11-BG00-31-A12060
SAFETY RELAYS
- Manufacturer: BANNER ENGINEERING
- Product type: Safety Relays
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 76.57 € |
| Current stock | 10+ |
| Lead time | 30 days |
Mechanically Linked Contactors ## Features Provide additional 10 amp or 18 amp carrying capability to any safety system - For use with a safety device (for example, a safety light screen or safety module/controller) which has solid state or hard contact outputs - Provides three normally open safety contacts and one normally closed monitoring contact for any safety system - Auxiliary contact blocks, either three or four normally open depending on the model, are available - • 24 V DC or 120 V AC coil voltage, depending on model • 10 amp or 18 amp contact rating • Generally used in pairs for safety function; normally closed contacts used for the monitoring function of a safety system (for example, External Device Monitoring EDM) - • Standard DIN rail or flush-mounting • BF series has built-in surge suppressor on coil ## Models **==> picture [504 x 56] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||| |---|---|---|---|---|---| |Model|Coil Voltage|[(1)]|Safety Contacts|Monitoring Contacts|Contact Rating| |11-BG00-31-A12060|120 V AC| |10 amps (thermal)| |11-BG00-31-D024|24 V DC| |Three normally open|One normally closed| |BF1801A-12060|120 V AC| |18 amps|[(2)]|(inductive)| |BF1801L-024|24 V DC| **----- End of picture text -----**<br> ## Overview Contactors can take many forms, thought the most common in a safety circuit are forced-guided, mechanically linked relays. The mechanical linkage between the contacts allows the device to be monitored by an external monitoring circuit for certain failures. Depending on the application, the use of contactors can facilitate controlling voltage and current that differs from the output signal switching device (OSSD) outputs of the safety devices. Contacts can also be used to control an additional number of hazards by creating multiple safety stop circuits. WARNING: • Not a stand-alone point-of-operation guarding device • This Banner Engineering Corp. device is not a stand-alone point-of-operation guarding device, as defined by OSHA regulations. Failure to install point-of-operation guards on hazardous machinery can result in a dangerous condition that could lead to serious injury or death. • Install point-of-operation guarding devices, such as safety light curtains and/or hard guards, to protect personnel from hazardous machinery. ## Important... Read this before proceeding! The user is responsible for satisfying all local, state, and national laws, rules, codes, and regulations relating to the use of this product and its application. Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and maintenance instructions. Please contact a Banner Applications Engineer with any questions regarding this product. The user is responsible for making sure that all machine operators, maintenance personnel, electricians, and supervisors are thoroughly familiar with and understand all instructions regarding the installation, maintenance, and use of this product, and with the machinery it controls. The user and any personnel involved with the installation and use of this product must be thoroughly familiar with all applicable standards, some of which are listed within the specifications. Banner Engineering Corp. makes no claim regarding a specific recommendation of any organization, the accuracy or effectiveness of any information provided, or the appropriateness of the provided information for a specific application. - WARNING: • Not a safeguarding device • Failure to follow these instructions could result in serious injury or death. • This device is not considered a safeguarding device because it requires an overt action by an individual to stop machine motion or hazards. A safeguarding device limits or eliminates an individual's exposure to a hazard without action by the individual or others. This device cannot be substituted for required safeguarding. Refer to the applicable standards to determine those requirements. ## Applicable US Standards ANSI B11 Standards for Machine Tools Safety NFPA 79 Electrical Standard for Industrial Machinery ANSI/RIA R15.06 Safety Requirements for Industrial Robots and Robot Systems ## Applicable International Standards ISO 12100 Safety of Machinery – General Principles for Design – Risk Assessment and Risk Reduction EN 60204-1 Electrical Equipment of Machines Part 1: General Requirements (1) One Arc Suppressor is needed for each BG Series relay across the coil (see "Suppressors for Mechanically Linked Contactors" on page 4). > (2) NC contact is rated at 10 amps. Original Instructions 17-Apr-25 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com p/n: 111881 Rev. C Mechanically Linked Contactors ISO 13849-1 Safety of Machinery – Safety-Related Parts of Control Systems – Part 1: General Principles for Design ISO 13856-1 (EN1760-1), Safety of Machinery – Pressure-Sensitive Protective Devices ## Specifications Supply Voltage and Current 11-BG00-31-D024 and BF1801L-024 : 24 V DC 11-BG00-31-A12060 and BF1801A-12060 : 120 V AC Operational Voltage Limits: Pick-up: (0.8-1.1) x Us Drop-out: (0.1-0.4) x Us ## Frequency Limit Application Notes 25 Hz to 40 Hz (derating for use at 61 Hz to 400 Hz) Terminal Tightening Torque Min./Max. 0.8 Nm to 1 Nm (0.59 lb/ft to 0.74 lb/ft) for coil terminals 1.5 Nm to 1.8 Nm (1.1 lb/ft to 1.3 lb/ft) for contact terminals There are no adjustments and no user-serviceable parts Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Max. Wire Gauge (for One or Two Wires) 18 AWG to 12 AWG Flexible without Ferrule: 0.75 mm² to 2.5 mm² Flexible with Ferrule: 2 x 1 mm² or 1 x 2.5 mm² Average Coil Consumption at 20 °C **==> picture [150 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> 11-BG00-31-D024 BF1801L-024<br>In-Rush<br>3.2 W 2.4 W<br>60 Hz Holding<br>Output Configuration<br>Number of NO Contacts: 3<br>Number of NC Contacts: 1<br>**----- End of picture text -----**<br> Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced.For additional product support, go to www.bannerengineering.com. For additional product support, go to www.bannerengineering.com. Output Response Time (ms) **==> picture [539 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> Output Configuration BG00-31-11- BF1801L-024 BG00-31-11- BF1801A-12060 Current Limiting, Class 2 Power Supply.<br>Number of NO Contacts: 3 D024 A12060 Supply wiring leads < 24 AWG shall not be spliced.For additional product support, go to www.bannerengineering.com.<br>Number of NC Contacts: 1 Closing NO 18-25 42-58 12-21 8-24<br>Output Ratings Opening NO 2-3 7-13 9-18 10-20 Supply Required Overcurrent Supply Required Overcurrent<br>Max. Voltage: 690 V Wiring Protection (A) Wiring Protection (A)<br>Max. Current: Closing NC 3-5 11-17 17-26 17-30 (AWG) (AWG)<br>11-BG Series:BF Series: 18 A (≤ 440 V; 55 °C) 10 A (resistive) Opening NC 11-17 32-42 7-17 7-18 20 5.0 26 1.0<br>Mechanical Life Environmental Rating 22 3.0 28 0.8<br>20,000,000 operations NEMA 1, IP20 24 1.0 30 0.5<br>Conventional Free Air Thermal Current Ith (≤ 40° C) Contactors must be installed inside an enclosure rated NEMA 3<br>11-BG Series: 10 A (IP54) or better Certifications<br>BF Series: 25 A Mounting Banner Engineering BV<br>Rated Insulation Voltage (Ui) Mounts to standard 35 mm DIN-rail track or flush mount (4 screws) Park Lane, Culliganlaan 2F bus 3<br>690 V Operating Conditions 1831 Diegem, BELGIUM<br>B10d according to ISO 13849-1 Operating Temperature: –40 °C to +60 °C (–40 °F to +140 °F)<br>Rated Load 1,600,000 cycles Storage Temperature: –55 °C to +70 °C (–67 °F to +158 °F)<br>Maximum relative humidity: 90% at +50 °C maximum relative e(Q)us<br>humidity (non-condensing) LISTED 48D6 IND. COMT. EQ.<br>**----- End of picture text -----**<br> ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change. **==> picture [517 x 136] intentionally omitted <==** **----- Start of picture text -----**<br> BF Series<br>11-BG Series<br>7 45.0 [1.77"] 7<br>57.0 [2.24"] 44.0 [1.73"] 35.0 [1.38"]<br>98.5 [3.88"] DC Coil<br>34.9 [1.37"]<br>r _-!| +t_£ | 80.7 [3.18"] AC Coil<br>' [59] [eoeoe CyL _| ; orsrante!<br>58.0 [2.28"] 50.0 [1.97"] lo Oa O _-—— b— Oo OOO ©<br>81.0 [3.19"] 71.0 [2.79"]<br>| OOOOSO a | am)<br>(] L<br>4.5 [0.18"] 5.5 [0.21"]<br>—_— | | HI a (oge) Be |<br>**----- End of picture text -----**<br> ## Mechanical Installation Flush-mount (clearance for user-supplied M3 hardware) or mount to 35 mm DIN rail. The contactor must be mounted inside an enclosure rated NEMA 3, IEC IP54, or better. ## Electrical Installation As the contactors can interface to a multitude of machine control configurations, it is not possible to give exact wiring instructions for the output contacts. The following guidelines are general in nature. Installation and wiring must be made by qualified personnel and must comply with the NEC (National Electrical Code), NFPA79 or IEC 60204-1, and all applicable local standards and codes. page 2 17-Apr-25 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com Mechanically Linked Contactors - WARNING: • Risk of electric shock • Use extreme caution to avoid electrical shock. Serious injury or death could result. • Always disconnect power from the safety system (for example, device, module, interfacing, etc.), guarded machine, and/or the machine being controlled before making any connections or replacing any component. Lockout/tagout procedures might be required. Refer to OSHA 29CFR1910.147, ANSI Z244-1, or the applicable standard for controlling hazardous energy. - • Make no more connections to the device or system than are described in this manual. Electrical installation and wiring must be made by a Qualified Person[(3)] and must comply with the applicable electrical standards and wiring codes, such as the NEC (National Electrical Code), NFPA 79, or IEC 60204-1, and all applicable local standards and codes. Since the contactors can switch high levels of energy, the user must consider and prevent the possibility of arc flash hazards. Arc flash can release dangerous amounts of heat and blast energy. When using low-voltage equipment (240 V or less) being fed by small transformers (125 kVA or less) the potential hazard is small, but the risk increases with higher voltage or larger transformers. The contactors may be required to be located in such a manner that minimizes arc flash hazards. Refer to NFPA70E for more information. NOTE: Placing a surge suppressor on the coil of a contactor reduces the make and break surge current, which reduces the arc of the contact controlling the coil. To satisfy the requirements of Category 3 or 4 of ISO 13849-1 and Control Reliability (OSHA/ANSI), one normally closed mechanically linked (forced guided) contact from each contactor must be monitored by the External Device Monitoring (EDM) function of the safety device. When redundant contactors are used, this will enable the detection of a failure, such as a welded contact, and prevent successive machine cycles. It is the user’s responsibility to monitor the contactors’ normally closed contacts, to ensure that any single failure will not result in a hazardous condition and will prevent a successive machine cycle. **==> picture [141 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> 11-BG Series<br>A1 13 21 33 43<br>A2 14 22 34 44<br>**----- End of picture text -----**<br> **==> picture [132 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> BF Series<br>L1 L2 L3<br>A1 1 3 5 21<br>A2 2 4 6 22<br>T1 T2 T3<br>**----- End of picture text -----**<br> ## Terminal Wiring Diagrams **==> picture [338 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> 11-BG Series BF Series<br>13 21 33 43 A1 A2<br>NO NC NO NO At+<br>1NO 3NO 5NO 21NC<br>L1 L2 L3<br>88008 BG0031x Lk<br>[co ae BF1801x<br>Oo oO 0<br>@8ee8|<br>NO NCNONO ini<br>2NO 4NO 6NO 22NC<br>T1 T2 T3<br>A1 A2<br>**----- End of picture text -----**<br> (3) A person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work. 17-Apr-25 page 3 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com Mechanically Linked Contactors ## Accessories Auxiliary Contacts for Mechanically Linked Contactors ## 11-BGX10-40 - Non-Safety Auxiliary Contacts: Adds normally open contacts to the primary contactor(s). - • Contacts: 4 N.O. • Positively Guided: No (Aux. only) • Used with: 11-BG Series 11-G484-30 - Safety/Auxiliary Contacts: Adds normally open contacts to the primary contactor(s). - • Contacts: 3 N.O. • Positively Guided: Yes • Used with: BF Series ## Suppressors for Mechanically Linked Contactors ## 11-BGX77-048 - Suppressor for Mechanically Linked Contactors: Extends the life of the actuating device—such as a light screen or control module—that uses a mechanically linked contactor. (Two are required for each pair of relays.) - Voltage: 48 V DC (maximum) - • Used with: 11-BG00-31-D024 ## Contact Us Banner Engineering Corp. headquarters is located at: 9714 Tenth Avenue North | Plymouth, MN 55441, USA | Phone: + 1 888 373 6767 For worldwide locations and local representatives, visit www.bannerengineering.com. ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. 17-Apr-25 page 4 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →