Image not available
Illustrative purposes only
88827155
Analogue Timer, MLR1, Recycling, 0.1 s, 100 h, 7 Ranges, 1 Changeover Relay
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CROUZET
- Product type: Analogue Timers - DIN Rail
- Product Range:MLR1 Series; Timer Functions:Recycling; Time Min:0.1s; Time Max:100h; No. of Timing Ranges:7Ranges; Timer Output:1 Changeover Relay; Supply Voltage Max:240VAC; Current
- SVHC: Lead (21-Jan-2025)
- Time Max: 100h
- Time Min: 0.1s
- Timer Output: 1 Changeover Relay
- Product Range: MLR1
- Timer Functions: Recycling
- Current Rating Nom: 8A
- Supply Voltage Max: 240VAC
- No. of Timing Ranges: 7Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 72.5 € |
| Current stock | 50+ |
| Lead time | 30 days |
## Repeat Cycle Analog Timer ## **DIN-Rail Mount 17.5 mm** ## Chronos2 MLR1 Series _The Chronos 2 range of industrial timers: ideal for timing, monitoring and counting functions. Available in single or multi-function versions, to meet the specific needs of each application._ Electrical Control & Protection > Timer Relays > DIN-Rail > Analog **> Relay Output** ## **Highlights** - Mono-function - Multi-range - Multi-voltage - Screw terminals - Possibility of external load connection in parallel to the control input - 3-wire PNP sensor compatible - Nominal rating 8 A ## **Standards** - LED status indicator ## **Part Numbers** **==> picture [47 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 88827155<br>**----- End of picture text -----**<br> Functions: L - Li Series: MLR1 ## **Part numbering system** **==> picture [381 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> Product line: Output Type: Power Supply:<br>88: Control 0: Static 3: 12-240 VAC/DC<br>1: Relay 4: 24-240 VAC or 24-240 VAC/DC<br>5: 24 VDC / 24-240 VAC or 24-240 VAC/DC<br>6: 230-240 / 380-440 VAC<br>88 827 1 0 3<br>Function:<br>0: Multifunction U 5: Function L/Li<br>Casing:<br>1: Function A 6: Function K<br>827: 17.5 mm<br>865/866: 22.5 mm 2: Function B 7: Function Q<br>3: Function C 8: Multifunction X<br>4: Function H/Ht<br>**----- End of picture text -----**<br> ## **More info.** **==> picture [23 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> HERE<br>**----- End of picture text -----**<br> 1 Repeat Cycle Analog Timer ## **Specifications** |**Specifications**|||||| |---|---|---|---|---|---| |**Specifications**|||**88827155**||| ||||||| |**Inputs**<br>~~eee~~|||||| |Supply voltage|||24-240 VAC/DC||| ||||||| |Voltage supply tolerance|||-15%, +10%||| |Operating factor|||100%||| |Max power consumption at Un|||0.6 W (24 VDC)<br>1.1 VA (24 VAC)<br>10 VA (120 VAC)<br>28 VA (240 VAC)||| |Immunity to power micro cuts|||< 10 ms||| ||||||| |**Timing**<br>Timing ranges<br>EE|||1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h<br>ee||| ||||||| |Minimum control pulse duration|||30 ms DC / 50 ms AC||| ||||||| |Recovery time (after by de-energization)|||120 ms||| |Setting accuracy (full range)|||IEC/EN 61812-1: ± 0.5% with constant parameters||| |Drift temperature|||± 0.05% /°C||| ||||||| |Drift voltage|||± 0.2% / V||| ||||||| |**Outputs**<br>Outputs configuration<br>ME|||1 changeover relay||ee| |Maximum switching voltage|||8 A 250 VAC resistive<br>8 A 30 VDC resistive||| ||||||| |Maximum switching power (resistive)|||250 VAC / 8 A resistive<br>125 VDC / 0.3 A resistive||| ||||||| |Electrical life (operations)|||10⁵<br>8 A 250 VAC resistive||| ||||||| |Minimum breaking current|||10 mA / 5 VDC||| |Mechanical life (operations)|||10x106 cycles||| |Rated power|||2000 VA / 40 W||| ||||||| |Dielectric strength|||IEC/EN 60664-1: 2.5 kV / 1 min / 1 mA / 50 Hz||| ||||||| |**Insulation**<br>eee|||||| |Insulation coordination|||IEC/EN 60664-1: Voltage surge category III||| ||||||| |Rated impulse voltage|||IEC/EN 60664-1, IEC/EN 61812-1, IEC 62314:2022: 5 kV (1.2/50 μs)||| |Clearance / creepage distances|||IEC/EN 60664-1: 4 kV / 3 mm<br>Pollution degree 2||| |Insulation resistance|||IEC/EN 60664-1: 100 MΩ (500 VDC)||| 2 ©Crouzet - Technical Datasheet - 10/01/2025 - www.crouzet.com Repeat Cycle Analog Timer ## **Specifications** |**Specifications**||| |---|---|---| |**Specifications**||**88827155**| |||| |**General characteristics**||| |||| |Display||No, but status indicator.<br>Un : while counting, green LED blinks when relay is closed and flashes when relay is open.| |Display accuracy||IEC/EN 61812-1: ± 10% / 25°C| |Casing||17.5 mm| |Mounting||IEC/EN 60715: 35 mm symmetrical DIN-Rail| |Mounting position||Vertical| |Housing material||Self-extinguishing<br>Incandescent wire test| |||| |Degree of protection||According to IEC/EN 60529 :<br>Terminal block : IP20<br>Housing : IP40<br>Front face : IP50| |||| |Terminal capacity||Single-wire without ferrule:<br>1x0,5 - 3,3 mm² (AWG 20 - AWG 12)<br>2x0,5 - 2,5 mm² (AWG 20 - AWG 14)<br>Multi-wire with ferrule:<br>1x0.5 - 2.5mm² (AWG20 - AWG14)<br>2x0.5 - 1.5mm² (AWG20 - AWG16)| |Maximum tightening torques||IEC 60947-1 : 0.5 - 0.6 N.m| |Operating temperature||-20°C to +60°C| |Storage temperature||-30°C to +60°C| |Humidity||IEC/EN 60068-2-30: 93% non-condensing| |Vibration resistance||IEC/EN 60068-2-6: 20 m/s² / 10 Hz - 150 Hz| |||| |Shock resistance||IEC/EN 60068-2-27: 15 g - 11 ms| |Short interruption on power line||IEC/EN 61000-4-11: 0% residual voltage, 250/300 cycles| |Weight||64 g| |Packaging||Paper<br>Compact carton<br>Corrugated carton<br>PE bags (not glued)<br>Molded cellulose pulp (e.g.-box)<br>PET pieces (recyclable)| |||| |||| |**Standards**||| |||| |Approvals / marking||CE, cULus Listed Industrial Control Equipment, CCC*| |||| |Conformity with environmental directives||2015/863/UE: RoHS<br>1907/2006: Reach| |||| |Immunity to electrostatic discharges||IEC/EN 61000-4-2: Level III (Air 8 kV / Contact 6 kV)| |Immunity to radiated, radio-frequency,<br>electromagnetic field||IEC/EN 61000-4-3:<br>Level I (1 V/m: 2.0 GHz - 2.7 GHz)<br>Level II (3 V/m: 1.4 GHz - 2.0 GHz)<br>Level III (10 V/m: 80 MHz - 1 GHz)| |Immunity to rapid transient bursts||IEC/EN 61000-4-4: Level III (direct 2 kV / Capacitive coupling clamp 1 kV)| |||| |Immunity to shock waves on power<br>supply||IEC/EN 61000-4-5: Level III (2 kV / common mode 2 kV / residual current mode 1 kV)| |Immunity to radiofrequency in common<br>mode||IEC/EN 61000-4-6: Level III (10 Vrms: 0.15 MHz - 80 MHz)| |||| |Immunity to voltage dips and breaks||IEC/EN 61000-4-11:<br>0% residual voltage, 1 cycle<br>70% residual voltage, 25/30 cycles| ©Crouzet - Technical Datasheet - 10/01/2025 - www.crouzet.com 3 Repeat Cycle Analog Timer ## **Dimensions (mm)** **==> picture [269 x 203] intentionally omitted <==** **----- Start of picture text -----**<br> 60 ±0.5<br>44 (MAX)<br>17.9 [+0.5] 0<br>23.1 ±0.25<br>fo | 3 }<br>5.5 ±0.2<br>DIN- Rail Mount 1 7 . 5 mm<br>3.5 ±0.2<br>= [L d<br>0 0.5- ±0.5 ±0.5<br>90 67.5 45<br>±0.2<br>2.5<br>**----- End of picture text -----**<br> ## **Wiring diagrams** **==> picture [119 x 193] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>+<br>A1 Y1 15<br>R<br>A2<br>hg 16 18<br>e-”~—©~—~—SS<br>A1 Y1<br>**----- End of picture text -----**<br> ©Crouzet - Technical Datasheet - 10/01/2025 - www.crouzet.com 4 Repeat Cycle Analog Timer ## **Function diagrams** **Function L: Repeat Cycle (Asymmetrical) - OFF Start** ## **Function Li: Repeat Cycle (Asymmetrical) - ON Start** **WARNING -** The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of contractual commitment. Crouzet Automatismes SAS and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products. ©Crouzet - Technical Datasheet - 10/01/2025 - www.crouzet.com 5
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →