Image not available
Illustrative purposes only
1502460000
PLUGGABLE
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: WEIDMULLER / PARTNER STOCK
- Product type: Pluggable Terminal Blocks
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 60 |
| Price | 4.42 € |
| Current stock | 50+ |
| Lead time | 30 days |
**Data sheet** ~~Ll~~ ## **OMNIMATE Signal - series BL/SL 5.08 BLT 5.08HC/08/180B SN OR BX** **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com ## **Product image** Female plugs with TOP screw connection system for connecting wires with straight 180° outlet direction. The female connectors provide space for labelling and can be coded. HC = High Current. ## **General ordering data** |Type|BLT 5.08HC/08/180B SN OR BX| |---|---| |Order No.|1502460000| |Version|PCB plug-in connector, female plug, 5.08 mm,| ||Number of poles: 8, 180°, TOP connection,| ||Clampingrange, max. : 2.5 mm², Box| |GTIN(EAN)|4008190147334| |Qty.|42pc(s).| |Product data|IEC: 400 V / 27 A / 0.2 - 2.5 mm²| ||UL: 300 V/17 A/AWG 26 - AWG 14| |Packaging|Box| Creation date September 7, 2020 11:26:09 AM CEST Catalogue status 05.09.2020 / We reserve the right to make technical changes. 1 **Data sheet** — **OMNIMATE Signal - series BL/SL 5.08 BLT 5.08HC/08/180B SN OR BX** ## **Technical data** ~~Ld~~ **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com ## **Dimensions and weights** |Width|42.66 mm|Width(inches)|1.68 inch| |---|---|---|---| |Height|12.2 mm|Height(inches)|0.48 inch| |Depth|31.8 mm|Depth(inches)|1.252 inch| |Net weight|24.667 g||| |**System Parameters**|||| |Product family|OMNIMATE Signal - series|Type of connection|| ||BL/SL 5.08||Field connection| |Wire connection method|TOP connection|Pitch in mm(P)|5.08 mm| |Pitch in inches(P)|0.2 inch|Conductor outlet direction|180°| |Number ofpoles|8|L1 in mm|35.56 mm| |L1 in inches|1.4 inch|Number of rows|1| |Pin seriesquantity|1|Rated cross-section|2.5 mm²| |Touch-safe protection acc. to DIN VDE||Volume resistance|| |57 106|Safe from finger touch||≤ 5mΩ| |Can be coded|Yes|Strippinglength|13 mm| |Tighteningtorque,min.|0.4 Nm|Tighteningtorque,max.|0.5 Nm| |Clampingscrew|M 2.5|Screwdriver blade|0.6 x 3.5| |Screwdriver blade standard|DIN 5264|Pluggingcycles|25| |Plugging force/pole, max.|8 N|Pulling force/pole, max.|7 N| |**Material data**|||| |Insulatingmaterial|PBT|Colour|orange| |Colour chart(similar)|RAL 2000|Insulatingmaterialgroup|IIIa| |Comparative Tracking Index (CTI)|≥ 200|Insulation strength|≥ 108Ω| |UL 94 flammabilityrating|V-0|GWFI|960 °C| |Contact material|CuSn|Contact surface|tinned| |Layer structure ofplugcontact|4...8µm Sn hot-diptinned|Storage temperature,min.|-40 °C| |Storage temperature,max.|70 °C|Operatingtemperature,min.|-50 °C| |Operatingtemperature,max.|100 °C|Temperature range,installation,min.|-25 °C| |Temperature range, installation, max.|100 °C||| ## **Conductors suitable for connection** |Clampingrange,min.|0.13 mm²| |---|---| |Clampingrange,max.|2.5 mm²| |Wire connection cross section AWG,|AWG 28| |min.|| |Wire connection cross section AWG,|AWG 14| |max.|| |Solid,min. H05(07)V-U|0.2 mm²| |Solid,max. H05(07)V-U|2.5 mm²| |Flexible,min. H05(07)V-K|0.2 mm²| |Flexible,max. H05(07)V-K|1.5 mm²| |w. plastic collar ferrule, DIN 46228 pt 4,|0.2 mm²| |min.|| |w. plastic collar ferrule, DIN 46228 pt 4,|1.5 mm²| |max.|| |w. wire end ferrule, DIN 46228 pt 1,|0.2 mm²| |min.|| |w. wire end ferrule, DIN 46228 pt 1,|1.5 mm²| |max.|| |Plug gauge in accordance with EN|2.4 mm x 1.5 mm ; 2.4 mm| |60999 a x b; ø|| Creation date September 7, 2020 11:26:09 AM CEST Catalogue status 05.09.2020 / We reserve the right to make technical changes. 2 **Data sheet** ## **OMNIMATE Signal - series BL/SL 5.08 BLT 5.08HC/08/180B SN OR BX** ## **Technical data** ~~ass~~ **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com ~~so~~ |Clampable conductor|Cross-section for conductor connection<br>Type|Cross-section for conductor connection<br>Type||fine-wired|| |---|---|---|---|---|---| |||nominal||0.5 mm²|| ||wire end ferrule<br>Strippinglength<br>Recommended wire-<br>end ferrule<br>~~eee~~|||nominal<br>14 mm<br>H0,5/18 OR|| ||Cross-section for conductor connection<br>Type<br>fine-wired<br>nominal<br>1 mm²<br>wire end ferrule<br>Strippinglength<br>nominal<br>15 mm<br>Recommended wire-<br>end ferrule<br>H1,0/18 GE<br>Cross-section for conductor connection<br>Type<br>fine-wired<br>nominal<br>1.5 mm²<br>~~a~~<br>~~ee eee~~<br>~~a~~||||| ||wire end ferrule|Strippinglength||nominal|15 mm| |||Recommended wire-||H1,5/18D SW|H1,5/18D SW| |||end ferrule|||| |||Strippinglength||nominal|12 mm| |||Recommended wire-||H1,5/12|| |||end ferrule|||| |Reference text|The outside diameter of the plastic collar should not be larger than the pitch (P), Length of ferrules||||| ||is to be chosen dependingon theproduct and the rated voltage.||||| |Max. clamping range|2.5 mm²||||| |**Rated data acc. to IEC**|||||| |tested acc. to standard||Rated current, min. number of poles|||| ||IEC 60664-1,IEC 61984|(Tu=20°C)|27 A||| |Rated current, max. number of poles||Rated current, min. number of poles|||| |(Tu=20°C)|19 A|(Tu=40°C)|24 A||| |Rated current, max. number of poles||Rated voltage for surge voltage class /|||| |(Tu=40°C)|16 A|pollution degree II/2|400 V||| |Rated voltage for surge voltage class /||Rated voltage for surge voltage class /|||| |pollution degree III/2|320 V|pollution degree III/3|250 V||| |Rated impulse voltage for surge voltage||Rated impulse voltage for surge voltage|||| |class/ pollution degree II/2|4 kV|class/ pollution degree III/2|4 kV||| |Rated impulse voltage for surge voltage||Short-time withstand current resistance|||| |class/ contamination degree III/3|4 kV||3 x 1s with 100 A||| |**Rated data acc. to CSA**|||||| |Institute (CSA)|Co|Certificate No. (CSA)|200039-1121690||| |Rated voltage(UsegroupB/CSA)|300 V|Rated voltage(UsegroupD/CSA)|300 V||| |Rated current(UsegroupB/CSA)|15 A|Rated current(UsegroupD/CSA)|15 A||| |Wire cross-section,AWG,min.|AWG 26|Wire cross-section,AWG,max.|AWG 14||| |Reference to approval values|Specifications are||||| ||maximum values, details -||||| ||see approval certificate.||||| Creation date September 7, 2020 11:26:09 AM CEST Catalogue status 05.09.2020 / We reserve the right to make technical changes. 3 **Data sheet** — **OMNIMATE Signal - series BL/SL 5.08 BLT 5.08HC/08/180B SN OR BX** ## **Technical data** ~~Ld~~ **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com ## **Rated data acc. to UL 1059** |**Type tests**||| |---|---|---| |Test: Durability of markings|Standard<br>DIN EN 61984 section 7.3.2 / 09.02 taking<br>pattern from DIN EN 60068-2-70/07.96|| ||Test<br>mark of origin,type of material,date clock|| ||Evaluation<br>available|| ||Test<br>durability|| ||Evaluation<br>passed|| |Test: Misengagement (Non-<br>interchangeability)|Standard<br>DIN EN 61984 section 6.3 and 6.9.1 / 09.02,<br>DIN EN 60512-13-5/11.06|| ||Test<br>180° turned with codingelements|| ||Evaluation<br>passed|| ||Test<br>visual examination|| ||Evaluation<br>passed|| |Test: Clampable cross section|Standard<br>DIN EN 60999-1 section 7 and 9.1 / 12.00, DIN<br>EN 60947-1 section 8.2.4.5.1/12.02|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>solid 0.08 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>stranded 0.08 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>solid 2.5 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>stranded 2.5 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 26/1| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 26/19| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 14/1| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 14/19| ||Evaluation<br>passed|| Creation date September 7, 2020 11:26:09 AM CEST Catalogue status 05.09.2020 / We reserve the right to make technical changes. 4 **Data sheet** — **OMNIMATE Signal - series BL/SL 5.08 BLT 5.08HC/08/180B SN OR BX** ## **Technical data** ~~Ld~~ Test for damage to and accidental loosening of conductors ||Weidmiiller=|Weidmiiller=| |---|---|---| |**OMNIMATE Signal - series BL/SL 5.08**<br>**BLT 5.08HC/08/180B SN OR BX**|**Weidmüller Interface GmbH & Co. KG**<br>Klingenbergstraße 26<br>D-32758 Detmold|| ||Germany|| ||Fon: +49 5231 14-0|Fon: +49 5231 14-0| ||Fax: +49 5231 14-292083<br>www.weidmueller.com<br>~~a~~|| |Standard|DIN EN 60999-1 section 9.4/12.00|| |Requirement|0.2 kg|| |Conductor type|Type of conductor|AWG 28/1| ||and conductor cross-|| ||section|| ||Type of conductor|AWG 26/19| ||and conductor cross-|| ||section|| |Evaluation|passed|| |Requirement|0.3 kg|| |Conductor type|Type of conductor|solid 0.5 mm²| ||and conductor cross-|| ||section|| ||Type of conductor|stranded 0.5 mm²| ||and conductor cross-|| ||section|| |Evaluation|passed|| |Requirement|0.7 kg|| |Conductor type|Type of conductor|solid 2.5 mm²| ||and conductor cross-|| ||section|| ||Type of conductor|stranded 2.5 mm²| ||and conductor cross-|| ||section|| ||Type of conductor|AWG 14/1| ||and conductor cross-|| ||section|| ||Type of conductor|AWG 14/19| ||and conductor cross-|| ||section|| |Evaluation|passed|| Creation date September 7, 2020 11:26:09 AM CEST Catalogue status 05.09.2020 / We reserve the right to make technical changes. 5 **Data sheet** — **OMNIMATE Signal - series BL/SL 5.08 BLT 5.08HC/08/180B SN OR BX** |Pull-out test|Standard<br>DIN EN 60999-1 section 9.5/12.00|Standard<br>DIN EN 60999-1 section 9.5/12.00| |---|---|---| ||Requirement<br>≥5 N|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>AWG 28/1| ||Evaluation<br>passed|| ||Requirement<br>≥10 N|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>AWG 26/19| ||Evaluation<br>passed|| ||Requirement<br>≥20 N|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>solid 0.5 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>stranded 0.5 mm²| ||Evaluation<br>passed|| ||Requirement<br>≥40 N|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>AWG 14/1| |||Type of conductor<br>and conductor cross-<br>section<br>AWG 14/19| ||Evaluation<br>passed|| ||Requirement<br>≥50 N|| ||Conductor type|Type of conductor<br>and conductor cross-<br>section<br>solid 2.5 mm²| |||Type of conductor<br>and conductor cross-<br>section<br>stranded 2.5 mm²| ||Evaluation<br>passed|| ## **Technical data** ~~Ld~~ Creation date September 7, 2020 11:26:09 AM CEST Catalogue status 05.09.2020 / We reserve the right to make technical changes. 6 **Data sheet** ## **OMNIMATE Signal - series BL/SL 5.08 BLT 5.08HC/08/180B SN OR BX** ## **Technical data** ~~ass~~ **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com ~~So~~ ## **Notes** |Notes|• Additional colours on request| |---|---| ||• Gold-plated contact surfaces on request| ||• Rated current related to rated cross-section & min. No. of poles.| ||• Wire end ferrule without plastic collar to DIN 46228/1| ||• Wire end ferrule with plastic collar to DIN 46228/4| ||• Crimp form A for wire end ferrules with PZ 6/5 crimping tool are recommended for the largest cable sizes.| ||• P on drawing = pitch| ||• Rated data refer only to the component itself. Clearance and creepage distances to other components are to| ||be designed in accordance with the relevant application standards.| ||• Longterm storage of theproduct with average temperature of 50 °C and average humidity70%, 36 months| |IPC conformity|Conformity: The products are developed, manufactured and delivered according international recognized| ||standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties| ||in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request.| |**Approvals**|| |Approvals|@SALuslill| |**Approvals**|| |---|---| |Approvals|@SALuslill| |ROHS|Conform| |**Downloads**|| |Approval/Certificate/Document of|CB Certificate| |Conformity|CB Testreport| |Brochure/Catalogue|FL DRIVES EN| ||FL DRIVES DE| |Engineering Data|STEP| Creation date September 7, 2020 11:26:09 AM CEST Catalogue status 05.09.2020 / We reserve the right to make technical changes. 7 **Data sheet** ## **OMNIMATE Signal - series BL/SL 5.08 BLT 5.08HC/08/180B SN OR BX** ## **Drawings** ## **Graph** ## **Product benefits** **Weidmüller Interface GmbH & Co. KG** Klingenbergstraße 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com **==> picture [129 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Lower assembly costs<br>Secure in a matter of seconds<br>**----- End of picture text -----**<br> ## **Product benefits** **==> picture [158 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Guaranteed secure fixing<br>For wall thickness from 0.5 to 2 mm<br>**----- End of picture text -----**<br> Creation date September 7, 2020 11:26:09 AM CEST Catalogue status 05.09.2020 / We reserve the right to make technical changes. 8
Updated at April 29, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →