br>1500<br>1500<br>2500|
|240D|—<br>1000<br>—<br>1000|
|480D|—<br>2000<br>—<br>2000|
|600D|—<br>2500<br>—<br>2500|
Data sheet no. 10209
Eaton.com/bussmannseries
13-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
1-Pole, UL Type 1 DIN-Rail high SCCR surge protective devices
Dimensions — mm
**==> picture [60 x 64] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>&<br>**----- End of picture text -----**<br>
## Catalog symbol:
- BSPMA1_S2GR
## Description:
The Bussmann™ series one-pole DIN-Rail UL Listed Type 1 surge protective devices feature a high 200 kA SCCR. Replaceable arrestor modules are mechanically coded with the base to ensure against installing an incorrect replacement. The unique module locking system fixes the module to the base, and allows it to be easily replaced without tools by simply depressing the release buttons.
## Standard local visual status indication:
The module’s visual indicator shows the protective status at a glance: green = good, red = replace.
## Remote contact signaling:
The standard three-pole terminal remote Form C contact signaling relay has a floating changeover contact for use as a break or make contact, according to circuit concept.
## Ratings:
- System volts/types
- 120 Vac single-phase
- 240 Vac single-phase
- Short-circuit Current Rating (SCCR) 200 kA
## Agency information:
- UL Listed open Type 1, ANSI/ UL 1449 4[th] Edition, Guide VZCA, VZCA7
- CSA Type 4-1 Component Assembly, C22.2 No. 269.1-14, Class 2157-27
- RoHS compliant
## Mounting
- 35mm Din-Rail
## Warranty
- Five years
Data sheet no. 10771
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-15
## **13 — Surge protective devices**
|Specifications/orderinginformation|||||||
|---|---|---|---|---|---|---|
|System voltage/type|120 Vac single-phase|||240||Vac single-phase|
|Catalognumber|BSPMA1120S2GR|||BSPMA1240S2GR|||
|Replacement module catalognumber (qty.)|BPMA230UL (1)||||BPMA385UL (1)||
|SPD classper ANSI/UL 1449 4thEd.|||Open-Type 1 SPD||||
|SPD classper CSA - C22.2 No. 269.1-14|Type 4-1 Component Assembly||||||
|Nominal system voltage (UN) [L-N/L-G]|127 Vac|||||277 Vac|
|Nominalpower frequency|||50 / 60 Hz||||
|Max. continuous operatingvoltage AC (MCOV) [L-L]|230 Vac|||||385 Vac|
|Nominal discharge current (In) (8x20µs)|||20 kA||||
|Max. discharge current (Imax) (8/20)|||50 kA||||
|Voltage Protection Rating(VPR) [L-L]|700 Vpk|||||1200 Vpk|
|Short Circuit Current Rating(SCCR)|||200 kA||||
|Operatingtemperature range (TU) °F (°C)|||-31 to 185 (-35 to 85)||||
|Operatingstate / fault indication||Green =good ; Red = replace|||||
|Wire range (60/75°C Cu, solid/stranded)|||2-14 AWG (2.5-35 mm2)||||
|Terminal torque — lb-in (N•m)|||35-45 (4-5.1)||||
|Mounting||35|mm DIN-Railper EN 60715||||
|Enclosure material|||Thermoplastic, UL 94 V0||||
|Protection|||IP20 (finger-safe)||||
|Capacity|||1 module(s), DIN 43880||||
|Agencyinformation|UL Listed, Guide VZCA, VZCA7/CSA Component Acceptance Class 2157-27, RoHS||||||
|Weight - oz (g)|4.13 (117)|||||4.44 (126)|
|Contact signaling|||||||
|Signalingtype||Floating(dry), Form C (SPDT)|||||
|NEC Circuits|||NEC Class 2 circuits only||||
|SwitchingcapacityAC (DC)|250 V/5|A (250 V/0.1 A, 125 V/0.2 A,||75|V/0.5 A)||
|Wire range (60/75°C Cu, solid/stranded)||16-22 AWG (1.5-0.34mm2)|||||
|Terminal torque - lb-in (N•m)|||1.8 (0.2)||||
Typical installation/system application:
**==> picture [122 x 58] intentionally omitted <==**
**==> picture [14 x 43] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>N<br>**----- End of picture text -----**<br>
**==> picture [110 x 77] intentionally omitted <==**
**==> picture [13 x 65] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>N<br>L2<br>L3<br>**----- End of picture text -----**<br>
Data sheet no. 10771
Eaton.com/bussmannseries
13-16
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
Dimensions — mm
2-Pole, UL Type 1 DIN-Rail high SCCR surge protective devices
**==> picture [9 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
30<br>**----- End of picture text -----**<br>
**==> picture [65 x 44] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>><br>**----- End of picture text -----**<br>
Catalog symbol:
- BSPMA2_S3GR
## Description:
**==> picture [250 x 215] intentionally omitted <==**
**----- Start of picture text -----**<br>
es |<br>90 45<br>36 43.5<br>it c 7<br>65<br>9<br>on<br>15.3 11<br>eee<br>**----- End of picture text -----**<br>
The Bussmann™ series two-pole DIN-Rail UL Listed Type 1 surge protective devices feature a high 200 kA SCCR. Replaceable arrestor modules are mechanically coded with the base to ensure against installing an incorrect replacement. The unique module locking system fixes the module to the base, and allows it to be easily replaced without tools by simply depressing the release buttons.
## Standard local visual status indication:
The module’s visual indicator shows the protective status at a glance: green = good, red = replace.
## Remote contact signaling:
The standard three-pole terminal remote Form C contact signaling relay has a floating changeover contact for use as a break or make contact, according to circuit concept.
## Ratings:
- System volts/types
- 120/240 Vac split-phase
- 240/480 Vac split-phase
- Short-circuit Current Rating (SCCR) 200 kA
## Agency information:
- UL Listed open Type 1, ANSI/ UL 1449 4[th] Edition, Guide VZCA, VZCA7
- CSA Type 4-1 Component Assembly, C22.2 No. 269.1-14, Class 2157-27
- RoHS compliant
## Mounting
- 35mm Din-Rail
## Warranty
- Five years
Data sheet no. 10772
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-17
## **13 — Surge protective devices**
|Specifications/orderinginformation||||
|---|---|---|---|
|System voltage/type|120/240 Vac split-phase|240/480 Vac split-phase||
|Catalognumber|BSPMA2240S3GR||BSPMA2480S3GR|
|Replacement module catalognumber (qty.)|BPMA230UL (2)||BPMA385UL (2)|
|SPD classper ANSI/UL 1449 4thEd.||Open-Type 1 SPD||
|SPD classper CSA - C22.2 No. 269.1-14|Type 4-1 Component Assembly|||
|Nominal system voltage (UN) [L-G] / [L-L]|127 Vac / 254 Vac||240 Vac / 480 Vac|
|Nominalpower frequency||50 / 60 Hz||
|Max. continuous operatingvoltage AC (MCOV) [L-G] / [L-L]|230 Vac / 460 Vac||385 Vac / 770 Vac|
|Nominal discharge current (In) (8x20µs)||20 kA||
|Max. discharge current (Imax) (8/20)||50 kA||
|Voltage Protection Rating(VPR) [L-G] / [L-L]|700 Vpk/ 1500 Vpk|1200 Vpk/ 2500 Vpk||
|Short Circuit Current Rating(SCCR)||200 kA||
|Operatingtemperature range (TU) °F (°C)||-31 to 185 (-35 to 85)||
|Operatingstate / fault indication|Green =good ; Red = replace|||
|Wire range (60/75°C Cu, solid/stranded)||2-14 AWG (2.5-25 mm2)||
|Terminal torque — lb-in (N•m)||35-45 (4-5.1)||
|Mounting|35mm DIN-Railper EN 60715|||
|Enclosure material|Thermoplastic, UL 94 V0|||
|Protection||IP20 (finger-safe)||
|Capacity||2 module(s), DIN 43880||
|Agencyinformation|UL Listed, Guide VZCA, VZCA7/CSA Component Acceptance Class 2157-27, RoHS|||
|Weight - oz (g)|7.94 (225)||8.57 (243)|
|Contact signaling||||
|Signalingtype|Floating(dry), Form C (SPDT)|||
|NEC®Circuits|NEC Class 2 circuits only|||
|SwitchingcapacityAC (DC)|250 V/5 A (250 V/0.1 A, 125 V/0.2 A, 75||V/0.5 A)|
|Wire range (60/75 °C Cu, solid/stranded)|16-22 AWG (1.5-0.34mm2)|||
|Terminal torque — lb-in (N•m)||1.8 (0.2)||
## Typical installation/system application:
**==> picture [440 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>L1<br>L1 L1<br>N N<br>L2<br>L2<br>L2 L2<br>Gnd<br>Gnd<br>L3 Gnd<br>**----- End of picture text -----**<br>
**==> picture [64 x 72] intentionally omitted <==**
Data sheet no. 10772
Eaton.com/bussmannseries
13-18
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
3-Pole, UL Type 1 DIN-Rail high SCCR surge protective devices
Dimensions — mm
**==> picture [65 x 57] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>@><br>**----- End of picture text -----**<br>
## Catalog symbol:
- BSPMA3_WYGR
- BSPMA3_DLGR
## Description:
The Bussmann™ series three-pole DIN-Rail UL Listed Type 1 surge protective devices feature a high 200 kA SCCR. Replaceable arrestor modules are mechanically coded with the base to ensure against installing an incorrect replacement. The unique module locking system fixes the module to the base, and allows it to be easily replaced without tools by simply depressing the release buttons.
## Standard local visual status indication:
The module’s visual indicator shows the protective status at a glance: green = good, red = replace.
## Remote contact signaling:
The standard three-pole terminal remote Form C contact signaling relay has a floating changeover contact for use as a break or make contact, according to circuit concept. Ratings:
- System volts/types
- 120/208 Vac 3-phase Wye
- 277/480 Vac 3-phase Wye
- 347/600 Vac 3-phase Wye
- 240 Vac 3-phase Delta
- 480 Vac 3-phase Delta
- Short-circuit Current Rating (SCCR) 200 kA
## Agency information:
- UL Listed open Type 1, ANSI/ UL 1449 4[th] Edition, Guide VZCA, VZCA7
- CSA Type 4-1 Component Assembly, C22.2 No. 269.1-14, Class 2157-27
- RoHS compliant
## Mounting
- 35mm Din-Rail
## Warranty
- Five years
Data sheet no. 10773
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-19
## **13 — Surge protective devices**
|Specifications/ordering information|Specifications/ordering information||||||
|---|---|---|---|---|---|---|
|System voltage/type|120/208 Vac 3-phase Wye|277/480 Vac 3-phase Wye||347/600 Vac 3-phase Wye|240 Vac 3-phase Delta|480 Vac 3-phase Delta|
|Catalog number|BSPMA3208WYGR|BSPMA3480WYGR||BSPMA3600WYGR|BSPMA3240DLGR|BSPMA3480DLGR|
|Replacement module<br>catalog number (qty.)|BPMA180UL (3)|BPMA385UL (3)||BPMA510UL (3)|BPMA275UL (3)|BPMA550UL (3)|
|SPD class acc. to ANSI/UL<br>1449 4th Ed.||||Open-Type 1 SPD|||
|SPD class acc. to CSA -<br>C22.2 No. 269.1-14|||Type 4-1 Component Assembly||||
|Nominal system voltage (UN)<br>[L-G] / [L-L]|120 Vac / 208 Vac|277 Vac / 480 Vac||347 Vac / 600 Vac|240 Vac / 240 Vac|480 Vac / 480 Vac|
|Nominal power frequency||||50 / 60 Hz|||
|Max. continuous operating|||||||
|voltage AC (MCOV) [L-G] /|180 Vac / 360 Vac|385 Vac / 770 Vac||510 Vac / 1020 Vac|275 Vac / 550 Vac|550 Vac / 1100 Vac|
|[L-L]|||||||
|Nominal discharge current<br>(I~~n~~) (8x20µs)||||20 kA|||
|Max. discharge current (Imax)<br>(8/20)||||50 kA|||
|Voltage Protection Rating<br>(VPR) [L-G] / [L-L]|600 Vpk/ 1200 Vpk|1200 Vpk/ 2500 Vpk||1500 Vpk/ 3000 Vpk|800 Vpk/ 1500 Vpk|1800 Vpk/ 3000 Vpk|
|Short Circuit Current Rating<br>(SCCR)||||200 kA|||
|Operating temperature<br>range (T~~U~~)°F (°C)||||-31 to 185 (-35 to 85)|||
|Operating state / fault<br>indication|||Green = good ; Red = replace||||
|Wire range (60/75°C Cu,<br>solid/stranded)||||4-14 AWG (2.5-25 mm2)|||
|Terminal torque||||35-45 (4-5.1)|||
|Mounting|||35|mm DIN-Rail per EN 60715|||
|Enclosure material||||Thermoplastic, UL 94 V0|||
|Protection||||IP20 (finger-safe)|||
|Capacity||||3 module(s), DIN 43880|||
|Agency information||UL Listed, Guide VZCA, VZCA7/CSA Component Acceptance|||Class 2157-27, RoHS||
|Weight-oz (g)|10.93 (310)|12.24 (347)||13.05 (370)|11.46 (325)|13.4 (380)|
|Contact signaling|||||||
|Signaling type|||Floating (dry), Form C (SPDT)||||
|NEC Circuits||||NEC Class 2 circuits only|||
|Switching capacity AC (DC)||250 V/5 A (250 V/0.1 A, 125 V/0.2 A, 75 V/0.5 A)|||||
|Wire range (60/75°C Cu,<br>solid/stranded)|||16-22 AWG (1.5-0.34mm2)||||
|Terminal torque-lb-in (N•m)||||1.8 (0.2)|||
## Typical installation/system application:
**==> picture [88 x 104] intentionally omitted <==**
**==> picture [352 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1 L1<br>L1<br>L2<br>L2<br>L2<br>L3<br>L3<br>L3<br>Gnd<br>Gnd Gnd<br>**----- End of picture text -----**<br>
Data sheet no. 10773
Eaton.com/bussmannseries
13-20
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
4-Pole, UL Type 1 DIN-Rail high SCCR surge protective devices
Dimensions — mm
**==> picture [45 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
## Catalog symbol:
- BSPMA4_WYNGR
## Description:
The Bussmann™ series four-pole DIN-Rail UL Listed Type 1 surge protective devices feature a high 200 kA SCCR. Replaceable arrestor modules are mechanically coded with the base to ensure against installing an incorrect replacement. The unique module locking system fixes the module to the base, and allows it to be easily replaced without tools by simply depressing the release buttons.
## Standard local visual status indication:
The module’s visual indicator shows the protective status at a glance: green = good, red = replace.
## Remote contact signaling:
The standard three-pole terminal remote Form C contact signaling relay has a floating changeover contact for use as a break or make contact, according to circuit concept.
## Ratings:
- System volts/types
- 120/208 Vac 3-phase Wye
- 277/480 Vac 3-phase Wye
- Short-circuit Current Rating (SCCR) 200 kA
## Agency information:
- UL Listed open Type 1, ANSI/ UL 1449 4[th] Edition, Guide VZCA, VZCA7
- CSA Type 4-1 Component Assembly, C22.2 No. 269.1-14, Class 2157-27
- RoHS compliant
## Mounting
- 35mm Din-Rail
## Warranty
- Five years
Data sheet no. 10774
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-21
## **13 — Surge protective devices**
**==> picture [537 x 13] intentionally omitted <==**
**----- Start of picture text -----**<br>
Specifications/ordering information System volts/catalog no.<br>**----- End of picture text -----**<br>
|System voltage/type|120/208 Vac 3-ph|ase Wye<br>277/48|0 Vac 3-phase Wye|
|---|---|---|---|
|Catalognumber|BSPMA4208WYNGR<br>BSPMA4480WYNGR|||
|Replacement module catalognumber(qty.)|BPMA180UL|(4)<br>BPMA385UL(3),BPMA180UL(1)||
|SPD class acc. to ANSI/UL 1449 4thEd.||Open-Type 1 SPD||
|SPD class acc. to CSA - C22.2 No. 269.1-14||Type 4-1 Component Assembly||
|Nominal system voltage(U~~N~~) [L-N] / [L-G] / [L-L] / [N-G]|120 Vac/120 Vac/208 Vac/0 Vac<br>277 Vac/277 Vac/480 Vac/0 Vac|||
|Nominalpower frequency||50/60 Hz||
|Max. continuous operatingvoltage AC(MCOV) [L-N] / [L-G] / [L-L] / [N-G]|180 Vac/360 Vac/360 Vac/180 Vac<br>385 Vac/565 Vac/770 Vac/180 Vac|||
|Nominal discharge current(I~~n~~) (8x20µs)||20 kA||
|Max. discharge current(I~~max~~) (8/20)||50 kA||
|Voltage Protection Rating (VPR) [L-N] / [L-G] / [L-L] / [N-G]|600 V~~pk~~ /1200 V~~pk~~ /1200 V~~pk~~ /600 V~~pk~~<br>1200 V~~pk~~ /1800 V~~pk~~ /2500 V~~pk~~ /600 V~~pk~~|||
|Short Circuit Current Rating (SCCR)||200 kA||
|Operatingtemperature range(T~~U~~)°F(°C)||-31 to 185(-35 to 85)||
|Operatingstate/fault indication||Green =good;Red = replace||
|Wire range(60/75°C Cu,solid/stranded)||4-14 AWG(2.5-25 mm2)||
|Terminal torque — lb-in(N•m)||35-45(4-5.1)||
|Mounting||35 mm DIN-Railper EN 60715||
|Enclosure material||Thermoplastic,UL 94 V0||
|Protection||IP20(finger-safe)||
|Capacity||4 module(s),DIN 43880||
|Agency information|UL Listed, Guide VZCA, VZCA7/CSA Component Acceptance Class 2157-27,<br>RoHS|||
|Weight - oz(g)|13.9(394)||15.24(432)|
|Contact signaling||||
|Signalingtype||Floating (dry),Form C(SPDT)||
|NEC Circuits||NEC Class 2 circuits only||
|SwitchingcapacityAC(DC)|250 V/5 A(250 V/0.1 A,125 V/0.2 A,75||V/0.5 A)|
|Wire range(60/75°C Cu,solid/stranded)||16-22 AWG(1.5-0.34mm2)||
|Terminal torque - lb-in(N•m)||1.8(0.2)||
## Typical installation/system application:
**==> picture [89 x 114] intentionally omitted <==**
**==> picture [17 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>N<br>L2<br>L3<br>Gnd<br>**----- End of picture text -----**<br>
Data sheet no. 10774
Eaton.com/bussmannseries
13-22
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
## BSPM1A_ _ _ _LV(R) low voltage power SPDs
## Dimensions — mm
The Bussmann series UL Type 4, 75 Vac/100 Vdc, 120 Vac/200 **2011/65/EU** Vdc single pole, modular surge arresters feature local, easyID™ visual indication and remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
## LV power system arresters
The features of these single-pole devices are for use as a single device or in combination with other devices for AC and DC voltage systems.
- Surge arrester according to UL 1449 4[th] Edition, Type 4 Component Assembly for use in Type 2 applications helps meet UL 508A requirements*
- Proven MOV technology for reliable surge protection
- "Thermo Dynamic Control" SPD monitoring device ensures high reliability against surge events
- Module locking system with module release button make module replacement easy without tools
- Remote signaling of all protection modules make status monitoring easy and accurate in any monitoring scheme
- No additional upstream overcurrent protection necessary to make installation easier and more economical
- Vibration and shock tested according to EN 60068-2 to withstand harsh environments
- Except as noted in data sheet no. 2056.
## Remote signaling Form C contact
The remote signaling contact versions have a floating changeover contact for use as a break or make contact for easy adoption in any monitoring application.
Data sheet no. 2056
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-23
**13 — Surge protective devices**
## Catalog numbers and specifications
**==> picture [537 x 439] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering information — for 75 Vac/100 Vdc to 120 Vac/200 Vdc System volts/catalog no.<br>System voltage 75 Vac/100 Vdc 120 Vac/200 Vdc<br>Catalog no. (base + modules) With remote signaling BSPM1A75D100LVR BSPM1A150D200LVR<br>Replacement modules BPMA75D100LV BPMA150D200LV<br>Specifications<br>Max. continuous operating AC voltage [VC] 75 Vac 150 Vac<br>Voltage protection level [VPL] ≤0.4 kV ≤0.7 kV<br>Voltage protection level at 5 kA [VPL] ≤0.35 kV ≤0.55 kV<br>Max. continuous operating DC voltage [VC] 100 Vdc 200 Vdc<br>Nominal discharge current (8/20µs) [In] AC 10 kA 15 kA<br>Nominal discharge current (8/20µs) [In] DC 10 kA 12.5 kA<br>Surge current capacity(8/20µs) [Imax] 40 kA 40 kA<br>Temporary overvoltage (TOV) 90 V / 5 sec. 175 V / 5 sec.<br>Agency information* UL / cUL, CSA, KEMA UL / cUL, CSA, KEMA<br>Specifications — all catalog numbers<br>SPD according to EN 61643-11 Type 2<br>SPD according to IEC 61643-1 Class II<br>Response time [tA] ≤25ns<br>TOV characteristics Withstand<br>Operating temperature range [TU] -40°C to +80°C<br>Operating state/fault indication Green (good) / red (replace)<br>Number of ports 1<br>Cross-sectional area (minimum) 14 AWG solid/stranded<br>Cross-sectional area (maximum) 1 AWG solid — 2 AWG stranded<br>Mounting 35mm DIN-Rail per EN 60715<br>Enclosure material Thermoplastic, UL 94V0<br>Location category Indoor<br>Degree of protection IP20<br>Capacity 1 module, DIN 43880<br>Warranty Five years**<br>Remote contact signaling<br>Remote contact signaling type Changeover contact<br>AC switching capacity (volts/amps) 250 V/0.5 A<br>DC switching capacity (volts/amps) 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A<br>Conductor ratings / cross-sectional area for remote contact signal ter- 60/75°C Max. 14 AWG solid/stranded<br>minals<br>Ordering information Order from catalog numbers above<br>**----- End of picture text -----**<br>
* Agency information not applicable to DC ratings.
** See Limited Warranty Statement 3A1502 for details at Eaton.com/bussmannseries.
Data sheet no. 2056
Eaton.com/bussmannseries
13-24
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
## BSPH2A_ _ _ _LVR low voltage control SPDs
## Dimensions — mm
The Bussmann series UL Type 4 24 Vac/dc, 48 Vac/dc, 60 Vac/ **2011/65/EU** dc, 120 Vac/dc and 230 Vac/ dc, two-pole, modular surge arresters feature local, easyID visual indication and remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module.
LV system arresters
The features of these two-pole devices are for use in coordination with other upstream SPDs in UL 508A Applications*.
- Surge arrester according to UL 1449 4[th] Edition, Type 4 Component Assembly for use in Type 3 applications helps meet UL 508A requirements
- Proven MOV and GDT hybrid technology for reliable surge protection
- "Thermo Dynamic Control" SPD monitoring device ensures high reliability against surge events
- Module locking system with module release button make module replacement easy without tools
- Remote signaling on all protection modules make status monitoring easy and accurate in any monitoring scheme
- No additional upstream overcurrent protection needed so installation is easier and more economical
- Vibration and shock tested according to EN 60068-2 to withstand harsh environments
- UL 1449 4[th] Edition not applicable to DC voltages.
## Remote signaling Form C contact
Remote signaling has a floating changeover contact for use as a break or make contact for easy application in any monitoring system.
Data sheet no. 2057
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-25
**13 — Surge protective devices**
Catalog numbers and specifications
**==> picture [537 x 456] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ordering information System volts/catalog no.<br>System voltage 24 Vac/dc 48 Vac/dc 120 Vac/dc<br>Max. continuous operating AC voltage (MCOV) [VC] 30 Vac/dc 60 Vac/dc 150 Vac/dc<br>Catalog no.(base + modules) BSPH2A24D24LVR BSPH2A48D48LVR BSPH2A150D150LVR<br>Replacement Modules BPHA24D24LV BPHA48D48LV BPHA150D150LV<br>Specifications<br>Nominal AC voltage [Vo] 24 V 48 V 120 V<br>Max. continuous operating AC voltage [VC] 30 V 60 V 150 V<br>Max. continuous operating DC voltage [VC] 30 V 60 V 150 V<br>Nominal discharge current (8/20µs) [In] 1 kA 1 kA 2 kA<br>Total discharge current (8/20µs) [L+N-Gnd] [Itotal] 2 kA 2 kA 4 kA<br>Nominal load current AC [IL] 25 A 25 A 25 A<br>Combined impulse [UOC] 2 kV 2 kV 4 kV<br>Combined impulse [L+N-Gnd] [UOC total] 4 kV 4 kV 8 kV<br>Voltage protection level [L-N] [VPL] ≤180 V ≤350 V ≤640 V<br>Voltage protection level [L/N-Gnd] [VPL] ≤630 V ≤730 V ≤800 V<br>SPD according to EN 61643-11 Type 3<br>SPD according to IEC 61643-1 Class III<br>Response time [L-N] [tA] ≤25ns<br>Response time [L/N-Gnd] [tA] ≤100ns<br>Operating temperature range [TU] -40°C to +80°C<br>Operating state/fault indication Green (good) / red (replace)<br>Number of ports 1<br>Cross-sectional area (min.) 18 AWG solid/stranded<br>Cross-sectional area (max.) 10 AWG solid/12 AWG stranded<br>For mounting on 35mm DIN-Rail per EN 60715<br>Enclosure material Thermoplastic, UL 94V0<br>Location category Indoor<br>Degree of protection IP20<br>Capacity 1 Module, DIN 43880<br>Agency information* UL / cUL, CSA, KEMA<br>Product warranty Five years**<br>Remote contact signaling<br>Remote contact signaling type Changeover contact<br>AC switching capacity (volts/amps) 250 V/0.5 A<br>DC switching capacity (volts/amps) 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A<br>Conductor ratings and cross-sectional area for remote contact 60/75°C Max. 14 AWG solid/stranded<br>signal terminals<br>Ordering information Order from catalog numbers above<br>**----- End of picture text -----**<br>
* Agency information not applicable to DC ratings.
** See Limited Warranty Statement 3A1502 for details at Eaton.com/bussmannseries.
Data sheet no. 2057
Eaton.com/bussmannseries
13-26
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
## BSPD48RJ45 DIN-Rail RJ45/Ethernet cable SPD
The Bussmann series DIN-Rail mount BSPD48RJ45 Surge Protective Device (SPD) is a UL Listed 497B universal DIN-Rail mount surge protective device for RJ45/Ethernet cable systems. It is easy to install or retrofit Ethernet cable systems with RJ connectors.
The BSPD48RJ45 is installed between the patch panel and the active component (a switch for example). The snap-in mechanism of the supporting foot allows the SPD to be safely grounded via the DIN-Rail. For single applications, the BSPD48RJ45 comes with a supplied mounting bracket with cable lug.
Fulfilling the requirements of Category 6, the BSPD48RJ45 can be universally used for all data services up to nominal voltages of 48 V. It is well suited for existing services such as Gigabit Ethernet, ATM, ISDN, Voice over IP and Power over Ethernet (PoE+ acc. to IEEE 802.3at up to 57 V) and similar applications in structured cabling systems according to Class E up to 250 MHz. Protection of all pairs by means of powerful gas discharge tubes and one adapter filter matrix per pair.
- UL 497B Listed
- Easy to install or retrofit for protection of all lines
- CAT 6 according to ISO/IEC 11801
- CAT 6 in the channel (Class E)
- Power over Ethernet (PoE+ according to IEEE 802.3at)
## DIN-Rail RJ45 SPDs applications
|DIN-Rail RJ45 SPDs applications|DIN-Rail RJ45 SPDs applications|
|---|---|
|Catalogno.<br>BSPD48RJ45<br>Bus systems, and measuringand control technology<br>Industrial Ethernet<br>X||
|Data networks<br>ATM<br>Ethernet 10/100/1000|X<br>X|
|FDDI, CDDI|X|
|Industrial Ethernet|X|
|Power over Ethernet (PoE)<br>Token Ring<br>VG anyLAN<br>Video systems|X<br>X<br>X|
|Video (2 wire)|X|
## Dimensions — mm
**==> picture [133 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
19.00<br> 11.72<br>a [|] —_—<br>= m_<br> 76.91<br>——— J<br>|_|<br> 36.15<br>**----- End of picture text -----**<br>
## Catalog numbers and specifications
|Catalog numbers and specifications||||
|---|---|---|---|
|Catalogno.<br>Nominal voltage(U~~N~~)<br>Max. continuous operatingDC voltage(U~~C~~)<br>Max. continuous operatingAC voltage(U~~C~~)<br>Max. continuous DC voltagepair-pair(PoE) (U~~C~~)<br>Nominal current(I~~L~~)<br>C2 Nominal discharge current (8/20µs) line-line<br>(I~~n~~)<br>C2 Nominal discharge current (8/20µs) line-PG<br>(I~~n~~)|BSPD48RJ45<br>48 V<br>48 V<br>34 V<br>57 V<br>1 A<br>150 A<br>2.5 kA|Surge protective|devices|
|C2 Total nominal discharge current (8/20µs) line-<br>PG(I~~n~~)|10 kA|||
|C2 Nominal discharge current (8/20µs) pair-pair<br>(PoE) (I~~n~~)|150 A|||
|Voltageprotection level line-line for In C2(U~~P~~)<br>Voltageprotection level line-PG for In C2(U~~P~~)|≤190 V<br>≤600 V|||
|Voltage protection level line-line for In C2 (PoE)<br>(U~~P~~)|≤600 V|||
|Voltage protection level line-line at 1 kV/µs C3<br>(U~~P~~)|≤180 V|||
|Voltage protection level line-PG at 1 kV/µs C3<br>(U~~P~~)|≤500 V|||
|Voltage protection level pair-pair at 1 kV/µs C3<br>(PoE) (U~~P~~)|≤600 V|||
|Insertion loss at 250MHz|≤3 dB|||
|Capacitance line-line(C)|≤30pF|||
|Capacitance line-PG(C)|≤25pF|||
|Operatingtemperature range|-40°C to +80°C|||
|Degree ofprotection|IP10|||
|Mounting|35mm DIN-Rail per<br>EN 60715|||
|Connection (input / output)|RJ45 socket / RJ45<br>socket|||
|Pinning|1/2,3/6,4/5,7/8|||
|Grounding|Via 35mm DIN-Rail<br>per EN 60715|||
|Enclosure material|Die cast zinc|||
|Color|Bare surface|||
|Test standards|IEC 61643-21 / EN<br>61643-21|||
|Agencyinformation|UL 497B|||
|Warranty|Fiveyears*|||
- See Limited Warranty Statement 3A1502 for details at Eaton.com/ bussmannseries.
Data sheet no. 2160
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-27
**13 — Surge protective devices** ~~Fe~~
## BSPD_DING_ DIN-Rail 4 wire SPDs
The Bussmann series universal fourpole, DIN-Rail mounted surge arrester is UL Listed 497B DIN-Rail mount universal surge protective device. It requires minimum space, while providing effective protection for the stringent requirements of measuring and control circuits, and bus systems.
To ensure safe operation, the arrester provides protection against vibration and shock up to a 30-fold acceleration of gravity. The device's functionoptimized design allows quick and easy protection module removal via “make-before-break” terminals that assure data signal continuity in the protected and unprotected state.
For IEC Applications - Instruction for Surge Protective Device Use In Zone 2 Explosive Atmospheres per ATEX.
1. When installed in potentially explosive atmospheres, the Data Signal SPD shall be installed into an enclosure which meets the requirements of a recognized type of protection, in accordance with EN 60079-0.
2. The Data Signal DIN SPD as transient suppressor. This approval applies to the following equipment types:
- BSPD5DINLHF
## Ambient and temperature class
- -40°C to 80°C, T4: DEKRA 12ATEX0254 X: II 3 G Ex nA IIC T4 Gc
- Standards used for: ATEX: EN60079-0: 2009, EN 60079-15: 2005
- UL 497B Listed
- Function-optimized design for safe use and easy installation
- Four-pole and base mounts on grounded 35mm DIN-Rail
- Module removal without signal interruption via “make-beforebreak” circuitry
Dimensions — mm
**==> picture [189 x 182] intentionally omitted <==**
**----- Start of picture text -----**<br>
71.99<br> 50.49<br> 35.51<br>12.00 16.09<br>aa<br>90.00 45.00<br> 6.70<br> 49.99<br>3.97<br>**----- End of picture text -----**<br>
## DIN-Rail universal 4 wire data signal SPD applications
Universal 4 wire data signal SPD is specified by communication technology.
The table below contains the specific technology to which the BSPD5DINLHF is suited to be used.
~~ee~~ System type Bus systems and measuring, and control technology CAN-Bus (data line only) C-Bus (Honeywell) Device Net (data line only) FSK IEC-Bus (RS485) Interbus INLINE, LON - TP/XF 78 MODBUS MPI Bus Procontic T200 (RS422) PROFIBUS DP/FMS PROFIBUS SIMATIC NET PSM EG RS422 & RS485 Rackbus (RS485) R Bus RS 485 RS422, V11 SafetyBUS p Securilan LON Bus SUCONET
The table below contains the specific technology to which the BSPD24DING is suited to be used.
~~ee~~ System type Bus systems and measuring, and control technology 0-20mA, 4-20mA signals Binary signals TTYy 4-20mA
Data sheet no. 2161
Eaton.com/bussmannseries
13-28
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Surge protective devices — 13**
Catalog numbers and specifications
**==> picture [562 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catalog number BSPD24DING BSPD5DINLHF<br>**----- End of picture text -----**<br>
|Catalognumber<br>|BSPD24DING<br>BSPD5DINLHF<br> <br>|
|---|---|
|Nominal voltage (UN)|Surge protective<br>devices<br>24 V<br>5 V<br>0.75 A<br>1.0 A<br>≤102 V<br>≤25 V<br>≤66 V<br>≤550 V<br>≤90 V<br>≤11 V<br>≤45 V<br>≤550 V<br>10 kA<br>10 kA<br>2.5 kA<br>2.5 kA<br>20 kA<br>20 kA<br>10 kA<br>10 kA<br>1.8 Ω<br>1.0 Ω<br>33 V<br>6 V<br>23.3 V<br>4.2 V<br>6.8 MHz<br>100 MHz<br>≤0.5 nF<br>≤25pF<br>≤1.0 nF<br>≤16pF<br>†<br>†<br>††<br>††<br>D1, C2, C3<br>-40°C to +80°C<br>IP20<br>35mm DIN-Railsper EN 60715<br>Via basepart<br>Grey/ Polyamide PA 6.6<br>IEC 61643-21 / EN 61643-21, UL 497B<br>Screw terminal<br>Solid: 12-28 AWG (4-0.08 mm2)<br>Flexible: 14-28A WG (2.5-0.08 mm2)<br>3.5 Lb-In (0.4 N•m)<br>5 Years*|
|Nominal current at 45°C (IL)||
|VPL line-line for IimpD1 (Up)||
|VPL line-PG for IimpD1 (Up)||
|VPL line-line at 1 kV/µs C3 (Up)||
|VPL line-PG at 1 kV/µs C3 (Up)||
|D1 Total lightningimpulse current (10/350µs) (Iimp)||
|D1 Lightningimpulse current (10/350µs)per line (limp)||
|C2 Total nominal discharge current (8/20µs) (In)||
|C2 Nominal discharge current (8/20µs)per line (In)||
|Series impedanceper line||
|Max. continuous operatingDC voltage (UC)||
|Max. continuous operatingAC voltage (UC)||
|Cut-off frequencyline-PG (fG)||
|Capacitance line-line (C)||
|Capacitance line-PG (C)||
|ATEX Approvals||
|Agencyinformation||
|IEC 61643-21 test category||
|Operatingtemperature range||
|Degree ofprotection||
|For mountingon||
|Grounding||
|Color / enclosure material||
|Test standards||
|Connection (input / output)||
|Conductors||
|Terminal torque||
|Warranty||
* See Bussmann series SPD Limited Warranty Statement (3A1502) for details at Eaton.com/bussmannseries.
† DEKRA 12ATEX0254 X: II 3 G Ex nA IIC T4 Gc.
†† ATEX, UL, CSA.
Data sheet no. 2161
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
13-29
## **The power of space**
The revolutionary **Bussmann[TM] series Low-Peak[TM] CUBEFuse[TM]** delivers the smallest footprint
**CUBEFuse.com**
**Telecom protection products — 14**
## Contents
## Circuit protection for telecom applications
||Description|Poles|Volts<br>DC|Amps|Section<br>page|
|---|---|---|---|---|---|
||Fused pullout disconnects and related fuses|||||
||Compact TPCDS with TCP fuses<br>Miniature TPMDS with TPM<br>fuses<br>TP1590-4 for TPA fuses<br>TP15914 for TPA fuses|1<br>1<br>4<br>4|80<br>80<br>145/80<br>145|3-125<br>3-30<br>40/50<br>50|2<br>3<br>4|
||TPA (170 Vdc) and TPA-B (65<br>Vdc) fuses<br>15800 for TPS fuses and GMT-A<br>open fuse indicator|—<br>1|170/65<br>60|3-40<br>3-70|5|
||TPS fuses and TP158HC for<br>TPL-B power fuses and GMT-A<br>open fuse indicator|1|80|70-250|6|
||15100 for TPL fuses<br>TPHCS for TPL fuses|1<br>1|60<br>80|70-800<br>70-800|7|
||TPL fuses|—|170|70-800|8|
||Fuses and fuse holders|||||
||TPN current-limiting DC fuses|—|170|1-600|9|
|70 Type indicating fuses<br>~~a~~||—|125 AC<br>300 DC|1/10-10|10|
||15087 holders for 70 Type fuses|1|300|12||
||HLS, HLT and PCT holders for<br>GMT fuses<br>GMT fast-acting fuses|Up to<br>25<br>—|125 AC<br>60 DC<br>125 AC<br>60 DC|15<br>18/100<br>to 3|11|
GMT-A fast-acting open fuse indicator for use with 15800 and TP158HC disconnects
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
14-1
**14 — Telecom protection products**
## TPC fuses and TPCDS pullout disconnects
Telpower TPC compact currentlimiting fuses mount in the TPCDS compact fused pullout disconnect that’s available in two disconnect profiles and a variety of terminal styles. Recommended 0.75" center-tocenter product spacing.
## Ratings
- Volts 80 Vdc
- Amps 3-125 A
- IR 100 kA
## Agency information
- UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout
- Recognized to US and Canadian requirements under the component recognition program of Underwriters Laboratories Inc. Files E219046 and E56412
- CE
## Typical applications
- Telecommunications DC power circuit protection
## TPCDS catalog number system
|Catalogno.|no.prefix|
|---|---|
|TPCDS-|TPCDS-D-|
|Terminal style|Terminal style|
|BB -<br>Bullet contact on the line,<br>bullet contact on the load|CC -<br>Screw Clamp terminal<br>on the line, screw Clamp<br>terminal on the load|
|BS -<br>Bullet contact on the line,<br>stud terminal on the load|BC -<br>Bullet contact on the line,<br>screw Clamp terminal on<br>the load|
|SS -<br>Stud terminal on the line,<br>stud terminal on the load|SEC -<br>Stud terminal on the line,<br>English threads for stud<br>(10-32), screw Clamp<br>terminal on the load|
|—|SMC -<br>Stud terminal on the<br>line, metric threads for<br>stud (M5), screw Clamp<br>terminal on the load|
|Thread|N/A|
|M -<br>Metric threads for panel<br>mount fasteners (M3) and<br>stud(M5)|—|
|E -<br>English threads for panel<br>mount fasteners (6-32) and<br>stud(10-32)||
|Remote alarm terminal distance|Remote alarm terminal distance|
|1 -<br>0.645 inch from line<br>terminal|1 -<br>Side ouput (available on CC<br>and BC terminal styles)|
|2 -<br>0.970 inch from line<br>terminal|2 -<br>Bottom output, .970 inch<br>from line terminal (available<br>on BC terminal style only)|
|3 -<br>1.285 inch from line terminal|—|
- Replacement of DC telecom circuit breakers
- Applications where venting of arc or molten metals and gases during opening would pose a problem to surrounding devices
## Features
- Highest interrupting rating (100 kA) available and complete system coordination for DC circuit protection for compact footprint providing a superior protection solution for replacement of existing DC telecom circuit breakers
- AmpColor ID™ system makes fuse replacement easy
- Local and remote open fuse indication. Local alarm indication provided by LED on TPC fuse
- Remote alarm terminal available in three positions common to DC circuit protection devices
|Catalog no.||||
|---|---|---|---|
|TPCDS-BBE-1|TPCDS-BSE-2|TPCDS-SSE-3|TPCDS-D-SEC1*|
|TPCDS-BBE-2|TPCDS-BSE-3|TPCDS-SSM-1|TPCDS-D-SEC2*|
|TPCDS-BBE-3|TPCDS-BSM-1|TPCDS-SSM-2|TPCDS-D-SMC1*|
|TPCDS-BBM-1|TPCDS-BSM-2|TPCDS-SSM-3|TPCDS-D-SMC2*|
|TPCDS-BBM-2|TPCDS-BSM-3|TPCDS-D-BC1*||
|TPCDS-BBM-3|TPCDS-SSE-1|TPCDS-D-BC2*||
|TPCDS-BSE-1|TPCDS-SSE-2|TPCDS-D-CC1*||
* Not investigated to Canadian requirements.
## Dimensions
- See data sheet no. 5023
## TPC fuses
|Catalog no. (amps)||||
|---|---|---|---|
|TPC-3|TPC-8|TPC-25|TPC-75|
|TPC-4|TPC-10|TPC-30|TPC-90|
|TPC-5|TPC-12|TPC-40|TPC-100|
|TPC-6|TPC-15|TPC-50|TPC-125|
|TPC-7|TPC-20|TPC-60||
Data sheet no. 5023
Eaton.com/bussmannseries
14-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Telecom protection products — 14**
## TPM fuse and TPMDS pullout disconnect
Telpower TPM miniature current-limiting fusses mount in the miniature TPMDS pullout disconnect. The TPM fuses feature local open fuse indication and TPMDS is easily integrated into remote indication systems.
## Ratings
- Volts 80 Vdc
- Amps 3-30 A
- IR 20 kA
## Agency information
- UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout
- Recognized to US and Canadian requirements under the component recognition program of Underwriters Laboratories Inc. Files E219046 and E56412
## TPMDS alarm schematic
Notes:
1. The resistance (R) must be
BIPOLARLED provided by the end-user to
| limit the open fuse indication output current to a maximum
|| of 20mA. The “R” value
HH should be calculated using
|| the system voltage value. If | | remote indication functionality is not required, the ENDUSER CIRCUITRY must still be supplied to provide a resistance path to the return for the local indication to properly function.
- 2 The fuse is polarized to maintain proper orientation with the switch housing. The line and load terminals are identified on the switch housing.
- CE
## Typical applications
- Telecommunications DC power circuit protection
- Applications with restricted space, or mounting in 1 U (1.75"/44.5mm) panels
## Features
- Smallest and most versatile fused disconnect switch available allowing for assembly into 1 U (1.75"/44.5mm) panel. Easy to connect:
- Load: 1/4" quick-connect or bolted connection with 10-32 (M5) captive nut
- Line: 1/4" quick-connect or screw connection with clearance hole for #10 (M5) bolt
- AmpColor ID™ System makes fuse replacement easy
- Switch design provides for easy panel mounting by single captive 4-40 (M3) nut and panel notch integral to switch footprint
- Complete system coordination capability with local and remote open fuse indication. Local alarm indication provided by LED on TPM fuse (maximum alarm circuit current: 20 mA)
## TPM fuses
|Catalog no. (amps)||||
|---|---|---|---|
|TPM-3|TPM-6|TPM-10|TPM-20|
|TPM-4|TPM-7|TPM-12|TPM-25|
|TPM-5|TPM-8|TPM-15|TPM-30|
TPMDS pullout disconnects (accept all TPM fuse amp ratings)
|Catalog no.|Description|
|---|---|
|TPMDS-E|Pullout fused disconnect, English hardware|
|TPMDS-M|Pullout fused disconnect, metric hardware|
Dimensions — see data sheet no. 5022
Data sheet no. 5022
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
14-3
**14 — Telecom protection products**
## TP15900-4 fused pullout disconnect for TPA fuses
4-pole fused pullout disconnect for use with Telpower TPA and TPA-B fuses. Pullout disconnects feature remote open fuse indication capability.
## Ratings
## TP15914 fused pullout disconnect
Modular 4-pole fused pullout disconnect for us with TPA fuses. 4-poles per module can be ganged up to four modules for a total of 16 poles. The TP15914 features open fuse indication and fuse presence indication along with fuse orientation rejection.
- Volts
- 145 Vdc@40 A per pole
- 80 Vdc@50 A per pole
## Ratings
- Volts 145 Vdc
- Amps 50 A max per pole
## Agency information
- UL Recognized File E97649 as a disconnect switch for interruption of load current by means of withdrawing the fuse carrier
- UL Recognized as a component for telecommunication power distribution equipment (UL category QPQY2)
- UL Recognized fuses for branch circuit protection
- CSA Component Acceptance for the system
> • CE
## Typical applications
- Telecommunications DC power circuit protection
## Features
- Easy installation, connects directly to busbar, reduces external wiring per pole. Rear accessibility for line and load terminations
- LED alarm signaling (LED current 30 mA max)
- Local and remote open-fuse indication along with fuse orientation rejection feature and fuse presence indication
- Alarm test probe point allows on-site alarm circuit checking
|Catalog no.<br>TP15900-4|Description<br>4-pole common disconnect|||
|---|---|---|---|
|TP15900-41|4-pole common disconnect w/ split alarm, split line||4-pole common disconnect w/ split alarm, split line|
|Available fuses||||
|Catalog symbol|Amps|Volts DC|IR|
|TPA|3, 5, 10, 15, 20, 25, 30, 40, 50|170|100 kA|
|TPA-B|20, 25, 30|65|20 kA|
## Available fuses
## Accessories
## Agency information
- UL Recognized, Guide JFHR2, File E56412
- UL Recognized as a disconnect switch for interruption of load current by means of withdrawing the fuse carrier
- UL Recognized as a component for telecommunication power distribution equipment (UL category QPQYZ)
- UL Recognized fuses for branch circuit protection
- CSA Certified, Class 1422-30, File 53787
- CSA Component Acceptance for the system
## Typical applications
- Telecommunications DC power circuit protection
## Features
- Easy installation with totally enclosed module that connects directly to busbar to reduce external per-pole wiring.
- Standard front access load and line double lug connection for 8 AWG wire
- LED alarm signaling (LED current 30 mA max)
- Remote alarm with alarm test probe point to allow on-site alarm circuit checking
|Catalog no.|Description|
|---|---|
|TP15914|English hardware|
|TP15914-1|Metric hardware|
## Accessories
- Spare fuse holders: catalog numbers 5TPH and TPSFH-AS
## Dimensions — mm (in)
- Spare fuse holders: catalog numbers 5TPH and TPSFH-AS
## Dimensions — mm (in)
**==> picture [238 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
(10 - 32 Thread) a 0.745 ‘8 91<br>Fy _——— Mt<br>0.284<br>Po--0| —- JOUNTING —_<br>_ | oon fn pg<br>1.5 ed 1.5<br>awl Le © Tat HOHq OA OE<br>a 4 H] -<br>COMM<br>PTO<br>(rs jv ¥ ETOfp 5=)fofa)4<br>MOUNTINGHOLE DIA 0.215 oaBS 0.625 eeO-res ©arr90.58 3.57 a{_3E13}108.48 4.27 5p . tn OS uiI 76.073.0 ai<br>**----- End of picture text -----**<br>
Data sheet no. 5001
Data sheet no. 5011
Eaton.com/bussmannseries
14-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Telecom protection products — 14**
## TPA and TPA-B indicating fuses
Indicating DC power distribution fuse for use in TP15900-4 and TP15914 fused pullout disconnects.
## Ratings
- Volts
- 170 Vdc (TPA)
- 65 Vdc (TPA-B)
- Amps
- 3-50 A (TPA)
- 20-30 A (TPA-B)
**==> picture [37 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
## 15800 fused pullout disconnect for the TPS fuse
Fused pullout disconnect switch for use only with the TPS main fuses (1 to 70 amp) and GMT-A indicating fuse (see page 14-11). It is recommend to also use the GMT-X cover for the GMT-A fuse.
## Ratings
- Volts 60 Vdc
- Amps 3-70 A
- SCCR 100 kA
- IR
- 100 kA (TPA)
- 20 kA (TPA-B)
## Agency information
- UL Recognized, Guide JFHR2, File E56412
- CSA Certified, Class 1422-30, File 53787
- CE, RoHS compliant
## Typical applications
## Agency information
- UL Recognized, Guide QPQY2, File E97649
- CE
## Typical applications
- Telecommunications DC power circuit protection
## Features
- Alarm output with wire wrap terminal or connection to 0.063” thick common alarm bus
- Telecommunications DC power circuit protection
- Spare alarm and power fuse compartment
## Features
- Indication pin provides for local and remote indication when used with Bussmann series TP15900-4 and TP15914 disconnect switches
- Patented “orange ring” fuse orientation features assures correct fuse position
- The UL Recognized ratings and current-limiting capability make this fuse ideal for cable protection on existing DC power distribution systems
- A unique blue label is used on all Telpower fuses to designate their DC capability
|Catalog no. (amps)<br>170 Vdc<br>TPA-3<br>TPA-10<br>TPA-5<br>TPA-15<br>65 Vdc<br>TPA-B-20<br>TPA-B-25<br>~~OT~~<br>~~TOT~~<br>~~TTT~~|TPA-20<br>TPA-30<br>TPA-50<br>TPA-25<br>TPA-40<br>TPA-B-30|
|---|---|
- Mounting hardware included
|Catalog no.<br>15800-R-200<br>15800-F-200|Description<br>Rear access panel mounting<br>Front access panel mounting|
|---|---|
## Accessories
- Spare fuse holders: catalog numbers TPSFH-AS (TPS fuses) and TPSFH-T (GMT fuses)
Dimensions — in (mm)
**==> picture [17 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
72 lb-in<br>**----- End of picture text -----**<br>
## Accessories
- Spare fuse holders: 5 position holder; 5TPH; 6 position holder; TPSFH-AS
Dimensions — in (mm)
1.5 0.58 (38) (14.6) [1 _ 0.41 ~~[AF~~ (10.3)
Data sheet no. 5012
Data sheet no. 5002
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
14-5
- **14 — Telecom protection products**
- ~~7~~
## TPS main power fuse
## TP158HC fused pullout disconnect
Non-indicating DC power distribution ferrule fuses specifically designed to meet the unique needs of DC power distribution systems. For use with Bussmann series 15800 fused pullout disconnect. Vertical and horizontal PCB tab versions available for circuit board applications.
## Ratings
High amp panel mount, rear access fused pullout disconnect for use only with Telpower TPL-B main fuses (70-250 A) and GMT-A indicating fuse (see page 14-11). It is recommend to also use the GMT-X cover for the GMT-A fuse.
- Volts 170 Vdc
- Amps 1-80 A
- IR 100 kA
## Ratings
- Volts 80 Vdc
**==> picture [23 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
## Agency information
- Amps 70-250 A
- SCCR 100 kA
- UL Recognized, Guide JFHR2, File E56412, RoHS compliant, CE
## Agency information
## Typical applications
- Telecommunications DC power circuit protection
- Applications requiring printed circuit board mounting
## Features
- The UL Recognized ratings and current-limiting capability make this fuse ideal for cable protection on existing DC power distribution systems
- A unique blue label is used on all Telpower fuses to designate their DC capability
- PCB tab versions eliminate the need for fuseclips when mounting the fuse on a circuit board
**==> picture [231 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|Catalog no. (amps)|
|Ferrule|
|TPS-1|TPS-6|TPS-25|TPS-50|
|TPS-2|TPS-10|TPS-30|TPS-60|
|TPS-3|TPS-15|TPS-35|TPS-70|
|TPS-5|TPS-20|TPS-40|TPS-80|
|Horizontal PCB tabs|
|TPS-1L|TPS-6L|TPS-25L|TPS-50L|
|TPS-2L|TPS-10L|TPS-30L|TPS-60L|
|TPS-3L|TPS-15L|TPS-35L|TPS-70L|
|TPS-5L|TPS-20L|TPS-40L|TPS-70LB*|
|Vertical PCB tabs|
|TPS-40V|TPS-50V|TPS-80V|
**----- End of picture text -----**<br>
* LB = Bolt tag
## Accessories
- Spare fuse holder TPSFH-AS, see page 15-4
## Dimensions — in (mm)
**==> picture [80 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.88 0.56<br>(22) (14)<br>**----- End of picture text -----**<br>
- UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout, Guide QPQY2, File E97649
## Typical applications
- Telecommunications DC power circuit protection
## Features
- Similar profile, mounting method, and backplane configuration as 15800. The TP158HC can be installed into existing 15800 panels using the space of two 15800 pullout disconnects
- Innovative new fuse pullout design eliminates need for tools to replace the Telpower type TPL-B fuse
- Alarm output with wire wrap terminal or connection to 0.063 inch (1.6mm) thick common alarm bus
- Hardware included: Load: washer, split lockwasher, and 5/16 - 18 nut (metric M8 x 1.25)
**==> picture [181 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Catalog no.|Hardware type|
|TP158HC|English|
|TP158HC-M|Metric|
**----- End of picture text -----**<br>
## Accessories
- Spare fuse holders: TPSFH-LB (TPL-B fuses) and TPSFH-T (GMT fuses)
## Dimensions
- See data sheet no. 5021
## Application notes
The line connection uses a 1/4-20 bolt (metric M6 x 1) that threads into the line terminal. The line terminal is designed with a float of ±0.02" (±0.50mm) to allow for variation in the distance between the TP158HC mounting flange and the line busbar (see dimensions). Equipment should be designed to eliminate any relative movement between the TP158HC mounting flange and the line busbar.
The alarm circuit is not intended for pre-charging capacitive circuits. Maximum alarm circuit current 1 A.
Data sheet no. 5009
Data sheet no. 5021
Eaton.com/bussmannseries
14-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Telecom protection products — 14**
## 15100 fused pullout disconnect
## TPHCS high current fused pullout disconnect
Fused pullout disconnect system for use with TPL Telpower fuses.
## Ratings
- Volts 60 Vdc
- Amps 70-800 A
High current fused pullout disconnect for use with TPL-B, TPL-C and TPH Telpower fuses. Available as a complete pullout disconnect or just the pullout. Base may be purchased separately.
## Ratings
- SCCR 100 kA
- Volts 80 Vdc
Agency information
- UL Recognized, Guide QPQY2, File E97649
> • CE
## Typical applications
- Telecommunications DC power circuit protection
## Features
- Single-pole fusible disconnect switch for primary DC power distribution
- Robust housing and terminal construction for demanding applications
- Amps 70-800 A
- SCCR 100 kA
## Agency information
- UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse carrier
- UL Recognized to meet the requirements for Canadian TPHCS800-MAV shown Standards
Typical applications
- Panel mounting
> • Easily connected to line or load bus
- Telecommunications DC power circuit protection
## Features
~~|~~ Catalog no. TPL fuse amp range 15100-401 70-400 15100-601 300-800
- Innovative design eliminates needing tools to replace the TPL-B, TPL-C or TPH fuses
- Easy to install with captive fasteners for direct busbar mounting (bolts not included). Standard 1/4” quick-connect for easy remote alarm connection
Dimensions — in (mm)
- Optional electronic alarm eliminates needing parallel indicating fuses while providing local and remote open-fuse indication (maximum remote alarm current: 20 mA); Bipolar alarm: designed for both central office and Radio applications, Local LED open fuse indication for easy viewing.
**==> picture [268 x 293] intentionally omitted <==**
**----- Start of picture text -----**<br>
(171.45)6 [.75]<br>__<br>=<br>| ~ 4 | | 3 4<br>(76.2) (101.6) •<br>«_)|| • cabinets<br>0.27 (6.75) dia. hole with 0.5 dia. x 0.16 (3.97) deep C'bore (4 holes)<br>5.75<br>(146.05)<br>—<br>| —. |<br>3.63<br>(92.07)<br>2.75<br>(69.85)<br>7.13<br>(181.10)<br>cp cst<br>1.31 2.63<br>(33.33) (66.67)<br>ae<br>5.25<br>(133.35)<br>**----- End of picture text -----**<br>
- Carrier window allows easy viewing of installed fuse amp rating
- Compact design is ideal for today’s high power, high-density cabinets
|Catalog no.<br>(pullout and base)<br>Hardware<br>(option)<br>For fuse<br>symbol<br>Fuse amp<br>range<br>TPHCS250-M<br>Metric<br>TPL-B<br>70-250<br>~~bs~~|Catalog no.<br>(pullout and base)<br>Hardware<br>(option)<br>For fuse<br>symbol<br>Fuse amp<br>range<br>TPHCS250-M<br>Metric<br>TPL-B<br>70-250<br>~~bs~~|Catalog no.<br>(pullout and base)<br>Hardware<br>(option)<br>For fuse<br>symbol<br>Fuse amp<br>range<br>TPHCS250-M<br>Metric<br>TPL-B<br>70-250<br>~~bs~~|Catalog no.<br>(pullout and base)<br>Hardware<br>(option)<br>For fuse<br>symbol<br>Fuse amp<br>range<br>TPHCS250-M<br>Metric<br>TPL-B<br>70-250<br>~~bs~~|
|---|---|---|---|
|TPHCS250-E|English|TPL-B|70-250|
|TPHCS250-ML|Metric, LED|TPL-B|70-250|
|TPHCS250-EL|English, LED|TPL-B|70-250|
|TPHCS250-MAV|Metric, alarm|TPL-B|70-250|
|TPHCS250-EAV|English, alarm|TPL-B|70-250|
|TPHCS800-M|Metric|TPL-C or TPH|300-800|
|TPHCS800-E|English|TPL-C or TPH|300-800|
|TPHCS800-ML<br>Metric, LED<br>TPL-C or TPH<br>300-800<br>TPHCS800-EL<br>English, LED<br>TPL-C or TPH<br>300-800<br>~~OO~~||||
|TPHCS800-MAV<br>TPHCS800-EAV|Metric, alarm<br>English, alarm|TPL-C or TPH<br>TPL-C or TPH|300-800<br>300-800|
Data sheet no. 5003
Data sheet no. 5020
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
14-7
## **14 — Telecom protection products**
||Catalog no.<br>(components)<br>TPHCS250-P|Description rating/<br>hardware/option<br>Pullout only (250 A)|For fuse<br>symbol<br>TPL-B|Amp<br>range<br>70-250|
|---|---|---|---|---|
||TPHCS800-P|Pullout only (800 A)|TPL-C or TPH|300-800|
||TPHCS-B-M<br>TPHCS-B-E|Base only, metric<br>Base only, English|—<br>—|800 max<br>800 max|
|TPHCS-B-ML<br>Base only, metric, LED<br>~~OE~~|||—|800 max|
||TPHCS-B-EL|Base only, English, LED|—|800 max|
||TPHCS-B-MAV|Base only, metric, alarm|—|800 max|
||TPHCS-B-EAV|Base only, English,<br>alarm|—|800 max|
## Notes
1. TPHCS250 and TPHCS800 pullouts and bases are the same with exception to the fuse type the pullout will hold (TPL-B, TPL-C or TPH).
2. Plastic rated UL 94V0, 140ºC RTI.
## Dimensions — mm (in)
## TPL high amp DC fuses
High amp DC power distribution fuses for use with Telpower 15100, 15200, TP158HC and TPHCS fused pullout disconnects. TPL-TA adapter kit is necessary when replacing a UBO fuse.
## Ratings
- Volts 170 Vdc
- Amps 70-800 A
- IR 100 kA
## Agency information
- UL Recognized Guide JFHR2, File E56412 Bellcore
> • CE
## Typical applications
- Telecommunications power circuit protection
## Features
- Current-limiting design for DC power distribution systems
- UL Recognized branch circuit protection
- Complete system coordination capability
- Energy savings with low watts loss, low operating temperatures, and minimum I[2] t levels
|Catalog no.<br>Amps|Catalog no.<br>Amps|
|---|---|
|TPL-BA<br>70|TPL-BL<br>250|
|TPL-BB<br>80|TPL-CN<br>300|
|TPL-BC<br>90|TPL-CO<br>350|
|TPL-BD<br>100|TPL-CR<br>400|
|TPL-BE<br>125|TPL-CU<br>450|
|TPL-BF<br>150|TPL-CV<br>500|
|TPL-BG<br>175|TPL-CZ<br>600|
|TPL-BH<br>200|TPL-CZH<br>800|
|TPL-BK<br>225||
## Accessories
- Spare fuse holders: TPSFH-LB (for TPL-B fuses) TPSFH-LC (for TPL-C fuses)
Dimensions — in (mm)
**==> picture [150 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.66 (68)<br>2.19 (56)<br>1.161.91 (48)(29) 1.0 (25)<br>Ht O A<br>| LH 0.75 [(19)]<br>= ©)<br>rt | ha<br>0.33(8) 0.19 (5)<br>TPL-BA, TPL-BD, TPL-BF, TPL-BH, TPL-BK and TPL-BL<br>3.50 (89)<br>2.441.25 [(62)][(32)] 1.50 (38)<br>It | | ,<br>1.0 (25)<br>0.41(10)<br>TPL-CN, TPL-CR, TPL-CV and TPL-CZ 0.25 (6)<br>**----- End of picture text -----**<br>
Data sheet no. 5020
Data sheet no. 5005
Eaton.com/bussmannseries
14-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Telecom protection products — 14**
## TPN high amp current limiting DC fuses
Dimensions — in (mm)
**==> picture [45 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.56<br>2 (14)<br>(51)<br>**----- End of picture text -----**<br>
The TPN fuse is a currentlimiting DC power distribution fuse that’s dimensionally similar to UL Class R branch circuit fuses making them easy to install using standard RM60_ modular Class R fuse blocks.
Up to 30 A
**==> picture [94 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
3<br>(76)<br>0.81<br>ODT (21)<br>35 A to 60 A<br>**----- End of picture text -----**<br>
## Ratings
- Volts 170 Vdc
- Amps 1-600 A
- IR 100 kA
**==> picture [225 x 259] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.88<br>(149)<br>ee<br>1.06<br>(27)<br>m L Tyo<br>70A to 100A<br>7.13<br>(181)<br>ee<br>1.56<br>(38)<br>AL I [vot<br>110A to 200A<br>8.63<br>(219)<br>2.38<br>(60)<br>nt<br>225A to 400A<br>10.38<br>(264)<br>i =—— 2.88<br>(73)<br>**----- End of picture text -----**<br>
## Agency information
- UL Recognized, Guide JFHR2, File E56412
## Typical applications
- Telecommunications power circuit protection
Features
- Current-limiting design for DC power distribution systems
- Recognized branch circuit protection
- Complete system coordination capability
- Energy savings with low watts loss, low operating temperatures, and minimum I[2] t levels
## Catalog no. (amps)
|• Recognized branch circuit protection<br>• Complete system coordination capability<br>• Energy savings with low watts loss, low operating temperatures,<br>and minimum I[2]t levels<br>Catalog no. (amps)|• Recognized branch circuit protection<br>• Complete system coordination capability<br>• Energy savings with low watts loss, low operating temperatures,<br>and minimum I[2]t levels<br>Catalog no. (amps)|• Recognized branch circuit protection<br>• Complete system coordination capability<br>• Energy savings with low watts loss, low operating temperatures,<br>and minimum I[2]t levels<br>Catalog no. (amps)|• Recognized branch circuit protection<br>• Complete system coordination capability<br>• Energy savings with low watts loss, low operating temperatures,<br>and minimum I[2]t levels<br>Catalog no. (amps)|225A to 400A<br>~~nt~~|
|---|---|---|---|---|
|TPN-1<br>TPN-30<br>TPN-90<br>TPN-250<br>TPN-3<br>TPN-35<br>TPN-100<br>TPN-300<br>TPN-5<br>TPN-40<br>TPN-110<br>TPN-350<br>TPN-6<br>TPN-45<br>TPN-125<br>TPN-400<br>~~ee~~||||i|
|TPN-10|TPN-50|TPN-150|TPN-450||
|TPN-15|TPN-60|TPN-175|TPN-500|450A to 600A|
|TPN-20|TPN-70|TPN-200|TPN-600||
|TPN-25|TPN-80|TPN-225|||
**==> picture [60 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
450A to 600A<br>**----- End of picture text -----**<br>
Accessories
- Spare fuse holders:TPSFH-N30 (for TPN 1-30) TPSFH-N60 (for TPN 35-60)
Recommended modular* Class R fuse blocks
|Catalog no.<br>Amps<br>~~OO~~|Catalog no.<br>Amps<br>~~OO~~|
|---|---|
|RM25030-1CR|30|
|RM25060-1CR|60|
|RM25100-1CR|100|
|RM25200-1CR|200|
|RM25400-1CR|400|
|RM25600-1CR|600|
- Blocks can be snapped together to create the number of required poles. Optional indicating and non-indicating finger-safe covers available for all blocks.
Data sheet no. 5006
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
14-9
**14 — Telecom protection products**
## 70 Type pin indicating fuses
Pin indicating fuse for use in the 15087 panel-mount fuse holder.
## Ratings
- Volts
- 125 Vac
- 300 Vdc
## 15087 fuse holder
Panel mount fuse holder for use with 70 Type fuses.
## Ratings
- Volts 300 Vdc
- Amps 12 A
Agency information
- Amps 1/10-10 A
- IR 1 kA @ 300 Vdc
> • UL Recognized, Guide IZLT2, File E14853
> • CE
## Agency information
Flammability rating
- UL Recognized, Guide JDYX2, File E19180 Bellcore
## • CE
- UL 94V0
Catalog number 15087
||Catalog no.<br>(amps)<br>70P-1/10A*|Color code<br>Gray/White|Lucent comcode<br>ref. no.<br>100203413|Code/list no.<br>KS23751-L10|
|---|---|---|---|---|
||70R-15/100A*|Red/White|101384550|KS23751-L11|
||70E-18/100A*|Yellow|100203363|KS23751-L5|
||70X-2/10A|Black|—|—|
||70F-1/4A*|Violet|100203371|KS23751-L6|
||70K-1/4A*|Violet/White|100203405|KS23751-L9|
||70G-1/2A*|Red|100203389|KS23751-L7|
||70H-3/4A*|Brown|100203397|KS23751-L8|
|70I-1A<br>Pink<br>—<br>70A-1-1/3A*†<br>White<br>100203322<br>70B-2A*<br>Orange<br>100203330<br>70C-3A*<br>Blue<br>100203348<br>~~————~~||||—<br>KS23751-L1<br>KS23751-L2<br>KS23751-L3|
||70J-3-1/2A|Black/White|—|—|
||70D-5A*<br>70L-6A|Grn/Black<br>Grn/White|100203355<br>—|KS23751-L4<br>—|
||70M-8A|Brown/White|—|—|
||70N-10A|Violet/Yellow|—|—|
||72A Plastic Case (dummy)|72A Plastic Case (dummy)|100203421|—|
||72B Blister Pack (dummy)|72B Blister Pack (dummy)|103757977|—|
* Product designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1, December 1988.
- Not UL Recognized.
## Typical applications
- Telecommunications DC power circuit protection
## Features
- Panel mount fuse holder for 70 type fuses supplied with two screws
- Remote alarm capability
## Optional color-code eyelets
Color-coded eyelets are used with the fuse holder to indicate its fuse amp rating.
|Catalog no.|Amps|Color coding|
|---|---|---|
|1A1706-17|15/100|Red/White|
|1A1706-01|18/100|Yellow|
|1A1706-15|1/10|Gray/White|
|1A1706-02|2/10|Black|
|1A1706-03|1/4|Violet|
|1A1706-04|1/4|Violet/White|
|1A1706-05|1/2|Red|
|1A1706-06|3/4|Brown|
|1A1706-07|1|Pink|
|1A1706-08|1-1/3|White|
|1A1706-09|2|Orange|
|1A1706-10|3|Blue|
|1A1706-16|3-1/2|Black/White|
|1A1706-11|5|Green/Black|
|1A1706-12|6|Green/White|
|1A1706-13|8|Brown/White|
|1A1706-14|10|Violet/Yellow|
Data sheet no. 5007
Data sheet no. 5007
Eaton.com/bussmannseries
14-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Telecom protection products — 14**
## HLS, HLT, PCT holders for GMT indicating fuses
Configurable fuse holders for use with GMT indicating fuses:
- PCT single-pole
- HLS 1-25 pole without flanges
- HLT 1-25 pole with flanges
## Ratings
- Volts 60 Vdc/125 Vac
- Amps 15 A per pole
- Poles Up to 25 (HLT, HLS)
Agency information
- UL Recognized, Guide IZLT2, File E14853, 15 A (60 Vdc)
- CE
## Flammability rating
- UL 94V0
## Typical applications
- Telecommunications DC power circuit protection
## Features
- Multiple configurations provide application flexibility
- Compact size saves space
|Catalog symbol<br>PCT|Catalog symbol<br>Number of poles<br>1|Number of poles|
|---|---|---|
|HLS|1-25||
|HLT|1-25||
To order, see data sheet no. 5010 for build-a-code to determine:
- Body style (HLT or HLS)
- Number of poles
- Busbar type
- Busbar position
- Termination location
## GMT indicating fuses for HLS, HLT, PCT holders
Fast-acting indicating fuses for HLT, HLS and PCT fuse holders.
## Ratings
- Volts
**==> picture [23 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- 60 Vdc
- 125 Vac
**==> picture [49 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
GMT - Dummy<br>**----- End of picture text -----**<br>
- Amps 18/100 to 15 A
- IR
- 450 A@60 Vdc
- 300 A@125 Vac
## Agency information
- UL Recognized, Guide JFHR2, File E56412
- RoHS compliant, CE
## Typical applications
- Telecommunications DC power circuit protection
## Features
- Local and remote indication capability
- Color coded for easy amp rating identification
|Catalog no.<br>(amps)*<br>GMT-18/100A<br>GMT-1/4A<br>GMT-3/8A|Color code<br>Yellow<br>Violet<br>Green/Gray|Catalog no.<br>(amps)<br>GMT-3-1/2A<br>GMT-4A<br>GMT-5A|Color code<br>White/Blue<br>White/Brown<br>Green|
|---|---|---|---|
|GMT-1/2A|Red|GMT-7-1/2A|Black/White|
|GMT-65/100A|Black|GMT-10A|Red/White|
|GMT-3/4A|Brown|GMT-12A|Yellow/Green|
|GMT-1A|Gray|GMT-15A|Red/Blue|
|GMT-1-1/3A|White|GMT-Dummy|Gray body|
|GMT-1-1/2A|White/Yellow|GMT-X|Clear cover|
|GMT-2A|Orange|GMT-Y|Clear cover w/tab|
|GMT-3A|Blue|||
* Some GMT ratings may be sold only in bulk pack.
Data sheet no. 5010
## Accessories
- Spare fuse holder, catalog number TPSFH-T
## GMT-A fast-acting, open fuse indicator
Fast-acting GMT-A open fuse indicator is designed specifically for use in the Telpower 15800 and TP158HC fused pullout disconnects as a means of providing main fuse open indication.
## Agency information
**==> picture [23 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
2011/65/EU<br>**----- End of picture text -----**<br>
- UL Recognized, Guide JFHR2, File E56412
- RoHS compliant
- CE
## Catalog no./color code: GMT-A/Yellow
Data sheet no. 5008
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
14-11
**==> picture [144 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
BUSSMANN<br>SERIES<br>**----- End of picture text -----**<br>
## Selective coordination has never been easier.
With the Bussmann[TM] series Quik-Spec™ Coordination Panelboard (QSCP), it’s simple and cost-effective to selectively coordinate using published circuit breaker/fuse and fuse/fuse ratio tables.
What’s more, the compact panelboard features a footprint equal to circuit breaker panels but 40% smaller than traditional fusible panels. Its safetyfocused design includes finger-safe branches, branch fuse interlock and fuse ampacity rejection.
And with up to 200 kA short-circuit current rating (SCCR), the QSCP easily withstands high fault currents.
Learn more at Eaton.com/bussmannseries.
Follow us on social media to get the latest product and support information.
**Accessories — 15**
## Contents
Bussmann series accessories to fi t your needs
|Description|Section<br>page|
|---|---|
|SAMI™ fuse covers — Class CC, G, H(K), J, R, T and UL||
|supplemental (midget)<br>Fuse reducers — Class J, H(K) and R<br>Dummy fuse "neutrals" — 1/4" x 1-1/4", UL supplemental<br>(midget), Class CC, H(K) and R|2|
|Fuse pullers|3|
|Fuse testers||
|Spare fuse holders||
|Spare fuse cabinet||
||4|
|Tron™ clip clamps||
|DIN-Rail adapter||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
15-1
**15 — Accessories**
## SAMI™ fuse covers
SAMI (Safety And Maintenance Improvement) fuse covers help improve electrical safety by shielding a fuse that's mounted in an open style block. They are available in indicating and nonindicating versions for fuse Classes CC, G, H(K), J, RK1, RK5 and T, as well as UL supplemental (midgettype) fuses. Indicating feature requires a minimum of 90 V to illuminate lamp.
One cover required for each pole. WARNING: To avoid electrical shock, turn power off before installing, removing or servicing.
## Agency information
- UL Listed; SAMI-1I through SAMI-6I and SAMI-9I, SAMI-1N through SAMI-6N and SAMI-9N
- UL Recognized; Guide JDVS2, File E58836, SAMI-7I and SAMI-7N
## Fuse reducers and dummy “neutrals”
Reducers for Class J fuses (DFJ, JKS, LPJ)
Carton quantity: 10 pair
**==> picture [258 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Catalog no.|Fuse amp range|——|Equipment/block amps|
|J-63|1-30|60|
|J-13|1-30|100|
|J-16|35-60|100|
|J-26|35-60|200|[†]|
|J-21|70-100|200|[†]|
|J-41|70-100|400|[†]|
|J-42|[††]|110-200|400|[†]|
|J-62|110-200|600|[†]|
|J-64|225-400|600|[†]|
**----- End of picture text -----**<br>
† Not for bolt-on applications.
†† Not compatible with JKS fuses.
## Reducers for Class H(K) and R fuses
- CSA Certified, Class 6225-01, File LR47235
## Agency information
- CE
- UL Listed, Guide IZZR, File E12853
## Features
- CSA Certified, Class 6225-01, File 47235
- Insulated cover isolate fuses mounted in open blocks
Carton quantity: 10 pair
- Optional open fuse indicating light aids in system troubleshooting
- Units are re-usable
**==> picture [532 x 324] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Catalog no.|
|Allows visual marking of lineside and loadside of fuses|250 V|600 V|Fuse amp range|Equip./block amps|
|Class R reducers (FRN-R, FRS-R, KTN-R, KTS-R, LPN-RK, LPS-RK)|
|TEST PROBE|TEST PROBE|B|NO.263-R|NO.663-R|Up to 30|60|
|—|—|—|——|———|———————<—|NO.213-R|NO.216-R|Up to 30|100|
|A|C|NO.216-R|NO.616-R|35-60|100|
|Sj|
|NO.226-R|NO.626-R|35-60|200|
|NO.2621-R|[†]|NO.2621-R|[†]|70-100|200|
|OO|
|FUSE|NO.2641-R|[†]|NO.2641-R|[†]|70-100|400|
|NO.242-R|[†]|NO.642-R|[†]|110-200|400|
|NO.2661-R|[†]|NO.2661-R|[†]|70-100|600|
|Dimensions — in|
|Catalog|NO.2662-R|[†]|NO.2662-R|[†]|110-200|600|
|no.*|Volts/fuse class/amp range|A|B|C|NO.2664-R*|[†]|NO.2664-R*|[†]|225-400|600|
|600 V, J (0-30 A), 600 V, T (35-60 A)|
|SAMI-1N**|5.02|1.03|1.94|Class H(K) reducers (NON, NOS, REN, RES)|
|250 V, RK, K5, H (35-60 A)|NO.263|NO.663|Up to 30|60|
|SAMI-2_|600 V, RK, K5, H (0-30 A)|7.03|1.30|2.07|NO.213|NO.216|Up to 30|100|
|SAMI-3_|600 V, J (65-100 A)|7.03|1.30|2.33|NO.216|NO.616|35-60|100|
|SAMI-5_|600 V, RK, K5, H (35-60 A)|8.20|1.30|2.18|NO.226|NO.626|35-60|200|
|SAMI-6_|600 V, J (35-60 A)|4.98|1.17|2.14|NO.2621|NO.2621|70-100|200|
|SAMI-7_|600 V, Midget, Class CC, G (0-30 A)|3.82|0.75|1.72|NO.2641|[†]|NO.2641|[†]|70-100|400|
|250 V, RK, K5, H (0-30 A)|NO.2642|NO.2642|110-200|400|
|SAMI-9_|3.82|0.75|1.72|
|600 V T (0-30 A)|NO.2661|[†]|NO.2661|[†]|70-100|600|
|* For indicating cover, add suffix “I”, for non-indicating cover, add suffix “N,”|NO.2662|[†]|NO.2662|[†]|110-200|600|
|example: SAMI-7I = Indicating, SAMI-7N = Non-indicating.|
|** Available only as non-indicating.|NO.2664|[†]|NO.2664|[†]|225-400|600|
**----- End of picture text -----**<br>
> • Allows visual marking of lineside and loadside of fuses
* For indicating cover, add suffix “I”, for non-indicating cover, add suffix “N,” example: SAMI-7I = Indicating, SAMI-7N = Non-indicating.
** Available only as non-indicating.
Trimming guides, no. 12041, 12042, 12043, 12045, 12046, 12049
* Single reducer only, pair not required.
- Not CSA Certified.
Data sheet no. 1204
Data Sheet: 1118
Eaton.com/bussmannseries
15-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
BTM
**Accessories — 15**
## Dummy fuse “neutrals”
## Fuse pullers
**==> picture [437 x 40] intentionally omitted <==**
**----- Start of picture text -----**<br>
FP-2 FP-3 FP-4 FP-6<br>NTN-R-60 NTN-R-200<br>**----- End of picture text -----**<br>
|CFP_<br>FP-A3<br>Note: These are not fuses<br>Catalog no.<br>Volts<br>Fuse equivalent<br>Dimension<br>Amp range<br>NNB<br>—<br>13/32" x 1-1/2"<br>—<br>NNB<br>NNB-R<br>~~——\~~t|CFP_<br>FP-A3<br>Note: These are not fuses<br>Catalog no.<br>Volts<br>Fuse equivalent<br>Dimension<br>Amp range<br>NNB<br>—<br>13/32" x 1-1/2"<br>—<br>NNB<br>NNB-R<br>~~——\~~t|CFP_<br>FP-A3<br>Note: These are not fuses<br>Catalog no.<br>Volts<br>Fuse equivalent<br>Dimension<br>Amp range<br>NNB<br>—<br>13/32" x 1-1/2"<br>—<br>NNB<br>NNB-R<br>~~——\~~t|CFP_<br>FP-A3<br>Note: These are not fuses<br>Catalog no.<br>Volts<br>Fuse equivalent<br>Dimension<br>Amp range<br>NNB<br>—<br>13/32" x 1-1/2"<br>—<br>NNB<br>NNB-R<br>~~——\~~t|CFP_<br>FP-A3<br>Note: These are not fuses<br>Catalog no.<br>Volts<br>Fuse equivalent<br>Dimension<br>Amp range<br>NNB<br>—<br>13/32" x 1-1/2"<br>—<br>NNB<br>NNB-R<br>~~——\~~t|CFP_<br>FP-A3<br>Note: These are not fuses<br>Catalog no.<br>Volts<br>Fuse equivalent<br>Dimension<br>Amp range<br>NNB<br>—<br>13/32" x 1-1/2"<br>—<br>NNB<br>NNB-R<br>~~——\~~t||
|---|---|---|---|---|---|---|
|NNB-R|—|Class CC|—||||
|NNC|—|1/4" x 1-1/4”|—||Fuse pullers are available in various sizes to help safely and easily||
|NTN-R-30|250|Class R/H|Up to 30||extract fuses from blocks and holders. They are only to be used<br>when the associated circuit has been de-energized.||
|NTN-R-60|250|Class R/H|35-60||||
|NTN-R-100|250|Class R/H|70-100||Catalog no.<br>Application||
|NTN-R-200|250|Class R/H|110-200||FP-2<br>13/32" to 13/16" diameter fuses||
|NTN-R-400|250|Class R/H|225-400||FP-3<br>1" to 1-3/4" diameter. fuses||
|NTN-R-600|250|Class R/H|450-600||FP-4<br>1-3/4" to 2-1/2" diameter. fuses||
|NTS-R-30|600|Class R/H|Up to 30||FP-6<br>Up to 60 A Class T fuses||
|NTS-R-60|600|Class R/H|35-60||FP-A3<br>Glass tube and ATC fuses||
|NTS-R-100|600|Class R/H|70-100||CFP-30<br>CUBEFuse up to 30 A||
|NTS-R-200|600|Class R/H|110-200||CFP-60<br>CUBEFuse 35-60 A||
|NTS-R-400|600|Class R/H|225-400||CFP-100<br>CUBEFuse 70-100 A||
|Fuse testers<br>Fuse testers for automotive<br>blade, and, glass tube and<br>ferrule fuses up to 1-7/8" length.<br>Probes slide to appropriate fuse<br>length. Batteries are included<br>FT-2<br>NTS-R-600<br>600<br>Class R/H<br>450-600<br>~~a~~||||||Accessories|
||||||and replaceable.<br>FT-3||
WARNING: DO NOT test fuses while they are in the fuse panel.
|Catalog no.|Catalog no.<br>Description|
|---|---|
|FT-2*|Glass tube and ferrule fuse tester|
|FT-3|Blade fuse tester|
* Replacement battery is Rayovac 364 or equivalent.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
15-3
**15 — Accessories**
## Spare fuse holders
TPSFH spare fuse holders are durably constructed using thermoplastic and feature common mounting using #6 screws or bolts on 5-inch centers. With built-in retaining clips to secure fuses, these dovetailed/interlocking holders simplify installation and reduce hardware needs. Common footprint allows for any combination of holders to be mounted together.
5TPH spare fuse holder for Class CC and 13/32" diameter fuses is constructed of thermoplastic with adhesive tape on back for easy mounting on cabinet doors without the need for extra hardware.
Flammability rating: UL 94V0
|Catalog no.<br>TPSFH-CW|Fuse capacity<br>4|For use with:<br>TPC and/or TPW fuses|
|---|---|---|
|TPSFH-M|4|TPM fuses|
|TPSFH-LC|1|TPL-C series fuses|
|TPSFH-LB|1|TPL-B series fuses|
|TPSFH-N60<br>TPSFH-N30|1<br>4|TPN (35-60 A) fuses<br>TPN (1-30 A) fuses|
|TPSFH-AS|6|TPA and TPS fuses|
|TPSFH-T|10|GMT fuses|
|5TPH|5|Class CC and 13/32" diameter fuses|
Data sheet no. 5014
## TRON™ clip clamps
Clip clamps are constructed with a phenolic knob and plated-steel jaws. They provide a means of tightening the contact between fuse block clips and the fuse and are available in various sizes for both ferrule and blade-type cartridge fuse clips.
|Catalog no.|Catalog no.<br>Volts<br>For fuse amps|
|---|---|
|NO.1|250<br>Up to 30|
||250<br>35-60|
|NO.2|600<br>Up to 30|
|NO.4|600<br>35-60|
|NO.5<br>NO.6|250/600<br>70-100<br>250/600<br>110-200|
|NO.7|250/600<br>225-400|
|NO.8|250/600<br>450-600|
## DIN rail adapter
A DIN-Rail adapter permits secure, positive snap-on mounting of up to 30 amps fuse blocks (1-, 2-, or 3-pole) onto various size rails to eliminates costly and time consuming drilling, tapping, and fastener mounting. The adapter mechanically locks into mounting holes of fuse blocks to form an integral part. One adapter is required for 1- and 2-pole blocks. Two adapters are required for 3-pole blocks.
With the exception of the 32mm DIN-Rail, all block/adapter assemblies can be removed from a rail simply by pulling up on the release tab.
Use of rail end-stops on both sides of adapters is recommended.
## Spare fuse cabinet
SFC locking spare fuse cabinet measures 24" W x 30" H x 12" D and has five cubic feet of storage space. It's constructed of heavy 16 gauge steel with durable baked ASA 61 grey enamel finish. Cabinet door is equipped with locking handle for security. Mounting holes are 16 inches on center with key slots.
|Catalog no.|Catalog no.<br>Block fuse class/size*<br>CC|Fits rail sizes|Color|
|---|---|---|---|
||13/32" x 1-1/2"|||
||10x38mm|15mm (Sym.)||
|DRA-1|G|32mm (Asym.)|Black|
||H (250 V)†|DIN 35mm (Sym.)||
||J (30 A, 60 A*)|||
||R (250 V)†|||
* Not applicable for new modular fuse blocks that have built-in 35mm DIN-Rail mount capability.
- Mounting on 15mm rails is not recommended.
|Catalog no.|Description|
|---|---|
|SFC-FUSE-CAB|Cabinet and one shelf|
|SFC-SHELF*|Extra shelf for cabinet|
|2A1910-1|Replacement key|
|2A1910-3|Replacement lock|
## Package quantities
- Standard 10
- Bulk 100 (Cat. No. BK/DRA-1)
Data sheet no. 1119
Eaton.com/bussmannseries
15-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse and fuse block cross reference, and index — 16**
## Contents
## We make what matters work*
|Description|Section<br>page|
|---|---|
|Fuse sizing for 600 V building electrical systems|2-3|
|Selective coordination|4|
|Low voltage, branch circuit fuse types and classes|5|
|Glossary of common electrical terms<br>Electrical formulas|6-7<br>7|
|FuseFinder fuse and fuse block cross reference|8-9|
|Catalog number index|10-14|
For information on products not contained in this catalog, contact Customer Satisfaction, toll-free, at 855-287-7626 (855-BUSSMANN) between 7:00 a.m. — 6:00 p.m. Central time, M-F, or email BussCustSat@Eaton.com.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
16-1
## **16 — Fuse and fuse block cross reference, and index**
## Fuse sizing for 600 V building electrical systems
General guidelines are given for selecting fuse amp ratings for most circuits. For specific applications warranting other fuse sizing, the load characteristics and appropriate NEC sections should be considered. The selections shown here are not, in all cases, the maximum or minimum amp ratings permitted by the NEC. Demand factors as permitted by the NEC are not included. Study the pertinent NEC sections noted by “()” and reference pertinent footnotes.
## **Recommended fuses:**
**==> picture [250 x 322] intentionally omitted <==**
**----- Start of picture text -----**<br>
• Low-Peak KRP-C Class L, time-delay, 601 to 6000 A<br>• Low-Peak 250 V LPN-RK/600 V LPS-RK Class RK1,<br> dual element, time-delay, up to 600 A<br>• Fusetron 250 V FRN-R/600 V FRS-R Class RK5,<br>1 dual element, time-delay, up to 600 A<br>Feeder Feeder Feeder<br>10 8 Fuse 2 with no 3 with all 4 with 11<br>> 600 A motor motor combo<br>load load motor/<br>Motor no motor<br>load<br>starter<br>overload<br>relay<br>6a 6b 7 12<br>Large<br>M motor<br>5 5 5 M M M<br>Cont. Non-<br>loads, cont.<br>lighting/ loads 7 7 7 5 5<br>heating<br>M M M<br>9 Continuous<br>loads<br>Power factor<br>correction<br>capacitor<br>**----- End of picture text -----**<br>
## Dual-element, time-delay fuses
Class CF (up to 400 A), and J, RK1 and RK5 ( up to 600 A)
For fuses above 600 A, use Class L time-delay fuses with ratings from 601-6000 A. While these fuses are not dual-element construction, the Bussmann series KRP-C-SP is a time-delay fuse.
1. Main service. Size fuse according to method in 4 below.
2. Feeder circuit with no motor loads. (215.3) The fuse size must be at least 125% of the continuous load† plus 100% of the non-continuous load. Do not size larger than the conductor’s ampacity*.
3. Feeder circuit with all motor loads. (430.62) Size the fuse at 150% to 175% of the largest motor’s full load current** plus the full-load current** of all other motor's∆.
4. Feeder circuit with mixed loads∆. (430.63) Size fuse at sum of:
- a. 150% to 175%†† of the largest motor’s full-load current**, plus
- b. 100% of all other motors’ full-load current**, plus
- c. 125% of the continuous, non-motor load†, plus
- d. 100% of the non-continuous, non-motor load
5. Branch circuit with no motor load. (210.20) The fuse size must be at least 125% of the continuous load† plus 100% of the non-continuous load. Do not size larger than the conductor’s ampacity*.
6. Motor branch circuit with overload relays. Where overload relays are sized per 430.32 for motor running overload protection, there are various alternatives:
- 6a. Motor branch circuit short-circuit and ground fault protection. (430.52) (most common). Size the fuse between 150 to 175%†† of the full load current.** Provides branch circuit short-circuit and ground fault protection only.
- 6b. Motor branch circuit short-circuit and ground fault protection (430.52) as well as backup overload protection. Size FRN-R and FRS-R Class RK5 dual-element, time-delay fuses at 125% and LPN-RK-SP and LPS-RK-SP Class RK1 dual-element, time-delay fuses at 130% of motor full-load current or next higher size. This results in closer fuse sizing and provides some backup running overload protection. In addition, it provides motor branch circuit shortcircuit and ground fault protection. Sizing in this manner may result in better motor protection if the overload relays are not properly sized or calibrated.
7. Motor branch circuit with only fuse protection. Where the fuse is the only motor protection, the following FRS-R and FRN-R, Class RK5, fuses provide motor running overload protection (430.32) and short-circuit protection (430.52):
- Motor 1.15 service factor or 40°C rise. Size the fuse at 110% to 125% of the motor full-load current on the name plate [430.6(a)(2)].
- Motor less than 1.15 service factor or over 40°C rise. Size fuse at 100% to 115% of motor full-load current on the name plate [430.6(a)(2)].
8. Large motor branch circuit. Fuse larger than 600 A. [436.52(c) and 430.52(c)(1) Exceptions 2(d)]. For large motors, size LowPeak KRP-C-SP time-delay fuse at 175% to 300% of the motor full-load current**, depending on the starting method; i.e., partwinding starting, reduced voltage starting, etc.
9. Power factor correction capacitors. [460.8(b)]. Size dualelement fuses as low as practical, typically 150% to 175% of capacitor rated current.
10. Transformer primary fuse (without secondary fuse protection). [450.3(b)] When transformer primary current is equal to or greater than 9 amps, the dual-element, time-delay fuse should be sized at 125% of transformer primary current or the next size larger if 125% does not correspond to a standard fuse size. Note: Secondary conductors must be protected from overcurrent damage per Article 240.
11. Transformer primary fuse (with secondary fuse protection). [450.3(b)] May be sized at 250% of transformer primary current if the secondary is fused per 12 below.
12. The secondary fuse is sized at no more than 125% of secondary full-load current. [450.3(b)] Note: Secondary conductors must be protected at their ampacities per Article 240.
16-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse and fuse block cross reference, and index — 16**
Non-time delay and all Class CC fuses
(FCF, JKS, KTN-R, KTS-R, JJN, JJS, LP-CC, KTK-R and FNQ-R)
1. Main service. Size fuse according to method in 4.
2. Feeder circuit with no motor loads. (215.3) The fuse size must be at least 125% of the continuous load† plus 100% of the non-continuous load. Do not size larger than the conductor’s ampacity.*
3. Feeder circuit with all motor loads. (430.62) Size the fuse at 300% of the largest motor’s full-load current** plus the full-load current** of all other motors.
4. Feeder circuit with mixed loads. (430.62) Size fuse at sum of:
- a. 300% of the full-load current** of the largest motor, plus
- b. 100% of the full-load current** of all other motors, plus
- c. 125% of the continuous, non-motor load†, plus
- d. 100% of the non-continuous, non-motor load
5. Branch circuit with no motor loads. (210.20) The fuse size must be at least 125% of the continuous load† plus 100% of the non-continuous load. Do not size larger than the conductor’s ampacity.*
- 6a. Motor branch circuit with overload relays. (430.52) Size the fuse at 300% of the full load current**. Provides branch circuit short-circuit and ground fault protection only. Other means must be utilized to provide motor overload protection (see 430.32). (If 300% is not a standard fuse amp rating, 430.52(C)(1) Exception 1 permits the next standard fuse amp rating. If the motor cannot start with this size fuse, 430.52(C) (1) Exception 2 permits increasing the fuse size up to 400% provided the fuse rating does not exceed 600 A.)
- 6b. Motor branch circuit short-circuit and ground fault protection (430.52) as well as backup overload protection. Not applicable for non-time-delay fuses; use FRN-R and FRS-R, Class RK5, dual-element time-delay fuses or LPN-RKSP and LPS-RK-SP Class RK1, dual-element, time-delay fuses (see 6b under dual-element time-delay fuse selection). Nontime-delay fuses cannot be sized close enough to provide motor running backup overload protection. If sized for motor overload backup protection, non-time-delay fuses would open due to motor starting current.
7. Motor branch circuit with only fuse protection. Not applicable for non-time-delay fuses; use FRN-R and FRS-R, Class RK5, dualelement time-delay fuses (see 7 under dual-element time-delay fuse selection). Non-time-delay fuses cannot be sized close enough to provide motor running overload protection. If sized for motor overload protection, non-time-delay fuses would open due to motor starting current.
8. Power factor correction capacitors. [460.8(B)] Size non-timedelay fuses as low as practical, typically 250% to 300% of capacitor rated current.
Conductor ampacity selection
1. Feeder circuit and main circuit with mixed loads. (430.24) conductor ampacity at least sum of:
3. Feeder circuit with all motor loads. (430.24) Conductor ampacity at least 125% of the largest motor full-load amps plus 100% of all other motors’ full-load amps.
4. Feeder circuit with mixed loads. (430.24) Size according to method 1 above.
5. Branch circuit with no motor load. [210.19(a)(10] Conductor ampacity at least 125% of the continuous load plus 100% of the non-continuous load.
- 6, 7 and 8. Motor branch circuits. (430.22) Conductor ampacity at least 125% of the motor full-load current.
9. Capacitor connected to motor branch circuit. (460.8) Conductor ampacity at least 135% of capacitor rated current, and at least 1/3 the motor circuit conductors’ ampacity.
- 10, 11. Conductor ampacity minimum 125% of transformer fullload current.
12. Conductor ampacity per 1 above.
- 100% of the continuous load can be used rather than 125% when the switch and fuse are listed for 100% continuous operation as an assembly (e.g., 215.3 Exc 1). Some bolted pressure switches and high pressure contact switches 400 A to 6000 A with Class J and L fuses in specified assemblies are listed for 100% continuous operation.
- Where conductor ampacity does not correspond to a standard fuse amp rating, the next higher amp rating fuse is permitted when 800 A or less [(240.4(B)]. Above 800 A the conductor ampacity must be equal or greater than the fuse amp rating [(240.4(C)]. However, per 240.91(B), when above 800 A for supervised industrial installations, the conductor ampacity is permitted to be 95% of the fuse amp rating as long as the equipment is listed for that size conductor and the conductor is protected within its time vs. current limits [240.4 Informational Note].
- ∆ In many motor feeder applications dual-element fuses can be sized at ampacity of feeder conductors.
- Available short-circuit current and the clearing time of the overcurrent device must be considered so that the conductor’s ICEA (P32.382) withstand rating is not exceeded.
- ** On general motor applications, motor full load amps for calculating conductor ampacity and for calculating fuse amp ratings for motor branch circuit shortcircuit and ground fault protection (430.52) are selected from NEC Tables 430.247 through 430.250 per 430.6(A)(1). However, the motor nameplate current rating is used for sizing motor overload protection (430.32) per 430.6(A)(2).
- †† 430.52(C)(1) allows a maximum of 175% for time-delay fuses, for all but wound rotor and DC motors. A range of 150% to 175% was used for these guidelines, even though 430.52(C)(1) allows a maximum of 175% for timedelay fuses as stated above. The reason for showing this range is to highlight the possibility for application selection. In some situations, there may be a difference in the switch amp rating or fuse block amp rating in selecting 150% versus 175%. Using 175% is permitted and is suggested for heavy starting current or longer starting time applications.
- Further note: the NEC permits larger sizing via two exceptions. 430.52(C) (1) Exception 1 permits the next standard size if 175% does not correspond with a standard fuse amp rating. If the motor cannot start with this size fuse, 430.52(C)(1) Exception 2 permits increasing a time-delay fuse size up to 225%.
- (Note that while a time-delay fuse may not exceed 225% when using Exception 2, using a time-delay fuse could exceed 225% when applying Exception 1. For example, assume a motor with a FLA of 1.0 amp. 430.52(C) (1) would allow a 1.75 amp fuse. Exception 1 would allow a 3 amp timedelay fuse per 240.6(A). Exception 2 limits the time-delay fuse to 2.25 amps as a maximum, but Exception 2 is not utilized or needed if Exception 1 is adequate.)
- *** The conductor ampacity may have to be greater due to using adjustment or correction factors per 210.(19)(A)(1) and 215.2(A)(1).
- a. 100%†† of the full-load current** of the largest motor, plus
- a. 100% of the full-load current** of all other motors, plus
- c. 125% of the continuous, non-motor load†, plus
- d. 100% of the non-continuous, non-motor load
2. Feeder circuit with no motor load. [215.2(a)(1)] Conductor ampacity at least 125% of the continuous load plus 100% of the non-continuous load.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
16-3
**16 — Fuse and fuse block cross reference, and index**
## Selective coordination
While important, selecting overcurrent protective devices (OCPDs) based solely on their ability to carry system load current and interrupting the maximum fault current at their respective application points is not enough. As the demand for power system reliability increases, the OCPD’s performance in the system becomes more and more critical as its function should, ideally, limit a power system outage to only that portion of the circuit which is faulted. The selected OCPD types and ratings (or settings) determine whether they are selectively coordinated upstream and downstream in a system so that only the nearest upstream OCPD will open for the full range of overcurrents and opening times, and leave the remainder of the system undisturbed to preserve service continuity.
**==> picture [220 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
X<br>LPS-RK-200SP<br>LPS-RK-400SP<br>KRP-C-800SP<br>2:1 (or more)<br>2:1 (or more)<br>**----- End of picture text -----**<br>
Figure 1 Low-Peak fuses applied with a simple 2:1 amp rating ratio achieves selective coordination.
Figure 1 shows the minimum amp rating ratios for Bussmann series Low-Peak fuses required to provide “selective coordination” (discrimination) between upstream and downstream fuses.
It’s a simple matter to selectively coordinate a system using published fuse amp rating ratio tables and maintaining the minimum ratios between an upstream and downstream fuse. This will ensure selective coordination is achieved for all fault currents up to the fuse’s interrupting rating. These selectivity ratios are for all overcurrent levels up to the fuse interrupting or 200 kA, whichever is lower.
For an in-depth examination of this subject, see selective coordination in Section 4 of the Selecting Protective Devices handbook, publication number 3002.
## Coordination, Selective (selective coordination)
Localization of an overcurrent condition to restrict outages to the circuit or equipment affected, accomplished by the selection and installation of overcurrent protective devices and their ratings or settings for the full range of available overcurrents, from overload to the maximum available fault current, and for the full range of overcurrent protective device opening times associated with those overcurrents.
Selective coordination is mandatory per the NEC for the circuit paths of some vital loads on specific systems including:
- Elevator circuits — 620.62
- Critical operations data systems — 645.27
- Campus style fire pumps — 695.3
- Emergency systems — 700.32
- Legally required standby systems — 701.27
- Critical operations power systems — 708.54
## Bussmann series fuse selectivity ratios
This selectivity ratio table identifies the fuse amp rating ratios that ensure selective coordination.
**==> picture [537 x 299] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuit Downstream / loadside fuse<br>Amp rating 601- 601- 601- 0- 0-<br>1-100 A 0-600 A 0-600 A 0-600 A 0-30 A<br>range 6000 A 4000 A 6000 A 1200 A 60 A<br>Fuse Time- Time- Fast- Fast- Fast- Fast- Time-<br>Time-delay Dual-element, time-delay<br>type delay delay acting acting acting acting delay<br>Trade name Low-Peak Limitron CUBEFuse Low-Peak Low-Peak Fusetron Limitron Limitron Limitron Limitron SC<br>(CC)<br>(fuse class) (L) (L) (CF [2] ) (J) (RK1) (RK5) (L) (RK1) (T) (J) (G)<br>Bussmann LP-CC<br>LPN-RK-SP FRN-R KTN-R JJN<br>fuse KRP-C_SP KLU TCF LPJ-SP KTU JKS SC FNQ-R<br>LPS-RK-SP FRS-R KTS-R JJS<br>symbol KTK-R<br>601 to Time- Low-Peak<br>KRP-C-SP 2:1 2.5:1 2:1 2:1 2:1 4:1 2:1 2:1 2:1 2:1 2:1 2:1<br>6000 A delay (L)<br>601 to Time- Limitron<br>KLU 2:1 2:1 2:1 2:1 2:1 4:1 2:1 2:1 2:1 2:1 2:1 2:1<br>4000 A delay (L)<br>0 to 600 A Dual- Low-Peak LPN-RK-SP — — 2:1 2:1 2:1 8:1 — 3:1 3:1 3:1 4:1 2:1<br>element (RK1) LPS-RK-SP<br>0 to 600 A Dual- Low-Peak LPJ-SP — — 2:1 2:1 2:1 8:1 — 3:1 3:1 3:1 4:1 2:1<br>element (J)<br>0 to 100 A Dual- CUBEFuse TCF — — 2:1 2:1 2:1 8:1 — 3:1 3:1 3:1 4:1 2:1<br>element (CF [2] )<br>0 to 600 A Dual- Fusetron FRN-R — — 1.5:1 1.5:1 1.5:1 2:1 — 1.5:1 1.5:1 1.5:1 1.5:1 2:1<br>element (RK5) FRS-R<br>601 to Fast- Limitron<br>KTU 2:1 2.5:1 3:1 3:1 3:1 6:1 2:1 2:1 2:1 2:1 2:1 2:1<br>6000 A acting (L)<br>0 to 600 A Fast- Limitron KTN-R — — 3:1 3:1 3:1 8:1 — 3:1 3:1 3:1 4:1 —<br>acting (RK1) KTS-R<br>0 to 1200 A Fast- Limitron JJN — — 3:1 3:1 3:1 8:1 — 3:1 3:1 3:1 4:1 —<br>acting (T) JJS<br>0 to 600 A Fast- Limitron JKS — — 3:1 3:1 3:1 8:1 — 3:1 3:1 3:1 4:1 —<br>acting (J)<br>0 to 60 A Time- SC SC — — 3:1 3:1 3:1 4:1 — 2:1 2:1 2:1 2:1 —<br>delay (G)<br>Upstream / lineside fuse<br>**----- End of picture text -----**<br>
General notes: Ratios given in this table apply to only Bussmann fuses. When fuses are within the same case size, consult Bussmann.
1. Where applicable, ratios are valid for indicating and non-indicating versions of the same fuse. At some values of fault current, specified ratios may be lowered to permit closer fuse sizing. Consult Bussmann.
2. Time-delay Class CF TCF CUBEFuse OCPDs are 1 to 100 A Class J performance; dimensions and construction are a unique, finger-safe design.
16-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse and fuse block cross reference, and index — 16**
Low voltage, branch circuit fuse types and classes
The NEC defines the branch circuit OCPD as capable of providing protection for service, feeder and branch circuits, and equipment over the full range of overcurrents between its rated current and its interrupting rating. They’re also the only OCPDs the NEC permits to be installed in a building’s electrical system. The definition found in Article 100 is as follows:
“Overcurrent Protective Device, Branch Circuit. A device capable of providing protection for service, feeder, and branch-circuits and equipment over the full-range of overcurrents between its rated current and its interrupting rating. Such devices are provided with interrupting ratings appropriate for the intended use but no less than 5,000 amperes.”
Per this definition, branch circuit OCPDs are suitable to protect branch or feeder circuits and service conductors at any point in the electrical system, and must be capable of protecting against the full range of overcurrents, including overloads and faults. In addition, the OCPD must have an interrupting rating sufficient for the application per NEC 110.9. Branch circuit OCPDs meet common, minimum standard requirements for spacing and operating time-current characteristics defined by UL.
For example, by using Class J fuses and equipment, only Class J fuses can be installed. This ensures the voltage rating is always 600 V (whether the system is 120, 208, 480, or 575 V), the interrupting rating is at least 200 kA, and the fault current protection provided by its current-limiting, let-through characteristics. If the fuse needs replacing, only a Class J fuse can be installed.
Class R rejection ferrule Class R fuse rejection clips (restriction on the ferrule or notch on the blade) that will only accept Class R fuses. Class R rejection blade
Common current-limiting Bussmann series fuses
The table below contains the acceptable fuses that can be used for branch circuit protection.
|Device type|Acceptable devices|Bussmann series fuses|||
|---|---|---|---|---|
||Class CC|LP-CC, FNQ-R, KTK-R|||
||Class CF|TCF, FCF|||
||Class G|SC|||
|UL 248 branch|Class H(K)<br>Class J|NON, NOS<br>LPJ-, JKS, DFJ|FRN-R — Class RK5, 250 V, 200 kA IR<br>up to 600 A|LPN-RK — Class RK1, 250 V, 300 kA IR<br>up to 600 A|
|circuit fuses|Class L|KRP-C, KLU, KTU|||
||Class RK1<br>Class RK5<br>Class T<br>Plugfuses|LPN-RK, LPS-RK, KTN-R,<br>KTS-R<br>FRN-R, FRS-R<br>JJN, JJS<br>W, T, TL, S, SL|wihat|at|
The UL 248 fuse standards cover distinct low-voltage (600 volts or less) fuse classes. Of these, modern current-limiting fuse Classes CC, CF, G, J, L, R and T are the most important. The branch circuit current-limiting fuses’ rejection feature helps ensure electrical system safety over its life because it prevents installing other fuse types or larger case sizes. Thus, fuses that cannot provide a comparable minimum protection level for critical ratings and performance cannot be inadvertently installed.
This is inherent in all current-limiting fuse classes. Each fuse class must meet:
- Maximum let-through limits (Ip and I[2] t) during fault conditions
- Minimum voltage ratings
- Minimum 200 kA interrupting ratings for Class CC, CF, J, L, R and T
- Physical rejection of
- Different fuse classes and case sizes*
- Non current-limiting fuses
- Branch circuit fuse blocks and holders are made to hold a fuse class case size that corresponds to a particular amp range. This prevents fuses from the same class with a larger case size from being installed and helps prevent overfusing. There are instances where it is desirable to install a class fuse with a smaller case size than the block or holder. For these situations, it is permitted to use fuse reducers.
These product standards ensure branch circuit fuses provide specific, minimum circuit protection when current-limiting fuses and equipment are used. A given fuse class will ensure the voltage and interrupting rating, and degree of current limitation for the electrical system’s life.
FRS-R — Class RK5, 600 V, 200 kA IR LPS-RK — Class RK1, 600 V, 300 kA IR up to 600 A up to 600 A anit? @::! LPJ — Class J, 600 V, 300 kA IR LP-CC, FRQ-R, KTK-R — Class CC, up to 600 A 600 V, 200 kA IR up to 30 A JJN — Class T, 300 V, 200 kA IR JJS — Class T, 600 V, 200 kA IR up to 1200 A up to 800 A
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
16-5
**16 — Fuse and fuse block cross reference, and index**
Glossary of common electrical terms
Ampere (amp) — The measurement of intensity of rate of flow of electrons in an electrical circuit. An amp is the amount of current that will flow through a resistance of one ohm under a pressure of one volt.
Amp rating — The current-carrying capacity of a fuse. When a fuse is subjected to a current above its amp rating, it will open the circuit after a predetermined period of time.
Amp squared seconds, l[2] t —The measure of heat energy developed within a circuit during the fuse’s clearing. It can be expressed as “Melting I[2] t”, “Arcing I[2] t” or the sum of them as “Clearing l[2] t”. “l” stands for effective let-through current (RMS), which is squared, and “t” stands for time of opening, in seconds.
Arcing time — The amount of time from the instant the fuse link has melted until the overcurrent is interrupted, or cleared.
Breaking capacity — (See Interrupting rating)
Cartridge fuse — A fuse consisting of a current responsive element inside a fuse tube with terminals on both ends.
Class CC fuse — 600 V, 200 kA amp interrupting rating, branch circuit fuses with overall dimensions of 13/32” x 1-1/2”. Their design incorporates a rejection feature that allows them to be inserted into rejection fuse holders and fuse blocks that reject all lower voltage, lower interrupting rat ing 13/32” x 1-1/2” fuses. They are available from 1/10 through 30 amps.
Class CF fuse — A finger-safe UL Listed branch circuit rated fuse. Available in time-delay or fast-acting versions, the Class CF fuse has Class J electrical performance and is available in ratings from 1 to 100 A in 30, 60 and 100 A case sizes.
Class G fuse — A size rejecting branch circuit fuse in ratings from 1/2 through 20 amps (600 Vac) and 25 through 60 amps (480 Vac) with a 100 kA interrupting rating. The size rejecting feature helps to eliminate overfusing. The fuse diameter is 13/32” while the length varies from 1-5/16” to 2-1/4”.
Class H fuse — 250 V and 600 V, 10 kA interrupting rating branch circuit fuses that may be renewable or non-renewable. These are available in ratings from 70 through 600 amps.
Class J fuse — These rejection style fuses are rated to interrupt a minimum of 200 kA AC. They are labeled as “current-limiting”, are rated for 600 Vac and are not interchangeable with other classes. They are available from 1 through 600 amps.
Class K fuses — These are fuses listed as K-1, K-5, or K-9 fuses. Each subclass has designated I[2] t and lp maximums. These are dimensionally the same as Class H fuses, and they can have interrupting ratings of 50 kA, 100 kA, or 200 kA. While these fuses are current-limiting, they are not marked “current-limiting” on their label since they do not have a rejection feature.
Class L fuse — These fuses are rated for 601 through 6000 amps, and are rated to interrupt a minimum of 200 kA AC. They are labeled “currentlimiting” and are rated for 600 Vac. They are intended to be bolted into their mountings and are not normally used in clips. Some Class L fuses have designed-in time-delay features for all purpose use.
Class R fuse — These are high performance fuses rated 1/10 through 600 amps in 250 V and 600 V ratings. All are marked “current-limiting” on their label and all have a minimum of 200 kA interrupting rating. They have identical outline dimensions with the Class H fuses but have a rejection feature that prevents the user from mounting a fuse of lesser capabilities (lower interrupting capacity) when used with special Class R Clips. Class R fuses will fit into either rejection or non-rejection clips.
Class T fuse — An industry class of 300 V and 600 V fuses in ratings from 1 through 1200 amps (300 V) and 1 through 800 amps (600 V). They are physically very small and can be applied where space is at a premium. They are fast-acting fuses, with an interrupting rating of 200 kA RMS.
Classes of fuses — The industry has developed basic physical specifications and electrical performance requirements for fuses with voltage ratings of 600 V or less. These are known as standards. If a type of fuse meets the requirements of a standard, it can fall into that class. Typical UL branch circuit fuse classes are CC, CF, G, H, J, K, L, RK1, RK5 and T.
Clearing time — The total time between the beginning of the overcurrent and the final opening of the circuit at rated voltage by an overcurrent protective device. Clearing time is the total of the melting time and the arcing time.
Current limitation — A fuse operation relating to short-circuits only. When a fuse operates in its current-limiting range, it will clear a shortcircuit in less than 1/2 cycle. Also, it will limit the instantaneous peak letthrough current to a value substantially less than that obtainable in the same circuit if that fuse were replaced with a solid conductor of equal impedance.
Dual-element fuse — A fuse with a special design that utilizes two individual-elements in series inside the fuse tube. One element, the spring actuated trigger assembly, operates on overloads up to 5 - 6 times the fuse current rating. The other element, the short-circuit section, operates on short-circuits up to its interrupting rating.
Electrical load — The part of the electrical system that actually uses the energy or does the work required.
Fast-acting fuse — A fuse that opens on overload and short- circuits very quickly. This type of fuse is not designed to withstand temporary overload currents associated with some electrical loads, when sized near the full load current of the circuit.
Fault current — Fault currents can be short-circuit currents, ground fault currents or arcing fault currents.
Fuse — An overcurrent protective device with a fusible link that operates and opens the circuit on an overcurrent condition.
High speed fuse — A fuse with no intentional time-delay in the overload range and designed to open as quickly as possible in the shortcircuit range. These fuses are often used to protect solid-state devices.
Inductive load — An electrical load which pulls a large amount of current – an inrush current – when first energized. After a few cycles or seconds, the current “settles down” to the full-load running current.
Interrupting rating — The rating which defines a fuse’s ability to safely interrupt and clear short-circuits. This rating is much greater than the amp rating of a fuse. The NEC defines interrupting rating as “The highest current at rated voltage that an overcurrent protective device is intended to interrupt under standard test conditions.”
Melting time — The amount of time required to melt the fuse link during a specified overcurrent. (See arcing time and clearing time.)
“NEC” Dimensions — These are dimensions once referenced in the NEC. They are common to Class H and K fuses and provide interchangeability between manufacturers for fuses and fusible equipment of given amp and voltage ratings.
Ohm — The unit of measure for electric resistance. An ohm is the amount of resistance that will allow one amp to flow under a pressure of one volt.
16-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse and fuse block cross reference, and index — 16**
Ohm’s Law — The relationship between voltage, current, and resistance, expressed by the equation E = IR, where E is the voltage in volts, I is the current in amps, and R is the resistance in ohms.
One time fuse — Generic term used to describe a Class H nonrenewable cartridge fuse, with a single-element.
Overcurrent — Any current in excess of the rated current of equipment or the ampacity of a conductor. It may result from overload, short-circuit or ground fault. (Ref. NEC Article 100.)
Overload — Operation of equipment in excess of normal, full load rating, or of a conductor in excess of rated ampacity that, when it persists for a sufficient length of time, would cause damage or dangerous overheating. A fault, such as a short-circuit or ground fault, is not an overload. (Ref. NEC Article 100.)
Peak let-through current, lp — The instantaneous value of peak current let-through by a current-limiting fuse, when it operates in its current-limiting range.
Renewable fuse (600 V and below) — A fuse in which the element, typically a zinc link, may be replaced after the fuse has opened, and then reused. Renewable fuses are made to Class H standards.
Resistive load — An electrical load which is characteristic of not having any significant inrush current. When a resistive load is energized, the current rises instantly to its steady-state value, without first rising to a higher value.
RMS current — The RMS (root-mean-square) value of any periodic current is equal to the value of the direct current which, flowing through a resistance, produces the same heating affect in the resistance as the periodic current does.
Short-circuit current rating (SCCR) — This term applies to components (single devices) and assemblies (equipment). For the component, it is the maximum fault current it can sustain without the occurrence of excessive damage. For equipment, it is the assembly’s rating, generally limited by the lowest component SCCR in the circuit as determined by an approved method such as UL 508A, Supplement SB.
Short-circuit withstand — The maximum current that an unprotected electrical component can sustain for a specified period of time without the occurrence of extensive damage. Typically applies to devices or components that do not have a marked short-circuit current rating, such as conductors, transfer switches or semiconductor devices.
Single-phasing — The condition that occurs when one phase of a three-phase system opens, either in a low voltage (secondary) or high voltage (primary) distribution system. Primary or secondary singlephasing can be caused by any number of events. This condition results in unbalanced currents in polyphase motors and unless protective measures are taken, may cause overheating and failure.
Threshold current — The symmetrical RMS (root mean square) available current at the threshold of the current-limiting range, where the fuse becomes current-limiting when tested to the industry standard. This value can be read off a peak let-through chart where the fuse curve intersects the A—B line. A threshold ratio is the relationship of the threshold current to the fuse’s continuous current rating.
Time-delay fuse — A fuse with a built-in delay that allows temporary and harmless inrush currents to pass without opening, but is so designed to open on sustained overloads and short-circuits.
Voltage rating — The maximum open circuit voltage in which a fuse can be used, yet safely interrupt an overcurrent. Exceeding the voltage rating of a fuse impairs its ability to clear an overload or short-circuit safely.
Semiconductor fuse — Fuses used to protect solid-state devices. See “high speed fuse.”
Short-circuit — Can be classified as an overcurrent which exceeds the normal full load current of a circuit by a factor many times (tens, hundreds or thousands greater). Also characteristic of this type of overcurrent is that it leaves the normal current carrying path of the circuit – it takes a “short cut” around the load and back to the source.
## Electrical formulas
**==> picture [536 x 213] intentionally omitted <==**
**----- Start of picture text -----**<br>
To find Single-phase Two-phase Three-phase Direct current<br>kVA x 1000 kVA x 1000 kVA x 1000<br>Amps when kVA is known Not applicable<br>E E x 2 E x 1.73<br>Hp x 746 Hp x 746 Hp x 746 Hp x 746<br>Amps when horsepower is known<br>E x % eff. x pf E x 2 x % eff. x pf E x 1.73 x % eff. x pf E x % eff.<br>kW x 1000 kW x 1000 kW x 1000 kW x 1000<br>Amps when kilowatts are known<br>E x pf E x 2 pf E x 1.73 x pf E<br>I x E x pf I x E x 2 x pf I x E x 1.73 x pf I x E<br>Kilowatts<br>1000 1000 1000 1000<br>I x E I x E x 2 I x E x 1.73<br>Kilovolt-amps Not applicable<br>1000 1000 1000<br>I x E % eff. x pf I x E x 2 x % eff. x pf I x E x 1.73 x % eff. x pf I x E x % eff.<br>Horsepower<br>746 746 746 746<br>Watts E x I x pf I x E x 2 x pf I x E x 1.73 x pf E x I<br>Load horsepower x 746<br>Energy efficiency<br>Load input kVA x 1000<br>Power consumed W kW<br>Power factor (pf) = or = cosØ<br>Apparent power VA kVA<br>**----- End of picture text -----**<br>
Where: I = Amps, E = Volts, Hp = Horsepower, kVA = Kilovolt-amps, kW = Kilowatts, pf = Power factor, % eff. = Percent efficiency
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
16-7
**16 — Fuse and fuse block cross reference, and index**
## FuseFinder fuse and fuse block cross reference
Eaton, the leader in circuit protection, power management and electrical safety offers an extensive selection of Bussmann series fuses and fuse blocks to meet your overcurrent protection needs.
If you cannot find a product cross, more extensive listings are available online at Eaton.com/bussmannseries/FuseFinder.
Or email our Application Engineers at FuseTech@Eaton.com.
If you need to find a replacement to another manufacturer's glass tube, low voltage branch and supplemental or high speed fuse, or fuse block or holder, use this quick cross reference FuseFinder to identify the Bussmann series replacement.
## Fuse cross reference
**==> picture [537 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Competitor Bussmann series Competitor Bussmann series Competitor Bussmann series<br>0481(amp) GMT-(amp)A 413(amp) MDM-(amp) ATMR(amp) KTK-R(amp)<br>**----- End of picture text -----**<br>
|Competitor<br>Bussmann series|Competitor<br>Bussmann series|Competitor<br>Bussmann series|
|---|---|---|
|0481(amp)<br>GMT-(amp)A|413(amp)<br>MDM-(amp)|ATMR(amp)<br>KTK-R(amp)|
|211(amp)<br>GDC-(amp)|414(amp)<br>ABS-(amp)|ATQ(amp)<br>FNQ-(amp)|
|212(amp)<br>GDB-(amp)|417(amp)<br>ABS-(amp)|ATQR(amp)<br>FNQ-R-(amp)|
|213(amp)<br>GDC-(amp)|418(amp)<br>TR/3216FF-(amp)|BBC(amp)<br>ABC-(amp)|
|215(amp)<br>S505-(amp)|429(amp)<br>3216FF(amp)|BDB(amp)<br>GDB-(amp)|
|216(amp)<br>GDA-(amp)|431(amp)<br>0603FA(amp)|BDC(amp)<br>GDC-(amp)|
|217(amp)<br>GDB-(amp)|5140(amp)<br>BAF-(amp)|BDL(amp)<br>MDL-(amp)|
|218(amp)<br>GDC-(amp)|5170(amp)<br>AGU-(amp)|BGC(amp)<br>AGC-(amp)|
|221(amp)<br>S505-V-(amp)|523(amp)<br>FNM-(amp)|BGX(amp)<br>AGX-(amp)|
|226(amp)<br>GDA-V-(amp)|5HF(amp)<br>GDA-(amp)|BLF(amp)<br>BAF-(amp)|
|227(amp)<br>GDB-V-(amp)|5HFP(amp)<br>GDA-V-(amp)|BLN(amp)<br>BAN-(amp)|
|228(amp)<br>GDC-V-(amp)|5HT(amp)<br>S505-(amp)A|BLS(amp)<br>BBS-(amp)|
|230(amp)<br>C515-(amp)|5MF(amp)<br>GMA-(amp)|BMA(amp)<br>GDA-(amp)|
|235(amp)<br>GMA-(amp)|5MFP(amp)<br>GMA-V-(amp)|CBO(amp) [4-160A]<br>HBO-(amp)|
|236(amp)<br>GMA-V-(amp)|5SF(amp)<br>GDB-(amp)|CCK(amp) [1-300A]<br>ACK-(amp)|
|238(amp)<br>GMD-V-(amp)|5ST(amp)<br>GDC-(amp)|CCL(amp) [30-100A]<br>ACL-(amp)|
|239(amp)<br>GMD-(amp)|6J(amp)X<br>KTK-(amp)|CCLB(amp) [20-250A]<br>KGJ-E-(amp)|
|257(amp)<br>ATC-(amp)|6R(amp)D<br>LPS-RK-(amp)SP|CCLW(amp) [1-300A]<br>KGJ-(amp)|
|297(amp) [auto fuse]<br>ATM-(amp)|702(amp)<br>HVJ-(amp)|CCMR[1-30A Only]<br>LP-CC(amp)|
|299(amp)<br>MAX-(amp)|703(amp)<br>HVL-(amp)|CDNC(amp)<br>CDN(amp)††|
|2AG220<br>C517-(amp)|81200(amp)ST<br>CBS-(amp)|CDSC(amp)<br>CDS(amp)†††|
|2AG230<br>C515-(amp)|A70P(amp)-1 or Type 1<br>FWP-(amp)A14F|CNL(amp)<br>ANL-(amp)|
|301(amp)<br>AGA-(amp)|A70P(amp)-4 or Type 4<br>FWP-(amp)A orB|CNN(amp)<br>ANN-(amp)|
|303(amp)<br>AGW-(amp)|A70Q(amp)-4 or Type 4<br>FWP-(amp)A or B|DCT[1-15A]<br>PV-(amp)A10F|
|307(amp)<br>SFE-(amp)|A70QS(amp)-14F<br>FWP-(amp)A14F|E(amp)FC<br>(amp)FC|
|311(amp)<br>AGC-(amp)|A70QS(amp)-22F<br>FWP-(amp)A22F|E(amp)FE<br>(amp)FE|
|312(amp)<br>AGC-(amp)|A70QS[35-200]-4<br>FWP-(amp)A or B|E(amp)FET<br>(amp)FET|
|313(amp)<br>MDL-(amp)|A70QS[225-400]-4 or 4K<br>FWP-(amp)A or B|E(amp)FM<br>(amp)FM|
|314(amp)<br>ABC-(amp)|A70QS[450-600]-4K<br>FWP-(amp)A or B|E(amp)FMM<br>(amp)FMM|
|315(amp)<br>MDL-V-(amp)|A70QS[700-800]-4<br>FWP-(amp)A or B|E(amp)LCT[6-20A]<br>(amp)LCT|
|318(amp)<br>AGC-V-(amp)|A50P(amp)-1<br>FWH-(amp)A14F|E(amp)LET[25-180A]<br>(amp)LET|
|322(amp)<br>GBB-(amp)|A50P(amp)-4<br>FWH-(amp)A or B|E(amp)LMMT[315-900A]<br>(amp)LMMT|
|323(amp)<br>MDA-(amp)|A50QS(amp)-4 or Type 4<br>FWH-(amp)A or B|E(amp)LMT[160-450A]<br>(amp)LMT|
|324(amp)<br>ABC-V-(amp)|A30QS(amp)-1 or Type 1<br>FWX-(amp)A14F|E100SF(amp) [20-30A]<br>FWJ-(amp)A14F|
|325(amp)<br>MDA-V-(amp)|A30QS[35-700]-4 or Type 4<br>FWX-(amp)A|E100S(amp) [40-2000A]<br>FWJ-(amp)|
|326(amp)<br>MDA-(amp)|A30QS[1000-1200]-128<br>FWX-(amp)AH|E15S(amp) [35-3000A]<br>FWA-(amp)A|
|334(amp)<br>GLD-(amp)|A15QS [1-30]-2<br>FWA-(amp)A10F|E15SF(amp) [5, 10, 15, 20,<br>25,30A]<br>FWA-(amp)A10F|
|336(amp)<br>GBA-(amp)|A15QS[35-60]-1<br>FWA-(amp)A21F|E25S(amp) [1000-2500A]<br>FWX-(amp)AH|
|361(amp)<br>AGX-(amp)|A15QS[70-400]-4<br>FWA-(amp)B|E25S(amp) [35-800A]<br>FWX-(amp)A|
|362(amp)<br>AGX-(amp)|A2D(amp)R<br>LPN-RK(amp)SP|E25SFX(amp) [5-30A]<br>FWX-(amp)14F|
|3770(amp)<br>SL-(amp)|A2K(amp)<br>KTN-R(amp)|E50S(amp)<br>FWH-(amp)|
|3780(amp)<br>S-(amp)|A3T(amp)<br>JJN(amp)|E50SF(amp) [5-30A]<br>FWH-(amp)14F|
|3785(amp)<br>T-(amp)|A4BQ[225-600]<br>KRP-CL-(amp)|E70S(amp)<br>FWP-(amp)|
|3AB(amp)<br>ABC-(amp)|A4BQ[601-6000]<br>KRP-C-(amp)SP|ECK(amp) [1-300A]<br>ACK-(amp)|
|3ABP(amp)<br>AGC-V-(amp)|A4BT[601-4000]<br>KLU[601-4000]|ECL(amp) [30-100A]<br>ACL-(amp)|
|3AG(amp)<br>AGC-(amp)|A4BY(amp)<br>KLU(amp)|ECN(amp)<br>FRN-R-(amp)|
|3AG311(amp)<br>AGC-(amp)|A4J(amp)<br>JKS(amp)|ECNR(amp)<br>FRN-R-(amp)|
|3AG312(amp)<br>AGC-(amp)|A6D(amp)R<br>LPS-RK(amp)SP|ECS(amp)<br>FRS-R-(amp)|
|3AG313(amp)<br>MDL-(amp)|A6K(amp)<br>KTS-R(amp)|ECSR(amp)<br>FRS-R-(amp)|
|3AG315(amp)<br>MDL-V-(amp)|A6T(amp)<br>JJS(amp)|ELR(amp)<br>GLR-(amp)|
|3AG318(amp)<br>AGC-V-(amp)|AG(amp)<br>SC(amp)|ENLE(amp)<br>ANL-(amp)|
|3SB(amp)<br>MDL-(amp)|AJT(amp)<br>LPJ(amp)SP|ENNE(amp)<br>ANN-(amp)|
|3SBP(amp)<br>MDL-V-(amp)|AM10/(amp)<br>LP-CC-(amp)|ERN(amp)<br>REN-(amp)*|
|401(amp)<br>GMT-(amp)A|AOK(amp)<br>ALS-(amp)|ERS(amp)<br>RES-(amp)**|
|411(amp)<br>ABS-(amp)|ATDR(amp)<br>LP-CC-(amp)|ESA(amp)<br>S-(amp)|
|412(amp)<br>ABS-(amp)|ATM(amp)<br>KLM(amp)|FA(amp)<br>SA(amp)|
* >60 A use FRN-R (250 V) ** >60 A use FRS-R (600 V) † >12 A use TL †† <10 A use FRN-R (600 V) ††† <10 A use FRS-R (600 V)
16-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse and fuse block cross reference, and index — 16**
## Fuse cross reference
**==> picture [537 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
Competitor fuse family Bussmann series Competitor fuse family Bussmann series Competitor fuse family Bussmann series<br>FII(amp) CGL-(amp) KLH(amp) [225-600A] FWH-(amp)A MEN(amp) FNM-(amp)<br>**----- End of picture text -----**<br>
|Competitor fuse family<br>Bussmann series|Competitor fuse family<br>Bussmann series|Competitor fuse family<br>Bussmann series|
|---|---|---|
|FII(amp)<br>CGL-(amp)|KLH(amp) [225-600A]<br>FWH-(amp)A|MEN(amp)<br>FNM-(amp)|
|FIIC(amp)<br>CGL-(amp)|KLH(amp) [35-200A]<br>FWH-(amp)B|MEQ(amp)<br>FNQ-(amp)|
|FIIM(amp) [125-200A]<br>(amp)M14CB|KLK(amp)<br>KTK-(amp)|MJS(amp)<br>C515-(amp)|
|FIIM(amp) [80-100A]<br>(amp)L09CB|KLKR(amp)<br>KTK-R-(amp)|MOL(amp)<br>BAF-(amp)|
|FLA(amp)<br>FNA-(amp)|KLLU(amp)<br>KLU-(amp)|NCL(amp)<br>KTN-R-(amp)|
|FLM(amp)<br>FNM-(amp)|KLMR(amp)<br>LP-CC-(amp)|NCLR(amp)<br>KTN-R-(amp)|
|FLN(amp)<br>FRN-R-(amp)|KLNR(amp)<br>KTN-R-(amp)|NLN(amp)<br>NON-(amp)|
|FLNR(amp)<br>FRN-R-(amp)|KLPC(amp)<br>KRP-C-(amp)SP|NLS(amp)<br>NOS-(amp)|
|FLQ(amp)<br>FNQ-(amp)|KLSR(amp)<br>KTS-R-(amp)|OT(amp)<br>NON(amp)|
|FLS(amp)<br>FRS-R-(amp)|KLW(amp)<br>FWA-(amp)10F|OTM(amp)<br>BAF-(amp)|
|FLSR(amp)<br>FRS-R-(amp)|KON(amp)<br>NON-(amp)|OTS(amp)<br>NOS(amp)|
|GFN(amp)<br>FNA-(amp)|KOS(amp)<br>NOS-(amp)|RF(amp)<br>REN(amp)*|
|GGU(amp)<br>AGU(amp)|L(amp)TD<br>KRP-C-(amp)SP|RFS(amp)<br>RES(amp)**|
|GL10/(amp)<br>KTK-(amp)|L15S(amp) [1-30A]<br>FWA-(amp)A10F|RLN(amp)<br>REN-(amp)*|
|HCLR(amp)<br>KTK-R-(amp)|L15S(amp) [35-60A]<br>FWA-(amp)A21F|RLS(amp)<br>RES(amp)**|
|HCTR(amp)<br>FNQ-R-(amp)|L15S(amp) [70-400A]<br>FWA-(amp)A|SAO(amp)<br>SA-(amp)|
|HSJ(amp)<br>DFJ(amp)|L25S(amp) [1-30A]<br>FWX-(amp)A14F|SBS(amp)<br>BBS-(amp)|
|IDSR[6-60A Only]<br>FRS-R-(amp)ID|L50S(amp) [1-30A]<br>FWH-(amp)A14F|SCL(amp)<br>KTS-R-(amp)|
|J(amp)<br>JKS-(amp)|L70S(amp) [1-30A]<br>FWP-(amp)A14F|SCLR(amp)<br>KTS-R-(amp)|
|JDL(amp)<br>LPJ-(amp)SP|LCU(amp)<br>KTU-(amp)|SEC(amp)<br>SC-(amp)|
|JFL(amp)<br>JKS-(amp)|LEN(amp)<br>FRN-R-(amp)|SLC(amp)<br>SC-(amp)|
|JLLN(amp)<br>JJN-(amp)|LENRK(amp)<br>LPN-RK-(amp)SP|SLO(amp)<br>SL-(amp)|
|JLLS(amp)<br>JJS-(amp)|LES(amp)<br>FRS-R-(amp)|SOO(amp)<br>S-(amp)|
|JLS(amp)<br>JKS-(amp)|LESR(amp)<br>FRS-R-(amp)|TLO(amp)<br>TL-(amp)|
|JTD(amp)<br>LPJ-(amp)SP|LESRK(amp)<br>LPS-RK-(amp)SP|TOO(amp)<br>T-(amp)|
|KLA(amp) [5, 10, 15, 20, 25,<br>30A]<br>FWA-(amp)A10F|LGR(amp)<br>GLR-(amp)|TR(amp)<br>FRN-R-(amp)|
|KLB(amp) [1-30A]<br>FWX-(amp)A14F|LHR(amp)<br>HLR(amp)|TRM(amp)<br>FNM-(amp)|
|KLC(amp)<br>KAC-(amp)|LKU(amp)<br>KLU-(amp)|TRS(amp)<br>FRS-R(amp)|
|KLDR(amp)<br>FNQ-R-(amp)|LLNRK(amp)<br>LPN-RK-(amp)SP|WOO(amp)<br>W-(amp)|
|KLH(amp) [1-30A]<br>FWH-(amp)A14F|LLSRK(amp)<br>LPS-RK-(amp)SP||
- >60 A use FRN-R (250 V) ** >60 A use FRS-R (600 V) † >12 A use TL. †† <10 A use FRN-R (600 V) ††† <10 A use FRS-R (600 V)
## Fuse block and holder cross reference
**==> picture [562 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
Competitor Bussmann series Competitor Bussmann series Competitor Bussmann series<br>LFJ60030(X)/(X)ID JM60030-(X)CR 6030(X)J JM60030-(X)CR (R)6J30A(X)S JM60030-(X)CR<br>**----- End of picture text -----**<br>
|Competitor<br>Bussmann series|Competitor<br>Bussmann series|Competitor<br>Bussmann series|Competitor<br>Bussmann series|
|---|---|---|---|
|LFJ60030(X)/(X)ID<br>JM60030-(X)CR|6030(X)J<br>JM60030-(X)CR|(R)6J30A(X)S<br>JM60030-(X)CR||
|LFJ60060(X)/(X)ID<br>JM60060-(X)CR|6060(X)J<br>JM60060-(X)CR|(R)6J60A(X)B<br>JM60060-(X)CR||
|LFJ60100(X)/(X)ID<br>JM60100-(X)CR***|610(XX)J<br>JM60100-(X)CR***|R6J100A(X)B<br>JM60100-(X)CR***||
|LFJ60200(X)/(X)ID<br>JM60200-(X)CR***|620(XX)J<br>JM60200-(X)CR***|6J200A(X)BFBD<br>JM60200-(X)CR***||
|LFJ60400(X)/(X)ID<br>JM60400-(X)CR***|640(XX)J<br>JM60400-(X)CR***|6J400A(X)BFBD<br>JM60400-(X)CR***||
|LFJ60600(X)/(X)ID<br>JM60600-(X)CR***|66(XX)J<br>JM60600-(X)CR***|6J600A(X)BFBD<br>JM60600-(X)CR***||
|LFR25030(X)/(X)ID<br>RM25030-(X)CR|203(XX)<br>HM25030-(X)CR|R30A(X)(XX)<br>RM25030-(X)CR||
|LFR25060(X)/(X)ID<br>RM25060-(X)CR|206(XX)<br>HM25060-(X)CR|R60A(X)(XX)<br>RM25060-(X)CR||
|LFR25100(X)/(X)ID<br>RM25100-(X)CR***|210(XX)<br>HM25100-(X)CR***|R100A(X)B<br>RM25100-(X)CR***||
|LFR25200(X)/(X)ID<br>RM25200-(X)CR***|220(XX)<br>HM25200-(X)CR***|R200A(X)BE<br>RM25200-(X)CR***||
|LFR25400(X)/(X)ID<br>RM25400-(X)CR***|240(XX)<br>HM25400-(X)CR***|R400A(X)B<br>RM25400-(X)CR***||
|LFR25600(X)/(X)ID<br>RM25600-(X)CR***|26(XX)<br>HM25600-(X)CR***|R600A(X)B<br>RM25600-(X)CR***||
|LFR60030(X)/(X)ID<br>RM60030-(X)CR|603(XX)<br>HM60030-(X)CR|6R30A(X)(XX)<br>RM60030-(X)CR||
|LFR60060(X)/(X)ID<br>RM60060-(X)CR|606(XX)<br>HM60060-(X)CR|6R60A(X)(XX)<br>RM60060-(X)CR|Cross reference<br>and index|
|LFR60100(X)/(X)ID<br>RM60100-(X)CR***|610(XX)<br>HM60100-(X)CR***|6R100A(X)B<br>RM60100-(X)CR***||
|LFR60200(X)/(X)ID<br>RM60200-(X)CR***|620(XX)<br>HM60200-(X)CR***|6R200A(X)BE<br>RM60200-(X)CR***||
|LFR60400(X)/(X)ID<br>RM60400-(X)CR***|640(XX)<br>HM60400-(X)CR***|6R400A(X)B<br>RM60400-(X)CR***||
|LFR60600(X)/(X)ID<br>RM60600-(X)CR***|66(XX)<br>HM60600-(X)CR***|6R600A(X)B<br>RM60600-(X)CR***||
|LFH25030(X)/(X)ID<br>HM25030-(X)CR|203(XX)R<br>RM25030-(X)CR|(R)F30A(X)(XX)<br>HM25030-(X)CR||
|LFH25060(X)/(X)ID<br>HM25060-(X)CR|206(XX)R<br>RM25060-(X)CR|(R)F60A(X)(XX)<br>HM25060-(X)CR||
|LFH25100(X)/(X)ID<br>HM25100-(X)CR***|210(XX)R<br>RM25100-(X)CR***|RF100A(X)B<br>HM25100-(X)CR***||
|LFH25200(X)/(X)ID<br>HM25200-(X)CR***|220(XX)R<br>RM25200-(X)CR***|F200A(X)BE<br>HM25200-(X)CR***||
|LFH25400(X)/(X)ID<br>HM25400-(X)CR***|240(XX)R<br>RM25400-(X)CR***|RF400A(X)B<br>HM25400-(X)CR***||
|LFH25600(X)/(X)ID<br>HM25600-(X)CR***|26(XX)R<br>RM25600-(X)CR***|F600A(X)B<br>HM25600-(X)CR***||
|LFH60030(X)/(X)ID<br>HM60030-(X)CR|603(XX)R<br>RM60030-(X)CR|(R)6F30A(X)(XX)<br>HM60030-(X)CR||
|LFH60060(X)/(X)ID<br>HM60060-(X)CR|606(XX)R<br>RM60060-(X)CR|(R)6F60A(X)(XX)<br>HM60060-(X)CR||
|LFH60100(X)/(X)ID<br>HM60100-(X)CR***|610(XX)R<br>RM60100-(X)CR***|R6F100A(X)B<br>HM60100-(X)CR***||
|LFH60200(X)/(X)ID<br>HM60200-(X)CR***|620(XX)R<br>RM60200-(X)CR***|6F200A(X)BE<br>HM60200-(X)CR***||
|LFH60400(X)/(X)ID<br>HM60400-(X)CR***|640(XX)R<br>RM60400-(X)CR***|R6F400A(X)B<br>HM60400-(X)CR***||
|LFH60600(X)/(X)ID<br>HM60600-(X)CR***|66(XX)R<br>RM60600-(X)CR***|6F600A(X)B<br>HM60600-(X)CR***||
|LFPSJ30(X)/(X)ID<br>CH30J(X)/(X)I|US3J(X)/(X)I<br>CH30J(X)/(X)I|6SJ30A(X)/(X)I<br>CH30J(X)/(X)I||
|LFPSJ60(X)/(X)ID<br>CH60J(X)/(X)I|US6J(X)/(X)I<br>CH60J(X)/(X)I|6SJ60A(X)/(X)I<br>CH60J(X)/(X)I||
|LPHV<br>CHPV|USPV<br>CHPV|6SC30A(X)-C/(X)I-C<br>CHCC(X)DU/(X)DIU||
|LPSC00(X)/(X)ID<br>CHCC(X)DU/(X)DIU|USCC(X)/(X)I<br>CHCC(X)DU/(X)DIU|6SM30A(X)-C/(X)I-C<br>CHM(X)DU/CHM(X)DIU||
|LPSM00(X)/(X)ID<br>CHM(X)DU/CHM(X)DIU|USM(X)/(X)I<br>CHM(X)DU/CHM(X)DIU|||
- *** Finger-safe covers are available for this block along with optional open fuse indication.
1. Some competitor blocks are adder blocks and/or have multiple terminal offerings for Cu/Al or Cu only conductors.
2. Wire ranges are not always the same. Please assure wire range is suitable for the application.
3. All blocks listed have a box lug for wire termination. Alternate connection types are available in the 30 and 60 amp range. If an alternate type is required, please see the appropriate Bussmann series product data sheet for catalog number and ordering information.
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
16-9
## **16 — Fuse and fuse block cross reference, and index**
## Catalog number index
For information on products not contained in this catalog, contact Customer Satisfaction, toll-free, at 855-287-7626 (855-BUSSMANN) between 7:00 a.m. — 6:00 p.m. Central time, M-F, or email BussCustSat@Eaton.com.
|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|
|---|---|---|---|---|
|_CIF06 . . . . . . . . . . . . . . . . . . . 5-4|12TDLEJ . . . . . . . . . . . . . . . . . 7-32|170H0238 . . . . . . . . . . . 4-78, 6-5, 11|2838. . . . . . . . . . . . . . . . . . . . . 2-2|46TB_ . . . . . . . . . . . . . . . . . . . 7-33|
|_CIF21 . . . . . . . . . . . . . . . . . . . 5-4|12THLEJ . . . . . . . . . . . . . . . . . 7-32|170H1007 . . . . . . . . . . . . . . . . 4-76|2A066_ . . . . . . . . . . . . . 8-49, 51, 53|46XAD_. . . . . . . . . . . . . . . . . . 7-33|
|_CIH07 . . . . . . . . . . . . . . . . . . . 5-5|12TKLEJ . . . . . . . . . . . . . . . . . 7-32|170H1013 . . . . . . . . . . . . . . . . 4-76|2A1910-_. . . . . . . . . . . . . . . . . 15-4|5.5ABWNA_E . . . . . . . . . . . . . . 7-26|
|_CIK07 . . . . . . . . . . . . . . . . . . . 5-5|12TXLEJ . . . . . . . . . . . . . . . . . 7-32|170H3003 . . . . . . . . . . . . . . . . 4-77|2ACLS-_R. . . . . . . . . . . . . . . . . 7-22|5.5AMWNA_E. . . . . . . . . . . . . . 7-26|
|_CIL14 . . . . . . . . . . . . . . . . . . . 5-5|14002-_. . . . . . . . . . . . . . . . . . 9-17|170H3004 . . . . . . . . . . . . . . . . 4-77|2BCLS-_R. . . . . . . . . . . . . . . . . 7-22|5.5CAV_E. . . . . . . . . . . . . . . . . 7-26|
|_CT . . . . . . . . . . . . . . . . . . . . 4-17|14004-_. . . . . . . . . . . . . . . . . . 9-17|170H3005 . . . . . . . . . . . . . . . . 4-77|2CLE-_E. . . . . . . . . . . . . . . . . . . 7-3|5.5CAVH_E. . . . . . . . . . . . . . . . 7-26|
|_D125. . . . . . . . . . . . . . . . . . . . 5-9|15.5CAV_E . . . . . . . . . . . . . . . . 7-26|170H3006 . . . . . . . . . . . . . . . . 4-77|2CLE-_M-C. . . . . . . . . . . . . . . . . 7-3|5.5VFNHA . . . . . . . . . . . . . . . . 7-31|
|_D16 . . . . . . . . . . . . . . . . . . . . 5-9|15.5CAVH_E . . . . . . . . . . . . . . . 7-26|170M_ . . . . . . . . . . . . . . . . . . . . †|2CLE-_M-D . . . . . . . . . . . . . .7-3, 22|5.5VKNHA . . . . . . . . . . . . . . . . 7-31|
|_D27 . . . . . . . . . . . . . . . . . . . . 5-9|15087 . . . . . . . . . . . . . . . . . . 14-10|175GDMSJ_E . . . . . . . . . . . . . . 7-21|2CLE-_M-E . . . . . . . . . . . . . . .7-3, 22|5592-01 . . . . . . . . . . . . . . . . . 3-16|
|_D33 . . . . . . . . . . . . . . . . . . . . 5-9|15100-_. . . . . . . . . . . . . . . . . . 14-7|175GFMSJ_E . . . . . . . . . . . . . . 7-21|2CLS-_R . . . . . . . . . . . . . . . . . 7-22|55GDMSJ_E . . . . . . . . . . . . . . . 7-21|
|_EET. . . . . . . . . . . . . . . . . . . . 4-17|15188 . . . . . . . . . . . . . . . . . . . 10-6|175GXMSJ_E . . . . . . . . . . . . . . 7-21|2HCLS-_R . . . . . . . . . . . . . . . . 7-22|55GFMSJ_E . . . . . . . . . . . . . . . 7-21|
|_ET . . . . . . . . . . . . . . . . . . . . 4-17|15188J-2-J . . . . . . . . . . . . . . . . 10-6|175GXQSJ_E. . . . . . . . . . . . . . . 7-21|2NCLPT-_. . . . . . . . . . . . . . . . . 7-26|5674-_ . . . . . . . . . . . . . . . . . . 3-16|
|_FE. . . . . . . . . . . . . . . . . . . . . 4-17|155GXQSJ_E. . . . . . . . . . . . . . . 7-21|1A0065 . . . . . . 7-3, 7, 11, 22, 23, 25, 36|3.6ABCNA_ . . . . . . . . . . . . . . . 7-26|5681-01 . . . . . . . . . . . . . . . . . 3-16|
|_FEE. . . . . . . . . . . . . . . . . . . . 4-17|15800-_. . . . . . . . . . . . . . . . . . 14-5|1A1119-_. . . . . . . . . . . . . . . . . 3-15|3.6ABWNA_ . . . . . . . . . . . . . . . 7-26|5682-_ . . . . . . . . . . . . . . . . . . 3-16|
|_FM . . . . . . . . . . . . . . . . . . . . 4-19|15BHLE-_E. . . . . . . . . . . . . . . . 7-18|1A1120-_. . . . . . . . . . . . . . . . . 3-15|3.6ADLSJ . . . . . . . . . . . . . . . . . 7-32|5960-_ . . . . . . . . . . . . . . . . . . 3-16|
|_FMM . . . . . . . . . . . . . . . . . . . 4-19|15CLE-_E. . . . . . . . . . . . . . . . . 7-15|1A1706-_. . . . . . . . . . . . . . . . 14-10|3.6ADOSJ . . . . . . . . . . . . . . . . 7-32|5ACLS-_R. . . . . . . . . . . . . . . . . 7-23|
|_H07C . . . . . . . . . . . . . . . . . . . 5-6|15CLE-_E-D . . . . . . . . . . . . . . . 7-15|1A1837 . . . . . . . . . . . . . . . . . . 7-26|3.6CAV_ . . . . . . . . . . . . . . . . . 7-26|5ACLS-30. . . . . . . . . . . . . . . . . 7-23|
|_K07CR . . . . . . . . . . . . . . . . . . . 5-6|15CLE-_M-C . . . . . . . . . . . . . . . 7-15|1A1907-_. . . . . . . . . . . . . . . . . 3-15|3.6WDFHO. . . . . . . . . . . . . . . . 7-31|5AHLE-_E . . . . . . . . . . . . . . . . . 7-8|
|_L09C . . . . . . . . . . . . . . . . . . . . 5-6|15CLE-_M-D. . . . . . . . . . . . . . . 7-15|1A2294 . . . . . . . . . . . . . . . . . . 8-47|3.6WDLSJ . . . . . . . . . . . . . . . . 7-31|5BCLS-_R. . . . . . . . . . . . . . . . . 7-23|
|_L14C . . . . . . . . . . . . . . . . . . . . 5-6|15CLE-_M-E . . . . . . . . . . . . . . . 7-15|1A3398-07-R . . . . . . . . . . . . . . 3-15|3.6WDOH6. . . . . . . . . . . . . . . . 7-31|5BCLS-30. . . . . . . . . . . . . . . . . 7-23|
|_LCT. . . . . . . . . . . . . . . . . . . . 4-15|15CLPT-_E . . . . . . . . . . . . . . . . 7-26|1A3399-_. . . . . . . . . . . . . . . . . 3-14|3.6WDOSJ . . . . . . . . . . . . . . . . 7-32|5BHCL-_E . . . . . . . . . . . . . . . . . 7-8|
|_LET. . . . . . . . . . . . . . . . . . . . 4-15|15CLPT-_M-A . . . . . . . . . . . . . . 7-29|1A3400-_. . . . . . . . . . . . . . . . . 3-16|3.6WFFHO . . . . . . . . . . . . . . . . 7-31|5BHLE-_E. . . . . . . . . . . . . . . . . . 7-8|
|_LMMT . . . . . . . . . . . . . . . . . . 4-16|15CLPT-_M-B . . . . . . . . . . . . . . 7-29|1A4533-_. . . . . . . . . . . . . . . . . 3-15|3.6WFLSJ. . . . . . . . . . . . . . . . . 7-31|5CLE-_E. . . . . . . . . . . . . . . . . 7-5, 8|
|_LMT . . . . . . . . . . . . . . . . . . . 4-16|15HCL-_E. . . . . . . . . . . . . . . . . 7-18|1A4534-_. . . . . . . . . . . . . . . . . 3-15|3.6WFOH6 . . . . . . . . . . . . . . . . 7-31|5CLE-_E-D . . . . . . . . . . . . . . . . . 7-5|
|_M09C . . . . . . . . . . . . . . . . . . . 5-6|15HLE-_E. . . . . . . . . . . . . . . . . 7-15|1A5018-_. . . . . . . . . . . . . . . . . 3-14|3.6WFOSJ . . . . . . . . . . . . . . . . 7-32|5CLE-_M-C. . . . . . . . . . . . . . . . . 7-5|
|_M14C . . . . . . . . . . . . . . . . . . . 5-6|15HLE-_M-C. . . . . . . . . . . . . . . 7-15|1A5600 . . . . . . . . . . . . . . . . . . 2-14|3.6WJON6 . . . . . . . . . . . . . . . . 7-31|5CLE-_M-D . . . . . . . . . . . . . .7-5, 23|
|_MMT. . . . . . . . . . . . . . . . . . . 4-19|15HLE-_M-D. . . . . . . . . . . . . . . 7-15|1A5601 . . . . . . . . . . . . . . . . . . 3-14|3.6WKFHO . . . . . . . . . . . . . . . . 7-31|5CLE-_M-E . . . . . . . . . . . . . . .7-5, 23|
|_MT . . . . . . . . . . . . . . . . . . . . 4-19|15HLE-_M-E . . . . . . . . . . . . . . . 7-15|1A5602 . . . . . . . . . . . . . . . . . . 3-14|3.6WKLSJ. . . . . . . . . . . . . . . . . 7-32|5CLPT-_E . . . . . . . . . . . . . . . . . 7-26|
|_NHG000B. . . . . . . . . . . . . . . . 5-10|15KU_. . . . . . . . . . . . . . . . . . . 7-33|1A5778 . . . . . . . . . . . . . . . . . . 2-14|32BS. . . . . . . . . . . . . . . . . . . . 5-15|5CLPT-_M-A . . . . . . . . . . . . . . . 7-29|
|_NHG000B-690. . . . . . . . . . . . . 5-11|15LHLE-_E . . . . . . . . . . . . . . . . 7-15|1A5779 . . . . . . . . . . . . . . . . . . 2-14|32LSCC . . . . . . . . . . . . . . . . . . 5-15|5CLS-_R . . . . . . . . . . . . . . . . . 7-23|
|_NHG00B . . . . . . . . . . . . . . . . 5-10|15NCLPT-_E-A . . . . . . . . . . . . . 7-26|1A5780 . . . . . . . . . . . . . . . . . . 2-14|36ABGNA_. . . . . . . . . . . . . . . . 7-26|5CLS-30 . . . . . . . . . . . . . . . . . 7-23|
|_NHG00B-690. . . . . . . . . . . . . . 5-11|15NCLPT-_E-B. . . . . . . . . . . . . . 7-26|1BS10_ . . . . . . . . . . . . . . 4-14, 8-39|36CAV_. . . . . . . . . . . . . . . . . . 7-26|5HCL-_E . . . . . . . . . . . . . . . . . . 7-8|
|_NHG01B . . . . . . . . . . . . . . . . 5-10|15SBR_ . . . . . . . . . . . . . . . . . . 7-33|20BS. . . . . . . . . . . . . . . . . . . . 5-15|36TDQSJ . . . . . . . . . . . . . . . . . 7-32|5HCLS-_R . . . . . . . . . . . . . . . . 7-23|
|_NHG02B . . . . . . . . . . . . . . . . 5-10|15TB_ . . . . . . . . . . . . . . . . . . . 7-33|20LSC . . . . . . . . . . . . . . . . . . . 5-15|36TFQSJ . . . . . . . . . . . . . . . . . 7-32|5HCLS-30 . . . . . . . . . . . . . . . . 7-23|
|_NHG03B . . . . . . . . . . . . . . . . 5-10|15XAD_. . . . . . . . . . . . . . . . . . 7-33|24ABGNA_. . . . . . . . . . . . . . . . 7-26|36TXQEJ . . . . . . . . . . . . . . . . . 7-32|5HLE-_E . . . . . . . . . . . . . . . . . . 7-5|
|_NHG0B . . . . . . . . . . . . . . . . . 5-10|160_. . . . . . . . . . . . . . . . . . .9-9, 15|24CAV_. . . . . . . . . . . . . . . . . . 7-26|3723. . . . . . . . . . . . . . . . . . . . 8-14|5HLE-_M-C . . . . . . . . . . . . . . . . 7-5|
|_NHG1B . . . . . . . . . . . . . . . . . 5-10|162_. . . . . . . . . . . . . . . . 9-9, 13, 15|24TDMEJ. . . . . . . . . . . . . . . . . 7-32|3742. . . . . . . . . . . . . . . . . . . . 8-14|5HLE-_M-D . . . . . . . . . . . . . .7-5, 23|
|_NHG1B-690 . . . . . . . . . . . . . . 5-11|163_. . . . . . . . . . . . . . . . 9-9, 13, 15|24TFMEJ . . . . . . . . . . . . . . . . . 7-32|3743. . . . . . . . . . . . . . . . . . . . 8-14|5HLE-_M-E. . . . . . . . . . . . . . .7-5, 23|
|_NHG2B . . . . . . . . . . . . . . . . . 5-10|164_. . . . . . . . . . . . . . . . . . . . . 9-9|24THMEJ. . . . . . . . . . . . . . . . . 7-32|3828-_ . . . . . . . . . . . . . . . . . . . 8-5|5LCLS-_R . . . . . . . . . . . . . . . . . 7-23|
|_NHG2B-690 . . . . . . . . . . . . . . 5-11|165_. . . . . . . . . . . . . . . . 9-9, 13, 15|24TXMEJ . . . . . . . . . . . . . . . . . 7-32|38CAV_E . . . . . . . . . . . . . . . . . 7-26|5MCLS-_R-_A . . . . . . . . . . . . . . 7-23|
|_NHG3B . . . . . . . . . . . . . . . . . 5-10|17.5ABGNA_ . . . . . . . . . . . . . . 7-26|258GDQSJ_E . . . . . . . . . . . . . . 7-21|38CAVH_E . . . . . . . . . . . . . . . . 7-26|5MCLS-_R-_B . . . . . . . . . . . . . . 7-23|
|_NHG3B-690 . . . . . . . . . . . . . . 5-11|17.5CAV_. . . . . . . . . . . . . . . . . 7-26|258GXQSJ_E. . . . . . . . . . . . . . . 7-21|38CLPT-_E . . . . . . . . . . . . . . . . 7-26|5NCLPT-_E. . . . . . . . . . . . . . . . 7-26|
|_NHG4B . . . . . . . . . . . . . . . . . 5-10|17.5TDLSJ . . . . . . . . . . . . . . . . 7-32|258GXZSJ_E. . . . . . . . . . . . . . . 7-21|38CLPT-_M-A . . . . . . . . . . . . . . 7-29|5NCLPT-_E-A . . . . . . . . . . . . . . 7-26|
|_NHG4B-690 . . . . . . . . . . . . . . 5-11|17.5TDMEJ. . . . . . . . . . . . . . . . 7-32|25CLPT-_E . . . . . . . . . . . . . . . . 7-26|38GFZSJ_E. . . . . . . . . . . . . . . . 7-21|5TPH . . . . . . . . . . . . . . . . . . . 15-4|
|_NZ01. . . . . . . . . . . . . . . . . . . . 5-9|17.5TFLSJ . . . . . . . . . . . . . . . . 7-32|25CLPT-_M-A . . . . . . . . . . . . . . 7-29|4164. . . . . . . . . . . . . . . . . . . . . 2-4|60/100BS. . . . . . . . . . . . . . . . . 5-15|
|_NZ02. . . . . . . . . . . . . . . . . . . . 5-9|17.5THMEJ. . . . . . . . . . . . . . . . 7-32|25KU_. . . . . . . . . . . . . . . . . . . 7-33|4164-FR . . . . . . . . . . . . . . . . . . 2-4|63/100LSC . . . . . . . . . . . . . . . . 5-15|
|_P11C. . . . . . . . . . . . . . . . . . . . 5-6|17.5TKMEJ . . . . . . . . . . . . . . . . 7-32|25SBR_ . . . . . . . . . . . . . . . . . . 7-33|4393-_ . . . . . . . . . . . . . . . . . . . 8-5|64200 . . . . . . . . . . . . . . . . . . . . 2-3|
|_R11C. . . . . . . . . . . . . . . . . . . . 5-6|170H0069 . . . . . . . . . . . . . . . . 4-78|25TB_ . . . . . . . . . . . . . . . . . . . 7-33|4421. . . . . . . . . . . . . . . . . . . . 8-14|64300 . . . . . . . . . . . . . . . . . . . . 2-3|
|11675-_. . . . . . . . . . . . . . . . . . 9-17|170H023_ . . . . . . . . . . . . . . . . 8-40|25XAD_. . . . . . . . . . . . . . . . . . 7-33|4515. . . . . . . . . . . . . . . . . . . . 8-14|68300 . . . . . . . . . . . . . . . . . . . . 2-3|
|11725-_. . . . . . . . . . . . . . . . . . 9-17|170H0235 . . . . . . . . . . . . . . . . 4-78|270303 . . . . . . . . . . . . . . . .7-20, 36|4520-_ . . . . . . . . . . . . . . . . . . . 8-5|68600 . . . . . . . . . . . . . . . . . . . . 2-3|
|12ABCNA_. . . . . . . . . . . . . . . . 7-26|170H0236 . . . . . . . . . . . 4-78, 6-5, 11|2778. . . . . . . . . . . . . . . . . . . . . 2-2|46KU_. . . . . . . . . . . . . . . . . . . 7-33|7.2ABCNA_ . . . . . . . . . . . . . . . 7-26|
|12CAV_. . . . . . . . . . . . . . . . . . 7-26|170H0237 . . . . . . . . . . . . . . . . 4-78|2837. . . . . . . . . . . . . . . . . . . . . 2-2|46SBR_ . . . . . . . . . . . . . . . . . . 7-33|7.2ABWNA_ . . . . . . . . . . . . . . . 7-26|
- Due to the many sizes, AC and DC voltage ratings, amp ratings and standards associated with the 170M high speed fuse catalog number prefix, please see the high speed fuse section table of contents to locate your specific fuse.
16-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse and fuse block cross reference, and index — 16**
## Catalog number index
For information on products not contained in this catalog, contact Customer Satisfaction, toll-free, at 855-287-7626 (855-BUSSMANN) between 7:00 a.m. — 6:00 p.m. Central time, M-F, or email BussCustSat@Eaton.com.
|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|||
|---|---|---|---|---|---|---|
|7.2AMWNA_E. . . . . . . . . . . . . . 7-26|AGX-_. . . . . . . . . . . . . . . . . . . . 3-8|BSPD_. . . . . . . . . . . . . . . . . . 13-10|CCP2-MW1-6 . . . . . . . . . . . . . 11-13|CH14-L . . . . . . . . . . . . . . . . . . 4-37|||
|7.2CAV_ . . . . . . . . . . . . . . . . . 7-26|AL-D. . . . . . . . . . . . . . . . . . . . 4-37|BSPD_DING_ . . . . . . . . . . . . . 13-28|CCP2-MW2-3 . . . . . . . . . .1-14, 11-10|CH14-MS1 . . . . . . . . . . . . . . . . 4-37|||
|7.2TDLSJ . . . . . . . . . . . . . . . . . 7-32|ANL-_ . . . . . . . . . . . . . . . . . . . . 2-4|BSPD48RJ45. . . . . . . . . . . . . . 13-27|CCP2-MW2-3 . . . . . . . . . .1-14, 11-10|CH14-MS3 . . . . . . . . . . . . . . . . 4-37|||
|7.2TFLSJ . . . . . . . . . . . . . . . . . 7-32|ANN-_. . . . . . . . . . . . . . . . . . . . 2-4|BSPH2A_ _ _ _LVR . . . . . . . . . . 13-25|CCP2-MW2-3 . . . . . . . . . . . . . 11-14|CH14-P . . . . . . . . . . . . . . . . . . 4-37|||
|7.2WFMSJ . . . . . . . . . . . . . . . . 7-31|AT512 . . . . . . . . . . . . . . . . . . . 10-4|BSPM1A_ _ _ _LV(R) . . . . . . . . . 13-23|CCP2-MW2-6 . . . . . . . . . .1-14, 11-10|CH22_ . . . . . . . . . . . . . . . . . . 8-17|||
|7.2WFNHO. . . . . . . . . . . . . . . . 7-31|ATC-_ . . . . . . . . . . . . . . . . . . . 2-13|BSPMA1_S2GR . . . . . . . . . . . . 13-15|CCP2-MW2-6 . . . . . . . . . .1-14, 11-10|CH22_DIU . . . . . . . . . . . . . . . . 4-37|||
|7.2WKMSJ . . . . . . . . . . . . . . . . 7-31|ATC-FHID. . . . . . . . . . . . . . . . . 2-14|BSPMA2_S3GR . . . . . . . . . . . . 13-17|CCP2-MW2-6 . . . . . . . . . . . . . 11-14|CH22_DMSU-F . . . . . . . . . . . . . 4-37|||
|7.2WKNHO. . . . . . . . . . . . . . . . 7-31|ATM-_. . . . . . . . . . . . . . . . . . . 2-12|BSPMA3_DLGR . . . . . . . . . . . . 13-19|CCP2-MW6-6 . . . . . . . . . . . . . 11-14|CH22_DNIU . . . . . . . . . . . . . . . 4-37|||
|70_-_A . . . . . . . . . . . . . . . . . 14-10|ATM-_LP . . . . . . . . . . . . . . . . . 2-12|BSPMA3_WYGR. . . . . . . . . . . . 13-19|CCP2-NFPA-_ . . . . . . . . . . . 11-16, 44|CH22_DNU . . . . . . . . . . . . . . . 4-37|||
|72_ . . . . . . . . . . . . . . . . . . . 14-10|ATM-FHID . . . . . . . . . . . . . . . . 2-14|BSPMA4_WYNGR . . . . . . . . . . 13-21|CCP2-PB_ . . . . . . . . . . . . . . . 11-18|CH22_DU . . . . . . . . . . . . . . . . 4-37|||
|72KU_. . . . . . . . . . . . . . . . . . . 7-33|ATR-_ . . . . . . . . . . . . . . . . . . . 2-12|BVL50. . . . . . . . . . . . . . 6-5, 11, 8-40|CCP2-PB2 . . . . . . . . . . . .1-14, 11-10|CH22-_PS . . . . . . . . . . . . . . . . 8-17|||
|72SBR_ . . . . . . . . . . . . . . . . . . 7-33|B . . . . . . . . . . . . . . . . .10-11, 13, 15|C10G_. . . . . . . . . . . . . . . . . . . 5-13|CCP2-PB6 . . . . . . . . . . . .1-14, 11-10|CH221DNXU . . . . . . . . . . . . . . 4-37|||
|72TB_ . . . . . . . . . . . . . . . . . . . 7-33|B221-_ . . . . . . . . . . . . . . . . . . 12-6|C10M_ . . . . . . . . . . . . . . . . . . 5-14|CCP2-PLC-100. . . . . . . . . . . . . 11-21|CH223DNMSU-F . . . . . . . . . . . . 4-37|||
|72XAD_. . . . . . . . . . . . . . . . . . 7-33|B222-_ . . . . . . . . . . . . . . . . . . 12-6|C14G_. . . . . . . . . . . . . . . . . . . 5-13|CCP2-PLC-IND. . . . . . . . . . . 11-21, 46|CH22-CTP . . . . . . . . . . . . . . . . 8-17|||
|7BCLS-_R. . . . . . . . . . . . . . . . . 7-25|BAC0_. . . . . . 11-56, 58, 60, 62, 64, 67,|C14M_ . . . . . . . . . . . . . . . . . . 5-14|CCP2R-_-_CF . . . . . . . . . . . . . . 11-5|CH22-IP20 . . . . . . . . . . . . . . . . 4-37|||
|8ACLS-_R. . . . . . . . . . . . . . . . . 7-25|. . . . . . . . . . 73, 75, 77, 82, 86, 88, 90|C22G_. . . . . . . . . . . . . . . . . . . 5-13|CCP2R-_-30CC . . . . . . . . . . . . 11-39|CH22-L . . . . . . . . . . . . . . . . . . 4-37|||
|8AHLE-_E . . . . . . . . . . . . . . . . 7-13<br>8BHLE-_E. . . . . . . . . . . . . . . . . 7-13<br>8CLE-_E. . . . . . . . . . . . . . . . . . 7-11|BAC1_. . . . . . . . . . . . . .11-75, 77, 88<br>BAC-HOLDER2 . . . . . . . . . . . . 11-56<br>BAF-_ . . . . . . . . . . . . . . . . . . . . 2-5|C22M_ . . . . . . . . . . . . . . . . . . 5-14<br>C30BS. . . . . . . . . . . . . . . . . . . 5-15<br>C30F. . . . . . . . . . . . . . . . . . . . 5-15|CCP2R-_-30M . . . . . . . . . . . . . 11-39<br>CCP2RL-_-_CF. . . . . . . . . . . . . . 11-5<br>CCP2RL-_-30CC. . . . . . . . . . . . 11-39|CH22-MS1 . . . . . . . . . . . . . . . . 4-37<br>CH22-MS3 . . . . . . . . . . . . . . . . 4-37<br>CHCC_D_U . . . . . . . . . . . . . . . . 8-8|||
|8CLE-_M-C. . . . . . . . . . . . . . . . 7-11<br>8CLE-_M-D . . . . . . . . . . . . . .7-5, 23<br>8CLE-_M-E . . . . . . . . . . . . . . . . 7-11<br>8CLPT-_E-A . . . . . . . . . . . . . . . 7-26|BAO-_. . . . . . . . . . . . . . . . . . . . 5-7<br>BB1P100M_ . . . . . . . . . . . . . . . 8-10<br>BB3P100M_ . . . . . . . . . . . . . . . 8-10<br>BBS-_ . . . . . . . . . . . . . . . . . . . . 2-7|C30FBS . . . . . . . . . . . . . . . . . . 5-15<br>C515-_-R . . . . . . . . . . . . . . . . . . 3-2<br>C517-3-R . . . . . . . . . . . . . . . . . . 3-3<br>C518-_-R . . . . . . . . . . . . . . . . . . 3-2|CCP2RL-_-30M . . . . . . . . . . . . 11-39<br>CCP2-RM_ . . . . . . . . . . . . . . . 11-18<br>CCP2S-_-_CF . . . . . . . . . . . . . . 11-5<br>CCP2S-_-30CC . . . . . . . . . . . . 11-39|CHCC1DI-48U. . . . . . . . . . . . . . . 8-8<br>CHM_D_U . . . . . . . . . . . . . . . . . 8-8<br>CHM_DIU . . . . . . . . . . . . . . . . 4-36<br>CHM_DN_U . . . . . . . . . . . . . . . . 8-8|||
|8CLPT-_M-A . . . . . . . . . . . . . . . 7-29<br>8CLPT-_M-B . . . . . . . . . . . . . . . 7-29<br>8CLS-_R . . . . . . . . . . . . . . . . . 7-25|BC-_ . . . . . . . . . . . . . . . . . . . . . 5-8<br>BCCMM603-3_ . . . . . . . . . . . . . . 8-6<br>BCM603-_ . . . . . . . . . . . . . . . . . 8-6|C519-_-R . . . . . . . . . . . . . . . . . . 3-2<br>C520-_-R . . . . . . . . . . . . . . . . . . 3-2<br>C5268-_ . . . . . . . . . . . . . 4-14, 8-39|CCP2S-_-30M . . . . . . . . . . . . . 11-39<br>CCP2-SH_-_ . . . . . . . . . . . . 11-16, 44<br>CCP2SL-_-_CF. . . . . . . . . . . . . . 11-5|CHM_DNU. . . . . . . . . . . . . . . . 4-36<br>CHM_DU. . . . . . . . . . . . . . . . . 4-36<br>CHM1DNXU . . . . . . . . . . . . . . . 4-36|||
|8HCL-_E . . . . . . . . . . . . . . . . . 7-13|BD-_. . . . . . . . . . . . . . . . . . . . . 5-8|C60BS. . . . . . . . . . . . . . . . . . . 5-15|CCP2SL-_-30CC. . . . . . . . . . . . 11-39|CH-PLC2 . . . . . . . . . . . . . . . . . 8-11|||
|8HLE-_E . . . . . . . . . . . . . . . . . 7-11|BG301_. . . . . . . . . . . . . . . . . . 8-15|C60F. . . . . . . . . . . . . . . . . . . . 5-15|CCP2SL-_-30M . . . . . . . . . . . . 11-39|CHPV_U . . . . . . . . . . . . . . . 6-8, 8-8|||
|8HLE-_M-C . . . . . . . . . . . . . . . 7-11|BG302_. . . . . . . . . . . . . . . . . . 8-15|C60FBS . . . . . . . . . . . . . . . . . . 5-15|CCP2-SM . . . . . . . . . . . . . . . . 11-18|CHPV14_. . . . . . . . . . . . . . . . . 8-16|||
|8HLE-_M-D . . . . . . . . . . . . . .7-5, 25<br>8HLE-_M-E. . . . . . . . . . . . . . . . 7-11<br>8NCLPT-_E. . . . . . . . . . . . . . . . 7-26<br>8NCLPT-_E-A . . . . . . . . . . . . . . 7-26<br>8NCLPT-_E-B . . . . . . . . . . . . . . 7-26<br>9078A67G04 . . . . . . . . "7-3, 7, 11, 22,<br>. . . . . . . . . . . . . . . . . . . 23, 25, 36<br>9435-1/2 . . . . . . . . . . . . . . . . . 8-42<br>9732. . . . . . . . . . . . . . . . . . . . 8-42|BG303_. . . . . . . . . . . . . . . . . . 8-15<br>BH-0_ . . . . . . . . . . . . . . . 4-14, 8-39<br>BH-1_ . . . . . . . . . . . . . . . 4-14, 8-39<br>BH-2_ . . . . . . . . . . . . . . . 4-14, 8-39<br>BH-3-_ . . . . . . . . . . . . . . 4-14, 8-39<br>BK . . . . . . . . . . . . . . . . . . . . . 8-42<br>BK . . . . . . . . . . . . . . . . . . . . . 8-42<br>BK . . . . . . . . . . . . . . . . . . . . . 8-43<br>BK . . . . . . . . . . . . . . . . . . . . . 8-44|C7021-_ . . . . . . . . . . . . . . . . . 10-9<br>CCP2-_-30CC . . . . . . . . . . . . . 11-39<br>CCP2-_-30M. . . . . . . . . . . . . . 11-39<br>CCP2-_-CF . . . . . . . . . . . . . 11-2, 5, 9<br>CCP2-1-DCC. . . . . . . . . . . . . . 11-39<br>CCP2-1-DCM . . . . . . . . . . . . . 11-39<br>CCP2-AUX . . . . . . . . . . . . . 11-19, 45<br>CCP2-AUX-100 . . . . . . . . . . . . 11-19<br>CCP2-AUX-S . . . . . . . . . . . . . . 11-20|CCP2-TS_-3 . . . . . . . . . . . . . . 11-18<br>CCP2-TS2-3 . . . . . . . . . . .1-14, 11-10<br>CCP2-TS6-3 . . . . . . . . . . .1-14, 11-10<br>CCPLP-_-20G-S . . . . . . . . . . . . 11-53<br>CCPLP-_-30CC-S . . . . . . . . . . . 11-53<br>CCPLP-_-30M-S. . . . . . . . . . . . 11-53<br>CD-_. . . . . . . . . . . . . . . . . . . . . 5-8<br>CDN-_. . . . . . . . . . . . . . . . . . . . 5-2<br>CDS-_ . . . . . . . . . . . . . . . . . . . . 5-2|CHPV15L85 . . . . . . . . . . . . . . . 6-10<br>CHSF-_ . . . . . . . . . . . . . . . . . . . 4-3<br>CL1 . . . . . . . . . . . . . . . . . . . . 4-21<br>CLE-_-C. . . . . . . . . . . . .7-3, 5, 11, 15<br>CLE-_-D. . . . . . . . . . . . .7-3, 5, 11, 15<br>CLE-_-E . . . . . . . . . . . . .7-3, 5, 11, 15<br>CLPT-_E-B . . . . . . . . . . . . . . . . 7-26<br>CLPT-_L. . . . . . . . . . . . . . . . . . 7-29<br>CM_CF . . . . . . . . . . . . . . . . . . 5-15|Cross reference|and index|
|9838. . . . . . . . . . . . . . . . . . . . 8-48<br>9841. . . . . . . . . . . . . . . . . . . . 8-48<br>A . . . . . . . . . . . . . . . . . . . . . . 2-11<br>A3354710 . . . . . . . . . . .7-3, 7, 11, 36<br>A3354730 . . . . . . . . . . 7-3, 7, 11, 22,<br>. . . . . . . . . . . . . . . . . . . .23, 25, 36<br>A3354745 . . . . . . . . . . . . . .7-20, 36<br>AAO-_. . . . . . . . . . . . . . . . . . . . 5-7<br>ABC-_-R . . . . . . . . . . . . . . . . . . 3-9<br>ABC-V-_-R . . . . . . . . . . . . . . . . . 3-9<br>AC-_. . . . . . . . . . . . . . . . . . . . . 5-8<br>AD-_. . . . . . . . . . . . . . . . . . . . . 5-8<br>AGA-_. . . . . . . . . . . . . . . . . . . . 3-7<br>AGC-_-R . . . . . . . . . . . . . . . . . . 3-9<br>AGC-V-_-R . . . . . . . . . . . . . . . . . 3-9<br>AGW-_ . . . . . . . . . . . . . . . . . . . 3-8|BMM603-_. . . . . . . . . . . . . . . . . 8-6<br>BNQ21-_ . . . . . . . . . . . . . . . . . 10-8<br>BOOT-KCM. . . . . . . . . . . . . . . . . 2-3<br>BOOT-KDM . . . . . . . . . . . . . . . . 2-3<br>BPVM-_. . . . . . . . . . . . . . . . . . . 6-9<br>BQE . . . . . . . . . . . . . . . . . . . . 10-8<br>BQQ41-_ . . . . . . . . . . . . . . . . . 10-8<br>BRKT-ANGL . . . . . . . . . . . . . . 10-20<br>BRKT-FLT . . . . . . . . . . . . . . . . 10-20<br>BRKT-ND . . . . . . . . . . . . . . . . 10-20<br>BRKT-NDSCRW . . . . . . . . . . . . 10-20<br>BRKT-NDSCRW2 . . . . . . . . . . . 10-20<br>BRKT-NDSCRW3 . . . . . . . . . . . 10-20<br>BS . . . . . . . . . . . . . . . . . . 10-13, 15<br>BSPA_. . . . . . . . . . . . . . . . . . . 13-6<br>BSPA-FLUSHPLT_. . . . . . . . . . . . 13-7|CCP2B-_-_CF . . . . . . . . . . . . . 11-36<br>CCP2-CWK2 . . . . . . . . . . .1-14, 11-10<br>CCP2-FLC1-_ . . . . . . . . . . . . . 11-17<br>CCP2-FLC2-_ . . . . . . . . . . . . . 11-17<br>CCP2-FLR1_ . . . . . . . . . . . . . . 11-17<br>CCP2-FLR2_ . . . . . . . . . . . . . . 11-17<br>CCP2-H4X-_ . . . . . . . . . . . . 11-15, 44<br>CCP2-HEX . . . . . . . . . . . . . . . 11-18<br>CCP2-L2-1 . . . . . . . . . . . .1-14, 11-10<br>CCP2-L2-1A . . . . . . . . . . .1-14, 11-10<br>CCP2-L4-1 . . . . . . . . . . . .1-14, 11-10<br>CCP2-L4-1A . . . . . . . . . . .1-14, 11-10<br>CCP2-L4B-3 . . . . . . . . . . .1-14, 11-10<br>CCP2-L4B-3A . . . . . . . . . .1-14, 11-10<br>CCP2-MW1-3 . . . . . . . . . . . 11-13, 43|CEO-_ . . . . . . . . . . . . . . . . . . . . 5-7<br>CFP-_ . . . . . . . . . . . . . . . . . . . 15-3<br>CGL-_ . . . . . . . . . . . . . . . . . . . . 5-3<br>CH_J_. . . . . . . . . . . . . . . . . . . 8-28<br>CH14_ . . . . . . . . . . . . . . . . . . 8-16<br>CH14_DIU . . . . . . . . . . . . . . . . 4-37<br>CH14_DMSU-F . . . . . . . . . . . . . 4-37<br>CH14_DNIU . . . . . . . . . . . . . . . 4-37<br>CH14_DNU . . . . . . . . . . . . . . . 4-37<br>CH14_DU . . . . . . . . . . . . . . . . 4-37<br>CH14-_PS . . . . . . . . . . . . . . . . 8-16<br>CH141DNXU . . . . . . . . . . . . . . 4-37<br>CH143DNMSU-F . . . . . . . . . . . . 4-37<br>CH14-CTP . . . . . . . . . . . . . . . . 8-16<br>CH14-IP20 . . . . . . . . . . . . . . . . 4-37|CPB160-_. . . . . . . . . . . . . . . . . . 9-9<br>CPB162-_. . . . . . . . . . . . . . 9-6, 9, 13<br>CPDB-_ . . . . . . . . . . . . . . . 9-6, 9, 13<br>CPDB165. . . . . . . . . . . . . . . .9-9, 13<br>CVR_-CCM . . . . . . . . . . . . . . . . . 8-6<br>CVR_-CCM-QC . . . . . . . . . . . . . . 8-6<br>CVR_-J-60030 . . . . . . . . . . . . . . 8-32<br>CVR_-J-60060 . . . . . . . . . 8-18, 32, 34<br>CVR_-J-60100-M . . . . . . . . . .8-32, 34<br>CVR_-J-60200-M . . . . . . . . . .8-32, 34<br>CVR_-J-60400-M . . . . . . . . . .8-32, 34<br>CVR_-J-60600-M . . . . . . . . . . . . 8-32<br>CVR_-RH-25030 . . . . . . . . . . . . 8-19<br>CVR_-RH-25060 . . . . . . . 8-19, 25, 27<br>CVR_-RH-25100 . . . . . . . . . .8-20, 23|||
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
16-11
## **16 — Fuse and fuse block cross reference, and index**
## Catalog number index
For information on products not contained in this catalog, contact Customer Satisfaction, toll-free, at 855-287-7626 (855-BUSSMANN) between 7:00 a.m. — 6:00 p.m. Central time, M-F, or email BussCustSat@Eaton.com.
|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|
|---|---|---|---|---|
|CVR_-RH-25200 . . . . . . . . . .8-20, 23|ER12-800L3PB . . . . . . . . . . . . 11-85|ER4-800L3PB . . . . . . . . . . . . . 11-85|FL12K_ . . . . . . . . . . . . . . . . . . 7-34|GBB-_-R . . . . . . . . . . . . . . . . . 3-10|
|CVR_-RH-25400 . . . . . . . . . .8-20, 23|ER12-800N3PB . . . . . . . . . . . . 11-87|ER4-800N3PB . . . . . . . . . . . . . 11-87|FL3K_ . . . . . . . . . . . . . . . . . . . 7-34|GBB-V-_-R . . . . . . . . . . . . . . . . 3-10|
|CVR_-RH-25600 . . . . . . . . . .8-20, 23|ER12-80N_PB . . . . . . . . . . . . . 11-89|ER4-80N_PB . . . . . . . . . . . . . . 11-89|FL3T_ . . . . . . . . . . . . . . . . . . . 7-34|GDA-_. . . . . . . . . . . . . . . . . . . . 3-4|
|CVR_-RH-60030 . . . . . . . . . .8-19, 22|ER1-30J3PB . . . . . . . . . . . . . . 11-85|ER4P-100J3PB. . . . . . . . . . . . . 11-85|FLC- . . . . . . . . . . 11-58, 60, 62, 64, 66|GDB-_. . . . . . . . . . . . . . . . . . . . 3-3|
|CVR_-RH-60060 . . . . . 8-19, 22, 25, 27|ER1-30N3PB. . . . . . . . . . . . . . 11-87|ER4P-100N3PB . . . . . . . . . . . . 11-87|FLH_. . . . . . . . . . 11-58, 60, 62, 64, 66|GDC-_. . . . . . . . . . . . . . . . . . . . 3-5|
|CVR_-RH-60100 . . . . . . . . . .8-20, 23|ER1-400J3PB . . . . . . . . . . . . . 11-85|ER4P-16N_PB . . . . . . . . . . . . . 11-89|FLMC . . . . . . . . . 11-58, 60, 62, 64, 66|GF-_ . . . . . . . . . . . . . . . . . . . . . 5-8|
|CVR_-RH-60200 . . . . . . . . . .8-20, 23|ER1-400N3PB . . . . . . . . . . . . . 11-87|ER4P-200J3PB. . . . . . . . . . . . . 11-85|FLMR . . . . . . . . . 11-58, 60, 62, 64, 66|GG-_. . . . . . . . . . . . . . . . . . . . . 5-8|
|CVR_-RH-60400 . . . . . . . . . .8-20, 23|ER1-40N_PB . . . . . . . . . . . . . . 11-89|ER4P-200N3PB . . . . . . . . . . . . 11-87|FNA-_ . . . . . . . . . . . . . . . . . . . . 2-9|GH-_. . . . . . . . . . . . . . . . . . . . . 5-8|
|CVR_-RH-60600 . . . . . . . . . .8-20, 23|ER1-600J3PB . . . . . . . . . . . . . 11-85|ER4P-25N_PB . . . . . . . . . . . . . 11-89|FNM-_ . . . . . . . . . . . . . . . . . . . 2-6|GLD-_. . . . . . . . . . . . . . . . . . . . 2-8|
|CVR-CCM. . . . . . . . . . . . . . . 6-9, 8-6|ER1-600N3PB . . . . . . . . . . . . . 11-87|ER4P-30J3PB . . . . . . . . . . . . . 11-85|FNQ-_. . . . . . . . . . . . . . . . . . . . 2-7|GLP . . . . . . . . . . . . . . . . . . . . 5-15|
|CVRI-CCM . . . . . . . . . . . . . . 6-9, 8-6|ER1-60J3PB . . . . . . . . . . . . . . 11-85|ER4P-30N3PB . . . . . . . . . . . . . 11-87|FNQ-R-_ . . . . . . . . . . . . . . . . . . 1-6|GLQ-_. . . . . . . . . . . . . . . . . . . 2-10|
|DD-_ . . . . . . . . . . . . . . . . . . . . 5-8|ER1-60N3PB. . . . . . . . . . . . . . 11-87|ER4P-400J3PB. . . . . . . . . . . . . 11-85|FP-_ . . . . . . . . . . . . . . . . . . . . 15-3|GLR-_ . . . . . . . . . . . . . . . . . . . 2-11|
|DD1-J . . . . . . . . . . . . . . . . . . 10-16|ER1-63N_PB . . . . . . . . . . . . . . 11-89|ER4P-400N3PB . . . . . . . . . . . . 11-87|FRN-R-_. . . . . . . . . . . . . . . . . . 1-29|GMA-_-R . . . . . . . . . . . . . . . . . . 3-6|
|DD2HB-J . . . . . . . . . . . . . . . . 10-16|ER1-800L3PB . . . . . . . . . . . . . 11-85|ER4P-40N_PB . . . . . . . . . . . . . 11-89|FRN-R-_ID . . . . . . . . . . . . . . . . 1-29|GMA-V-_-R. . . . . . . . . . . . . . . . . 3-6|
|DD2-J . . . . . . . . . . . . . . . . . . 10-16|ER1-800N3PB . . . . . . . . . . . . . 11-87|ER4P-600J3PB. . . . . . . . . . . . . 11-85|FRS-R-_ . . . . . . . . . . . . . . . . . . 1-29|GMC-_-R . . . . . . . . . . . . . . . . . . 3-6|
|DD3-J . . . . . . . . . . . . . . . . . . 10-16|ER1-80N_PB . . . . . . . . . . . . . . 11-89|ER4P-600N3PB . . . . . . . . . . . . 11-87|FRS-R-_ID . . . . . . . . . . . . . . . . 1-29|GMC-V-_-R. . . . . . . . . . . . . . . . . 3-6|
|DEO-_. . . . . . . . . . . . . . . . . . . . 5-7|ER3R-100J3PB. . . . . . . . . . . . . 11-85|ER4P-60J3PB . . . . . . . . . . . . . 11-85|FSCVR. . . . . . . . . . . . . . . . . . . 8-10|GMD-_-R . . . . . . . . . . . . . . . . . . 3-7|
|DFJ-_ . . . . . . . . . . . . . . . . . . . . 4-4|ER3R-100N3PB . . . . . . . . . . . . 11-87|ER4P-60N3PB . . . . . . . . . . . . . 11-87|FT-_ . . . . . . . . . . . . . . . . . . . . 15-3|GMD-V-_-R. . . . . . . . . . . . . . . . . 3-7|
|DIR-0_ . . . . . . . .11-56, 58, 60, 62, 64,|ER3R-1200N3PB . . . . . . . . . . . 11-87|ER4P-63N_PB . . . . . . . . . . . . . 11-89|FWA-_A. . . . . . . . . . . . . . . . . . . 4-6|GMF-_. . . . . . . . . . . . . . . . . . . 2-11|
|. . . . . . . . . . . . . 66, 69, 73, 75, 77, 81|ER3R-16N_PB . . . . . . . . . . . . . 11-89|ER4P-800L3PB . . . . . . . . . . . . 11-85|FWA-_A10F . . . . . . . . . . . . . . . 4-22|GMQ-_ . . . . . . . . . . . . . . . . . . 2-10|
|DOOR-508 . . . . . . . . . . . . . . . 11-81|ER3R-200J3PB. . . . . . . . . . . . . 11-85|ER4P-800N3PB . . . . . . . . . . . . 11-87|FWA-_A21F . . . . . . . . . . . . . . . 4-22|GMT-_A. . . . . . . . . . . . . . . . . 14-11|
|DRA-1. . . . . . . . . . . . . . . . . . . 15-4<br>DRL35MM_ . . . . . . . . . . . . . . 10-20<br>EC-250 . . . . . . . . . . . . . . . . . . 4-21<br>EC-600 . . . . . . . . . . . . . . . . . . 4-21|ER3R-200N3PB . . . . . . . . . . . . 11-87<br>ER3R-25N_PB . . . . . . . . . . . . . 11-89<br>ER3R-30J3PB . . . . . . . . . . . . . 11-85<br>ER3R-30N3PB . . . . . . . . . . . . . 11-87|ER4P-80N_PB . . . . . . . . . . . . . 11-89<br>ER4X-100J3PB. . . . . . . . . . . . . 11-85<br>ER4X-100N3PB . . . . . . . . . . . . 11-87<br>ER4X-1200N3PB . . . . . . . . . . . 11-87|FWA-_AH. . . . . . . . . . . . . . . . . . 4-5<br>FWA-_B. . . . . . . . . . . . . . . . . . . 4-6<br>FWC-_A10F . . . . . . . . . . . . . . . 4-26<br>FWH-_A . . . . . . . . . . . . . . . . . . 4-8|GMT-A . . . . . . . . . . . . . . . . . 14-11<br>GND-_-_ . . . . . . . . . . . . . . . . 11-82<br>GRF-_ . . . . . . . . . . . . . . . . . . . 2-11<br>H12-03_ . . . . . . . . . . . .11-62, 64, 66|
|ECAP1P. . . . . . . . . . . . . . . . . . 8-10|ER3R-400J3PB. . . . . . . . . . . . . 11-85|ER4X-16N_PB . . . . . . . . . . . . . 11-89|FWH-_A14F . . . . . . . . . . . . . . . 4-25|H12-05_ . . . . . . . . . . . .11-56, 58, 60|
|ED-_. . . . . . . . . . . . . . . . . . . . . 5-8<br>EF-_ . . . . . . . . . . . . . . . . . . . . . 5-8<br>EFS-_ . . . . . . . . . . . . . . . . . . . . 5-8<br>ER1-100J3PB . . . . . . . . . . . . . 11-85<br>ER1-100N3PB . . . . . . . . . . . . . 11-87<br>ER1-1200N3PB . . . . . . . . . . . . 11-87|ER3R-400N3PB . . . . . . . . . . . . 11-87<br>ER3R-40N_PB . . . . . . . . . . . . . 11-89<br>ER3R-600J3PB. . . . . . . . . . . . . 11-85<br>ER3R-600N3PB . . . . . . . . . . . . 11-87<br>ER3R-60J3PB . . . . . . . . . . . . . 11-85<br>ER3R-60N3PB . . . . . . . . . . . . . 11-87|ER4X-200J3PB. . . . . . . . . . . . . 11-85<br>ER4X-200N3PB . . . . . . . . . . . . 11-87<br>ER4X-25N_PB . . . . . . . . . . . . . 11-89<br>ER4X-30J3PB . . . . . . . . . . . . . 11-85<br>ER4X-30N3PB . . . . . . . . . . . . . 11-87<br>ER4X-400J3PB. . . . . . . . . . . . . 11-85|FWH-_A6F . . . . . . . . . . . . . . . . 4-24<br>FWH-_B. . . . . . . . . . . . . . . . . . . 4-8<br>FWH5-_A6F . . . . . . . . . . . . . . . 4-24<br>FWJ-_A . . . . . . . . . . . . . . . . . . 4-13<br>FWJ-_A14F. . . . . . . . . . . . . . . . 4-33<br>FWK-_20F . . . . . . . . . . . . . . . . 4-32|H12X-03_ . . . . . . . . . . . . . . . 11-75<br>H15-H-1 . . . . . . . . . . . . . . . . . 3-12<br>H15-V-1. . . . . . . . . . . . . . . . . . 3-12<br>H4X-01_ . . . . . . . . . . . . . . 11-73, 81<br>H4X-02_ . . . . . . . . . . . . . . . . 11-81<br>H4X-03_ . . . . . . . . . . . . . . 11-73, 81|
|ER1-16N_PB . . . . . . . . . . . . . . 11-89<br>ER1-200J3PB . . . . . . . . . . . . . 11-85<br>ER1-200N3PB . . . . . . . . . . . . . 11-87|ER3R-63N_PB . . . . . . . . . . . . . 11-89<br>ER3R-800L3PB . . . . . . . . . . . . 11-85<br>ER3R-800N3PB . . . . . . . . . . . . 11-87|ER4X-400N3PB . . . . . . . . . . . . 11-87<br>ER4X-40N_PB . . . . . . . . . . . . . 11-89<br>ER4X-600J3PB. . . . . . . . . . . . . 11-85|FWK-_A25F . . . . . . . . . . . . . . . 4-32<br>FWL-_A20F . . . . . . . . . . . . . . . 4-34<br>FWL-_A20FI . . . . . . . . . . . . . . . 4-34|H4X-04_ . . . . . . . . . . . . . . . . 11-56<br>H4X-05_ . . . . . . . . . . . .11-56, 58, 60<br>H4X-06_ . . . . . . . . . . . 62, 64, 66, 75|
|ER12-100J3PB. . . . . . . . . . . . . 11-85<br>ER12-100N3PB . . . . . . . . . . . . 11-87<br>ER12-1200N3PB . . . . . . . . . . . 11-87<br>ER12-16N_PB . . . . . . . . . . . . . 11-89|ER3R-80N_PB . . . . . . . . . . . . . 11-89<br>ER4-100J3PB . . . . . . . . . . . . . 11-85<br>ER4-100N3PB . . . . . . . . . . . . . 11-87<br>ER4-1200N3PB . . . . . . . . . . . . 11-87|ER4X-600N3PB . . . . . . . . . . . . 11-87<br>ER4X-60J3PB . . . . . . . . . . . . . 11-85<br>ER4X-60N3PB . . . . . . . . . . . . . 11-87<br>ER4X-63N_PB . . . . . . . . . . . . . 11-89|FWP-_A. . . . . . . . . . . . . . . . . . 4-11<br>FWP-_A14F . . . . . . . . . . . . . . . 4-28<br>FWP-_A14FI . . . . . . . . . . . . . . . 4-28<br>FWP-_A22F . . . . . . . . . . . . . . . 4-30|H4X-07_ . . . . . . . . . . . . . . 11-69, 77<br>H4X-08_ . . . . . . . . . . . . . . . . 11-77<br>H79-_ . . . . . . .11-56, 58, 60, 64, 67, 69<br>HBH-I . . . . . . . . . . . . . . . . . . . 3-13|
|ER12-200J3PB. . . . . . . . . . . . . 11-85<br>ER12-200N3PB . . . . . . . . . . . . 11-87<br>ER12-25N_PB . . . . . . . . . . . . . 11-89<br>ER12-30J3PB . . . . . . . . . . . . . 11-85<br>ER12-30N3PB . . . . . . . . . . . . . 11-87|ER4-16N_PB . . . . . . . . . . . . . . 11-89<br>ER4-200J3PB . . . . . . . . . . . . . 11-85<br>ER4-200N3PB . . . . . . . . . . . . . 11-87<br>ER4-25N_PB . . . . . . . . . . . . . . 11-89<br>ER4-30J3PB . . . . . . . . . . . . . . 11-85|ER4X-800L3PB . . . . . . . . . . . . 11-85<br>ER4X-800N3PB . . . . . . . . . . . . 11-87<br>ER4X-80N_PB . . . . . . . . . . . . . 11-89<br>ESD-_ . . . . . . . . . . . . . . . . . . . . 5-7<br>FBI . . . . . . . . . . . . . . . . . . . . . 3-13|FWP-_A22FI . . . . . . . . . . . . . . . 4-30<br>FWP-_B . . . . . . . . . . . . . . . . . . 4-11<br>FWP-_G10F . . . . . . . . . . . . . . . 4-27<br>FWP-_G14F . . . . . . . . . . . . . . . 4-29<br>FWP-_G14FI . . . . . . . . . . . . . . . 4-29|HBH-M . . . . . . . . . . . . . . . . . . 3-13<br>HBV-I . . . . . . . . . . . . . . . . . . . 3-13<br>HBV-M . . . . . . . . . . . . . . . . . . 3-13<br>HBW-I . . . . . . . . . . . . . . . . . . . 3-13<br>HBW-M . . . . . . . . . . . . . . . . . . 3-13|
|ER12-400J3PB. . . . . . . . . . . . . 11-85<br>ER12-400N3PB . . . . . . . . . . . . 11-87<br>ER12-40N_PB . . . . . . . . . . . . . 11-89|ER4-30N3PB. . . . . . . . . . . . . . 11-87<br>ER4-400J3PB . . . . . . . . . . . . . 11-85<br>ER4-400N3PB . . . . . . . . . . . . . 11-87|FBM . . . . . . . . . . . . . . . . . . . . 3-13<br>FCF_RN. . . . . . . . . . . . . . . . . . 1-10<br>FEH . . . . . . . . . . . . . 5-12, 6-11, 8-40|FWP-_G22F . . . . . . . . . . . . . . . 4-31<br>FWP-_G22FI . . . . . . . . . . . . . . . 4-31<br>FWS-_A20F . . . . . . . . . . . . . . . 4-35|HCL-NL-1. . . . . . . . . . . . . 7-8, 13, 18<br>HEB-_ . . . . . . . . . . . . . . . . . . . 8-51<br>HEC-_ . . . . . . . . . . . . . . . . . . . 8-49|
|ER1-25N_PB . . . . . . . . . . . . . . 11-89|ER4-40N_PB . . . . . . . . . . . . . . 11-89|FEH1500 . . . . . . . . . . . . . . . . . 6-10|FWS-_A20FI . . . . . . . . . . . . . . . 4-35|HEG-_. . . . . . . . . . . . . . . . . . . 8-49|
|ER12-600J3PB. . . . . . . . . . . . . 11-85<br>ER12-600N3PB . . . . . . . . . . . . 11-87<br>ER12-60J3PB . . . . . . . . . . . . . 11-85<br>ER12-60N3PB . . . . . . . . . . . . . 11-87<br>ER12-63N_PB . . . . . . . . . . . . . 11-89|ER4-600J3PB . . . . . . . . . . . . . 11-85<br>ER4-600N3PB . . . . . . . . . . . . . 11-87<br>ER4-60J3PB . . . . . . . . . . . . . . 11-85<br>ER4-60N3PB. . . . . . . . . . . . . . 11-87<br>ER4-63N_PB . . . . . . . . . . . . . . 11-89|FF-_ . . . . . . . . . . . . . . . . . . . . . 5-8<br>FG-_ . . . . . . . . . . . . . . . . . . . . . 5-8<br>FL11H_ . . . . . . . . . . . . . . . . . . 7-34<br>FL11K_ . . . . . . . . . . . . . . . . . . 7-34<br>FL11T_ . . . . . . . . . . . . . . . . . . 7-34|FWX-__AH . . . . . . . . . . . . . . . . . 4-7<br>FWX-_A. . . . . . . . . . . . . . . . . . . 4-7<br>FWX-_A14F . . . . . . . . . . . . . . . 4-23<br>G30060-_ . . . . . . . . . . . . . . . . 8-15<br>GBA-_. . . . . . . . . . . . . . . . . . . . 2-8|HEH-_. . . . . . . . . . . . . . . . . . . 8-49<br>HEJ-_ . . . . . . . . . . . . . . . . . . . 8-49<br>HET . . . . . . . . . . . . . . . 8-49, 51, 53<br>HEX-_ . . . . . . . . . . . . . . . . . . . 8-53<br>HEY-_ . . . . . . . . . . . . . . . . . . . 8-53|
16-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
**Fuse and fuse block cross reference, and index — 16**
## Catalog number index
For information on products not contained in this catalog, contact Customer Satisfaction, toll-free, at 855-287-7626 (855-BUSSMANN) between 7:00 a.m. — 6:00 p.m. Central time, M-F, or email BussCustSat@Eaton.com.
|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|
|---|---|---|---|---|
|HEZ-_ . . . . . . . . . . . . . . . . . . . 8-52|HRK-R . . . . . . . . . . . . . . . . . . . 8-48|JM60400-_. . . . . . . . . . . . . . . . 8-32|KEW . . . . . . . . . . . . . . . . . . . . . 2-3|NDN_ . . . . . . . . . . . . . . . . . .10-2, 3|
|HFA-_ . . . . . . . . . . . . . . . . . . . 8-46|HTB-_- . . . . . . . . . . . . . . . . . . 8-41|JM60400-_MW_ . . . . . . . . . . . . 8-34|KEX . . . . . . . . . . . . . . . . . . . . . 2-3|NDNF1-WH . . . . . . . . . . . . . . . 8-11|
|HFB-_ . . . . . . . . . . . . . . . . . . . 8-47|HTC-140M . . . . . . . . . . . . . . . . 3-14|JM60600-_. . . . . . . . . . . . . . . . 8-32|KFH-A. . . . . . . . . . . . . . . . . . . . 2-3|NFT_ . . . . . . . . . . . . . . . . . . . 10-4|
|HH_ . . . . . . . . . . . . . . . . . . . . 8-48|HTC-150M . . . . . . . . . . . . . . . . 3-14|JM70100-_. . . . . . . . . . . . . . . . 8-18|KFM . . . . . . . . . . . . . . . . . . . . . 2-3|NFTA . . . . . . . . . . . . . . . . . . 10-20|
|HH2 . . . . . . . . . . . . . . . . . . . . 2-14|HTC-15M . . . . . . . . . . . . . . . . . 3-14|JM70100-_CR . . . . . . . . . . . . . . 4-36|KFT . . . . . . . . . . . . . . . . . . . . . 2-3|NITD-_ . . . . . . . . . . . . . . . . . . . 5-7|
|HHB-_. . . . . . . . . . . . . . . . . . . 8-47|HTC-200M . . . . . . . . . . . . . . . . 3-14|JM70100-_MW14 . . . . . . . . . . . 8-18|KFZ . . . . . . . . . . . . . . . . . . . . . 2-3|NNB . . . . . . . . . . . . . . . . . . . . 15-3|
|HHC . . . . . . . . . . . . . . . . . . . . 2-14|HTC-210M . . . . . . . . . . . . . . . . 3-14|JN1 . . . . . . . . . . . . . . . . . 10-2, 3, 6|KIG. . . . . . . . . . . . . . . . . . . . . . 2-3|NNB-R. . . . . . . . . . . . . . . . . . . 15-3|
|HHD. . . . . . . . . . . . . . . . . . . . 2-14|HTC-60M . . . . . . . . . . . . . . . . . 3-12|JN2 . . . . . . . . . . . . . . . . . . . . 10-4|KIT-6POLE . . . . . . . . . . . . . . . 11-82|NNC . . . . . . . . . . . . . . . . . . . . 15-3|
|HHF . . . . . . . . . . . . . . . . . . . . 2-14|HVA_ . . . . . . . . . . . . . . . . . . . 7-30|JN3 . . . . . . . . . . . . . . . . . 10-4, 6, 7|KLM-_. . . . . . . . . . . . . . . . . . . . 2-6|NO.1. . . . . . . . . . . . . . . . . . . . 15-4|
|HHG . . . . . . . . . . . . . . . . . . . . 2-14|HVB_ . . . . . . . . . . . . . . . . . . . 7-30|JN4 . . . . . . . . . . . . . . . . . . .10-2, 7|KLU-_ . . . . . . . . . . . . . . . . . . . 1-24|NO.2. . . . . . . . . . . . . . . . . . . . 15-4|
|HHL . . . . . . . . . . . . . . . . . . . . 2-14|HVJ_. . . . . . . . . . . . . . . . . . . . 7-30|JN512 . . . . . . . . . . . . . . . . . . . 10-4|KPF . . . . . . . . . . . . . . . . . . . . . 2-3|NO.213 . . . . . . . . . . . . . . . . . . 15-2|
|HHM. . . . . . . . . . . . . . . . . . . . 2-14|HVL_ . . . . . . . . . . . . . . . . . . . 7-30|JNDN3 . . . . . . . . . . . . . . . . . . 10-2|KQO . . . . . . . . . . . . . . . . . . . . . 2-3|NO.213-R. . . . . . . . . . . . . . . . . 15-2|
|HHR . . . . . . . . . . . . . . . . . . . . 2-14|HVR . . . . . . . . . . . . . . . . . . . . 7-30|JNSE3 . . . . . . . . . . . . . . . . . . . 10-5|KQT . . . . . . . . . . . . . . . . . . . . . 2-3|NO.216 . . . . . . . . . . . . . . . . . . 15-2|
|HHS . . . . . . . . . . . . . . . . . . . . 2-14|HVT_ . . . . . . . . . . . . . . . . . . . 7-30|JNSS3 . . . . . . . . . . . . . . . . . . . 10-5|KQV . . . . . . . . . . . . . . . . . . . . . 2-3|NO.216-R. . . . . . . . . . . . . . . . . 15-2|
|HHT . . . . . . . . . . . . . . . . . . . . 8-46|HVU_ . . . . . . . . . . . . . . . . . . . 7-30|JP60030-3_ . . . . . . . . . . . . . . . 8-30|KRP-C-_SP . . . . . . . . . . . . . . . . 1-22|NO.226 . . . . . . . . . . . . . . . . . . 15-2|
|HHU . . . . . . . . . . . . . . . . . . . . 2-14|HVW_ . . . . . . . . . . . . . . . . . . . 7-30|JT60030 . . . . . . . . . . . . . . . . . 8-29|KRP-CL-_ . . . . . . . . . . . . . . . . . 1-23|NO.226-R . . . . . . . . . . . . . . . . 15-2|
|HHV . . . . . . . . . . . . . . . . . . . . 2-14|HVX_ . . . . . . . . . . . . . . . . . . . 7-30|JT60060 . . . . . . . . . . . . . . . . . 8-29|KT_ . . . . . . . . . . . . . . . . . . . . 10-7|NO.242-R. . . . . . . . . . . . . . . . . 15-2|
|HHX . . . . . . . . . . . . . . . . . . . . 2-14|J101 . . . . . . . . . . . . . . . . . . . 10-11|JTN60030 . . . . . . . . . . . . . . . . 8-29|KTK-_ . . . . . . . . . . . . . . . . . . . . 2-5|NO.2621 . . . . . . . . . . . . . . . . . 15-2|
|HJL . . . . . . . . . . . . . . . . . . . . 8-42|J-13 . . . . . . . . . . . . . . . . . . . . 15-2|JTN60060 . . . . . . . . . . . . . . . . 8-29|KTK-R-_. . . . . . . . . . . . . . . . . . . 1-7|NO.2621-R . . . . . . . . . . . . . . . . 15-2|
|HK_ . . . . . . . . . . . . . . . . . . . . 8-42|J15188 . . . . . . . . . . . . . . . . . . 10-6|JU12. . . . . . . . . . . . . . . . . . . 10-19|KTN-R-_. . . . . . . . . . . . . . . . . . 1-27|NO.263 . . . . . . . . . . . . . . . . . . 15-2|
|HKP-_ . . . . . . . . . . . . . . . . . . . 8-42|J-16 . . . . . . . . . . . . . . . . . . . . 15-2|JV-L . . . . . . . . . . . . . . . . . .8-16, 17|KTS-R-_ . . . . . . . . . . . . . . . . . . 1-27|NO.263-R. . . . . . . . . . . . . . . . . 15-2|
|HLD-_. . . . . . . . . . . . . . . . . . . 8-43|J201 . . . . . . . . . . . . . . . . . . . 10-13|KAC-_ . . . . . . . . . . . . . . . . . . . . 4-9|KTU-_ . . . . . . . . . . . . . . . . . . . 1-23|NO.2641 . . . . . . . . . . . . . . . . . 15-2|
|HLQ-_. . . . . . . . . . . . . . . . . . . 2-10|J-21 . . . . . . . . . . . . . . . . . . . . 15-2|KAD . . . . . . . . . . . . . . . . . . . . 10-7|KU_ . . . . . . . . . . . . . . . . . . . 10-19|NO.2641-R . . . . . . . . . . . . . . . . 15-2|
|HLR . . . . . . . . . . . . . . . . . . . . 2-11|J-26 . . . . . . . . . . . . . . . . . . . . 15-2|KAZ . . . . . . . . . . . . . . . . . . . . . 2-9|LP-CC-_. . . . . . . . . . . . . . . . . . . 1-5|NO.2642 . . . . . . . . . . . . . . . . . 15-2|
|HLR-2A . . . . . . . . . . . . . . . . . . 2-11|J301 . . . . . . . . . . . . . . . . . . . 10-15|KBC-_ . . . . . . . . . . . . . . . . . . . 4-10|LPJ-_SP . . . . . . . . . . . . . . . . . . 1-19|NO.2661 . . . . . . . . . . . . . . . . . 15-2|
|HLS_. . . . . . . . . . . . . . . . . . . 14-11|J-41 . . . . . . . . . . . . . . . . . . . . 15-2|KCA . . . . . . . . . . . . . . . . . . . . . 2-3|LPJ-_SPI. . . . . . . . . . . . . . . . . . 1-19|NO.2661-R . . . . . . . . . . . . . . . . 15-2|
|HLT_. . . . . . . . . . . . . . . . . . . 14-11|J-42 . . . . . . . . . . . . . . . . . . . . 15-2|KCB . . . . . . . . . . . . . . . . . . . . . 2-3|LPN-RK-_SP . . . . . . . . . . . . . . . 1-24|NO.2662 . . . . . . . . . . . . . . . . . 15-2|
|HM_. . . . . . . . . . . . . . . . . . . . 8-48|J-62 . . . . . . . . . . . . . . . . . . . . 15-2|KCC . . . . . . . . . . . . . . . . . . . . . 2-3|LPN-RK-_SPI . . . . . . . . . . . . . . . 1-24|NO.2662-R . . . . . . . . . . . . . . . . 15-2|
|HM25030-_ . . . . . . . . . . . . . . . 8-19|J-63 . . . . . . . . . . . . . . . . . . . . 15-2|KCD . . . . . . . . . . . . . . . . . . . . . 2-3|LPS-RK-_SP . . . . . . . . . . . . . . . 1-24|NO.2664 . . . . . . . . . . . . . . . . . 15-2|
|HM25060-_ . . . . . . . . . . . . . . . 8-19|J-64 . . . . . . . . . . . . . . . . . . . . 15-2|KCE . . . . . . . . . . . . . . . . . . . . . 2-3|LPS-RK-_SPI . . . . . . . . . . . . . . . 1-24|NO.2664-R . . . . . . . . . . . . . . . . 15-2|
|HM25060-_MW_ . . . . . . . . . . . . 8-25|JCH-_R . . . . . . . . . . . . . . . . . . 7-22|KCF . . . . . . . . . . . . . . . . . . . . . 2-3|LUG_-_ . . . . . . . . . . 11-66, 69, 75, 77|NO.4. . . . . . . . . . . . . . . . . . . . 15-4|
|HM25100-_ . . . . . . . . . . . . . . . 8-20|JCK-_R . . . . . . . . . . . . . . . . . . 7-22|KCH . . . . . . . . . . . . . . . . . . . . . 2-3|MAI . . . . . . . . . . . . . . . . . . . . 4-21|NO.5. . . . . . . . . . . . . . . . . . . . 15-4|
|HM25200-_ . . . . . . . . . . . . . . . 8-20|JCK-A-_R . . . . . . . . . . . . . . . . . 7-22|KCJ. . . . . . . . . . . . . . . . . . . . . . 2-3|MAX-_. . . . . . . . . . . . . . . . . . . 2-13|NO.6. . . . . . . . . . . . . . . . . . . . 15-4|
|HM25400-_ . . . . . . . . . . . . . . . 8-20<br>HM25600-_ . . . . . . . . . . . . . . . 8-20<br>HM60030-_ . . . . . . . . . . . . . . . 8-19<br>HM60060-_ . . . . . . . . . . . . . . . 8-19<br>HM60060-_MW_ . . . . . . . . . . . . 8-25|JCK-B-_R . . . . . . . . . . . . . . . . . 7-22<br>JCL-_R. . . . . . . . . . . . . . . . . . . 7-23<br>JCL-A-_R . . . . . . . . . . . . . . . . . 7-23<br>JCL-B-_R . . . . . . . . . . . . . . . . . 7-23<br>JCW-_. . . . . . . . . . . . . . . . . . . 7-26|KCM . . . . . . . . . . . . . . . . . . . . . 2-3<br>KCR . . . . . . . . . . . . . . . . . . . . . 2-3<br>KCS . . . . . . . . . . . . . . . . . . . . . 2-3<br>KCV . . . . . . . . . . . . . . . . . . . . . 2-3<br>KCY . . . . . . . . . . . . . . . . . . . . . 2-3|MAX-FHID . . . . . . . . . . . . . . . . 2-14<br>MB-_ . . . . . . . . . . . . . . . . . . . 1-35<br>MBI . . . . . . . . . . . . . . . . . . . . 4-21<br>MC-250. . . . . . . . . . . . . . . . . . 4-21<br>MC-600. . . . . . . . . . . . . . . . . . 4-21|NO.616 . . . . . . . . . . . . . . . . . . 15-2<br>NO.616-R. . . . . . . . . . . . . . . . . 15-2<br>NO.626 . . . . . . . . . . . . . . . . . . 15-2<br>NO.626-R. . . . . . . . . . . . . . . . . 15-2<br>NO.642-R. . . . . . . . . . . . . . . . . 15-2|
|HM60100-_ . . . . . . . . . . . . . . . 8-20|JCX-_E . . . . . . . . . . . . . . . . . . . 7-3|KCZ . . . . . . . . . . . . . . . . . . . . . 2-3|MDA-_-R . . . . . . . . . . . . . . . . . 3-11|NO.663 . . . . . . . . . . . . . . . . . . 15-2|
|HM60200-_ . . . . . . . . . . . . . . . 8-20|JCY-_E. . . . . . . . . . . . . . . . . . . . 7-5|KDA . . . . . . . . . . . . . . . . . . . . . 2-3|MDA-V-_-R. . . . . . . . . . . . . . . . 3-11|NO.663-R. . . . . . . . . . . . . . . . . 15-2|
|HM60400-_ . . . . . . . . . . . . . . . 8-20|JF1. . . . . . . . . . . . . . . . . . . . . 8-11|KDB . . . . . . . . . . . . . . . . . . . . . 2-3|MDL-_-R . . . . . . . . . . . . . . . . . 3-10|NO.7. . . . . . . . . . . . . . . . . . . . 15-4|
|HM60600-_ . . . . . . . . . . . . . . . 8-20|JJN-_ . . . . . . . . . . . . . . . . . . . 1-31|KDC . . . . . . . . . . . . . . . . . . . . . 2-3|MDL-V-_-R . . . . . . . . . . . . . . . . 3-10|NO.8. . . . . . . . . . . . . . . . . . . . 15-4|
|HPC-D. . . . . . . . . . . . . . . . . . . 8-43|JJS-_. . . . . . . . . . . . . . . . . . . . 1-31|KDD . . . . . . . . . . . . . . . . . . . . . 2-3|MDQ--R. . . . . . . . . . . . . . . . . . 3-11|NON-_ . . . . . . . . . . . . . . . . . . 1-21|
|HPD . . . . . . . . . . . . . . . . . . . . 8-44|JKS-_ . . . . . . . . . . . . . . . . . . . 1-20|KDE . . . . . . . . . . . . . . . . . . . . . 2-3|MDQ-V-_-R . . . . . . . . . . . . . . . 3-11|NOS-_. . . . . . . . . . . . . . . . . . . 1-21|
|HPF-_ . . . . . . . . . . . . . . . . . . . 8-43|JKS-_-700 . . . . . . . . . . . . . . . . 5-11|KDF . . . . . . . . . . . . . . . . . . . . . 2-3|MIC-_ . . . . . . . . . . . . . . . . . . . . 2-8|NRA . . . . . . . . . . . . . . . . . . . 10-20|
|HPG-_. . . . . . . . . . . . . . . . . . . 8-44|JM60030-_. . . . . . . . . . . . . . . . 8-32|KDH . . . . . . . . . . . . . . . . . . . . . 2-3|MIS-_ . . . . . . . . . . . . . . . . . . . . 2-9|NSD-_. . . . . . . . . . . . . . . . . . . . 5-7|
|HPM-_ . . . . . . . . . . . . . . . . . . 8-44|JM60030-_MW_ . . . . . . . . . . . . 8-34|KDJ . . . . . . . . . . . . . . . . . . . . . 2-3|MT12-1-2. . . . . . . . . .10-2, 3, 4, 5, 6, 7|NSE3-_ . . . . . . . . . . . . . . . . . . 10-5|
|HPS-_ . . . . . . . . . . . . . . . . . . . 8-45|JM60060-_. . . . . . . . . . . . . . . . 8-32|KDM. . . . . . . . . . . . . . . . . . . . . 2-3|MTC6 . . . . . . . . . . . . . . . . . .10-2, 7|NSS3-_ . . . . . . . . . . . . . . . . . . 10-5|
|HPS2 . . . . . . . . . . . . . . . . . . . 8-45|JM60060-_MW_ . . . . . . . . . . . . 8-34|KDP . . . . . . . . . . . . . . . . . . . . . 2-3|MTMU_. . . . . . . . . . . . . . . . . 10-19|NTN-R-_ . . . . . . . . . . . . . . . . . 15-3|
|HPV-D15V-4A . . . . . . . . . . . . . . . 6-4|JM60100-_. . . . . . . . . . . . . . . . 8-32|KDR . . . . . . . . . . . . . . . . . . . . . 2-3|MV055F_. . . . . . . . . . . . . . . . . . 7-5|NTRL-_-_ . . . . . . . . . . . . . . . . 11-82|
|HPV-DV-_A . . . . . . . . . . . . . . . . 6-4|JM60100-_MW_ . . . . . . . . . . . . 8-34|KDT . . . . . . . . . . . . . . . . . . . . . 2-3|MV155F_. . . . . . . . . . . . . . . . . 7-15|NTS-R-_. . . . . . . . . . . . . . . . . . 15-3|
|HR_ . . . . . . . . . . . . . . . . . . . . 8-48|JM60200-_. . . . . . . . . . . . . . . . 8-32|KDU . . . . . . . . . . . . . . . . . . . . . 2-3|N512-_ . . . . . . . . . . . . . . . . . . 10-4|NUC . . . . . . . . . . . . . . . . . . . 10-19|
|HR60060-_MW_ . . . . . . . . . . . . 8-27|JM60200-_MW_ . . . . . . . . . . . . 8-34|KDY . . . . . . . . . . . . . . . . . . . . . 2-3|NC3-_ . . . . . . . . . . . . . . . . . . . 10-5|NUE . . . . . . . . . . . . . . . . . . . 10-19|
Eaton.com/bussmannseries
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
16-13
**16 — Fuse and fuse block cross reference, and index**
## Catalog number index
For information on products not contained in this catalog, contact Customer Satisfaction, toll-free, at 855-287-7626 (855-BUSSMANN) between 7:00 a.m. — 6:00 p.m. Central time, M-F, or email BussCustSat@Eaton.com.
|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|Catalog no.<br>Page|
|---|---|---|---|---|
|NUM_. . . . . . . . . . . . . . . . . . 10-19|PWR50MM. . . . . . . . . . . . . . . . 8-10|RM25030-_ . . . . . . . . . . . . . . . 8-22|SD3-D-PV . . . . . . . . . . . . . . . . 6-11|TB300-_ . . . . . . . . . . . . . . . . 10-14|
|OJ_ . . . . . . . . . . . . 10-11, 13, 15, 18|QC_ . . . . . . . . . . . . . . .10-11, 13, 15|RM25060-_ . . . . . . . . . . . . . . . 8-22|SD3-PB . . . . . . . . . . . . . . 5-12, 8-40|TB345-_ . . . . . . . . . . . . . . . . 10-14|
|OPM-1038_ . . . . . . . . . . . . . . . 8-12|QC_-J . . . . . . . . . . . . . .10-11, 13, 15|RM25060-_MW_ . . . . . . . . . . . . 8-27|SD3-SK . . . . . . . . . . . . . . 5-12, 8-40|TB400 . . . . . . . . . . . . . . . . . . 10-18|
|OPM-NG-S_ . . . . . . . . . . . . . . . 8-13|QSCP . . . . . . . . . . . . . . . . . . . 12-2|RM25100-_ . . . . . . . . . . . . . . . 8-23|SD4-D. . . . . . . . . . . . . . . . . . . 8-40|TC-_ . . . . . . . . . . . . . . . . . . . . 1-34|
|OSD-_. . . . . . . . . . . . . . . . . . . . 5-7|RD1000-3 . . . . . . . . . . . . . 11-71, 72|RM25200-_ . . . . . . . . . . . . . . . 8-23|SD4-S . . . . . . . . . . . . . . . . . . . 5-12|TCF_. . . . . . . . . . . . . . . . . . . . . 1-8|
|P . . . . . . . . . . . . . . . . . . . . . 10-13|RD1000-4 . . . . . . . . . . . . . 11-71, 72|RM25400-_ . . . . . . . . . . . . . . . 8-23|SD4-S1600. . . . . . . . . . . . . . . . 8-40|TCF_RN. . . . . . . . . . . . . . . . . . . 1-8|
|P-_ . . . . . . . . . . . . . . . . . . . . . 1-34|RD100-3 . . . . . . . . . . . . . . 11-71, 72|RM25600-_ . . . . . . . . . . . . . . . 8-23|SDL-_ . . . . . . . . . . . . 5-12, 6-11, 8-40|TCFH_N. . . . . . . . . . . . . . . . . . 1-12|
|PCT . . . . . . . . . . . . . . . . . . . 14-11|RD100-3-SCCR . . . . . . . . . . 11-71, 72|RM60030-_ . . . . . . . . . . . . . . . 8-22|SFC-_ . . . . . . . . . . . . . . . . . . . 15-4|TCFH_NW . . . . . . . . . . . . . . . . 1-12|
|PDB_ . . . . . . . . . . . . . . . . . . . . 9-6|RD1200-3 . . . . . . . . . . . . . 11-71, 72|RM60060-_ . . . . . . . . . . . . . . . 8-22|SH1-_ . . . . . . . . . . . . . . . . . . 11-56|TD00-D . . . . . . . . . . . . . . 5-12, 8-40|
|PDBFS_. . . . . . . . . . . . . . . . . . . 9-3|RD1200-4 . . . . . . . . . . . . . 11-71, 72|RM60100-_ . . . . . . . . . . . . . . . 8-23|SH2-_ . . . . . . . . . . . . . . . . . . 11-56|TD00-IP20 . . . . . . . . . . . . . . . . 5-12|
|PF1-_ . . . . . . . . . . . . . . . . .8-11, 15|RD16-3-508 . . . . . . . . . . . . . . 11-79|RM60200-_ . . . . . . . . . . . . . . . 8-23|SH3-_ . . . . . . . . . . . . . . . . 11-73, 81|TD1-D. . . . . . . . . . . . . . . 5-12, 8-40|
|PLU_. . . . . . . . . . . . . . . . . . . . 10-6|RD200-3 . . . . . . . . . . . . . . 11-71, 72|RM60400-_ . . . . . . . . . . . . . . . 8-23|SH4-_ . . . . . . . . . . . . . . . . 11-73, 81|TD1-D-PV . . . . . . . . . . . . . . . . 6-11|
|PMP-_. . . . . . . . . . . . . . . . . . . 12-5|RD200-4 . . . . . . . . . . . . . . 11-71, 72|RM60600-_ . . . . . . . . . . . . . . . 8-23|SH5-_ . . . . . . . . . 11-58, 60, 62, 64, 66|TD1-IP20 . . . . . . . . . . . . . . . . . 5-12|
|POLE-_ . . . . . . . . . . . . . . . 11-82, 90|RD25-3-508 . . . . . . . . . . . . . . 11-79|RS_ . . . . . . . . . . . . . . . . . . . . 5-15|SH6-_ . . . . . . . . . . . . . . . . . . 11-77|TD2-D. . . . . . . . . . . . . . . 5-12, 8-40|
|POLE98-_ . . . . . . . . . . . . . . . 11-73|RD30-3 . . . . . . . . . . . . . . . 11-71, 72|S-_ . . . . . . . . . . . . . . . . . . . . . 1-34|SH7-_ . . . . . . . . . . . . . . . . . . 11-69|TD2-D-PV . . . . . . . . . . . . . . . . 6-11|
|PON-_. . . . . . . . . . . . . . . . . . . . 5-2|RD400-3 . . . . . . . . . . . . . . 11-71, 72|S500-_-R . . . . . . . . . . . . . . . . . . 3-3|SH-GUIDE_ . . . . . . . 11-73, 75, 77, 81|TD2-IP20 . . . . . . . . . . . . . . . . . 5-12|
|PS_ . . . . . . . . . . . . . . . . . . . . 12-5|RD400-4 . . . . . . . . . . . . . . 11-71, 72|S500-V-_-R. . . . . . . . . . . . . . . . . 3-3|SL-_ . . . . . . . . . . . . . . . . . . . . 1-33|TD3-D. . . . . . . . . . . . . . . 5-12, 8-40|
|PSU1-_ . . . . . . . . . . . . . . . . . . 10-7|RD40-3-508 . . . . . . . . . . . . . . 11-79|S501-_-R . . . . . . . . . . . . . . . . . . 3-4|SOU . . . . . . . . . . . . . . . . . . . . 1-36|TD3-D-PV . . . . . . . . . . . . . . . . 6-11|
|PTFB-2500-JCD . . . . . . . . . . . . . 7-26|RD600-3 . . . . . . . . . . . . . . 11-71, 72|S501-V-_-R. . . . . . . . . . . . . . . . . 3-4|SOW. . . . . . . . . . . . . . . . . . . . 1-36|TD3-IP20 . . . . . . . . . . . . . . . . . 5-12|
|PV-_A-01XL . . . . . . . . . . . . . . . . 6-7|RD600-4 . . . . . . . . . . . . . . 11-71, 72|S505-_-R . . . . . . . . . . . . . . . . . . 3-4|SOX . . . . . . . . . . . . . . . . . . . . 1-36|TI_ . . . . . . . . . . . . . . . . . . . . . 4-21|
|PV-_A-01XL-15 . . . . . . . . . . . . . . 6-7|RD60-3 . . . . . . . . . . . . . . . 11-71, 72|S505H-_-R . . . . . . . . . . . . . . . . . 3-5|SOY . . . . . . . . . . . . . . . . . . . . 1-36|TL-_ . . . . . . . . . . . . . . . . . . . . 1-33|
|PV-_A-01XL-B . . . . . . . . . . . . . . . 6-7|RD63-3-508 . . . . . . . . . . . . . . 11-79|S505H-V-_-R. . . . . . . . . . . . . . . . 3-5|SOY-B . . . . . . . . . . . . . . . . . . . 1-36|TP158HC_ . . . . . . . . . . . . . . . . 14-6|
|PV-_A-01XL-B-15. . . . . . . . . . . . . 6-7|RD800-3 . . . . . . . . . . . . . . 11-71, 72|S505SC-_-R . . . . . . . . . . . . . . . . 3-4|SP . . . . . . . . . . . . . . . .10-11, 13, 15|TP15900-_ . . . . . . . . . . . . . . . . 14-4|
|PV-_A10F85L . . . . . . . . . . . . . . . 6-6|RD800-4 . . . . . . . . . . . . . . 11-71, 72|S505SCH-_-R . . . . . . . . . . . . . . . 3-5|SPP40SP_ . . . . . . . . . . . . . . . . 13-4|TP15914_ . . . . . . . . . . . . . . . . 14-4|
|PV-_A14F. . . . . . . . . . . . . . . . . . 6-4|RD80-3-508 . . . . . . . . . . . . . . 11-79|S506-_-R . . . . . . . . . . . . . . . . . . 3-5|SRU . . . . . . . . . . . . . . . . . . . . 1-36|TPA-_ . . . . . . . . . . . . . . . . . . . 14-5|
|PV-_A-1XL . . . . . . . . . . . . . . . . . 6-7|RDF100J-2 . . . . . . . . . . . . . . . 11-55|S506-V-_-R. . . . . . . . . . . . . . . . . 3-5|SRW . . . . . . . . . . . . . . . . . . . . 1-36|TPA-B-_ . . . . . . . . . . . . . . . . . . 14-5|
|PV-_A-1XL-15 . . . . . . . . . . . . . . . 6-7|RDF100J-3 . . . . . . . . . . . . . . . 11-55|S-8001-_ . . . . . . . . . . . . . . . . . . 8-4|SRX . . . . . . . . . . . . . . . . . . . . 1-36|TPC-_ . . . . . . . . . . . . . . . . . . . 14-2|
|PV-_A-1XL-B. . . . . . . . . . . . . . . . 6-7|RDF100J-4 . . . . . . . . . . . . . . . 11-55|S-8002-_ . . . . . . . . . . . . . . . . . . 8-4|SRY . . . . . . . . . . . . . . . . . . . . 1-36|TPCDS-_ . . . . . . . . . . . . . . . . . 14-2|
|PV-_A-1XL-B-15. . . . . . . . . . . . . . 6-7|RDF200J-2 . . . . . . . . . . . . . . . 11-55|S-8101-_ . . . . . . . . . . . . . . . . . . 8-4|SS . . . . . . . . . . . . . . . . . . . . 10-13|TPCDS-D-_. . . . . . . . . . . . . . . . 14-2|
|PV-_A-2XL . . . . . . . . . . . . . . . . . 6-7|RDF200J-3 . . . . . . . . . . . . . . . 11-55|S-8102-_ . . . . . . . . . . . . . . . . . . 8-4|SSD-_ . . . . . . . . . . . . . . . . . . . . 5-7|TPHCS_-_ . . . . . . . . . . . . . . . . 14-7|
|PV-_A-2XL-15 . . . . . . . . . . . . . . . 6-7|RDF200J-4 . . . . . . . . . . . . . . . 11-55|S-8201-_ . . . . . . . . . . . . . . . . . . 8-4|SSN . . . . . . . . . . . . . . . . . . . . 1-36|TPL-_ . . . . . . . . . . . . . . . . . . . 14-8|
|PV-_A-2XL-B. . . . . . . . . . . . . . . . 6-7|RDF30CC-3 . . . . . . . . . . . . . . 11-55|S-8202-_ . . . . . . . . . . . . . . . . . . 8-4|SSU . . . . . . . . . . . . . . . . . . . . 1-36|TPM-_. . . . . . . . . . . . . . . . . . . 14-3|
|PV-_A-2XL-B-15. . . . . . . . . . . . . . 6-7|RDF30CC-3N . . . . . . . . . . . . . 11-55|S-8203-_ . . . . . . . . . . . . . . . . . . 8-4|SSW . . . . . . . . . . . . . . . . . . . . 1-36|TPMDS-_ . . . . . . . . . . . . . . . . . 14-3|
|PV-_A-3L . . . . . . . . . . . . . . . . . . 6-7|RDF30J-2. . . . . . . . . . . . . . . . 11-55|S-8301-_ . . . . . . . . . . . . . . . . . . 8-4|SSY . . . . . . . . . . . . . . . . . . . . 1-36|TPN-_ . . . . . . . . . . . . . . . . . . . 14-9|
|PV-_A-3L-15 . . . . . . . . . . . . . . . . 6-7|RDF30J-3. . . . . . . . . . . . . . . . 11-55|SA-_ . . . . . . . . . . . . . . . . . . . . 1-35|SSY-RL . . . . . . . . . . . . . . . . . . 1-36|TPS-_ . . . . . . . . . . . . . . . . . . . 14-6|
|PV-_A-3L-B. . . . . . . . . . . . . . . . . 6-7|RDF30J-3-COMP . . . . . . . . . . . 11-55|SAMI-_ . . . . . . . . . . . . . . . . . . 15-2|ST . . . . . . . . . . . . . . . . . . 10-13, 15|TPS-_L . . . . . . . . . . . . . . . . . . 14-6|
|PV-_A-3L-B-15 . . . . . . . . . . . . . . 6-7|RDF30J-3N-COMP . . . . . . . . . . 11-55|SB1XL-S. . . . . . . . . . . . . . . . . . 6-10|STD-_ . . . . . . . . . . . . . . . . . . . . 5-7|TPS-_V . . . . . . . . . . . . . . . . . . 14-6|
|PV-_ANH1 . . . . . . . . . . . . . . . . . 6-5|RDF30J-4. . . . . . . . . . . . . . . . 11-55|SB2XL-S. . . . . . . . . . . . . . . . . . 6-10|STY . . . . . . . . . . . . . . . . . . . . 1-36|TPSFH-_ . . . . . . . . . . . . . . . . . 15-4|
|PV-_ANH1-B. . . . . . . . . . . . . . . . 6-5|RDF400J-2 . . . . . . . . . . . . . . . 11-55|SB3L-S . . . . . . . . . . . . . . . . . . 6-10|T-_ . . . . . . . . . . . . . . . . . . . . . 1-34|TSH_-_B . . . . . . . . . . . . . . 11-75, 88|
|PV-_ANH2 . . . . . . . . . . . . . . . . . 6-5|RDF400J-3 . . . . . . . . . . . . . . . 11-55|SC-_ . . . . . . . . . . . . . . . . . . . . 1-18|T30030-_. . . . . . . . . . . . . . . . . 8-35|TSH_-_T . . . . . . . . . . . . . . 11-75, 88|
|PV-_ANH2-B. . . . . . . . . . . . . . . . 6-5|RDF400J-4 . . . . . . . . . . . . . . . 11-55|SCY . . . . . . . . . . . . . . . . . . . . 1-36|T30060-_. . . . . . . . . . . . . . . . . 8-35|TSH_-_TB. . . . . . . . . 11-67, 69, 73, 75,|
|PV-_ANH3 . . . . . . . . . . . . . . . . . 6-5|RDF600J-2 . . . . . . . . . . . . . . . 11-55|SD_-PB . . . . . . . . . . . . . . . . . . 6-11|T30100-_. . . . . . . . . . . . . . . . . 8-35|. . . . . . . . . . . . . . . 77, 82, 86, 88, 90|
|PV-_ANH3-B. . . . . . . . . . . . . . . . 6-5<br>PV15M-4A-CT. . . . . . . . . . . . . . . 6-6|RDF600J-3 . . . . . . . . . . . . . . . 11-55<br>RDF600J-4 . . . . . . . . . . . . . . . 11-55|SD_-SK . . . . . . . . . . . . . . . . . . 6-11<br>SD00-D . . . . . . . . . . . . . . 5-12, 8-40|T30200-_. . . . . . . . . . . . . . . . . 8-35<br>T30400-_. . . . . . . . . . . . . . . . . 8-35|UHA . . . . . . . . . . . . . . . . . . . . . 2-3<br>UHJ-M . . . . . . . . . . . . . . . . . . . 2-3|
|PV-1A10-1P . . . . . . . . . . . . . . . . 6-3<br>PV-1A10-2P . . . . . . . . . . . . . . . . 6-3<br>PV-1A10F . . . . . . . . . . . . . . . . . 6-3<br>PV-1A10F-CT . . . . . . . . . . . . . . . 6-3|RDF60J-2. . . . . . . . . . . . . . . . 11-55<br>RDF60J-2-COMP . . . . . . . . . . . 11-55<br>RDF60J-3. . . . . . . . . . . . . . . . 11-55<br>RDF60J-3-COMP . . . . . . . . . . . 11-55|SD00-PB . . . . . . . . . . . . . 5-12, 8-40<br>SD00-SK . . . . . . . . . . . . . . . . . 5-12<br>SD12-PB . . . . . . . . . . . . . 5-12, 8-40<br>SD12-SK . . . . . . . . . . . . . 5-12, 8-40|T30600-_. . . . . . . . . . . . . . . . . 8-35<br>T60030-_. . . . . . . . . . . . . . . . . 8-37<br>T60060-_. . . . . . . . . . . . . . . . . 8-37<br>T60100-_. . . . . . . . . . . . . . . . . 8-37|UHJ-T . . . . . . . . . . . . . . . . . . . . 2-3<br>UHJ-W . . . . . . . . . . . . . . . . . . . 2-3<br>W-_ . . . . . . . . . . . . . . . . . . . . 1-33<br>WCF_RN . . . . . . . . . . . . . . . . . 1-11|
|PV-1A10-T . . . . . . . . . . . . . . . . . 6-3<br>PVM-_. . . . . . . . . . . . . . . . . . . . 6-2|RDF60J-4. . . . . . . . . . . . . . . . 11-55<br>RDF60J-4-COMP . . . . . . . . . . . 11-55|SD1-D. . . . . . . . . . . . . . . 5-12, 8-40<br>SD1-D-PV . . . . . . . . . . . . . . . . 6-11|T60200-_. . . . . . . . . . . . . . . . . 8-37<br>T60400-_. . . . . . . . . . . . . . . . . 8-37|W-DUMMY. . . . . . . . . . . . . . . . 1-33<br>X_ . . . . . . . . . . . . . . . . . . 10-16, 17|
|PVS-R-_. . . . . . . . . . . . . . . . . . . 6-2|RDF800L-2. . . . . . . . . . . . . . . 11-55|SD2-D. . . . . . . . . . . . . . . 5-12, 8-40|T60600-_. . . . . . . . . . . . . . . . . 8-37||
|PWR1PLP. . . . . . . . . . . . . . . . . 8-10|RDF800L-3. . . . . . . . . . . . . . . 11-55|SD2-D-PV . . . . . . . . . . . . . . . . 6-11|TB100-_ . . . . . . . . . . . . . . . . 10-10||
|PWR35MM. . . . . . . . . . . . . . . . 8-10|RDF800L-4. . . . . . . . . . . . . . . 11-55|SD3-D. . . . . . . . . . . . . . . 5-12, 8-40|TB200-_ . . . . . . . . . . . . . . . . 10-12||
16-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
## Low-Peak™ Upgrade program and fuse inventory consolidation
The Low-Peak Upgrade program offers superior performance while reducing the number of SKUs that need to be in stock. Bussmann series Low-Peak fuses feature a high degree of current limitation to help provide the superior component protection and help mitigate arc flash hazard.
Listed below are fuse upgrades by branch circuit class.
The left column contains catalog symbols for Bussmann series and competitor products.
The right column contains the Low-Peak upgrade for consolidating and simplifying inventory.
To find out more about the advantages offered by the Low-Peak Upgrade program, visit Eaton.com/bussmannseries.
This is only a consolidated cross reference of the most common fuses. For a more extensive cross reference for fuses, please visit Eaton.com/bussmannseries/FuseFinder.
## 250 Volt Class R/H(K)
## Class CC and Midget Class J
600 Volt Class R/H(K)
~~Fc~~ Fuse symbol Low-Peak u ~~el~~ pgrade ~~Oi~~ Fuse symbol Low-Peak upgrade ~~titstsi‘(‘i‘i‘i‘i‘i‘iézia“™e~~ Fuse symbol ~~(~~ Low-Peak upgrade Fuse symbol Low-Peak upgrade ~~ld~~ A2D LPN-RK_SP A6D LPS-RK_SP A6Y (Type 2B) LP-CC A4J LPJ_SP A2D-R A6K-R ABU AJT A2K A6X (Type 1) AGU CJ A2K-R ATS-DE ATDR CJS ~~=~~ A2Y (Type 1) ~~=,~~ CHR ATM GF8B AT-DE CTS-R ATMR HRCXXJ ~~— —#~~ CHG DES ATQ J CRN-R (Type 3) DES-R BAF JA CTN-R DLS BAN JCL ~~———~~ DEN DLS-R[†] BLF ~~re~~ JDL DLN ECS-R BLN JFL DLN-R[†] ERS CCMR JHC ECN FLS CM JKS ECN-R FLS-R CMF JLS ERN FRS CNM JTD LPJ_SP FLN FRS-R CNQ FLN-R FTS-R CTK ~~—f~~ FRN GDS CTK-R Class L FRN-R HA FLM FTN-R KLS-R FLQ Fuse symbol Low-Peak upgrade ~~_— —~~ 8 ~~— yg~~ A4BQ KRP-C_SP GDN ~~_~~ KOS ~~——_~~ FNM = ~~a~~ A4BT HAC-R KTS-R FNQ A4BY HB LES GGU ~~=~~ KLN-R LES-R HCLR A4BY CLF (Type 55) KON LES-RK KLK CLL KTN-R LKS KLK-R CLU LENRK LLS-RK KTK HRC-L LKN LOS-RK KTK-R KLLU LLN-RK NLS MCL KLPC LON-RK NOS MEN KLU NCLR NRS MEQ KTU NLN OTS MOF L NON RES[††] MOL T LCL NRN RFS OTM OTN RHS TRM LCU KRP-C_SP REN[††] RLS 6JX LP-CC RFN SCLR *FNQ-R suggested on primary of RHN TRS control transformers. ~~=l=/~~ RLN TRS-R ~~=~~ ATQR ~~=~~ TR 656 FNQ-R FNQ-R 655 10KOTS KLDR 660 50KOTS LPS-RK_SP 10KOTN † Obsolete, must be replaced with a 50KOTN LPN-RK_SP another electrically equivalent fuse. † Obsolete, must be replaced with a †† 70 to 600 amp versions obsoleted. another electrically equivalent fuse. Must be replaced with a another †† 70 to 600 amp versions obsoleted. electrically equivalent fuse.
- †† 70 to 600 amp versions obsoleted. Must be replaced with a another electrically equivalent fuse.
The competitive fuse catalog symbols shown were derived from published information for various manufacturers. Because competitive products may differ from Bussmann series products, it is recommended that each selected product be checked for required electrical and mechanical characteristics before substitutions are made. Eaton is not responsible for misapplications of our products.
Overcurrent protection is application dependent. Consult the latest catalogs and application literature, or contact our Application Engineers toll free, 7:00 a.m. to 5:00 p.m. Central time, Monday-Friday at 855-287-7626 (855-BUSSMANN).
## Customer satisfaction team
Available to answer questions regarding Bussmann series products and services. Available Monday-Friday, 7:00 a.m. — 6:00 p.m. Central time.
- Toll-free phone: 855-287-7626 (855-BUSSMANN)
Emergency and after-hours orders
Next flight out or will call shipment for time-critical needs. Customers pay only standard product price, rush freight charges, and modest emergency service fee. Place these orders through the customer satisfaction team during regular business hours.
My.Eaton.com
Provides real time product availability, net pricing, order status and shipment tracking. Log onto My.Eaton.com or call:
- 1-800-468-1705 Option #3 for log-in assistance.
## Application engineering
Technical application assistance is available to all customers. Available Monday-Friday, 7:00 a.m. — 5:00 p.m. Central time.
- Toll-free phone: 855-287-7626 (855-BUSSMANN)
- Email: FuseTech@Eaton.com
- Toll-free fax: 800-544-2570
- Email: BussCustSat@Eaton.com
- After hours: 314-995-1342
## VA ea r " at f **Bussmann series toolbox**
All the tools you need, in the palm of your hand.
> FC[2] Available Fault Current Calculator te 7 oe > Low Voltage Fuse Selector > Medium Voltage Fuse Selector me: Pears a el a rie, ea Bay > Surge Protective Device Selector a - > Connector Selector F 7 > er Arcing Current Calculator . ra+
> SCCR Protection Suite > OSCAR™ 2.1 Online Compliance > ie Selective Coordination Designer
- RoHS Compliance Product Search
> Distributor Locator i
**http://toolbox.bussmann.com**
Eaton 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com
Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton.com/bussmannseries
© 2018 Eaton All Rights Reserved Printed in USA Publication No. 1007 October 2018
Eaton and Bussmann are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton.
For Eaton’s Bussmann series product information, call 1-855-287-7626 or visit: Eaton.com/bussmannseries
Follow us on social media to get the latest product and support information.
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →